Residential Gas
INTEGRATED
HOME CO M F O RT Classic Plus
Professional
Water
Powered Damper Water Heaters

The energy efficient Professional Classic Plus™
Powered Damper gas water heaters meet or
exceed the latest ENERGY STAR® requirements
Efficiency

Guardian System™ & Sensor

• .67 - .69 EF

• Exclusive air/fuel shut-off device

• Energy Star® rated

• Maintenance free – no filter to clean

Performance

• Disables the heater in the presence of
flammable vapor accumulation

• FHR: 68 - 89 gallons
• Recovery: Up 50.5 GPH at a
90° F rise, depending on model

Self-Diagnostic System

Combustion Shut-off System

Flame Arrestor Plate

• Electronic gas control for
improved monitoring and
service

Low Emissions
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx r­equirements

Maintenance Free

Longer Life
• Premium grade anode rod provides
long-lasting tank protection

High Altitude Compliant
•E
 coNet™ enabled for
­integration with home
automation, energy
management and
demand response systems

Technology
• 24 VAC flue damper,
110 VAC outlet ­
required

• Certified to 10,100 ft. above sea level
(50-gallon 50K Btu/h model certified
to 5,999 feet above sea level)

Plus…
• Dual certified for both potable water
and space heating
• Enhanced flow brass drain valve
• Temperature and pressure relief valve
included

• Includes 19-foot cord, 3-prong plug

• Low lead compliant

•S
 tandard Cat. I, double-wall, B-vent,
3" (4" adaptor included)

Warranty

What is a Powered Damper?

38, 40 and 50-Gallon Capacities
Up to 50,000 Btu/h
Natural and LP Gas

• Standard replacement parts
• 8-Year limited tank and parts warranty*

The 24-volt powered flue damper is
­positioned atop the unit. It opens and closes
automatically in response to gas-burner
­activity. When the combustion stops, it signals
the damper to close, trapping the heat inside
the flue and delivering more heat to the water.

Professional Classic Plus
Powered Damper

LEED Point = 1

• With ProtectionPlus™ the 8-year limited
tank warranty becomes 12-year
*See Residential Warranty Certificate for ­
complete information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.

See specifications chart on back.

IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT
PRINTED IN U.S.A. 03/15 WP FORM NO. PRO+G RHPD Rev. 1

Residential Gas
INTEGRATED
HOME COM F O RT Classic Plus
Professional
Water
Powered Damper Water Heaters

Professional Classic Plus™ Powered Damper Specifications
	

	
	
	
	
	

DESCRIPTION	

FEATURES	

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)	

ENERGY INFO.

T									
HT. TO		
WATER	
HT. TO	
WATER				
GAS INPUT IN	
RECOVERY IN	
FIRST HOUR
ENERGY
Y
		
	 HT. TO	 TANK		
GAS 	
VENT	
CONN.	 SIDE T&P	 CONN.	
SHIP.	
THOUS. BTU/H	
G.P.H. 90° RISE	
DEL. G.P.H.
FACTOR
P	 GAL.	MODEL	
	 VENT	 HT.	 DIAM.	CONN.	 SIZE	 CNTR.	 VALVE	 size	WT.	
E	 CAP.	 NUMBER	
NAT.	
LP	
NAT.	
LP	
NAT.	
LP	
A	
B	
C	
D	
E	
F	
G	
H	
(LBS)	
NAT.	
LP

	 Tall	

38	 PRO+G38-40N RH69 PD	

	 Tall	

38	 PRO+G38-36P RH69 PD	

	 Tall	

50	 PRO+G50-40N RH67 PD	

	 Tall	

50	 PRO+G50-36P RH67 PD	

	 Tall	

50	 PRO+G50-50N RH67 PD	

	Short	 40	 PRO+G40S-40N RH67 PD	
	Short	 40	

PRO+G40s-36P RH67 PD	

	Short	 50	 PRO+G50S-40N RH67 PD	
	Short	 50	 PRO+G50S-36P RH67 PD	

40	

–	40.4	–	68	
–	

–	36	–	36.4	–	
40	

68	

–	40.4	–	84	
–	

–	36	–	36.4	–	

84	

62-3/4	 57-3/4	 19-3/4	

14	

3 or 4	

8	

52-1/4	

3/4	

140	

62-3/4	 57-3/4	 19-3/4	

14	

3 or 4	

8	

52-1/4	

3/4	

140	

63	

58	

21-3/4	

14	

3 or 4	

8	

52-1/2	

3/4	

160	

63	

58	

21-3/4	

14	

3 or 4	

8	

52-1/2	

3/4	

160	

50	

–	50.5	–	87	
–	 63-1/2	58	 21-3/4	 14	

40	

–	40.4	–	72	
–	

–	36	–	36.4	–	
40	

72	

–	40.4	–	89	
–	

–	36	–	36.4	–	

89	

–

0.69	

–	0.69
–

0.67	

–	0.67

8	 52-1/2	 3/4	

160	

0.67	

–

55-1/2	 50-1/2	 21-3/4	

14	

3 or 4	

8	

44	

3/4	

140	

0.67	

–

55-1/2	 50-1/2	 21-3/4	

14	

3 or 4	

8	

44	

3/4	

140	

55-1/2	 50-1/2	 23-3/4	

14	

3 or 4	

8	

44	

3/4	

160	

55-1/2	 50-1/2	 23-3/4	

14	

3 or 4	

8	

44	

3/4	

160	

4	

	

–	0.67
–

0.67	

–	0.67	

Energy Factor based on D.O.E. (Department of Energy) test ­procedures.

ANODE ROD

H

H

HOT
WATER
CONNECTION

F
E

COLD
WATER
CONNECTION
3/4" N.P.T.
RELIEF
VALVE
OPENING

C
A B
1/2"

G

D

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT

2
PRINTED IN U.S.A. 03/15 WP FORM NO. PRO+G RHPD Rev. 1



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2015:03:02 12:42:02-06:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2015:03:05 14:21:45-06:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:03:05 14:21:45-06:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:2bf443d1-7162-f149-9355-03f4f5a22fd7
Original Document ID            : xmp.did:0A80117407206811B34BA559CEB6FCA7
Document ID                     : xmp.id:976EF44CD3236811822AD019CA7A7AD8
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:966EF44CD3236811822AD019CA7A7AD8
Derived From Document ID        : xmp.did:7836C5AC09206811822A99B419490D7A
Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2015:03:02 12:42:02-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu