Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
Users Manual 2
Introduction RISCO Group's 2-Way Wireless I/O & X10 Module is an extension module enabling wired devices to be connected to the Agility Wireless system. The Wireless I/O Module supports 4 hardwired zones, 4 outputs and controls up to 16 X10 devices. Each output or X10 device can be operated in a response to a wide variety of system events. For detailed information regarding the programming options of the Wireless I/O Module refer to the installation manuals of the Agility. Main Features Bi-directional wireless communication 2 Relay Outputs (3Amp) 2 Transistor Outputs (500 mA) 4 Inputs (NO, NC, EOL) Fully supervised Dual tamper protection (Box & Wall) X10 adapter, up to 16 X10 devices Wireless I/O Module - Main Components 1. RF Module 2. Input Terminals 3. Relay Output Terminals 4. Transistor Output terminals 5. AC Power terminals IN1 GND IN2 IN3 GND IN4 NO1 C1 NC1 NO2 C2 NC2 VO3 GND VO4 V11 V12 RF Module (parallel connection to J2) 6. Back/Wall tamper (not visible) 7. J2 Power socket 8. 3 LED indication 9. RJ11 connector (X10 connection) 10. Box tamper switch 11 11. Battery holders= 10 Figure 1: Wireless I/O Module Main Components Page 1 LED Indications LED (Red)= (Yellow) State Power Description On AC and batteries OK Flashing AC trouble or Low battery (below 3.1 VDC) Off Power not present On X10 Connected to the Wireless I/O Module Off X10 Disconnected On The I/O expander is communicating with the Agility Off No communication is taking place X10 Communication (Green) Mounting the Wireless I/O Module Select a mounting location near an AC power supply in proximity to the Agility main panel 1. Open the cover by twisting a screwdriver in the slots on the bottom or top of the case (Figure 2). Figure 2: Opening the Cover 2. Figure 3) and open knockouts for the entry of the power wires Remove the circuit board ( (1, Figure 4) and for the back tamper (2, Figure 4). Page 2 3. Mount the receiver on the wall using the installation holes (3, Figure 4) and reinstall the circuit board. Make sure that that you hear a "click" when attaching the tamper spring to the wall. UO1 Z3 3 COM Z3 4 Z35 COM Z36 N O C NC NO UO2 C NC UO3 C OM UO4 AC Figure 3: Circuit Board Removal 4. Figure 4: Knockouts and Installation Holes Connect the power source wire plug to the J2 power jack on the PCB or to the AC terminals on the PCB. The polarity is not important. Do Not plug the transformer into the wall outlet at this point. 5. Optional back-up batteries: Plug in three rechargeable batteries (size AA NiMH 2300 mAH) into the battery holders. Pay attention to the correct polarity (+) (-). NOTE: Rechargeable batteries should be charged for at least 24 hours. IMPORTANT When replacing the batteries be sure to use the same type. Failure to comply with this instruction may result in damage to personnel and/or equipment. Dispose of used batteries according to local regulations. 6. Set all inputs and output wiring, as described below. Page 3 Wiring the Wireless I/O module Inputs wiring The Agility supports 4 hardwire zones (defined in the Agility system as zones 33-36) that can be defined as Normally Open, Normally Closed or End of Line Zones. The following diagram illustrates the various zone connections: NORMALLY CLOSED ZONE CONFIGURATION NORMALLY OPEN ZONE CONFIGURATION COM COM END OF LINE ZONE (N.C CONTACT) END OF LINE ZONE (N.O CONTACT) COM COM 2.2 K ALARM ALARM DEVICE DEVICE DEVICE ALARM DEVICE ALARM Utility Outputs wiring The Agility includes 4 utility outputs (2 x 24VDC 3Amp relays and 2 x 13.8 VDC 500 mA transistor outputs). These outputs can operate external devices in response to a number of system activities. For detailed information regarding the programming of the utility outputs refer to the Agility Installer Guide. To wire Relay Outputs (UO1, UO2) Wire the devices that you want to activate to the outputs, as follows: NOTE: UO1 and UO2 connections are identical. NC: Normally closed contact C: Common contact NO: Normally open contact NORMALLY OPEN OUTPUT CONFIGURATION N.O UO N.C NORMALLY CLOSED OUTPUT CONFIGURATION N.O UO2 / UO1 EXTERNAL POWER UO EXTERNAL POWER UO1/UO2 behave as dry contacts Page 4 N.C To wire Transistor Outputs (UO3-UO4) Connect the positive connection of the device to to the GND (-) UO3 or UO4 (+) and the negative connection terminals. UO3 COM X10 Connection UO4 EXTERNAL POWER The wireless I/O expander enables the Agility to control X10 devices. The I/O expander converts the information sent from the programmable utility output into the X10 protocol. Up to sixteen X10 devices can be activated. These are recognized in the system as outputs 5 to 20. To connect the X10 Connect the X10 controller cable to the RJ11 connector located on the Wireless I/O module PCB. Transmitter/Receiver Communication Setup To set up the communication with the receiver, the I/O expander should identify itself to the system's receiver in the same way as setting communication to a wireless zone. IMPORTANT: Before proceeding with the steps below, plug the AC transformer into the wall outlet. 