Rixson Checkmate Series S 99 826, 926, 626, 726 Installation Instructions 80 9399 0102 015
User Manual: Rixson Checkmate Series - s 99-826, 99-926, 99-626, 99-726 Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
RIXSON Checkmate® RIXSON Series 99-626/99-826 (with detector) ASSA ABLOY 99-726/99-926 (without detector) Installation Instructions ® CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility of misapplication or misadjustment. ASSA ABLOY Door Holder and Releasing Device WITH and WITHOUT Integral Smoke Detector ® Models Hinge (Pull) Side of Stop (Push) Side of Door Application Door Application 99-626 99-726 99-826 99-926 NOTES: - For wiring of 99-626/99-826 models, see "Checkmate®" "Wiring Instructions" No. 80-9399-0103-015 (07-14) 99-826 PULL SIDE illustrated LH – Left Hand Door RHR – Right Hand Reverse 99-726 PUSHL SIDE illustrated LH – Left Hand Door RHR – Right Hand Reverse 99-726 PUSH SIDE illustrated RH – Right Hand Door LHR – Left Hand Reverse Hinge Edge of Door Hinge Edge of Door 99-826 PULL SIDE illustrated RH – Right Hand Door LHR – Left Hand Reverse Components: Arm Bracket & Tube 99-826/99-926 Track Adjusting Screw 99-926 Hook-Up Box Adjusting Rod Smoke Detector 99-826 Hook-Up Box Preparation for Fasteners Pull (Hinge) Side Push (Stop) Side 99-626 Hook-Up Box 99-726 Hook-Up Box Door or Frame Drill-Sizes Aluminum or Metal No drill required Self-Drilling Screw Standard Wood 3/16” (4.30 mm) Pilot hole required 1/4” - 20 machine Metal Drill: #7 (0.201” dia.) Tap: 1/4” - 20 screw Hollow 9/32” (7 mm) through; Metal 3/8” (9.5 mm) door face opposite to closer Sleeve nuts and Aluminum 3/8” (9.5 mm) through bolts Optional or Wood 9/32” (7 mm); Through-bolts and All 3/8” (9.5 mm) dia. x grommet-nuts 3/8” (9.5 mm) deep on door opposite to closer Fasteners 99-626/99-726 Track Smoke Detector NOTE: For special applications a separate door and frame Unit must be mounted on interior of building in dry See NFPA70 for wiring requirements and NFPA72 for alarm preparation template is packed with these instructions. Use this instruction sheet for installation sequence and closer adjustments only. Use of an auxiliary door stop is always recommended. Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. environment, maximum humidity of 95%. system requirements. 1 80-9399-0102-015 (07-14) 99-826 / 99-926 Series RIXSON ASSA ABLOY Hinge (Pull) Side Application 1 Parts ® 2 Mark and Drill Holes Preparation for Fasteners Solenoid wire coiled inside end of track Power Track Dim. "A” Dim. "B” Fasteners 99-926 31-1/16 (788) 32-1/8 (816) Self-Drilling Screw 99-826 34-11/16 (881) 35-3/4 (908) 1/4”-20 machine screw CL Door or Frame Aluminum or Metal Wood (see Note) Metal Drill Sizes No drill required 3-16” (4.3mm) Drill #7 (.201” dia) Tap 1/4”-20 Note: Wood doors/frames MUST have pilot hole when using Self-Drilling Screws. 1/2 (13) B A 3-5/8 (92) 1-7/16 (37) 19 (483) 3/4 (19) 7-1/4 2-1/2 (64) (184) Right Hand Shown 7/8 (22) Conduit hole for concealed wiring only Installation Sequence See Page 4 for wiring instructions. B 4 3 After installed, bend out tabs to secure. C 1-1/4 (32) Hold Open Angle G (Between 85° and 110° only) A A Lock into hold-open D B D Use holes that align in arms F 2 E C Open door to 1 Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. desired angle 2 80-9399-0102-015 (07-14) 99-626 / 99-726 Series RIXSON ASSA ABLOY Stop (Push) Side Application 1 Parts ® Mark and Drill Holes 2 Preparation for Fasteners Power Track Dim. "A” Dim. "B” Fasteners PTO 30-9/16 (776) 31-11/16 (805) Self-Drilling Screw PTDO 34-3/16 (868) 35-5/16 (897) Solenoid wire coiled inside end of track 1/4”-20 machine screw Door or Frame Aluminum or Metal Wood (see Note) Metal Drill Sizes No drill required 3-16” (4.3mm) Drill #7 (.201” dia) Tap 1/4”-20 Note: Wood doors/frames MUST have pilot hole when using Self-Drilling Screws. B A CL 3-1/8 (79) 12 (305) 1/2 (13) 1-1/8 (29) hole for Conduit 1 (25) 19 (486) Bottom of Frame Stop 2-3/4 (70) 5-1/8 (130) Left Hand Shown 2-1/2 (64) Installation Sequence 3 Hold Open Angle 4 (Between 85° and 110° only) See Page 4 for wiring instructions. B F A Lock into hold-open B D Use holes that align in arms C A D 2 C Open door to desired angle 1 E Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 3 80-9399-0102-015 (07-14) RIXSON 99-726 / 99-926 Support Unit Wiring Diagram (120VAC Input) 99-726 / 99-926 Support Unit Wiring Diagram (24VAC/DC Input) Input Power Earth (+) (-) 24VAC/DC Circuit Board ASSA ABLOY (Do not use a 120VAC 99-726 / 99-926 unit when power is supplied from a 99-626 / 99-826 unit) Input 120VAC Circuit Board Power 4-Pin Jumper Earth 3 (+) 1 2 (-) 1 2 3 4 4-Pin Jumper 3 2 1 1 2 3 4 2-Pin Jumper Openings for surface wiring shown 2-Pin Jumper SOL Terminal Strip for Power Input Connection Openings for surface or concealed wiring Header for Solenoid Connection Fuse 125V / 1/2A ® SOL Terminal Strip for Power Input Connection Test Switch Header for Solenoid Connection Fuse 125V / 1/2A Test Switch ELECTRICAL DATA 120VAC 24VAC 24VDC Detector For 99-626/99-826 Models: 132V Max 26.4V Max 26.4V Max 26.4V Max Voltage 120V 102V Min 24V 20.4V Min 24V 20.4V Min 24V 20.4V Min Refer to Wiring Instructions No. 80-9399-0103-015 (02-09) for making wiring connections. Current .036 Amps .059 Amps .074 Amps 0.034 Amps NOTES: Maximum wire size is 14AWG. All wiring and connections use standard wiring practice conforming with local wiring codes. Cont.: increase the releasing force by turning the screw accessible thru the end cap of the track using the 9/64” hex wrench provided. Again, open door to the hold-open position. Depress “Test Switch” button on the hook-up board...door should close. If arm does not release, see previous step. IMPORTANT: Remove solenoid wire from end of track before installing track to frame. Do not pinch or crimp wire. Once track and hook-up box are installed, solenoid wire must be plugged into Header on circuit board shown above. After making all wiring connections: Turn power to unit “ON”. (On Master (99-626 / 99-826) unit only, red LED should illuminate once every 15 sec.). Track’s hold open force is preset at the factory. Open door to hold-open position. Manually pull door out of hold-open and release...door should close. If arm does not release from hold-open, Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. RIXSON ® ASSA ABLOY 3000 Highway 74 East • Monroe, NC 28112 Tel: (800)- 457- 5670 www.r ixson.com 4 80-9399-0102-015 (07-14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 4 Create Date : 2014:07:14 10:26:42-04:00 Modify Date : 2014:07:14 10:26:42-04:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : McNally;Tommy Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools