Rheem Professional Classic Series Power Direct Vent Specification Sheet

Rheem-Professional-Classic-Plus-Series-Heavy-Duty-Power-Direct-Vent-Specification-Sheet-683452 rheem-professional-classic-plus-series-heavy-duty-power-direct-vent-specification-sheet-683452

2015-04-02

: Rheem Rheem-Professional-Classic-Series-Power-Direct-Vent-Specification-Sheet-683478 rheem-professional-classic-series-power-direct-vent-specification-sheet-683478 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Professional Classic PlusPower Direct Vent gas
water heaters are a perfect choice for tight
construction or when indoor air quality is a concern
Efficiency
• 0 .62 - 0.67** EF
Performance
FHR: Up to 139 gallons for natural
and LP gas
Recovery: 40 to 75.8 at a
90 degree rise
Self-Diagnostic System
Electronic gas control for
improved monitoring and
service
Low Emissions
Eco-friendly burner, low NOx design
Features
Two pipe system: one pipe pulls in
outside air for combustion and the
other exhausts combustion gases
120 VAC powered blower
New whisper quiet blower
Flammable Vapor
Detection System
Protective control system that
disables the heater in the presence of
ammable vapor accumulation
Flexible Venting Options
Long venting lengths up to 100 feet
PVC or CPVC certied to ULC-S636
vent pipe options
• Vertical or horizontal termination
• Concentric vent kit available
Longer Life
Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection
High Altitude Compliant
Models are certied for applications up
to 10,200 feet above sea level
Plus…
Enhanced ow brass drain valve
Temperature and pressure relief valve
included
• Low lead compliant
Durable silicon nitride igniter (HSI)
Side taps for space heating
applications on 50-65, 65 and
75-gallon models
EverKleen patented system ghts
sediment build-up
Standard replacement parts
Warranty
8-Year limited tank and parts
warranty*
With ProtectionPlus
the 8-year limited
tank warranty becomes 10-year
ProtectionPlus – order part number
SP20081 (6 pack only)
* See Residential Warranty Certicate for
complete information
Professional Classic Plus
Power Direct Vent
40 to 75-Gallon Capacities
Up to 75,100 Btu/h
Natural and LP Gas
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
See venting chart on back.
LEED Point = 1
D
CG
B A
E
T&P FITTING
3/4" N.P.T.
1/2"
HOT
WATER
CONNECTION
COMBUSTION
EXHAUST
(VENT)
COMBUSTION
AIR INLET
H
COLD
WATER
CONNECTION
H
F
I
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT AVG.
Y NATURAL GAS GAS INPUT IN RECOVERY IN FIRST HOUR TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP. ENERGY ANNUAL
P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIZE BACK WT. FACTOR OPER. COST
E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP NAT
Tall 40 PRO+G40T-40N CN67 PDV** 40 38 40.4 38.4 73 73 68-1/2 69-1/4 60-1/4 19-3/4 14 8 53-3/4 3/4 29-1/2 180 0.67 0.67 $272
Tall 50 PRO+G50T-40N CN67 PDV** 40 40 40.4 40.4 93 93 67-5/8 67-7/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 205 0.67 0.67 $272
Tall 50 PRO+G50T-65N CN62 PDV 65 47 65.7 47.5 111 92 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.62 0.62 $294
Tall 65 PRO+G65T-65N CN62 PDV 65 56 65.7 56.6 120 113 71-1/4 72-1/4 61-3/4 23 14-5/8 11 54 3/4 34-1/4 285 0.62 0.62 $294
Tall 75 PRO+G75T-75N CN62 PDV 75.1 70 75.8 70.7 139 139 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 0.62 0.62 $495†
Specify LP gas when ordering. Add gas input and "P" to model number. Example: PRO+G40T-38P CN67 PDV
**ENERGY STAR
®
qualified models.
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
2
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 www.rheem.com
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
Air-Inlet Venting Information for PRO+G40T-40N CN67 PDV and PRO+G50T-40N CN67PDV
From Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 30 90° Elbows Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows
PRO+G40T-40N CN67 PDV 3 7 50 Concentric*
PRO+G50T-40N CN67PDV 2 7 30 90° Elbows Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows
PRO+G50T-40N CN67PDV 3 7 50 Concentric*
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 90° Elbows
PRO+G40T-40N CN67 PDV 2 7 30 Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows
PRO+G40T-40N CN67 PDV 3 7 50 Concentric*
PRO+G50T-40N CN67PDV 2 7 15 Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows
PRO+G50T-40N CN67PDV 3 7 50 Concentric*
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows
PRO+G40T-40N CN67 PDV 3 7 50 Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows
PRO+G50T-40N CN67PDV 3 7 50 Concentric*
Air-Inlet Venting Information for PRO+G50T-65N CN62 PDV, PRO+G65T-65N CN62 PDV and PRO+G75T-75N CN62 PDV
From Sea Level Through 2,000 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows
PRO+G50T-65N CN62 PDV 3 7 40 Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows
PRO+G65T-65N CN62 PDV 3 8 50 90° Elbows
PRO+G65T-65N CN62 PDV 3 8 40 Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows
PRO+G75T-75N CN62 PDV 3 8 50 90° Elbows
PRO+G75T-75N CN62 PDV 3 8 40 Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows
From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows
PRO+G50T-65N CN62 PDV 3 7 40 Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows
PRO+G65T-65N CN62 PDV 3 8 30 90° Elbows
PRO+G65T-65N CN62 PDV 3 8 20 Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows
PRO+G75T-75N CN62 PDV 3 8 25 90° Elbows
PRO+G75T-75N CN62 PDV 3 8 20 Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows
PRO+G50T-65N CN62 PDV 3 7 40 Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows
PRO+G65T-65N CN62 PDV 4 8 40 90° Elbows
PRO+G75T-75N CN62 PDV 4 8 50 90° Elbows
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 25 90° Elbows
PRO+G50T-65N CN62 PDV 3 7 20 Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows
• One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe.
* Use only Rheem 3 inch concentric termination.