Residential Gas INTEGRATED HOME C O M F O RT Classic Plus Professional Water Power Direct Vent Water Heaters Professional Classic Plus™ Power Direct Vent gas water heaters are a perfect choice for tight construction or when indoor air quality is a concern Efficiency Longer Life • 0.62 - 0.67** EF • Rheem exclusive R-Tech (resistored) anode rod provides long-lasting tank protection Performance • FHR: Up to 139 gallons for natural and LP gas High Altitude Compliant • Models are certified for applications up to 10,200 feet above sea level • Recovery: 40 to 75.8 at a 90 degree rise Self-Diagnostic System Plus… • Electronic gas control for improved monitoring and service • Enhanced flow brass drain valve • Temperature and pressure relief valve included Low Emissions • Low lead compliant • Eco-friendly burner, low NOx design • Durable silicon nitride igniter (HSI) Features • Side taps for space heating applications on 50-65, 65 and 75-gallon models • Two pipe system: one pipe pulls in outside air for combustion and the other exhausts combustion gases Professional Classic Plus Power Direct Vent 40 to 75-Gallon Capacities Up to 75,100 Btu/h Natural and LP Gas • EverKleen™ patented system fights sediment build-up • 120 VAC powered blower • Standard replacement parts • New whisper quiet blower Warranty Flammable Vapor Detection System • 8-Year limited tank and parts warranty* • Protective control system that disables the heater in the presence of flammable vapor accumulation Flexible Venting Options LEED Point = 1 • With ProtectionPlus™ the 8-year limited tank warranty becomes 10-year ProtectionPlus – order part number SP20081 (6 pack only) T&P FITTING 3/4" N.P.T. *See Residential Warranty Certificate for complete information • Long venting lengths up to 100 feet • PVC or CPVC certified to ULC-S636 vent pipe options COMBUSTION AIR INLET • Vertical or horizontal termination COMBUSTION EXHAUST (VENT) • Concentric vent kit available D I BA C H HOT WATER CONNECTION H COLD WATER CONNECTION DESCRIPTION FEATURES E F ROUGHING IN DIMENSIONS (SHOWN IN INCHES) T GAS INPUT IN RECOVERY IN FIRST HOUR Y NATURAL GAS THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. P GAL. MODEL E CAP. NUMBER NAT. LP NAT. LP NAT. LP HT. TO TOP OF VENT A HT. TO TOP OF TANK AIR INLET HT. DIAM. B C D HT. TO GAS CONN. E WATER CONN. CNTR. F G 1/2" ENERGY INFO. HT. TO WATER FRONT ENERGY SIDE T&P CONN. TO SHIP. FACTOR VALVE SIZE BACK WT. G H I (LBS) NAT. LP AVG. ANNUAL OPER. COST NAT Tall 40 PRO+G40T-40N CN67 PDV** 40 38 40.4 38.4 73 73 68-1/2 69-1/4 60-1/4 19-3/4 14 8 53-3/4 3/4 29-1/2 180 0.67 0.67 $272 Tall 50 PRO+G50T-40N CN67 PDV** 40 40 40.4 40.4 93 93 67-5/8 67-7/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 205 0.67 0.67 $272 Tall 50 PRO+G50T-65N CN62 PDV 65 47 65.7 47.5 111 92 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.62 0.62 $294 Tall 65 PRO+G65T-65N CN62 PDV 65 56 65.7 56.6 120 113 71-1/4 72-1/4 61-3/4 14-5/8 11 54 3/4 34-1/4 285 0.62 0.62 $294 Tall 75 PRO+G75T-75N CN62 PDV 75.1 70 75.8 70.7 139 139 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 0.62 0.62 $495† 23 Specify LP gas when ordering. Add gas input and "P" to model number. Example: PRO+G40T-38P CN67 PDV **ENERGY STAR® qualified models. See venting chart on back. IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN Residential Gas INTEGRATED HOME C O M F O RT Classic Plus Professional Water Power Direct Vent Water Heaters Air-Inlet Venting Information for PRO+G40T-40N CN67 PDV and PRO+G50T-40N CN67PDV Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G40T-40N CN67 PDV 2 PRO+G40T-40N CN67 PDV 3 PRO+G40T-40N CN67 PDV 3 PRO+G50T-40N CN67PDV 2 PRO+G50T-40N CN67PDV 3 PRO+G50T-40N CN67PDV 3 From Sea Level Through 5,999 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 30 7 60 7 50 7 30 7 60 7 50 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows Concentric* 90° Elbows – – Concentric* 90° Elbows Concentric* 90° Elbows – – Concentric* Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G40T-40N CN67 PDV 2 PRO+G40T-40N CN67 PDV 2 PRO+G40T-40N CN67 PDV 3 PRO+G40T-40N CN67 PDV 3 PRO+G50T-40N CN67PDV 2 PRO+G50T-40N CN67PDV 3 PRO+G50T-40N CN67PDV 3 From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 15 7 30 7 60 7 50 7 15 7 60 7 50 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows – – Concentric* 90° Elbows – – Concentric* – Concentric* 90° Elbows – – Concentric* Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G40T-40N CN67 PDV 2 PRO+G40T-40N CN67 PDV 3 PRO+G40T-40N CN67 PDV 3 PRO+G50T-40N CN67PDV 3 PRO+G50T-40N CN67PDV 3 From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 15 7 60 7 50 7 60 7 50 Vent and Combustion Air-Inlet System Termination(s) – Concentric* 90° Elbows – – Concentric* 90° Elbows – – Concentric* Air-Inlet Venting Information for PRO+G50T-65N CN62 PDV, PRO+G65T-65N CN62 PDV and PRO+G75T-75N CN62 PDV Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 4 PRO+G65T-65N CN62 PDV 3 PRO+G65T-65N CN62 PDV 3 PRO+G65T-65N CN62 PDV 4 PRO+G75T-75N CN62 PDV 3 PRO+G75T-75N CN62 PDV 3 PRO+G75T-75N CN62 PDV 4 From Sea Level Through 2,000 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 50 7 40 7 100 8 50 8 40 8 100 8 50 8 40 8 100 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows – – Concentric* 90° Elbows – 90° Elbows – – Concentric* 90° Elbows – 90° Elbows – – Concentric* 90° Elbows – Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 4 PRO+G65T-65N CN62 PDV 3 PRO+G65T-65N CN62 PDV 3 PRO+G65T-65N CN62 PDV 4 PRO+G75T-75N CN62 PDV 3 PRO+G75T-75N CN62 PDV 3 PRO+G75T-75N CN62 PDV 4 From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 50 7 40 7 100 8 30 8 20 8 100 8 25 8 20 8 100 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows – – Concentric* 90° Elbows – 90° Elbows – – Concentric* 90° Elbows – 90° Elbows – – Concentric* 90° Elbows – Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 4 PRO+G65T-65N CN62 PDV 4 PRO+G75T-75N CN62 PDV 4 From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 50 7 40 7 100 8 40 8 50 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows – – Concentric* 90° Elbows – 90° Elbows – 90° Elbows – Vent & Combustion Air-Inlet Model System Diameter (Inches) PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 3 PRO+G50T-65N CN62 PDV 4 From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) 7 25 7 20 7 100 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows – – Concentric* 90° Elbows – • One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe. * Use only Rheem 3 inch concentric termination. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT 2 PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:01:22 08:51:03-06:00 Metadata Date : 2014:01:22 08:51:06-06:00 Modify Date : 2014:01:22 08:51:06-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:03beb311-334e-fb42-a72f-61a3c0f552c0 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:A0D7BB9818206811822A816856947B3D Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9FD7BB9818206811822A816856947B3D Derived From Document ID : xmp.did:8AE8F0EC45356811822AAFC53C065F3E Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:01:22 08:51:03-06:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools