Robertshaw Controls Company d/b/a Invensys Home Control Systems Wireless Load Control Meter TD2001
User Manual
vLR1 Invensys RF Load Control Meter General Instructions Description TABLE 1. Specifications ve ns ys CURTAILMENT I N EFFECT In CURTAILMENT OVERRIDE Invensys RF Load Control Meter POWER The LCM is connected in line with the existing electrical wiring to the appliance, which enables it to be mounted at any location with easy access to the existing wiring. The enclosure is watertight, dust tight, and corrosion resistant, making it suitable for both indoor and outdoor locations. Mounting holes are provided at each corner to secure the LCM to a flat surface. FIGURE 1. COMM. ACTIVE WHEN FLASHING The Invensys RF Load Control Meter (LCM) is a remote switching device that receives load control OFF and ON commands from the GoodWatts system. Commands are received via an RF Communications network. ab Dis Mo F L sw conn itch ec de oad ma t p o C A l E C UT Ra y be er IO M on tin req sup N gs uir ply - Ris S L ed be 24 -2 rol Ra to fore k of intig 00 M 24 VAC ht et 0 V , 3 de-e serv lec en tr AC 0 A er clo , 2 mp ergiz icing ic Sh Des sure . M oc P, cr o k Fitti iptio hen Sin Resis the eq re th mo gle tive Lo ng A n P uip an ckin ss nte O-r g y. art N me on d w has Sing ing Nut CD um nt e d ith le NP 16AA ber be is Ph eith Do fore con as O -16- -B er of n o R-16-BK K se nec th t a e fo Des rvic t tt a N llow Fitti crip ing tio ch ing Lo ng A n two ck ss co O-r ing y. Par fittin nd tN u it ing Nut ED16 g in um 16 AA ber sta ab -BK -B llatio 6B ov ns: th is li n e. FC Item Electrical input: Description vL02606100: 120 VAC rms, 60 Hz., 2-wire vL02606200: 240 VAC rms, 60 Hz., 2-wire Contact rating: 30A @240VAC rms Wiring Terminals: #14 - #10 AWG, copper conductors only, solid or stranded Operating temperature: -40 to +65 deg. Celsius Storage temperature: -40 to +85 deg. Celsius Humidity tolerance: 0 to 100% RH (non-condensing) Enclosure: NEMA 4x rated Physical dimensions: 7.0” x 7.0” x 3.02” Weight: 2 lbs TABLE 2. Style Chart Model Style Description vL02606100 – Controls 120 VAC single-phase loads with current up to 30A resistive. – Supports 1 h.p. single phase inductive motor. vL02606200 – Controls 240 VAC single-phase loads with current up to 30A resistive. – Supports 2 h.p. single phase inductive motor. Th ID is Op dev: QI2 (1) eratioice co -EM (2) this n is mplieSL-1 su inclthis evic bje s w 00 ud dev e m ct to ith P ing ice ay inte mu not the fo rt 15 rfe st a cau llow of ren cc se in the ce ept ha g tw FC tha any rm o C t m in ful con Ru ay terf inte diti les. ca ere rfe on use n re s: un ce re nce, de ce an sire ive d d o d, pe ratio n. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. TD2001 COPYRIGHT© 2002 INVENYS HOME CONTROL SYSTEMS 8/6/02 INVENSYS RF LOAD CONTROL METER Installation Caution: This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations, Code of Federal Regulations Chapter 47 part 15 and must be installed in accordance with the instructions provided in this document. In accordance with FCC requirements, changes or modifications to this equipment that are not expressly approved by the party responsible for FCC compliance could void the user's authority to operate this equipment. Inspection Inspect the carton for damage. If damaged, notify carrier immediately. Inspect LCM for damage. Return damaged products. Requirements – Installer must be a qualified, experienced technician. – Job wiring diagrams – Tools • Drill bits for panel mounting holes • Static protection wrist strap – Mounting screws (4) General Precautions Warning: Electrical shock hazard! High voltage is present in the Load Control Meter. Turn OFF electrical power to the LCM and the electrical appliance prior to installation or service. Failure to turn off power may result in serious personal injury. – Follow Static Precautions when installing this equipment. – Use suitable copper conductors. – Make all connections according to electrical wiring diagram, national and local electrical codes. Static Precautions Static charges damage electronic components. The microprocessor and associated circuitry are sensitive to static discharge. Use the following precautions when installing, servicing, or operating the system. – Work in a static free area – Discharge static electricity by touching a known, securely grounded object. Location The LCM is connected in line with the existing electrical wiring to the appliance, which enables it to be mounted at any location with easy access to the existing wiring. The enclosure is watertight, dust tight, and corrosion resistant, making it suitable for both indoor and outdoor locations. – Avoid mounting locations where excessive moisture, corrosive fumes, vibration, or explosive vapors are present. – Avoid electrical noise interference. Do not install near large contactors, electrical machinery, or welding equipment. – Locate where ambient temperatures do not exceed 150 deg. F (65 deg. C) or fall below -40 deg. F (-40 deg. C). PRELIMINARY DOCUMENT TD2001 MOUNTING Mounting Mounting holes are provided at each corner to secure the LCM to a flat surface. Figure 4 shows mounting dimensions. Refer to FIGURE 9. Mounting Template, on page 8 for an installation template at actual size. FIGURE 2. Enclosure dimensions 7.00 [177.83] 5.43 [138.03] 5.43 [138.03] END VIEW 5.50 [139.58] 3.02 [76.62] MOUNTING HOLES 1.00 [25.40] 1.42 [36.09] 7.00 [177.83] 1.97 [50.00] MOUNTING HOLES 6.90 [175.36] REAR VIEW 6.18 [157.03] 3.94 [100.00] 5.51 [140.00] 0.39 [10.00] 1.99 [50.50] 5.00 [127.00] 3.94 [100.00] 5.51 [140.00] 6.18 [157.01] NOTE: DIMENSIONS ARE IN INCHES (MILLIMETERS) 1. Select a flat mounting location. 2. Mark and prepare the surface mounting holes, using dimensions above or use the template in FIGURE 9. Mounting Template, on page 8. 3. Remove the cover from the LCM enclosure by removing the four cover attaching screws in the corners of the cover. 4. Insert mounting screws down through the same holes that the cover screws came out of and securely fasten the LCM enclosure to the flat surface. 8/6/02 PRELIMINARY DOCUMENT INVENSYS RF LOAD CONTROL METER FIGURE 3. Mounting screw location 5. Refer to Wiring, on page 4 and wire the LCM. 6. After wiring is complete, replace the cover and tighten it securely with the four cover screws. 7. Reapply power to the LCM and the electrical appliance. Wiring Caution: It is important to select cable that complies with the NEC code for the electrical appliance being wired. The EMSL-100 can control 120 VAC single-phase loads with current ratings up to 30A resistive. The EMSL-200 can control 240 VAC single-phase loads with current ratings up to 30A resistive. The LCM is connected in-line with the existing electrical wiring to the appliance. Multiple-size knockouts are provided around the exterior perimeter of the housing to accommodate a conduit connector or a cable clamp. Refer to the wiring chart in Table 3 for terminal listings for both LCM models. Refer also to the example wiring diagrams in Figure 5 through Figure 8. Warning: You must turn off AC power to the electrical appliance that you are wiring. Failure to turn off power could result in physical injury or death. 1. Shut off AC power to the electrical appliance being wired. Caution: Use only NEMA 4x rated fittings in order to maintain the NEMA 4x rating. 