Rheem Prestige Series 2 Stage Serial Communicating Specification Sheet

2015-04-02

: Rheem Rheem-Prestige-Series-2-Stage-Serial-Communicating-Specification-Sheet-683612 rheem-prestige-series-2-stage-serial-communicating-specification-sheet-683612 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 48

DownloadRheem Rheem-Prestige-Series-2-Stage-Serial-Communicating-Specification-Sheet-  Rheem-prestige-series-2-stage-serial-communicating-specification-sheet
Open PDF In BrowserView PDF
Air

Air Conditioners
RASL- JEC Series

Rheem Prestige Series™ Two-Stage
Air Conditioners equipped with
the Comfort Control System™
2

RASL- JEC Series
Efficiencies up to 18 SEER/14 EER
Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kW]
Cooling Capacities 25.8 to 57.2
[7.56 to 16.76 kW]
16.0

“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit
www.energystar.gov.”

• Industry’s lowest profile design: 33" maximum height
• The Comfort Control 2 System™ provides over 32+ on-board
diagnostics and fault history codes for condensing units with
single-phase compressors by detecting system and electrical
problems. The integrated diagnostics with Active Protection™
prevents compressor operation when potentially harmful
conditions are detected. Sends “Call for Service” alert notification to the thermostat to alert the homeowner of required
service.
• Serial Communication Enhanced – When installed with a
Serial Communicating Air Handler (RHPL/RHPN-HM****JC)
and user interface control (RHC-TST501CMMS) Series 500
thermostat this unit offers 4 or 2 wire installation, autoconfiguration, and diagnostic messaging with full communicating capability.
• Legacy Enabled – Unit can be conventionally wired using
24VAC with non-communicating Rheem Prestige air-handlers
or furnaces with non-communicating thermostat.
• Features a 10-year conditional unit replacement warranty and
10-year parts warranty when properly installed with a new
Rheem air handler or Rheem indoor coil with a Rheem gas
furnace. See product warranty card for additional information.

• Reliable Two-Stage operation for precise temperature control
with On-Demand dehumidification feature. When matched
with ECM gas furnace or air-handler, the system adjusts airflow to help control humidity for unsurpassed comfort in the
cooling mode.
• All controls are accessible by removing one service panel.
Removable top grille provides access to the condenser fan
motor and condenser coil.
• Attractive, louvered wrap-around jacket protects the coil
from yard hazards and weather extremes. Top grille is steel
reinforced for extra strength. Cabinet is powder painted for
all-weather protection.
• For quiet operation and improved efficiency, models feature
an ECM two-speed condenser fan motor with a 3-blade
outdoor fan.
• All models meet or exceed a 1000-hour salt spray test per
ASTM B117 Standard Practice for Operating Salt Spray
Testing Apparatus.

FORM NO. A11-211

Air

Table of Contents
RASL- JEC Series

TABLE OF CONTENTS
Model Features ..............................................................................................3
Model Number Identification ............................................................................4
Accessories....................................................................................................4
Scroll Compressor ..........................................................................................4
Performance Data ......................................................................................5-38
Electrical & Physical Data ..............................................................................39
Unit Dimensions............................................................................................40
Refrigerant Line Size Information ..............................................................41-43
Limited Warranty ..........................................................................................44

2

Air

Model Features
RASL- JEC Series

The Comfort Control 2 System ™ Features:
■

The Rheem exclusive Dual 7-Segment LED Display easily
shows system operating status codes
and diagnostic codes.
■ A Sealed Switch replaces the standard
contactor and
features optical
control and
latching mechanism. The sealed
switch prevents
infiltration of
insects and dust. A minimal switching
arc, by the optical control, offers greater
reliability. The latching mechanism consumes less power while reducing chatter.
■

The Status Indication and System Diagnostics feature
thermostat communication capability, built-in diagnostics,
current sensing and high & low pressure switch monitoring. The thermostat communication capability alerts the
homeowner to any necessary service requirements. Faster, more
accurate service is provided by the
built-in diagnostics, by providing
the HVAC professional with
dependable information. In addition,
high and low pressure-switch monitoring prevents the system from
operating outside of its normal parameters.

■

The fault recall feature will allow for the last six fault-codes
to be displayed, and will retain these codes even if power
failure occurs.
■ Built-in short-cycle protection allows the compressor to
restart easily without oil removal.
■ A 30-second minimum run-time for every compressor call
allows the oil to return to the compressor.
■ Active Protection monitors the system to prevent nuisance
lockouts and prevents compressor operation when potentially harmful conditions are detected.
■ The compressor and fan are
controlled independently,
which reduces the starting load
and light dimming.
■ A manual push-button is
offered to operate the compressor and fan for 5 seconds
to allow for an operation
check.
■ In order to save time and
money, replacement automotive fuses can be utilized
instead of replacing the entire control board.

Standard Features:
RASL- JEC Condensing Units
1. Scroll compressor is hermetically sealed and incorporates
internal high temperature motor overload protection, and
durable insulation on the motor windings. It is externally
mounted on rubber grommets to reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to
protect against excessive pressure differential.
3. All refrigerant connections are on the exterior of the unit,
located close to the ground for neat appearing installations.
4. Cabinet is constructed of powder painted galvanized
steel. The full wrap-around louvered grille protects the coil
from damage.
5. Sound Blanket-enhanced compressor sound blanket is
standard.
6. Copper tube—aluminum fin coils are used on all models.
7. The control box is located in the top corner of the cabinet
providing for easy access through a service panel.
8. Service valves are standard on all models.
9. Field connections for power and control wiring are kept
separate.
10. Every unit is factory charged and run-tested.
11. Separate compressor compartment for easy service
access.
12. Drawn, painted base pan for extra corrosion resistance and
sound reduction.
13. The RASL- JEC has a 10-year limited parts warranty, plus a
10-year conditional unit replacement warranty. Refer to the
General Terms of Limited Warranty for more details.
14. Hard Start Kits—Standard on all JEC models.
15. Control Box Cover.
16. The RASL- JEC is shipped with a liquid line filter drier, and
also features factory-installed low and high pressure
controls.

Scroll® Compressor
024 & 036 nominal capacities
— Single scroll Ultra-Tech two-stage
compressor
— Operates at 67% capacity in non
peak conditions to improve
efficiency and comfort (humidity
control)
039, 048 & 60 nominal capacities
— Dual Drive scroll compressors –
Tandem
— Operates at 50% capacity on first
compressor in non peak conditions
to improve efficiency and comfort
(humidity control)
— Compressor “A” operated by control
board “A” Compressor “B” operated
by control board “B”.

3

Air

Model I.D./Accessories/Compressor
RASL- JEC Series

Model Number Identification
R

A

S

L

RHEEM

REMOTE
CONDENSING
UNIT

18-SEER

—

024

J

EC

DESIGN
SERIES

COOLING
CAPACITY

ELECTRICAL
DESIGNATION

L = FIRST DESIGN
SERIES

025 = 24,000 BTU/HR [7.03 kW]
037 = 36,000 BTU/HR [10.55 kW]
039 = 39,000 BTU/HR [11.43 kW]
048 = 48,000 BTU/HR [14.07 kW]
060 = 60,000 BTU/HR [17.6 kW]

J = 208/230V-1-60

EC = EQUIPPED WITH
THE
COMFORT
CONTROL2 SYSTEM ™

Accessories
• Communicating 2 Wire Kit (RXME-A02)

Thermostats
200-Series *
Programmable

300-Series *
Deluxe
Programmable

500-Series *

Communicating/
Programmable

400-Series *

Special Applications/
Programmable

* Photos are representative. Actual models may vary.

For detailed thermostat match-up information,
see specification sheet form number T11-001.

Scroll® Compressor
The reliable scroll compressor is the key to efficiency for this
Rheem model. It’s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and
vibration characteristics and features tolerance to liquid refrigerant
and system contamination. The scroll compressor also has low
start torque, reducing start problems in the field. And its unique
design enables air conditioners to perform efficiently and quietly.
[ ] Designates Metric Conversions

4

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

14500 [4.2]

6100 [1.8]

575 [271]

71

2

19300 [5.7]

6500 [1.9]

825 [389]

74

1 - dehumid

12100 [3.5]

5200 [1.5]

2 - dehumid

17300 [5.1]

7300 [2.1]

1

13800 [4.0]

6200 [1.8]

2

18200 [5.3]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18200 [5.3]

6400 [1.9]

1

13800 [4.0]

6200 [1.8]

2

18200 [5.3]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18200 [5.3]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

13800 [4.0]

6200 [1.8]

2

18400 [5.4]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

13800 [4.0]

6200 [1.8]

2

18400 [5.4]

6400 [1.9]

1

14300 [4.2]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

13800 [4.0]

6200 [1.8]

2

18400 [5.4]

6400 [1.9]

1

14300 [4.2]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

13800 [4.0]

6200 [1.8]

2

18200 [5.3]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18200 [5.3]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18000 [5.3]

6400 [1.9]

1

14900 [4.4]

5900 [1.7]

2

18200 [5.3]

6400 [1.9]

1

14300 [4.2]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

14100 [4.1]

6100 [1.8]

2

18400 [5.4]

6400 [1.9]

1

13700 [4.0]

6100 [1.8]

2

17800 [5.2]

6400 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

Model Numbers
Stage
ID Coil

ID Air Mover

Rev.
5/8/2012

RCSN-H*2421 ➀

RHPN-HM2421

RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?
RGFG-07?MCK?
RGGE-06?MCK?
RGGE-07?MCK?
RGJF-06?MCK?
RGJF-07?MCK?
RCFL-H*2417

RGLE-07?AMK?

025JEC
RGPE-05?BMK?
RGPE-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROLA-070E03
RCFL-H*2417+RXMD-C06

Coil Only
RGFE-06?MCK?

RCFL-H*2617
RGFE-07?MCK?

➀ Highest sales volume tested combination required by D.O.E. test procedures.

25800 [7.6]

18

14

Sound
Rating
dB

475 [224]
675 [319]

24600 [7.2]
24600 [7.2]
24600 [7.2]
24600 [7.2]

17
17
17
17

13
13
13
13

24800 [7.3]

17

13

24800 [7.3]

17

13

24800 [7.3]
24800 [7.3]
24800 [7.3]
24800 [7.3]
24800 [7.3]
24600 [7.2]
24600 [7.2]

17
17
17.5
17
17.5
17
17

13
13
13
13
13
13
13

24400 [7.1]

16.5

13

24600 [7.2]

17

13

24800 [7.3]
24800 [7.3]

17.5
17

13
13

24200 [7.1]

15.1

12.5

25600 [7.5]

18

13

25600 [7.5]

18

13

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

[ ] Designates Metric Conversions

5

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14800 [4.3]

6000 [1.8]

2

18900 [5.5]

6500 [1.9]

1

15800 [4.6]

5800 [1.7]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14400 [4.2]

6000 [1.8]

2

18700 [5.5]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
RGFG-06?MCK?
RGFG-07?MCK?
RGGE-06?MCK?
RGGE-07?MCK?
RGJF-06?MCK?
RGJF-07?MCK?
RGLE-07?AMK?

RCFL-H*2617

RGPE-05?BMK?
RGPE-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?

025JEC
RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROLA-070E03
RCFL-H*2617+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?

RCFL-H*2621
RGFG-07?MCK?
RGGE-06?MCK?
RGGE-07?MCK?

➀ Highest sales volume tested combination required by D.O.E. test procedures.

6

25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]

18
18
18
18
18
18

13
13
13
13
13
13

25800 [7.6]

18

13

25600 [7.5]

18

13

25800 [7.6]
25600 [7.5]
25600 [7.5]
25400 [7.4]
25600 [7.5]
25800 [7.6]
25800 [7.6]

18
18
18
17.5
18
18
18

13
13
13
13
13
13
13

25200 [7.4]

15.5

12.5

25600 [7.5]

18

13

25600 [7.5]
25600 [7.5]

18
18

13
13

25600 [7.5]

18

13

25600 [7.5]

18

13

25600 [7.5]

18

13

Sound
Rating
dB

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14800 [4.3]

6000 [1.8]

2

18900 [5.5]

6500 [1.9]

1

15800 [4.6]

5800 [1.7]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14400 [4.2]

6000 [1.8]

2

18700 [5.5]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
RGJF-06?MCK?
RGJF-07?MCK?
RGLE-07?AMK?
RGPE-05?BMK?
RGPE-07?AMK?

RCFL-H*2621

RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROLA-070E03

025JEC
RCFL-H*2621+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?
RGFG-07?MCK?
RGGE-06?MCK?

RCFN-H*2417
RGGE-07?MCK?
RGJF-06?MCK?
RGJF-07?MCK?
RGLE-07?AMK?
RGPE-05?BMK?

➀ Highest sales volume tested combination required by D.O.E. test procedures.

25600 [7.5]
25600 [7.5]
25800 [7.6]
25600 [7.5]
25800 [7.6]
25600 [7.5]

18
18
18
18
18
18

13
13
13
13
13
13

25600 [7.5]

18

13

25400 [7.4]

17.5

13

25600 [7.5]
25800 [7.6]
25800 [7.6]
25200 [7.4]
25600 [7.5]
25600 [7.5]
25600 [7.5]

18
18
18
15.5
18
18
18

13
13
13
12.5
13
13
13

25600 [7.5]

18

13

25600 [7.5]

18

13

25600 [7.5]
25600 [7.5]

18
18

13
13

25600 [7.5]

18

13

25800 [7.6]

18

13

25600 [7.5]

18

13

Sound
Rating
dB

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

[ ] Designates Metric Conversions

7

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

15000 [4.4]

6000 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14800 [4.3]

6000 [1.8]

2

18900 [5.5]

6500 [1.9]

1

15800 [4.6]

5800 [1.7]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14400 [4.2]

6000 [1.8]

2

18700 [5.5]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

15000 [4.4]

6000 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19100 [5.6]

6500 [1.9]

1

14800 [4.3]

6000 [1.8]

2

18900 [5.5]

6500 [1.9]

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
RGPE-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?

RCFN-H*2417

RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROLA-070E03

RCFN-H*2417+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?

025JEC
RGFG-07?MCK?
RGGE-06?MCK?
RGGE-07?MCK?
RGJF-06?MCK?
RCFN-H*2421
RGJF-07?MCK?
RGLE-07?AMK?
RGPE-05?BMK?
RGPE-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?

➀ Highest sales volume tested combination required by D.O.E. test procedures.

8

25800 [7.6]
25600 [7.5]
25600 [7.5]
25400 [7.4]
25600 [7.5]
25800 [7.6]

18
18
18
17.5
18
18

13
13
13
13
13
13

25800 [7.6]

18

13

25200 [7.4]

15.5

12.5

25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]
25600 [7.5]

18
18
18
18
18
18
18

13
13
13
13
13
13
13

25600 [7.5]

18

13

25800 [7.6]

18

13

25600 [7.5]
25800 [7.6]

18
18

13
13

25600 [7.5]

18

13

25600 [7.5]

18

13

25400 [7.4]

17.5

13

Sound
Rating
dB

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

15800 [4.6]

5800 [1.7]

2

19100 [5.6]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14500 [4.2]

6100 [1.8]

2

19300 [5.7]

6500 [1.9]

1

14400 [4.2]

6000 [1.8]

2

18700 [5.5]

6500 [1.9]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

14700 [4.3]

5700 [1.7]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

14700 [4.3]

5700 [1.7]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

14700 [4.3]

5700 [1.7]

2

20300 [5.9]

5700 [1.7]

1

14700 [4.3]

5700 [1.7]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20500 [6.0]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20000 [5.9]

5800 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

14700 [4.3]

5700 [1.7]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20100 [5.9]

5700 [1.7]

1

15900 [4.7]

5300 [1.6]

2

20300 [5.9]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20500 [6.0]

5700 [1.7]

1

15000 [4.4]

5600 [1.6]

2

20500 [6.0]

5700 [1.7]

1

14600 [4.3]

5600 [1.6]

2

19900 [5.8]

5700 [1.7]

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
RGTM-06?MAE?

RCFN-H*2421

ROCA-070E03
ROLA-070E03

RCFN-H*2421+RXMD-C06

Coil Only
RBHM-17J
RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?
RGFG-07?MCK?
RGJF-06?MCK?
RGJF-07?MCK?

025JEC
RGPE-05?BMK?
RCQD-2417

RGPE-07?AMK?
RGPR-05?BMK?
RGPR-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROLA-070E03

RCQD-2417+RXMD-C06

Coil Only

➀ Highest sales volume tested combination required by D.O.E. test procedures.

25600 [7.5]
25800 [7.6]
25800 [7.6]
25200 [7.4]
26000 [7.6]
26000 [7.6]

18
18
18
15.5
18
18

13
13
13
12.5
13
13

26000 [7.6]

18

13

26000 [7.6]

18

13

26000 [7.6]
26000 [7.6]
26000 [7.6]
26000 [7.6]
26200 [7.7]
25800 [7.6]
26000 [7.6]

18
18
18
18
18
17.5
18

13
13
13
13
13
13
13

26000 [7.6]

17.5

13

26000 [7.6]

18

13

25800 [7.6]
26000 [7.6]

17.5
18

13
13

26200 [7.7]

18

13

26200 [7.7]

18

13

25600 [7.5]

15.5

13

Sound
Rating
dB

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

575 [271]

71

800 [378]

74

600 [283]

71

850 [401]

74

625 [295]

71

825 [389]

74

575 [271]

71

800 [378]

74

575 [271]

71

800 [378]

74

625 [295]

71

825 [389]

74

600 [283]

71

775 [366]

74

600 [283]

71

800 [378]

74

575 [271]

71

800 [378]

74

600 [283]

71

825 [389]

74

625 [295]

71

850 [401]

74

750 [354]

71

825 [389]

74

600 [283]

71

800 [378]

74

600 [283]

71

800 [378]

74

625 [295]

71

825 [389]

74

[ ] Designates Metric Conversions

9

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

ID Air Mover

Rev.
5/8/2012

RCSN-H*3624 ➀

RHPN-HM3624

RGFE-06?MCK?
RGFE-07?MCK?
RGFG-06?MCK?
RGFG-07?MCK?
RGGE-06?MCK?
RGGE-07?MCK?
RGJF-06?MCK?
RGJF-07?MCK?
RGLE-07?AMK?
037JEC
RGLR-07?AMK?
RCFL-H*3617
RGPE-05?BMK?
RGPE-07?AMK?
RGPR-05?BMK?
RGPR-07?AMK?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGTM-06?MAE?
ROCA-070E03
ROCA-070E04

Sound
Rating
dB

1

22300 [6.5]

8500 [2.5]

925 [437]

69

2

27900 [8.2]

10600 [3.1]

1125 [531]

72

1 - dehumid

19100 [5.6]

7100 [2.1]

2 - dehumid

25800 [7.6]

11200 [3.3]

1

18800 [5.5]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

18800 [5.5]

9200 [2.7]

2

23800 [7.0]

10800 [3.2]

1

18800 [5.5]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

18400 [5.4]

9400 [2.8]

2

22300 [6.5]

11700 [3.4]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

24000 [7.0]

10800 [3.2]

1

19100 [5.6]

9100 [2.7]

2

23700 [6.9]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19100 [5.6]

9100 [2.7]

2

23700 [6.9]

10900 [3.2]

1

18300 [5.4]

9500 [2.8]

2

22300 [6.5]

11700 [3.4]

1

18400 [5.4]

9400 [2.8]

2

22200 [6.5]

11600 [3.4]

1

19300 [5.7]

9100 [2.7]

2

22600 [6.6]

11600 [3.4]

1

18600 [5.4]

9400 [2.8]

2

22500 [6.6]

11700 [3.4]

1

18600 [5.4]

9400 [2.8]

2

22500 [6.6]

11700 [3.4]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

10

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

38500 [11.3]

18

14

750 [354]
950 [448]

34600 [10.1]
34600 [10.1]
34600 [10.1]
34000 [10.0]

15
15
15
15.5

11.5
11
11.5
12

34800 [10.2]

15.5

11.5

34600 [10.1]

15.5

11.5

34800 [10.2]
34600 [10.1]
34800 [10.2]
34800 [10.2]
34800 [10.2]
34800 [10.2]
34600 [10.1]

15.5
15.5
15.5
15.5
15.5
15.5
15

11.5
11.5
12
12
11.5
11.5
11.5

34800 [10.2]

15.5

12

34600 [10.1]

15

11.5

34000 [10.0]
33800 [9.9]

15.5
15

12
11.5

34200 [10.0]

15.5

12

34200 [10.0]

16

12.5

34200 [10.0]

16

12.5

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

800 [378]

69

1000 [472]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

775 [366]

69

1000 [472]

72

800 [378]

69

1025 [484]

72

900 [425]

69

1025 [484]

72

800 [378]

69

1000 [472]

72

800 [378]

69

1000 [472]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
ROLA-070E03

RCFL-H*3617
ROLA-070E04
RCFL-H*3617+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?
RGFG-10?ZCM?

037JEC
RGGE-06?MCK?
RCFL-H*3621

RGGE-07?MCK?
RGGE-09?ZCM?
RGGE-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGLE-07?AMK?
RGLE-07?BRQ?
RGLE-10?BRM?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

19500 [5.7]

9100 [2.7]

2

24000 [7.0]

11000 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24000 [7.0]

11000 [3.2]

1

18900 [5.5]

9100 [2.7]

2

23200 [6.8]

11200 [3.3]

1

19000 [5.6]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23800 [7.0]

10800 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24100 [7.1]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24200 [7.1]

10800 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23700 [6.9]

10900 [3.2]

1

18400 [5.4]

9400 [2.8]

2

22300 [6.5]

11700 [3.4]

1

19000 [5.6]

9200 [2.7]

2

24100 [7.1]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24100 [7.1]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24400 [7.1]

10800 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24100 [7.1]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24400 [7.1]

10800 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24100 [7.1]

10900 [3.2]

1

19000 [5.6]

9200 [2.7]

2

24100 [7.1]

10900 [3.2]

1

18300 [5.4]

9500 [2.8]

2

22800 [6.7]

11600 [3.4]

1

19200 [5.6]

9200 [2.7]

2

24300 [7.1]

10900 [3.2]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

35000 [10.3]

16

12

35000 [10.3]

16

12

34400 [10.1]

14

11.5

34600 [10.1]
34600 [10.1]
35000 [10.3]

15
15
16

11.5
11
12

35000 [10.3]

16

12

34600 [10.1]

15

11.5

34000 [10.0]
35000 [10.3]
35000 [10.3]
34800 [10.2]
34800 [10.2]
35200 [10.3]
35000 [10.3]

15.5
16
16
15.5
15.5
16
16

12
12
12
11.5
11.5
12
12

34800 [10.2]

15.5

11.5

34800 [10.2]

15.5

11.5

35200 [10.3]
35000 [10.3]

16
16

12
12

35000 [10.3]

15.5

12

34400 [10.1]

16

12.5

35200 [10.3]

16

12.5

Sound
Rating
dB

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

925 [437]

69

1075 [507]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

800 [378]

69

1000 [472]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

775 [366]

69

1025 [484]

72

875 [413]

69

1200 [566]

72

[ ] Designates Metric Conversions

11

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
RGLR-07?AMK?
RGLR-07?BRQ?
RGLR-10?BRM?
RGPE-05?BMK?
RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPR-05?BMK?
RGPR-07?AMK?
RGPR-07?BRQ?
RGPR-10?BRM?

037JEC

RCFL-H*3621
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGTM-06?MAE?
RGTM-07?RBG?
RGTM-09?ZAJ?
ROCA-070E03
ROCA-070E04

1

19500 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24400 [7.1]

10800 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24300 [7.1]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24200 [7.1]

10800 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24600 [7.2]

10800 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24600 [7.2]

10800 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23700 [6.9]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

23900 [7.0]

10900 [3.2]

1

19200 [5.6]

9200 [2.7]

2

24300 [7.1]

10900 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24400 [7.1]

10800 [3.2]

1

19100 [5.6]

9100 [2.7]

2

23700 [6.9]

10900 [3.2]

1

18300 [5.4]

9500 [2.8]

2

22300 [6.5]

11700 [3.4]

1

18400 [5.4]

9400 [2.8]

2

22200 [6.5]

11600 [3.4]

1

18700 [5.5]

9300 [2.7]

2

23500 [6.9]

10900 [3.2]

1

19300 [5.7]

9100 [2.7]

2

24200 [7.1]

10800 [3.2]

1

19000 [5.6]

9200 [2.7]

2

23400 [6.9]

11200 [3.3]

1

19300 [5.7]

9100 [2.7]

2

22600 [6.6]

11600 [3.4]

1

18600 [5.4]

9400 [2.8]

2

23100 [6.8]

11500 [3.4]

1

19900 [5.8]

8900 [2.6]

2

24400 [7.1]

10800 [3.2]

1

18600 [5.4]

9400 [2.8]

2

22500 [6.6]

11700 [3.4]

1

18600 [5.4]

9400 [2.8]

2

22500 [6.6]

11700 [3.4]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

12

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]
34800 [10.2]

16

12

35200 [10.3]

16

12.5

35200 [10.3]

16

12.5

34800 [10.2]
35000 [10.3]
35400 [10.4]

15.5
15.5
16

11.5
12
12.5

35400 [10.4]

16

12.5

34600 [10.1]

15

11.5

34800 [10.2]
35200 [10.3]
35200 [10.3]
34600 [10.1]
34000 [10.0]
33800 [9.9]
34400 [10.1]

15.5
16
16
15
15.5
15.5
15

12
12.5
12
11.5
12
11.5
11

35000 [10.3]

15.5

12

34600 [10.1]

15.5

12

34200 [10.0]
34600 [10.1]

15.5
16

12
12.5

35200 [10.3]

16

12

34200 [10.0]

16

12.5

34200 [10.0]

16

12.5

Sound
Rating
dB

925 [437]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

775 [366]

69

1000 [472]

72

800 [378]

69

1025 [484]

72

850 [401]

69

1200 [566]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

900 [425]

69

1025 [484]

72

800 [378]

69

1050 [495]

72

975 [460]

69

1225 [578]

72

800 [378]

69

1000 [472]

72

800 [378]

69

1000 [472]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover
ROLA-070E03

RCFL-H*3621

ROLA-070E04
ROLA-115E05

RCFL-H*3621+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?

037JEC
RGFG-10?ZCM?
RGGE-06?MCK?
RCFL-H*3821
RGGE-07?MCK?
RGGE-09?ZCM?
RGGE-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGLE-07?AMK?
RGLE-07?BRQ?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

19500 [5.7]

9100 [2.7]

2

24000 [7.0]

11000 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24000 [7.0]

11000 [3.2]

1

19500 [5.7]

9100 [2.7]

2

24300 [7.1]

10900 [3.2]

1

18900 [5.5]

9100 [2.7]

2

23200 [6.8]

11200 [3.3]

1

18900 [5.5]

9700 [2.8]

2

24200 [7.1]

11200 [3.3]

1

18900 [5.5]

9700 [2.8]

2

24300 [7.1]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24700 [7.2]

11100 [3.3]

1

18900 [5.5]

9700 [2.8]

2

24200 [7.1]

11200 [3.3]

1

18500 [5.4]

9900 [2.9]

2

22800 [6.7]

12000 [3.5]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24400 [7.1]

11200 [3.3]

1

18900 [5.5]

9700 [2.8]

2

24200 [7.1]

11200 [3.3]

1

20200 [5.9]

9200 [2.7]

2

25000 [7.3]

11000 [3.2]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24400 [7.1]

11200 [3.3]

1

18900 [5.5]

9700 [2.8]

2

24200 [7.1]

11200 [3.3]

1

20200 [5.9]

9200 [2.7]

2

25000 [7.3]

11000 [3.2]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24400 [7.1]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

35000 [10.3]

16

12

35000 [10.3]

16

12

35200 [10.3]

16

12.5

34400 [10.1]
35400 [10.4]
35400 [10.4]

14
15.5
15.5

11.5
12
11.5

35800 [10.5]

16

12.5

35800 [10.5]

16.5

12.5

35400 [10.4]
34800 [10.2]
35800 [10.5]
35800 [10.5]
35600 [10.4]
35400 [10.4]
36000 [10.5]

15.5
16
16
16
16
15.5
16

12
12.5
12.5
12.5
12
12
12.5

35800 [10.5]

16

12.5

35600 [10.4]

16

12

35400 [10.4]
36000 [10.5]

15.5
16

12
12.5

35800 [10.5]

16

12.5

35600 [10.4]

16

12.5

36000 [10.5]

16.5

13

Sound
Rating
dB

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

800 [378]

69

1000 [472]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

[ ] Designates Metric Conversions

13

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGLE-10?BRM?
RGLR-07?AMK?
RGLR-07?BRQ?
RGLR-10?BRM?
RGPE-05?BMK?
RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPR-05?BMK?
RGPR-07?AMK?
RGPR-07?BRQ?

037JEC

RCFL-H*3821
RGPR-10?BRM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGTM-06?MAE?
RGTM-07?RBG?
RGTM-09?ZAJ?
ROCA-070E03

1

19300 [5.7]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24400 [7.1]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24400 [7.1]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24700 [7.2]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

25100 [7.4]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

25100 [7.4]

11100 [3.3]

1

19300 [5.7]

9500 [2.8]

2

24200 [7.1]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24400 [7.1]

11200 [3.3]

1

19300 [5.7]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19300 [5.7]

9500 [2.8]

2

24000 [7.0]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

23900 [7.0]

11300 [3.3]

1

18500 [5.4]

9900 [2.9]

2

22700 [6.7]

11900 [3.5]

1

17600 [5.2]

10200 [3.0]

2

22300 [6.5]

12100 [3.5]

1

19500 [5.7]

9500 [2.8]

2

24700 [7.2]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

23900 [7.0]

11500 [3.4]

1

19500 [5.7]

9500 [2.8]

2

23100 [6.8]

11900 [3.5]

1

19500 [5.7]

9500 [2.8]

2

25300 [7.4]

10900 [3.2]

1

20000 [5.9]

9400 [2.8]

2

24900 [7.3]

11100 [3.3]

1

20100 [5.9]

9300 [2.7]

2

24600 [7.2]

11200 [3.3]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

14

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

36000 [10.5]

16.5

13

35600 [10.4]

16

12.5

36000 [10.5]

16.5

13

36000 [10.5]
35600 [10.4]
35800 [10.5]

16.5
16
16

13
12
12.5

36200 [10.6]

16.5

13

36200 [10.6]

16.5

13

35400 [10.4]
35600 [10.4]
36000 [10.5]
36000 [10.5]
35200 [10.3]
35200 [10.3]
34600 [10.1]

15.5
16
16.5
16.5
15.5
15.5
15.5

12
12.5
13
12.5
11.5
11.5
12

34400 [10.1]

16

12

35800 [10.5]

16

12

35400 [10.4]
35000 [10.3]

16
16

12.5
12.5

36200 [10.6]

16

12.5

36000 [10.5]

16

12.5

35800 [10.5]

16

12.5

Sound
Rating
dB

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

800 [378]

69

1025 [484]

72

700 [330]

69

975 [460]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

900 [425]

69

1025 [484]

72

950 [448]

69

1275 [602]

72

975 [460]

69

1225 [578]

72

1000 [472]

69

1200 [566]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

ROCA-070E04
ROLA-070E03
RCFL-H*3821
ROLA-070E04
ROLA-115E05
RCFL-H*3821+RXMD-C06

Coil Only
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?

037JEC
RGGE-09?ZCM?
RGGE-10?ZCM?
RCFL-H*3824

RGGE-12?RCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-07?BRQ?
RGLE-10?BRM?
RGLE-12?ARM?
RGLR-07?BRQ?
RGLR-10?BRM?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

20100 [5.9]

9300 [2.7]

2

24600 [7.2]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24500 [7.2]

11300 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24500 [7.2]

11300 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24800 [7.3]

11200 [3.3]

1

18900 [5.5]

9500 [2.8]

2

23500 [6.9]

11500 [3.4]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24700 [7.2]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24900 [7.3]

11100 [3.3]

1

20200 [5.9]

9200 [2.7]

2

25000 [7.3]

11000 [3.2]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

20200 [5.9]

9200 [2.7]

2

25000 [7.3]

11000 [3.2]

1

19100 [5.6]

9700 [2.8]

2

24600 [7.2]

11200 [3.3]

1

19300 [5.7]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19300 [5.7]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

25100 [7.4]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24800 [7.3]

11200 [3.3]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

35800 [10.5]

16

12.5

35800 [10.5]

16.5

12.5

35800 [10.5]

16.5

12.5

36000 [10.5]
35000 [10.3]
35800 [10.5]

16.5
14
16

13
11.5
12.5

35800 [10.5]

16.5

12.5

36000 [10.5]

16.5

12.5

35800 [10.5]
35800 [10.5]
36000 [10.5]
36000 [10.5]
35800 [10.5]
36000 [10.5]
36000 [10.5]

16
16
16.5
16
16
16.5
16

12.5
12.5
12.5
12.5
12.5
13
12.5

35800 [10.5]

16

12.5

36000 [10.5]

16.5

13

36000 [10.5]
36000 [10.5]

16.5
16.5

13
13

36200 [10.6]

16.5

13

36000 [10.5]

16.5

13

36000 [10.5]

16.5

13

Sound
Rating
dB

1000 [472]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

[ ] Designates Metric Conversions

15

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGLR-12?ARM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGPR-07?BRQ?
RGPR-10?BRM?
RGPR-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RCFL-H*3824

RGRM-10?ZAJ?
RGRM-12?RAJ?

037JEC
RGTM-07?RBG?
RGTM-09?ZAJ?
RGTM-10?RBJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05
RCFL-H*3824+RXMD-C06

Coil Only
RGFE-06?MCK?

RCFN-H*3624
RGFE-07?MCK?

1

20300 [5.9]

9300 [2.7]

2

25100 [7.4]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19300 [5.7]

9700 [2.8]

2

24800 [7.3]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

20100 [5.9]

9300 [2.7]

2

25200 [7.4]

11000 [3.2]

1

18900 [5.5]

9700 [2.8]

2

24000 [7.0]

11200 [3.3]

1

19500 [5.7]

9500 [2.8]

2

24700 [7.2]

11100 [3.3]

1

19100 [5.6]

9700 [2.8]

2

23700 [6.9]

11500 [3.4]

1

19700 [5.8]

9500 [2.8]

2

24900 [7.3]

11100 [3.3]

1

19500 [5.7]

9500 [2.8]

2

25300 [7.4]

10900 [3.2]

1

20000 [5.9]

9400 [2.8]

2

24900 [7.3]

11100 [3.3]

1

20000 [5.9]

9400 [2.8]

2

24900 [7.3]

11100 [3.3]

1

20100 [5.9]

9300 [2.7]

2

24400 [7.1]

11200 [3.3]

1

20100 [5.9]

9300 [2.7]

2

24400 [7.1]

11200 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24500 [7.2]

11300 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24500 [7.2]

11300 [3.3]

1

19700 [5.8]

9500 [2.8]

2

24800 [7.3]

11200 [3.3]

1

18900 [5.5]

9500 [2.8]

2

23500 [6.9]

11500 [3.4]

1

21500 [6.3]

8700 [2.5]

2

27800 [8.1]

10200 [3.0]

1

21500 [6.3]

8700 [2.5]

2

27900 [8.2]

10100 [3.0]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

16

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

36200 [10.6]

16.5

13

36000 [10.5]

16.5

13

36000 [10.5]

16.5

13

36000 [10.5]
36000 [10.5]
36000 [10.5]

16.5
16.5
16.5

13
13
12.5

36200 [10.6]

16.5

13

35200 [10.3]

15.5

11.5

35800 [10.5]
35200 [10.3]
36000 [10.5]
36200 [10.6]
36000 [10.5]
36000 [10.5]
35600 [10.4]

15.5
16
16
16
16
16.5
16

12
12.5
12.5
12.5
12.5
13
12.5

35600 [10.4]

16

12.5

35800 [10.5]

16.5

12.5

35800 [10.5]
36000 [10.5]

16.5
16.5

12.5
13

35000 [10.3]

14

11.5

38000 [11.1]

16.5

12.5

38000 [11.1]

16.5

12.5

Sound
Rating
dB

1000 [472]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

1000 [472]

69

1250 [590]

72

850 [401]

69

1200 [566]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

925 [437]

69

1225 [578]

72

950 [448]

69

1275 [602]

72

975 [460]

69

1225 [578]

72

975 [460]

69

1225 [578]

72

1000 [472]

69

1200 [566]

72

1000 [472]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGGE-06?MCK?
RGGE-07?MCK?
RGGE-09?ZCM?

037JEC

RCFN-H*3624
RGGE-10?ZCM?
RGGE-12?RCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-07?AMK?
RGLE-07?BRQ?
RGLE-10?BRM?
RGLE-12?ARM?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

23100 [6.8]

8100 [2.4]

2

28600 [8.4]

9900 [2.9]

1

21500 [6.3]

8700 [2.5]

2

27800 [8.1]

10200 [3.0]

1

22600 [6.6]

8200 [2.4]

2

27900 [8.2]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

28300 [8.3]

10200 [3.0]

1

23100 [6.8]

8100 [2.4]

2

28600 [8.4]

9900 [2.9]

1

22100 [6.5]

8500 [2.5]

2

27800 [8.1]

10200 [3.0]

1

21500 [6.3]

8700 [2.5]

2

27800 [8.1]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28400 [8.3]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

27800 [8.1]

10200 [3.0]

1

21500 [6.3]

8700 [2.5]

2

27800 [8.1]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28400 [8.3]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28900 [8.5]

10100 [3.0]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

38000 [11.1]
38000 [11.1]
38500 [11.3]

16.5
16
17.5

12.5
12.5
13

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

38000 [11.1]
38000 [11.1]
38500 [11.3]
38500 [11.3]
38500 [11.3]
38000 [11.1]
38000 [11.1]

17
17
17.5
17.5
18
17
17

13
13
13
13
13
13
13

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

38500 [11.3]
38500 [11.3]

18
17

13
13

38500 [11.3]

18

13

38500 [11.3]

18

13

39000 [11.4]

18

13

Sound
Rating
dB

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

1000 [472]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

1025 [484]

69

1250 [590]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

[ ] Designates Metric Conversions

17

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGLR-07?AMK?
RGLR-07?BRQ?
RGLR-10?BRM?
RGLR-12?ARM?
RGPE-05?BMK?
RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGPR-05?BMK?
RGPR-07?AMK?

037JEC

RCFN-H*3624
RGPR-07?BRQ?
RGPR-10?BRM?
RGPR-12?ARM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
RGTM-06?MAE?

1

22100 [6.5]

8500 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28300 [8.3]

10200 [3.0]

1

23000 [6.7]

8200 [2.4]

2

28900 [8.5]

10100 [3.0]

1

22100 [6.5]

8500 [2.5]

2

27800 [8.1]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21900 [6.4]

8500 [2.5]

2

27800 [8.1]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21700 [6.4]

8700 [2.5]

2

28300 [8.3]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

23000 [6.7]

8200 [2.4]

2

29100 [8.5]

9900 [2.9]

1

21900 [6.4]

8500 [2.5]

2

27600 [8.1]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

27500 [8.1]

10300 [3.0]

1

21700 [6.4]

8500 [2.5]

2

27700 [8.1]

10100 [3.0]

1

21400 [6.3]

8800 [2.6]

2

27600 [8.1]

10200 [3.0]

1

22100 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

21700 [6.4]

8700 [2.5]

2

27200 [8.0]

10600 [3.1]

1

22300 [6.5]

8500 [2.5]

2

28400 [8.3]

10100 [3.0]

1

23200 [6.8]

8000 [2.3]

2

27900 [8.2]

10100 [3.0]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

18

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

38500 [11.3]

17.5

13

38500 [11.3]

18

13

38500 [11.3]

17.5

13

39000 [11.4]
38000 [11.1]
38500 [11.3]

18
17
17.5

13
13
13

38500 [11.3]

18

13

38500 [11.3]

18

13

38500 [11.3]
38000 [11.1]
38500 [11.3]
38500 [11.3]
38500 [11.3]
39000 [11.4]
37800 [11.1]

18
16.5
17
18
17.5
17.5
16.5

13
12.5
13
13
13
13
12.5

37800 [11.1]

17

12.5

37800 [11.1]

16

12

37800 [11.1]
38500 [11.3]

16.5
17

12.5
13

37800 [11.1]

17.5

13

38500 [11.3]

17.5

13

38000 [11.1]

16.5

12.5

Sound
Rating
dB

925 [437]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

925 [437]

69

1200 [566]

72

1000 [472]

69

1225 [578]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

1000 [472]

69

1250 [590]

72

925 [437]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

950 [448]

69

1225 [578]

72

850 [401]

69

1200 [566]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

925 [437]

69

1225 [578]

72

1075 [507]

69

1225 [578]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGTM-07?RBG?
RGTM-09?ZAJ?
RGTM-10?RBJ?
ROCA-070E03
RCFN-H*3624
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05
RCFN-H*3624+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?

037JEC
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFG-06?MCK?
RGFG-07?MCK?
RCQD-3621

RGFG-09?ZCM?
RGFG-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGPE-05?BMK?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

22100 [6.5]

8500 [2.5]

2

29200 [8.6]

9800 [2.9]

1

22700 [6.7]

8300 [2.4]

2

28400 [8.3]

10100 [3.0]

1

22700 [6.7]

8300 [2.4]

2

28400 [8.3]

10100 [3.0]

1

22800 [6.7]

8200 [2.4]

2

28300 [8.3]

10200 [3.0]

1

22800 [6.7]

8200 [2.4]

2

28300 [8.3]

10200 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28200 [8.3]

10300 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28200 [8.3]

10300 [3.0]

1

22300 [6.5]

8500 [2.5]

2

28300 [8.3]

10200 [3.0]

1

21500 [6.3]

8500 [2.5]

2

27000 [7.9]

10600 [3.1]

1

21100 [6.2]

8500 [2.5]

2

27200 [8.0]

10000 [2.9]

1

18200 [5.3]

9600 [2.8]

2

25800 [7.6]

10800 [3.2]

1

21100 [6.2]

8500 [2.5]

2

27600 [8.1]

10000 [2.9]

1

21600 [6.3]

8400 [2.5]

2

27700 [8.1]

9900 [2.9]

1

21100 [6.2]

8500 [2.5]

2

27200 [8.0]

10000 [2.9]

1

21900 [6.4]

8100 [2.4]

2

27300 [8.0]

9900 [2.9]

1

21100 [6.2]

8500 [2.5]

2

27600 [8.1]

10000 [2.9]

1

21600 [6.3]

8400 [2.5]

2

27600 [8.1]

10000 [2.9]

1

17900 [5.2]

9700 [2.8]

2

26000 [7.6]

10800 [3.2]

1

17900 [5.2]

9700 [2.8]

2

26000 [7.6]

10800 [3.2]

1

22400 [6.6]

8000 [2.3]

2

28000 [8.2]

9800 [2.9]

1

21100 [6.2]

8500 [2.5]

2

27600 [8.1]

10000 [2.9]

1

21400 [6.3]

8400 [2.5]

2

27400 [8.0]

10000 [2.9]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

39000 [11.4]

17.5

13

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

38500 [11.3]
38500 [11.3]
38500 [11.3]

17
17
17.5

13
13
13

38500 [11.3]

17.5

13

38500 [11.3]

17.5

13

37600 [11.0]
37200 [10.9]
36600 [10.7]
37600 [11.0]
37600 [11.0]
37200 [10.9]
37200 [10.9]

15
16.5
17
17
17
16.5
16

12.5
12.5
13
13
13
12.5
12.5

37600 [11.0]

17

13

37600 [11.0]

17

13

36800 [10.8]
36800 [10.8]

17
17

13
13

37800 [11.1]

17

13

37600 [11.0]

17

13

37400 [11.0]

17

12.5

Sound
Rating
dB

950 [448]

69

1275 [602]

72

975 [460]

69

1225 [578]

72

975 [460]

69

1225 [578]

72

1000 [472]

69

1200 [566]

72

1000 [472]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

875 [413]

69

1200 [566]

72

500 [236]

69

1025 [484]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

1000 [472]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

475 [224]

69

1025 [484]

72

475 [224]

69

1025 [484]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

[ ] Designates Metric Conversions

19

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPR-05?BMK?
RGPR-07?AMK?
RGPR-07?BRQ?
RGPR-10?BRM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RCQD-3621

RGRM-07?YBG?

037JEC
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGTM-06?MAE?
RGTM-07?RBG?
RGTM-09?ZAJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05
RCQD-3621+RXMD-C06

Coil Only

1

21600 [6.3]

8400 [2.5]

2

27700 [8.1]

9900 [2.9]

1

20000 [5.9]

9000 [2.6]

2

26200 [7.7]

10800 [3.2]

1

21600 [6.3]

8400 [2.5]

2

28100 [8.2]

9900 [2.9]

1

21400 [6.3]

8400 [2.5]

2

27200 [8.0]

10000 [2.9]

1

21600 [6.3]

8400 [2.5]

2

27400 [8.0]

10000 [2.9]

1

21300 [6.2]

8500 [2.5]

2

27800 [8.1]

10000 [2.9]

1

21600 [6.3]

8400 [2.5]

2

27900 [8.2]

9900 [2.9]

1

20100 [5.9]

8900 [2.6]

2

25800 [7.6]

10800 [3.2]

1

21400 [6.3]

8400 [2.5]

2

26900 [7.9]

10100 [3.0]

1

20400 [6.0]

8800 [2.6]

2

25600 [7.5]

10800 [3.2]

1

20800 [6.1]

8600 [2.5]

2

27000 [7.9]

10000 [2.9]

1

21400 [6.3]

8400 [2.5]

2

27700 [8.1]

9900 [2.9]

1

21100 [6.2]

8500 [2.5]

2

26800 [7.9]

10400 [3.0]

1

21400 [6.3]

8400 [2.5]

2

25800 [7.6]

10800 [3.2]

1

21600 [6.3]

8400 [2.5]

2

28300 [8.3]

9700 [2.8]

1

22000 [6.4]

8200 [2.4]

2

27900 [8.2]

9900 [2.9]

1

22100 [6.5]

8100 [2.4]

2

27600 [8.1]

10000 [2.9]

1

22100 [6.5]

8100 [2.4]

2

27600 [8.1]

10000 [2.9]

1

21600 [6.3]

8400 [2.5]

2

27500 [8.1]

10100 [3.0]

1

21600 [6.3]

8400 [2.5]

2

27500 [8.1]

10100 [3.0]

1

21600 [6.3]

8400 [2.5]

2

27800 [8.1]

10000 [2.9]

1

20800 [6.1]

8400 [2.5]

2

26400 [7.7]

10400 [3.0]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

20

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

37600 [11.0]

17

13

37000 [10.8]

17.5

13

38000 [11.1]

17.5

13

37200 [10.9]
37400 [11.0]
37800 [11.1]

16
17
17.5

12.5
13
13

37800 [11.1]

17

13

36600 [10.7]

17

12.5

37000 [10.8]
36400 [10.7]
37000 [10.8]
37600 [11.0]
37200 [10.9]
36600 [10.7]
38000 [11.1]

16.5
16.5
16.5
16.5
17
17
17

12
12.5
12
13
13
13
13

37800 [11.1]

17

13

37600 [11.0]

16.5

13

37600 [11.0]
37600 [11.0]

16.5
17

13
13

37600 [11.0]

17

13

37800 [11.1]

17

13

36800 [10.8]

14.5

12

Sound
Rating
dB

900 [425]

69

1225 [578]

72

725 [342]

69

1025 [484]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

750 [354]

69

1025 [484]

72

900 [425]

69

1175 [554]

72

800 [378]

69

1025 [484]

72

850 [401]

69

1200 [566]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

900 [425]

69

1025 [484]

72

950 [448]

69

1275 [602]

72

975 [460]

69

1225 [578]

72

1000 [472]

69

1200 [566]

72

1000 [472]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RBHM-24J
RBHN-24J
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?

037JEC

RCQD-3624
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGPR-07?BRQ?
RGPR-10?BRM?
RGPR-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
RGTM-07?RBG?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

22100 [6.5]

8700 [2.5]

2

27600 [8.1]

10000 [2.9]

1

22100 [6.5]

8700 [2.5]

2

28000 [8.2]

10000 [2.9]

1

21500 [6.3]

8900 [2.6]

2

27500 [8.1]

9900 [2.9]

1

22100 [6.5]

8700 [2.5]

2

27900 [8.2]

9700 [2.8]

1

22900 [6.7]

8300 [2.4]

2

28200 [8.3]

9600 [2.8]

1

21500 [6.3]

8900 [2.6]

2

27500 [8.1]

9900 [2.9]

1

21900 [6.4]

8700 [2.5]

2

27500 [8.1]

9900 [2.9]

1

21500 [6.3]

8900 [2.6]

2

28100 [8.2]

9700 [2.8]

1

22900 [6.7]

8300 [2.4]

2

28200 [8.3]

9600 [2.8]

1

21500 [6.3]

8900 [2.6]

2

27500 [8.1]

9900 [2.9]

1

21500 [6.3]

8900 [2.6]

2

27900 [8.2]

9900 [2.9]

1

22100 [6.5]

8700 [2.5]

2

28100 [8.2]

9700 [2.8]

1

22100 [6.5]

8700 [2.5]

2

28100 [8.2]

9700 [2.8]

1

21500 [6.3]

8900 [2.6]

2

27900 [8.2]

9900 [2.9]

1

21500 [6.3]

8900 [2.6]

2

27700 [8.1]

9900 [2.9]

1

21900 [6.4]

8700 [2.5]

2

28100 [8.2]

9700 [2.8]

1

22800 [6.7]

8400 [2.5]

2

28400 [8.3]

9600 [2.8]

1

21000 [6.2]

9000 [2.6]

2

26900 [7.9]

9900 [2.9]

1

21900 [6.4]

8700 [2.5]

2

27700 [8.1]

9700 [2.8]

1

21500 [6.3]

8900 [2.6]

2

26800 [7.9]

10200 [3.0]

1

22100 [6.5]

8700 [2.5]

2

27900 [8.2]

9700 [2.8]

1

21900 [6.4]

8700 [2.5]

2

28300 [8.3]

9500 [2.8]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

37600 [11.0]

17.5

13

38000 [11.1]

17.5

13

37400 [11.0]

17

13

37600 [11.0]
37800 [11.1]
37400 [11.0]

17
17
17

13
13
13

37400 [11.0]

17

13

37800 [11.1]

17

13

37800 [11.1]
37400 [11.0]
37800 [11.1]
37800 [11.1]
37800 [11.1]
37800 [11.1]
37600 [11.0]

17
17
17.5
17.5
17.5
17.5
17.5

13
13
13
13
13
13
13

37800 [11.1]

17

13

38000 [11.1]

17

13

36800 [10.8]
37400 [11.0]

16
16.5

12
13

37000 [10.8]

17

13

37600 [11.0]

17

13

37800 [11.1]

17

13

Sound
Rating
dB

900 [425]

69

1175 [554]

72

925 [437]

69

1175 [554]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1200 [566]

72

875 [413]

69

1225 [578]

72

1025 [484]

69

1250 [590]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

900 [425]

69

1225 [578]

72

900 [425]

69

1225 [578]

72

875 [413]

69

1200 [566]

72

875 [413]

69

1200 [566]

72

925 [437]

69

1225 [578]

72

1000 [472]

69

1250 [590]

72

850 [401]

69

1200 [566]

72

950 [448]

69

1225 [578]

72

875 [413]

69

1150 [543]

72

925 [437]

69

1225 [578]

72

950 [448]

69

1275 [602]

72

[ ] Designates Metric Conversions

21

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGTM-09?ZAJ?
RGTM-10?RBJ?
ROCA-070E03
RCQD-3624

ROCA-070E04
ROLA-070E03

037JEC
ROLA-070E04
ROLA-115E05
RCQD-3624+RXMD-C06
RCSL-H*3621
RCSL-H*3821

RCSN-H*3624 ➀

Coil Only
RHPL-HM3621
RHPL-HM3821

RHPN-HM3624

RGFG-06?MCK?
RGFG-07?MCK?
RGGE-06?MCK?
RGJF-06?MCK?
039JEC
RGJF-07?MCK?
RCFL-H*3617
RGLE-07?AMK?
RGPE-05?BMK?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?

1

22500 [6.6]

8500 [2.5]

2

27900 [8.2]

9700 [2.8]

1

22500 [6.6]

8500 [2.5]

2

28100 [8.2]

9700 [2.8]

1

22600 [6.6]

8400 [2.5]

2

27500 [8.1]

9900 [2.9]

1

22600 [6.6]

8400 [2.5]

2

27500 [8.1]

9900 [2.9]

1

21900 [6.4]

8700 [2.5]

2

27400 [8.0]

10000 [2.9]

1

21900 [6.4]

8700 [2.5]

2

27400 [8.0]

10000 [2.9]

1

22100 [6.5]

8700 [2.5]

2

27700 [8.1]

9900 [2.9]

1

21300 [6.2]

8700 [2.5]

2

26400 [7.7]

10200 [3.0]

1

19500 [5.7]

9100 [2.7]

2

24600 [7.2]

10800 [3.2]

1

19700 [5.8]

9500 [2.8]

2

24100 [7.1]

11500 [3.4]

1

17100 [5.0]

2

27900 [8.2]

1 - dehumid

16800 [4.9]

5000 [1.5]

2 - dehumid

25600 [7.5]

12400 [3.6]

1

14400 [4.2]

5500 [1.6]

2

22000 [6.4]

13000 [3.8]

1

15100 [4.4]

5300 [1.6]

2

21750 [6.4]

13050 [3.8]

1

15250 [4.5]

5350 [1.6]

2

23450 [6.9]

12150 [3.6]

1

15250 [4.5]

5350 [1.6]

2

23450 [6.9]

12150 [3.6]

1

15100 [4.4]

5300 [1.6]

2

23450 [6.9]

12150 [3.6]

1

15250 [4.5]

5350 [1.6]

2

23600 [6.9]

12200 [3.6]

1

15250 [4.5]

5350 [1.6]

2

23450 [6.9]

12150 [3.6]

1

14300 [4.2]

5500 [1.6]

2

23450 [6.9]

12150 [3.6]

1

14450 [4.2]

5550 [1.6]

2

23250 [6.8]

12150 [3.6]

1

14400 [4.2]

5500 [1.6]

23300 [6.8]

12100 [3.5]

2
➀ Highest sales volume tested combination required by D.O.E. test procedures.

22

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

37600 [11.0]

17

13

37800 [11.1]

17

13

37400 [11.0]

16.5

13

37400 [11.0]
37400 [11.0]
37400 [11.0]

16.5
17
17

13
13
13

37600 [11.0]

17

13

36600 [10.7]

14.5

12

Sound
Rating
dB

975 [460]

69

1225 [578]

72

975 [460]

69

1225 [578]

72

1000 [472]

69

1200 [566]

72

1000 [472]

69

1200 [566]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1175 [554]

72

900 [425]

69

1200 [566]

72

925 [437]

69

1125 [531]

72

925 [437]

69

1225 [578]

72

950 [448]

69

1150 [543]

72

4700 [1.4]

825 [389]

69

11600 [3.4]

1175 [554]

73

35400 [10.4]
35600 [10.4]

39500 [11.6]

16
16.5

19.5

12.5
13

13.5

725 [342]
975 [460]

35000 [10.3]
34800 [10.2]
35600 [10.4]
35600 [10.4]
35600 [10.4]
35800 [10.5]
35600 [10.4]
35600 [10.4]
35400 [10.4]
35400 [10.4]

16.5
16.5
16
16
16
16.5
16
16
16
15.5

11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11

725 [342]

69

1000 [472]

73

800 [378]

69

1000 [472]

73

925 [437]

69

1200 [566]

73

925 [437]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

750 [354]

69

1025 [484]

73

775 [366]

69

1000 [472]

73

800 [378]

69

1025 [484]
73
[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Rev.
5/8/2012

Model Numbers
Stage
ID Coil

ID Air Mover

RCFL-H*3617

RGTM-06?MAE?

RCFL-H*3617+RXMD-C06

Coil Only
RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGGE-06?MCK?
RGGE-09?ZCM?
RGGE-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?

039JEC
RGJF-09?ZCM?
RCFL-H*3621
RGJF-10?ZCM?
RGLE-07?AMK?
RGLE-07?BRQ?
RGLE-10?BRM?
RGPE-05?BMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

15550 [4.6]

5450 [1.6]

2

23600 [6.9]

12200 [3.6]

1

14100 [4.1]

5400 [1.6]

2

23400 [6.9]

12200 [3.6]

1

15300 [4.5]

5100 [1.5]

2

23150 [6.8]

12050 [3.5]

1

13500 [4.0]

5900 [1.7]

2

21900 [6.4]

12900 [3.8]

1

15500 [4.5]

5100 [1.5]

2

23450 [6.9]

12150 [3.6]

1

13850 [4.1]

5750 [1.7]

2

23500 [6.9]

12100 [3.5]

1

15500 [4.5]

5300 [1.6]

2

23650 [6.9]

12150 [3.6]

1

13800 [4.0]

5800 [1.7]

2

24000 [7.0]

12000 [3.5]

1

13800 [4.0]

5800 [1.7]

2

23800 [7.0]

12000 [3.5]

1

15500 [4.5]

5300 [1.6]

2

23650 [6.9]

12150 [3.6]

1

15350 [4.5]

5250 [1.5]

2

23650 [6.9]

12150 [3.6]

1

15300 [4.5]

5300 [1.6]

2

23900 [7.0]

12300 [3.6]

1

15300 [4.5]

5300 [1.6]

2

23750 [7.0]

12250 [3.6]

1

15300 [4.5]

5300 [1.6]

2

23800 [7.0]

12200 [3.6]

1

15650 [4.6]

5350 [1.6]

2

23850 [7.0]

12350 [3.6]

1

15500 [4.5]

5300 [1.6]

2

23850 [7.0]

12350 [3.6]

1

15300 [4.5]

5300 [1.6]

2

23650 [6.9]

12150 [3.6]

1

15450 [4.5]

5350 [1.6]

2

23850 [7.0]

12350 [3.6]

1

15450 [4.5]

5350 [1.6]

2

23850 [7.0]

12350 [3.6]

1

14150 [4.1]

5450 [1.6]

2

23000 [6.7]

12000 [3.5]

1

14250 [4.2]

5450 [1.6]

2

23000 [6.7]

12000 [3.5]

1

14250 [4.2]

5450 [1.6]

2

22850 [6.7]

11950 [3.5]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

35800 [10.5]

15

11

35600 [10.4]

14

11

35200 [10.3]

16

11

34800 [10.2]
35600 [10.4]
35600 [10.4]

16.5
16.5
16.5

11.5
11.5
11.5

35800 [10.5]

16

11.5

36000 [10.5]

16

11.5

35800 [10.5]
35800 [10.5]
35800 [10.5]
36200 [10.6]
36000 [10.5]
36000 [10.5]
36200 [10.6]

16.5
16
16
16.5
16.5
16.5
17

11.5
11.5
11.5
12
12
11.5
12

36200 [10.6]

17.5

12.5

35800 [10.5]

16

11.5

36200 [10.6]
36200 [10.6]

17
17

12
12

35000 [10.3]

16

11.5

35000 [10.3]

16

11.5

34800 [10.2]

15.5

11

Sound
Rating
dB

1075 [507]

69

1225 [578]

73

800 [378]

69

1075 [507]

73

875 [413]

69

1200 [566]

73

550 [260]

69

1000 [472]

73

875 [413]

69

1200 [566]

73

600 [283]

69

1200 [566]

73

925 [437]

69

1200 [566]

73

575 [271]

69

1225 [578]

73

575 [271]

69

1200 [566]

73

925 [437]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

925 [437]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

750 [354]

69

1025 [484]

73

775 [366]

69

1000 [472]

73

800 [378]

69

1025 [484]

73

[ ] Designates Metric Conversions

23

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RCFL-H*3621
RGTM-06?MAE?
RGTM-07?RBG?
RGTM-09?ZAJ?
RCFL-H*3621+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?
RGFE-09?ZCM?
RGFE-10?ZCM?

039JEC
RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?
RCFL-H*3821

RGFG-10?ZCM?
RGGE-06?MCK?
RGGE-07?MCK?
RGGE-09?ZCM?
RGGE-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?

1

14050 [4.1]

5350 [1.6]

2

22900 [6.7]

11900 [3.5]

1

14600 [4.3]

5600 [1.6]

2

23550 [6.9]

12250 [3.6]

1

14450 [4.2]

5550 [1.6]

2

23400 [6.9]

12200 [3.6]

1

15800 [4.6]

5400 [1.6]

2

23450 [6.9]

12150 [3.6]

1

15650 [4.6]

5350 [1.6]

2

24050 [7.0]

12350 [3.6]

1

15600 [4.6]

5400 [1.6]

2

23900 [7.0]

12300 [3.6]

1

14100 [4.1]

5400 [1.6]

2

23400 [6.9]

12200 [3.6]

1

18000 [5.3]

7600 [2.2]

2

25400 [7.4]

11600 [3.4]

1

15400 [4.5]

8500 [2.5]

2

24400 [7.1]

12200 [3.6]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26400 [7.7]

11200 [3.3]

1

18000 [5.3]

7600 [2.2]

2

25400 [7.4]

11600 [3.4]

1

18700 [5.5]

7300 [2.1]

2

25800 [7.6]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

15200 [4.5]

8600 [2.5]

2

24600 [7.2]

12200 [3.6]

1

17200 [5.0]

8000 [2.3]

2

24400 [7.1]

12400 [3.6]

1

18100 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

17000 [5.0]

8000 [2.3]

2

24600 [7.2]

12200 [3.6]

1

18000 [5.3]

7600 [2.2]

2

25600 [7.5]

11600 [3.4]

1

18100 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

24

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

34800 [10.2]

16

11.5

35800 [10.5]

15.5

11.5

35600 [10.4]

16

11.5

35600 [10.4]
36400 [10.7]
36200 [10.6]

15.5
16.5
16.5

11
12
12

35600 [10.4]

14

11

37000 [10.8]

16

12.5

36600 [10.7]
37400 [11.0]
37600 [11.0]
37000 [10.8]
37200 [10.9]
37400 [11.0]
37400 [11.0]

17
17
17
16
15.5
17
17

13
13
13
12.5
12
13
13

36800 [10.8]

16.5

13

36800 [10.8]

16.5

13

37800 [11.1]
37400 [11.0]

17
17

13
13

36800 [10.8]

17

13

37200 [10.9]

16

12.5

37800 [11.1]

17

13

Sound
Rating
dB

700 [330]

69

975 [460]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

1075 [507]

69

1225 [578]

73

950 [448]

69

1275 [602]

73

975 [460]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

875 [413]

69

1200 [566]

73

500 [236]

69

1025 [484]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

1000 [472]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

475 [224]

69

1025 [484]

73

750 [354]

69

1025 [484]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

725 [342]

69

1025 [484]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGJF-10?ZCM?
RGLE-07?AMK?
RGLE-07?BRQ?
RGLE-10?BRM?
RGPE-05?BMK?
RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?

039JEC

RCFL-H*3821
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGTM-06?MAE?
RGTM-07?RBG?
RGTM-09?ZAJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

17200 [5.0]

8000 [2.3]

2

24600 [7.2]

12200 [3.6]

1

18600 [5.4]

7500 [2.2]

2

26600 [7.8]

11200 [3.3]

1

18200 [5.3]

7600 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18200 [5.3]

7600 [2.2]

2

25600 [7.5]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18400 [5.4]

7600 [2.2]

2

26600 [7.8]

11400 [3.3]

1

18400 [5.4]

7600 [2.2]

2

26600 [7.8]

11400 [3.3]

1

17100 [5.0]

8000 [2.3]

2

24400 [7.1]

12200 [3.6]

1

18100 [5.3]

7600 [2.2]

2

25400 [7.4]

11600 [3.4]

1

17600 [5.2]

7800 [2.3]

2

24200 [7.1]

12200 [3.6]

1

17600 [5.2]

7800 [2.3]

2

25200 [7.4]

11600 [3.4]

1

18600 [5.4]

7400 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18200 [5.3]

7600 [2.2]

2

24400 [7.1]

12200 [3.6]

1

18700 [5.5]

7400 [2.2]

2

26800 [7.9]

11200 [3.3]

1

18900 [5.5]

7400 [2.2]

2

26400 [7.7]

11400 [3.3]

1

19000 [5.6]

7300 [2.1]

2

25800 [7.6]

11600 [3.4]

1

19000 [5.6]

7300 [2.1]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

37400 [11.0]

17

13

36800 [10.8]

17

13

37800 [11.1]

17

13

37600 [11.0]
37200 [10.9]
37600 [11.0]

17.5
16.5
16.5

13
12.5
13

38000 [11.1]

17

13

38000 [11.1]

17

13

36600 [10.7]
37000 [10.8]
36400 [10.7]
36800 [10.8]
37600 [11.0]
37400 [11.0]
36600 [10.7]

16.5
16
16.5
16
16.5
16.5
16.5

12.5
12
12.5
12
12.5
13
13

38000 [11.1]

17

13

37800 [11.1]

17

13

37400 [11.0]
37400 [11.0]

16.5
16.5

13
13

37600 [11.0]

17

13

37600 [11.0]

17

13

37600 [11.0]

17

13

Sound
Rating
dB

875 [413]

69

1200 [566]

73

750 [354]

69

1025 [484]

73

925 [437]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

750 [354]

69

1025 [484]

73

900 [425]

69

1175 [554]

73

800 [378]

69

1025 [484]

73

850 [401]

69

1200 [566]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

900 [425]

69

1025 [484]

73

950 [448]

69

1275 [602]

73

975 [460]

69

1225 [578]

73

1000 [472]

69

1200 [566]

73

1000 [472]

69

1200 [566]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1200 [566]

73

[ ] Designates Metric Conversions

25

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

RCFL-H*3821+RXMD-C06

ID Air Mover

Coil Only
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGGE-09?ZCM?
RGGE-10?ZCM?
RGGE-12?RCM?
RGJF-09?ZCM?

039JEC
RCFL-H*3824

RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-07?BRQ?
RGLE-10?BRM?
RGLE-12?ARM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?

1

17100 [5.0]

7800 [2.3]

2

25400 [7.4]

11600 [3.4]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18200 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18200 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

18200 [5.3]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

18100 [5.3]

7600 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

1

19500 [5.7]

7100 [2.1]

2

26800 [7.9]

11200 [3.3]

1

18600 [5.4]

7500 [2.2]

2

26600 [7.8]

11200 [3.3]

1

18200 [5.3]

7600 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18600 [5.4]

7500 [2.2]

2

26600 [7.8]

11400 [3.3]

1

18400 [5.4]

7600 [2.2]

2

26600 [7.8]

11200 [3.3]

1

18400 [5.4]

7600 [2.2]

2

26600 [7.8]

11200 [3.3]

1

18200 [5.3]

7600 [2.2]

2

26200 [7.7]

11400 [3.3]

1

17500 [5.1]

7800 [2.3]

2

25200 [7.4]

11600 [3.4]

1

18600 [5.4]

7400 [2.2]

2

26200 [7.7]

11400 [3.3]

1

18100 [5.3]

7600 [2.2]

2

25800 [7.6]

11600 [3.4]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

26

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

37000 [10.8]

15

12

37400 [11.0]

17

13

37600 [11.0]

17

13

37800 [11.1]
37400 [11.0]
37400 [11.0]

17
17
16.5

13
13
13

37800 [11.1]

17

13

37800 [11.1]

17

13

37400 [11.0]
37600 [11.0]
37800 [11.1]
37400 [11.0]
38000 [11.1]
37800 [11.1]
37600 [11.0]

17
17
17
17
17
17
17.5

13
13
13
13
13
13
13

38000 [11.1]

17.5

13

37800 [11.1]

17

13

37800 [11.1]
37600 [11.0]

17
17

13
13

36800 [10.8]

16

12

37600 [11.0]

16.5

12.5

37400 [11.0]

16.5

13

Sound
Rating
dB

825 [389]

69

1175 [554]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

1050 [495]

69

1250 [590]

73

925 [437]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

925 [437]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

850 [401]

69

1200 [566]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGRM-12?RAJ?
RGTM-07?RBG?
RGTM-09?ZAJ?
RGTM-10?RBJ?
RCFL-H*3824

ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05

RCFL-H*3824+RXMD-C06

Coil Only
RGFE-09?ZCM?

039JEC
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RCFN-H*3624
RGGE-09?ZCM?
RGGE-10?ZCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-07?BRQ?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

18500 [5.4]

7500 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18700 [5.5]

7400 [2.2]

2

26800 [7.9]

11200 [3.3]

1

18900 [5.5]

7400 [2.2]

2

26400 [7.7]

11400 [3.3]

1

18900 [5.5]

7400 [2.2]

2

26600 [7.8]

11200 [3.3]

1

19000 [5.6]

7300 [2.1]

2

25800 [7.6]

11600 [3.4]

1

19000 [5.6]

7300 [2.1]

2

25800 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

18300 [5.4]

7600 [2.2]

2

26000 [7.6]

11600 [3.4]

1

17100 [5.0]

7800 [2.3]

2

25400 [7.4]

11600 [3.4]

1

17100 [5.0]

4700 [1.4]

2

27750 [8.1]

11250 [3.3]

1

17250 [5.1]

4750 [1.4]

2

27850 [8.2]

11650 [3.4]

1

17100 [5.0]

4700 [1.4]

2

28000 [8.2]

11500 [3.4]

1

17300 [5.1]

4500 [1.3]

2

27550 [8.1]

11450 [3.4]

1

15500 [4.5]

5100 [1.5]

2

27500 [8.1]

11500 [3.4]

1

17400 [5.1]

4600 [1.3]

2

28250 [8.3]

11250 [3.3]

1

17300 [5.1]

4500 [1.3]

2

28200 [8.3]

11300 [3.3]

1

15400 [4.5]

5300 [1.6]

2

27600 [8.1]

11400 [3.3]

1

17100 [5.0]

4700 [1.4]

2

28050 [8.2]

11450 [3.4]

1

17100 [5.0]

4700 [1.4]

2

27750 [8.1]

11250 [3.3]

1

17100 [5.0]

4700 [1.4]

2

27850 [8.2]

11650 [3.4]

1

17250 [5.1]

4750 [1.4]

2

28000 [8.2]

11500 [3.4]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

37800 [11.1]

17

13

38000 [11.1]

17

13

37800 [11.1]

17

13

37800 [11.1]
37400 [11.0]
37400 [11.0]

17
16.5
16.5

13
13
13

37600 [11.0]

17

13

37600 [11.0]

17

13

37600 [11.0]
37000 [10.8]
39000 [11.4]
39500 [11.6]
39500 [11.6]
39000 [11.4]
39000 [11.4]

17
15
18
18
18.5
18
18

13
12
13
13
13
13
13

39500 [11.6]

18.5

13

39500 [11.6]

18

13

39000 [11.4]
39500 [11.6]

18
18

13
13

39000 [11.4]

18

13

39500 [11.6]

18.5

13.5

39500 [11.6]

18.5

13.5

Sound
Rating
dB

925 [437]

69

1225 [578]

73

950 [448]

69

1275 [602]

73

975 [460]

69

1225 [578]

73

975 [460]

69

1225 [578]

73

1000 [472]

69

1200 [566]

73

1000 [472]

69

1200 [566]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1200 [566]

73

825 [389]

69

1175 [554]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

600 [283]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

575 [271]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

925 [437]

69

1225 [578]

73

[ ] Designates Metric Conversions

27

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGLE-10?BRM?
RGLE-12?ARM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RCFN-H*3624

RGRM-12?RAJ?
RGTM-07?RBG?
RGTM-09?ZAJ?

039JEC
RGTM-10?RBJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04
ROLA-115E05
RCFN-H*3624+RXMD-C06

Coil Only
RGFE-06?MCK?
RGFE-07?MCK?

RCQD-3621
RGFE-09?ZCM?
RGFE-10?ZCM?

1

17300 [5.1]

4700 [1.4]

2

27850 [8.2]

11650 [3.4]

1

17400 [5.1]

4800 [1.4]

2

28150 [8.2]

11350 [3.3]

1

17250 [5.1]

4750 [1.4]

2

28000 [8.2]

11500 [3.4]

1

17250 [5.1]

4750 [1.4]

2

28000 [8.2]

11500 [3.4]

1

17100 [5.0]

4700 [1.4]

2

27850 [8.2]

11650 [3.4]

1

16800 [4.9]

4600 [1.3]

2

27300 [8.0]

11200 [3.3]

1

17250 [5.1]

4750 [1.4]

2

27700 [8.1]

11300 [3.3]

1

17100 [5.0]

4700 [1.4]

2

27750 [8.1]

11250 [3.3]

1

17250 [5.1]

4750 [1.4]

2

27850 [8.2]

11650 [3.4]

1

17250 [5.1]

4750 [1.4]

2

28150 [8.2]

11350 [3.3]

1

17400 [5.1]

4800 [1.4]

2

27850 [8.2]

11650 [3.4]

1

17400 [5.1]

4800 [1.4]

2

28000 [8.2]

11500 [3.4]

1

17400 [5.1]

4800 [1.4]

2

27550 [8.1]

11450 [3.4]

1

17400 [5.1]

4800 [1.4]

2

27550 [8.1]

11450 [3.4]

1

17250 [5.1]

4750 [1.4]

2

27700 [8.1]

11300 [3.3]

1

17250 [5.1]

4750 [1.4]

2

27700 [8.1]

11300 [3.3]

1

17250 [5.1]

4750 [1.4]

2

27900 [8.2]

11500 [3.4]

1

16800 [4.9]

4400 [1.3]

2

27300 [8.0]

11300 [3.3]

1

16850 [4.9]

4550 [1.3]

2

26550 [7.8]

11050 [3.2]

1

16850 [4.9]

4550 [1.3]

2

26700 [7.8]

11100 [3.3]

1

17000 [5.0]

4600 [1.3]

2

26800 [7.9]

11200 [3.3]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

11050 [3.2]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

28

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

39500 [11.6]

18.5

13.5

39500 [11.6]

19

13.5

39500 [11.6]

18.5

13.5

39500 [11.6]
39500 [11.6]
38500 [11.3]

18.5
18.5
17

13.5
13.5
12

39000 [11.4]

17.5

13

39000 [11.4]

18

13

39500 [11.6]
39500 [11.6]
39500 [11.6]
39500 [11.6]
39000 [11.4]
39000 [11.4]
39000 [11.4]

18.5
18
18
18.5
17
17
17.5

13
13
13
13.5
13
13
13

39000 [11.4]

17.5

13

39500 [11.6]

17.5

13.5

38500 [11.3]
37600 [11.0]

15.5
16.5

12
12

37800 [11.1]

16.5

12

38000 [11.1]

17.5

12.5

38000 [11.1]

17.5

12.5

Sound
Rating
dB

875 [413]

69

1200 [566]

73

925 [437]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

850 [401]

69

1200 [566]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

925 [437]

69

1225 [578]

73

950 [448]

69

1275 [602]

73

975 [460]

69

1225 [578]

73

975 [460]

69

1225 [578]

73

1000 [472]

69

1200 [566]

73

1000 [472]

69

1200 [566]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1200 [566]

73

875 [413]

69

1175 [554]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGFG-06?MCK?
RGFG-07?MCK?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGJF-06?MCK?
RGJF-07?MCK?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGPE-05?BMK?
RGPE-07?AMK?
RGPE-07?BRQ?

039JEC

RCQD-3621
RGPE-10?BRM?
RGRM-04?MAE?
RGRM-06?MAE?
RGRM-07?MAE?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

15200 [4.5]

5200 [1.5]

2

26550 [7.8]

11050 [3.2]

1

15250 [4.5]

5150 [1.5]

2

27000 [7.9]

10800 [3.2]

1

17200 [5.0]

4400 [1.3]

2

26850 [7.9]

11150 [3.3]

1

15250 [4.5]

5150 [1.5]

2

26850 [7.9]

11150 [3.3]

1

17200 [5.0]

4600 [1.3]

2

26650 [7.8]

11150 [3.3]

1

16850 [4.9]

4550 [1.3]

2

26700 [7.8]

11100 [3.3]

1

17000 [5.0]

4600 [1.3]

2

27100 [7.9]

11300 [3.3]

1

17050 [5.0]

4550 [1.3]

2

26800 [7.9]

11200 [3.3]

1

17000 [5.0]

4600 [1.3]

2

26700 [7.8]

11100 [3.3]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

11050 [3.2]

1

17200 [5.0]

4600 [1.3]

2

27300 [8.0]

11200 [3.3]

1

17200 [5.0]

4600 [1.3]

2

27250 [8.0]

11250 [3.3]

1

16150 [4.7]

4650 [1.4]

2

26250 [7.7]

10550 [3.1]

1

16450 [4.8]

4750 [1.4]

2

26700 [7.8]

10700 [3.1]

1

16350 [4.8]

4650 [1.4]

2

26300 [7.7]

10500 [3.1]

1

16300 [4.8]

4700 [1.4]

2

26550 [7.8]

10650 [3.1]

1

16800 [4.9]

4800 [1.4]

2

27000 [7.9]

10800 [3.2]

1

16450 [4.8]

4750 [1.4]

2

26850 [7.9]

10750 [3.1]

1

17350 [5.1]

4650 [1.4]

2

26850 [7.9]

10750 [3.1]

1

17350 [5.1]

4650 [1.4]

2

26850 [7.9]

10750 [3.1]

1

17200 [5.0]

4750 [1.4]

2

26950 [7.9]

10650 [3.1]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

10650 [3.1]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

37600 [11.0]

17

12

37800 [11.1]

17

12

38000 [11.1]

17.5

12.5

38000 [11.1]
37800 [11.1]
37800 [11.1]

17.5
17
17

12.5
12.5
12

38500 [11.3]

17.5

13

38000 [11.1]

17.5

12.5

37800 [11.1]
38000 [11.1]
38500 [11.3]
38500 [11.3]
36800 [10.8]
37400 [11.0]
36800 [10.8]

17
17.5
18
18
16.5
16
16.5

12.5
12.5
13
13
12
11.5
12

37200 [10.9]

16

11.5

37800 [11.1]

16.5

12

37600 [11.0]
37600 [11.0]

16.5
16

12.5
12.5

37600 [11.0]

16

12.5

37600 [11.0]

16.5

13

37600 [11.0]

16.5

13

Sound
Rating
dB

575 [271]

69

1200 [566]

73

600 [283]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

600 [283]

69

1200 [566]

73

925 [437]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

750 [354]

69

1025 [484]

73

900 [425]

69

1175 [554]

73

800 [378]

69

1025 [484]

73

850 [401]

69

1200 [566]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

1000 [472]

69

1200 [566]

73

1000 [472]

69

1200 [566]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1175 [554]

73

[ ] Designates Metric Conversions

29

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

RCQD-3621+RXMD-C06

ID Air Mover

Coil Only
RBHM-24J*
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?

