Rheem Professional Classic Series Direct Vent For Manufactured Housing Specification Sheet
2015-04-02
: Rheem Rheem-Professional-Classic-Series-Direct-Vent-For-Manufactured-Housing-Specification-Sheet-683502 rheem-professional-classic-series-direct-vent-for-manufactured-housing-specification-sheet-683502 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Residential Gas INTEGRATED HOME COMFORT Classic Direct Vent Professional Water Water Heaters for Manufactured Housing Professional Classic™ Direct Vent gas water heaters from Rheem are certified for Manufactured Housing (HUD) and modular construction Efficiency Roof Jacks • .62 - .63 EF Performance • FHR: 64 gallons for 40-gallon model and 49 gallons for 30-gallon model • Recovery: 30.3 GPH at a 90° F rise Flexibility 12" Non-Adjustable & Air Inlet 15-32" Adjustable & Air Inlet 30-60" Adjustable & Air Inlet 48-95" Adjustable & Air Inlet AP12032E AP12032B AP12032C AP12032D Air Inlets 6" Non-Adjustable 11-22" Adustable AP12019B AP12017B Extension Pipe Kit • Field convertible controls for natural gas or LP operation included • No external door is required • Provides maximum design freedom since it can be placed anywhere within the home Roof Jack Extension Pipe Kit AP12021 oof jack and air inlet must be ordered separately R with 30 and 40-gallon direct vent models and must be in accordance with instructions furnished with the heater. No other roof jack or air inlet assemblies are approved for installation with this heater. Clamps and secure strapping are packed in water heater carton. • Hot water outlet located at top • Cold water inlet at side for fast, economical hook-up Adjustable Roof Jack Vent Design allows adjustment to roof pitches of up to 5/12". Four roof jacks available to accommodate roof thickness of 12" up to 95". Longer Life • Premium grade anode rod provides long-lasting tank protection Plus… • Piezo ignition – easy light pilot • Enhanced flow brass drain valve • Factory installed temperature and pressure relief valve – side location • Low lead compliant Direct Combustion Air Inlet • EverKleen™ patented system fights sediment build-up Air is drawn directly into combustion chamber through air inlet fixed to base; 1/2" screen for rodent p rotection. Warranty • 6-Year limited tank and parts warranty* *See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Professional Classic Direct Vent for Manufactured Housing 30 and 40-Gallon Capacities Up to 30,000 Btu/h Natural and LP Gas See dimensions chart on back. IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 02/15 WP FORM NO. PROG RHMHDV N Residential Gas INTEGRATED HOME COMFORT Classic Direct Vent Professional Water Water Heaters for Manufactured Housing Professional Classic™ Direct Vent for Manufactured Housing Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) T Y GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. E CAP. NUMBER NAT./LP NAT./LP NAT./LP A B C HT. TO GAS VENT CONN. SIZE D E ENERGY INFO. ROOF HT. TO WATER JACK SIDE T&P CONN. SHIP. VENT SIZE VALVE size WT. F G H (LBS) ENERGY FACTOR NAT./LP Tall 30 PROG30-30N RH63 MH DV 30 30.3 49 56-5/8 56-5/8 17-3/4 14-1/8 3 5 51-1/8 20 110 0.63 Tall 40 PROG40-30N RH62 MH DV 30 30.3 64 57-3/8 57-3/8 19-3/4 14-1/8 3 5 51-1/8 20 125 0.62 Energy Factor based on D.O.E. (Department of Energy) test p rocedures. ADJUSTS TO PITCHES OF UP TO 5/12" F 24" MIN. A B E 0" MIN. WALL CLEARANCE C RELIEF VALVE COLD WATER CONN. G 1/2" 2" D H WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT 2 PRINTED IN U.S.A. 02/15 WP FORM NO. PROG RHMHDV N
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:02:12 11:17:34-06:00 Metadata Date : 2015:02:12 11:17:37-06:00 Modify Date : 2015:02:12 11:17:37-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:0c4c6c54-16b3-3349-bf44-1b78babae457 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:FBEEF0CFAC216811808380A5C0DE1F0D Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:FAEEF0CFAC216811808380A5C0DE1F0D Derived From Document ID : xmp.did:D750EA49AA216811923FE75EA4967D1F Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:02:12 11:17:34-06:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools