Riso Kagaku RFR6 RFID Tag Reader/Writer User Manual

Riso Kagaku Corporation RFID Tag Reader/Writer Users Manual

Users Manual

1
RF-MODULE-V6 (Model: 050-34901)
User’s Manual
Ver. 1.0
Riso Kagaku Corporation
2
This manual describes the use, the functions and the performance of the Radio
Frequency Identification System RF-MODULE-V6(Model: 050-34901). The
system is so manufactured that it can not be repaired or replaced by the user;
and therefore, if there are such needs, please contact Riso Kagaku Corporation
or its agent. No service work should be started before the service person has
read this manual.
Features
This product uses radio frequency of 13.56 MHz to communicate with the tags
or cards; thus, it should conform to any relative laws and regulations of the
country or the region.
Cautions
1. Use or store this product on the temperature and humidity conditions
mentioned below, so as to maintain its operational reliability.
2. Use or store this product in an environment free of explosive gases,
inflammable gases, corrosive gases, oils, organic solvents, dust, salt and
metal powders.
3. Keep this product free of direct shock, strong vibration or sunshine.
4. To communicate with the tags or cards, this product uses 13.56 MHz radio
frequency, which may be interfered by radio waves (noises) emitted from a
transceiver, a motor, a monitor, a power supply (including a power supply
IC), etc. Please make sure that such interferences will not occur before using
the product in a place near to these devices.
5. Take proper measures to avoid any possible electrostatic discharge to the
product, which may damage the product.
6. After doing the wiring, make sure the connectors are fastened properly.
Warning
Do not alter any part of the product.
Alteration of the printed wiring board, the antennas or the connecting cables of
the module may damage the control board of the printer, and is an illegal act if
it causes the modular transmitter emissions out of the limits provided by laws
or regulations.
3
Specifications
Dimensions Less than φ32mm×18mm
Transmitting Frequency 13.56 MHz
Transmission field strength Less than 500 µV/m at 3m
Operating Temperature 0 to +40
oC
Storage Temperature -20 to +60
oC
Operating Humidity 25 to 85% RH (Without condensation)
Supply voltage 5 V dc +/- 10%
Discarding the Product
The product should be discarded as normal printed wiring boards. If you do
not know how such boards should be discarded, ask Riso Kagaku Corporation,
its agent or the government.
Pin Assignments
PIN No. Description
1 RUN Module running signal
(VIH:2.66V(min),VIL:0.66V(max))HI ACTIVE
2 /RESET
Device Reset.
(VIH:2.66V(min),VIL:0.66V(max))LO ACTIVE
3 RXD Recirve data (HOST to MODULE)
(VIH:2.66V(min),VIL:0.66V(max))
4 TXD Transfar data (Module to HOST)
(VIH:2.66V(min),VIL:0.66V(max))
5 GND Ground.
6 VCC +5V DC±5%(4.5V – 5.5V)
Connector: BM06B-SRSS-TBT-LF-SNJST
Connecting
4
Host Interface
Protocol: ASYNC(3.3V CMOS )
Baud rate:38400bps
Data length:8 bit
Parity : None
Stop bit: 1 bit
Hnad Shaking: None
Voltage level : CMOS (VIH:2.66V(min),VIL:0.66V(max))
Sample Application
1) "UIDRD" on desktop is double-clicked.
Double click
2) The execution screen is displayed.
5
3) When "UIDREAD" button is pushed, UID of tag is read.
Push
Notice about the law and the standard
FCC ID: RPARFR6
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
The user is cautioned that unauthorized changes or modifications not approved
could void the user's authority to operate the equipment.
IC: 4819A-RFR6
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Display
Reading Data
Displa
y
UID
Data

Navigation menu