Residential Gas INTEGRATED HOME COMFORT Classic Plus Heavy Duty Professional Water Power Direct Vent Water Heaters Professional Classic Plus™ Heavy Duty Power Direct Vent gas water heaters are a perfect choice for tight construction and indoor air quality Performance Plus… • Recovery Capacity: 72.8 gallons per hour (delivers approximately 120 gallons of hot water in the first hour)** • Enhanced flow brass drain valve Self-Diagnostic System • Low lead compliant • Electronic gas control for improved monitoring and service • Durable silicon nitride igniter (HSI) • Temperature and pressure relief valve included • Side taps for space heating Low Emissions • EverKleen™ patented system fights sediment build-up • Eco-friendly burner, low NOx design • Standard replacement parts Features Warranty • Two pipe system: one pipe pulls in outside air for combustion and the other exhausts combustion gases • 8-Year limited tank and parts warranty* • 120 VAC powered blower • New whisper quiet blower Flammable Vapor Detection System • Protective control system that disables the heater in the presence of flammable vapor accumulation Flexible Venting Options • Long venting lengths up to 100 feet • PVC, ABS, or CPVC vent pipe options • Vertical or horizontal termination • Concentric vent kit available • With ProtectionPlus™ the 8-year limited tank warranty becomes 12-year *See Residential Warranty Certificate for complete information Efficiency | All models tested a ccording to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of current ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction | Design certified by CSA: For operation at 160 degrees; meets all safety and construction requirements of ANSI Z21.10.3; as an automatic storage or instantaneous water heater; as an automatic circulating tank water heater; and for operation on combustible floors and in alcove installations. All models are North Carolina Code c ompliant. Certified for 150 PSI maximum working pressure. Longer Life Professional Classic Plus Heavy Duty Power Direct Vent 75-Gallon Capacities 75,100 Btu/h Natural and LP Gas • Premium grade anode rod provides long-lasting tank protection LEED Point = 1 See specifications chart on back. IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 03/15 WP FORM NO. PRO+G RHPDVHD Residential Gas INTEGRATED HOME COMFORT Classic Plus Heavy Duty Professional Water Power Direct Vent Water Heaters Professional Classic Plus™ Heavy Duty Power Direct Vent Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) T GAS INPUT IN RECOVERY IN Y THOUS. BTU/H G.P.H. 100° RISE** P GAL. MODEL E CAP. NUMBER NAT. LP NAT. LP Tall 75 PRO+G75-76N RH PDV Tall 75 PRO+G75-76P RH PDV HT. TO TOP OF VENT A HT. TO TOP OF TANK AIR INLET HT. DIAM. B C D HT. TO GAS CONN. E WATER CONN. CNTR. F HT. TO SIDE T&P VALVE G WATER FRONT CONN. TO SHIP. size BACK WT. H I (LBS) – 72.8 – 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 – 75.1 – 72.8 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 75.1 **Recovery Capacity is based upon a 100° F water temperature rise and calculated per ANSI Z21.10.3 standards. First hour hot water delivery is based upon 77° water temperature rise. T&P FITTING 3/4" N.P.T. SIDE TAPS D BA C 1/2" G COMBUSTION AIR INLET COMBUSTION EXHAUST (VENT) I H HOT WATER CONNECTION H E COLD WATER CONNECTION F Vent and Combustion Air Inlet System Information From Sea Level Through 2,000 ft. Above Sea Level Model Vent & Combustion Air-Inlet Min. Allowed Equiv. Vent & Combustion Max. Allowed Equiv. Vent & Combustion Vent and Combustion System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s) PRO+G75-76N RH PDV 3 8 50 90° Elbows – PRO+G75-76N RH PDV 3 8 40 – Concentric* PRO+G75-76N RH PDV 4 8 100 90° Elbows – From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level Model Vent & Combustion Air-Inlet Min. Allowed Equiv. Vent & Combustion Max. Allowed Equiv. Vent & Combustion Vent and Combustion System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s) PRO+G75-76N RH PDV 3 8 25 90° Elbows – PRO+G75-76N RH PDV 3 8 20 – Concentric* PRO+G75-76N RH PDV 4 8 100 90° Elbows – From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level Model Vent & Combustion Air-Inlet Min. Allowed Equiv. Vent & Combustion Max. Allowed Equiv. Vent & Combustion Vent and Combustion System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s) PRO+G75-76N RH PDV 4 8 50 90° Elbows – One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe. * Use only Rheem 3 inch concentric termination. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT 2 PRINTED IN U.S.A. 03/15 WP FORM NO. PRO+G RHPDVHD
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2015:03:02 13:31:46-06:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2015:03:05 14:24:10-06:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:03:05 14:24:10-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:7a9dd482-662b-b146-8952-a28719a05b29 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:F04F4A2EDA236811822AD019CA7A7AD8 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:099AAE8716206811822A96ECF5959976 Derived From Document ID : xmp.did:02A95166D23268118083929DE914427B Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:03:02 13:31:46-06:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools