Air

Gas Furnaces
R802V (UF/HZ) Series

Rheem Prestige™ Series Communicating
Two-Stage Variable Speed
Upflow/Horizontal Gas Furnace

R802V- Upflow/Horizontal Series
80% A.F.U.E.†
Input Rates 50-125 kBTU

✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.

• 80% residential Gas Furnace CSA certified
• Two stages of operation to save energy and maintain optimal
comfort level.
• Variable speed blower motor technology provides ultimate
humidity control quieter sound levels and year round energy
savings
• EcoNet enabled HVAC product
• 3 way multi poise design UF / HZ
• PlusOne™ Diagnostics — 7 Segment LED all units
• PlusOne™ Ignition System – DSI for reliability and longevity
• Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
• Solid doors provide quiet operation
• Solid bottom

• Insulated blower compartment
• Low profile 34" cabinet ideal for space constrained
installations
• Blower shelf design – serviceable in all furnace orientations
• Hemmed edges on cabinets and doors
• 1/4 turn door knobs for tool less access
• Integrated Control board features dip switches for easy
system set up
• QR code for quick access to product information from your
smart phone or tablet
• Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.

FORM NO. G11-546 REV. 1

Air

Table of Contents
R802V (UF/HZ) Series

TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data ........................................................................................6-7
Blower Performance Data ................................................................................8
Accessories....................................................................................................9
Limited Warranty ..........................................................................................10

2

Air

Standard & Optional Equipment
R802V (UF/HZ) Series

PATENTED HEAT EXCHANGER

DRAFT INDUCER MOTOR

IN-SHOT BURNERS

DIRECT SPARK IGNITOR

INTEGRATED FURNACE
CONTROL

ECM MOTOR

STANDARD EQUIPMENT

OPTIONAL EQUIPMENT

Completely assembled and wired; 2 speed induced draft blower; high
and low pressure switches; 2 stage redundant main gas control;
blower compartment door safety switch; solid state time on/time off
blower control; limit control; transformer; ECM blower motor. Furnaces
are equipped with cooling/heating relay and transformer (50VA) ready
for air conditioning applications. (Please note: a thermostat is not
included as standard equipment.) Flame sensor diagnostics; fusedprotection (secondary), 3rd speed option for continuous fan.

Side and bottom filter frame assembly. 4" Flue Adapter
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local
service dealer to use L.P. (propane) gas without changing burners.
Factory approved kits must be used to convert from natural to L.P.
(propane) gas and may be ordered as optional accessories from a
Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, direct spark ignition
is 100% safety lockout type.

WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
3

Air

Model Features/Physical Data & Specifications
R802V (UF/HZ) Series

Model Features
• 80% residential Gas Furnace CSA certified
• Two stages of operation to save energy and maintain optimal
comfort level.
• Variable speed blower motor technology provides ultimate
humidity control quieter sound levels and year round energy
savings
• EcoNet enabled HVAC product
• 3 way multi poise design UF / HZ
• PlusOne™ Diagnostics — 7 Segment LED all units
• PlusOne™ Ignition System – DSI for reliability and longevity
• Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
• Solid doors provide quiet operation

• Solid bottom
• Insulated blower compartment
• Low profile 34" cabinet ideal for space constrained
installations
• Blower shelf design serviceable in all furnace orientations
• Hemmed edges on cabinets and doors
• 1/4 turn door knobs for tool less access
• Integrated Controls board features dip switches for easy
system set up
• QR code for quick access to product information from your
smart phone or tablet
• Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.

Physical Data and Specifications
MODEL NUMBERS R802V SERIES

R802VA050317M*A

R802VA075317M*A

R802VA075421M*A

R802VA100521M*A

R802VA125524M*A

High Input-BTU/Hr [kW] ➁
Heating Capacity BTU/Hr [kW] ➀
Low Input BTU/Hr [kW] ➁
Heating Capacity BTU/Hr [kW] ➀
Heat Ext. Static Pressure [kPa]

50,000 [15]
40,000 [12]
35,000 [10]
28,000 [8]
.10 [.025]

75,000 [22]
60,000 [18]
52,500 [15]
42,000 [12]
.12 [.029]

75,000 [22]
60,000 [18]
52,500 [15]
42,000 [12]
.12 [.029]

100,000 [29]
80,000 [23]
70,000 [20]
56,000 [16]
.15 [.037]

125,000 [37]
100,000 [29]
87,500 [25]
70,000 [20]
.20 [.05]

Blower (D x W) [mm]

11 x 7
[279 x 178]

11 x 7
[279 x 178]

11 x 7
[279 x 178]

11 x 10
[279 x 254]

11 x 10
[279 x 254]

Motor H.P.
Type [W]
Motor Full Load Amps

1/2

ECM
[373]

1/2

ECM
[373]

