PAGE 4

Closer Adjustment

BA

CLOS

DELAY

Template

+

S LO W

C
C K HE

-

TU

F HO ON
OF
RN

FULL 1

13/16
3/4

1/8 Min. Clearance Required
Between Door and Stop

3/16 R.

This Set Screw Is On Selector Hold-open Types Only

Do not use Backcheck as deadstop. This is an intensity
valve not speed control.

1”

DELA
YED

Arm

3°-30’ or 1/8” in 2” Bevel
1/16
1/4 1/16
1-3/4

2-1/4
3/8
11/16

3/4

For Bevel Edge Doors Only

6-1/8
Floor
Plate

Floor Plate

2-1/16 R.

9-13/16 Cement Case
9-7/8 Floor Plate
Offset Hinge 1-1/2
Pair Per Door

Drill (3) 3/8” Dia. Clearance Holes
in Door for Arm Mounting Screws.

2-1/16

70°

C. The Closing Speed valve allows adjustment from 65°
to 15° closed position on closers with Delay Action
feature.

1/2
1-1/8

5-7/8
Cement
Case

Jamb

AC
TI
ON
ped
uip
eq
If

B. The Closing Speed valve allows adjustment from full
open to 15° on units without the Delay Action feature.

.134

13/16

Bevel Edge
of Door
1/8” in 2”

3/4

A. The Delay Action valve allows adjustment from full
open to 65° closed position. (Optional)

4-1/2

1/2
1-1/8

°
80

TU

RH

2700HM (05-09)

S LO W

F

Closing speeds can be adjusted to suit local conditions and
requirements. Label on closer face designates the purpose
of each adjustment screw. Adjustments are for speed
control.

Installation Instructions

CK

S LO W

IN

G S PE

ATCH

3/4” Offset Pivoted – Handed

ED

-

ED

FULL 1

+

IN

G S PE

ACTI

HM27 Floor Closer

ASSA ABLOY

FRANKLIN PARK ILLINOIS

°
80

RN

HO O F

C
C K HE

CK

BA

S LO W

CLOS

DELAY

L

ACTI

ON

ATCH

ON

LH

ON

RIXSON FIREMARK

FRANKLIN PARK ILLINOIS

L

RIXSON FIREMARK

RIXSON

®

3/4
15°

D. Latch valve allows adjustment from 15° to closed
position.

1-1/8
1-3/16

CLOSED

3/16

E. Important: Backcheck adjustment must be adjusted to
vary resistance from light to firm at 60° of door open.

4-1/16
1/2” Threshold

WITH THRESHOLD
Set Cement Case Flush
with Finished Floor

4”
2-3/8
3/4
1”

3/4
3/4
1-1/8

3 Holes for
2-1/8 x 1/4-20 RHMS
1-1/4

1/2

3/16
Floor
Plate

RIXSON
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

Rixson Specialty Door Controls

www.rixson.com

®

Right Hand Shown
Conversion from inches
to metric: inch x 25.4

Cement Case
WITH FLOOR PLATE
Set Cement Case 1/8" Below
Surface of Finished Floor

ASSA ABLOY

866-474-9766 Technical Department

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department

PAGE 3

PAGE 2

3. Hang Door

How To Determine
Hand of Door
LH

Arm Locking Set Screw
5/8-18UNF x 1” LG

RH

4. Attach Closer Arm
CAUTION:
Spindle Arm

Arm Cap

Pins point down for
RH closer

Closer is shipped with “Stroke” valve down.
DO NOT FORCE VALVE DOWN.

A. Turn spindle until wrench is parallel with center line
of closer.
Wrench

Face a door swinging open away from you. If it opens to the
right, it is right hand. If it opens to the left, it is left hand.

B. Slip arm on spindle and spot arm mounting holes.
C. Drill three (3) 3/8” diameter holes in door for arm
mounting screws.

RIGHT HAND installation

Installation Instructions

Right Hand Shown

D. Attach arm as shown.
E. Open Closing Speed and Latch Speed valves
(counterclockwise) one turn. Door will then close.

1. Install Closer
Door Stop
1/8” Minimum From
Face of Door to Door Stop
Door
Jamb

Right Hand Door
3/4” From Face
of Door to CL of Spindle

A. Measure 13/16” out from door jamb.
B. Allow 1/8” minimum clearance from door stop to door
face. Measure door thickness. Add 3/4”.
C. Where lines meet determines center line of closer.

Spindle Position
13/16” From Face of
Jamb to CL of Spindle

2. Install Cement Case in Floor

LEVEL IN BOTH
DIRECTIONS

Rixson Specialty Door Controls

A. For floor plate application: Cement case is set 1/8”
(3.2mm) below floor level.
B. For threshold application: Cement case is set flush with
floor.
C. Set cement case in floor and block in position.
D. Case should be parallel with center line of door.
E. Use Quick Spotter, furnished with closer, to locate closer.
F. Grout in cement case with closer. Cement should not get
between closer and case.

www.rixson.com

866-474-9766 Technical Department

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : AdobePS5.dll Version 5.0.1
Modify Date                     : 2009:05:28 13:25:35-04:00
Create Date                     : 2009:05:28 13:25:17-04:00
Metadata Date                   : 2009:05:28 13:25:35-04:00
Format                          : application/pdf
Title                           : 2700HM (05-09).cdr
Document ID                     : uuid:3c6a7660-ac9a-441f-8016-bececb6d85dd
Instance ID                     : uuid:94e9e2ea-ec86-482e-8e2a-08411032652d
Page Count                      : 2
Creator                         : AdobePS5.dll Version 5.0.1
EXIF Metadata provided by EXIF.tools

Navigation menu