Rixson 2700HM (05 09) Floor Closer Installation Instructions
User Manual: Rixson 2700HM Floor Closer Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
PAGE 4 Closer Adjustment BA CLOS DELAY Template + S LO W C C K HE - TU F HO ON OF RN FULL 1 13/16 3/4 1/8 Min. Clearance Required Between Door and Stop 3/16 R. This Set Screw Is On Selector Hold-open Types Only Do not use Backcheck as deadstop. This is an intensity valve not speed control. 1” DELA YED Arm 3°-30’ or 1/8” in 2” Bevel 1/16 1/4 1/16 1-3/4 2-1/4 3/8 11/16 3/4 For Bevel Edge Doors Only 6-1/8 Floor Plate Floor Plate 2-1/16 R. 9-13/16 Cement Case 9-7/8 Floor Plate Offset Hinge 1-1/2 Pair Per Door Drill (3) 3/8” Dia. Clearance Holes in Door for Arm Mounting Screws. 2-1/16 70° C. The Closing Speed valve allows adjustment from 65° to 15° closed position on closers with Delay Action feature. 1/2 1-1/8 5-7/8 Cement Case Jamb AC TI ON ped uip eq If B. The Closing Speed valve allows adjustment from full open to 15° on units without the Delay Action feature. .134 13/16 Bevel Edge of Door 1/8” in 2” 3/4 A. The Delay Action valve allows adjustment from full open to 65° closed position. (Optional) 4-1/2 1/2 1-1/8 ° 80 TU RH 2700HM (05-09) S LO W F Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. Installation Instructions CK S LO W IN G S PE ATCH 3/4” Offset Pivoted – Handed ED - ED FULL 1 + IN G S PE ACTI HM27 Floor Closer ASSA ABLOY FRANKLIN PARK ILLINOIS ° 80 RN HO O F C C K HE CK BA S LO W CLOS DELAY L ACTI ON ATCH ON LH ON RIXSON FIREMARK FRANKLIN PARK ILLINOIS L RIXSON FIREMARK RIXSON ® 3/4 15° D. Latch valve allows adjustment from 15° to closed position. 1-1/8 1-3/16 CLOSED 3/16 E. Important: Backcheck adjustment must be adjusted to vary resistance from light to firm at 60° of door open. 4-1/16 1/2” Threshold WITH THRESHOLD Set Cement Case Flush with Finished Floor 4” 2-3/8 3/4 1” 3/4 3/4 1-1/8 3 Holes for 2-1/8 x 1/4-20 RHMS 1-1/4 1/2 3/16 Floor Plate RIXSON Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Rixson Specialty Door Controls www.rixson.com ® Right Hand Shown Conversion from inches to metric: inch x 25.4 Cement Case WITH FLOOR PLATE Set Cement Case 1/8" Below Surface of Finished Floor ASSA ABLOY 866-474-9766 Technical Department Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department PAGE 3 PAGE 2 3. Hang Door How To Determine Hand of Door LH Arm Locking Set Screw 5/8-18UNF x 1” LG RH 4. Attach Closer Arm CAUTION: Spindle Arm Arm Cap Pins point down for RH closer Closer is shipped with “Stroke” valve down. DO NOT FORCE VALVE DOWN. A. Turn spindle until wrench is parallel with center line of closer. Wrench Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. B. Slip arm on spindle and spot arm mounting holes. C. Drill three (3) 3/8” diameter holes in door for arm mounting screws. RIGHT HAND installation Installation Instructions Right Hand Shown D. Attach arm as shown. E. Open Closing Speed and Latch Speed valves (counterclockwise) one turn. Door will then close. 1. Install Closer Door Stop 1/8” Minimum From Face of Door to Door Stop Door Jamb Right Hand Door 3/4” From Face of Door to CL of Spindle A. Measure 13/16” out from door jamb. B. Allow 1/8” minimum clearance from door stop to door face. Measure door thickness. Add 3/4”. C. Where lines meet determines center line of closer. Spindle Position 13/16” From Face of Jamb to CL of Spindle 2. Install Cement Case in Floor LEVEL IN BOTH DIRECTIONS Rixson Specialty Door Controls A. For floor plate application: Cement case is set 1/8” (3.2mm) below floor level. B. For threshold application: Cement case is set flush with floor. C. Set cement case in floor and block in position. D. Case should be parallel with center line of door. E. Use Quick Spotter, furnished with closer, to locate closer. F. Grout in cement case with closer. Cement should not get between closer and case. www.rixson.com 866-474-9766 Technical Department Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : AdobePS5.dll Version 5.0.1 Modify Date : 2009:05:28 13:25:35-04:00 Create Date : 2009:05:28 13:25:17-04:00 Metadata Date : 2009:05:28 13:25:35-04:00 Format : application/pdf Title : 2700HM (05-09).cdr Document ID : uuid:3c6a7660-ac9a-441f-8016-bececb6d85dd Instance ID : uuid:94e9e2ea-ec86-482e-8e2a-08411032652d Page Count : 2 Creator : AdobePS5.dll Version 5.0.1EXIF Metadata provided by EXIF.tools