PAGE 4

Closer Adjustment

BA

DELAY
CLOS

DELAY

L

CLOS

Template
4-1/4
3-55/64
2-45/64

S LO W

+

S LO W

FULL 1

C
C K HE

CK

-

TU

F HO ON
OF
RN

FULL 1

13/16
3/4

°
80

TU

RH

Do not use Backcheck as deadstop. This is an intensity
valve not speed control.

Bevel Edge
of Door
1/8” in 2”

Arm

5-7/8
Cement
Case

Jamb

DELA
YED

AC
TI
ON

1/8 R.

5/8
7/16
3/4

3/4
13/16

3/4

C
L

1/4

2-1/16

3/4

3/4
1-1/8

Door Mortised
5/16 Deep
for Arm

1-1/4
15°

D. Latch valve allows adjustment from 15° to closed
position.

11/16
3/16

1-5/16

CLOSED

E. Important: Backcheck adjustment must be adjusted to
vary resistance from light to firm at 60° of door open.

5-3/8

WITH FLOOR PLATE
Set Cement Case 1-1/4”
Below Surface of Finished Floor
Bevel Heel Edge of Door
1/8 in 2
5/16
13/16

12-1/8

Closer Removal or Reinstallation
4”

Before removing or installing closer, close down valve screws. When reinstalling, lock closer in hold-open position if
provided.
Closer Removal:
1. Remove thru-bolts, arm cap and loosen arm locking screw.
2. Open door to hold-open or (approx.) 90° and close. (If non hold-open is being removed, insert a flat blade (10” min) screwdriver
between spindle and torque washer to prevent spindle from turning.)
3. Remove arm, shim and torque washer from spindle.
4. With door open, remove threshold.
5. Remove closer mounting screws (4) and slide closer out under door.

3/4
2-1/4

3/4

3/4

3/4
3 Holes for
1/4”-20 x 2-1/8” Long
Truss Head Machine Screw

1-7/16
1-15/16

1-1/4

Door Leaf
3/8

2-1/2

Conversion from inches to metric: inch x 25.4

RIXSON
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

www.rixson.com

1”

2-3/8

1/4

5/16
3/16 R.
1/8 Min.
Clearance

Jamb Leaf
1-1/8
7/16
1-17/32

Right Hand Shown

Closer Reinstallation:
Reverse above procedure when reinstalling closer.
Before attaching arm, closer spindle must be in hold-open or rotated to 90°.
Non hold-open closers will require the use of a flat blade (10” min.) screwdriver
For rotating the spindle.

Rixson Specialty Door Controls

Holes for
1/4-20x5/8" FHMS or
#14x1-1/2" FHWS
1/4

1/16
Drill (3) 3/8” Dia. Clearance Holes
in Door for Arm Mounting Screws.

70°

C. The Closing Speed valve allows adjustment from 65°
to 15° closed position on closers with Delay Action
feature.

2

9-13/16 Cement Case
10-7/8 Floor Plate
ped
uip
eq
If

B. The Closing Speed valve allows adjustment from full
open to 15° on units without the Delay Action feature.

Floor Plate

2-1/16 R.

23/64
45/64
1-1/16

Bevel Edge
of Door
1/8 in 2

6-1/8
Floor
Plate

3/4

A. The Delay Action valve allows adjustment from full
open to 65° closed position. (Optional)

180 Top Pivot

3/8
1-35/64
25/64
Jamb

1/8 Min. Clearance Required
Between Door and Stop

3/16 R.

This Set Screw Is On Selector Hold-open Types Only

Closing speeds can be adjusted to suit local conditions and
requirements. Label on closer face designates the purpose
of each adjustment screw. Adjustments are for speed
control.

2700Q (05-09)

ED

S LO W

IN

G S PE

27Q Removable Floor Closer
With Floor Plate
3/4” Offset Pivoted – Handed
Installation Instructions

ASSA ABLOY

FRANKLIN PARK ILLINOIS
ATCH

°
80

RN

-

IN

G S PE

ED

HO O F
F
ON

C
C K HE

CK

BA

S LO W

ACTI

ON

ACTI

ON

LH

+

RIXSON FIREMARK

FRANKLIN PARK ILLINOIS
ATCH

L

RIXSON FIREMARK

RIXSON

®

®

ASSA ABLOY

866-474-9766 Technical Department

Where vertical adjustment is necessary,
two (2) 1/16” thick shims are provided to be
placed between arm and torque washer.
Rixson Specialty Door Controls

www.rixson.com

3-9/16
4-5/8
5”
5/16

13/16

2-1/2

3-15/32
4-9/16

1-1/8

13/16

5”

5/16

1-1/8
4-1/4
866-474-9766 Technical Department

PAGE 3

PAGE 2

How To Determine
Hand of Door
LH

Top Pivot Jamb Portion

IMPORTANT:

Top Pivot Door Portion

Use plumb line to make
sure that center line of
top pivot pin lines up
with center line of closer
spindle.

RH
Intermediate Pivot
(Side Jamb)

Arm Cap

4. Hang Door
CAUTION:

2
2
1
3

Spindle Arm
Knuckle

A. Remove styrofoam and metal plate from closer.
1

B. Attach top pivot and closer arm to door.

3
C. Attach top pivot to frame.
D. Place closer in hold-open position or turn closer
spindle to 90 position.

Face a door swinging open away from you. If it opens to the
right, it is right hand. If it opens to the left, it is left hand.

Arm Locking Set Screw
5/8-18UNF x 1” LG

E. Set door on closer spindle. Do not attempt to close
the door.

RIGHT HAND installation

F.

Installation Instructions
1. Install Closer

2. Install Cement Case in Floor

Spacer Block
(Typ. Two)

LEVEL IN BOTH
DIRECTIONS

1/8” Minimum From
Face of Door to Door Stop

Right Hand Door
3/4” From Face
of Door to CL of Spindle
Spindle Position
13/16” From Face of
Jamb to CL of Spindle

A. Measure 13/16” out from door jamb.
B. Allow 1/8” minimum clearance from door stop to door
face. Measure door thickness. Add 3/4”.
C. Where lines meet determines center line of closer.

Push item 1 “top pivot pin” into place. Attach “cap”
item 3. (Illustration) CAP MUST BE TIGHTENED
SECURELY.

G. Install intermediate pivots. (See intermediate pivot
template)
H. Open Closing Speed and Latch valves
(counterclockwise) one turn. Door will then close.

Door Stop

Door
Jamb

Closer is shipped with “valve” screws down.
DO NOT FORCE VALVE DOWN.

I.

While working door back and forth TIGHTEN ARM
LOCKING SCREW SECURELY with wrench
furnished.

J.

Put arm cap on arm and secure TIGHTLY with cap
screw furnished.

K. Insert spacer blocks as shown and attach floor plate.
A. For floor plate application: Cement case is set 1-1/4”
below floor level.
B. Set cement case with styrofoam and closer attached in
floor and block in position.
C. Case should be parallel with center line of door.
D. CEMENT CASE SHOULD BE LEVEL. Place levels per
illustration.
E. Grout in cement case with closer and styrofoam
attached. Cement should not get between closer and
case.

3. Install Top Pivot & Closer Arm
A. Install top pivot in door per template.
B. Install top pivot in frame per template.
C. Center line of pivot should line up with center line of
closer. Use plumb line as illustrated.
D. See template for intermediate pivot. Use one pivot for
doors up to 250 lbs. Use two pivots for doors between
250 and 400 lbs.

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : AdobePS5.dll Version 5.0.1
Modify Date                     : 2009:05:28 13:18:39-04:00
Create Date                     : 2009:05:28 13:18:07-04:00
Metadata Date                   : 2009:05:28 13:18:39-04:00
Format                          : application/pdf
Title                           : 2700Q (05-09).cdr
Document ID                     : uuid:c10efe46-3d13-4d3f-8797-190107635cda
Instance ID                     : uuid:2d61d22a-65ec-4865-bc93-3641cf956f28
Page Count                      : 2
Creator                         : AdobePS5.dll Version 5.0.1
EXIF Metadata provided by EXIF.tools

Navigation menu