Rheem Prestige Series Single Stage Specification Sheet
2015-04-02
: Rheem Rheem-Prestige-Series-Single-Stage-Specification-Sheet-683646 rheem-prestige-series-single-stage-specification-sheet-683646 rheem pdf
Open the PDF directly: View PDF
.
Page Count: 36
| Download | |
| Open PDF In Browser | View PDF |
Air Air Conditioners RAPM- JEZ Series Rheem Prestige Series™ equipped with Comfort Control System™ RAPM- JEZ Series Efficiencies up to 16 SEER/13.55 EER Nominal Sizes 1.5 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 18.8 to 62.5 kBTU [5.50 to 18.32 kW] 16.0 “Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Contractor for details or visit www.energystar.gov.” • The Comfort Control System™ provides on-board diagnostics and fault history for condensing units with single-phase compressors by detecting system and electrical problems without adding sensors. It can also communicate “fault codes” to enabled “L terminal” thermostats. The integrated diagnostics with Active Protection™ prevents compressor operation when potentially harmful conditions are detected. • 7-Segment LED Display is exclusive only to Rheem products. The information-display quickly and accurately shows technicians the source of malfunctions. • Features a five-year conditional unit replacement warranty when properly installed with a new Rheem Air Handler or Rheem Indoor Coil with a Rheem Gas Furnace. See product warranty card for additional information. • Compressor sound blanket is standard to provide quiet operation. • Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all-weather protection. • Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction. • Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. • Removable top grille provides access to the condenser fan motor and condenser coil. • Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. • All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus. FORM NO. A11-214 Air Table of Contents RAPM- JEZ Series TABLE OF CONTENTS Model Features ........................................................................................................3 Model Number Identification ............................................................................4 Accessories....................................................................................................4 Scroll Compressor ..........................................................................................4 Performance Data ......................................................................................5-30 Electrical & Physical Data ..............................................................................31 Unit Dimensions............................................................................................32 Refrigerant Line Size Information ....................................................................33 Limited Warranty ..........................................................................................34 2 Air Model Features RAPM- JEZ Series The Comfort Control System ™ Features: ■ The Rheem exclusive 7-Segment LED Display easily shows system operating status codes and diagnostic codes. ■ A Sealed Switch replaces the standard contactor and features optical control and latching mechanism. The sealed switch prevents infiltration of insects and dust. A minimal switching arc, by the optical control, offers greater reliability. The latching mechanism consumes less power while reducing chatter. ■ The Status Indication and System Diagnostics feature thermostat communication capability, built-in diagnostics, high & low voltage monitoring and high & low pressure switch monitoring. The thermostat communication capability alerts the homeowner to any necessary service requirements. Faster, more accurate service is provided by the built-in diagnostics, by providing the HVAC professional with dependable information. With the high and low voltage monitoring feature, the control provides alerts for out-of-range conditions. In addition, high and low pressure-switch monitoring prevents the system from operating outside of its normal parameters. ■ The fault recall feature will allow for the last six fault-codes to be displayed, and will retain these codes even if power failure occurs. ■ Built-in short-cycle protection allows the compressor to restart easily without oil removal. ■ A 30-second minimum run-time for every compressor call enables the oil return to the compressor. ■ Active Protection monitors the system to prevent nuisance lockouts and prevents compressor operation when potentially harmful conditions are detected. ■ The compressor and fan are controlled independently, which reduces the starting load and light dimming. ■ A push-button is offered to operate the compressor and fan for 5 seconds to allow for an operation check. ■ In order to save time and money, replacement automotive fuses can be utilized instead of replacing the entire control board. Standard Features RAPM- JEZ Condensing Units 1. This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 3. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. 4. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. 5. Cabinet is constructed of powder painted galvanized steel. The full wrap-around louvered grille protects the coil from damage. 6. Enhanced compressor sound blanket is standard. 7. Copper tube—aluminum fin coils are used on all models. 8. The control box is located in the top corner of the cabinet providing for easy access through a service panel. 9. Service valves are standard on all models. 10. Field connections for power and control wiring are kept separate. 11. Every unit is factory charged and run-tested. 12. Separate compressor compartment for easy service access. 13. Drawn, painted base pan for extra corrosion resistance and sound reduction. 14. The RAPM- JEZ has a 10 year limited compressor warranty, plus a 5 year conditional unit replacement warranty. See General Terms of Limited Warranty for more details. 15. Hard Start Kits—Standard on all JEZ models. 16. Control Box Cover. 17. Automatic reset high and low pressure controls are standard on all JEZ models. 18. Liquid line filter drier is standard on all models (shipped – not installed). 3 Air Model I.D./Accessories/Compressor RAPM- JEZ Series Model Number Identification R A P M RHEEM REMOTE CONDENSING UNIT P = 14 SEER — A* 018 VARIATIONS J E Z DESIGN SERIES A =COOLING STANDARD ELECTRICAL DESIGNATION VARIATIONS M = R-410A (2ND DESIGN SERIES) 018 = 18,000 BTU/HR [5.28 kW] 024 = 24,000 BTU/HR [7.03 kW] 030 = 30,000 BTU/HR [8.79 kW] 036 = 36,000 BTU/HR [10.55 kW] 042 = 42,000 BTU/HR [12.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 056 = 56,000 BTU/HR [16.41 kW] 060 = 60,000 BTU/HR [17.58 kW] COOLING CONNECTION FITTING CAPACITY Accessories • Low Ambient Control (RXAD-A08) • Crankcase Heater Thermostats 200-Series * Programmable 300-Series * Deluxe Programmable 500-Series * Communicating/ Programmable 400-Series * Special Applications/ Programmable * Photos are representative. Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T11-001. Scroll® Compressor The reliable scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, reducing start problems in the field. And its unique design enables air conditioners to perform efficiently and quietly. [ ] Designates Metric Conversions 4 J = 208/230V-1-60 EQUIPPED WITH THE COMFORT CONTROL SYSTEM ™ Z = SWEAT W/SCROLL Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 650 [307] 650 [307] 575 [271] 600 [283] 575 [271] 600 [283] 625 [295] 575 [271] 600 [283] 675 [319] 575 [271] 625 [295] 650 [307] 625 [295] 575 [271] 600 [283] 625 [295] 625 [295] 600 [283] 600 [283] 650 [307] 650 [307] 575 [271] 600 [283] 575 [271] 600 [283] 625 [295] 575 [271] 625 [295] 575 [271] 600 [283] 675 [319] 575 [271] 625 [295] 650 [307] 625 [295] 575 [271] 600 [283] 625 [295] 625 [295] 600 [283] 600 [283] 650 [307] 575 [271] 600 [283] 575 [271] 600 [283] 625 [295] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] 18,900 [5.5] RCFL-H*2417+RXMD-C04 ➀ RCFL-A*2414+RXMD-C04 18,800 [5.5] RCFL-A*2417(RGFE-06?MCK?) 18,900 [5.5] RCFL-A*2417(RGFE-07?MCK?) 19,100 [5.6] RCFL-A*2417(RGFG-06?MCK?) 19,000 [5.6] RCFL-A*2417(RGFG-07?MCK?) 19,100 [5.6] RCFL-A*2417(RGGE-06?MCK?) 19,300 [5.7] RCFL-A*2417(RGGE-07?MCK?) 19,000 [5.6] RCFL-A*2417(RGLE-07?AMK?) 19,100 [5.6] RCFL-A*2417(RGLT-07?AMK?) 19,400 [5.7] RCFL-A*2417(RGPE-05?BMK?) 18,900 [5.5] RCFL-A*2417(RGPE-07?AMK?) 19,400 [5.7] RCFL-A*2417(RGPT-05?BMK?) 19,300 [5.7] RCFL-A*2417(RGPT-07?AMK?) 19,400 [5.7] RCFL-A*2417(RGRM-04?MAE?) 18,900 [5.5] RCFL-A*2417(RGRM-06?MAE?) 19,100 [5.6] RCFL-A*2417(RGRM-07?MAE?) 19,300 [5.7] RCFL-A*2417(RGTM-06?MAE?) 19,300 [5.7] RCFL-A*2417(ROCA-070E03) 19,100 [5.6] RCFL-A*2417(ROLA-070E03) 19,100 [5.6] RCFL-A*2417+RXMD-C04 18,900 [5.5] RCFL-H*2414+RXMD-C04 18,800 [5.5] RCFL-H*2417(RGFE-06?MCK?) 18,900 [5.5] RCFL-H*2417(RGFE-07?MCK?) 19,100 [5.6] 018JEZ RCFL-H*2417(RGFG-06?MCK?) 19,000 [5.6] RCFL-H*2417(RGFG-07?MCK?) 19,100 [5.6] RCFL-H*2417(RGGE-06?MCK?) 19,300 [5.7] RCFL-H*2417(RGGE-07?MCK?) 19,000 [5.6] RCFL-H*2417(RGJF-06?MCK?) 19,300 [5.7] RCFL-H*2417(RGJF-07?MCK?) 19,000 [5.6] RCFL-H*2417(RGLE-07?AMK?) 19,100 [5.6] RCFL-H*2417(RGLT-07?AMK?) 19,400 [5.7] RCFL-H*2417(RGPE-05?BMK?) 18,900 [5.5] RCFL-H*2417(RGPE-07?AMK?) 19,400 [5.7] RCFL-H*2417(RGPT-05?BMK?) 19,300 [5.7] RCFL-H*2417(RGPT-07?AMK?) 19,400 [5.7] RCFL-H*2417(RGRM-04?MAE?) 18,900 [5.5] RCFL-H*2417(RGRM-06?MAE?) 19,100 [5.6] RCFL-H*2417(RGRM-07?MAE?) 19,300 [5.7] RCFL-H*2417(RGTM-06?MAE?) 19,300 [5.7] RCFL-H*2417(ROCA-070E03) 19,100 [5.6] RCFL-H*2417(ROLA-070E03) 19,100 [5.6] RBHP-17(RCHL-24A2) 19,000 [5.6] RCQD-2417(RGFE-06?MCK?) 19,500 [5.7] RCQD-2417(RGFE-07?MCK?) 19,600 [5.7] RCQD-2417(RGFG-06?MCK?) 19,500 [5.7] RCQD-2417(RGFG-07?MCK?) 19,500 [5.7] RCQD-2417(RGJF-06?MCK?) 19,800 [5.8] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 13,900 [4.1] 13,800 [4.0] 13,650 [4.0] 13,850 [4.1] 13,800 [4.0] 13,900 [4.1] 14,150 [4.1] 13,700 [4.0] 13,850 [4.1] 14,250 [4.2] 13,650 [4.0] 14,250 [4.2] 14,200 [4.2] 14,250 [4.2] 13,650 [4.0] 13,850 [4.1] 14,200 [4.2] 14,200 [4.2] 13,900 [4.1] 13,900 [4.1] 13,900 [4.1] 13,800 [4.0] 13,650 [4.0] 13,850 [4.1] 13,800 [4.0] 13,900 [4.1] 14,150 [4.1] 13,700 [4.0] 14,150 [4.1] 13,700 [4.0] 13,850 [4.1] 14,250 [4.2] 13,650 [4.0] 14,250 [4.2] 14,200 [4.2] 14,250 [4.2] 13,650 [4.0] 13,850 [4.1] 14,200 [4.2] 14,200 [4.2] 13,900 [4.1] 13,900 [4.1] 13,500 [4.0] 14,400 [4.2] 14,550 [4.3] 14,400 [4.2] 14,500 [4.2] 14,800 [4.3] 5,000 [1.5] 5,000 [1.5] 5,250 [1.5] 5,250 [1.5] 5,200 [1.5] 5,200 [1.5] 5,150 [1.5] 5,300 [1.6] 5,250 [1.5] 5,150 [1.5] 5,250 [1.5] 5,150 [1.5] 5,100 [1.5] 5,150 [1.5] 5,250 [1.5] 5,250 [1.5] 5,100 [1.5] 5,100 [1.5] 5,200 [1.5] 5,200 [1.5] 5,000 [1.5] 5,000 [1.5] 5,250 [1.5] 5,250 [1.5] 5,200 [1.5] 5,200 [1.5] 5,150 [1.5] 5,300 [1.6] 5,150 [1.5] 5,300 [1.6] 5,250 [1.5] 5,150 [1.5] 5,250 [1.5] 5,150 [1.5] 5,100 [1.5] 5,150 [1.5] 5,250 [1.5] 5,250 [1.5] 5,100 [1.5] 5,100 [1.5] 5,200 [1.5] 5,200 [1.5] 5,500 [1.6] 5,100 [1.5] 5,050 [1.5] 5,100 [1.5] 5,000 [1.5] 5,000 [1.5] 12.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 14.50 14.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 14.50 14.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 [ ] Designates Metric Conversions 5 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 018JEZ Indoor Coil and/or Air Handler RCQD-2417(RGJF-07?MCK?) RCQD-2417(RGPE-05?BMK?) RCQD-2417(RGPE-07?AMK?) RCQD-2417(RGPT-05?BMK?) RCQD-2417(RGPT-07?AMK?) RCQD-2417(RGRM-04?MAE?) RCQD-2417(RGRM-06?MAE?) RCQD-2417(RGRM-07?MAE?) RCQD-2417(ROCA-070E03) RCQD-2417(ROLA-070E03) RCQD-2417+RXMD-C04 RHKL-HM2417(RCSL-H*2417) RHLL-HM2417(RCSL-H*2417) RHSL-HM1817(RCSL-H*2417) 6 Indoor CFM [L/s] 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 13.00 13.00 12.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 14.50 16.00 16.00 15.00 74 74 74 74 74 74 74 74 74 74 74 74 74 74 575 [271] 575 [271] 625 [295] 650 [307] 625 [295] 575 [271] 600 [283] 625 [295] 600 [283] 600 [283] 650 [307] 650 [307] 650 [307] 600 [283] 12.00 11.50 12.50 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 12.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 14.50 13.50 15.00 14.50 15.50 15.50 15.50 15.50 16.00 15.50 16.00 16.00 15.50 16.00 15.50 15.50 15.50 15.50 15.10 16.00 16.00 16.00 14.50 14.50 15.50 15.50 15.50 15.50 16.00 15.50 16.00 15.50 16.00 16.00 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 800 [378] 800 [378] 800 [378] 800 [378] 800 [378] 825 [389] 800 [378] 800 [378] 825 [389] 800 [378] 800 [378] 850 [401] 800 [378] 725 [342] 850 [401] 850 [401] 800 [378] 825 [389] 850 [401] 825 [389] 800 [378] 800 [378] 800 [378] 800 [378] 800 [378] 825 [389] 800 [378] 800 [378] 825 [389] 800 [378] 825 [389] 800 [378] 800 [378] 850 [401] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 19,500 [5.7] 19,500 [5.7] 19,800 [5.8] 19,800 [5.8] 19,800 [5.8] 19,800 [5.8] 19,900 [5.8] 20,200 [5.9] 19,600 [5.7] 19,600 [5.7] 18,800 [5.5] 19,400 [5.7] 19,400 [5.7] 18,800 [5.5] 14,400 [4.2] 14,400 [4.2] 14,800 [4.3] 14,900 [4.4] 15,100 [4.4] 14,850 [4.4] 15,000 [4.4] 15,400 [4.5] 14,600 [4.3] 14,600 [4.3] 13,800 [4.0] 14,250 [4.2] 14,250 [4.2] 13,650 [4.0] 5,100 [1.5] 5,100 [1.5] 5,000 [1.5] 4,900 [1.4] 4,700 [1.4] 4,950 [1.5] 4,900 [1.4] 4,800 [1.4] 5,000 [1.5] 5,000 [1.5] 5,000 [1.5] 5,150 [1.5] 5,150 [1.5] 5,150 [1.5] 18,450 [5.4] 18,500 [5.4] 18,500 [5.4] 18,300 [5.4] 18,550 [5.4] 18,550 [5.4] 18,800 [5.5] 18,700 [5.5] 18,700 [5.5] 18,500 [5.4] 18,700 [5.5] 19,100 [5.6] 18,500 [5.4] 18,100 [5.3] 18,950 [5.6] 19,100 [5.6] 18,600 [5.4] 18,600 [5.4] 18,950 [5.6] 18,800 [5.5] 18,750 [5.5] 18,750 [5.5] 18,300 [5.4] 18,300 [5.4] 18,550 [5.4] 18,550 [5.4] 18,800 [5.5] 18,700 [5.5] 18,700 [5.5] 18,500 [5.4] 18,700 [5.5] 18,500 [5.4] 18,700 [5.5] 19,100 [5.6] 6,550 [1.9] 5,500 [1.6] 5,500 [1.6] 6,600 [1.9] 6,650 [1.9] 6,650 [1.9] 6,600 [1.9] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,500 [1.9] 6,700 [2.0] 6,900 [2.0] 6,450 [1.9] 6,500 [1.9] 6,600 [1.9] 6,600 [1.9] 6,450 [1.9] 6,600 [1.9] 6,650 [1.9] 6,650 [1.9] 6,600 [1.9] 6,600 [1.9] 6,650 [1.9] 6,650 [1.9] 6,600 [1.9] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,700 [2.0] 6,500 [1.9] 25,000 [7.3] RCFL-H*2417+RXMD-C04 ➀ RHAL-FR24P 24,000 [7.0] RHBL-FR24T 24,000 [7.0] RCFL-A*2414+RXMD-C04 24,800 [7.3] RCFL-A*2417(RGFE-06?MCK?) 25,200 [7.4] RCFL-A*2417(RGFE-07?MCK?) 25,200 [7.4] RCFL-A*2417(RGFG-06?MCK?) 25,400 [7.4] RCFL-A*2417(RGFG-07?MCK?) 25,400 [7.4] RCFL-A*2417(RGGE-06?MCK?) 25,400 [7.4] RCFL-A*2417(RGGE-07?MCK?) 25,200 [7.4] RCFL-A*2417(RGLE-07?AMK?) 25,400 [7.4] RCFL-A*2417(RGLT-07?AMK?) 25,600 [7.5] RCFL-A*2417(RGPE-05?BMK?) 25,200 [7.4] RCFL-A*2417(RGPE-07?AMK?) 25,000 [7.3] RCFL-A*2417(RGPT-05?BMK?) 25,400 [7.4] RCFL-A*2417(RGPT-07?AMK?) 25,600 [7.5] RCFL-A*2417(RGRM-04?MAE?) 25,200 [7.4] 024JEZ RCFL-A*2417(RGRM-06?MAE?) 25,200 [7.4] RCFL-A*2417(RGRM-07?MAE?) 25,400 [7.4] RCFL-A*2417(RHWB-04WMX36A) 25,400 [7.4] RCFL-A*2417(ROCA-070E03) 25,400 [7.4] RCFL-A*2417(ROLA-070E03) 25,400 [7.4] RCFL-A*2417+RXMD-C04 24,800 [7.3] RCFL-H*2414+RXMD-C04 24,800 [7.3] RCFL-H*2417(RGFE-06?MCK?) 25,200 [7.4] RCFL-H*2417(RGFE-07?MCK?) 25,200 [7.4] RCFL-H*2417(RGFG-06?MCK?) 25,400 [7.4] RCFL-H*2417(RGFG-07?MCK?) 25,400 [7.4] RCFL-H*2417(RGGE-06?MCK?) 25,400 [7.4] RCFL-H*2417(RGGE-07?MCK?) 25,200 [7.4] RCFL-H*2417(RGJF-06?MCK?) 25,400 [7.4] RCFL-H*2417(RGJF-07?MCK?) 25,200 [7.4] RCFL-H*2417(RGLE-07?AMK?) 25,400 [7.4] RCFL-H*2417(RGLT-07?AMK?) 25,600 [7.5] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions SEER Sound Rating dB Total Capacity BTU/H [kW] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 024JEZ Indoor Coil and/or Air Handler RCFL-H*2417(RGPE-05?BMK?) RCFL-H*2417(RGPE-07?AMK?) RCFL-H*2417(RGPT-05?BMK?) RCFL-H*2417(RGPT-07?AMK?) RCFL-H*2417(RGRM-04?MAE?) RCFL-H*2417(RGRM-06?MAE?) RCFL-H*2417(RGRM-07?MAE?) RCFL-H*2417(RGTM-06?MAE?) RCFL-H*2417(RHWB-04WMX36A) RCFL-H*2417(ROCA-070E03) RCFL-H*2417(ROLA-070E03) RCFL-H*2621(RGPT-05?BMK?) RCFL-H*2621(RHWB-04WMX36A) RBHP-17(RCHL-24A2) RCQD-2417(RGFE-06?MCK?) RCQD-2417(RGFE-07?MCK?) RCQD-2417(RGFG-06?MCK?) RCQD-2417(RGFG-07?MCK?) RCQD-2417(RGJF-06?MCK?) RCQD-2417(RGJF-07?MCK?) RCQD-2417(RGPE-05?BMK?) RCQD-2417(RGPE-07?AMK?) RCQD-2417(RGPT-05?BMK?) RCQD-2417(RGRM-04?MAE?) RCQD-2417(RGRM-06?MAE?) RCQD-2417(RGRM-07?MAE?) RCQD-2417(RHWB-04WMX36A) RCQD-2417(ROCA-070E03) RCQD-2417(ROLA-070E03) RCQD-2417+RXMD-C04 RHKL-HM2417(RCSL-H*2417) RHLL-HM2417(RCSL-H*2417) RHSL-HM2417(RCSL-H*2417) Total Capacity BTU/H [kW] 25,200 [7.4] 25,000 [7.3] 25,400 [7.4] 25,600 [7.5] 25,200 [7.4] 25,200 [7.4] 25,400 [7.4] 25,200 [7.4] 25,400 [7.4] 25,400 [7.4] 25,400 [7.4] 26,400 [7.7] 26,200 [7.7] 23,200 [6.8] 24,600 [7.2] 24,600 [7.2] 26,000 [7.6] 26,200 [7.7] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] 25,000 [7.3] 25,600 [7.5] 25,600 [7.5] 25,800 [7.6] 26,600 [7.8] 24,600 [7.2] 24,600 [7.2] 24,800 [7.3] 25,600 [7.5] 25,600 [7.5] 25,000 [7.3] 29,000 [8.5] RCFL-H*3617+RXMD-C04 ➀ RCFL-A*3617(RGFE-06?MCK?) 29,200 [8.6] RCFL-A*3617(RGFE-07?MCK?) 29,200 [8.6] RCFL-A*3617(RGFG-06?MCK?) 28,800 [8.4] RCFL-A*3617(RGFG-07?MCK?) 28,800 [8.4] RCFL-A*3617(RGGE-06?MCK?) 29,400 [8.6] RCFL-A*3617(RGGE-07?MCK?) 29,400 [8.6] 030JEZ RCFL-A*3617(RGLE-07?AMK?) 29,400 [8.6] RCFL-A*3617(RGLT-07?AMK?) 29,000 [8.5] RCFL-A*3617(RGPE-05?BMK?) 29,400 [8.6] RCFL-A*3617(RGPE-07?AMK?) 29,400 [8.6] RCFL-A*3617(RGPT-05?BMK?) 28,800 [8.4] RCFL-A*3617(RGPT-07?AMK?) 29,000 [8.5] RCFL-A*3617(RGRM-04?MAE?) 29,200 [8.6] RCFL-A*3617(RGRM-06?MAE?) 28,800 [8.4] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Net Sensible BTU/H [kW] 18,500 [5.4] 18,100 [5.3] 18,950 [5.6] 19,100 [5.6] 18,600 [5.4] 18,600 [5.4] 18,950 [5.6] 18,400 [5.4] 18,800 [5.5] 18,750 [5.5] 18,750 [5.5] 20,300 [5.9] 20,100 [5.9] 16,550 [4.8] 18,600 [5.4] 18,600 [5.4] 19,600 [5.7] 19,800 [5.8] 18,550 [5.4] 18,600 [5.4] 18,600 [5.4] 18,600 [5.4] 19,350 [5.7] 20,050 [5.9] 20,050 [5.9] 20,400 [6.0] 20,600 [6.0] 18,600 [5.4] 18,650 [5.5] 18,750 [5.5] 19,100 [5.6] 18,900 [5.5] 18,450 [5.4] Net Latent BTU/H [kW] 6,700 [2.0] 6,900 [2.0] 6,450 [1.9] 6,500 [1.9] 6,600 [1.9] 6,600 [1.9] 6,450 [1.9] 6,800 [2.0] 6,600 [1.9] 6,650 [1.9] 6,650 [1.9] 6,100 [1.8] 6,100 [1.8] 6,650 [1.9] 6,000 [1.8] 6,000 [1.8] 6,400 [1.9] 6,400 [1.9] 6,050 [1.8] 6,000 [1.8] 6,000 [1.8] 6,000 [1.8] 5,650 [1.7] 5,550 [1.6] 5,550 [1.6] 5,400 [1.6] 6,000 [1.8] 6,000 [1.8] 5,950 [1.7] 6,050 [1.8] 6,500 [1.9] 6,700 [2.0] 6,550 [1.9] EER SEER Sound Rating dB 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 11.50 12.50 12.50 13.00 13.00 12.50 12.50 12.50 12.50 12.50 13.00 13.00 12.50 13.00 12.50 12.50 11.50 13.00 13.00 12.00 15.50 16.00 15.50 15.50 15.50 15.50 15.10 16.00 16.00 16.00 16.00 16.00 16.00 14.00 15.00 15.00 16.00 16.00 15.00 15.00 15.00 15.00 15.00 15.50 15.50 15.00 16.00 15.10 15.10 14.00 16.00 16.00 14.50 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 800 [378] 725 [342] 850 [401] 850 [401] 800 [378] 825 [389] 850 [401] 750 [354] 825 [389] 800 [378] 800 [378] 900 [425] 875 [413] 800 [378] 800 [378] 825 [389] 800 [378] 800 [378] 825 [389] 800 [378] 800 [378] 825 [389] 900 [425] 800 [378] 825 [389] 850 [401] 875 [413] 800 [378] 800 [378] 800 [378] 850 [401] 775 [366] 800 [378] 20,950 [6.1] 21,100 [6.2] 21,150 [6.2] 20,200 [5.9] 20,200 [5.9] 21,300 [6.2] 21,300 [6.2] 21,300 [6.2] 20,350 [6.0] 21,300 [6.2] 21,300 [6.2] 20,100 [5.9] 20,350 [6.0] 21,100 [6.2] 20,000 [5.9] 8,050 [2.4] 8,100 [2.4] 8,050 [2.4] 8,600 [2.5] 8,600 [2.5] 8,100 [2.4] 8,100 [2.4] 8,100 [2.4] 8,650 [2.5] 8,100 [2.4] 8,100 [2.4] 8,700 [2.5] 8,650 [2.5] 8,100 [2.4] 8,800 [2.6] 12.00 13.00 12.50 13.00 13.00 12.50 12.50 13.00 13.00 12.50 12.50 13.00 13.00 12.00 13.00 14.50 15.00 14.50 15.50 15.50 15.10 15.10 15.50 16.00 15.10 15.10 15.50 15.50 14.50 15.50 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 1,000 [472] 1,000 [472] 1,025 [484] 875 [413] 850 [401] 1,025 [484] 1,025 [484] 1,025 [484] 875 [413] 975 [460] 1,000 [472] 850 [401] 875 [413] 1,025 [484] 825 [389] [ ] Designates Metric Conversions 7 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-A*3617(RGRM-07?MAE?) 28,800 [8.4] RCFL-A*3617(RGTM-06?MAE?) 29,000 [8.5] RCFL-A*3617(RHWB-04WMX36A) 29,600 [8.7] RCFL-A*3617(RHWB-06WMX48A) 29,400 [8.6] RCFL-A*3617(ROCA-070E03) 29,600 [8.7] RCFL-A*3617(ROCA-070E04) 29,600 [8.7] RCFL-A*3617(ROLA-070E03) 29,600 [8.7] RCFL-A*3617(ROLA-070E04) 29,600 [8.7] RCFL-A*3617+RXMD-C04 29,000 [8.5] RCFL-A*3621(RGFE-06?MCK?) 29,400 [8.6] RCFL-A*3621(RGFE-07?MCK?) 29,200 [8.6] RCFL-A*3621(RGFE-09?ZCM?) 29,600 [8.7] RCFL-A*3621(RGFE-10?ZCM?) 29,600 [8.7] RCFL-A*3621(RGFG-06?MCK?) 28,800 [8.4] RCFL-A*3621(RGFG-07?MCK?) 29,000 [8.5] RCFL-A*3621(RGFG-09?ZCM?) 29,000 [8.5] RCFL-A*3621(RGFG-10?ZCM?) 29,200 [8.6] RCFL-A*3621(RGGE-06?MCK?) 29,400 [8.6] RCFL-A*3621(RGGE-07?MCK?) 29,400 [8.6] RCFL-A*3621(RGGE-09?ZCM?) 29,600 [8.7] RCFL-A*3621(RGGE-10?ZCM?) 29,600 [8.7] RCFL-A*3621(RGLE-07?AMK?) 29,400 [8.6] RCFL-A*3621(RGLE-07?BRQ?) 29,400 [8.6] RCFL-A*3621(RGLE-10?BRM?) 29,800 [8.7] 030JEZ RCFL-A*3621(RGLT-07?AMK?) 29,200 [8.6] RCFL-A*3621(RGLT-07?BRQ?) 29,800 [8.7] RCFL-A*3621(RGLT-10?BRM?) 29,800 [8.7] RCFL-A*3621(RGPE-05?BMK?) 29,400 [8.6] RCFL-A*3621(RGPE-07?AMK?) 29,400 [8.6] RCFL-A*3621(RGPE-07?BRQ?) 29,600 [8.7] RCFL-A*3621(RGPE-10?BRM?) 30,000 [8.8] RCFL-A*3621(RGPT-05?BMK?) 29,000 [8.5] RCFL-A*3621(RGPT-07?AMK?) 29,000 [8.5] RCFL-A*3621(RGPT-07?BRQ?) 29,800 [8.7] RCFL-A*3621(RGPT-10?BRM?) 29,800 [8.7] RCFL-A*3621(RGRM-04?MAE?) 29,200 [8.6] RCFL-A*3621(RGRM-06?MAE?) 28,800 [8.4] RCFL-A*3621(RGRM-07?MAE?) 28,800 [8.4] RCFL-A*3621(RGRM-07?YBG?) 29,200 [8.6] RCFL-A*3621(RGRM-09?ZAJ?) 29,200 [8.6] RCFL-A*3621(RGRM-10?ZAJ?) 29,400 [8.6] RCFL-A*3621(RGTM-06?MAE?) 29,000 [8.5] RCFL-A*3621(RGTM-07?RBG?) 29,400 [8.6] RCFL-A*3621(RGTM-09?ZAJ?) 29,600 [8.7] RCFL-A*3621(RHWB-04WMX36A) 29,600 [8.7] RCFL-A*3621(RHWB-06WMX48A) 29,600 [8.7] RCFL-A*3621(ROCA-070E03) 29,600 [8.7] RCFL-A*3621(ROCA-070E04) 29,600 [8.7] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 8 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 20,100 [5.9] 20,450 [6.0] 21,600 [6.3] 21,200 [6.2] 21,400 [6.3] 21,400 [6.3] 21,400 [6.3] 21,400 [6.3] 21,000 [6.2] 21,300 [6.2] 21,150 [6.2] 21,450 [6.3] 21,450 [6.3] 20,200 [5.9] 20,200 [5.9] 20,400 [6.0] 20,600 [6.0] 21,300 [6.2] 21,300 [6.2] 21,450 [6.3] 21,450 [6.3] 21,250 [6.2] 20,900 [6.1] 21,800 [6.4] 20,500 [6.0] 21,550 [6.3] 21,550 [6.3] 21,300 [6.2] 21,250 [6.2] 21,450 [6.3] 22,100 [6.5] 20,350 [6.0] 20,500 [6.0] 21,800 [6.4] 21,550 [6.3] 21,100 [6.2] 20,000 [5.9] 20,100 [5.9] 21,100 [6.2] 20,900 [6.1] 21,300 [6.2] 20,450 [6.0] 21,000 [6.2] 21,400 [6.3] 21,600 [6.3] 21,600 [6.3] 21,400 [6.3] 21,400 [6.3] 8,700 [2.5] 8,550 [2.5] 8,000 [2.3] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,000 [2.3] 8,100 [2.4] 8,050 [2.4] 8,150 [2.4] 8,150 [2.4] 8,600 [2.5] 8,800 [2.6] 8,600 [2.5] 8,600 [2.5] 8,100 [2.4] 8,100 [2.4] 8,150 [2.4] 8,150 [2.4] 8,150 [2.4] 8,500 [2.5] 8,000 [2.3] 8,700 [2.5] 8,250 [2.4] 8,250 [2.4] 8,100 [2.4] 8,150 [2.4] 8,150 [2.4] 7,900 [2.3] 8,650 [2.5] 8,500 [2.5] 8,000 [2.3] 8,250 [2.4] 8,100 [2.4] 8,800 [2.6] 8,700 [2.5] 8,100 [2.4] 8,300 [2.4] 8,100 [2.4] 8,550 [2.5] 8,400 [2.5] 8,200 [2.4] 8,000 [2.3] 8,000 [2.3] 8,200 [2.4] 8,200 [2.4] 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 13.00 12.50 12.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 SEER Sound Rating dB Indoor CFM [L/s] 15.10 15.50 15.50 15.50 15.50 15.50 15.50 15.50 14.50 15.10 15.00 15.50 15.50 15.50 15.50 16.00 15.50 15.10 15.10 15.50 15.50 15.50 16.00 16.00 16.00 16.00 16.00 15.10 15.50 16.00 16.00 15.50 15.50 16.00 16.00 14.50 15.50 15.10 14.50 15.50 15.10 15.50 15.50 16.00 15.50 15.50 15.50 15.50 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 850 [401] 900 [425] 1,025 [484] 950 [448] 1,000 [472] 1,000 [472] 975 [460] 1,025 [484] 1,000 [472] 1,000 [472] 1,025 [484] 975 [460] 1,000 [472] 875 [413] 850 [401] 875 [413] 900 [425] 1,025 [484] 1,025 [484] 1,000 [472] 1,000 [472] 1,025 [484] 925 [437] 1,050 [495] 875 [413] 975 [460] 975 [460] 975 [460] 1,000 [472] 1,025 [484] 1,075 [507] 875 [413] 875 [413] 975 [460] 975 [460] 1,025 [484] 825 [389] 850 [401] 975 [460] 950 [448] 1,025 [484] 900 [425] 950 [448] 975 [460] 1,025 [484] 975 [460] 1,000 [472] 1,000 [472] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 900 [425] 900 [425] 900 [425] 1,000 [472] 875 [413] 850 [401] 875 [413] 900 [425] 925 [437] 1,025 [484] 1,025 [484] 900 [425] 925 [437] 1,025 [484] 1,025 [484] 1,075 [507] 1,000 [472] 1,000 [472] 1,000 [472] 975 [460] 1,025 [484] 1,050 [495] 875 [413] 900 [425] 875 [413] 1,025 [484] 1,025 [484] 975 [460] 1,025 [484] 1,025 [484] 975 [460] 1,000 [472] 1,000 [472] 975 [460] 975 [460] 900 [425] 1,000 [472] 1,025 [484] 875 [413] 850 [401] 1,025 [484] 1,025 [484] 1,025 [484] 1,025 [484] 1,025 [484] 875 [413] 975 [460] 1,000 [472] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-A*3621(ROLA-070E03) 29,200 [8.6] RCFL-A*3621(ROLA-070E04) 29,200 [8.6] RCFL-A*3621(ROLA-115E05) 29,200 [8.6] RCFL-A*3621+RXMD-C04 29,000 [8.5] RCFL-A*3821(RGFG-06?MCK?) 29,800 [8.7] RCFL-A*3821(RGFG-07?MCK?) 29,800 [8.7] RCFL-A*3821(RGFG-09?ZCM?) 30,000 [8.8] RCFL-A*3821(RGFG-10?ZCM?) 30,200 [8.8] RCFL-A*3821(RGLT-07?AMK?) 30,000 [8.8] RCFL-A*3821(RGLT-07?BRQ?) 30,600 [9.0] RCFL-A*3821(RGLT-10?BRM?) 30,600 [9.0] RCFL-A*3821(RGPT-05?BMK?) 29,800 [8.7] RCFL-A*3821(RGPT-07?AMK?) 30,000 [8.8] RCFL-A*3821(RGPT-07?BRQ?) 30,600 [9.0] RCFL-A*3821(RGPT-10?BRM?) 30,600 [9.0] RCFL-A*3821(RHWB-04WMX36A) 31,000 [9.1] RCFL-A*3821(RHWB-06WMX48A) 30,600 [9.0] RCFL-A*3821(ROCA-070E03) 30,200 [8.8] RCFL-A*3821(ROCA-070E04) 30,200 [8.8] RCFL-A*3821(ROLA-070E03) 30,200 [8.8] RCFL-A*3821(ROLA-070E04) 30,400 [8.9] RCFL-A*3821(ROLA-115E05) 30,600 [9.0] RCFL-A*3824(RGFG-09?ZCM?) 30,000 [8.8] RCFL-A*3824(RGFG-10?ZCM?) 30,000 [8.8] 030JEZ RCFL-A*3824(RGFG-12?RCM?) 30,000 [8.8] RCFL-A*3824(RGLT-07?BRQ?) 30,600 [9.0] RCFL-A*3824(RGLT-10?BRM?) 30,600 [9.0] RCFL-A*3824(RGLT-12?ARM?) 30,400 [8.9] RCFL-A*3824(RGPT-07?BRQ?) 30,600 [9.0] RCFL-A*3824(RGPT-10?BRM?) 30,600 [9.0] RCFL-A*3824(RGPT-12?ARM?) 30,400 [8.9] RCFL-A*3824(ROCA-070E03) 30,200 [8.8] RCFL-A*3824(ROCA-070E04) 30,200 [8.8] RCFL-A*3824(ROLA-070E03) 30,200 [8.8] RCFL-A*3824(ROLA-070E04) 30,200 [8.8] RCFL-A*3824(ROLA-115E05) 29,800 [8.7] RCFL-H*3617(RGFE-06?MCK?) 29,200 [8.6] RCFL-H*3617(RGFE-07?MCK?) 29,200 [8.6] RCFL-H*3617(RGFG-06?MCK?) 28,800 [8.4] RCFL-H*3617(RGFG-07?MCK?) 28,800 [8.4] RCFL-H*3617(RGGE-06?MCK?) 29,400 [8.6] RCFL-H*3617(RGGE-07?MCK?) 29,400 [8.6] RCFL-H*3617(RGJF-06?MCK?) 29,400 [8.6] RCFL-H*3617(RGJF-07?MCK?) 29,400 [8.6] RCFL-H*3617(RGLE-07?AMK?) 29,400 [8.6] RCFL-H*3617(RGLT-07?AMK?) 29,000 [8.5] RCFL-H*3617(RGPE-05?BMK?) 29,400 [8.6] RCFL-H*3617(RGPE-07?AMK?) 29,400 [8.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 20,600 [6.0] 20,600 [6.0] 20,600 [6.0] 21,000 [6.2] 21,350 [6.3] 21,200 [6.2] 21,500 [6.3] 21,800 [6.4] 21,750 [6.4] 22,700 [6.7] 22,700 [6.7] 21,450 [6.3] 21,750 [6.4] 22,700 [6.7] 22,700 [6.7] 23,400 [6.9] 22,800 [6.7] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 22,550 [6.6] 22,800 [6.7] 21,500 [6.3] 21,600 [6.3] 21,450 [6.3] 22,700 [6.7] 22,700 [6.7] 22,350 [6.5] 22,700 [6.7] 22,700 [6.7] 22,350 [6.5] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 21,450 [6.3] 21,100 [6.2] 21,150 [6.2] 20,200 [5.9] 20,200 [5.9] 21,300 [6.2] 21,300 [6.2] 21,300 [6.2] 21,300 [6.2] 21,300 [6.2] 20,350 [6.0] 21,300 [6.2] 21,300 [6.2] 8,600 [2.5] 8,600 [2.5] 8,600 [2.5] 8,000 [2.3] 8,450 [2.5] 8,600 [2.5] 8,500 [2.5] 8,400 [2.5] 8,250 [2.4] 7,900 [2.3] 7,900 [2.3] 8,350 [2.4] 8,250 [2.4] 7,900 [2.3] 7,900 [2.3] 7,600 [2.2] 7,800 [2.3] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 7,850 [2.3] 7,800 [2.3] 8,500 [2.5] 8,400 [2.5] 8,550 [2.5] 7,900 [2.3] 7,900 [2.3] 8,050 [2.4] 7,900 [2.3] 7,900 [2.3] 8,050 [2.4] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 8,350 [2.4] 8,100 [2.4] 8,050 [2.4] 8,600 [2.5] 8,600 [2.5] 8,100 [2.4] 8,100 [2.4] 8,100 [2.4] 8,100 [2.4] 8,100 [2.4] 8,650 [2.5] 8,100 [2.4] 8,100 [2.4] 13.00 13.00 13.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 13.00 13.00 12.50 12.50 12.50 12.50 13.00 13.00 12.50 12.50 16.00 16.00 16.00 14.50 15.50 16.00 16.00 16.00 16.00 16.00 16.00 15.50 16.00 16.00 16.00 16.00 16.00 15.50 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.50 15.50 16.00 16.00 16.00 15.00 14.50 15.50 15.50 15.10 15.10 15.10 15.10 15.50 16.00 15.10 15.10 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 [ ] Designates Metric Conversions 9 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3617(RGPT-05?BMK?) 28,800 [8.4] RCFL-H*3617(RGPT-07?AMK?) 29,000 [8.5] RCFL-H*3617(RGRM-04?MAE?) 29,200 [8.6] RCFL-H*3617(RGRM-06?MAE?) 28,800 [8.4] RCFL-H*3617(RGRM-07?MAE?) 28,800 [8.4] RCFL-H*3617(RGTM-06?MAE?) 29,000 [8.5] RCFL-H*3617(RHWB-04WMX36A) 29,600 [8.7] RCFL-H*3617(RHWB-06WMX48A) 29,400 [8.6] RCFL-H*3617(ROCA-070E03) 29,600 [8.7] RCFL-H*3617(ROCA-070E04) 29,600 [8.7] RCFL-H*3617(ROLA-070E03) 29,600 [8.7] RCFL-H*3617(ROLA-070E04) 29,600 [8.7] RCFL-H*3621(RGFE-06?MCK?) 29,400 [8.6] RCFL-H*3621(RGFE-07?MCK?) 29,200 [8.6] RCFL-H*3621(RGFE-09?ZCM?) 29,600 [8.7] RCFL-H*3621(RGFE-10?ZCM?) 29,600 [8.7] RCFL-H*3621(RGFG-06?MCK?) 28,800 [8.4] RCFL-H*3621(RGFG-07?MCK?) 29,000 [8.5] RCFL-H*3621(RGFG-09?ZCM?) 29,000 [8.5] RCFL-H*3621(RGFG-10?ZCM?) 29,200 [8.6] RCFL-H*3621(RGGE-06?MCK?) 29,400 [8.6] RCFL-H*3621(RGGE-07?MCK?) 29,400 [8.6] RCFL-H*3621(RGGE-09?ZCM?) 29,600 [8.7] RCFL-H*3621(RGGE-10?ZCM?) 29,600 [8.7] 030JEZ RCFL-H*3621(RGJF-06?MCK?) 29,400 [8.6] RCFL-H*3621(RGJF-07?MCK?) 29,400 [8.6] RCFL-H*3621(RGJF-09?ZCM?) 29,600 [8.7] RCFL-H*3621(RGJF-10?ZCM?) 29,600 [8.7] RCFL-H*3621(RGLE-07?AMK?) 29,400 [8.6] RCFL-H*3621(RGLE-07?BRQ?) 29,400 [8.6] RCFL-H*3621(RGLE-10?BRM?) 29,800 [8.7] RCFL-H*3621(RGLT-07?AMK?) 29,200 [8.6] RCFL-H*3621(RGLT-07?BRQ?) 29,800 [8.7] RCFL-H*3621(RGLT-10?BRM?) 29,800 [8.7] RCFL-H*3621(RGPE-05?BMK?) 29,400 [8.6] RCFL-H*3621(RGPE-07?AMK?) 29,400 [8.6] RCFL-H*3621(RGPE-07?BRQ?) 29,600 [8.7] RCFL-H*3621(RGPE-10?BRM?) 30,000 [8.8] RCFL-H*3621(RGPT-05?BMK?) 29,000 [8.5] RCFL-H*3621(RGPT-07?AMK?) 29,000 [8.5] RCFL-H*3621(RGPT-07?BRQ?) 29,800 [8.7] RCFL-H*3621(RGPT-10?BRM?) 29,800 [8.7] RCFL-H*3621(RGRM-04?MAE?) 29,200 [8.6] RCFL-H*3621(RGRM-06?MAE?) 28,800 [8.4] RCFL-H*3621(RGRM-07?MAE?) 28,800 [8.4] RCFL-H*3621(RGRM-07?YBG?) 29,200 [8.6] RCFL-H*3621(RGRM-09?ZAJ?) 29,200 [8.6] RCFL-H*3621(RGRM-10?ZAJ?) 29,400 [8.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 10 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 20,100 [5.9] 20,350 [6.0] 21,100 [6.2] 20,000 [5.9] 20,100 [5.9] 20,450 [6.0] 21,600 [6.3] 21,200 [6.2] 21,400 [6.3] 21,400 [6.3] 21,400 [6.3] 21,400 [6.3] 21,300 [6.2] 21,150 [6.2] 21,450 [6.3] 21,450 [6.3] 20,200 [5.9] 20,200 [5.9] 20,400 [6.0] 20,600 [6.0] 21,300 [6.2] 21,300 [6.2] 21,450 [6.3] 21,450 [6.3] 21,300 [6.2] 21,300 [6.2] 21,450 [6.3] 21,450 [6.3] 21,250 [6.2] 20,900 [6.1] 21,800 [6.4] 20,500 [6.0] 21,550 [6.3] 21,550 [6.3] 21,300 [6.2] 21,250 [6.2] 21,450 [6.3] 22,100 [6.5] 20,350 [6.0] 20,500 [6.0] 21,800 [6.4] 21,550 [6.3] 21,100 [6.2] 20,000 [5.9] 20,100 [5.9] 21,100 [6.2] 20,900 [6.1] 21,300 [6.2] 8,700 [2.5] 8,650 [2.5] 8,100 [2.4] 8,800 [2.6] 8,700 [2.5] 8,550 [2.5] 8,000 [2.3] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,200 [2.4] 8,100 [2.4] 8,050 [2.4] 8,150 [2.4] 8,150 [2.4] 8,600 [2.5] 8,800 [2.6] 8,600 [2.5] 8,600 [2.5] 8,100 [2.4] 8,100 [2.4] 8,150 [2.4] 8,150 [2.4] 8,100 [2.4] 8,100 [2.4] 8,150 [2.4] 8,150 [2.4] 8,150 [2.4] 8,500 [2.5] 8,000 [2.3] 8,700 [2.5] 8,250 [2.4] 8,250 [2.4] 8,100 [2.4] 8,150 [2.4] 8,150 [2.4] 7,900 [2.3] 8,650 [2.5] 8,500 [2.5] 8,000 [2.3] 8,250 [2.4] 8,100 [2.4] 8,800 [2.6] 8,700 [2.5] 8,100 [2.4] 8,300 [2.4] 8,100 [2.4] 13.00 13.00 12.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 13.00 13.00 12.50 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 13.00 12.50 12.00 13.00 12.50 SEER Sound Rating dB Indoor CFM [L/s] 15.50 15.50 14.50 15.50 15.10 15.50 15.50 15.50 15.50 15.50 15.50 15.50 15.10 15.00 15.50 15.50 15.50 15.50 16.00 15.50 15.10 15.10 15.50 15.50 15.10 15.10 15.50 15.50 15.50 16.00 16.00 16.00 16.00 16.00 15.10 15.50 16.00 16.00 15.50 15.50 16.00 16.00 14.50 15.50 15.10 14.50 15.50 15.10 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 850 [401] 875 [413] 1,025 [484] 825 [389] 850 [401] 900 [425] 1,025 [484] 950 [448] 1,000 [472] 1,000 [472] 975 [460] 1,025 [484] 1,000 [472] 1,025 [484] 975 [460] 1,000 [472] 875 [413] 850 [401] 875 [413] 900 [425] 1,025 [484] 1,025 [484] 1,000 [472] 1,000 [472] 1,025 [484] 1,025 [484] 1,000 [472] 1,000 [472] 1,025 [484] 925 [437] 1,050 [495] 875 [413] 975 [460] 975 [460] 975 [460] 1,000 [472] 1,025 [484] 1,075 [507] 875 [413] 875 [413] 975 [460] 975 [460] 1,025 [484] 825 [389] 850 [401] 975 [460] 950 [448] 1,025 [484] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 900 [425] 950 [448] 975 [460] 1,025 [484] 975 [460] 1,000 [472] 1,000 [472] 900 [425] 900 [425] 900 [425] 1,000 [472] 1,000 [472] 1,025 [484] 975 [460] 1,000 [472] 875 [413] 850 [401] 875 [413] 900 [425] 1,025 [484] 1,025 [484] 1,000 [472] 1,000 [472] 1,025 [484] 1,025 [484] 1,025 [484] 1,000 [472] 1,025 [484] 1,025 [484] 1,050 [495] 925 [437] 1,025 [484] 1,025 [484] 975 [460] 900 [425] 1,025 [484] 900 [425] 900 [425] 925 [437] 1,025 [484] 1,025 [484] 925 [437] 1,000 [472] 950 [448] 975 [460] 950 [448] 1,025 [484] 900 [425] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3621(RGTM-06?MAE?) 29,000 [8.5] RCFL-H*3621(RGTM-07?RBG?) 29,400 [8.6] RCFL-H*3621(RGTM-09?ZAJ?) 29,600 [8.7] RCFL-H*3621(RHWB-04WMX36A) 29,600 [8.7] RCFL-H*3621(RHWB-06WMX48A) 29,600 [8.7] RCFL-H*3621(ROCA-070E03) 29,600 [8.7] RCFL-H*3621(ROCA-070E04) 29,600 [8.7] RCFL-H*3621(ROLA-070E03) 29,200 [8.6] RCFL-H*3621(ROLA-070E04) 29,200 [8.6] RCFL-H*3621(ROLA-115E05) 29,200 [8.6] RCFL-H*3621+RXMD-C04 29,000 [8.5] RCFL-H*3821(RGFE-06?MCK?) 30,000 [8.8] RCFL-H*3821(RGFE-07?MCK?) 30,200 [8.8] RCFL-H*3821(RGFE-09?ZCM?) 30,200 [8.8] RCFL-H*3821(RGFE-10?ZCM?) 30,200 [8.8] RCFL-H*3821(RGFG-06?MCK?) 29,800 [8.7] RCFL-H*3821(RGFG-07?MCK?) 29,800 [8.7] RCFL-H*3821(RGFG-09?ZCM?) 30,000 [8.8] RCFL-H*3821(RGFG-10?ZCM?) 30,200 [8.8] RCFL-H*3821(RGGE-06?MCK?) 30,200 [8.8] RCFL-H*3821(RGGE-07?MCK?) 30,200 [8.8] RCFL-H*3821(RGGE-09?ZCM?) 30,200 [8.8] RCFL-H*3821(RGGE-10?ZCM?) 30,200 [8.8] RCFL-H*3821(RGJF-06?MCK?) 30,200 [8.8] 030JEZ RCFL-H*3821(RGJF-07?MCK?) 30,200 [8.8] RCFL-H*3821(RGJF-09?ZCM?) 30,400 [8.9] RCFL-H*3821(RGJF-10?ZCM?) 30,200 [8.8] RCFL-H*3821(RGLE-07?AMK?) 30,400 [8.9] RCFL-H*3821(RGLE-07?BRQ?) 30,400 [8.9] RCFL-H*3821(RGLE-10?BRM?) 30,600 [9.0] RCFL-H*3821(RGLT-07?AMK?) 30,000 [8.8] RCFL-H*3821(RGLT-07?BRQ?) 30,600 [9.0] RCFL-H*3821(RGLT-10?BRM?) 30,600 [9.0] RCFL-H*3821(RGPE-05?BMK?) 30,200 [8.8] RCFL-H*3821(RGPE-07?AMK?) 29,800 [8.7] RCFL-H*3821(RGPE-07?BRQ?) 30,400 [8.9] RCFL-H*3821(RGPE-10?BRM?) 30,000 [8.8] RCFL-H*3821(RGPT-05?BMK?) 29,800 [8.7] RCFL-H*3821(RGPT-07?AMK?) 30,000 [8.8] RCFL-H*3821(RGPT-07?BRQ?) 30,600 [9.0] RCFL-H*3821(RGPT-10?BRM?) 30,600 [9.0] RCFL-H*3821(RGRM-04?MAE?) 29,800 [8.7] RCFL-H*3821(RGRM-06?MAE?) 30,000 [8.8] RCFL-H*3821(RGRM-07?MAE?) 29,600 [8.7] RCFL-H*3821(RGRM-07?YBG?) 30,000 [8.8] RCFL-H*3821(RGRM-09?ZAJ?) 30,000 [8.8] RCFL-H*3821(RGRM-10?ZAJ?) 30,200 [8.8] RCFL-H*3821(RGTM-06?MAE?) 29,800 [8.7] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 20,450 [6.0] 21,000 [6.2] 21,400 [6.3] 21,600 [6.3] 21,600 [6.3] 21,400 [6.3] 21,400 [6.3] 20,600 [6.0] 20,600 [6.0] 20,600 [6.0] 21,000 [6.2] 22,050 [6.5] 22,400 [6.6] 22,200 [6.5] 22,200 [6.5] 21,350 [6.3] 21,200 [6.2] 21,500 [6.3] 21,800 [6.4] 22,350 [6.5] 22,350 [6.5] 22,200 [6.5] 22,200 [6.5] 22,350 [6.5] 22,350 [6.5] 22,550 [6.6] 22,200 [6.5] 22,550 [6.6] 22,500 [6.6] 22,800 [6.7] 21,750 [6.4] 22,700 [6.7] 22,700 [6.7] 22,250 [6.5] 21,450 [6.3] 22,500 [6.6] 21,600 [6.3] 21,450 [6.3] 21,750 [6.4] 22,700 [6.7] 22,700 [6.7] 21,600 [6.3] 22,100 [6.5] 21,550 [6.3] 22,100 [6.5] 21,850 [6.4] 22,350 [6.5] 21,450 [6.3] 8,550 [2.5] 8,400 [2.5] 8,200 [2.4] 8,000 [2.3] 8,000 [2.3] 8,200 [2.4] 8,200 [2.4] 8,600 [2.5] 8,600 [2.5] 8,600 [2.5] 8,000 [2.3] 7,950 [2.3] 7,800 [2.3] 8,000 [2.3] 8,000 [2.3] 8,450 [2.5] 8,600 [2.5] 8,500 [2.5] 8,400 [2.5] 7,850 [2.3] 7,850 [2.3] 8,000 [2.3] 8,000 [2.3] 7,850 [2.3] 7,850 [2.3] 7,850 [2.3] 8,000 [2.3] 7,850 [2.3] 7,900 [2.3] 7,800 [2.3] 8,250 [2.4] 7,900 [2.3] 7,900 [2.3] 7,950 [2.3] 8,350 [2.4] 7,900 [2.3] 8,400 [2.5] 8,350 [2.4] 8,250 [2.4] 7,900 [2.3] 7,900 [2.3] 8,200 [2.4] 7,900 [2.3] 8,050 [2.4] 7,900 [2.3] 8,150 [2.4] 7,850 [2.3] 8,350 [2.4] 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 12.50 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 13.00 13.00 13.00 13.00 13.00 15.50 15.50 16.00 15.50 15.50 15.50 15.50 16.00 16.00 16.00 14.50 15.10 15.10 16.00 16.00 15.50 16.00 16.00 16.00 15.10 15.50 16.00 16.00 15.50 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.50 16.00 16.00 16.00 15.50 16.00 16.00 16.00 15.10 15.10 15.00 15.00 15.50 15.50 16.00 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 [ ] Designates Metric Conversions 11 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3821(RGTM-07?RBG?) 30,000 [8.8] RCFL-H*3821(RGTM-09?ZAJ?) 30,400 [8.9] RCFL-H*3821(ROCA-070E03) 30,200 [8.8] RCFL-H*3821(ROCA-070E04) 30,200 [8.8] RCFL-H*3821(ROLA-070E03) 30,200 [8.8] RCFL-H*3821(ROLA-070E04) 30,400 [8.9] RCFL-H*3821(ROLA-115E05) 30,600 [9.0] RCFL-H*3821+RXMD-C04 29,800 [8.7] RCFL-H*3824(RGFE-09?ZCM?) 30,400 [8.9] RCFL-H*3824(RGFE-10?ZCM?) 29,800 [8.7] RCFL-H*3824(RGFE-12?RCM?) 30,400 [8.9] RCFL-H*3824(RGFG-09?ZCM?) 30,000 [8.8] RCFL-H*3824(RGFG-10?ZCM?) 30,000 [8.8] RCFL-H*3824(RGFG-12?RCM?) 30,000 [8.8] RCFL-H*3824(RGGE-09?ZCM?) 30,200 [8.8] RCFL-H*3824(RGGE-10?ZCM?) 30,200 [8.8] RCFL-H*3824(RGGE-12?RCM?) 30,600 [9.0] RCFL-H*3824(RGJF-09?ZCM?) 30,400 [8.9] RCFL-H*3824(RGJF-10?ZCM?) 30,400 [8.9] RCFL-H*3824(RGJF-12?RCM?) 30,600 [9.0] RCFL-H*3824(RGLE-07?BRQ?) 30,000 [8.8] RCFL-H*3824(RGLE-10?BRM?) 29,800 [8.7] RCFL-H*3824(RGLE-12?ARM?) 30,200 [8.8] RCFL-H*3824(RGLT-07?BRQ?) 30,600 [9.0] 030JEZ RCFL-H*3824(RGLT-10?BRM?) 30,600 [9.0] RCFL-H*3824(RGLT-12?ARM?) 30,400 [8.9] RCFL-H*3824(RGPE-07?BRQ?) 30,000 [8.8] RCFL-H*3824(RGPE-10?BRM?) 30,800 [9.0] RCFL-H*3824(RGPE-12?ARM?) 30,800 [9.0] RCFL-H*3824(RGPT-07?BRQ?) 30,600 [9.0] RCFL-H*3824(RGPT-10?BRM?) 30,600 [9.0] RCFL-H*3824(RGPT-12?ARM?) 30,400 [8.9] RCFL-H*3824(RGRM-07?YBG?) 29,400 [8.6] RCFL-H*3824(RGRM-09?ZAJ?) 30,400 [8.9] RCFL-H*3824(RGRM-10?ZAJ?) 30,200 [8.8] RCFL-H*3824(RGRM-12?RAJ?) 30,000 [8.8] RCFL-H*3824(RGTM-07?RBG?) 30,000 [8.8] RCFL-H*3824(RGTM-09?ZAJ?) 30,800 [9.0] RCFL-H*3824(ROCA-070E03) 30,200 [8.8] RCFL-H*3824(ROCA-070E04) 30,200 [8.8] RCFL-H*3824(ROLA-070E03) 30,200 [8.8] RCFL-H*3824(ROLA-070E04) 30,200 [8.8] RCFL-H*3824(ROLA-115E05) 29,800 [8.7] RCFL-H*3824+RXMD-C04 29,800 [8.7] RBHP-21(RCHL-36A1) 28,000 [8.2] RCQD-3621(RGFE-06?MCK?) 29,800 [8.7] RCQD-3621(RGFE-07?MCK?) 29,800 [8.7] RCQD-3621(RGFE-09?ZCM?) 30,000 [8.8] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 21,850 [6.4] 22,400 [6.6] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 22,550 [6.6] 22,800 [6.7] 21,950 [6.4] 22,550 [6.6] 21,450 [6.3] 22,400 [6.6] 21,500 [6.3] 21,600 [6.3] 21,450 [6.3] 22,200 [6.5] 22,200 [6.5] 22,800 [6.7] 22,550 [6.6] 22,650 [6.6] 22,800 [6.7] 21,700 [6.4] 21,350 [6.3] 21,900 [6.4] 22,700 [6.7] 22,700 [6.7] 22,350 [6.5] 21,650 [6.3] 23,100 [6.8] 23,100 [6.8] 22,700 [6.7] 22,700 [6.7] 22,350 [6.5] 20,950 [6.1] 22,750 [6.7] 22,350 [6.5] 21,750 [6.4] 21,850 [6.4] 23,250 [6.8] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 22,200 [6.5] 21,450 [6.3] 21,950 [6.4] 19,450 [5.7] 22,200 [6.5] 22,200 [6.5] 22,350 [6.5] 8,150 [2.4] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 7,850 [2.3] 7,800 [2.3] 7,850 [2.3] 7,850 [2.3] 8,350 [2.4] 8,000 [2.3] 8,500 [2.5] 8,400 [2.5] 8,550 [2.5] 8,000 [2.3] 8,000 [2.3] 7,800 [2.3] 7,850 [2.3] 7,750 [2.3] 7,800 [2.3] 8,300 [2.4] 8,450 [2.5] 8,300 [2.4] 7,900 [2.3] 7,900 [2.3] 8,050 [2.4] 8,350 [2.4] 7,700 [2.3] 7,700 [2.3] 7,900 [2.3] 7,900 [2.3] 8,050 [2.4] 8,450 [2.5] 7,650 [2.2] 7,850 [2.3] 8,250 [2.4] 8,150 [2.4] 7,550 [2.2] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 8,000 [2.3] 8,350 [2.4] 7,850 [2.3] 8,550 [2.5] 7,600 [2.2] 7,600 [2.2] 7,650 [2.2] 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 13.00 13.00 13.00 SEER Sound Rating dB Indoor CFM [L/s] 16.00 16.00 15.50 15.50 16.00 16.00 16.00 14.50 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.10 15.50 15.50 16.00 16.00 16.00 15.50 15.50 16.00 16.00 16.00 14.50 15.00 15.00 15.00 15.50 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 950 [448] 975 [460] 1,000 [472] 1,000 [472] 975 [460] 1,025 [484] 1,050 [495] 995 [470] 1,025 [484] 900 [425] 975 [460] 875 [413] 900 [425] 875 [413] 1,000 [472] 1,000 [472] 1,050 [495] 1,025 [484] 1,050 [495] 1,050 [495] 925 [437] 875 [413] 925 [437] 1,025 [484] 1,025 [484] 975 [460] 900 [425] 1,075 [507] 1,075 [507] 1,025 [484] 1,025 [484] 975 [460] 850 [401] 1,075 [507] 1,025 [484] 925 [437] 950 [448] 1,100 [519] 1,000 [472] 1,000 [472] 975 [460] 975 [460] 900 [425] 995 [470] 1,000 [472] 1,000 [472] 1,025 [484] 1,025 [484] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,000 [472] 875 [413] 850 [401] 875 [413] 900 [425] 1,025 [484] 1,025 [484] 1,000 [472] 1,000 [472] 975 [460] 1,000 [472] 1,025 [484] 900 [425] 900 [425] 925 [437] 1,050 [495] 1,050 [495] 1,025 [484] 1,000 [472] 1,025 [484] 975 [460] 950 [448] 1,025 [484] 1,075 [507] 1,000 [472] 1,000 [472] 1,000 [472] 975 [460] 975 [460] 1,050 [495] 1,000 [472] 875 [413] 900 [425] 875 [413] 1,050 [495] 1,050 [495] 1,075 [507] 975 [460] 975 [460] 1,000 [472] 1,000 [472] 975 [460] 975 [460] 900 [425] 1,000 [472] 1,025 [484] 1,000 [472] 950 [448] 1,000 [472] 975 [460] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 030JEZ Indoor Coil and/or Air Handler RCQD-3621(RGFE-10?ZCM?) RCQD-3621(RGFG-06?MCK?) RCQD-3621(RGFG-07?MCK?) RCQD-3621(RGFG-09?ZCM?) RCQD-3621(RGFG-10?ZCM?) RCQD-3621(RGJF-06?MCK?) RCQD-3621(RGJF-07?MCK?) RCQD-3621(RGJF-09?ZCM?) RCQD-3621(RGJF-10?ZCM?) RCQD-3621(RGPE-05?BMK?) RCQD-3621(RGPE-07?AMK?) RCQD-3621(RGPE-07?BRQ?) RCQD-3621(RGPE-10?BRM?) RCQD-3621(RGPT-05?BMK?) RCQD-3621(RGPT-07?AMK?) RCQD-3621(RGPT-07?BRQ?) RCQD-3621(RGPT-10?BRM?) RCQD-3621(RGRM-04?MAE?) RCQD-3621(RGRM-06?MAE?) RCQD-3621(RGRM-07?MAE?) RCQD-3621(RGRM-07?YBG?) RCQD-3621(RGRM-09?ZAJ?) RCQD-3621(RGRM-10?ZAJ?) RCQD-3621(RHWB-04WMX36A) RCQD-3621(RHWB-06WMX48A) RCQD-3621(ROCA-070E03) RCQD-3621(ROCA-070E04) RCQD-3621(ROLA-070E03) RCQD-3621(ROLA-070E04) RCQD-3621(ROLA-115E05) RCQD-3621+RXMD-C04 RCQD-3624(RGFG-09?ZCM?) RCQD-3624(RGFG-10?ZCM?) RCQD-3624(RGFG-12?RCM?) RCQD-3624(RGPE-07?BRQ?) RCQD-3624(RGPT-07?BRQ?) RCQD-3624(RGPT-10?BRM?) RCQD-3624(RGPT-12?ARM?) RCQD-3624(RGRM-07?YBG?) RCQD-3624(ROCA-070E03) RCQD-3624(ROCA-070E04) RCQD-3624(ROLA-070E03) RCQD-3624(ROLA-070E04) RCQD-3624(ROLA-115E05) RCQD-3624+RXMD-C04 RHKL-HM3617(RCSL-H*3617) RHLL-HM3617(RCSL-H*3617) RHSL-HM3017(RCSL-H*3617) RHKL-HM3821(RCSL-H*3821) RHLL-HM3821(RCSL-H*3821) Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 30,200 [8.8] 29,800 [8.7] 29,600 [8.7] 29,800 [8.7] 30,000 [8.8] 30,000 [8.8] 30,000 [8.8] 30,200 [8.8] 30,200 [8.8] 30,000 [8.8] 30,000 [8.8] 30,200 [8.8] 29,800 [8.7] 29,600 [8.7] 29,800 [8.7] 30,400 [8.9] 30,400 [8.9] 30,600 [9.0] 30,600 [9.0] 30,400 [8.9] 30,600 [9.0] 29,800 [8.7] 30,000 [8.8] 30,800 [9.0] 30,400 [8.9] 30,000 [8.8] 30,000 [8.8] 30,200 [8.8] 30,200 [8.8] 30,400 [8.9] 29,600 [8.7] 29,800 [8.7] 30,000 [8.8] 30,000 [8.8] 30,400 [8.9] 30,600 [9.0] 30,600 [9.0] 30,400 [8.9] 30,600 [9.0] 30,200 [8.8] 30,200 [8.8] 30,200 [8.8] 30,200 [8.8] 29,800 [8.7] 29,600 [8.7] 29,600 [8.7] 29,800 [8.7] 29,000 [8.5] 30,400 [8.9] 30,400 [8.9] 22,550 [6.6] 21,600 [6.3] 21,300 [6.2] 21,550 [6.3] 21,850 [6.4] 22,350 [6.5] 22,400 [6.6] 22,550 [6.6] 22,550 [6.6] 22,350 [6.5] 22,350 [6.5] 22,500 [6.6] 21,750 [6.4] 21,550 [6.3] 21,800 [6.4] 22,850 [6.7] 22,850 [6.7] 23,650 [6.9] 23,650 [6.9] 23,500 [6.9] 23,650 [6.9] 21,950 [6.4] 22,400 [6.6] 23,500 [6.9] 22,800 [6.7] 22,300 [6.5] 22,300 [6.5] 22,450 [6.6] 22,450 [6.6] 22,900 [6.7] 22,000 [6.4] 21,550 [6.3] 21,850 [6.4] 21,750 [6.4] 22,850 [6.7] 23,050 [6.8] 23,150 [6.8] 22,650 [6.6] 23,700 [6.9] 22,500 [6.6] 22,500 [6.6] 22,450 [6.6] 22,450 [6.6] 21,700 [6.4] 22,000 [6.4] 21,350 [6.3] 21,550 [6.3] 20,700 [6.1] 22,350 [6.5] 22,400 [6.6] 7,650 [2.2] 8,200 [2.4] 8,300 [2.4] 8,250 [2.4] 8,150 [2.4] 7,650 [2.2] 7,600 [2.2] 7,650 [2.2] 7,650 [2.2] 7,650 [2.2] 7,650 [2.2] 7,700 [2.3] 8,050 [2.4] 8,050 [2.4] 8,000 [2.3] 7,550 [2.2] 7,550 [2.2] 6,950 [2.0] 6,950 [2.0] 6,900 [2.0] 6,950 [2.0] 7,850 [2.3] 7,600 [2.2] 7,300 [2.1] 7,600 [2.2] 7,700 [2.3] 7,700 [2.3] 7,750 [2.3] 7,750 [2.3] 7,500 [2.2] 7,600 [2.2] 8,250 [2.4] 8,150 [2.4] 8,250 [2.4] 7,550 [2.2] 7,550 [2.2] 7,450 [2.2] 7,750 [2.3] 6,900 [2.0] 7,700 [2.3] 7,700 [2.3] 7,750 [2.3] 7,750 [2.3] 8,100 [2.4] 7,600 [2.2] 8,250 [2.4] 8,250 [2.4] 8,300 [2.4] 8,050 [2.4] 8,000 [2.3] 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 11.50 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 11.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 11.50 13.00 13.00 12.00 13.00 13.00 15.50 15.50 15.50 16.00 16.00 15.00 15.00 15.50 15.50 15.00 15.50 16.00 16.00 15.50 15.50 16.00 16.00 14.50 15.00 14.00 14.50 15.50 15.00 15.50 16.00 15.50 15.50 15.50 15.50 15.50 14.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.00 15.50 15.50 16.00 16.00 16.00 14.00 16.00 16.00 14.50 16.00 16.00 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 13 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] 35,400 [10.4] RCFL-H*3617+RXMD-C04 ➀ RCFL-A*3617(RGFE-06?MCK?) 35,200 [10.3] RCFL-A*3617(RGFE-07?MCK?) 35,400 [10.4] RCFL-A*3617(RGFG-06?MCK?) 35,200 [10.3] RCFL-A*3617(RGFG-07?MCK?) 35,400 [10.4] RCFL-A*3617(RGGE-06?MCK?) 35,600 [10.4] RCFL-A*3617(RGGE-07?MCK?) 35,600 [10.4] RCFL-A*3617(RGLE-07?AMK?) 35,800 [10.5] RCFL-A*3617(RGLT-07?AMK?) 35,600 [10.4] RCFL-A*3617(RGPE-07?AMK?) 35,400 [10.4] RCFL-A*3617(RGPT-05?BMK?) 35,400 [10.4] RCFL-A*3617(RGPT-07?AMK?) 35,600 [10.4] RCFL-A*3617(RGRM-04?MAE?) 35,600 [10.4] RCFL-A*3617(RGRM-06?MAE?) 35,400 [10.4] RCFL-A*3617(RHWB-04WMX36A) 35,800 [10.5] RCFL-A*3617(RHWB-06WMX48A) 36,200 [10.6] RCFL-A*3617(ROCA-070E03) 36,200 [10.6] RCFL-A*3617(ROCA-070E04) 36,200 [10.6] RCFL-A*3617(ROLA-070E03) 36,200 [10.6] RCFL-A*3617(ROLA-070E04) 35,800 [10.5] RCFL-A*3617+RXMD-C04 35,400 [10.4] RCFL-A*3621(RGFE-06?MCK?) 35,200 [10.3] RCFL-A*3621(RGFE-07?MCK?) 35,600 [10.4] RCFL-A*3621(RGFE-09?ZCM?) 35,800 [10.5] 036JEZ RCFL-A*3621(RGFE-10?ZCM?) 35,600 [10.4] RCFL-A*3621(RGFG-06?MCK?) 35,200 [10.3] RCFL-A*3621(RGFG-07?MCK?) 35,400 [10.4] RCFL-A*3621(RGFG-09?ZCM?) 35,600 [10.4] RCFL-A*3621(RGFG-10?ZCM?) 35,800 [10.5] RCFL-A*3621(RGGE-06?MCK?) 35,600 [10.4] RCFL-A*3621(RGGE-07?MCK?) 35,600 [10.4] RCFL-A*3621(RGGE-09?ZCM?) 35,800 [10.5] RCFL-A*3621(RGGE-10?ZCM?) 35,600 [10.4] RCFL-A*3621(RGLE-07?AMK?) 35,800 [10.5] RCFL-A*3621(RGLE-10?BRM?) 35,800 [10.5] RCFL-A*3621(RGLT-07?AMK?) 35,600 [10.4] RCFL-A*3621(RGLT-07?BRQ?) 36,400 [10.7] RCFL-A*3621(RGLT-10?BRM?) 36,400 [10.7] RCFL-A*3621(RGPE-07?AMK?) 35,400 [10.4] RCFL-A*3621(RGPE-07?BRQ?) 35,800 [10.5] RCFL-A*3621(RGPE-10?BRM?) 35,800 [10.5] RCFL-A*3621(RGPT-05?BMK?) 35,600 [10.4] RCFL-A*3621(RGPT-07?AMK?) 35,600 [10.4] RCFL-A*3621(RGPT-07?BRQ?) 36,000 [10.5] RCFL-A*3621(RGPT-10?BRM?) 36,400 [10.7] RCFL-A*3621(RGRM-04?MAE?) 35,600 [10.4] RCFL-A*3621(RGRM-06?MAE?) 35,400 [10.4] RCFL-A*3621(RGRM-09?ZAJ?) 35,600 [10.4] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 14 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 23,800 [7.0] 23,350 [6.8] 23,750 [7.0] 23,400 [6.9] 23,800 [7.0] 23,900 [7.0] 23,900 [7.0] 24,100 [7.1] 23,900 [7.0] 23,400 [6.9] 23,750 [7.0] 23,900 [7.0] 23,950 [7.0] 23,500 [6.9] 24,200 [7.1] 25,000 [7.3] 25,250 [7.4] 25,250 [7.4] 25,050 [7.3] 24,100 [7.1] 23,800 [7.0] 23,350 [6.8] 23,950 [7.0] 24,100 [7.1] 23,900 [7.0] 23,400 [6.9] 23,800 [7.0] 24,000 [7.0] 24,000 [7.0] 23,900 [7.0] 23,900 [7.0] 24,050 [7.0] 23,900 [7.0] 24,050 [7.0] 24,000 [7.0] 23,900 [7.0] 25,350 [7.4] 25,200 [7.4] 23,400 [6.9] 24,050 [7.0] 24,050 [7.0] 23,950 [7.0] 23,900 [7.0] 24,200 [7.1] 25,200 [7.4] 23,950 [7.0] 23,500 [6.9] 23,950 [7.0] 11,600 [3.4] 11,850 [3.5] 11,650 [3.4] 11,800 [3.5] 11,600 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 12,000 [3.5] 11,650 [3.4] 11,700 [3.4] 11,650 [3.4] 11,900 [3.5] 11,600 [3.4] 11,200 [3.3] 10,950 [3.2] 10,950 [3.2] 11,150 [3.3] 11,700 [3.4] 11,600 [3.4] 11,850 [3.5] 11,650 [3.4] 11,700 [3.4] 11,700 [3.4] 11,800 [3.5] 11,600 [3.4] 11,600 [3.4] 11,800 [3.5] 11,700 [3.4] 11,700 [3.4] 11,750 [3.4] 11,700 [3.4] 11,750 [3.4] 11,800 [3.5] 11,700 [3.4] 11,050 [3.2] 11,200 [3.3] 12,000 [3.5] 11,750 [3.4] 11,750 [3.4] 11,650 [3.4] 11,700 [3.4] 11,800 [3.5] 11,200 [3.3] 11,650 [3.4] 11,900 [3.5] 11,650 [3.4] 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.00 12.50 12.00 12.00 12.50 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 13.00 12.50 12.50 12.50 12.50 13.00 13.00 12.00 12.50 13.00 12.50 12.00 12.00 12.50 SEER Sound Rating dB Indoor CFM [L/s] 14.50 14.50 14.50 14.50 14.50 15.10 15.10 15.10 15.10 15.10 14.50 15.00 14.50 14.50 15.10 14.50 14.50 14.50 15.00 15.10 14.50 14.50 14.50 15.10 15.10 15.00 15.00 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.50 15.10 15.10 15.10 15.10 15.50 15.50 14.50 15.10 15.50 15.10 14.50 14.50 15.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,050 [495] 1,000 [472] 1,025 [484] 1,000 [472] 1,050 [495] 1,025 [484] 1,025 [484] 1,025 [484] 1,050 [495] 1,000 [472] 1,050 [495] 1,050 [495] 1,025 [484] 1,000 [472] 1,025 [484] 1,150 [543] 1,200 [566] 1,200 [566] 1,175 [554] 1,025 [484] 1,050 [495] 1,000 [472] 1,025 [484] 1,025 [484] 1,025 [484] 1,000 [472] 1,050 [495] 1,025 [484] 1,050 [495] 1,025 [484] 1,025 [484] 1,025 [484] 1,050 [495] 1,025 [484] 1,050 [495] 1,075 [507] 1,200 [566] 1,175 [554] 1,000 [472] 1,025 [484] 1,075 [507] 1,075 [507] 1,050 [495] 1,050 [495] 1,175 [554] 1,025 [484] 1,000 [472] 1,075 [507] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,025 [484] 1,025 [484] 1,175 [554] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,050 [495] 1,050 [495] 1,200 [566] 1,200 [566] 1,100 [519] 1,100 [519] 1,100 [519] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,200 [566] 1,200 [566] 1,150 [543] 1,175 [554] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,050 [495] 1,000 [472] 1,025 [484] 1,000 [472] 1,050 [495] 1,025 [484] 1,025 [484] 1,025 [484] 1,025 [484] 1,025 [484] 1,050 [495] 1,000 [472] 1,050 [495] 1,050 [495] 1,025 [484] 1,000 [472] 1,025 [484] 1,025 [484] 1,150 [543] 1,200 [566] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-A*3621(RGRM-10?ZAJ?) 35,600 [10.4] RCFL-A*3621(RHWB-04WMX36A) 35,800 [10.5] RCFL-A*3621(RHWB-06WMX48A) 36,200 [10.6] RCFL-A*3621(ROCA-070E03) 36,200 [10.6] RCFL-A*3621(ROCA-070E04) 36,200 [10.6] RCFL-A*3621(ROLA-070E03) 36,200 [10.6] RCFL-A*3621(ROLA-070E04) 36,200 [10.6] RCFL-A*3621(ROLA-115E05) 36,400 [10.7] RCFL-A*3621+RXMD-C04 35,400 [10.4] RCFL-A*3821(RGFG-07?MCK?) 37,000 [10.8] RCFL-A*3821(RGFG-09?ZCM?) 38,000 [11.1] RCFL-A*3821(RGFG-10?ZCM?) 38,000 [11.1] RCFL-A*3821(RGLT-07?AMK?) 37,200 [10.9] RCFL-A*3821(RGPT-05?BMK?) 37,200 [10.9] RCFL-A*3821(RGPT-07?AMK?) 37,200 [10.9] RCFL-A*3821(ROCA-070E03) 37,600 [11.0] RCFL-A*3821(ROCA-070E04) 37,600 [11.0] RCFL-A*3821(ROLA-070E03) 37,600 [11.0] RCFL-A*3821(ROLA-070E04) 37,600 [11.0] RCFL-A*3821(ROLA-115E05) 38,000 [11.1] RCFL-A*3824(RGFG-09?ZCM?) 38,000 [11.1] RCFL-A*3824(RGFG-10?ZCM?) 37,800 [11.1] RCFL-A*3824(RGLT-12?ARM?) 37,800 [11.1] RCFL-A*3824(RGPT-12?ARM?) 38,000 [11.1] 036JEZ RCFL-A*3824(ROCA-070E03) 37,600 [11.0] RCFL-A*3824(ROCA-070E04) 37,600 [11.0] RCFL-A*3824(ROLA-070E03) 37,600 [11.0] RCFL-A*3824(ROLA-070E04) 37,600 [11.0] RCFL-A*3824(ROLA-115E05) 37,000 [10.8] RCFL-H*3617(RGFE-06?MCK?) 35,200 [10.3] RCFL-H*3617(RGFE-07?MCK?) 35,400 [10.4] RCFL-H*3617(RGFG-06?MCK?) 35,200 [10.3] RCFL-H*3617(RGFG-07?MCK?) 35,400 [10.4] RCFL-H*3617(RGGE-06?MCK?) 35,600 [10.4] RCFL-H*3617(RGGE-07?MCK?) 35,600 [10.4] RCFL-H*3617(RGJF-06?MCK?) 35,600 [10.4] RCFL-H*3617(RGJF-07?MCK?) 35,600 [10.4] RCFL-H*3617(RGLE-07?AMK?) 35,800 [10.5] RCFL-H*3617(RGLT-07?AMK?) 35,600 [10.4] RCFL-H*3617(RGPE-07?AMK?) 35,400 [10.4] RCFL-H*3617(RGPT-05?BMK?) 35,400 [10.4] RCFL-H*3617(RGPT-07?AMK?) 35,600 [10.4] RCFL-H*3617(RGRM-04?MAE?) 35,600 [10.4] RCFL-H*3617(RGRM-06?MAE?) 35,400 [10.4] RCFL-H*3617(RGTM-06?MAE?) 35,600 [10.4] RCFL-H*3617(RHWB-04WMX36A) 35,800 [10.5] RCFL-H*3617(RHWB-06WMX48A) 36,200 [10.6] RCFL-H*3617(ROCA-070E03) 36,200 [10.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 23,900 [7.0] 24,200 [7.1] 25,100 [7.4] 25,250 [7.4] 25,250 [7.4] 25,050 [7.3] 25,050 [7.3] 25,350 [7.4] 23,800 [7.0] 25,250 [7.4] 26,950 [7.9] 26,950 [7.9] 25,700 [7.5] 25,750 [7.5] 25,700 [7.5] 26,600 [7.8] 26,600 [7.8] 26,400 [7.7] 26,400 [7.7] 26,900 [7.9] 26,950 [7.9] 26,750 [7.8] 26,450 [7.7] 26,750 [7.8] 26,600 [7.8] 26,600 [7.8] 26,450 [7.7] 26,450 [7.7] 25,250 [7.4] 23,350 [6.8] 23,750 [7.0] 23,400 [6.9] 23,800 [7.0] 23,900 [7.0] 23,900 [7.0] 23,900 [7.0] 23,900 [7.0] 24,100 [7.1] 23,900 [7.0] 23,400 [6.9] 23,750 [7.0] 23,900 [7.0] 23,950 [7.0] 23,500 [6.9] 23,950 [7.0] 24,200 [7.1] 25,000 [7.3] 25,250 [7.4] 11,700 [3.4] 11,600 [3.4] 11,100 [3.3] 10,950 [3.2] 10,950 [3.2] 11,150 [3.3] 11,150 [3.3] 11,050 [3.2] 11,600 [3.4] 11,750 [3.4] 11,050 [3.2] 11,050 [3.2] 11,500 [3.4] 11,450 [3.4] 11,500 [3.4] 11,000 [3.2] 11,000 [3.2] 11,200 [3.3] 11,200 [3.3] 11,100 [3.3] 11,050 [3.2] 11,050 [3.2] 11,350 [3.3] 11,250 [3.3] 11,000 [3.2] 11,000 [3.2] 11,150 [3.3] 11,150 [3.3] 11,750 [3.4] 11,850 [3.5] 11,650 [3.4] 11,800 [3.5] 11,600 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 12,000 [3.5] 11,650 [3.4] 11,700 [3.4] 11,650 [3.4] 11,900 [3.5] 11,650 [3.4] 11,600 [3.4] 11,200 [3.3] 10,950 [3.2] 12.50 12.50 12.00 12.00 12.00 12.50 12.50 12.50 12.00 13.00 13.00 13.00 13.00 12.50 12.50 12.50 12.50 13.00 13.00 13.00 13.00 12.50 13.00 13.00 12.50 12.50 13.00 13.00 13.00 12.00 12.00 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.50 12.00 12.00 12.00 12.50 12.00 12.00 15.10 15.10 14.50 14.50 14.50 15.10 15.10 15.10 14.50 15.50 15.50 15.50 15.50 15.10 15.10 15.10 15.10 15.50 15.50 15.50 15.50 15.10 16.00 16.00 15.10 15.10 15.50 15.50 15.50 14.50 14.50 14.50 14.50 15.10 15.10 15.10 15.10 15.10 15.10 15.10 14.50 15.00 14.50 14.50 14.50 15.10 14.50 14.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 [ ] Designates Metric Conversions 15 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3617(ROCA-070E04) 36,200 [10.6] RCFL-H*3617(ROLA-070E03) 36,200 [10.6] RCFL-H*3617(ROLA-070E04) 35,800 [10.5] RCFL-H*3621(RGFE-06?MCK?) 35,200 [10.3] RCFL-H*3621(RGFE-07?MCK?) 35,600 [10.4] RCFL-H*3621(RGFE-09?ZCM?) 35,800 [10.5] RCFL-H*3621(RGFE-10?ZCM?) 35,600 [10.4] RCFL-H*3621(RGFG-06?MCK?) 35,200 [10.3] RCFL-H*3621(RGFG-07?MCK?) 35,400 [10.4] RCFL-H*3621(RGFG-09?ZCM?) 35,600 [10.4] RCFL-H*3621(RGFG-10?ZCM?) 35,800 [10.5] RCFL-H*3621(RGGE-06?MCK?) 35,600 [10.4] RCFL-H*3621(RGGE-07?MCK?) 35,600 [10.4] RCFL-H*3621(RGGE-09?ZCM?) 35,800 [10.5] RCFL-H*3621(RGGE-10?ZCM?) 35,600 [10.4] RCFL-H*3621(RGJF-06?MCK?) 35,600 [10.4] RCFL-H*3621(RGJF-07?MCK?) 35,600 [10.4] RCFL-H*3621(RGJF-09?ZCM?) 35,800 [10.5] RCFL-H*3621(RGJF-10?ZCM?) 35,600 [10.4] RCFL-H*3621(RGLE-07?AMK?) 35,800 [10.5] RCFL-H*3621(RGLE-07?BRQ?) 35,800 [10.5] RCFL-H*3621(RGLE-10?BRM?) 35,800 [10.5] RCFL-H*3621(RGLT-07?AMK?) 35,600 [10.4] RCFL-H*3621(RGLT-07?BRQ?) 36,400 [10.7] 036JEZ RCFL-H*3621(RGLT-10?BRM?) 36,400 [10.7] RCFL-H*3621(RGPE-07?AMK?) 35,400 [10.4] RCFL-H*3621(RGPE-07?BRQ?) 35,800 [10.5] RCFL-H*3621(RGPE-10?BRM?) 35,800 [10.5] RCFL-H*3621(RGPT-05?BMK?) 35,600 [10.4] RCFL-H*3621(RGPT-07?AMK?) 35,600 [10.4] RCFL-H*3621(RGPT-07?BRQ?) 36,000 [10.5] RCFL-H*3621(RGPT-10?BRM?) 36,400 [10.7] RCFL-H*3621(RGRM-04?MAE?) 35,600 [10.4] RCFL-H*3621(RGRM-06?MAE?) 35,400 [10.4] RCFL-H*3621(RGRM-09?ZAJ?) 35,600 [10.4] RCFL-H*3621(RGRM-10?ZAJ?) 35,600 [10.4] RCFL-H*3621(RGTM-06?MAE?) 35,600 [10.4] RCFL-H*3621(RGTM-07?RBG?) 35,800 [10.5] RCFL-H*3621(RGTM-09?ZAJ?) 36,000 [10.5] RCFL-H*3621(RHWB-04WMX36A) 35,800 [10.5] RCFL-H*3621(RHWB-06WMX48A) 36,200 [10.6] RCFL-H*3621(ROCA-070E03) 36,200 [10.6] RCFL-H*3621(ROCA-070E04) 36,200 [10.6] RCFL-H*3621(ROLA-070E03) 36,200 [10.6] RCFL-H*3621(ROLA-070E04) 36,200 [10.6] RCFL-H*3621(ROLA-115E05) 36,400 [10.7] RCFL-H*3621+RXMD-C04 35,400 [10.4] RCFL-H*3821(RGFE-09?ZCM?) 37,800 [11.1] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 16 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 25,250 [7.4] 25,050 [7.3] 24,100 [7.1] 23,350 [6.8] 23,950 [7.0] 24,100 [7.1] 23,900 [7.0] 23,400 [6.9] 23,800 [7.0] 24,000 [7.0] 24,000 [7.0] 23,900 [7.0] 23,900 [7.0] 24,050 [7.0] 23,900 [7.0] 23,900 [7.0] 23,900 [7.0] 24,050 [7.0] 23,900 [7.0] 24,050 [7.0] 24,050 [7.0] 24,000 [7.0] 23,900 [7.0] 25,350 [7.4] 25,200 [7.4] 23,400 [6.9] 24,050 [7.0] 24,050 [7.0] 23,950 [7.0] 23,900 [7.0] 24,200 [7.1] 25,200 [7.4] 23,950 [7.0] 23,500 [6.9] 23,950 [7.0] 23,900 [7.0] 23,950 [7.0] 24,050 [7.0] 24,500 [7.2] 24,200 [7.1] 25,100 [7.4] 25,250 [7.4] 25,250 [7.4] 25,050 [7.3] 25,050 [7.3] 25,350 [7.4] 23,800 [7.0] 26,800 [7.9] 10,950 [3.2] 11,150 [3.3] 11,700 [3.4] 11,850 [3.5] 11,650 [3.4] 11,700 [3.4] 11,700 [3.4] 11,800 [3.5] 11,600 [3.4] 11,600 [3.4] 11,800 [3.5] 11,700 [3.4] 11,700 [3.4] 11,750 [3.4] 11,700 [3.4] 11,700 [3.4] 11,700 [3.4] 11,750 [3.4] 11,700 [3.4] 11,750 [3.4] 11,750 [3.4] 11,800 [3.5] 11,700 [3.4] 11,050 [3.2] 11,200 [3.3] 12,000 [3.5] 11,750 [3.4] 11,750 [3.4] 11,650 [3.4] 11,700 [3.4] 11,800 [3.5] 11,200 [3.3] 11,650 [3.4] 11,900 [3.5] 11,650 [3.4] 11,700 [3.4] 11,650 [3.4] 11,750 [3.4] 11,500 [3.4] 11,600 [3.4] 11,100 [3.3] 10,950 [3.2] 10,950 [3.2] 11,150 [3.3] 11,150 [3.3] 11,050 [3.2] 11,600 [3.4] 11,000 [3.2] 12.00 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 13.00 13.00 12.50 12.50 12.50 12.50 13.00 13.00 12.00 12.50 13.00 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.00 12.50 12.50 12.50 12.00 12.50 SEER Sound Rating dB Indoor CFM [L/s] 14.50 15.00 15.10 14.50 14.50 15.10 15.10 15.00 15.00 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.10 15.50 15.50 15.10 15.10 15.10 15.10 15.50 15.50 14.50 15.10 15.50 15.10 14.50 14.50 15.00 15.10 15.00 15.10 15.10 15.10 14.50 14.50 14.50 15.10 15.10 15.10 14.50 15.10 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,200 [566] 1,175 [554] 1,025 [484] 1,000 [472] 1,025 [484] 1,025 [484] 1,025 [484] 1,000 [472] 1,050 [495] 1,025 [484] 1,050 [495] 1,025 [484] 1,025 [484] 1,025 [484] 1,050 [495] 1,025 [484] 1,025 [484] 1,025 [484] 1,050 [495] 1,025 [484] 1,025 [484] 1,050 [495] 1,075 [507] 1,200 [566] 1,175 [554] 1,000 [472] 1,025 [484] 1,075 [507] 1,075 [507] 1,050 [495] 1,050 [495] 1,175 [554] 1,025 [484] 1,000 [472] 1,075 [507] 1,025 [484] 1,025 [484] 1,050 [495] 1,100 [519] 1,025 [484] 1,175 [554] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,050 [495] 1,200 [566] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,000 [472] 1,050 [495] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,050 [495] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,100 [519] 1,100 [519] 1,100 [519] 1,050 [495] 1,075 [507] 1,150 [543] 1,075 [507] 1,050 [495] 1,100 [519] 1,075 [507] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,050 [495] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,075 [507] 1,150 [543] 1,075 [507] 1,075 [507] 1,175 [554] 1,050 [495] 1,075 [507] 1,150 [543] 1,075 [507] 1,050 [495] 1,100 [519] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3821(RGFG-06?MCK?) 36,800 [10.8] RCFL-H*3821(RGFG-07?MCK?) 37,000 [10.8] RCFL-H*3821(RGFG-09?ZCM?) 38,000 [11.1] RCFL-H*3821(RGFG-10?ZCM?) 38,000 [11.1] RCFL-H*3821(RGGE-06?MCK?) 37,600 [11.0] RCFL-H*3821(RGGE-07?MCK?) 37,400 [11.0] RCFL-H*3821(RGGE-10?ZCM?) 37,000 [10.8] RCFL-H*3821(RGJF-06?MCK?) 37,600 [11.0] RCFL-H*3821(RGJF-07?MCK?) 37,400 [11.0] RCFL-H*3821(RGJF-10?ZCM?) 37,800 [11.1] RCFL-H*3821(RGLE-07?AMK?) 37,600 [11.0] RCFL-H*3821(RGLE-10?BRM?) 38,000 [11.1] RCFL-H*3821(RGLT-07?AMK?) 37,200 [10.9] RCFL-H*3821(RGPT-05?BMK?) 37,200 [10.9] RCFL-H*3821(RGPT-07?AMK?) 37,200 [10.9] RCFL-H*3821(RGRM-07?YBG?) 36,600 [10.7] RCFL-H*3821(RGRM-09?ZAJ?) 37,000 [10.8] RCFL-H*3821(RGRM-10?ZAJ?) 37,400 [11.0] RCFL-H*3821(RGTM-06?MAE?) 36,800 [10.8] RCFL-H*3821(RGTM-07?RBG?) 37,000 [10.8] RCFL-H*3821(RGTM-09?ZAJ?) 37,400 [11.0] RCFL-H*3821(RHWB-04WMX36A) 36,200 [10.6] RCFL-H*3821(RHWB-06WMX48A) 37,000 [10.8] RCFL-H*3821(ROCA-070E03) 37,600 [11.0] 036JEZ RCFL-H*3821(ROCA-070E04) 37,600 [11.0] RCFL-H*3821(ROLA-070E03) 37,600 [11.0] RCFL-H*3821(ROLA-070E04) 37,600 [11.0] RCFL-H*3821(ROLA-115E05) 38,000 [11.1] RCFL-H*3821+RXMD-C04 36,400 [10.7] RCFL-H*3824(RGFE-09?ZCM?) 37,600 [11.0] RCFL-H*3824(RGFG-09?ZCM?) 38,000 [11.1] RCFL-H*3824(RGFG-10?ZCM?) 37,800 [11.1] RCFL-H*3824(RGGE-10?ZCM?) 37,800 [11.1] RCFL-H*3824(RGGE-12?RCM?) 38,000 [11.1] RCFL-H*3824(RGJF-10?ZCM?) 37,800 [11.1] RCFL-H*3824(RGJF-12?RCM?) 38,000 [11.1] RCFL-H*3824(RGLE-10?BRM?) 38,000 [11.1] RCFL-H*3824(RGLE-12?ARM?) 37,200 [10.9] RCFL-H*3824(RGLT-12?ARM?) 37,800 [11.1] RCFL-H*3824(RGPE-10?BRM?) 37,200 [10.9] RCFL-H*3824(RGPE-12?ARM?) 37,200 [10.9] RCFL-H*3824(RGPT-12?ARM?) 38,000 [11.1] RCFL-H*3824(RGRM-07?YBG?) 36,600 [10.7] RCFL-H*3824(RGRM-09?ZAJ?) 36,800 [10.8] RCFL-H*3824(RGRM-10?ZAJ?) 37,400 [11.0] RCFL-H*3824(RGRM-12?RAJ?) 37,000 [10.8] RCFL-H*3824(RGTM-07?RBG?) 37,000 [10.8] RCFL-H*3824(RGTM-09?ZAJ?) 37,400 [11.0] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 25,000 [7.3] 25,250 [7.4] 26,950 [7.9] 26,950 [7.9] 26,650 [7.8] 26,450 [7.7] 25,250 [7.4] 26,650 [7.8] 26,450 [7.7] 26,750 [7.8] 26,600 [7.8] 26,900 [7.9] 25,700 [7.5] 25,750 [7.5] 25,700 [7.5] 24,950 [7.3] 25,300 [7.4] 26,150 [7.7] 25,100 [7.4] 25,250 [7.4] 25,850 [7.6] 24,700 [7.2] 26,200 [7.7] 26,600 [7.8] 26,600 [7.8] 26,400 [7.7] 26,400 [7.7] 26,900 [7.9] 24,800 [7.3] 26,600 [7.8] 26,950 [7.9] 26,750 [7.8] 26,800 [7.9] 26,900 [7.9] 26,750 [7.8] 26,900 [7.9] 26,900 [7.9] 25,400 [7.4] 26,450 [7.7] 25,400 [7.4] 25,400 [7.4] 26,750 [7.8] 24,950 [7.3] 25,100 [7.4] 26,150 [7.7] 25,250 [7.4] 25,250 [7.4] 25,850 [7.6] 11,800 [3.5] 11,750 [3.4] 11,050 [3.2] 11,050 [3.2] 10,950 [3.2] 10,950 [3.2] 11,750 [3.4] 10,950 [3.2] 10,950 [3.2] 11,050 [3.2] 11,000 [3.2] 11,100 [3.3] 11,500 [3.4] 11,450 [3.4] 11,500 [3.4] 11,650 [3.4] 11,700 [3.4] 11,250 [3.3] 11,700 [3.4] 11,750 [3.4] 11,550 [3.4] 11,500 [3.4] 10,800 [3.2] 11,000 [3.2] 11,000 [3.2] 11,200 [3.3] 11,200 [3.3] 11,100 [3.3] 11,600 [3.4] 11,000 [3.2] 11,050 [3.2] 11,050 [3.2] 11,000 [3.2] 11,100 [3.3] 11,050 [3.2] 11,100 [3.3] 11,100 [3.3] 11,800 [3.5] 11,350 [3.3] 11,800 [3.5] 11,800 [3.5] 11,250 [3.3] 11,650 [3.4] 11,700 [3.4] 11,250 [3.3] 11,750 [3.4] 11,750 [3.4] 11,550 [3.4] 13.00 13.00 13.00 12.50 12.00 12.00 13.00 12.00 12.00 12.50 12.50 13.00 13.00 12.50 12.50 12.00 12.50 12.50 12.50 13.00 13.00 13.00 12.50 12.50 12.50 13.00 13.00 13.00 12.00 12.50 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 12.50 13.00 13.00 13.00 15.50 15.50 15.50 15.10 14.50 14.50 15.50 14.50 14.50 15.10 15.10 15.50 15.50 15.10 15.10 14.50 15.10 15.10 15.10 15.50 15.50 15.50 15.10 15.10 15.10 15.50 15.50 15.50 14.50 15.10 15.50 15.10 15.00 15.50 15.00 15.50 15.50 16.00 16.00 16.00 16.00 16.00 14.50 15.10 15.10 15.50 15.50 15.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 [ ] Designates Metric Conversions 17 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3824(RGTM-10?RBJ?) 37,600 [11.0] RCFL-H*3824(ROCA-070E03) 37,600 [11.0] RCFL-H*3824(ROCA-070E04) 37,600 [11.0] RCFL-H*3824(ROLA-070E03) 37,600 [11.0] RCFL-H*3824(ROLA-070E04) 37,600 [11.0] RCFL-H*3824(ROLA-115E05) 37,000 [10.8] RCFL-H*3824+RXMD-C04 36,400 [10.7] RCFN-H*3624(RGFE-09?ZCM?) 39,500 [11.6] RCFN-H*3624(RGFE-10?ZCM?) 39,500 [11.6] RCFN-H*3624(RGFE-12?RCM?) 39,500 [11.6] RCFN-H*3624(RGFG-09?ZCM?) 40,500 [11.9] RCFN-H*3624(RGFG-10?ZCM?) 40,500 [11.9] RCFN-H*3624(RGFG-12?RCM?) 41,000 [12.0] RCFN-H*3624(RGGE-09?ZCM?) 39,500 [11.6] RCFN-H*3624(RGGE-10?ZCM?) 39,500 [11.6] RCFN-H*3624(RGGE-12?RCM?) 39,500 [11.6] RCFN-H*3624(RGJF-09?ZCM?) 39,500 [11.6] RCFN-H*3624(RGJF-10?ZCM?) 39,500 [11.6] RCFN-H*3624(RGJF-12?RCM?) 39,500 [11.6] RCFN-H*3624(RGLE-07?BRQ?) 39,500 [11.6] RCFN-H*3624(RGLE-10?BRM?) 39,500 [11.6] RCFN-H*3624(RGLE-12?ARM?) 39,500 [11.6] RCFN-H*3624(RGLT-07?BRQ?) 40,000 [11.7] RCFN-H*3624(RGLT-10?BRM?) 40,000 [11.7] 036JEZ RCFN-H*3624(RGLT-12?ARM?) 40,000 [11.7] RCFN-H*3624(RGPE-07?BRQ?) 39,500 [11.6] RCFN-H*3624(RGPE-10?BRM?) 39,500 [11.6] RCFN-H*3624(RGPE-12?ARM?) 39,500 [11.6] RCFN-H*3624(RGPT-07?BRQ?) 40,000 [11.7] RCFN-H*3624(RGPT-10?BRM?) 40,000 [11.7] RCFN-H*3624(RGPT-12?ARM?) 39,500 [11.6] RCFN-H*3624(RGRM-09?ZAJ?) 39,000 [11.4] RCFN-H*3624(RGRM-10?ZAJ?) 39,000 [11.4] RCFN-H*3624(RGRM-12?RAJ?) 39,500 [11.6] RCFN-H*3624(ROCA-070E03) 39,500 [11.6] RCFN-H*3624(ROCA-070E04) 39,500 [11.6] RCFN-H*3624(ROLA-070E03) 39,500 [11.6] RCFN-H*3624(ROLA-070E04) 39,500 [11.6] RCFN-H*3624(ROLA-115E05) 39,500 [11.6] RCFN-H*3624+RXMD-C04 39,000 [11.4] RBHP-21(RCHL-36A1) 35,600 [10.4] RCQD-3621(RGFE-09?ZCM?) 37,400 [11.0] RCQD-3621(RGFG-07?MCK?) 36,800 [10.8] RCQD-3621(RGFG-09?ZCM?) 37,600 [11.0] RCQD-3621(RGFG-10?ZCM?) 37,000 [10.8] RCQD-3621(RGJF-06?MCK?) 37,200 [10.9] RCQD-3621(RGJF-07?MCK?) 37,200 [10.9] RCQD-3621(RGJF-10?ZCM?) 37,400 [11.0] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 18 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 26,150 [7.7] 26,600 [7.8] 26,600 [7.8] 26,450 [7.7] 26,450 [7.7] 25,250 [7.4] 24,800 [7.3] 29,050 [8.5] 29,100 [8.5] 29,050 [8.5] 30,750 [9.0] 30,750 [9.0] 31,350 [9.2] 29,050 [8.5] 29,050 [8.5] 29,000 [8.5] 29,050 [8.5] 29,050 [8.5] 29,000 [8.5] 29,000 [8.5] 29,000 [8.5] 29,000 [8.5] 29,900 [8.8] 29,900 [8.8] 29,450 [8.6] 29,000 [8.5] 29,000 [8.5] 29,000 [8.5] 29,900 [8.8] 29,750 [8.7] 29,000 [8.5] 28,600 [8.4] 28,350 [8.3] 29,050 [8.5] 29,100 [8.5] 29,100 [8.5] 29,000 [8.5] 29,000 [8.5] 29,000 [8.5] 28,700 [8.4] 24,100 [7.1] 26,750 [7.8] 25,400 [7.4] 26,850 [7.9] 25,550 [7.5] 26,600 [7.8] 26,600 [7.8] 26,700 [7.8] 11,450 [3.4] 11,000 [3.2] 11,000 [3.2] 11,150 [3.3] 11,150 [3.3] 11,750 [3.4] 11,600 [3.4] 10,450 [3.1] 10,400 [3.0] 10,450 [3.1] 9,750 [2.9] 9,750 [2.9] 9,650 [2.8] 10,450 [3.1] 10,450 [3.1] 10,500 [3.1] 10,450 [3.1] 10,450 [3.1] 10,500 [3.1] 10,500 [3.1] 10,500 [3.1] 10,500 [3.1] 10,100 [3.0] 10,100 [3.0] 10,550 [3.1] 10,500 [3.1] 10,500 [3.1] 10,500 [3.1] 10,100 [3.0] 10,250 [3.0] 10,500 [3.1] 10,400 [3.0] 10,650 [3.1] 10,450 [3.1] 10,400 [3.0] 10,400 [3.0] 10,500 [3.1] 10,500 [3.1] 10,500 [3.1] 10,300 [3.0] 11,500 [3.4] 10,650 [3.1] 11,400 [3.3] 10,750 [3.1] 11,450 [3.4] 10,600 [3.1] 10,600 [3.1] 10,700 [3.1] 13.00 12.50 12.50 13.00 13.00 13.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 12.50 12.50 12.50 13.00 12.00 11.50 12.50 SEER Sound Rating dB Indoor CFM [L/s] 15.50 15.10 15.10 15.50 15.50 15.50 14.50 15.50 15.50 16.00 16.00 16.00 16.00 15.50 15.50 16.00 15.50 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.50 16.00 16.00 16.00 16.00 16.00 16.00 15.50 15.50 15.50 15.50 15.50 16.00 16.00 16.00 15.00 15.00 15.10 15.10 15.10 15.50 14.50 14.00 15.10 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,125 [531] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,050 [495] 1,050 [495] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,225 [578] 1,275 [602] 1,275 [602] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,275 [602] 1,250 [590] 1,200 [566] 1,225 [578] 1,150 [543] 1,225 [578] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,050 [495] 1,200 [566] 1,050 [495] 1,200 [566] 1,200 [566] 1,200 [566] Air Performance Data RAPM- JEZ Series SEER Sound Rating dB Indoor CFM [L/s] 14.50 15.50 15.50 14.50 15.10 15.50 15.50 14.00 14.50 15.10 15.00 15.10 14.50 14.50 15.10 15.10 15.50 14.00 15.10 15.10 15.50 15.10 15.50 15.50 15.50 15.50 15.50 15.50 14.50 15.10 15.10 15.50 15.00 15.00 15.10 15.10 15.50 14.00 15.50 15.50 14.50 14.50 16.00 16.00 16.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,200 [566] 1,050 [495] 1,075 [507] 1,100 [519] 1,100 [519] 1,050 [495] 1,050 [495] 1,175 [554] 1,050 [495] 1,075 [507] 1,150 [543] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,050 [495] 1,045 [493] 1,200 [566] 1,200 [566] 1,050 [495] 1,200 [566] 1,200 [566] 1,050 [495] 1,075 [507] 1,075 [507] 1,050 [495] 1,075 [507] 1,050 [495] 1,075 [507] 1,150 [543] 1,075 [507] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,050 [495] 1,045 [493] 1,025 [484] 1,000 [472] 1,100 [519] 1,100 [519] 1,200 [566] 1,175 [554] 1,200 [566] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 036JEZ Indoor Coil and/or Air Handler RCQD-3621(RGPE-05?BMK?) RCQD-3621(RGPE-07?BRQ?) RCQD-3621(RGPE-10?BRM?) RCQD-3621(RGPT-05?BMK?) RCQD-3621(RGPT-07?AMK?) RCQD-3621(RGPT-07?BRQ?) RCQD-3621(RGPT-10?BRM?) RCQD-3621(RGRM-06?MAE?) RCQD-3621(RGRM-07?YBG?) RCQD-3621(RGRM-09?ZAJ?) RCQD-3621(RGRM-10?ZAJ?) RCQD-3621(RHWB-04WMX36A) RCQD-3621(ROCA-070E03) RCQD-3621(ROCA-070E04) RCQD-3621(ROLA-070E03) RCQD-3621(ROLA-070E04) RCQD-3621(ROLA-115E05) RCQD-3621+RXMD-C04 RCQD-3624(RGFE-09?ZCM?) RCQD-3624(RGFG-09?ZCM?) RCQD-3624(RGFG-10?ZCM?) RCQD-3624(RGJF-10?ZCM?) RCQD-3624(RGJF-12?RCM?) RCQD-3624(RGPE-07?BRQ?) RCQD-3624(RGPE-10?BRM?) RCQD-3624(RGPE-12?ARM?) RCQD-3624(RGPT-07?BRQ?) RCQD-3624(RGPT-10?BRM?) RCQD-3624(RGRM-07?YBG?) RCQD-3624(RGRM-09?ZAJ?) RCQD-3624(RGRM-10?ZAJ?) RCQD-3624(RGRM-12?RAJ?) RCQD-3624(ROCA-070E03) RCQD-3624(ROCA-070E04) RCQD-3624(ROLA-070E03) RCQD-3624(ROLA-070E04) RCQD-3624(ROLA-115E05) RCQD-3624+RXMD-C04 RHKL-HM3617(RCSL-H*3617) RHLL-HM3617(RCSL-H*3617) RHSL-HM3617(RCSL-H*3617) RHSL-HM3621(RCSL-H*3621) RHKL-HM3821(RCSL-H*3821) RHLL-HM3821(RCSL-H*3821) RHPN-HM3624(RCSN-H*3624) Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] 37,200 [10.9] 36,800 [10.8] 37,000 [10.8] 36,800 [10.8] 37,000 [10.8] 37,000 [10.8] 37,000 [10.8] 37,600 [11.0] 36,400 [10.7] 36,800 [10.8] 37,800 [11.1] 38,500 [11.3] 37,400 [11.0] 37,400 [11.0] 37,400 [11.0] 37,400 [11.0] 36,800 [10.8] 36,200 [10.6] 37,400 [11.0] 37,600 [11.0] 37,000 [10.8] 37,400 [11.0] 37,600 [11.0] 36,800 [10.8] 37,000 [10.8] 37,200 [10.9] 37,000 [10.8] 37,200 [10.9] 36,400 [10.7] 36,800 [10.8] 38,000 [11.1] 37,000 [10.8] 37,400 [11.0] 37,400 [11.0] 37,400 [11.0] 37,400 [11.0] 36,800 [10.8] 36,200 [10.6] 36,000 [10.5] 35,800 [10.5] 35,600 [10.4] 35,600 [10.4] 38,000 [11.1] 37,800 [11.1] 40,000 [11.7] 26,600 [7.8] 25,350 [7.4] 25,650 [7.5] 25,700 [7.5] 25,850 [7.6] 25,500 [7.5] 25,500 [7.5] 27,750 [8.1] 25,100 [7.4] 25,550 [7.5] 27,700 [8.1] 28,900 [8.5] 26,750 [7.8] 26,750 [7.8] 26,550 [7.8] 26,550 [7.8] 25,350 [7.4] 24,950 [7.3] 26,700 [7.8] 26,850 [7.9] 25,550 [7.5] 26,700 [7.8] 26,850 [7.9] 25,350 [7.4] 25,650 [7.5] 25,850 [7.6] 25,500 [7.5] 25,850 [7.6] 25,050 [7.3] 25,550 [7.5] 27,800 [8.1] 25,700 [7.5] 26,750 [7.8] 26,750 [7.8] 26,550 [7.8] 26,550 [7.8] 25,350 [7.4] 24,950 [7.3] 24,200 [7.1] 23,800 [7.0] 24,200 [7.1] 24,200 [7.1] 26,900 [7.9] 26,600 [7.8] 29,450 [8.6] 10,600 [3.1] 11,450 [3.4] 11,350 [3.3] 11,100 [3.3] 11,150 [3.3] 11,500 [3.4] 11,500 [3.4] 9,850 [2.9] 11,300 [3.3] 11,250 [3.3] 10,100 [3.0] 9,600 [2.8] 10,650 [3.1] 10,650 [3.1] 10,850 [3.2] 10,850 [3.2] 11,450 [3.4] 11,250 [3.3] 10,700 [3.1] 10,750 [3.1] 11,450 [3.4] 10,700 [3.1] 10,750 [3.1] 11,450 [3.4] 11,350 [3.3] 11,350 [3.3] 11,500 [3.4] 11,350 [3.3] 11,350 [3.3] 11,250 [3.3] 10,200 [3.0] 11,300 [3.3] 10,650 [3.1] 10,650 [3.1] 10,850 [3.2] 10,850 [3.2] 11,450 [3.4] 11,250 [3.3] 11,800 [3.5] 12,000 [3.5] 11,400 [3.3] 11,400 [3.3] 11,100 [3.3] 11,200 [3.3] 10,550 [3.1] EER 12.00 13.00 13.00 12.00 12.50 13.00 13.00 12.50 12.00 12.50 12.50 12.50 12.00 12.00 12.50 12.50 13.00 11.50 12.50 12.50 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 12.00 12.50 12.50 13.00 12.50 12.50 12.50 12.50 13.00 11.50 13.00 13.00 12.00 12.00 13.00 13.00 13.00 ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 19 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] 39,500 [11.6] RCFL-H*4821+RXMD-C04 ➀ RCFL-A*3821(RGLT-07?AMK?) 40,000 [11.7] RCFL-A*3821(RGLT-07?BRQ?) 40,000 [11.7] RCFL-A*3821(RGLT-10?BRM?) 40,000 [11.7] RCFL-A*3821(RGPE-07?AMK?) 40,500 [11.9] RCFL-A*3821(RGPT-05?BMK?) 39,500 [11.6] RCFL-A*3821(RGPT-07?AMK?) 39,500 [11.6] RCFL-A*3821(RGPT-07?BRQ?) 40,000 [11.7] RCFL-A*3821(RGPT-10?BRM?) 40,000 [11.7] RCFL-A*3821(ROCA-070E03) 39,500 [11.6] RCFL-A*3821(ROCA-070E04) 39,500 [11.6] RCFL-A*3821(ROLA-070E03) 39,500 [11.6] RCFL-A*3821(ROLA-070E04) 39,500 [11.6] RCFL-A*4821(RGFE-09?ZCM?) 39,500 [11.6] RCFL-A*4821(RGFE-10?ZCM?) 40,000 [11.7] RCFL-A*4821(RGFG-09?ZCM?) 39,500 [11.6] RCFL-A*4821(RGFG-10?ZCM?) 39,500 [11.6] RCFL-A*4821(RGGE-06?MCK?) 39,500 [11.6] RCFL-A*4821(RGGE-07?MCK?) 39,500 [11.6] RCFL-A*4821(RGGE-09?ZCM?) 40,000 [11.7] RCFL-A*4821(RGGE-10?ZCM?) 39,500 [11.6] RCFL-A*4821(RGLE-07?AMK?) 39,500 [11.6] RCFL-A*4821(RGLE-10?BRM?) 40,500 [11.9] RCFL-A*4821(RGLT-07?AMK?) 40,000 [11.7] 042JEZ RCFL-A*4821(RGLT-07?BRQ?) 40,000 [11.7] RCFL-A*4821(RGLT-10?BRM?) 40,000 [11.7] RCFL-A*4821(RGPE-05?BMK?) 39,500 [11.6] RCFL-A*4821(RGPE-07?AMK?) 40,000 [11.7] RCFL-A*4821(RGPE-07?BRQ?) 40,000 [11.7] RCFL-A*4821(RGPE-10?BRM?) 40,000 [11.7] RCFL-A*4821(RGPT-05?BMK?) 39,500 [11.6] RCFL-A*4821(RGPT-07?AMK?) 39,500 [11.6] RCFL-A*4821(RGPT-07?BRQ?) 40,000 [11.7] RCFL-A*4821(RGPT-10?BRM?) 40,000 [11.7] RCFL-A*4821(RGTM-06?MAE?) 39,500 [11.6] RCFL-A*4821(RGTM-07?RBG?) 39,500 [11.6] RCFL-A*4821(RGTM-09?ZAJ?) 40,000 [11.7] RCFL-A*4821(RHWB-04WMX36A) 39,500 [11.6] RCFL-A*4821(RHWB-06WMX48A) 39,500 [11.6] RCFL-A*4821(ROCA-070E03) 39,500 [11.6] RCFL-A*4821(ROCA-070E04) 39,500 [11.6] RCFL-A*4821(ROLA-070E03) 39,500 [11.6] RCFL-A*4821(ROLA-070E04) 39,500 [11.6] RCFL-A*4821+RXMD-C04 39,500 [11.6] RCFL-A*4824(RGFE-09?ZCM?) 39,500 [11.6] RCFL-A*4824(RGFE-10?ZCM?) 40,000 [11.7] RCFL-A*4824(RGFE-12?RCM?) 40,000 [11.7] RCFL-A*4824(RGFG-09?ZCM?) 39,500 [11.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 20 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 27,500 [8.1] 27,900 [8.2] 27,800 [8.1] 27,800 [8.1] 27,900 [8.2] 27,450 [8.0] 27,450 [8.0] 27,800 [8.1] 27,800 [8.1] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,150 [8.0] 27,900 [8.2] 27,400 [8.0] 27,200 [8.0] 27,200 [8.0] 27,200 [8.0] 27,850 [8.2] 27,150 [8.0] 27,150 [8.0] 29,150 [8.5] 27,900 [8.2] 27,800 [8.1] 27,800 [8.1] 27,200 [8.0] 27,900 [8.2] 27,800 [8.1] 27,800 [8.1] 27,450 [8.0] 27,450 [8.0] 27,800 [8.1] 27,800 [8.1] 27,500 [8.1] 26,700 [7.8] 27,850 [8.2] 27,300 [8.0] 27,300 [8.0] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,500 [8.1] 27,150 [8.0] 27,900 [8.2] 27,850 [8.2] 27,400 [8.0] 12,000 [3.5] 12,100 [3.5] 12,200 [3.6] 12,200 [3.6] 12,600 [3.7] 12,050 [3.5] 12,050 [3.5] 12,200 [3.6] 12,200 [3.6] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,350 [3.6] 12,100 [3.5] 12,100 [3.5] 12,300 [3.6] 12,300 [3.6] 12,300 [3.6] 12,150 [3.6] 12,350 [3.6] 12,350 [3.6] 11,350 [3.3] 12,100 [3.5] 12,200 [3.6] 12,200 [3.6] 12,300 [3.6] 12,100 [3.5] 12,200 [3.6] 12,200 [3.6] 12,050 [3.5] 12,050 [3.5] 12,200 [3.6] 12,200 [3.6] 12,000 [3.5] 12,800 [3.8] 12,150 [3.6] 12,200 [3.6] 12,200 [3.6] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,000 [3.5] 12,350 [3.6] 12,100 [3.5] 12,150 [3.6] 12,100 [3.5] 12.00 12.50 13.00 13.00 12.50 12.00 12.00 13.00 13.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 13.00 13.00 12.00 12.50 13.00 13.00 12.00 12.00 13.00 13.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.50 12.50 SEER Sound Rating dB Indoor CFM [L/s] 14.50 15.10 15.50 15.50 15.10 14.50 14.50 15.50 15.50 15.10 15.10 15.50 15.50 15.10 15.10 15.10 15.10 14.50 14.50 15.50 15.10 15.10 15.50 15.10 15.50 15.50 14.50 15.10 15.50 15.50 14.50 14.50 15.50 15.50 14.50 15.50 15.10 15.10 15.10 15.10 15.10 15.50 15.50 14.50 15.10 15.10 15.50 15.10 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,250 [590] 1,250 [590] 1,250 [590] 1,250 [590] 1,225 [578] 1,225 [578] 1,250 [590] 1,250 [590] 1,225 [578] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,400 [661] 1,250 [590] 1,250 [590] 1,250 [590] 1,200 [566] 1,225 [578] 1,225 [578] 1,225 [578] 1,225 [578] 1,250 [590] 1,250 [590] 1,225 [578] 1,225 [578] 1,125 [531] 1,250 [590] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,250 [590] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,250 [590] 1,250 [590] 1,150 [543] 1,225 [578] 1,225 [578] 1,425 [672] 1,225 [578] 1,225 [578] 1,175 [554] 1,225 [578] 1,150 [543] 1,225 [578] 1,350 [637] 1,400 [661] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,250 [590] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,250 [590] 1,250 [590] 1,250 [590] 1,200 [566] 1,225 [578] 1,225 [578] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-A*4824(RGFG-10?ZCM?) 39,500 [11.6] RCFL-A*4824(RGFG-12?RCM?) 40,000 [11.7] RCFL-A*4824(RGGE-09?ZCM?) 40,000 [11.7] RCFL-A*4824(RGGE-10?ZCM?) 39,500 [11.6] RCFL-A*4824(RGGE-12?RCM?) 40,000 [11.7] RCFL-A*4824(RGLE-10?BRM?) 40,000 [11.7] RCFL-A*4824(RGLE-12?ARM?) 40,000 [11.7] RCFL-A*4824(RGLT-07?BRQ?) 40,000 [11.7] RCFL-A*4824(RGLT-10?BRM?) 40,000 [11.7] RCFL-A*4824(RGLT-12?ARM?) 39,500 [11.6] RCFL-A*4824(RGPE-07?BRQ?) 40,000 [11.7] RCFL-A*4824(RGPE-10?BRM?) 40,000 [11.7] RCFL-A*4824(RGPE-12?ARM?) 41,000 [12.0] RCFL-A*4824(RGPT-07?BRQ?) 40,000 [11.7] RCFL-A*4824(RGPT-10?BRM?) 40,000 [11.7] RCFL-A*4824(RGPT-12?ARM?) 40,000 [11.7] RCFL-A*4824(RGRM-09?ZAJ?) 40,000 [11.7] RCFL-A*4824(RGRM-10?ZAJ?) 39,500 [11.6] RCFL-A*4824(RGRM-12?RAJ?) 40,000 [11.7] RCFL-A*4824(RHWB-08WRX60A) 40,500 [11.9] RCFL-A*4824(RHWB-10WRX60A) 41,000 [12.0] RCFL-A*4824(ROCA-070E03) 39,500 [11.6] RCFL-A*4824(ROCA-070E04) 39,500 [11.6] RCFL-A*4824(ROLA-070E03) 39,500 [11.6] 042JEZ RCFL-A*4824(ROLA-070E04) 39,500 [11.6] RCFL-A*4824(ROLA-115E05) 40,000 [11.7] RCFL-A*4824+RXMD-C04 39,500 [11.6] RCFL-H*3821(RGFE-09?ZCM?) 40,500 [11.9] RCFL-H*3821(RGFE-10?ZCM?) 40,500 [11.9] RCFL-H*3821(RGFG-09?ZCM?) 39,500 [11.6] RCFL-H*3821(RGFG-10?ZCM?) 39,500 [11.6] RCFL-H*3821(RGGE-06?MCK?) 40,500 [11.9] RCFL-H*3821(RGGE-07?MCK?) 40,500 [11.9] RCFL-H*3821(RGGE-09?ZCM?) 40,500 [11.9] RCFL-H*3821(RGGE-10?ZCM?) 40,500 [11.9] RCFL-H*3821(RGJF-06?MCK?) 40,500 [11.9] RCFL-H*3821(RGJF-07?MCK?) 40,500 [11.9] RCFL-H*3821(RGJF-09?ZCM?) 40,500 [11.9] RCFL-H*3821(RGJF-10?ZCM?) 40,500 [11.9] RCFL-H*3821(RGLE-07?AMK?) 40,500 [11.9] RCFL-H*3821(RGLE-07?BRQ?) 40,500 [11.9] RCFL-H*3821(RGLE-10?BRM?) 41,000 [12.0] RCFL-H*3821(RGLT-07?AMK?) 40,000 [11.7] RCFL-H*3821(RGLT-07?BRQ?) 40,000 [11.7] RCFL-H*3821(RGLT-10?BRM?) 40,000 [11.7] RCFL-H*3821(RGPE-05?BMK?) 40,500 [11.9] RCFL-H*3821(RGPE-07?AMK?) 40,500 [11.9] RCFL-H*3821(RGPE-07?BRQ?) 41,000 [12.0] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 27,200 [8.0] 28,000 [8.2] 27,850 [8.2] 27,150 [8.0] 27,550 [8.1] 27,550 [8.1] 27,800 [8.1] 27,800 [8.1] 27,800 [8.1] 26,750 [7.8] 27,800 [8.1] 27,800 [8.1] 29,800 [8.7] 27,800 [8.1] 27,800 [8.1] 27,400 [8.0] 27,900 [8.2] 26,900 [7.9] 27,850 [8.2] 29,000 [8.5] 29,800 [8.7] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,550 [8.1] 27,500 [8.1] 27,850 [8.2] 27,850 [8.2] 27,200 [8.0] 27,200 [8.0] 27,900 [8.2] 27,900 [8.2] 28,000 [8.2] 27,850 [8.2] 27,900 [8.2] 27,900 [8.2] 28,000 [8.2] 27,850 [8.2] 27,850 [8.2] 27,800 [8.1] 28,250 [8.3] 27,900 [8.2] 27,800 [8.1] 27,800 [8.1] 27,900 [8.2] 27,900 [8.2] 28,300 [8.3] 12,300 [3.6] 12,000 [3.5] 12,150 [3.6] 12,350 [3.6] 12,450 [3.6] 12,450 [3.6] 12,200 [3.6] 12,200 [3.6] 12,200 [3.6] 12,750 [3.7] 12,200 [3.6] 12,200 [3.6] 11,200 [3.3] 12,200 [3.6] 12,200 [3.6] 12,600 [3.7] 12,100 [3.5] 12,600 [3.7] 12,150 [3.6] 11,500 [3.4] 11,200 [3.3] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,450 [3.6] 12,000 [3.5] 12,650 [3.7] 12,650 [3.7] 12,300 [3.6] 12,300 [3.6] 12,600 [3.7] 12,600 [3.7] 12,500 [3.7] 12,650 [3.7] 12,600 [3.7] 12,600 [3.7] 12,500 [3.7] 12,650 [3.7] 12,650 [3.7] 12,700 [3.7] 12,750 [3.7] 12,100 [3.5] 12,200 [3.6] 12,200 [3.6] 12,600 [3.7] 12,600 [3.7] 12,700 [3.7] 12.50 13.00 12.50 12.50 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 12.50 12.50 12.50 13.00 13.00 12.50 12.50 12.50 12.50 13.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 13.00 13.00 12.50 13.00 13.00 12.50 12.50 13.00 15.10 15.50 15.50 15.10 15.50 15.50 15.50 15.50 15.50 16.00 15.50 15.50 15.50 15.50 15.50 16.00 15.00 15.10 15.10 15.50 15.50 15.10 15.10 15.50 15.50 15.50 14.50 15.10 15.10 15.10 15.10 14.50 14.50 15.00 15.10 15.00 14.50 15.00 15.10 15.10 15.50 15.50 15.10 15.50 15.50 14.50 15.10 15.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 [ ] Designates Metric Conversions 21 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*3821(RGPE-10?BRM?) 41,000 [12.0] RCFL-H*3821(RGPT-05?BMK?) 39,500 [11.6] RCFL-H*3821(RGPT-07?AMK?) 39,500 [11.6] RCFL-H*3821(RGPT-07?BRQ?) 40,000 [11.7] RCFL-H*3821(RGPT-10?BRM?) 40,000 [11.7] RCFL-H*3821(RGRM-09?ZAJ?) 40,500 [11.9] RCFL-H*3821(RGRM-10?ZAJ?) 40,000 [11.7] RCFL-H*3821(RGTM-07?RBG?) 41,000 [12.0] RCFL-H*3821(RGTM-09?ZAJ?) 41,000 [12.0] RCFL-H*3821(RHWB-04WMX36A) 39,500 [11.6] RCFL-H*3821(RHWB-06WMX48A) 39,500 [11.6] RCFL-H*3821(ROCA-070E03) 39,500 [11.6] RCFL-H*3821(ROCA-070E04) 39,500 [11.6] RCFL-H*3821(ROLA-070E03) 39,500 [11.6] RCFL-H*3821(ROLA-070E04) 39,500 [11.6] RCFL-H*3821(ROLA-115E05) 40,000 [11.7] RCFL-H*3821+RXMD-C04 40,000 [11.7] RCFL-H*3824(RGFG-10?ZCM?) 39,500 [11.6] RCFL-H*3824(RGLT-07?BRQ?) 40,000 [11.7] RCFL-H*3824(RGLT-10?BRM?) 40,000 [11.7] RCFL-H*3824(RGLT-12?ARM?) 39,500 [11.6] RCFL-H*3824(RGPT-07?BRQ?) 40,500 [11.9] RCFL-H*3824(RGPT-10?BRM?) 40,000 [11.7] RCFL-H*3824(RGPT-12?ARM?) 40,000 [11.7] 042JEZ RCFL-H*3824(RHWB-08WPX60A) 40,500 [11.9] RCFL-H*3824(RHWB-10WRX60A) 41,000 [12.0] RCFL-H*3824(ROCA-070E03) 39,500 [11.6] RCFL-H*3824(ROCA-070E04) 39,500 [11.6] RCFL-H*3824(ROLA-070E03) 39,500 [11.6] RCFL-H*3824(ROLA-070E04) 39,500 [11.6] RCFL-H*3824(ROLA-115E05) 40,000 [11.7] RCFL-H*3824+RXMD-C04 40,000 [11.7] RCFL-H*4821(RGFE-09?ZCM?) 39,500 [11.6] RCFL-H*4821(RGFE-10?ZCM?) 40,000 [11.7] RCFL-H*4821(RGFG-09?ZCM?) 39,500 [11.6] RCFL-H*4821(RGFG-10?ZCM?) 39,500 [11.6] RCFL-H*4821(RGGE-06?MCK?) 39,500 [11.6] RCFL-H*4821(RGGE-07?MCK?) 39,500 [11.6] RCFL-H*4821(RGGE-09?ZCM?) 40,000 [11.7] RCFL-H*4821(RGGE-10?ZCM?) 39,500 [11.6] RCFL-H*4821(RGJF-06?MCK?) 39,500 [11.6] RCFL-H*4821(RGJF-07?MCK?) 39,500 [11.6] RCFL-H*4821(RGJF-09?ZCM?) 40,000 [11.7] RCFL-H*4821(RGJF-10?ZCM?) 39,500 [11.6] RCFL-H*4821(RGLE-07?AMK?) 39,500 [11.6] RCFL-H*4821(RGLE-10?BRM?) 40,500 [11.9] RCFL-H*4821(RGLT-07?AMK?) 40,000 [11.7] RCFL-H*4821(RGLT-07?BRQ?) 40,000 [11.7] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 22 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 28,250 [8.3] 27,450 [8.0] 27,450 [8.0] 27,800 [8.1] 27,800 [8.1] 27,900 [8.2] 27,050 [7.9] 28,650 [8.4] 28,500 [8.4] 27,300 [8.0] 27,300 [8.0] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,550 [8.1] 27,600 [8.1] 27,200 [8.0] 27,800 [8.1] 27,800 [8.1] 26,750 [7.8] 28,700 [8.4] 27,800 [8.1] 27,400 [8.0] 29,000 [8.5] 29,800 [8.7] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,550 [8.1] 27,600 [8.1] 27,150 [8.0] 27,900 [8.2] 27,400 [8.0] 27,200 [8.0] 27,200 [8.0] 27,200 [8.0] 27,850 [8.2] 27,150 [8.0] 27,200 [8.0] 27,200 [8.0] 27,850 [8.2] 27,100 [7.9] 27,150 [8.0] 29,150 [8.5] 27,900 [8.2] 27,800 [8.1] 12,750 [3.7] 12,050 [3.5] 12,050 [3.5] 12,200 [3.6] 12,200 [3.6] 12,600 [3.7] 12,950 [3.8] 12,350 [3.6] 12,500 [3.7] 12,200 [3.6] 12,200 [3.6] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,450 [3.6] 12,400 [3.6] 12,300 [3.6] 12,200 [3.6] 12,200 [3.6] 12,750 [3.7] 11,800 [3.5] 12,200 [3.6] 12,600 [3.7] 11,500 [3.4] 11,200 [3.3] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,450 [3.6] 12,400 [3.6] 12,350 [3.6] 12,100 [3.5] 12,100 [3.5] 12,300 [3.6] 12,300 [3.6] 12,300 [3.6] 12,150 [3.6] 12,350 [3.6] 12,300 [3.6] 12,300 [3.6] 12,150 [3.6] 12,400 [3.6] 12,350 [3.6] 11,350 [3.3] 12,100 [3.5] 12,200 [3.6] 13.00 12.00 12.00 13.00 13.00 12.50 12.50 12.50 13.00 12.50 12.50 12.50 12.50 12.50 12.50 13.00 12.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 12.50 12.50 13.00 12.00 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 13.00 SEER Sound Rating dB Indoor CFM [L/s] 15.50 14.50 14.50 15.50 15.50 15.00 15.00 15.10 15.50 15.10 15.10 15.10 15.10 15.50 15.50 15.50 14.50 15.10 15.50 15.50 16.00 15.50 15.50 16.00 15.50 15.50 15.10 15.10 15.50 15.50 15.50 14.50 15.10 15.10 15.10 15.10 14.50 14.50 15.50 15.10 14.50 14.50 15.50 15.10 15.10 15.50 15.10 15.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,225 [578] 1,225 [578] 1,250 [590] 1,250 [590] 1,225 [578] 1,225 [578] 1,150 [543] 1,275 [602] 1,250 [590] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,220 [576] 1,200 [566] 1,250 [590] 1,250 [590] 1,150 [543] 1,325 [625] 1,225 [578] 1,175 [554] 1,350 [637] 1,400 [661] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,220 [576] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,200 [566] 1,225 [578] 1,200 [566] 1,200 [566] 1,400 [661] 1,250 [590] 1,250 [590] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,250 [590] 1,200 [566] 1,225 [578] 1,225 [578] 1,225 [578] 1,225 [578] 1,250 [590] 1,250 [590] 1,225 [578] 1,225 [578] 1,150 [543] 1,225 [578] 1,125 [531] 1,250 [590] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,375 [649] 1,225 [578] 1,225 [578] 1,200 [566] 1,400 [661] 1,225 [578] 1,250 [590] 1,250 [590] 1,150 [543] 1,225 [578] 1,225 [578] 1,425 [672] 1,225 [578] 1,225 [578] 1,175 [554] 1,225 [578] 1,150 [543] 1,225 [578] 1,125 [531] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*4821(RGLT-10?BRM?) 40,000 [11.7] RCFL-H*4821(RGPE-05?BMK?) 39,500 [11.6] RCFL-H*4821(RGPE-07?AMK?) 40,000 [11.7] RCFL-H*4821(RGPE-07?BRQ?) 40,000 [11.7] RCFL-H*4821(RGPE-10?BRM?) 40,000 [11.7] RCFL-H*4821(RGPT-05?BMK?) 39,500 [11.6] RCFL-H*4821(RGPT-07?AMK?) 39,500 [11.6] RCFL-H*4821(RGPT-07?BRQ?) 40,000 [11.7] RCFL-H*4821(RGPT-10?BRM?) 40,000 [11.7] RCFL-H*4821(RGRM-09?ZAJ?) 40,000 [11.7] RCFL-H*4821(RGRM-10?ZAJ?) 39,500 [11.6] RCFL-H*4821(RGTM-06?MAE?) 39,500 [11.6] RCFL-H*4821(RGTM-07?RBG?) 39,500 [11.6] RCFL-H*4821(RGTM-09?ZAJ?) 40,000 [11.7] RCFL-H*4821(RHWB-04WMX36A) 39,500 [11.6] RCFL-H*4821(RHWB-06WMX48A) 39,500 [11.6] RCFL-H*4821(ROCA-070E03) 39,500 [11.6] RCFL-H*4821(ROCA-070E04) 39,500 [11.6] RCFL-H*4821(ROLA-070E03) 39,500 [11.6] RCFL-H*4821(ROLA-070E04) 39,500 [11.6] RCFL-H*4821(ROLA-115E05) 40,000 [11.7] RCFL-H*4824(RGFE-09?ZCM?) 39,500 [11.6] RCFL-H*4824(RGFE-10?ZCM?) 40,000 [11.7] RCFL-H*4824(RGFE-12?RCM?) 40,000 [11.7] 042JEZ RCFL-H*4824(RGFG-09?ZCM?) 39,500 [11.6] RCFL-H*4824(RGFG-10?ZCM?) 39,500 [11.6] RCFL-H*4824(RGFG-12?RCM?) 40,000 [11.7] RCFL-H*4824(RGGE-09?ZCM?) 40,000 [11.7] RCFL-H*4824(RGGE-10?ZCM?) 39,500 [11.6] RCFL-H*4824(RGGE-12?RCM?) 40,500 [11.9] RCFL-H*4824(RGJF-09?ZCM?) 40,000 [11.7] RCFL-H*4824(RGJF-10?ZCM?) 40,000 [11.7] RCFL-H*4824(RGJF-12?RCM?) 40,000 [11.7] RCFL-H*4824(RGLE-10?BRM?) 40,500 [11.9] RCFL-H*4824(RGLE-12?ARM?) 40,000 [11.7] RCFL-H*4824(RGLT-07?BRQ?) 40,000 [11.7] RCFL-H*4824(RGLT-10?BRM?) 40,000 [11.7] RCFL-H*4824(RGLT-12?ARM?) 39,500 [11.6] RCFL-H*4824(RGPE-07?BRQ?) 40,000 [11.7] RCFL-H*4824(RGPE-10?BRM?) 40,000 [11.7] RCFL-H*4824(RGPE-12?ARM?) 41,000 [12.0] RCFL-H*4824(RGPT-07?BRQ?) 40,000 [11.7] RCFL-H*4824(RGPT-10?BRM?) 40,000 [11.7] RCFL-H*4824(RGPT-12?ARM?) 40,000 [11.7] RCFL-H*4824(RGRM-09?ZAJ?) 40,000 [11.7] RCFL-H*4824(RGRM-10?ZAJ?) 39,500 [11.6] RCFL-H*4824(RGRM-12?RAJ?) 40,000 [11.7] RCFL-H*4824(RGTM-07?RBG?) 39,500 [11.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 27,800 [8.1] 27,200 [8.0] 27,900 [8.2] 27,800 [8.1] 27,800 [8.1] 27,450 [8.0] 27,450 [8.0] 27,800 [8.1] 27,800 [8.1] 27,900 [8.2] 26,900 [7.9] 27,500 [8.1] 26,700 [7.8] 27,850 [8.2] 27,300 [8.0] 27,300 [8.0] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,550 [8.1] 27,150 [8.0] 27,900 [8.2] 27,850 [8.2] 27,400 [8.0] 27,200 [8.0] 28,000 [8.2] 27,850 [8.2] 27,150 [8.0] 29,050 [8.5] 27,850 [8.2] 27,850 [8.2] 27,550 [8.1] 29,150 [8.5] 27,800 [8.1] 27,800 [8.1] 27,800 [8.1] 26,750 [7.8] 27,800 [8.1] 27,800 [8.1] 29,800 [8.7] 27,800 [8.1] 27,800 [8.1] 27,400 [8.0] 27,900 [8.2] 26,900 [7.9] 27,850 [8.2] 26,700 [7.8] 12,200 [3.6] 12,300 [3.6] 12,100 [3.5] 12,200 [3.6] 12,200 [3.6] 12,050 [3.5] 12,050 [3.5] 12,200 [3.6] 12,200 [3.6] 12,100 [3.5] 12,600 [3.7] 12,000 [3.5] 12,800 [3.8] 12,150 [3.6] 12,200 [3.6] 12,200 [3.6] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,450 [3.6] 12,350 [3.6] 12,100 [3.5] 12,150 [3.6] 12,100 [3.5] 12,300 [3.6] 12,000 [3.5] 12,150 [3.6] 12,350 [3.6] 11,450 [3.4] 12,150 [3.6] 12,150 [3.6] 12,450 [3.6] 11,350 [3.3] 12,200 [3.6] 12,200 [3.6] 12,200 [3.6] 12,750 [3.7] 12,200 [3.6] 12,200 [3.6] 11,200 [3.3] 12,200 [3.6] 12,200 [3.6] 12,600 [3.7] 12,100 [3.5] 12,600 [3.7] 12,150 [3.6] 12,800 [3.8] 13.00 12.00 12.50 13.00 13.00 12.00 12.00 13.00 13.00 12.50 12.50 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 13.00 12.50 12.50 12.50 12.50 12.50 13.00 12.50 12.50 12.50 12.50 12.50 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 12.50 12.50 12.50 12.50 15.50 14.50 15.10 15.50 15.50 14.50 14.50 15.50 15.50 15.10 15.10 14.50 15.50 15.10 15.10 15.10 15.10 15.10 15.50 15.50 15.50 15.10 15.10 15.50 15.10 15.10 15.50 15.50 15.10 15.00 15.50 15.50 15.50 15.50 15.50 15.50 15.50 16.00 15.50 15.50 15.50 15.50 15.50 16.00 15.00 15.10 15.10 15.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 [ ] Designates Metric Conversions 23 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*4824(RGTM-09?ZAJ?) 40,000 [11.7] RCFL-H*4824(RGTM-10?RBJ?) 39,500 [11.6] RCFL-H*4824(RHWB-08WPX60A) 40,500 [11.9] RCFL-H*4824(RHWB-10WPX60A) 41,000 [12.0] RCFL-H*4824(ROCA-070E03) 39,500 [11.6] RCFL-H*4824(ROCA-070E04) 39,500 [11.6] RCFL-H*4824(ROLA-070E03) 39,500 [11.6] RCFL-H*4824(ROLA-070E04) 39,500 [11.6] RCFL-H*4824(ROLA-115E05) 40,000 [11.7] RCFL-H*4824+RXMD-C04 39,500 [11.6] RCFN-H*4824(RGFE-09?ZCM?) 43,500 [12.7] RCFN-H*4824(RGFE-10?ZCM?) 42,500 [12.5] RCFN-H*4824(RGFE-12?RCM?) 43,000 [12.6] RCFN-H*4824(RGFG-09?ZCM?) 44,000 [12.9] RCFN-H*4824(RGFG-10?ZCM?) 44,000 [12.9] RCFN-H*4824(RGFG-12?RCM?) 44,500 [13.0] RCFN-H*4824(RGGE-09?ZCM?) 43,000 [12.6] RCFN-H*4824(RGGE-10?ZCM?) 43,500 [12.7] RCFN-H*4824(RGGE-12?RCM?) 43,500 [12.7] RCFN-H*4824(RGJF-09?ZCM?) 43,000 [12.6] RCFN-H*4824(RGJF-10?ZCM?) 43,500 [12.7] RCFN-H*4824(RGJF-12?RCM?) 43,500 [12.7] RCFN-H*4824(RGLE-07?BRQ?) 43,000 [12.6] RCFN-H*4824(RGLE-10?BRM?) 44,000 [12.9] 042JEZ RCFN-H*4824(RGLE-12?ARM?) 43,000 [12.6] RCFN-H*4824(RGLT-07?BRQ?) 43,000 [12.6] RCFN-H*4824(RGLT-10?BRM?) 43,000 [12.6] RCFN-H*4824(RGLT-12?ARM?) 44,000 [12.9] RCFN-H*4824(RGPE-07?BRQ?) 43,000 [12.6] RCFN-H*4824(RGPE-10?BRM?) 43,000 [12.6] RCFN-H*4824(RGPE-12?ARM?) 43,500 [12.7] RCFN-H*4824(RGPT-07?BRQ?) 43,500 [12.7] RCFN-H*4824(RGPT-12?ARM?) 44,000 [12.9] RCFN-H*4824(RGRM-09?ZAJ?) 42,500 [12.5] RCFN-H*4824(RGRM-12?RAJ?) 42,500 [12.5] RCFN-H*4824(RHWB-08WRX60A) 44,500 [13.0] RCFN-H*4824(RHWB-10WRX60A) 44,500 [13.0] RCFN-H*4824(ROLA-070E04) 43,500 [12.7] RCFN-H*4824(ROLA-115E05) 43,500 [12.7] RCFN-H*4824+RXMD-C04 42,000 [12.3] RBHP-24(RCHL-48A1) 39,500 [11.6] RCQD-4821(RGFE-06?MCK?) 39,500 [11.6] RCQD-4821(RGFE-09?ZCM?) 40,500 [11.9] RCQD-4821(RGFE-10?ZCM?) 40,500 [11.9] RCQD-4821(RGFG-09?ZCM?) 39,500 [11.6] RCQD-4821(RGFG-10?ZCM?) 39,500 [11.6] RCQD-4821(RGJF-06?MCK?) 40,000 [11.7] RCQD-4821(RGJF-07?MCK?) 39,500 [11.6] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 24 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 27,850 [8.2] 26,700 [7.8] 29,000 [8.5] 29,800 [8.7] 27,150 [8.0] 27,150 [8.0] 26,950 [7.9] 26,950 [7.9] 27,550 [8.1] 27,500 [8.1] 32,500 [9.5] 30,500 [8.9] 30,950 [9.1] 34,000 [10.0] 34,050 [10.0] 34,800 [10.2] 30,950 [9.1] 32,500 [9.5] 32,500 [9.5] 30,950 [9.1] 32,500 [9.5] 32,500 [9.5] 30,900 [9.1] 32,950 [9.7] 32,300 [9.5] 31,050 [9.1] 31,050 [9.1] 32,950 [9.7] 30,900 [9.1] 30,900 [9.1] 32,500 [9.5] 31,950 [9.4] 32,950 [9.7] 30,100 [8.8] 30,050 [8.8] 34,400 [10.1] 34,700 [10.2] 32,500 [9.5] 32,500 [9.5] 29,800 [8.7] 27,200 [8.0] 27,400 [8.0] 29,450 [8.6] 29,600 [8.7] 27,400 [8.0] 27,400 [8.0] 27,850 [8.2] 27,350 [8.0] 12,150 [3.6] 12,800 [3.8] 11,500 [3.4] 11,200 [3.3] 12,350 [3.6] 12,350 [3.6] 12,550 [3.7] 12,550 [3.7] 12,450 [3.6] 12,000 [3.5] 11,000 [3.2] 12,000 [3.5] 12,050 [3.5] 10,000 [2.9] 9,950 [2.9] 9,700 [2.8] 12,050 [3.5] 11,000 [3.2] 11,000 [3.2] 12,050 [3.5] 11,000 [3.2] 11,000 [3.2] 12,100 [3.5] 11,050 [3.2] 10,700 [3.1] 11,950 [3.5] 11,950 [3.5] 11,050 [3.2] 12,100 [3.5] 12,100 [3.5] 11,000 [3.2] 11,550 [3.4] 11,050 [3.2] 12,400 [3.6] 12,450 [3.6] 10,100 [3.0] 9,800 [2.9] 11,000 [3.2] 11,000 [3.2] 12,200 [3.6] 12,300 [3.6] 12,100 [3.5] 11,050 [3.2] 10,900 [3.2] 12,100 [3.5] 12,100 [3.5] 12,150 [3.6] 12,150 [3.6] 12.50 13.00 13.00 13.00 12.50 12.50 12.50 12.50 13.00 12.00 12.50 13.00 13.00 13.00 12.50 13.00 13.00 12.50 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 11.50 11.50 12.00 12.50 12.00 12.00 12.00 SEER Sound Rating dB Indoor CFM [L/s] 15.10 15.50 15.50 15.50 15.10 15.10 15.50 15.50 15.50 14.50 15.00 15.50 16.00 15.50 15.10 15.50 16.00 15.00 15.50 16.00 15.00 15.50 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 15.50 15.50 16.00 16.00 15.50 15.50 15.00 15.00 14.00 14.00 14.00 15.00 14.50 14.50 14.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,250 [590] 1,125 [531] 1,350 [637] 1,400 [661] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,250 [590] 1,200 [566] 1,225 [578] 1,225 [578] 1,400 [661] 1,400 [661] 1,450 [684] 1,225 [578] 1,200 [566] 1,375 [649] 1,225 [578] 1,200 [566] 1,375 [649] 1,225 [578] 1,400 [661] 1,225 [578] 1,250 [590] 1,250 [590] 1,400 [661] 1,225 [578] 1,225 [578] 1,425 [672] 1,325 [625] 1,375 [649] 1,225 [578] 1,225 [578] 1,350 [637] 1,400 [661] 1,375 [649] 1,400 [661] 1,200 [566] 1,400 [661] 1,200 [566] 1,400 [661] 1,425 [672] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] Air Performance Data RAPM- JEZ Series SEER Sound Rating dB Indoor CFM [L/s] 15.00 15.00 14.50 14.50 15.10 15.50 14.00 14.50 15.00 15.50 14.00 14.00 15.10 15.10 14.50 14.50 15.10 15.10 15.10 14.00 15.00 14.50 15.00 15.10 15.10 15.50 15.00 14.50 15.50 15.50 15.50 15.50 15.50 15.50 15.50 14.00 14.00 14.50 15.50 15.00 15.00 15.10 15.10 15.50 14.00 16.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,225 [578] 1,225 [578] 1,250 [590] 1,250 [590] 1,250 [590] 1,250 [590] 1,225 [578] 1,150 [543] 1,200 [566] 1,200 [566] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,255 [592] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,200 [566] 1,225 [578] 1,225 [578] 1,400 [661] 1,200 [566] 1,225 [578] 1,225 [578] 1,200 [566] 1,275 [602] 1,275 [602] 1,225 [578] 1,225 [578] 1,150 [543] 1,225 [578] 1,400 [661] 1,200 [566] 1,200 [566] 1,175 [554] 1,175 [554] 1,200 [566] 1,255 [592] 1,200 [566] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCQD-4821(RGJF-09?ZCM?) 40,000 [11.7] RCQD-4821(RGJF-10?ZCM?) 40,000 [11.7] RCQD-4821(RGPE-05?BMK?) 39,500 [11.6] RCQD-4821(RGPE-07?AMK?) 40,000 [11.7] RCQD-4821(RGPE-07?BRQ?) 40,500 [11.9] RCQD-4821(RGPE-10?BRM?) 40,500 [11.9] RCQD-4821(RGPT-05?BMK?) 40,000 [11.7] RCQD-4821(RGPT-07?AMK?) 40,000 [11.7] RCQD-4821(RGPT-07?BRQ?) 40,500 [11.9] RCQD-4821(RGPT-10?BRM?) 40,500 [11.9] RCQD-4821(RGRM-09?ZAJ?) 40,000 [11.7] RCQD-4821(RGRM-10?ZAJ?) 39,500 [11.6] RCQD-4821(RHWB-04WMX36A) 39,500 [11.6] RCQD-4821(RHWB-06WMX48A) 39,500 [11.6] RCQD-4821(ROCA-070E03) 40,000 [11.7] RCQD-4821(ROCA-070E04) 40,000 [11.7] RCQD-4821(ROLA-070E03) 40,000 [11.7] RCQD-4821(ROLA-070E04) 40,000 [11.7] RCQD-4821(ROLA-115E05) 40,000 [11.7] RCQD-4821+RXMD-C04 39,500 [11.6] RCQD-4824(RGFE-09?ZCM?) 40,000 [11.7] RCQD-4824(RGFE-10?ZCM?) 40,000 [11.7] RCQD-4824(RGFE-12?RCM?) 40,500 [11.9] 042JEZ RCQD-4824(RGFG-09?ZCM?) 39,500 [11.6] RCQD-4824(RGFG-10?ZCM?) 39,500 [11.6] RCQD-4824(RGFG-12?RCM?) 40,000 [11.7] RCQD-4824(RGJF-09?ZCM?) 40,000 [11.7] RCQD-4824(RGJF-10?ZCM?) 40,500 [11.9] RCQD-4824(RGJF-12?RCM?) 40,000 [11.7] RCQD-4824(RGPE-07?BRQ?) 40,500 [11.9] RCQD-4824(RGPE-10?BRM?) 40,500 [11.9] RCQD-4824(RGPE-12?ARM?) 40,500 [11.9] RCQD-4824(RGPT-07?BRQ?) 40,500 [11.9] RCQD-4824(RGPT-10?BRM?) 40,500 [11.9] RCQD-4824(RGPT-12?ARM?) 40,500 [11.9] RCQD-4824(RGRM-09?ZAJ?) 39,500 [11.6] RCQD-4824(RGRM-10?ZAJ?) 39,500 [11.6] RCQD-4824(RGRM-12?RAJ?) 40,000 [11.7] RCQD-4824(RHWB-08WRX60A) 41,000 [12.0] RCQD-4824(ROCA-070E03) 40,000 [11.7] RCQD-4824(ROCA-070E04) 40,000 [11.7] RCQD-4824(ROLA-070E03) 40,000 [11.7] RCQD-4824(ROLA-070E04) 40,000 [11.7] RCQD-4824(ROLA-115E05) 40,000 [11.7] RCQD-4824+RXMD-C04 39,500 [11.6] RHKL-HM3821(RCSL-H*3821) 41,000 [12.0] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] 27,900 [8.2] 27,750 [8.1] 27,350 [8.0] 27,950 [8.2] 28,350 [8.3] 28,350 [8.3] 28,150 [8.2] 28,100 [8.2] 28,500 [8.4] 28,500 [8.4] 30,200 [8.8] 29,250 [8.6] 27,600 [8.1] 27,600 [8.1] 27,800 [8.1] 27,800 [8.1] 27,600 [8.1] 27,600 [8.1] 27,700 [8.1] 27,800 [8.1] 27,750 [8.1] 27,900 [8.2] 28,350 [8.3] 27,400 [8.0] 27,400 [8.0] 28,100 [8.2] 27,850 [8.2] 29,400 [8.6] 27,700 [8.1] 28,300 [8.3] 28,300 [8.3] 28,150 [8.2] 28,500 [8.4] 28,450 [8.3] 28,300 [8.3] 29,900 [8.8] 29,450 [8.6] 30,350 [8.9] 30,100 [8.8] 27,750 [8.1] 27,750 [8.1] 27,600 [8.1] 27,600 [8.1] 27,700 [8.1] 27,800 [8.1] 28,250 [8.3] 12,100 [3.5] 12,250 [3.6] 12,150 [3.6] 12,050 [3.5] 12,150 [3.6] 12,150 [3.6] 11,850 [3.5] 11,900 [3.5] 12,000 [3.5] 12,000 [3.5] 9,800 [2.9] 10,250 [3.0] 11,900 [3.5] 11,900 [3.5] 12,200 [3.6] 12,200 [3.6] 12,400 [3.6] 12,400 [3.6] 12,300 [3.6] 11,700 [3.4] 12,250 [3.6] 12,100 [3.5] 12,150 [3.6] 12,100 [3.5] 12,100 [3.5] 11,900 [3.5] 12,150 [3.6] 11,100 [3.3] 12,300 [3.6] 12,200 [3.6] 12,200 [3.6] 12,350 [3.6] 12,000 [3.5] 12,050 [3.5] 12,200 [3.6] 9,600 [2.8] 10,050 [2.9] 9,650 [2.8] 10,900 [3.2] 12,250 [3.6] 12,250 [3.6] 12,400 [3.6] 12,400 [3.6] 12,300 [3.6] 11,700 [3.4] 12,750 [3.7] EER 12.50 12.50 12.00 12.00 12.50 12.50 12.00 12.00 13.00 13.00 11.50 11.50 12.50 12.50 12.00 12.00 12.50 12.50 12.50 11.50 12.50 12.00 12.50 12.50 12.50 13.00 12.50 12.00 12.50 12.50 12.50 13.00 13.00 13.00 13.00 11.50 11.50 12.00 13.00 12.50 12.50 12.50 12.50 13.00 11.50 13.00 [ ] Designates Metric Conversions 25 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 042JEZ Indoor Coil and/or Air Handler RHLL-HM3821(RCSL-H*3821) RHKL-HM4821(RCSL-H*4821) RHLL-HM4821(RCSL-H*4821) RHSL-HM4221(RCSL-H*4821) RHPN-HM3624(RCSN-H*3624) Total Capacity BTU/H [kW] 41,000 [12.0] 41,000 [12.0] 41,000 [12.0] 40,000 [11.7] 43,000 [12.6] 47,500 [13.9] RCFL-H*4821+RXMD-C04 ➀ RCFL-A*4821(RGFE-09?ZCM?) 47,000 [13.8] RCFL-A*4821(RGFG-09?ZCM?) 47,000 [13.8] RCFL-A*4821(RGGE-09?ZCM?) 47,000 [13.8] RCFL-A*4821(RGGE-10?ZCM?) 47,000 [13.8] RCFL-A*4821(RGLE-10?BRM?) 47,500 [13.9] RCFL-A*4821(RGLT-07?AMK?) 46,500 [13.6] RCFL-A*4821(RGLT-07?BRQ?) 47,500 [13.9] RCFL-A*4821(RGLT-10?BRM?) 47,500 [13.9] RCFL-A*4821(RGPE-07?BRQ?) 47,500 [13.9] RCFL-A*4821(RGPE-10?BRM?) 47,500 [13.9] RCFL-A*4821(RGPT-07?AMK?) 46,500 [13.6] RCFL-A*4821(RGPT-07?BRQ?) 47,500 [13.9] RCFL-A*4821(RGPT-10?BRM?) 47,500 [13.9] RCFL-A*4821(RGTM-07?RBG?) 47,500 [13.9] RCFL-A*4821(RGTM-09?ZAJ?) 47,000 [13.8] RCFL-A*4821(ROLA-070E04) 47,000 [13.8] RCFL-A*4821(ROLA-115E05) 47,000 [13.8] RCFL-A*4821+RXMD-C04 47,500 [13.9] RCFL-A*4824(RGFE-09?ZCM?) 47,000 [13.8] RCFL-A*4824(RGFE-12?RCM?) 47,500 [13.9] RCFL-A*4824(RGFG-10?ZCM?) 47,000 [13.8] 048JEZ RCFL-A*4824(RGFG-12?RCM?) 47,000 [13.8] RCFL-A*4824(RGGE-09?ZCM?) 47,000 [13.8] RCFL-A*4824(RGGE-12?RCM?) 47,000 [13.8] RCFL-A*4824(RGLE-10?BRM?) 47,500 [13.9] RCFL-A*4824(RGLE-12?ARM?) 47,500 [13.9] RCFL-A*4824(RGLT-07?BRQ?) 47,500 [13.9] RCFL-A*4824(RGLT-10?BRM?) 47,500 [13.9] RCFL-A*4824(RGLT-12?ARM?) 47,500 [13.9] RCFL-A*4824(RGPE-07?BRQ?) 47,500 [13.9] RCFL-A*4824(RGPE-10?BRM?) 47,500 [13.9] RCFL-A*4824(RGPE-12?ARM?) 47,500 [13.9] RCFL-A*4824(RGPT-07?BRQ?) 48,500 [14.2] RCFL-A*4824(RGPT-10?BRM?) 47,500 [13.9] RCFL-A*4824(RGPT-12?ARM?) 47,500 [13.9] RCFL-A*4824(RGTM-07?RBG?) 47,500 [13.9] RCFL-A*4824(RGTM-09?ZAJ?) 47,000 [13.8] RCFL-A*4824(RGTM-10?RBJ?) 47,500 [13.9] RCFL-A*4824(RHWB-08WRX60A) 47,500 [13.9] RCFL-A*4824(RHWB-10WRX60A) 48,000 [14.1] RCFL-A*4824(ROLA-070E04) 47,000 [13.8] RCFL-A*4824(ROLA-115E05) 47,500 [13.9] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 26 Net Sensible BTU/H [kW] SEER Sound Rating dB Indoor CFM [L/s] 13.00 13.00 13.00 12.00 13.00 16.00 15.50 15.50 14.50 16.00 76 76 76 76 76 1,220 [576] 1,400 [661] 1,400 [661] 1,350 [637] 1,200 [566] 12.00 12.00 12.00 12.50 12.00 12.50 12.00 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.00 12.50 12.00 12.50 12.50 12.50 12.50 12.50 13.00 12.50 12.50 12.50 13.00 12.50 13.00 12.50 12.50 12.50 12.50 13.00 12.50 12.00 14.50 14.50 14.50 14.50 14.50 15.10 14.50 15.10 15.10 15.10 15.10 14.50 15.00 15.50 14.50 14.50 15.10 15.10 14.50 14.50 15.00 14.50 15.00 14.50 15.10 15.10 15.10 15.10 15.10 15.50 15.10 15.10 15.10 15.50 15.10 15.50 14.50 14.50 15.10 15.10 15.50 15.10 14.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,575 [743] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,325 [625] 1,425 [672] 1,400 [661] 1,400 [661] 1,400 [661] 1,325 [625] 1,425 [672] 1,425 [672] 1,475 [696] 1,400 [661] 1,375 [649] 1,400 [661] 1,575 [743] 1,400 [661] 1,450 [684] 1,400 [661] 1,450 [684] 1,400 [661] 1,375 [649] 1,400 [661] 1,425 [672] 1,425 [672] 1,400 [661] 1,350 [637] 1,400 [661] 1,400 [661] 1,425 [672] 1,550 [731] 1,400 [661] 1,350 [637] 1,475 [696] 1,400 [661] 1,425 [672] 1,450 [684] 1,475 [696] 1,375 [649] 1,500 [708] Net Latent BTU/H [kW] EER [8.4] [8.7] [8.7] [8.4] [8.9] 12,200 [3.6] 11,400 [3.3] 11,400 [3.3] 11,450 [3.4] 12,550 [3.7] 33,350 [9.8] 31,650 [9.3] 31,600 [9.3] 31,600 [9.3] 31,650 [9.3] 32,000 [9.4] 30,650 [9.0] 32,200 [9.4] 32,050 [9.4] 32,050 [9.4] 32,050 [9.4] 30,700 [9.0] 32,150 [9.4] 32,150 [9.4] 32,600 [9.6] 31,600 [9.3] 31,400 [9.2] 31,550 [9.2] 33,350 [9.8] 31,650 [9.3] 32,400 [9.5] 31,600 [9.3] 32,200 [9.4] 31,600 [9.3] 31,350 [9.2] 32,000 [9.4] 32,150 [9.4] 32,200 [9.4] 32,050 [9.4] 31,650 [9.3] 32,050 [9.4] 32,050 [9.4] 32,150 [9.4] 34,100 [10.0] 32,000 [9.4] 31,650 [9.3] 32,600 [9.6] 31,600 [9.3] 32,200 [9.4] 32,500 [9.5] 33,200 [9.7] 31,400 [9.2] 32,800 [9.6] 14,150 [4.1] 15,350 [4.5] 15,400 [4.5] 15,400 [4.5] 15,350 [4.5] 15,500 [4.5] 15,850 [4.6] 15,300 [4.5] 15,450 [4.5] 15,450 [4.5] 15,450 [4.5] 15,800 [4.6] 15,350 [4.5] 15,350 [4.5] 14,900 [4.4] 15,400 [4.5] 15,600 [4.6] 15,450 [4.5] 14,150 [4.1] 15,350 [4.5] 15,100 [4.4] 15,400 [4.5] 14,800 [4.3] 15,400 [4.5] 15,650 [4.6] 15,500 [4.5] 15,350 [4.5] 15,300 [4.5] 15,450 [4.5] 15,850 [4.6] 15,450 [4.5] 15,450 [4.5] 15,350 [4.5] 14,400 [4.2] 15,500 [4.5] 15,850 [4.6] 14,900 [4.4] 15,400 [4.5] 15,300 [4.5] 15,000 [4.4] 14,800 [4.3] 15,600 [4.6] 14,700 [4.3] 28,800 29,600 29,600 28,550 30,450 Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] 1,575 [743] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,325 [625] 1,425 [672] 1,400 [661] 1,400 [661] 1,400 [661] 1,325 [625] 1,425 [672] 1,425 [672] 1,400 [661] 1,475 [696] 1,400 [661] 1,375 [649] 1,400 [661] 1,400 [661] 1,450 [684] 1,450 [684] 1,400 [661] 1,400 [661] 1,375 [649] 1,400 [661] 1,400 [661] 1,375 [649] 1,400 [661] 1,425 [672] 1,425 [672] 1,400 [661] 1,350 [637] 1,400 [661] 1,400 [661] 1,425 [672] 1,550 [731] 1,400 [661] 1,350 [637] 1,425 [672] 1,475 [696] 1,400 [661] 1,425 [672] 1,450 [684] 1,475 [696] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-A*4824+RXMD-C04 47,500 [13.9] RCFL-H*4821(RGFE-09?ZCM?) 47,000 [13.8] RCFL-H*4821(RGFG-09?ZCM?) 47,000 [13.8] RCFL-H*4821(RGFG-10?ZCM?) 47,000 [13.8] RCFL-H*4821(RGGE-09?ZCM?) 47,000 [13.8] RCFL-H*4821(RGGE-10?ZCM?) 47,000 [13.8] RCFL-H*4821(RGJF-09?ZCM?) 47,000 [13.8] RCFL-H*4821(RGJF-10?ZCM?) 47,000 [13.8] RCFL-H*4821(RGLE-10?BRM?) 47,500 [13.9] RCFL-H*4821(RGLT-07?AMK?) 46,500 [13.6] RCFL-H*4821(RGLT-07?BRQ?) 47,500 [13.9] RCFL-H*4821(RGLT-10?BRM?) 47,500 [13.9] RCFL-H*4821(RGPE-07?BRQ?) 47,500 [13.9] RCFL-H*4821(RGPE-10?BRM?) 47,500 [13.9] RCFL-H*4821(RGPT-07?AMK?) 46,500 [13.6] RCFL-H*4821(RGPT-07?BRQ?) 47,500 [13.9] RCFL-H*4821(RGPT-10?BRM?) 47,500 [13.9] RCFL-H*4821(RGRM-09?ZAJ?) 47,000 [13.8] RCFL-H*4821(RGTM-07?RBG?) 47,500 [13.9] RCFL-H*4821(RGTM-09?ZAJ?) 47,000 [13.8] RCFL-H*4821(ROLA-070E04) 47,000 [13.8] RCFL-H*4821(ROLA-115E05) 47,000 [13.8] RCFL-H*4824(RGFE-09?ZCM?) 47,000 [13.8] RCFL-H*4824(RGFE-12?RCM?) 47,500 [13.9] 048JEZ RCFL-H*4824(RGFG-12?RCM?) 47,000 [13.8] RCFL-H*4824(RGGE-09?ZCM?) 47,000 [13.8] RCFL-H*4824(RGGE-10?ZCM?) 47,000 [13.8] RCFL-H*4824(RGGE-12?RCM?) 47,000 [13.8] RCFL-H*4824(RGJF-09?ZCM?) 47,000 [13.8] RCFL-H*4824(RGJF-10?ZCM?) 47,000 [13.8] RCFL-H*4824(RGJF-12?RCM?) 47,000 [13.8] RCFL-H*4824(RGLE-10?BRM?) 47,500 [13.9] RCFL-H*4824(RGLE-12?ARM?) 47,500 [13.9] RCFL-H*4824(RGLT-07?BRQ?) 47,500 [13.9] RCFL-H*4824(RGLT-10?BRM?) 47,500 [13.9] RCFL-H*4824(RGLT-12?ARM?) 47,500 [13.9] RCFL-H*4824(RGPE-07?BRQ?) 47,500 [13.9] RCFL-H*4824(RGPE-10?BRM?) 47,500 [13.9] RCFL-H*4824(RGPE-12?ARM?) 47,500 [13.9] RCFL-H*4824(RGPT-07?BRQ?) 48,500 [14.2] RCFL-H*4824(RGPT-10?BRM?) 47,500 [13.9] RCFL-H*4824(RGPT-12?ARM?) 47,500 [13.9] RCFL-H*4824(RGRM-12?RAJ?) 47,000 [13.8] RCFL-H*4824(RGTM-07?RBG?) 47,500 [13.9] RCFL-H*4824(RGTM-09?ZAJ?) 47,000 [13.8] RCFL-H*4824(RGTM-10?RBJ?) 47,500 [13.9] RCFL-H*4824(RHWB-08WRX60A) 47,500 [13.9] RCFL-H*4824(RHWB-10WRX60A) 48,000 [14.1] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 33,350 [9.8] 31,650 [9.3] 31,600 [9.3] 31,600 [9.3] 31,600 [9.3] 31,650 [9.3] 31,600 [9.3] 31,650 [9.3] 32,000 [9.4] 30,650 [9.0] 32,200 [9.4] 32,050 [9.4] 32,050 [9.4] 32,050 [9.4] 30,700 [9.0] 32,150 [9.4] 32,150 [9.4] 31,700 [9.3] 32,600 [9.6] 31,600 [9.3] 31,400 [9.2] 31,550 [9.2] 31,650 [9.3] 32,400 [9.5] 32,200 [9.4] 31,600 [9.3] 31,650 [9.3] 31,350 [9.2] 31,600 [9.3] 31,650 [9.3] 31,350 [9.2] 32,000 [9.4] 32,150 [9.4] 32,200 [9.4] 32,050 [9.4] 31,650 [9.3] 32,050 [9.4] 32,050 [9.4] 32,150 [9.4] 34,100 [10.0] 32,000 [9.4] 31,650 [9.3] 31,750 [9.3] 32,600 [9.6] 31,600 [9.3] 32,200 [9.4] 32,500 [9.5] 33,200 [9.7] 14,150 [4.1] 15,350 [4.5] 15,400 [4.5] 15,400 [4.5] 15,400 [4.5] 15,350 [4.5] 15,400 [4.5] 15,350 [4.5] 15,500 [4.5] 15,850 [4.6] 15,300 [4.5] 15,450 [4.5] 15,450 [4.5] 15,450 [4.5] 15,800 [4.6] 15,350 [4.5] 15,350 [4.5] 15,300 [4.5] 14,900 [4.4] 15,400 [4.5] 15,600 [4.6] 15,450 [4.5] 15,350 [4.5] 15,100 [4.4] 14,800 [4.3] 15,400 [4.5] 15,350 [4.5] 15,650 [4.6] 15,400 [4.5] 15,350 [4.5] 15,650 [4.6] 15,500 [4.5] 15,350 [4.5] 15,300 [4.5] 15,450 [4.5] 15,850 [4.6] 15,450 [4.5] 15,450 [4.5] 15,350 [4.5] 14,400 [4.2] 15,500 [4.5] 15,850 [4.6] 15,250 [4.5] 14,900 [4.4] 15,400 [4.5] 15,300 [4.5] 15,000 [4.4] 14,800 [4.3] 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.00 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.00 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.00 12.00 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 13.00 12.50 12.50 12.50 13.00 12.50 13.00 12.00 12.50 12.50 12.50 12.50 13.00 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 15.10 14.50 15.10 15.10 15.10 15.10 14.50 15.00 15.50 14.50 14.50 14.50 15.10 15.10 14.50 15.00 15.00 14.50 14.50 15.10 14.50 14.50 15.10 15.10 15.10 15.10 15.10 15.50 15.10 15.10 15.10 15.50 15.10 15.50 14.50 14.50 14.50 15.10 15.10 15.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 [ ] Designates Metric Conversions 27 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] RCFL-H*4824(ROLA-070E04) 47,000 [13.8] RCFL-H*4824(ROLA-115E05) 47,500 [13.9] RCFL-H*4824+RXMD-C04 47,500 [13.9] RCFN-H*4824(RGFE-12?RCM?) 50,500 [14.8] RCFN-H*4824(RGFG-09?ZCM?) 49,500 [14.5] RCFN-H*4824(RGFG-10?ZCM?) 49,500 [14.5] RCFN-H*4824(RGFG-12?RCM?) 50,000 [14.6] RCFN-H*4824(RGGE-12?RCM?) 51,500 [15.1] RCFN-H*4824(RGJF-12?RCM?) 51,500 [15.1] RCFN-H*4824(RGLE-07?BRQ?) 51,500 [15.1] RCFN-H*4824(RGLE-10?BRM?) 51,500 [15.1] RCFN-H*4824(RGLE-12?ARM?) 51,500 [15.1] RCFN-H*4824(RGLT-07?BRQ?) 50,000 [14.6] RCFN-H*4824(RGLT-10?BRM?) 50,000 [14.6] RCFN-H*4824(RGLT-12?ARM?) 51,000 [14.9] RCFN-H*4824(RGPE-07?BRQ?) 51,500 [15.1] RCFN-H*4824(RGPE-10?BRM?) 51,500 [15.1] RCFN-H*4824(RGPE-12?ARM?) 51,000 [14.9] RCFN-H*4824(RGPT-07?BRQ?) 50,500 [14.8] RCFN-H*4824(RGPT-10?BRM?) 50,000 [14.6] RCFN-H*4824(RGPT-12?ARM?) 51,000 [14.9] RCFN-H*4824(RHWB-08WRX60A) 50,500 [14.8] RCFN-H*4824(RHWB-10WRX60A) 50,500 [14.8] RCFN-H*4824(ROLA-115E05) 50,000 [14.6] 048JEZ RCFN-H*4824+RXMD-C04 51,000 [14.9] RBHP-24(RCHL-48A1) 47,000 [13.8] RCQD-4821(RGFE-09?ZCM?) 47,000 [13.8] RCQD-4821(RGFG-09?ZCM?) 47,500 [13.9] RCQD-4821(RGFG-10?ZCM?) 47,500 [13.9] RCQD-4821(RGJF-09?ZCM?) 47,500 [13.9] RCQD-4821(RGJF-10?ZCM?) 47,000 [13.8] RCQD-4821(RGPE-07?BRQ?) 47,500 [13.9] RCQD-4821(RGPE-10?BRM?) 48,000 [14.1] RCQD-4821(RGPT-07?BRQ?) 48,500 [14.2] RCQD-4821(RGPT-10?BRM?) 47,500 [13.9] RCQD-4821(RGRM-09?ZAJ?) 48,000 [14.1] RCQD-4821(ROLA-070E04) 47,500 [13.9] RCQD-4821+RXMD-C04 47,500 [13.9] RCQD-4824(RGFE-09?ZCM?) 47,000 [13.8] RCQD-4824(RGFE-10?ZCM?) 47,500 [13.9] RCQD-4824(RGFE-12?RCM?) 47,500 [13.9] RCQD-4824(RGFG-09?ZCM?) 47,500 [13.9] RCQD-4824(RGFG-10?ZCM?) 47,500 [13.9] RCQD-4824(RGFG-12?RCM?) 48,000 [14.1] RCQD-4824(RGJF-09?ZCM?) 47,500 [13.9] RCQD-4824(RGJF-10?ZCM?) 47,500 [13.9] RCQD-4824(RGJF-12?RCM?) 48,500 [14.2] RCQD-4824(RGPE-07?BRQ?) 48,500 [14.2] ➀ Highest sales volume tested combination required by D.O.E. test procedures. Rev. 6/14/12 [ ] Designates Metric Conversions 28 Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER 31,400 [9.2] 32,800 [9.6] 33,350 [9.8] 36,050 [10.6] 35,250 [10.3] 35,250 [10.3] 36,000 [10.5] 37,950 [11.1] 37,950 [11.1] 38,150 [11.2] 38,100 [11.2] 38,100 [11.2] 35,750 [10.5] 35,750 [10.5] 38,600 [11.3] 38,150 [11.2] 37,750 [11.1] 37,050 [10.9] 36,900 [10.8] 35,750 [10.5] 38,600 [11.3] 36,800 [10.8] 37,100 [10.9] 36,900 [10.8] 37,650 [11.0] 32,000 [9.4] 31,500 [9.2] 32,250 [9.4] 32,250 [9.4] 32,000 [9.4] 31,500 [9.2] 31,900 [9.3] 33,800 [9.9] 33,850 [9.9] 32,050 [9.4] 35,100 [10.3] 31,750 [9.3] 33,750 [9.9] 31,500 [9.2] 32,200 [9.4] 32,250 [9.4] 32,200 [9.4] 32,200 [9.4] 32,950 [9.7] 31,950 [9.4] 32,000 [9.4] 34,250 [10.0] 34,250 [10.0] 15,600 [4.6] 14,700 [4.3] 14,150 [4.1] 14,450 [4.2] 14,250 [4.2] 14,250 [4.2] 14,000 [4.1] 13,550 [4.0] 13,550 [4.0] 13,350 [3.9] 13,400 [3.9] 13,400 [3.9] 14,250 [4.2] 14,250 [4.2] 12,400 [3.6] 13,350 [3.9] 13,750 [4.0] 13,950 [4.1] 13,600 [4.0] 14,250 [4.2] 12,400 [3.6] 13,700 [4.0] 13,400 [3.9] 13,100 [3.8] 13,350 [3.9] 15,000 [4.4] 15,500 [4.5] 15,250 [4.5] 15,250 [4.5] 15,500 [4.5] 15,500 [4.5] 15,600 [4.6] 14,200 [4.2] 14,650 [4.3] 15,450 [4.5] 12,900 [3.8] 15,750 [4.6] 13,750 [4.0] 15,500 [4.5] 15,300 [4.5] 15,250 [4.5] 15,300 [4.5] 15,300 [4.5] 15,050 [4.4] 15,550 [4.6] 15,500 [4.5] 14,250 [4.2] 14,250 [4.2] 12.50 12.00 12.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 13.00 13.00 13.00 12.50 13.00 13.00 12.50 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.50 12.00 12.50 12.50 12.00 12.00 11.50 12.00 12.00 12.00 12.00 12.00 12.50 12.00 12.00 12.00 12.00 SEER Sound Rating dB Indoor CFM [L/s] 15.10 14.50 14.50 16.00 15.50 15.50 15.50 15.50 15.50 15.50 16.00 16.00 15.50 15.50 15.10 15.50 16.00 16.00 16.00 15.50 15.10 16.00 16.00 15.10 15.00 15.00 14.00 14.50 14.50 14.50 14.00 15.00 14.00 15.10 15.10 14.50 14.50 14.00 14.50 14.50 14.50 14.50 14.50 15.10 14.50 14.50 14.50 14.