039JEC
RCQD-3624

RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
ROCA-070E03
ROCA-070E04
ROLA-070E03
ROLA-070E04

1

15850 [4.6]

4550 [1.3]

2

26700 [7.8]

10700 [3.1]

1

16800 [4.9]

4800 [1.4]

2

27450 [8.0]

11050 [3.2]

1

17000 [5.0]

4600 [1.3]

2

26800 [7.9]

11200 [3.3]

1

17200 [5.0]

4600 [1.3]

2

27150 [8.0]

11350 [3.3]

1

17000 [5.0]

4600 [1.3]

2

27100 [7.9]

11400 [3.3]

1

17200 [5.0]

4400 [1.3]

2

26800 [7.9]

11200 [3.3]

1

15300 [4.5]

5100 [1.5]

2

26800 [7.9]

11200 [3.3]

1

17150 [5.0]

4450 [1.3]

2

27550 [8.1]

10950 [3.2]

1

17000 [5.0]

4600 [1.3]

2

27100 [7.9]

11400 [3.3]

1

17050 [5.0]

4550 [1.3]

2

27000 [7.9]

11000 [3.2]

1

17200 [5.0]

4600 [1.3]

2

27150 [8.0]

11350 [3.3]

1

17200 [5.0]

4600 [1.3]

2

27250 [8.0]

11250 [3.3]

1

17200 [5.0]

4600 [1.3]

2

27250 [8.0]

11250 [3.3]

1

17200 [5.0]

4600 [1.3]

2

27100 [7.9]

11400 [3.3]

1

16300 [4.8]

4700 [1.4]

2

26700 [7.8]

10700 [3.1]

1

16800 [4.9]

4800 [1.4]

2

27000 [7.9]

10800 [3.2]

1

16450 [4.8]

4750 [1.4]

2

26850 [7.9]

10750 [3.1]

1

16800 [4.9]

4800 [1.4]

2

27150 [8.0]

10850 [3.2]

1

17350 [5.1]

4650 [1.4]

2

26800 [7.9]

10800 [3.2]

1

17350 [5.1]

4650 [1.4]

2

26800 [7.9]

10800 [3.2]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

10650 [3.1]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

10650 [3.1]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

30

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

37400 [11.0]

14.5

11.5

38500 [11.3]

17.5

13

38000 [11.1]

17.5

12.5

38500 [11.3]
38500 [11.3]
38000 [11.1]

17.5
18
17.5

12.5
13
12.5

38000 [11.1]

17.5

12.5

38500 [11.3]

18

13

38500 [11.3]
38000 [11.1]
38500 [11.3]
38500 [11.3]
38500 [11.3]
38500 [11.3]
37400 [11.0]

17.5
17.5
18
18
18
18
16

13
13
13
13
13
13
11.5

37800 [11.1]

16.5

12.5

37600 [11.0]

16.5

12.5

38000 [11.1]
37600 [11.0]

17
16.5

12.5
12.5

37600 [11.0]

16.5

12.5

37600 [11.0]

17

13

37600 [11.0]

17

13

Sound
Rating
dB

800 [378]

69

1200 [566]

73

900 [425]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

600 [283]

69

1200 [566]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

875 [413]

69

1200 [566]

73

900 [425]

69

1225 [578]

73

900 [425]

69

1225 [578]

73

875 [413]

69

1200 [566]

73

850 [401]

69

1200 [566]

73

950 [448]

69

1225 [578]

73

875 [413]

69

1150 [543]

73

925 [437]

69

1225 [578]

73

1000 [472]

69

1200 [566]

73

1000 [472]

69

1200 [566]

73

900 [425]

69

1175 [554]

73

900 [425]

69

1175 [554]

73

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

039JEC

RCQD-3624
RCQD-3624+RXMD-C06
RCSL-H*3621

RCSN-H*4824 ➀

ID Air Mover

ROLA-115E05
Coil Only
RHPL-HM3621

RHPN-HM4824

RGFE-07?MCK?
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFG-07?MCK?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGGE-09?ZCM?
048JEC

RGGE-10?ZCM?
RCFL-H*4821

RGJF-09?ZCM?
RGJF-10?ZCM?
RGLE-07?BRQ?
RGLE-10?BRM?
RGPE-07?AMK?
RGPE-07?BRQ?
RGPE-10?BRM?
RGRM-07?MAE?
RGRM-07?YBG?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

17200 [5.0]

4600 [1.3]

2

26950 [7.9]

10650 [3.1]

1

16200 [4.7]

4600 [1.3]

2

26200 [7.7]

11400 [3.3]

1

14750 [4.3]

5650 [1.7]

2

23800 [7.0]

12400 [3.6]

1

20800 [6.1]

5800 [1.7]

2

35800 [10.5]

12700 [3.7]

1 - dehumid

19200 [5.6]

6800 [2.0]

2 - dehumid

32800 [9.6]

14200 [4.2]

1

17100 [5.0]

6900 [2.0]

2

28700 [8.4]

13800 [4.0]

1

17800 [5.2]

7200 [2.1]

2

29500 [8.6]

14100 [4.1]

1

17800 [5.2]

7200 [2.1]

2

29550 [8.7]

13950 [4.1]

1

17100 [5.0]

7300 [2.1]

2

26250 [7.7]

16250 [4.8]

1

16200 [4.7]

7800 [2.3]

2

29350 [8.6]

14150 [4.1]

1

15850 [4.6]

7950 [2.3]

2

27500 [8.1]

15500 [4.5]

1

17950 [5.3]

7250 [2.1]

2

29650 [8.7]

13850 [4.1]

1

17800 [5.2]

7200 [2.1]

2

29500 [8.6]

14000 [4.1]

1

16300 [4.8]

7900 [2.3]

2

29200 [8.6]

14800 [4.3]

1

16300 [4.8]

7900 [2.3]

2

29200 [8.6]

14300 [4.2]

1

17950 [5.3]

7250 [2.1]

2

29800 [8.7]

14200 [4.2]

1

17950 [5.3]

7250 [2.1]

2

30100 [8.8]

14300 [4.2]

1

17250 [5.1]

6950 [2.0]

2

29000 [8.5]

13500 [4.0]

1

17950 [5.3]

7250 [2.1]

2

29750 [8.7]

14250 [4.2]

1

18150 [5.3]

7250 [2.1]

2

29950 [8.8]

14050 [4.1]

1

17150 [5.0]

7050 [2.1]

2

28600 [8.4]

14400 [4.2]

1

17450 [5.1]

7150 [2.1]

28900 [8.5]

14600 [4.3]

2
➀ Highest sales volume tested combination required by D.O.E. test procedures.

37600 [11.0]

17

13

37600 [11.0]

14.5

11.5

36200 [10.6]

17

12

48500 [14.2]

18

13

Sound
Rating
dB

900 [425]

69

1200 [566]

73

825 [389]

69

1175 [554]

73

925 [437]

69

1225 [578]

73

1000 [472]

73

1600 [755]

74

825 [389]
1300 [613]

42500 [12.5]
43500 [12.7]
43500 [12.7]
42500 [12.5]
43500 [12.7]

15.5
15
15
15.5
16

11
10.5
10.5
11
10.5

43000 [12.6]

16

11

43500 [12.7]

15.5

11

43500 [12.7]
44000 [12.9]
43500 [12.7]
44000 [12.9]
44500 [13.0]
42500 [12.5]
44000 [12.9]
44000 [12.9]
43000 [12.6]
43500 [12.7]

15
16
16
16
16
16.5
16
16
15
14.5

10.5
11
10.5
11
11.5
11.5
11
11.5
11
10.5

875 [413]

73

1225 [578]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

925 [437]

73

1225 [578]

74

775 [366]

73

1600 [755]

74

725 [342]

73

1400 [661]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

775 [366]

73

1600 [755]

74

775 [366]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

900 [425]

73

1225 [578]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

950 [448]

73

1225 [578]

74

1050 [495]

73

1400 [661]
74
[ ] Designates Metric Conversions

31

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGRM-09?ZAJ?
RCFL-H*4821

RGRM-10?ZAJ?
RGTM-09?ZAJ?

RCFL-H*4821+RXMD-C06

Coil Only
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGGE-09?ZCM?

048JEC
RGGE-10?ZCM?
RGGE-12?RCM?
RCFL-H*4824
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-10?BRM?
RGLE-12?ARM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-07?YBG?

1

17450 [5.1]

7150 [2.1]

2

29200 [8.6]

14800 [4.3]

1

17600 [5.2]

7200 [2.1]

2

29400 [8.6]

14600 [4.3]

1

17950 [5.3]

7250 [2.1]

2

29700 [8.7]

13800 [4.0]

1

19200 [5.6]

6200 [1.8]

2

29600 [8.7]

14400 [4.2]

1

18300 [5.4]

6900 [2.0]

2

30050 [8.8]

13950 [4.1]

1

18250 [5.3]

6950 [2.0]

2

30100 [8.8]

13900 [4.1]

1

18400 [5.4]

7000 [2.1]

2

30200 [8.8]

14300 [4.2]

1

16650 [4.9]

7550 [2.2]

2

29800 [8.7]

14200 [4.2]

1

16900 [5.0]

7500 [2.2]

2

30800 [9.0]

13700 [4.0]

1

16600 [4.9]

7600 [2.2]

2

30450 [8.9]

14050 [4.1]

1

18450 [5.4]

6950 [2.0]

2

30200 [8.8]

14300 [4.2]

1

18300 [5.4]

6900 [2.0]

2

30050 [8.8]

13950 [4.1]

1

18400 [5.4]

7000 [2.1]

2

30500 [8.9]

14000 [4.1]

1

16700 [4.9]

7600 [2.2]

2

29800 [8.7]

14700 [4.3]

1

16100 [4.7]

7900 [2.3]

2

28000 [8.2]

16000 [4.7]

1

16800 [4.9]

7600 [2.2]

2

30200 [8.8]

14800 [4.3]

1

18400 [5.4]

7000 [2.1]

2

30650 [9.0]

14350 [4.2]

1

18600 [5.4]

7000 [2.1]

2

30450 [8.9]

14050 [4.1]

1

18400 [5.4]

7000 [2.1]

2

30300 [8.9]

14200 [4.2]

1

18600 [5.4]

7000 [2.1]

2

30500 [8.9]

14000 [4.1]

1

18400 [5.4]

7000 [2.1]

2

30450 [8.9]

14050 [4.1]

1

17950 [5.3]

6850 [2.0]

2

29300 [8.6]

14200 [4.2]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

32

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

44000 [12.9]
44000 [12.9]
43500 [12.7]
44000 [12.9]
44000 [12.9]
44000 [12.9]

16
15.5
15.5
14
15.5
15

12
11.5
11
11
11
10.5

44500 [13.0]

15.5

11

44000 [12.9]

16

11

44500 [13.0]
44500 [13.0]
44500 [13.0]
44000 [12.9]
44500 [13.0]
44500 [13.0]
44000 [12.9]

16
16
15.5
15.5
16
16.5
16.5

10.5
11
11
11
11.5
11
11.5

45000 [13.2]

16.5

11.5

45000 [13.2]

16.5

11.5

44500 [13.0]
44500 [13.0]

16.5
16

11.5
11.5

44500 [13.0]

16

11.5

44500 [13.0]

16.5

11.5

43500 [12.7]

15

10.5

Sound
Rating
dB

950 [448]

73

1225 [578]

74

1025 [484]

73

1425 [672]

74

1250 [590]

73

1600 [755]

74

1100 [519]

73

1475 [696]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

775 [366]

73

1600 [755]

74

800 [378]

73

1650 [779]

74

775 [366]

73

1625 [767]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1575 [743]

74

775 [366]

73

1600 [755]

74

675 [319]

73

1400 [661]

74

775 [366]

73

1575 [743]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

1200 [566]

73

1625 [767]

74

1050 [495]

73

1400 [661]

74

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGRM-09?ZAJ?
RGRM-10?ZAJ?
RCFL-H*4824
RGRM-12?RAJ?
RGTM-09?ZAJ?
RCFL-H*4824+RXMD-C06

Coil Only
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?

048JEC
RGGE-09?ZCM?
RGGE-10?ZCM?
RCFN-H*4824

RGGE-12?RCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGLE-10?BRM?
RGLE-12?ARM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

17950 [5.3]

6850 [2.0]

2

29550 [8.7]

14450 [4.2]

1

18100 [5.3]

6900 [2.0]

2

29800 [8.7]

14200 [4.2]

1

17950 [5.3]

6850 [2.0]

2

29700 [8.7]

14300 [4.2]

1

18400 [5.4]

7000 [2.1]

2

30250 [8.9]

14250 [4.2]

1

19200 [5.6]

6200 [1.8]

2

29600 [8.7]

14400 [4.2]

1

21050 [6.2]

5950 [1.7]

2

35000 [10.3]

12500 [3.7]

1

21250 [6.2]

5950 [1.7]

2

34800 [10.2]

12200 [3.6]

1

21200 [6.2]

6000 [1.8]

2

35150 [10.3]

12350 [3.6]

1

19000 [5.6]

6600 [1.9]

2

35150 [10.3]

12350 [3.6]

1

19200 [5.6]

6400 [1.9]

2

35450 [10.4]

12050 [3.5]

1

19100 [5.6]

6500 [1.9]

2

35050 [10.3]

12450 [3.6]

1

21200 [6.2]

6000 [1.8]

2

35150 [10.3]

12350 [3.6]

1

21050 [6.2]

5950 [1.7]

2

34950 [10.2]

12550 [3.7]

1

21200 [6.2]

6000 [1.8]

2

35250 [10.3]

12250 [3.6]

1

21200 [6.2]

6000 [1.8]

2

35150 [10.3]

12350 [3.6]

1

21050 [6.2]

5950 [1.7]

2

34950 [10.2]

12550 [3.7]

1

21200 [6.2]

6000 [1.8]

2

35250 [10.3]

12250 [3.6]

1

21400 [6.3]

6000 [1.8]

2

35400 [10.4]

12600 [3.7]

1

21350 [6.3]

6050 [1.8]

2

35400 [10.4]

12600 [3.7]

1

20950 [6.1]

5850 [1.7]

2

34800 [10.2]

12200 [3.6]

1

21400 [6.3]

6000 [1.8]

2

35250 [10.3]

12250 [3.6]

1

21400 [6.3]

6000 [1.8]

2

35400 [10.4]

12600 [3.7]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

44000 [12.9]
44000 [12.9]
44000 [12.9]
44500 [13.0]
44000 [12.9]
47500 [13.9]

16
16
16.5
15.5
14
16.5

12
11.5
12
11
11
11.5

47000 [13.8]

16.5

11.5

47500 [13.9]

17

12

47500 [13.9]
47500 [13.9]
47500 [13.9]
47500 [13.9]
47500 [13.9]
47500 [13.9]
47500 [13.9]

17.5
17.5
17.5
17
16.5
17.5
17

11.5
11.5
12
12
11.5
12
12

47500 [13.9]

16.5

11.5

47500 [13.9]

17.5

12

48000 [14.1]
48000 [14.1]

17.5
17.5

12.5
12.5

47000 [13.8]

17.5

12.5

47500 [13.9]

17

12

48000 [14.1]

17.5

12.5

Sound
Rating
dB

950 [448]

73

1225 [578]

74

1025 [484]

73

1425 [672]

74

925 [437]

73

1225 [578]

74

1250 [590]

73

1600 [755]

74

1075 [507]

73

1425 [672]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

775 [366]

73

1600 [755]

74

800 [378]

73

1650 [779]

74

775 [366]

73

1625 [767]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1575 [743]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1575 [743]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1050 [495]

73

1400 [661]

74

1225 [578]

73

1625 [767]

74

1200 [566]

73

1625 [767]

74

[ ] Designates Metric Conversions

33

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
RGTM-07?RBG?
RCFN-H*4824
RGTM-09?ZAJ?
RGTM-10?RBJ?
ROCA-070E04
ROLA-070E04
ROLA-115E05
RCFN-H*4824+RXMD-C06

Coil Only

048JEC
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGJF-09?ZCM?
RCQD-4821

RGJF-10?ZCM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?

1

20400 [6.0]

5800 [1.7]

2

33950 [9.9]

12050 [3.5]

1

20750 [6.1]

5850 [1.7]

2

34550 [10.1]

12450 [3.6]

1

20600 [6.0]

5800 [1.7]

2

34550 [10.1]

12450 [3.6]

1

20900 [6.1]

5900 [1.7]

2

34650 [10.2]

12350 [3.6]

1

21550 [6.3]

6050 [1.8]

2

35250 [10.3]

12250 [3.6]

1

21400 [6.3]

6000 [1.8]

2

34950 [10.2]

12550 [3.7]

1

21350 [6.3]

6050 [1.8]

2

35400 [10.4]

12600 [3.7]

1

21050 [6.2]

5950 [1.7]

2

34550 [10.1]

11950 [3.5]

1

21050 [6.2]

5950 [1.7]

2

34950 [10.2]

12550 [3.7]

1

21200 [6.2]

6000 [1.8]

2

35300 [10.3]

12200 [3.6]

1

21400 [6.3]

5100 [1.5]

2

34800 [10.2]

12700 [3.7]

1

19850 [5.8]

5750 [1.7]

2

33400 [9.8]

12100 [3.5]

1

20000 [5.9]

5800 [1.7]

2

33400 [9.8]

12100 [3.5]

1

18450 [5.4]

6550 [1.9]

2

33300 [9.8]

12200 [3.6]

1

20400 [6.0]

5600 [1.6]

2

29950 [8.8]

14550 [4.3]

1

20200 [5.9]

5800 [1.7]

2

33550 [9.8]

11950 [3.5]

1

20050 [5.9]

5750 [1.7]

2

33550 [9.8]

11950 [3.5]

1

20150 [5.9]

5850 [1.7]

2

33850 [9.9]

12150 [3.6]

1

20150 [5.9]

5850 [1.7]

2

33850 [9.9]

12150 [3.6]

1

19300 [5.7]

5500 [1.6]

2

32500 [9.5]

12000 [3.5]

1

19450 [5.7]

5550 [1.6]

2

33100 [9.7]

11900 [3.5]

1

19450 [5.7]

5550 [1.6]

2

33050 [9.7]

11950 [3.5]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

34

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

46000 [13.5]
47000 [13.8]
47000 [13.8]
47000 [13.8]
47500 [13.9]
47500 [13.9]

16
17
17
17.5
16.5
16.5

11
12
12
12
11.5
11.5

48000 [14.1]

16.5

12

46500 [13.6]

15.5

12

47500 [13.9]
47500 [13.9]
47500 [13.9]
45500 [13.3]
45500 [13.3]
45500 [13.3]
44500 [13.0]

16
16.5
15.5
16
15.5
16.5
16.5

11.5
12
12
11
11
11
12

45500 [13.3]

16

11.5

45500 [13.3]

16

11.5

46000 [13.5]
46000 [13.5]

16.5
16.5

12
12

44500 [13.0]

15.5

10.5

45000 [13.2]

16.5

11.5

45000 [13.2]

16.5

11.5

Sound
Rating
dB

1050 [495]

73

1400 [661]

74

1075 [507]

73

1400 [661]

74

1025 [484]

73

1425 [672]

74

1075 [507]

73

1425 [672]

74

1325 [625]

73

1675 [790]

74

1250 [590]

73

1600 [755]

74

1275 [602]

73

1675 [790]

74

1200 [566]

73

1400 [661]

74

1175 [554]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

775 [366]

73

1600 [755]

74

1050 [495]

73

1275 [602]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

1050 [495]

73

1400 [661]

74

1075 [507]

73

1400 [661]

74

1025 [484]

73

1425 [672]

74

[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

ROCA-070E04
RCQD-4821
ROLA-070E04
RCQD-4821+RXMD-C06

Coil Only
RBHM-25J*
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGJF-09?ZCM?

048JEC
RGJF-10?ZCM?
RCQD-4824

RGJF-12?RCM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-07?YBG?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
ROCA-070E04
ROLA-070E04

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

19850 [5.8]

5750 [1.7]

2

33350 [9.8]

12650 [3.7]

1

20000 [5.9]

5800 [1.7]

2

33750 [9.9]

12250 [3.6]

1

21400 [6.3]

4500 [1.3]

2

33600 [9.8]

12400 [3.6]

1

20500 [6.0]

5900 [1.7]

2

34800 [10.2]

12200 [3.6]

1

20450 [6.0]

5950 [1.7]

2

33750 [9.9]

11750 [3.4]

1

20650 [6.1]

5950 [1.7]

2

33800 [9.9]

11700 [3.4]

1

20800 [6.1]

6000 [1.8]

2

33900 [9.9]

12100 [3.5]

1

18450 [5.4]

6550 [1.9]

2

33400 [9.8]

12100 [3.5]

1

18100 [5.3]

6700 [2.0]

2

31550 [9.2]

13450 [3.9]

1

18450 [5.4]

6550 [1.9]

2

34050 [10.0]

11950 [3.5]

1

20600 [6.0]

6000 [1.8]

2

33900 [9.9]

12100 [3.5]

1

20650 [6.1]

5950 [1.7]

2

33750 [9.9]

11750 [3.4]

1

20800 [6.1]

6000 [1.8]

2

34200 [10.0]

12300 [3.6]

1

20800 [6.1]

6000 [1.8]

2

34200 [10.0]

12300 [3.6]

1

20800 [6.1]

6000 [1.8]

2

34000 [10.0]

12000 [3.5]

1

20800 [6.1]

6000 [1.8]

2

34200 [10.0]

12300 [3.6]

1

19800 [5.8]

5600 [1.6]

2

32850 [9.6]

11650 [3.4]

1

19900 [5.8]

5700 [1.7]

2

33450 [9.8]

12050 [3.5]

1

19750 [5.8]

5650 [1.7]

2

33450 [9.8]

12050 [3.5]

1

20100 [5.9]

5700 [1.7]

2

33750 [9.9]

12250 [3.6]

1

20450 [6.0]

5950 [1.7]

2

33300 [9.8]

12700 [3.7]

1

20650 [6.1]

5950 [1.7]

2

33900 [9.9]

12100 [3.5]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

46000 [13.5]
46000 [13.5]
46000 [13.5]
47000 [13.8]
45500 [13.3]
45500 [13.3]

15
15.5
14.5
17.5
16
16

11.5
11.5
11.5
13
11.5
11.5

46000 [13.5]

16.5

11.5

45500 [13.3]

16.5

11.5

45000 [13.2]
46000 [13.5]
46000 [13.5]
45500 [13.3]
46500 [13.6]
46500 [13.6]
46000 [13.5]

17
17
16.5
16
17
16.5
16.5

11.5
11.5
11.5
11.5
12
12
12

46500 [13.6]

17

12

44500 [13.0]

15.5

11

45500 [13.3]
45500 [13.3]

16
16

11.5
11.5

46000 [13.5]

16.5

12

46000 [13.5]

15

11.5

46000 [13.5]

15.5

11.5

Sound
Rating
dB

1200 [566]

73

1400 [661]

74

1175 [554]

73

1600 [755]

74

1175 [554]

73

1550 [731]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

775 [366]

73

1600 [755]

74

725 [342]

73

1400 [661]

74

775 [366]

73

1625 [767]

74

1225 [578]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1200 [566]

73

1575 [743]

74

1225 [578]

73

1600 [755]

74

1225 [578]

73

1625 [767]

74

1200 [566]

73

1625 [767]

74

1050 [495]

73

1400 [661]

74

1075 [507]

73

1400 [661]

74

1025 [484]

73

1425 [672]

74

1075 [507]

73

1425 [672]

74

1200 [566]

73

1400 [661]

74

1175 [554]

73

1600 [755]

74

[ ] Designates Metric Conversions

35

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

048JEC

RCQD-4824
RCQD-4824+RXMD-C06
RCSL-H*4824

RCSN-H*6024 ➀

ID Air Mover

ROLA-115E05
Coil Only
RHPL-HM4824

RHPN-HM6024

RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?
RGGE-09?ZCM?
060JEC

RGGE-10?ZCM?
RCFL-H*6024

RGGE-12?RCM?
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-10?ZAJ?
RGRM-12?RAJ?
RGTM-07?RBG?

1

20800 [6.1]

6000 [1.8]

2

34050 [10.0]

11950 [3.5]

1

21400 [6.3]

4500 [1.3]

2

33600 [9.8]

12400 [3.6]

1

18800 [5.5]

7200 [2.1]

2

30900 [9.1]

15100 [4.4]

1

23600 [6.9]

8800 [2.6]

2

39100 [11.5]

17900 [5.2]

1 - dehumid

22100 [6.5]

10300 [3.0]

2 - dehumid

36200 [10.6]

20800 [6.1]

1

23500 [6.9]

9100 [2.7]

2

38250 [11.2]

17750 [5.2]

1

23450 [6.9]

9150 [2.7]

2

38100 [11.2]

17400 [5.1]

1

23600 [6.9]

9200 [2.7]

2

38550 [11.3]

17950 [5.3]

1

22550 [6.6]

9250 [2.7]

2

41050 [12.0]

15450 [4.5]

1

24300 [7.1]

8300 [2.4]

2

37800 [11.1]

18200 [5.3]

1

24550 [7.2]

8250 [2.4]

2

37450 [11.0]

18550 [5.4]

1

23600 [6.9]

9200 [2.7]

2

38400 [11.3]

17600 [5.2]

1

23450 [6.9]

9150 [2.7]

2

38250 [11.2]

17750 [5.2]

1

24050 [7.0]

9350 [2.7]

2

38750 [11.4]

17750 [5.2]

1

23600 [6.9]

9200 [2.7]

2

38400 [11.3]

17600 [5.2]

1

23450 [6.9]

9150 [2.7]

2

38250 [11.2]

17750 [5.2]

1

24050 [7.0]

9350 [2.7]

2

38750 [11.4]

17750 [5.2]

1

23800 [7.0]

9200 [2.7]

2

38650 [11.3]

17850 [5.2]

1

23600 [6.9]

9200 [2.7]

2

38800 [11.4]

17700 [5.2]

1

23400 [6.9]

8800 [2.6]

2

37950 [11.1]

17550 [5.1]

1

23850 [7.0]

8950 [2.6]

2

38350 [11.2]

17650 [5.2]

1

23900 [7.0]

9300 [2.7]

38700 [11.3]

17800 [5.2]

2
➀ Highest sales volume tested combination required by D.O.E. test procedures.

36

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

46000 [13.5]
46000 [13.5]
46000 [13.5]

57000 [16.7]

16
14.5
17

18

12
11.5
12.5

12

Sound
Rating
dB

1200 [566]

73

1600 [755]

74

1200 [566]

73

1600 [755]

74

1250 [590]

73

1625 [767]

74

1050 [495]

67

1700 [802]

72

925 [437]
1325 [625]

56000 [16.4]
55500 [16.3]
56500 [16.6]
56500 [16.6]
56000 [16.4]

16
15.5
16
16
15.5

11
11
11.5
10.5
11

56000 [16.4]

16

11.5

56000 [16.4]

16

11.5

56000 [16.4]
56500 [16.6]
56000 [16.4]
56000 [16.4]
56500 [16.6]
56500 [16.6]
56500 [16.6]
55500 [16.3]
56000 [16.4]
56500 [16.6]

16
16
16
16
16
16.5
16.5
16
16
16

11.5
11.5
11.5
11.5
11.5
11.5
12
11
11.5
11.5

1200 [566]

67

1600 [755]

72

1225 [578]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

975 [460]

67

1950 [920]

72

1200 [566]

67

1650 [779]

72

1225 [578]

67

1625 [767]

72

1225 [578]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1375 [649]

67

1750 [826]

72

1225 [578]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1375 [649]

67

1750 [826]

72

1225 [578]

67

1625 [767]

72

1200 [566]

67

1625 [767]

72

1150 [543]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1325 [625]

67

1675 [790]
72
[ ] Designates Metric Conversions

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGTM-09?ZAJ?
RGTM-10?RBJ?
RCFL-H*6024
ROLA-070E04
ROLA-115E05
RCFL-H*6024+RXMD-C06

Coil Only
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?

060JEC

RGGE-09?ZCM?
RGGE-10?ZCM?
RGGE-12?RCM?
RCFN-H*6024
RGJF-09?ZCM?
RGJF-10?ZCM?
RGJF-12?RCM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-12?RAJ?
RGTM-07?RBG?
RGTM-09?ZAJ?

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

1

23600 [6.9]

9200 [2.7]

2

38200 [11.2]

17800 [5.2]

1

23750 [7.0]

9250 [2.7]

2

38600 [11.3]

17900 [5.2]

1

23700 [6.9]

8900 [2.6]

2

38200 [11.2]

17300 [5.1]

1

23850 [7.0]

8950 [2.6]

2

38550 [11.3]

17450 [5.1]

1

22400 [6.6]

9000 [2.6]

2

38500 [11.3]

18000 [5.3]

1

23700 [6.9]

8900 [2.6]

2

38250 [11.2]

17250 [5.1]

1

23650 [6.9]

8950 [2.6]

2

38100 [11.2]

17400 [5.1]

1

23850 [7.0]

8950 [2.6]

2

38350 [11.2]

17650 [5.2]

1

24400 [7.1]

8200 [2.4]

2

36950 [10.8]

18550 [5.4]

1

24400 [7.1]

8200 [2.4]

2

37850 [11.1]

18150 [5.3]

1

24800 [7.3]

8000 [2.3]

2

37600 [11.0]

18400 [5.4]

1

23850 [7.0]

8950 [2.6]

2

38400 [11.3]

17600 [5.2]

1

23700 [6.9]

8900 [2.6]

2

38250 [11.2]

17250 [5.1]

1

23250 [6.8]

8750 [2.6]

2

39050 [11.4]

17950 [5.3]

1

24300 [7.1]

9100 [2.7]

2

38500 [11.3]

17500 [5.1]

1

24100 [7.1]

9100 [2.7]

2

38500 [11.3]

17500 [5.1]

1

24250 [7.1]

9150 [2.7]

2

38800 [11.4]

17700 [5.2]

1

24000 [7.0]

9000 [2.6]

2

38500 [11.3]

17500 [5.1]

1

24000 [7.0]

9000 [2.6]

2

38650 [11.3]

17850 [5.2]

1

23800 [7.0]

9000 [2.6]

2

38800 [11.4]

17700 [5.2]

1

23850 [7.0]

8950 [2.6]

2

38350 [11.2]

17650 [5.2]

1

24150 [7.1]

9050 [2.7]

2

38650 [11.3]

17850 [5.2]

1

24000 [7.0]

9000 [2.6]

2

38200 [11.2]

17300 [5.1]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

56000 [16.4]
56500 [16.6]
55500 [16.3]
56000 [16.4]
56500 [16.6]
55500 [16.3]

16
16
15.5
16
15
16

11.5
11.5
11.5
11.5
11.5
11

55500 [16.3]

16

11

56000 [16.4]

16.5

11.5

55500 [16.3]
56000 [16.4]
56000 [16.4]
56000 [16.4]
55500 [16.3]
57000 [16.7]
56000 [16.4]

16
16
16.5
16.5
16
16.5
15.5

11
11
11.5
11.5
11
11
11

56000 [16.4]

15

11

56500 [16.6]

16

11.5

56000 [16.4]
56500 [16.6]

16.5
16.5

11.5
11.5

56500 [16.6]

17

12

56000 [16.4]

16

11.5

56500 [16.6]
55500 [16.3]

16
16

11.5
11.5

Sound
Rating
dB

1250 [590]

67

1600 [755]

72

1275 [602]

67

1675 [790]

72

1175 [554]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1250 [590]

67

1675 [790]

72

1200 [566]

67

1600 [755]

72

1225 [578]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1200 [566]

67

1600 [755]

72

1200 [566]

67

1650 [779]

72

1225 [578]

67

1625 [767]

72

1225 [578]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1000 [472]

67

1950 [920]

72

1400 [661]

67

1775 [838]

72

1400 [661]

67

1775 [838]

72

1375 [649]

67

1750 [826]

72

1225 [578]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1200 [566]

67

1625 [767]

72

1225 [578]

67

1625 [767]

72

1325 [625]

67

1675 [790]

72

1250 [590]

67

1600 [755]

72

[ ] Designates Metric Conversions

37

Air

Performance Data
RASL- JEC Series

Performance Data @ AHRI Standard Conditions—Cooling
Outdoor
Unit
RASL-

Model Numbers
Stage
ID Coil

Rev.
5/8/2012

ID Air Mover

RGTM-10?RBJ?
RCFN-H*6024

ROLA-070E04
ROLA-115E05

RCFN-H*6024+RXMD-C06

Coil Only
RBHM-26J*
RGFE-09?ZCM?
RGFE-10?ZCM?
RGFE-12?RCM?
RGFG-09?ZCM?
RGFG-10?ZCM?
RGFG-12?RCM?

060JEC

RGJF-09?ZCM?
RGJF-10?ZCM?
RCQD-6024
RGJF-12?RCM?
RGPE-07?BRQ?
RGPE-10?BRM?
RGPE-12?ARM?
RGRM-09?ZAJ?
RGRM-10?ZAJ?
RGRM-12?RAJ?
ROLA-070E04
ROLA-115E05
RCQD-6024+RXMD-C06

Coil Only

1

23950 [7.0]

9050 [2.7]

2

38800 [11.4]

17700 [5.2]

1

23700 [6.9]

8900 [2.6]

2

38200 [11.2]

17300 [5.1]

1

23850 [7.0]

8950 [2.6]

2

38550 [11.3]

17450 [5.1]

1

24400 [7.1]

7900 [2.3]

2

38500 [11.3]

18000 [5.3]

1

22500 [6.6]

9300 [2.7]

2

36800 [10.8]

17700 [5.2]

1

21550 [6.3]

9250 [2.7]

2

35500 [10.4]

17000 [5.0]

1

21550 [6.3]

9250 [2.7]

2

35350 [10.4]

16650 [4.9]

1

21700 [6.4]

9300 [2.7]

2

35600 [10.4]

16900 [5.0]

1

22150 [6.5]

8450 [2.5]

2

34100 [10.0]

17900 [5.2]

1

22150 [6.5]

8450 [2.5]

2

35150 [10.3]

17350 [5.1]

1

22600 [6.6]

8400 [2.5]

2

34800 [10.2]

17700 [5.2]

1

21700 [6.4]

9300 [2.7]

2

35650 [10.4]

16850 [4.9]

1

21550 [6.3]

9250 [2.7]

2

35500 [10.4]

17000 [5.0]

1

21700 [6.4]

9300 [2.7]

2

35800 [10.5]

16700 [4.9]

1

21650 [6.3]

9350 [2.7]

2

35750 [10.5]

16750 [4.9]

1

21650 [6.3]

9350 [2.7]

2

35900 [10.5]

17100 [5.0]

1

21700 [6.4]

9300 [2.7]

2

36050 [10.6]

16950 [5.0]

1

21900 [6.4]

9100 [2.7]

2

35600 [10.4]

16900 [5.0]

1

21600 [6.3]

9000 [2.6]

2

35400 [10.4]

17100 [5.0]

1

21850 [6.4]

9150 [2.7]

2

35850 [10.5]

17150 [5.0]

1

21550 [6.3]

9250 [2.7]

2

35450 [10.4]

17550 [5.1]

1

21700 [6.4]

9300 [2.7]

2

35800 [10.5]

17200 [5.0]

1

20400 [6.0]

9100 [2.7]

2

35600 [10.4]

17400 [5.1]

➀ Highest sales volume tested combination required by D.O.E. test procedures.

38

Net
Sensible
BTU/H [kW]

AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Ratings
Net
Indoor
Latent
Airflow
Total Capacity
SEER EER
BTU/H [kW]
CFM [L/s]
BTU/H [kW]

56500 [16.6]
55500 [16.3]
56000 [16.4]
56500 [16.6]
54500 [16.0]
52500 [15.4]

16.5
15.5
16
15
16.5
15

11.5
11.5
11.5
11.5
12
10.5

52000 [15.2]

15

10.5

52500 [15.4]

15.5

11

52000 [15.2]
52500 [15.4]
52500 [15.4]
52500 [15.4]
52500 [15.4]
52500 [15.4]
52500 [15.4]

15
15
15
15
15
15.5
15.5

10.5
10.5
11
11
10.5
11
11

53000 [15.5]

15.5

11

53000 [15.5]

16

11

52500 [15.4]
52500 [15.4]

14.5
15

10.5
10.5

53000 [15.5]

15

11

53000 [15.5]

14.5

10.5

53000 [15.5]
53000 [15.5]

15
14

11
11

Sound
Rating
dB

1275 [602]

67

1675 [790]

72

1175 [554]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1250 [590]

67

1680 [793]

72

1275 [602]

67

1700 [802]

72

1200 [566]

67

1600 [755]

72

1225 [578]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1200 [566]

67

1600 [755]

72

1200 [566]

67

1650 [779]

72

1225 [578]

67

1625 [767]

72

1225 [578]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1200 [566]

67

1575 [743]

72

1225 [578]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1200 [566]

67

1625 [767]

72

1225 [578]

67

1625 [767]

72

1150 [543]

67

1600 [755]

72

1225 [578]

67

1625 [767]

72

1175 [554]

67

1600 [755]

72

1200 [566]

67

1600 [755]

72

1275 [602]

67

1700 [802]

72

[ ] Designates Metric Conversions

Air

Electrical and Physical Data
RASL- JEC Series

Electrical and Physical Data
ELECTRICAL

PHYSICAL

Model
Compressor
Fuse or HACR
Fan Motor Minimum
Outdoor Coil
Phase
Number
Circuit Breaker
Full Load Circuit
Rated
Load
Locked
Rotor
16AJL Frequency (Hz) Amperes
Amperes Amperes Ampacity Minimum Maximum Face Area No.
Voltage (Volts)
(FLA) Amperes Amperes Amperes Sq. Ft. [m2] Rows CFM [L/s]
(RLA)
(LRA)

Refrig.
Per
Circuit
Oz. [g]

Weight
Net
Lbs. [kg]

Shipping
Lbs. [kg]

Rev. 5/8/2012
025JEC 1-60-208/230

11.7/11.7

58.3

2.8

18/18

25/25

25/25

15.8 [1.47]

1

2500 [1180] 138 [3912] 206

[93.4] 219

[93.4]

037JEC 1-60-208/230

15.3/15.3

83

2.8

22/22

30/30

35/35

23.01 [2.14]

1

3400 [1604] 186 [5273] 216

[98] 229

[98]

039JEC 1-60-208/230

17.9/17.9

96

2.8

26/26

30/30

40/40

23

[2.14]

2

3500 [1652] 268 [7598] 326

[147.9] 345 [147.9]

048JEC 1-60-208/230

26.9/26.9

117

2.8

37/37

45/45

60/60

23

[2.14]

2

3500 [1652] 253 [7173] 326

[147.9] 348 [147.9]

060JEC 1-60-208/230

28.2/28.2

146

2.8

39/39

50/50

60/60

23

[2.14]

2

3500 [1652] 241 [6832] 328

[148.8] 346 [148.8]

NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
[ ] Designates Metric Conversions

39

Air

Unit Dimensions
RASL- JEC Series

Unit Dimensions
Model Number
RASL025JEC/037JEC/039JEC/
048JEC/060JEC

Height “H”
(Inches) [mm]

Length “L”
(Inches) [mm]

Width “W”
(Inches) [mm]

33 [838]

443/8 [1127]

311/2 [800]

[ ] Designates Metric Conversions

AIR DISCHARGE
ALLOW 60 [1524 mm] CLEARANCE

W

L
H

LOW VOLTAGE
CONNECTION
7/80 [22 mm]

ACCESS
PANEL
AIR INLETS
(LOUVERS)
ALLOW 6 [152 mm]
MIN. CLEARANCE
3 SIDES
ALTERNATE HIGH VOLTAGE
CONNECTION (KNOCKOUT)
111/32 [34 mm]

SERVICE
FITTINGS

HIGH VOLTAGE
CONNECTION
111/320 [34 mm]

ALLOW 24 [610 mm]
ACCESS CLEARANCE

003
A-00

VAPOR LINE
CONNECTION

HIGH PRESSURE
CONTROL
MANUAL RESET
(FIELD INSTALLED
ACCESSORY)

40

LIQUID LINE
CONNECTION
SERVICE ACCESS
TO ELECTRICAL &
27/80 [73 mm] DIA. VALVES ALLOW
ACCESSORY
240 [610 mm]
KNOCKOUTS
CLEARANCE
ONE SIDE

Air

Refrigerant Line Size Information
RASL- JEC Series

Condensing Unit Refrigerant Line Size Information
Liquid Line Sizing (2-Stage R-410A)

R-410A
System
Capacity
Model

Line Size
Connection
Size
(Inch I.D.)
[mm]

-025

3/8″
[9.53]
3/8″
[9.53]

-037

-039

-048

-060

Line Size
(Inch O.D.)
[mm]

3/8″
[9.53]
3/8″
[9.53]
3/8″
[9.53]

Liquid Line Size
Outdoor Unit Above Indoor Coil
(Cooling Only - Does not apply to Heat Pumps)
Total Equivalent Length—Feet [m]
75
100
125
[22.86]
[30.48]
[38.10]
Minimum Vertical Separation—Feet [m]
10 [3.05]
34 [10.36]
58 [17.68]
0
0
0

25
[7.62]

50
[15.24]

150
[45.72]

1/4" [6.35]*
5/16" [7.93]*

0
0

0
0

3/8" [9.52]*

0

0

0

0

0

0

5/16" [7.93]*
3/8" [9.52]*

0
0

0
0

6 [1.83]
0

14 [4.27]
0

21 [6.40]
0

28 [8.53]
0

1/2" [12.70]*

0

0

0

0

0

0

5/16" [7.93]*
3/8" [9.52]*

0
0

0
0

0
0

0
0

10 [3.05]
0

24 [7.32]
0

1/2" [12.70]*

0

0

0

0

0

0

5/16" [7.93]*

0

0

0

18 [5.49]

40 [12.19]

62 [18.90]

3/8" [9.52]*

0

0

0

0

0

0

1/2" [12.70]*

0

0

0

0

0

0

3/8" [9.52]*
1/2" [12.70]*

0
0

0
0

0
0

0
0

0
0

0
0

82 [24.99]
0

Liquid Line Sizing (2-Stage R-410A)

R-410A
System
Capacity
Model

Line Size
Connection
Size
(Inch I.D.)
[mm]

Line Size
(Inch O.D.)
[mm]

1/4" [6.35]*

25 [11.28]

-025

3/8″
[9.53]

Liquid Line Size
Outdoor Unit Below Indoor Coil
(Cooling Only - Does not apply to Heat Pumps)
Total Equivalent Length—Feet [m]
50
75
100
125
[15.24]
[22.86]
[30.48]
[38.10]
Maximum Vertical Separation—Feet [m]
13 [3.96]
N/A
N/A
N/A

5/16" [7.93]*

25 [14.33]

44 [13.41]

40 [12.19]

36 [10.97]

30 [9.14]

24 [7.32]

3/8″
[9.53]

3/8" [9.52]*
5/16" [7.93]*
3/8" [9.52]*

25 [15.24]
N/A
12 [3.66]

48 [14.63]
N/A
9 [2.74]

47 [14.33]
N/A
N/A

46 [14.02]
N/A
N/A

45 [13.72]
N/A
N/A

43 [13.11]
N/A
N/A

1/2" [12.70]*

14 [4.27]

13 [3.96]

13 [3.96]

12 [3.66]

12 [3.66]

11 [3.35]

5/16" [7.93]*
3/8" [9.52]*

15 [4.57]
18 [5.49]

11 [3.35]
17 [5.18]

N/A
15 [4.57]

N/A
13 [3.96]

N/A
12 [3.66]

N/A
10 [3.05]

1/2" [12.70]*

20 [6.10]

19 [5.79]

19 [5.79]

19 [5.79]

18 [5.49]

18 [5.49]

5/16" [7.93]*

25 [10.36]

24 [7.32]

N/A

N/A

N/A

N/A

3/8" [9.52]*

25 [11.89]

36 [10.97]

34 [10.36]

32 [9.75]

29 [8.84]

23 [7.01]

1/2" [12.70]*

25 [12.50]

40 [12.19]

40 [12.19]

39 [11.89]

39 [11.89]

38 [11.58]

3/8" [9.52]*
1/2" [12.70]*

25 [11.28]
25 [11.89]

33 [10.06]
39 [11.89]

30 [9.14]
38 [11.58]

25 [7.62]
37 [11.28]

15 [4.57]
37 [11.28]

N/A
36 [10.97]

-037

-039

3/8″
[9.53]

-048

3/8″
[9.53]

-060

3/8″
[9.53]

25
[7.62]

150
[45.72]
N/A

NOTES: N/A = Application not recommended.
*Standard line size.
[ ] Designates Metric Conversions

41

Air

Refrigerant Line Size Information
RASL- JEC Series

Condensing Unit Refrigerant Line Size Information (Con’t.)
R-410A
System
Capacity
Model

Line Size
Connection Size
(Inch I.D.) [mm]

-025

3/4"
[19.05]

-037/-039

-048

3/4"
[19.05]
7/8"
[22.23]

SUCTION LINE SIZE - OUTDOOR UNIT ABOVE INDOOR COIL
Suction Line Size
Line Size
Outdoor Unit ABOVE Indoor Coil (Cooling Only - Does not apply to Heat Pumps)
(Inch O.D.)
Total Equivalent Length - Feet [m]
[mm]
25 [7.62]
50 [15.24]
75 [22.86]
100 [30.48]
125 [45.72]
150 [45.72]
5/8" [15.88]*
Same as Liquid Line Size Table
3/4" [19.05]*
N/A
7/8" [22.23]*

N/A

5/8" [15.88]*
3/4" [19.05]*

Same as Liquid Line Size Table
N/A

7/8" [22.23]*

N/A

5/8" [15.88]*
3/4" [19.05]*

Same as Liquid Line Size Table
Same as Liquid Line Size Table

7/8" [22.23]*
-060

7/8"
[22.23]

R-410A
System
Capacity
Model

Line Size
Connection Size
(Inch I.D.) [mm]

-025

3/4"
[19.05]

-037/-039

-048

3/4"
[19.05]
7/8"
[22.23]

3/4" [19.05]*
7/8" [22.23]*
1-1/8" [28.58]*

N/A
Same as Liquid Line Size Table
N/A
N/A

SUCTION LINE SIZE - OUTDOOR UNIT BELOW INDOOR COIL
Suction Line Size
Line Size
Outdoor Unit BELOW Indoor Coil (Cooling Only - Does not apply to Heat Pumps)
(Inch O.D.)
Total Equivalent Length - Feet [m]
[mm]
25 [7.62]
50 [15.24]
75 [22.86]
100 [30.48]
125 [45.72]
150 [45.72]
5/8" [15.88]*
Same as Liquid Line Size Table
3/4" [19.05]*
Same as Liquid Line Size Table
N/A
7/8" [22.23]*

N/A

5/8" [15.88]*
3/4" [19.05]*

Same as Liquid Line Size Table
Same as Liquid Line Size Table

7/8" [22.23]*

N/A

5/8" [15.88]*
3/4" [19.05]*

Same as Liquid Line Size Table
Same as Liquid Line Size Table

7/8" [22.23]*

Same as Liquid Line Size Table

3/4" [19.05]*
Same as Liquid Line Size Table
7/8"
-060
7/8" [22.23]*
Same as Liquid Line Size Table
[22.23]
1-1/8"
[28.58]*
NOTES: Using suction line larger than shown in chart will result in poor oil return. N/A = Application not recommended. N/A
*Standard line size.
[ ] Designates Metric Conversions

42

N/A

Air

Refrigerant Line Size Information
RASL- JEC Series

Vapor Line Capacity Multiplier
RASL
Unit Vapor Line Connection Size
(Inches I.D.) [mm]

025
3/4" [19.05]
I.D. Sweat

037
039
048
3/4" [19.05]
7/8" [22.23]
7/8" [22.23]
I.D. Sweat
I.D. Sweat
I.D. Sweat
Vapor Line Diameter (inches O.D.) [mm]
5/8" [15.88]
5/8" [15.88]
5/8" [15.88]
Optional
Optional
Optional
3/4" [19.05]
3/4" [19.05]
3/4" [19.05]
Standard
Standard
Standard
0.99
0.99
0.98
1.00
1.00
1.00

060
7/8" [22.23]
I.D. Sweat

25' [7.62]

Optional
Standard

5/8" [15.88]
Optional
3/4" [19.05]
Standard
1.00
1.00

50'[15.24]

Optional
Standard

0.98
1.00

0.98
1.00

0.97
0.99

0.96
0.99

0.98
0.99

75' [22.86]

Optional
Standard

0.98
1.00

0.96
0.99

0.96
0.99

0.94
0.98

0.96
0.96

100' [22.86]

Optional
Standard

0.98
N/A

0.95
N/A

0.95
N/A

0.92
N/A

0.95
N/A

125' [38.10]

Optional
Standard

0.96
N/A

0.94
N/A

0.93
N/A

0.90
N/A

0.94
N/A

150' [45.72]

Optional
Standard

0.96
N/A

0.92
N/A

0.91
N/A

0.88
N/A

0.93
N/A

Vapor Line Run Feet [m]

3/4" [19.05]
Optional
7/8" [22.23]
Standard
0.99
1.00

NOTES:
1. Do NOT exceed the limits in the liquid and suction line sizing charts.
2. Do NOT use 7/8 OD suction lines in 2, 3, or 4-ton applications.
3. Do NOT use 1-1/8 OD suction line in ANY application.
4. Line sets over 75 feet MUST use the optional suction line.
[ ] Designates Metric Conversions

43

Air

Limited Warranty
RASL- JEC Series

GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.

44

Conditional Unit Replacement
(Registration Required) ...............................Ten (10) Years
Parts ............................................................Ten (10) Years

Air

Notes
RASL- JEC Series

45

Air

46

Notes
RASL- JEC Series

Air

Notes
RASL- JEC Series

47

The new degree of comfort.™

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com

Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5

PRINTED IN U.S.A 06/12 QG FORM NO. A11-211



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 9.5.0 (Macintosh)
Create Date                     : 2012:06:19 11:37:52-05:00
Modify Date                     : 2012:06:19 15:30:57-05:00
Title                           : untitled
Has XFA                         : No
Page Count                      : 48
EXIF Metadata provided by EXIF.tools

Navigation menu