Rheem Professional Classic Series Power Direct Vent Specification Sheet
Rheem-Professional-Classic-Plus-Series-Heavy-Duty-Power-Direct-Vent-Specification-Sheet-683452 rheem-professional-classic-plus-series-heavy-duty-power-direct-vent-specification-sheet-683452
2015-04-02
: Rheem Rheem-Professional-Classic-Series-Power-Direct-Vent-Specification-Sheet-683478 rheem-professional-classic-series-power-direct-vent-specification-sheet-683478 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Professional Classic Plus™ Power Direct Vent gas
water heaters are a perfect choice for tight
construction or when indoor air quality is a concern
Efficiency
• 0 .62 - 0.67** EF
Performance
• FHR: Up to 139 gallons for natural
and LP gas
• Recovery: 40 to 75.8 at a
90 degree rise
Self-Diagnostic System
• Electronic gas control for
improved monitoring and
service
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Two pipe system: one pipe pulls in
outside air for combustion and the
other exhausts combustion gases
• 120 VAC powered blower
• New whisper quiet blower
Flammable Vapor
Detection System
• Protective control system that
disables the heater in the presence of
ammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 100 feet
• PVC or CPVC certied to ULC-S636
vent pipe options
• Vertical or horizontal termination
• Concentric vent kit available
Longer Life
• Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection
High Altitude Compliant
•
Models are certied for applications up
to 10,200 feet above sea level
Plus…
• Enhanced ow brass drain valve
• Temperature and pressure relief valve
included
• Low lead compliant
• Durable silicon nitride igniter (HSI)
• Side taps for space heating
applications on 50-65, 65 and
75-gallon models
• EverKleen™ patented system ghts
sediment build-up
• Standard replacement parts
Warranty
• 8-Year limited tank and parts
warranty*
• With ProtectionPlus
™
the 8-year limited
tank warranty becomes 10-year
ProtectionPlus – order part number
SP20081 (6 pack only)
* See Residential Warranty Certicate for
complete information
Professional Classic Plus
Power Direct Vent
40 to 75-Gallon Capacities
Up to 75,100 Btu/h
Natural and LP Gas
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
See venting chart on back.
LEED Point = 1
D
CG
B A
E
T&P FITTING
3/4" N.P.T.
1/2"
HOT
WATER
CONNECTION
COMBUSTION
EXHAUST
(VENT)
COMBUSTION
AIR INLET
H
COLD
WATER
CONNECTION
H
F
I
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT AVG.
Y NATURAL GAS GAS INPUT IN RECOVERY IN FIRST HOUR TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP. ENERGY ANNUAL
P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIZE BACK WT. FACTOR OPER. COST
E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP NAT
Tall 40 PRO+G40T-40N CN67 PDV** 40 38 40.4 38.4 73 73 68-1/2 69-1/4 60-1/4 19-3/4 14 8 53-3/4 3/4 29-1/2 180 0.67 0.67 $272
Tall 50 PRO+G50T-40N CN67 PDV** 40 40 40.4 40.4 93 93 67-5/8 67-7/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 205 0.67 0.67 $272
Tall 50 PRO+G50T-65N CN62 PDV 65 47 65.7 47.5 111 92 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.62 0.62 $294
Tall 65 PRO+G65T-65N CN62 PDV 65 56 65.7 56.6 120 113 71-1/4 72-1/4 61-3/4 23 14-5/8 11 54 3/4 34-1/4 285 0.62 0.62 $294
Tall 75 PRO+G75T-75N CN62 PDV 75.1 70 75.8 70.7 139 139 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 0.62 0.62 $495†
Specify LP gas when ordering. Add gas input and "P" to model number. Example: PRO+G40T-38P CN67 PDV
**ENERGY STAR
®
qualified models.
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
2
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
Air-Inlet Venting Information for PRO+G40T-40N CN67 PDV and PRO+G50T-40N CN67PDV
From Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 30 90° Elbows Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 2 7 30 90° Elbows Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 90° Elbows –
PRO+G40T-40N CN67 PDV 2 7 30 – Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 2 7 15 – Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 – Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
Air-Inlet Venting Information for PRO+G50T-65N CN62 PDV, PRO+G65T-65N CN62 PDV and PRO+G75T-75N CN62 PDV
From Sea Level Through 2,000 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 50 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 40 – Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 50 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 40 – Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows –
From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 30 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 20 – Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 25 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 20 – Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows –
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 4 8 40 90° Elbows –
PRO+G75T-75N CN62 PDV 4 8 50 90° Elbows –
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 25 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 20 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
• One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe.
* Use only Rheem 3 inch concentric termination.