Risco CSMDTN Dual technology motion detector COSMOS DT User Manual correct

Risco Ltd. Dual technology motion detector COSMOS DT correct

Contents

correct user manual

GENERAL DESCRIPTIONThe COSMOS family includes the following models:•COSMOS PR: A microprocessor based Passive Infrared detector•COSMOS AM: Passive Infrared detector with anti-masking features.•COSMOS PET PR: A microprocessor based Passive Infrared detector withpet immunity•COSMOS PQ: A Quad PIR with two separate dual element pyroelectric sensors.•COSMOS DT: A Dual Technology detector offering both MW and IR technologies.•COSMOS DTAM: A Dual Technology detector with anti-masking features.•COSMOS PET DT: A Dual Technology detector with  pet immunity.The IR responds to changes in the ambient thermal radiation caused whenan intruder crosses the protected area.The MW transmits signals and analyzes the frequency changes of thereflected echo from an intruder due to Doppler effect.An ALARM is initiated only when both technologies trigger simultaneously.Detection occurs only in areas where IR and MW patterns overlap, greatlyreducing the chance of false alarms.The cosmos DT is available in the following versions:Table 1: Available COSMOS DT Lenses and Accessories.LED's  jumperLEDSMWModulePULSEJumperIR SensorMW RangeAdjustmentTamperSwitchACCESSORYTypical Mounting Height 2.5m 2.5m 2mWide Angle Lens RL-115 RL-125Long Range Lens *** *** RL-17Corridor Lens RL-15 ***Pet Alley set RA-12 ***Ceiling Mounted Swivel RA-90 ***Wall/Corner Mounted Swivel RA-91 ***DTI (UK) (10.687 GHz)RK - 210DTIRK - 215DTIRK - 225DTIRANGE10m/ 33ft15m/ 50ft25m/ 80ftFCC (USA)(10.525 GHz)UL ListedRK - 210FCRK - 215FCRK - 225FC1RK-225 RK-215 RK-210CAUTION:THE UNIT SHOULD NOT BE MOUNTED IN DIRECT SUNLIGHT OR NEARANY HEAT SOURCES. THE DETECTION SECTORS SHOULD BE POINTEDTOWARDS EITHER A WALL OR THE FLOOR (NOT WINDOWS ANDCURTAINS). INSTALL ON SMOOTH SURFACES ONLY.PRELIMINARY CONSIDERATIONSSTEP 2If a fixing screw is used to secure the front cover, turn the screw 3 full turnsin the counterclockwise direction. With the screw now loosened, press it into release the front cover.If a screw is not used, press the tab located behind the screw hole. The frontcover can now be removed.PC BOARD REMOVALSTEP 3Loosen the holding screw located on the right side of the PCB and slide the PCBup until the screw enters the widened region. The PCB can now be lifted off.MOUNTINGSTEP 4The COSMOS DT can be mounted either on flat surface or at corner.a. Open the knockout holes on the rear cover.b. Insert the cable through the cable hole.c. Mount the rear cover in its final location.d. Seal the remaining holes with sealant.e. After mounting the back cover replace the PCB in its position.PC BOARD ADJUSTMENTSTEP 5After the Detector base has been mounted, reinstall the PCB. Use the scaleon the bottom left side of the PCB to choose the correct vertical adjustmentposition as follows:For WIDE ANGLE LENS RK210/RK 215installed at a height of 2.5m (8’2”) (for UL).Fine Tuning of Protected Area:Slide the board up - to  lower the beams and reduce the range.Slide the board down - to  raise the beams and increase the range.For LONG RANGE: Select select position, LONG, Pulse Count of 1 and amounting height of 2.5m.When completed, fasten the screw to secure the PCB in the desired position.RK-225 install at 2m (6’7”) at Long position onlySCALE POSITIONshortlongROOM SIZE3-6m (9-18ft)6-15m (18-50ft)3PRELIMINARY CONSIDERATIONSSTEP 1•Dual IR and MW Technologies•Creep Zone•Microprocessor Design•Automatic True Temperature Compensation•Microwave Range Adjustment•Pigmented Lenses•Alternate Polarity Pulse Count•Low Current Consumption•High RFI Immunity•Anti-Fluorescent Interference Signal Processing•Wall and Corner Mounting Without Accessories•Vertical Adjustment•UL Listed VersionsCOSMOS DT FEATURESWhen LEDS Jumper is IN:•YELLOW LED indicates PIR detection•GREEN LED indicates MW detection•RED LED indicates alarm(simultaneous PIR and MW detection)•At Powe-up period, the Leds will blink continuously, one after the other, untill end of warm-up period.LED displayTAMPER+        - LEDS ON ALARM C29+MU1+5VIFGNDGNDS11 T4C19C6C25C8LONGSHORT MICROWAVESENSITIVITYMIN MAXC24 C21C1PULSEOFFTC1XTL1C28C15Before installation, carefully study the space to be protected so as to choosethe correct placement of the unit and lens for best coverage.The detector should be installed so that the beam patterns are at 45º(optimal) to the intruder's expected path. Corner installations arerecommended. Installation height should be between 1.8m (5’9”) and 2m(6’7”) for the 225 and at an optional 2.5m (8’2”) for the RL-17. Use Fig 3as reference.INSTALLATIONThe IR range is determined by the installation height. Use fig 3 as areference. For every 10cm (4") of lowering (or increasing) theinstallation height, the range is reduced (or increased) by 2.8m (9'2").NOTE2Fig 1.
The pigmented lens is attached to the inside of the front plastic cover usinga sensor protective sleeve.1. Remove the sensor protecting sleeve by pushing up the clip that holds the top part of the sleeve to the front cover.2. Disconnect the lens from the sleeve by gently lifting it from the holding pins that secure it to the sides of the sleeve.3. Select the desired lens and make sure that the cut corners are pointed upwards. (Fig. 4).4. Place the two pins, located on the top and bottom part of the lens, into the matching holes on the sleeve.5. Place the holes on either side of the lens into their matching holding pinson the sides of the sleeve.6. Insert the protective sleeve back into place on the front cover.ROKONET LIMITED WARRANTYRokonet Electronics, Ltd. and its subsidiaries and affiliates("Seller") warrants its products to be free from defects inmaterials and workmanship under normal use for 24 monthsfrom the date of production. Because Seller does not installor connect the product and because the product may beused in conjunction with products not manufactured by theSeller, Seller can not guarantee the performance of thesecurity system which uses this product. Sellers obligationand liability under this warranty is expressly limited torepairing and replacing, at Sellers option, within areasonable time after the date of delivery, any product notmeeting the specifications. Seller makes no other warranty,expressed or implied, and makes no warranty ofmerchantability or of fitness for any particular purpose. Inno case shall seller be liable for any consequential orincidental damages for breach of this or any other warranty,expressed or implied, or upon any other basis of liabilitywhatsoever.Sellers obligation under this warranty shall not include anytransportation charges or costs of installation or any liabilityfor direct, indirect, or consequential damages or delay.Seller does not represent that its product may not becompromised or circumvented; that the product will preventany persona; injury or property loss by burglary, robbery,fire or otherwise; or that the product will in all cases provideadequate warning or protection. Buyer understands that aproperly installed and maintained alarm may only reducethe risk of burglary, robbery or fire without warning, but isnot insurance or a guaranty that such will not occur or thatthere will be no personal injury or property loss as a result.Consequently seller shall have no liability for any personalinjury, property damage or loss based on a claim that theproduct fails to give warning. However, if seller is held liable,whether directly or indirectly, for any loss or damage arisingfrom under this limited warranty or otherwise, regardless ofcause or origin, sellers maximum liability shall not exceedthe purchase price of the product, which shall be completeand exclusive remedy against seller.No employee