3/4

ECM
[560]

3/4

ECM
[560]

3/4

ECM
[560]

7.7

7.7

9.6

9.6

9.6

Cooling CFM @ Rating Point
[L/s]

1250
[590]

1650
[780]

1800
[850]

1750
[825]

1900
[900]

Max. E.S.P. (In. W.C.) [kPa]

1.0 [.249]

1.0 [.249]

1.0 [.249]

1.0 [.249]

1.0 [.249]

Temperature Rise Range °F
[°C]–High Input

25-55
[13.9-30.6]

25-55
[13.9-30.6]

25-55
[13.9-30.6]

35-65
[19.4-36.1]

35-65
[19.4-36.1]

Temperature Rise Range °F
[°C]–Low Input

20-50
[12.8-29.4]

20-50
[12.8-29.4]

20-50
[12.8-29.4]

30-60
[18.3-35]

30-60
[18.3-35]

155
[68.3]

155
[68.3]

165
[73.8]

180
[82.2]

180
[82.2]

125
[57]

125
[57]

140
[64]

140
[64]

150
[68]

80.0%

80.0%

80.0%

Max. Outlet Air Temp. °F
[°C]
Approx. Shipping Weight (Lbs.)
[kg]
AFUE ➀

80.0%
80.0%
NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2" [12 mm] N.P.T.
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index Form for high altitude derate.
* S = Standard, X = Low Nox

[ ] Designates Metric Conversions

4

Air

Model Number Identification
R802V (UF/HZ) Series

Model Number Identification
R

80

2

V

A

075

4

17

M

S

A

Rheem

80 =
80% AFUE

2 = Two Stage

V = Variable
Speed
ECM

Design Series
A = 1st Design

Input
BTU/HR [kW]
050 = 50,000 [15]
075 = 75,000 [22]
100 = 100,000 [29]
125 = 125,000 [37]

3 = Up to
3 Ton
4 = 21/2 to
4 Ton
5 = 31/2 to
5 Ton

Cabinet
Width
17 = 17.5"
21 = 21".0
24 = 24.5"

M = Multi

X = Low NOx
S = Standard

RevisionMarketing
(A – First Time
Release)

[ ] Designates Metric Conversions

5

Air

Dimensional Data
R802V (UF/HZ) Series

Upflow Application

Dimensional Data: Upflow Model
MODEL
R802V-

A

B

C

D

E

F

LEFT
SIDE

050, 075317
075421, 100
125

171/2 [445]
211/2 [533]
241/2 [622]

1611/32 [415]
1927/32 [504]
2311/32 [593]

123/8 [314]
141/8 [359]
157/8 [403]

➀
➀
➀

151/2 [381]
181/2 [470]
221/2 [559]

21/2 [64]
21/2 [64]
21/2 [64]

0
0
0

REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
RIGHT
BACK
TOP
FRONT
VENT
(LBS.) [kg]
SIDE
3 [76] ➁
0
1 [25] 3 [76] 6 [152] ➂ 125 [57]
0
0
1 [25] 3 [76] 6 [152] ➂ 140 [64]
0
0
1 [25] 3 [76] 6 [152] ➂ 150 [68]

NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes.
[ ] Designates Metric Conversions

6

Air

Dimensional Data
R802V (UF/HZ) Series

Horizontal Application

WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.

Dimensional Data: Horizontal Model
MODEL
R802V-

A

B

C

D

E

F

LEFT
SIDE

050, 075317
075421, 100
125

171/2 [445]
211/2 [533]
241/2 [622]

1611/32 [415]
1927/32 [504]
2311/32 [593]

123/8 [314]
141/8 [359]
157/8 [403]

➀
➀
➀

151/2 [381]
181/2 [470]
221/2 [559]

21/2 [64]
21/2 [64]
21/2 [64]

0
0
0

REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
RIGHT
BACK
TOP
FRONT
VENT
(LBS.) [kg]
SIDE
3 [76] ➁
0
1 [25] 3 [76] 6 [152] ➂ 125 [57]
0
0
1 [25] 3 [76] 6 [152] ➂ 140 [64]
0
0
1 [25] 3 [76] 6 [152] ➂ 150 [68]

NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes.
[ ] Designates Metric Conversions

7

Air

Blower Performance Data
R802V (UF/HZ) Series

Blower Performance Data
MODEL NUMBER

R802VA050317MSA R802VA075317MSA R802VA075421MSA R802VA100521MSA R802VA125524MSA

SW15 = OFF SW16 = OFF

890

1425

1345

1400

1985

SW15 = ON

790

1200

1100

1250

1700

SW16 = OFF

HIGH
HEATING CFM SW15 = OFF SW16 = ON
TARGET GAS
HEATING
AIRFLOW

TARGET
COOLING/
HEAT-PUMP
AIRFLOW

735

1075

960

1150

1530

SW13 = OFF SW14 = OFF

835

1125

1045

1200

1500

SW13 = ON SW14 = OFF
LOW
HEATING CFM SW13 = OFF SW14 = ON

590

950

865

1050

1275

SW15 = ON

SW16 = ON

DO NOT USE

SW13 = ON

SW14 = ON

510

825

665

950

1150

SW4 = OFF

SW5 = OFF

1200

1200

1600

2000

2000

SW4 = ON

SW5 = OFF

1000

1000

1400

1600

1600

SW5 = ON

800

800

1200

1400

1400

SW4 = ON

SW5 = ON

600

600

1000

1200

1200

SW4 = OFF

SW5 = OFF

900

900

1200

1500

1500

SW4 = ON
LOW
COOLING CFM SW4 = OFF

SW5 = OFF

750

750

1050

1200

1200

SW5 = ON

600

600

900

1050

1050

SW5 = ON

450

450

750

900

900

HIGH
COOLING CFM SW4 = OFF

SW4 = ON

[ ] Designates Metric Conversions

8

DO NOT USE

Air

Accessories
R802V (UF/HZ) Series

FOR HIGH ALTITUDES:

SIDE RETURN FILTER RACK: RXGF-CD
BOTTOM RETURN FILTER RACK FOR
UPFLOW APPLICATION: RXGF-CB
FILTER RACK FILTER SIZES* INCHES [mm]
MODEL
R802V

RXGF-CB
(UPFLOW/
HORIZONTAL)

RXGF-CD
(UPFLOW)
SIDE RETURN

050 & 075317

153/4 x 25
[400 x 635]

153/4 x 25
[400 x 635]

075421 & 100

191/4 x 25
[489 x 635]

153/4 x 25
[400 x 635]

125

223/4 x 25
[578 x 635]

153/4 x 25
[400 x 635]

OPTION CODE FOR HIGH ALTITUDE: U.S.
None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS: U.S.
None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting for high altitudes.
High altitude option codes are not required for these models.
However, the burner orifice size needs to be recalculated and verified
at elevations above 2000 ft. See Installation Instructions for more
information.
[ ] Designates Metric Conversions

INDOOR COIL CASINGS
ECONET CONTROL

MODEL
NUMBER

RECOMMENDED COMMUNICATING FURNACE CONTROL

RXBC-D17AI
RXBC-D21AI
RXBC-D21BI
RXBC-D24AI

4" FLUE ADAPTER: RXGW-C01

WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE
FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO
INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO
BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY
HAZARDOUS CONDITIONS.
FURNACE
WIDTH
IN. [mm]
171/2 [445]
211/2 [533]
241/2 [622]

SOLID
BOTTOM
KIT NO.
RXGB-D17
RXGB-D21
RXGB-D24

BASE
PLATE NO.
AE-61874-02
AE-61874-03
AE-61874-04

BASE
PLATE SIZE
IN. [mm]
151/8 x 239/16 [384 x 598]
185/8 x 239/16 [473 x 598]
255/8 x 239/16 [651 x 598]

RETST600SYS
CONTRACTOR BENEFITS:
• Auto/Self Configuration
• Day-at-a-glance scheduling, with programmable fan
• Intuitive wiring connections
• Dual fuel ready
• Automatically optimizes airflow
• System status & mode information
• Complete diagnostic information on display
HOMEOWNER BENEFITS:
• Large, easy to read icons and characters
• Auto-mode control
• Smart recovery
• Continuous Fan Mode (5 speeds)
• Humidity Control
• Water heater, pool heater integration* (check model compatibility)
*ECONET CONTROL ACCESSORIES:
Wall Plate = RCPN-AMC08
Face Plate = RETSTFPL

IMPORTANT: Existing Comfort Control 2 System Condensing Units &
Heat Pumps are compatible with EcoNet when matched with a
R802V Gas Furnace and with an EcoNet Translator (RETRN620CC2)
installed on the Comfort Control 2 System control board.
*Available through PROSTOCK®.

9

Air

Limited Warranty
R802V (UF/HZ) Series

GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For complete details of the Limited and Conditional Warranties,
including applicable terms and conditions, contact your local contractor
or the Manufacturer for a copy of the product warranty certificate.

10

Parts* ..........................................................Ten (10) Years
Heat Exchanger ........................................Limited Lifetime

Air

Notes
R802V (UF/HZ) Series

11

The new degree of comfort.™

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com

Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5

PRINTED IN U.S.A. 3/15 QG FORM NO. G11-546 REV. 1



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Has XFA                         : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 10.0.0 (Macintosh)
Create Date                     : 2015:03:04 15:25:37-06:00
Modify Date                     : 2015:03:09 12:34:25-05:00
Title                           : untitled
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu