Rixson 2700Q (05 09) Removable Floor Closer With Plate Installation Instructions
User Manual: Rixson 2700Q Removable Floor Closer with Floor Plate Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
PAGE 4 Closer Adjustment BA DELAY CLOS DELAY L CLOS Template 4-1/4 3-55/64 2-45/64 S LO W + S LO W FULL 1 C C K HE CK - TU F HO ON OF RN FULL 1 13/16 3/4 ° 80 TU RH Do not use Backcheck as deadstop. This is an intensity valve not speed control. Bevel Edge of Door 1/8” in 2” Arm 5-7/8 Cement Case Jamb DELA YED AC TI ON 1/8 R. 5/8 7/16 3/4 3/4 13/16 3/4 C L 1/4 2-1/16 3/4 3/4 1-1/8 Door Mortised 5/16 Deep for Arm 1-1/4 15° D. Latch valve allows adjustment from 15° to closed position. 11/16 3/16 1-5/16 CLOSED E. Important: Backcheck adjustment must be adjusted to vary resistance from light to firm at 60° of door open. 5-3/8 WITH FLOOR PLATE Set Cement Case 1-1/4” Below Surface of Finished Floor Bevel Heel Edge of Door 1/8 in 2 5/16 13/16 12-1/8 Closer Removal or Reinstallation 4” Before removing or installing closer, close down valve screws. When reinstalling, lock closer in hold-open position if provided. Closer Removal: 1. Remove thru-bolts, arm cap and loosen arm locking screw. 2. Open door to hold-open or (approx.) 90° and close. (If non hold-open is being removed, insert a flat blade (10” min) screwdriver between spindle and torque washer to prevent spindle from turning.) 3. Remove arm, shim and torque washer from spindle. 4. With door open, remove threshold. 5. Remove closer mounting screws (4) and slide closer out under door. 3/4 2-1/4 3/4 3/4 3/4 3 Holes for 1/4”-20 x 2-1/8” Long Truss Head Machine Screw 1-7/16 1-15/16 1-1/4 Door Leaf 3/8 2-1/2 Conversion from inches to metric: inch x 25.4 RIXSON Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. www.rixson.com 1” 2-3/8 1/4 5/16 3/16 R. 1/8 Min. Clearance Jamb Leaf 1-1/8 7/16 1-17/32 Right Hand Shown Closer Reinstallation: Reverse above procedure when reinstalling closer. Before attaching arm, closer spindle must be in hold-open or rotated to 90°. Non hold-open closers will require the use of a flat blade (10” min.) screwdriver For rotating the spindle. Rixson Specialty Door Controls Holes for 1/4-20x5/8" FHMS or #14x1-1/2" FHWS 1/4 1/16 Drill (3) 3/8” Dia. Clearance Holes in Door for Arm Mounting Screws. 70° C. The Closing Speed valve allows adjustment from 65° to 15° closed position on closers with Delay Action feature. 2 9-13/16 Cement Case 10-7/8 Floor Plate ped uip eq If B. The Closing Speed valve allows adjustment from full open to 15° on units without the Delay Action feature. Floor Plate 2-1/16 R. 23/64 45/64 1-1/16 Bevel Edge of Door 1/8 in 2 6-1/8 Floor Plate 3/4 A. The Delay Action valve allows adjustment from full open to 65° closed position. (Optional) 180 Top Pivot 3/8 1-35/64 25/64 Jamb 1/8 Min. Clearance Required Between Door and Stop 3/16 R. This Set Screw Is On Selector Hold-open Types Only Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. 2700Q (05-09) ED S LO W IN G S PE 27Q Removable Floor Closer With Floor Plate 3/4” Offset Pivoted – Handed Installation Instructions ASSA ABLOY FRANKLIN PARK ILLINOIS ATCH ° 80 RN - IN G S PE ED HO O F F ON C C K HE CK BA S LO W ACTI ON ACTI ON LH + RIXSON FIREMARK FRANKLIN PARK ILLINOIS ATCH L RIXSON FIREMARK RIXSON ® ® ASSA ABLOY 866-474-9766 Technical Department Where vertical adjustment is necessary, two (2) 1/16” thick shims are provided to be placed between arm and torque washer. Rixson Specialty Door Controls www.rixson.com 3-9/16 4-5/8 5” 5/16 13/16 2-1/2 3-15/32 4-9/16 1-1/8 13/16 5” 5/16 1-1/8 4-1/4 866-474-9766 Technical Department PAGE 3 PAGE 2 How To Determine Hand of Door LH Top Pivot Jamb Portion IMPORTANT: Top Pivot Door Portion Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. RH Intermediate Pivot (Side Jamb) Arm Cap 4. Hang Door CAUTION: 2 2 1 3 Spindle Arm Knuckle A. Remove styrofoam and metal plate from closer. 1 B. Attach top pivot and closer arm to door. 3 C. Attach top pivot to frame. D. Place closer in hold-open position or turn closer spindle to 90 position. Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. Arm Locking Set Screw 5/8-18UNF x 1” LG E. Set door on closer spindle. Do not attempt to close the door. RIGHT HAND installation F. Installation Instructions 1. Install Closer 2. Install Cement Case in Floor Spacer Block (Typ. Two) LEVEL IN BOTH DIRECTIONS 1/8” Minimum From Face of Door to Door Stop Right Hand Door 3/4” From Face of Door to CL of Spindle Spindle Position 13/16” From Face of Jamb to CL of Spindle A. Measure 13/16” out from door jamb. B. Allow 1/8” minimum clearance from door stop to door face. Measure door thickness. Add 3/4”. C. Where lines meet determines center line of closer. Push item 1 “top pivot pin” into place. Attach “cap” item 3. (Illustration) CAP MUST BE TIGHTENED SECURELY. G. Install intermediate pivots. (See intermediate pivot template) H. Open Closing Speed and Latch valves (counterclockwise) one turn. Door will then close. Door Stop Door Jamb Closer is shipped with “valve” screws down. DO NOT FORCE VALVE DOWN. I. While working door back and forth TIGHTEN ARM LOCKING SCREW SECURELY with wrench furnished. J. Put arm cap on arm and secure TIGHTLY with cap screw furnished. K. Insert spacer blocks as shown and attach floor plate. A. For floor plate application: Cement case is set 1-1/4” below floor level. B. Set cement case with styrofoam and closer attached in floor and block in position. C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per illustration. E. Grout in cement case with closer and styrofoam attached. Cement should not get between closer and case. 3. Install Top Pivot & Closer Arm A. Install top pivot in door per template. B. Install top pivot in frame per template. C. Center line of pivot should line up with center line of closer. Use plumb line as illustrated. D. See template for intermediate pivot. Use one pivot for doors up to 250 lbs. Use two pivots for doors between 250 and 400 lbs. Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : AdobePS5.dll Version 5.0.1 Modify Date : 2009:05:28 13:18:39-04:00 Create Date : 2009:05:28 13:18:07-04:00 Metadata Date : 2009:05:28 13:18:39-04:00 Format : application/pdf Title : 2700Q (05-09).cdr Document ID : uuid:c10efe46-3d13-4d3f-8797-190107635cda Instance ID : uuid:2d61d22a-65ec-4865-bc93-3641cf956f28 Page Count : 2 Creator : AdobePS5.dll Version 5.0.1EXIF Metadata provided by EXIF.tools