or representative of Seller is authorized tochange this warranty in any way or grant any otherwarranty.WARNING: This product should be tested at least once aweek.PROCEDURE FOR CHANGING LENSESFig 4.Lens ChangeProcedureTERMINAL WIRINGSTEP 6Wire cable to the terminal block at the top of the PCB as follows:12 VDC: Power supply input.ALARM: Normaly closed output.TAMPER: Normaly closed dry output.LEDS: IN - Enables all LEDsOUT - Disables all LEDsPULSE: IN - NO Pulse Count (1 pulse)OUT -Alternative Polarity Pulse Count (2 pulses)The COSMOS DT has two jumpers that can be either IN (used) orOUT (unused).Unused jumpers should be placed on one leg only to prevent their loss.JUMPER SETTINGSTEP 7WALK TESTSTEP 8Two minutes after applying power (a warm-up period), walk test the detectorover the entire protected area to verify proper operation of the unit.The RK-225 needs a longer warm-up period of FOUR minutes. It enables apowerful long range sensing capability and has increased sensitivity.Fig 2: Jumper positions.4IN OUTNOTE•Make sure to replace front cover before Walk Test.•The MW range can be adjusted using the potentiometer located at thebottom of the PCB. It is important to set the potentiometer to the lowestpossible setting that will still provide coverage for the entireprotected area.FINAL SETUPSTEP 9After completing the installation and testing stages, ensure all jumpersare at their desired positions. The unit is now ready for normal use.TOP VIEW SIDE VIEWFig 3: Cosmos DT Lenses5SPECIFICATIONSELECTRICALCurrent consumption: 19mA at 12 VDC45mA at 16 VDC(MAX with all LED's ON)Voltage requirements: 9-16 VDC regulatedAlarm contacts:  24 VDC, 50 mATamper contacts: 24 VDC, 0.1AOPTICALFiltering: White Light ProtectionPHYSICALSize: 127.6 x 64.2 x 40.9mm(5 x 2.5 x 1.6 in.)ENVIRONMENTALOperating temperature: -10ºC to 55ºC (14ºF to 131ºF)Storage Temperature: -20ºC to 60ºC (-4ºF to 140ºF)1. The models have been listed by Underwriters Laboratories for use with the wide angle lens only .2. The detector is intended to be connected to a listed burglar alarm control unit capable of providing 4 hours of standby power.Specifications are subject to change without priornotice. Should any questions arise, contact yourdistributor.NOTES FOR UL6ROKONET ELECTRONICS LTD.14 HACHOMA ST.75655 RISHON LETZION. ISRAEL.TEL: (972) 3 961 6555  FAX: (972) 3 961 65845IN215© 2001 Rokonet Electronics Ltd06/01TEL: 1 914TEL: 44 (0)TEL: 33 (0)TEL: 39 (02)TEL: 55 (21)FAX: 1 914FAX: 44 (0)FAX: 33 (0)FAX: 39 (02)FAX: 55 (21)ROKONET USA:ROKONET UK:ROKONET FRANCE:ROKONET ITALY:ROKONET BRAZIL:592 10681527 576 765155 1233903925 354496.3544592 12711527 576 816148 8630423925 131496.3547COSMOSDT SERIESRK-210,215,225INSTALLATIONINSTRUCTIONSThis equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to part 15 of the FCC Rules. These limitsare designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference willnot occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined byturning the equipment on and off, the user is encouraged to try to correctthe interference by one or more of the following measures:•Reorient or relocate the receiving antenna•Increase the separation between the equipment and the receiver•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected•Consult the dealer or an experienced radio/TV technician for help.Changes or modifications to this equipment not expressly approved bythe party responsible for compliance (Rokonet Electronics Ltd.) could void the user's authority to operate the equipment.NOTEWIDE ANGLE (RL-115)RK-210/215CORRIDOR (RL-15)RK-210/2152.5m(8'2")0.4m(1'4") 2.5m(8'2") 10m/15m(33/49')1.1m(3'3")2.5m(8'2")0.4m(1'4") 2m(6'7") 5m(16'5") 10m/15m(33/49')WIDE ANGLERK-225 RL-125LONG RANGERK-225 (RL-17)833m2.5m(8'2")0.4m(1'4") 4m(13'1") 23m(75'5")1.1m(3'3")2m(6'7")0.4m(1'4") 3m(9'10") 25m(82')1.1m(3'3")1101.3m/2mTOP VIEW SIDE VIEW

Navigation menu