Rheem Professional Classic Series Power Vent Specification Sheet
2015-04-02
: Rheem Rheem-Professional-Classic-Series-Power-Vent-Specification-Sheet-683474 rheem-professional-classic-series-power-vent-specification-sheet-683474 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHPVCAN
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Professional Classic™ Power Vent gas water heaters
offer up to 100 foot vent runs, energy efficiency
and the Guardian System
Efficiency
®
Performance
Self-Diagnostic System
Low Emissions
Features
Guardian System™ & Sensor
Flexible Venting Options
Longer Life
High Altitude Compliant
Plus…
™
Warranty
™
Professional Classic
Power Vent
Maintenance Free
Flame Arrestor PlateCombustion Shut-off System
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic
Power Vent Water Heaters
See dimensions chart on back.
PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHPVCAN
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
Professional Classic™ Power Vent Specifications
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic
Power Vent Water Heaters
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO WATER HT. TO WATER AVG.
Y GAS INPUT IN RECOVERY IN FIRST HOUR TOP OF TANK GAS CONN. SIDE T&P CONN. SHIP. ENERGY ANNUAL
P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIzE WT. FACTOR OPER COST
E CAP. NUMBER NAT. LP NAT. LP NAT. A B C D E F G (LBS) NAT. NAT.
Short 40 PROG40S-36N CN67 PV 36 32 36.4 32.4 71 62-1/2 51-1/ 4 21-3/4 14 8 44-1/4 3/4 155 0.67 $272
Short 50 PROG50S-36N CN67 PV 36 32 36.4 32.4 85 62-1/ 2 51-1/4 23-3/4 14 8 44 3/4 175 0.67 $272
HOT
WATER
CONNECTION COLD
WATER
CONNECTION
POWER VENT
ASSEMBLY
C
BF
A
D
G
G
E
T&P FITTING
3/4" N.P. T.
1/2"
ANODE ROD
NUMBER OF MINIMUM MAXIMUM MAXIMUM
90° ELBOWS NUMBER PIPE PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH (FT.) LENGTH (FT.)
TERMINAL ELBOWS REq. (FT.) 0’ - 2000’ 2000’ - 7700’ *
One (1) None 4.0 44.0 24.0
One (1) One (1) 4.0 41.0 21.0
Two (2) None 4.0 38.0 18.0
Two (2) One (1) 4.0 35.0 15.0
Three (3) None 4.0 32.0 12.0
NUMBER OF MINIMUM MAXIMUM MAXIMUM
90° ELBOWS NUMBER PIPE PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH (FT.) LENGTH (FT.)
TERMINAL ELBOWS REq. (FT.) 0’ - 2000’ 2000’ - 7700’ *
One (1) None 5.0 95.0 75.0
One (1) One (1) 5.0 92.5 72.5
Two (2) None 5.0 90.0 70.0
Two (2) One (1) 5.0 87.5 67.5
Three (3) None 5.0 85.0 65.0
Maximum and Minimum Vent Lengths for 2” Vents Maximum and Minimum Vent Lengths for 3” Vents