Rixson IS (F)M19(0) X 1.5 M19, FM19, M190, FM190 Intermediate Pivot 1 1/2' Offset FM190x1.5

User Manual: Rixson M19, FM19, M190, FM190 Intermediate Pivot 1-1/2' offset Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadRixson IS-(F)M19(0) X 1.5 M19, FM19, M190, FM190 Intermediate Pivot 1-1/2' Offset IS-FM190x1.5
Open PDF In BrowserView PDF
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2006, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

Bevel Heel Edge
of Door 1/8" in 2"
(3.2 in 50.8)

5/16
(8)

13/16
(20.6)

1/4
(6.4)

3/4
(19)
3/8
(9.5)
1-7/16
(36.5)

1-1/2
(38)
Door Leaf

Jamb Leaf

1-15/16
(49.2)

5/16
(8)
3/16
(4.8)

7/16
(11.1)

1/8 (3.2) Min. Clearance

1-1/8
(28.6)

1-17/32
(38.9)
2-1/2
(63.5)

2-1/2
(63.5)

3-15/32
(88.1)

3-9/16
(90.5)

3-7/8
(98.4)

4-5/8
(117.5)

4-9/16
(116)

5
(127)

5
(127)

5/16
(7.9)
13/16
(20.6)

5/16
(7.9)
1-1/8
(28.6)

5-3/4
(146)

1-1/8
(28.6)

13/16
(20.6)

Notes:
1. Do not scale drawing.
2. Dimensions are given in inches (mm).
3. Pivot drilled for 1/4-20 x 5/8" FHMS or #14 x 1-1/2" FHWS.
4. Right hand shown.
5. Template drawing for reference only.

M19, FM19, M190, and FM190
Intermediate Pivot
1-1/2" Offset

RIXSON

®

ASSA ABLOY
www.rixson.com

TEMPLATE NUMBER

IS- (F)M19 ( 0 ) x 1.5

DATE

07-09

Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2006, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

M19, FM19, M190 & FM190 Side Jamb Pivot
Handed
1-1/2” Offset
Installation Instructions
Door should already be hung with top pivot and bottom pivot (or floor closer)
1.

Mortise door & frame
per template on reverse side.

How To Determine
Hand of Door
LH

2.

Affix pivot to door & frame.

3.

Align pivot point from top
pivot to bottom arm. (See diagram)

4.

Loosen arm screw*.

5.

Remove hex cap.

6.

Turn stud screw clockwise.
Raise the door to the desired
height.

Face a door swinging open away from
you. If it opens to the right, it is right hand.
If it opens to the left, it is left hand.

8.

Turn stud screw
counterclockwise until
door rests on shims.

9.

Tighten arm screw
on spindle. Open and
close door several times
Re-tighten arm screw.

10.
7.

RH

Replace hex cap.

Using shims furnished with
bottom arm, fill gap between arm
and base.
* If bottom arm is for a UniChek 67/68 or 117 pivot,
make sure the arm is
sitting all the way down
on the base. Make NO
adjustments to the M19.

M19, FM19, M190, and FM190
Intermediate Pivot
1-1/2" Offset

RIXSON

®

ASSA ABLOY
www.rixson.com

TEMPLATE NUMBER

IS- (F)M19 ( 0 ) x 1.5

DATE

07-09



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : AdobePS5.dll Version 5.0.1
Modify Date                     : 2009:07:07 10:02:29-04:00
Create Date                     : 2009:07:07 10:02:29-04:00
Format                          : application/pdf
Title                           : IS-(F)M19(0) x 1.5.cdr
Document ID                     : uuid:9a55720f-c15b-4213-a21b-f74edc72057c
Instance ID                     : uuid:35d9b1d3-103c-4a59-974e-36888a2976b8
Page Count                      : 2
Creator                         : AdobePS5.dll Version 5.0.1
EXIF Metadata provided by EXIF.tools

Navigation menu