1. Set the security panel to Learn mode. 2. Send a WRITE message by pressing the Wall and Cover tampers switches simultaneously for at least 3 seconds (when the PCB IS installed ONLY the cover tamper has to be pressed). 3. Verify that the I/O expander has been identified by the security panel. 4. Install the Wireless I/O Module front cover back in its place. Lock screw located at the top of the unit. Programming Changing Default Settings Via the Agility panel you can define the Inputs, Outputs and X10 parameters settings according to your requirements. For more information refer to the Agility Installer Manual. Page 5 Diagnostics You can perform diagnostic tests and check the status of the Inputs, Outputs connected to the Wireless I/O Module and the communication between the module and the Agility. The diagnostics can be performed locally from a keypad or remotely from the Configuration Software. Technical Specifications Electrical Characteristics Power Supply 9VAC, 0.5A minimum Current Consumption (Minimum / Maximum) 20 mA minimum / 150 mA maximum Backup Batteries 3 x size AA NiMH cylindrical cell 1.2V 2300 mAH Relay Outputs 2 x 3 Amps 24 VDC programmable Transistor Outputs 2 x 500mA transistors (Open Collector) Operating Temperature -10°C to 40°C (32°F to 131°F) Storage Temperature -20°C to 60°C (-4°F to 140°F) Physical Characteristics Dimension 14.5 cm x 9.0 cm x 4.0 cm (5.7 x 3.54 x 1.57 inch) Weight (with batteries) 0.24 Kg (0.52lb) Wireless Characteristics RF immunity According to EN 50130-4 Frequency 868.65 MHz or 433.92 MHz Compliance EN50131-1, EN50131-3 Grade 2 EN50130-5 Environmental class II EN50131-6 Type A Ordering Part Numbers Part number Description RW132I04000A 2-Way Wireless I/O & X10 Module, 868.65 MHz RW132I04000H 2-Way Wireless I/O & X10 Module, 433.92 MHz Page 6 FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. JE4AGILITY Valid for P/N RW132I04000H 6564A-AGILITY Valid for P/N RW132I04000H FCC ID: IC: FCC Warning The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. RISCO Group Limited Warranty RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers' obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or not be compromised or circumvented; that the product will prevent any persona; injury or property loss by intruder, robbery, fire or otherwise; or that the product will in all cas es provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week. Contacting RISCO Group RISCO Group is committed to customer service and product support. You can contact us through our website www.riscogroup.com or as follows: United Kingdom USA Tel:+44-161-655-5500 Tel:+305-592-3820 sales@riscogroup.co.uk sales@riscogroupusa.com technical@riscogroup.co.uk support@riscogroupusa.com Italy Brazil Tel: +39-02-66590054 Tel:+55-11-3661-8767 info@riscogroup.it sales-br@riscogroup.com support@riscogroup.it support-br@riscogroup.com Tel:+34-91-490-2133 Tel: +86-21-52390066 sales-es@riscogroup.com sales-cn@riscogroup.com support-es@riscogroup.com support-cn@riscogroup.com Tel: +33-164-73-28-50 Tel: +48-22-500-28-40 sales-fr@riscogroup.com Fax: +48-22-500-28-41 support-fr@riscogroup.com support-pl@riscogroup.com Tel: +32-2522 7622 Tel: +972-(0)3-963-7777 sales-be@riscogroup.com info@riscogroup.com support-be@riscogroup.com support@riscogroup.com Spain France Belgium China Poland Israel All rights reserved. No part of this document may be reproduced in any form without prior written permission from the publisher. © RISCO Group 05/08 5IN1038
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 8 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:95f6b51f-8537-4725-b3a4-a8a9d2340da6 Producer : Acrobat Distiller 6.0.1 (Windows) Modify Date : 2008:11:11 12:18:41+02:00 Create Date : 2008:11:11 12:18:41+02:00 Document ID : uuid:be3325a4-5b70-4fbc-99ed-28fbdd4468aa Format : application/pdf Title : untitled Creator : Author :EXIF Metadata provided by EXIF.tools