Rixson 2700HM (05 09) Floor Closer Installation Instructions

User Manual: Rixson 2700HM Floor Closer Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 2

Installation Instructions
2700HM (05-09)
HM27 Floor Closer
3/4” Offset Pivoted – Handed
Closing speeds can be adjusted to suit local conditions and
requirements. Label on closer face designates the purpose
of each adjustment screw. Adjustments are for speed
control.
A. The Delay Action valve allows adjustment from full
open to 65° closed position. (Optional)
B. The Closing Speed valve allows adjustment from full
open to 15° on units without the Delay Action feature.
C. The Closing Speed valve allows adjustment from 65°
to 15° closed position on closers with Delay Action
feature.
D. Latch valve allows adjustment from 15° to closed
position.
E. Important: Backcheck adjustment must be adjusted to
vary resistance from light to firm at 60° of door open.
Do not use Backcheck as deadstop. This is an intensity
valve not speed control.
RIXSON FIREMARK
FRANKLIN PARK ILLINOIS
LH
S
L
O
W
L
A
T
C
H
D
E
L
A
Y
A
C
T
I
O
N
S
L
O
W
C
L
O
S
I
N
G
S
P
E
E
D
T
U
R
N
F
U
L
L
1
8
0
°
O
N
H
O
O
F
F
B
A
C
K
C
H
E
C
K
+-
RIXSON FIREMARK
FRANKLIN PARK ILLINOIS
RH
S
L
O
W
L
A
T
C
H
D
E
L
A
Y
A
C
T
I
O
N
S
L
O
W
C
L
O
S
I
N
G
S
P
E
E
D
B
A
C
K
C
H
E
C
K
+
-
This Set Screw Is On Selector Hold-open Types Only
Closer Adjustment
9-7/8 Floor Plate
9-13/16 Cement Case
Floor Plate
3/4
Arm
2-1/16 R.
Jamb
Bevel Edge
of Door
1/8” in 2”
3/16 R.
13/16
3/4 1/8 Min. Clearance Required
Between Door and Stop
2-1/16
1-3/16
4-1/16
6-1/8
Floor
Plate
5-7/8
Cement
Case
Drill (3) 3/8” Dia. Clearance Holes
in Door for Arm Screws.Mounting
1-1/4
WITH THRESHOLD
Set Cement Case Flush
with Finished Floor
3/16
3/4
WITH FLOOR PLATE
Set Cement Case 1/8" Below
Surface of Finished Floor
Cement Case
3/16
Floor
Plate
1/2
1/2” Threshold
1-1/8
Right Hand Shown
Conversion from inches
to metric: inch x 25.4
Template
PAGE 4
T
U
R
N
F
U
L
L
1
8
0
°
CLOSED
70°
15°
D
E
L
A
Y
E
D
A
C
T
I
O
N
I
f
e
q
u
i
p
p
e
d
3/4
3/4
2-3/8
4”
1”
3 Holes for
2-1/8 x 1/4-20 RHMS
3/4
1-1/8
Offset Hinge 1-1/2
Pai Per Doorr
4-1/2
1/2
1/2
1-1/8 1-1/8
1” 3/8
2-1/4
13/16 11/16 3/4
1-3/4
1/4 1/16
.134 1/16
3°-30’ or 1/8” in 2” Bevel
For Bevel Edge Doors Only
O
F
F
H
O
O
N
ASSA ABLOY
RIXSON®
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
RIXSON®
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
PAGE 3
PAGE 2
How To Determine
Hand of Door
LH RH
Face a door swinging open away from you. If it opens to the
right, it is right hand. If it opens to the left, it is left hand.
Arm Cap
RIGHT HAND installation
Spindle Arm
Arm Locking Set Screw
5/8-18UNF x 1” LG
Installation Instructions
1. Install Closer
Door Stop
1/8” Minimum From
Face of Door to Door Stop
Right Hand Door
Spindle Position
3/4” From Face
of Door to C of Spindle
L
13/16” From Face of
Jamb to C of Spindle
L
Door
Jamb
A. Measure 13/16” out from door jamb.
B. Allow 1/8” minimum clearance from door stop to door
face. Measure door thickness. Add 3/4”.
C. Where lines meet determines center line of closer.
2. Install Cement Case in Floor
A. For floor plate application: Cement case is set 1/8”
(3.2mm) below floor level.
B. For threshold application: Cement case is set flush with
floor.
C. Set cement case in floor and block in position.
D. Case should be parallel with center line of door.
E. Use Quick Spotter, furnished with closer, to locate closer.
F. Grout in cement case with closer. Cement should not get
between closer and case.
3. Hang Door
4. Attach Closer Arm
CAUTION: Closer is shipped with “Stroke” valve down.
DO NOT FORCE VALVE DOWN.
A. Turn spindle until wrench is parallel with center line
of closer.
B. Slip arm on spindle and spot arm mounting holes.
C. Drill three (3) 3/8” diameter holes in door for arm
mounting screws.
D. Attach arm as shown.
E. Open Closing Speed and Latch Speed valves
(counterclockwise) one turn. Door will then close.
Pins point down for
RH closer
Wrench
Right Hand Shown
LEVEL IN BOTH
DIRECTIONS
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department