Rixson 2700Q (05 09) Removable Floor Closer With Plate Installation Instructions

User Manual: Rixson 2700Q Removable Floor Closer with Floor Plate Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 2

Installation Instructions
2700Q (05-09)
27Q Removable Floor Closer
With Floor Plate
3/4” Offset Pivoted – Handed
Closing speeds can be adjusted to suit local conditions and
requirements. Label on closer face designates the purpose
of each adjustment screw. Adjustments are for speed
control.
A. The Delay Action valve allows adjustment from full
open to 65° closed position. (Optional)
B. The Closing Speed valve allows adjustment from full
open to 15° on units without the Delay Action feature.
C. The Closing Speed valve allows adjustment from 65°
to 15° closed position on closers with Delay Action
feature.
D. Latch valve allows adjustment from 15° to closed
position.
E. Important: Backcheck adjustment must be adjusted to
vary resistance from light to firm at 60° of door open.
Do not use Backcheck as deadstop. This is an intensity
valve not speed control.
Before removing or installing closer, close down valve screws. When reinstalling, lock closer in hold-open position if
provided.
Closer Removal:
Closer Reinstallation:
1. Remove thru-bolts, arm cap and loosen arm locking screw.
2. Open door to hold-open or (approx.) 90° and close. (If non hold-open is being removed, insert a flat blade (10” min) screwdriver
between spindle and torque washer to prevent spindle from turning.)
3. Remove arm, shim and torque washer from spindle.
4. With door open, remove threshold.
5. Remove closer mounting screws (4) and slide closer out under door.
Reverse above procedure when reinstalling closer.
Before attaching arm, closer spindle must be in hold-open or rotated to 90°.
Non hold-open closers will require the use of a flat blade (10” min.) screwdriver
For rotating the spindle.
RIXSON FIREMARK
FRANKLIN PARK ILLINOIS
LH
S
L
O
W
L
A
T
C
H
D
E
L
A
Y
A
C
T
I
O
N
S
L
O
W
C
L
O
S
I
N
G
S
P
E
E
D
T
U
R
N
F
U
L
L
1
8
0
°
O
N
H
O
O
F
F
B
A
C
K
C
H
E
C
K
+-
RIXSON FIREMARK
FRANKLIN PARK ILLINOIS
RH
S
L
O
W
L
A
T
C
H
D
E
L
A
Y
A
C
T
I
O
N
S
L
O
W
C
L
O
S
I
N
G
S
P
E
E
D
B
A
C
K
C
H
E
C
K
+
-
This Set Screw Is On Selector Hold-open Types Only
Closer Adjustment
Closer Removal or Reinstallation
10-7/8 Floor Plate
9-13/16 Cement Case
Floor Plate
3/4
Arm
2-1/16 R.
Jamb
Bevel Edge
of Door
1/8” in 2”
3/16 R.
13/16
3/4 1/8 Min. Clearance Required
Between Door and Stop
2-1/16
1-5/16
5-3/8
6-1/8
Floor
Plate
5-7/8
Cement
Case
Drill (3) 3/8” Dia. Clearance Holes
in Door for Arm Screws.Mounting
1-1/4
Right Hand Shown
Conversion from inches to metric: inch x 25.4
Where vertical adjustment is necessary,
two (2) 1/16” thick shims are provided to be
placed between arm and torque washer.
Template
PAGE 4
T
U
R
N
F
U
L
L
1
8
0
°
CLOSED
70°
15°
D
E
L
A
Y
E
D
A
C
T
I
O
N
I
f
e
q
u
i
p
p
e
d
3/4
3/4
2-3/8
4” 1”
3 Holes for
1/4”-20 x 2-1/8” Long
Truss Head Machine Screw
1-1/4
12-1/8
2-1/4
3/4
3/4
7/16
5/8
3/4
1/4 1/4
C
L
1-1/16
45/64
23/64
3/4
13/16
WITH FLOOR PLATE
Set Cement Case 1-1/4”
Below Surface of Finished Floor
3/16
3/4
11/16
Door Mortised
5/16 Deep
for Arm
1-1/8
1/16
1/8 R.
Bevel Edge
of Door
1/8 in 2
Jamb
Holes for
1/4-20x5/8" FHMS or
#14x1-1/2" FHWS
180 Top Pivot
2
4-1/4
3-55/64
2-45/64
3/8
1-35/64
25/64
1-1/8
5”
3/4
13/16 5/16
5/16
3/4 1/4
1/8 Min.
Clearance
3/16 R.
Bevel Heel Edge of Door
1/8 in 2
4-1/4
4-5/8
3-9/16
2-1/2
1-7/16 3/8
1-15/16
5”
4-9/16
3-15/32
2-1/2
1-1/8
1-17/32
7/16
Door Leaf Jamb Leaf
13/16 5/16
1-1/8
13/16
5/16
O
F
F
H
O
O
N
Rixson Specialty Door Controls www.rixson.com
ASSA ABLOY
RIXSON®
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2002, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
RIXSON®
866-474-9766 Technical Department
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
PAGE 3
PAGE 2
How To Determine
Hand of Door
LH RH
Face a door swinging open away from you. If it opens to the
right, it is right hand. If it opens to the left, it is left hand.
Arm Cap
RIGHT HAND installation
Arm Locking Set Screw
5/8-18UNF x 1” LG
Installation Instructions
1. Install Closer
Door Stop
1/8” Minimum From
Face of Door to Door Stop
Right Hand Door
Spindle Position
3/4” From Face
of Door to C of Spindle
L
13/16” From Face of
Jamb to C of Spindle
L
Door
Jamb
A. Measure 13/16” out from door jamb.
B. Allow 1/8” minimum clearance from door stop to door
face. Measure door thickness. Add 3/4”.
C. Where lines meet determines center line of closer.
2. Install Cement Case in Floor
A. For floor plate application: Cement case is set 1-1/4”
below floor level.
B. Set cement case with styrofoam and closer attached in
floor and block in position.
C.
D. CEMENT CASE SHOULD BE LEVEL. Place levels per
illustration.
E.
Case should be parallel with center line of door.
Grout in cement case with closer and styrofoam
attached. Cement should not get between closer and
case.
LEVEL IN BOTH
DIRECTIONS
4. Hang Door
Top Pivot Jamb Portion
Top Pivot Door Portion
Intermediate
(Side Jamb)
Pivot
Spindle Arm
Knuckle
IMPORTANT:
Use plumb line to make
sure that center line of
top pivot pin lines up
with center line of closer
spindle.
A. Install top pivot in door per template.
B. Install top pivot in frame per template.
C. Center line of pivot should line up with center line of
closer. Use plumb line as illustrated.
D. See template for intermediate pivot. Use one pivot for
doors up to 250 lbs. Use two pivots for doors between
250 and 400 lbs.
3. Install Top Pivot & Closer Arm
1
3
1
3
CAUTION: Closer is shipped with “valve” screws down.
DO NOT FORCE VALVE DOWN.
A. Remove styrofoam and metal plate from closer.
B. Attach top pivot and closer arm to door.
C. Attach top pivot to frame.
D. Place closer in hold-open position or turn closer
spindle to 90 position.
E. Set door on closer spindle. Do not attempt to close
the door.
F. Push item 1 “top pivot pin” into place. Attach “cap”
item 3. (Illustration) CAP MUST BE TIGHTENED
SECURELY.
G. Install intermediate pivots. (See intermediate pivot
template)
H. Open Closing Speed and Latch valves
(counterclockwise) one turn. Door will then close.
I.
J. Put arm cap on arm and secure TIGHTLY with cap
screw furnished.
K. Insert spacer blocks as shown and attach floor plate.
While working door back and forth TIGHTEN ARM
LOCKING SCREW SECURELY with wrench
furnished.
2
2
Spacer Block
(Typ. Two)
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department

Navigation menu