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,375 [649] 1,500 [708] 1,575 [743] 1,450 [684] 1,400 [661] 1,400 [661] 1,450 [684] 1,575 [743] 1,575 [743] 1,600 [755] 1,600 [755] 1,600 [755] 1,450 [684] 1,450 [684] 1,700 [802] 1,600 [755] 1,550 [731] 1,525 [720] 1,550 [731] 1,450 [684] 1,700 [802] 1,450 [684] 1,500 [708] 1,600 [755] 1,600 [755] 1,600 [755] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,400 [661] 1,625 [767] 1,550 [731] 1,425 [672] 1,400 [661] 1,375 [649] 1,600 [755] 1,400 [661] 1,425 [672] 1,450 [684] 1,400 [661] 1,400 [661] 1,450 [684] 1,400 [661] 1,400 [661] 1,575 [743] 1,600 [755] Air Performance Data RAPM- JEZ Series Indoor CFM [L/s] Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers Outdoor Unit RAPMRev. 6/14/12 048JEZ Indoor Coil and/or Air Handler RCQD-4824(RGPE-10?BRM?) RCQD-4824(RGPE-12?ARM?) RCQD-4824(RGPT-07?BRQ?) RCQD-4824(RGPT-10?BRM?) RCQD-4824(RGPT-12?ARM?) RCQD-4824(RGRM-09?ZAJ?) RCQD-4824(RGRM-12?RAJ?) RCQD-4824(RHWB-08WRX60A) RCQD-4824(RHWB-10WRX60A) RCQD-4824(ROLA-070E04) RCQD-4824(ROLA-115E05) RCQD-4824+RXMD-C04 RHKL-HM4821(RCSL-H*4821) RHLL-HM4821(RCSL-H*4821) RHSL-HM4821(RCSL-H*4821) RHSL-HM4824(RCSL-H*4821) RHKL-HM4824(RCSL-H*4824) RHLL-HM4824(RCSL-H*4824) RHPN-HM4824(RCSN-H*4824) Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER SEER Sound Rating dB 48,000 [14.1] 48,500 [14.2] 48,500 [14.2] 48,000 [14.1] 48,000 [14.1] 48,000 [14.1] 48,000 [14.1] 48,000 [14.1] 48,500 [14.2] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 48,500 [14.2] 49,000 [14.4] 52,000 [15.2] 33,800 [9.9] 34,250 [10.0] 33,800 [9.9] 32,700 [9.6] 32,300 [9.5] 35,350 [10.4] 35,450 [10.4] 32,600 [9.6] 34,100 [10.0] 31,750 [9.3] 31,900 [9.3] 33,750 [9.9] 31,950 [9.4] 31,950 [9.4] 32,950 [9.7] 32,800 [9.6] 34,050 [10.0] 34,900 [10.2] 38,400 [11.3] 14,200 [4.2] 14,250 [4.2] 14,700 [4.3] 15,300 [4.5] 15,700 [4.6] 12,650 [3.7] 12,550 [3.7] 15,400 [4.5] 14,400 [4.2] 15,750 [4.6] 15,600 [4.6] 13,750 [4.0] 15,550 [4.6] 15,550 [4.6] 14,550 [4.3] 14,700 [4.3] 14,450 [4.2] 14,100 [4.1] 13,600 [4.0] 12.00 12.00 12.50 12.50 12.50 12.00 12.50 13.00 13.00 12.50 12.50 11.50 13.00 13.00 12.00 12.00 13.00 13.00 13.00 14.50 14.50 15.10 15.10 15.10 14.50 15.00 16.00 16.00 15.00 15.00 14.00 15.50 16.00 14.50 14.50 16.00 16.00 16.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,625 [767] 1,625 [767] 1,550 [731] 1,450 [684] 1,400 [661] 1,400 [661] 1,425 [672] 1,375 [649] 1,525 [720] 1,375 [649] 1,400 [661] 1,600 [755] 1,400 [661] 1,400 [661] 1,525 [720] 1,500 [708] 1,600 [755] 1,625 [767] 1,600 [755] 37,300 [10.9] 38,100 [11.2] 38,300 [11.2] 38,750 [11.4] 38,750 [11.4] 39,500 [11.6] 38,300 [11.2] 37,700 [11.0] 38,950 [11.4] 37,600 [11.0] 39,550 [11.6] 39,550 [11.6] 39,200 [11.5] 37,800 [11.1] 37,250 [10.9] 37,300 [10.9] 38,100 [11.2] 38,100 [11.2] 38,300 [11.2] 38,750 [11.4] 38,750 [11.4] 39,500 [11.6] 38,300 [11.2] 37,700 [11.0] 38,950 [11.4] 37,600 [11.0] 39,550 [11.6] 39,550 [11.6] 39,200 [11.5] 15,200 [4.5] 14,900 [4.4] 14,700 [4.3] 14,750 [4.3] 14,750 [4.3] 14,000 [4.1] 14,700 [4.3] 15,300 [4.5] 14,550 [4.3] 15,400 [4.5] 13,950 [4.1] 13,950 [4.1] 14,300 [4.2] 15,200 [4.5] 15,250 [4.5] 15,200 [4.5] 14,900 [4.4] 14,900 [4.4] 14,700 [4.3] 14,750 [4.3] 14,750 [4.3] 14,000 [4.1] 14,700 [4.3] 15,300 [4.5] 14,550 [4.3] 15,400 [4.5] 13,950 [4.1] 13,950 [4.1] 14,300 [4.2] 12.00 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.50 13.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.00 12.50 12.50 12.50 13.00 12.00 12.00 12.00 14.50 14.50 14.50 15.10 15.10 14.50 14.50 15.10 15.10 15.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 15.10 15.10 14.50 14.50 15.10 15.10 15.50 14.50 14.50 14.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,525 [720] 1,575 [743] 1,600 [755] 1,600 [755] 1,600 [755] 1,700 [802] 1,600 [755] 1,550 [731] 1,625 [767] 1,550 [731] 1,700 [802] 1,700 [802] 1,650 [779] 1,500 [708] 1,500 [708] 1,525 [720] 1,575 [743] 1,575 [743] 1,600 [755] 1,600 [755] 1,600 [755] 1,700 [802] 1,600 [755] 1,550 [731] 1,625 [767] 1,550 [731] 1,700 [802] 1,700 [802] 1,650 [779] 52,500 [15.4] RCFL-H*6024+RXMD-C04 ➀ RCFL-A*6024(RGGE-12?RCM?) 53,000 [15.5] RCFL-A*6024(RGLE-07?BRQ?) 53,000 [15.5] RCFL-A*6024(RGLE-10?BRM?) 53,500 [15.7] RCFL-A*6024(RGLE-12?ARM?) 53,500 [15.7] RCFL-A*6024(RGLT-12?ARM?) 53,500 [15.7] RCFL-A*6024(RGPE-07?BRQ?) 53,000 [15.5] RCFL-A*6024(RGPE-10?BRM?) 53,000 [15.5] RCFL-A*6024(RGPE-12?ARM?) 53,500 [15.7] RCFL-A*6024(RGPT-07?BRQ?) 53,000 [15.5] RCFL-A*6024(RGPT-10?BRM?) 53,500 [15.7] RCFL-A*6024(RGPT-12?ARM?) 53,500 [15.7] RCFL-A*6024(RHWB-08WRX60A) 53,500 [15.7] RCFL-A*6024(RHWB-10WRX60A) 53,000 [15.5] RCFL-A*6024(ROLA-115E05) 52,500 [15.4] 056JEZ RCFL-A*6024+RXMD-C04 52,500 [15.4] RCFL-H*6024(RGGE-12?RCM?) 53,000 [15.5] RCFL-H*6024(RGJF-12?RCM?) 53,000 [15.5] RCFL-H*6024(RGLE-07?BRQ?) 53,000 [15.5] RCFL-H*6024(RGLE-10?BRM?) 53,500 [15.7] RCFL-H*6024(RGLE-12?ARM?) 53,500 [15.7] RCFL-H*6024(RGLT-12?ARM?) 53,500 [15.7] RCFL-H*6024(RGPE-07?BRQ?) 53,000 [15.5] RCFL-H*6024(RGPE-10?BRM?) 53,000 [15.5] RCFL-H*6024(RGPE-12?ARM?) 53,500 [15.7] RCFL-H*6024(RGPT-07?BRQ?) 53,000 [15.5] RCFL-H*6024(RGPT-10?BRM?) 53,500 [15.7] RCFL-H*6024(RGPT-12?ARM?) 53,500 [15.7] RCFL-H*6024(RHWB-08WRX60A) 53,500 [15.7] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 29 Air Performance Data RAPM- JEZ Series Performance Data @ AHRI Standard Conditions—Cooling 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Model Numbers SEER Sound Rating dB Indoor CFM [L/s] 12.00 12.00 11.50 11.50 11.00 11.00 11.00 11.00 11.50 11.50 11.50 11.50 11.50 11.50 11.50 12.00 12.00 12.00 11.00 11.50 11.50 11.00 13.00 13.00 14.50 14.50 14.00 14.00 13.50 13.50 13.50 13.50 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.50 14.50 14.50 13.50 13.50 14.00 13.50 16.00 16.00 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,500 [708] 1,500 [708] 1,800 [849] 1,400 [661] 1,425 [672] 1,625 [767] 1,400 [661] 1,400 [661] 1,450 [684] 1,400 [661] 1,400 [661] 1,575 [743] 1,600 [755] 1,625 [767] 1,625 [767] 1,550 [731] 1,450 [684] 1,400 [661] 1,550 [731] 1,400 [661] 1,400 [661] 1,600 [755] 1,600 [755] 1,550 [731] 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 11.50 12.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 12.50 12.50 11.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 13.50 15.00 14.00 14.00 14.00 14.00 14.00 14.00 13.50 15.00 15.00 13.50 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 1,600 [755] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,675 [790] 1,600 [755] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,675 [790] 1,800 [849] 1,700 [802] 1,625 [767] 1,625 [767] 1,725 [814] 1,725 [814] 1,725 [814] 1,675 [790] 1,600 [755] 1,800 [849] 1,800 [849] 1,800 [849] Outdoor Unit RAPM- Indoor Coil and/or Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] EER Rev. 6/14/12 056JEZ RCFL-H*6024(RHWB-10WRX60A) RCFL-H*6024(ROLA-115E05) RBHP-25(RCHL-60A1) RCQD-6024(RGFE-09?ZCM?) RCQD-6024(RGFE-10?ZCM?) RCQD-6024(RGFE-12?RCM?) RCQD-6024(RGFG-09?ZCM?) RCQD-6024(RGFG-10?ZCM?) RCQD-6024(RGFG-12?RCM?) RCQD-6024(RGJF-09?ZCM?) RCQD-6024(RGJF-10?ZCM?) RCQD-6024(RGJF-12?RCM?) RCQD-6024(RGPE-07?BRQ?) RCQD-6024(RGPE-10?BRM?) RCQD-6024(RGPE-12?ARM?) RCQD-6024(RGPT-07?BRQ?) RCQD-6024(RGPT-10?BRM?) RCQD-6024(RGPT-12?ARM?) RCQD-6024(RGRM-12?RAJ?) RCQD-6024(ROCA-070E04) RCQD-6024(ROLA-115E05) RCQD-6024+RXMD-C04 RHKL-HM6024(RCSL-H*6024) RHLL-HM6024(RCSL-H*6024) 53,000 [15.5] 52,500 [15.4] 49,500 [14.5] 49,000 [14.4] 49,000 [14.4] 49,500 [14.5] 48,500 [14.2] 48,500 [14.2] 49,000 [14.4] 49,000 [14.4] 49,000 [14.4] 50,000 [14.6] 50,000 [14.6] 50,000 [14.6] 50,000 [14.6] 50,000 [14.6] 49,500 [14.5] 49,500 [14.5] 49,500 [14.5] 48,500 [14.2] 49,000 [14.4] 49,000 [14.4] 54,000 [15.8] 54,000 [15.8] 37,800 [11.1] 37,250 [10.9] 33,850 [9.9] 32,500 [9.5] 32,700 [9.6] 34,400 [10.1] 32,650 [9.6] 32,650 [9.6] 33,400 [9.8] 32,450 [9.5] 32,500 [9.5] 34,800 [10.2] 34,800 [10.2] 34,800 [10.2] 34,750 [10.2] 34,350 [10.1] 33,200 [9.7] 32,800 [9.6] 34,050 [10.0] 32,050 [9.4] 32,400 [9.5] 34,050 [10.0] 39,100 [11.5] 38,670 [11.3] 15,200 [4.5] 15,250 [4.5] 15,650 [4.6] 16,500 [4.8] 16,300 [4.8] 15,100 [4.4] 15,850 [4.6] 15,850 [4.6] 15,600 [4.6] 16,550 [4.8] 16,500 [4.8] 15,200 [4.5] 15,200 [4.5] 15,200 [4.5] 15,250 [4.5] 15,650 [4.6] 16,300 [4.8] 16,700 [4.9] 15,450 [4.5] 16,450 [4.8] 16,600 [4.9] 14,950 [4.4] 14,900 [4.4] 15,330 [4.5] 060JEZ RCFL-H*6024+RXMD-C04 ➀ RCFL-A*6024(RGLT-10?BRM?) RCFL-A*6024(RGLT-12?ARM?) RCFL-A*6024(RGPT-07?BRQ?) RCFL-A*6024(RGPT-10?BRM?) RCFL-A*6024(RGPT-12?ARM?) RCFL-A*6024(RGTM-10?RBJ?) RCFL-A*6024+RXMD-C04 RCFL-H*6024(RGLT-10?BRM?) RCFL-H*6024(RGLT-12?ARM?) RCFL-H*6024(RGPT-07?BRQ?) RCFL-H*6024(RGPT-10?BRM?) RCFL-H*6024(RGPT-12?ARM?) RCFL-H*6024(RGTM-10?RBJ?) RBHP-25(RCHL-60A1) RBHM-26J(RCQD-6024) RCQD-6024(RGPE-10?BRM?) RCQD-6024(RGPE-12?ARM?) RCQD-6024(RGPT-07?BRQ?) RCQD-6024(RGPT-10?BRM?) RCQD-6024(RGPT-12?ARM?) RCQD-6024(RGTM-10?RBJ?) RCQD-6024+RXMD-C04 RHKL-HM6024(RCSL-H*6024) RHLL-HM6024(RCSL-H*6024) RHSL-HM6024(RCSL-H*6024) 60,500 [17.7] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 60,500 [17.7] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 61,000 [17.9] 54,000 [15.8] 60,000 [17.6] 59,000 [17.3] 59,000 [17.3] 59,500 [17.4] 59,500 [17.4] 59,500 [17.4] 59,000 [17.3] 58,500 [17.1] 62,000 [18.2] 62,000 [18.2] 60,500 [17.7] 41,500 [12.2] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 42,800 [12.5] 41,500 [12.2] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 42,800 [12.5] 35,850 [10.5] 42,500 [12.5] 40,500 [11.9] 40,500 [11.9] 42,000 [12.3] 42,000 [12.3] 42,000 [12.3] 41,500 [12.2] 40,000 [11.7] 45,000 [13.2] 45,000 [13.2] 43,500 [12.7] 19,000 [5.6] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,200 [5.3] 19,000 [5.6] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,000 [5.3] 18,200 [5.3] 18,150 [5.3] 17,500 [5.1] 18,500 [5.4] 18,500 [5.4] 17,500 [5.1] 17,500 [5.1] 17,500 [5.1] 17,500 [5.1] 18,500 [5.4] 17,000 [5.0] 17,000 [5.0] 17,000 [5.0] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 30 Air Electrical and Physical Data RAPM- JEZ Series Electrical and Physical Data ELECTRICAL PHYSICAL Model Compressor Fuse or HACR Fan Motor Minimum Outdoor Coil Phase Number Circuit Breaker Full Load Circuit Rated Load Locked Rotor RAPM- Frequency (Hz) Amperes Amperes Amperes Ampacity Minimum Maximum Face Area No. Voltage (Volts) (FLA) Amperes Amperes Amperes Sq. Ft. [m2] Rows CFM [L/s] (RLA) (LRA) Refrig. Per Circuit Oz. [g] Weight Net Lbs. [kg] Shipping Lbs. [kg] Rev. 6/14/2012 018JEZ 1-60-208/230 9/9 48 1.9 14/14 20/20 20/20 11 [1.02] 1 1955 [923] 82 [2325] 145.5 024JEZ 1-60-208/230 13.5/13.5 58.3 1.1 18/18 25/25 30/30 20 [1.86] 1 3295 [1555] 128 [3629] 199.5 [90.5] 214.5 [90.5] [66] 160.5 [66] 030JEZ 1-60-208/230 12.8/12.8 64 1.9 18/18 25/25 30/30 20 [1.86] 1 3645 [1720] 129 [3657] 201 [91.2] 214 [91.2] 036JEZ 1-60-208/230 16/16 79 1.9 22/22 30/30 35/35 23.01 [2.14] 1 3680 [1737] 146 [4139] 205 [93] 227 [93] 042JEZ 1-60-208/230 17.9/17.9 112 2.8 26/26 30/30 40/40 23.01 [2.14] 1 3925 [1852] 152 [4309] 234 [106.1] 256 [106.1] 048JEZ 1-60-208/230 21.8/21.8 117 2.8 31/31 40/40 50/50 23.01 [2.14] 2 3685 [1739] 203 [5755] 273 [123.8] 298 [123.8] 056JEZ 1-60-208/230 21.4/21.4 135 2.8 30/30 35/35 50/50 23 [2.14] 2 3685 [1739] 255 [7229] 281.5 [127.7] 306.5 [127.7] 060JEZ 1-60-208/230 26.4/26.4 134 2.8 36/36 45/45 60/60 23 [2.14] 2 4350 [2053] 262 [7428] 281.5 [127.7] 306.5 [127.7] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. [ ] Designates Metric Conversions 31 Air Unit Dimensions RAPM- JEZ Series Unit Dimensions Model Number RAPM018JEZ Height “H” (Inches) [mm] 19 [483] Length “L” (Inches) [mm] 401/2 [1029] Width “W” (Inches) [mm] 275/8 [702] 024JEZ/030JEZ 29 [737] 443/8 [1127] 311/2 [800] 036JEZ/042JEZ/ 048JEZ/056JEZ/060JEZ 33 [838] 443/8 [1127] 311/2 [800] [ ] Designates Metric Conversions AIR DISCHARGE ALLOW 60⬙ [1524 mm] CLEARANCE LOW VOLTAGE 7/8⬙ [22 mm] W SERVICE FITTINGS L HIGH VOLTAGE 111/32⬙ [34 mm] ACCESS PANEL H A-0 AIR INLETS (LOUVERS) ALLOW 6⬙ [152 mm] MIN. CLEARANCE 3 SIDES 32 A-0 0001 ALLOW 24⬙ [610 mm] ACCESS CLEARANCE 0003 VAPOR LINE CONNECTION HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & 7 2 /8⬙ [73 mm] DIA. VALVES ALLOW ACCESSORY 24⬙ [610 mm] KNOCKOUTS CLEARANCE ONE SIDE Air Refrigerant Line Size Information RAPM- JEZ Series Condensing Unit Refrigerant Line Size Information Liquid Line Sizing (R-410A) Liquid Line Size – Outdoor Unit Above Indoor Coil Liquid Line Size – Outdoor Unit Below Indoor Coil (Cooling Only – Does not apply to Heat Pumps) Line Size Line Size Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m] System Connection (Inch O.D.) Capacity 25 50 75 100 125 150 25 50 75 100 125 150 (Inch I.D.) [mm] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m] 1/4* [6.35] 0 0 0 0 8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A 3/8″ 11/2 Ton 5/16 [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94] 2 Ton 3/8″ 21/2 Ton 3/8″ 3 Ton 3/8″ 31/2 Ton 3/8″ 4 Ton 3/8″ 5 Ton 3/8″ 3/8* [9.53] 1/4* [6.35] 0 0 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73] 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] N/A N/A N/A N/A N/A 5/16 [7.94] 3/8* [9.53] 1/4* [6.35] 5/16 [7.94] 0 0 0 0 3/8* [9.53] 5/16* [7.94] 3/8* [9.53] 0 0 0 0 0 0 0 0 0 5/16* [7.94] 0 0 0 3/8* [9.53] 3/8* [9.53] 1/2 [12.57] 3/8* [9.53] 1/2 [12.57] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 [4.27] 56 [17.07] 98 [29.87] 0 0 0 0 0 0 0 0 N/A 0 0 0 0 0 0 N/A 0 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81] 25 [7.62] N/A N/A N/A N/A N/A 25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 0 25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A 0 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 50 [15.24] 46 [14.02] 50 [15.24] 50 [15.24] 50 [15.24] 43 [13.11] 38 [11.58] 56 [17.07] 56 [17.07] 75 [22.86] N/A 36 [10.97] 30 [9.14] 55 [16.76] 44 [13.41] 81 [24.69] N/A N/A 30 [9.14] 24 [7.32] 22 [6.71] 15 [4.57] 53 [16.15] 52 [15.85] 32 [9.75] 20 [6.10] 79 [24.08] 76 [23.16] NOTES: *Standard line size N/A = Application not recommended. Suction Line Length/Size versus Capacity Multiplier (R-410A) Unit Size 11/2 Ton Suction Line Connection Size Suction Line Run— Feet [m] 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] Optional Standard Optional Optional Standard Optional Optional Standard Optional Optional Standard Optional 2 Ton 3/4" 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .94 N/A 3 Ton [19.05 mm] I.D. 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .93 N/A 21/2 Ton 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt. 1.00 1.00 1.00 .96 .98 .99 .94 .96 .97 .91 .93 .95 31/2 Ton 7/8" 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .94 .96 N/A 5 Ton [22.23 mm] I.D. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* 1.00 1.00 N/A .98 .99 N/A .96 .97 N/A .94 .95 N/A 4 Ton 7/8" [22.23 mm] O.D. Opt. 11/8" [28.58 mm] O.D. Std.* 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .95 .96 N/A 1.00 1.00 N/A .99 .99 N/A .97 .98 N/A .94 .97 N/A NOTES: *Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. [ ] Designates Metric Conversions 33 Air Limited Warranty RAPM- JEZ Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 34 Conditional Compressor (Registration Required) ...............................Ten (10) Years Parts ............................................................Ten (10) Years Air Notes RAPM- JEZ Series 35 The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A 06/12 QG FORM NO. A11-214
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 9.5.0 (Macintosh) Create Date : 2012:06:27 12:04:12-05:00 Modify Date : 2012:06:29 13:39:10-05:00 Title : untitled Has XFA : No Page Count : 36EXIF Metadata provided by EXIF.tools