2. Connect the wires for the input (from the AC source) and output (to the electrical appliance) as shown in Table 3 and in Figure 4. Refer to Figure 4 to see typical wiring for a 120 VAC and a 240 VAC system. PRELIMINARY DOCUMENT TD2001 WIRING Note: In four-wire 240 VAC configuration, the neutral wire is not connected to the LCM. TABLE 3. Wiring Chart LCM Style Bottom Terminal Center Terminal Top Terminal vL02606100 Ground (green) Neutral (white) Hot (black) vL02606200 Ground (green or bare) L2 (red) L1 (black) FIGURE 4. L1 L1 L 2/N EARTH GROUND LINE 1 BLACK NEUTRAL WHITE L2/ N EARTH GREEN 240 VAC 120 VAC HOT Installation wiring connections for a 120 and 240 VAC application BLACK L1 L1 L2 /N EARTH GROUND 120 VAC SYSTEM WIRING LINE 2 RED L2 /N EARTH GREEN OR BARE 240 VAC SYSTEM WIRING 3. When wiring is complete reinstall cover (see Mounting on page 3) and apply power to the LCM and the electrical appliance. 8/6/02 PRELIMINARY DOCUMENT INVENSYS RF LOAD CONTROL METER Sample Wiring Schematics The following schematics provide examples of wiring for hot water heaters and pool pumps for both 120 VAC and 240 VAC applications. FIGURE 5. Example wiring for 120 VAC water heater application 120 VOLT AC WATER HEATER 30 AMPS MAX LOAD CONTROL METER MEASUREMENT AND CONTROL ELECTRONICS 120 VOLTS LINE 1 CIRCUIT BREAKER NEUTRAL GROUND EXISTING WATER HEATER THERMOSTAT FIGURE 6. Example wiring for 240 VAC water heater application LOAD CONTROL METER 240 VOLT AC WATER HEATER 30 AMPS MAX MEASUREMENT AND CONTROL ELECTRONICS 240 VOLTS LINE 1 LINE 2 CIRCUIT BREAKER GROUND EXISTING WATER HEATER THERMOSTAT PRELIMINARY DOCUMENT TD2001 WIRING FIGURE 7. Example wiring for 120 VAC pool pump application LOAD CONTROL METER MEASUREMENT AND CONTROL ELECTRONICS EXISTING CIRCUIT DISCONNECT 120 VOLTS LINE 1 CIRCUIT BREAKER NEUTRAL 120 VOLT AC POOL PUMP 1 HP MAX GROUND FIGURE 8. Example wiring for 240 VAC pool pump application LOAD CONTROL METER MEASUREMENT AND CONTROL ELECTRONICS EXISTING CIRCUIT DISCONNECT 240 VOLTS LINE 1 LINE 2 CIRCUIT BREAKER GROUND 8/6/02 PRELIMINARY DOCUMENT 240 VOLT AC POOL PUMP 2 HP MAX INVENSYS RF LOAD CONTROL METER Mounting Template Note: To ensure accuracy, this template must be printed at 100% actual size. FIGURE 9. Mounting Template 7.00 (177.83) ALL DIMENSIONS SHOWN = INCHES (MILLIMETERS) PRELIMINARY DOCUMENT 6.18 (157.01) 7.00 (177.83) 6.18 (157.01) TD2001 MOUNTING TEMPLATE LCM Operations The only visible controls or indicators on the Invensys RF Load Control Meter are the four surface mount LED’s. These indicators are listed in described in TABLE 4. LED indicator descriptions, below. TABLE 4. LED indicator descriptions LED Label Power Color Green Description The green power light illuminates continuously when the following two conditions are met: – Power is applied to the LCM – The LCM is active (processor up) Comm. Active when Flashing Green The green communications active light is firmware controlled and blinks to indicate activity in the RF communications subsystem. Curtailment in Effect Amber The amber curtailment light illuminates to indicate that a curtailment is in effect. The LED is OFF when no curtailment is in effect. Curtailments may be initiated by the appropriate power provider in accordance with a particular GoodWatts program. Curtailment Override Red The red override light illuminates when the Criminate Override switch has been set to the ON position. The light is OFF when Curtailment Override switch is set to the OFF position. LED LOCATIONS COMM. ACTIVE WHEN FLASHING CURTAILMENT IN EFFECT POWER GREEN GREEN AMBER 8/6/02 PRELIMINARY DOCUMENT OVERRIDE CURTAILEMENT RED © Invensys 2002 All specifications are nominal and may change as design improvements are introduced. Invensys shall not be liable for damages resulting from misapplication or misuse of its products. Marks bearing ® and/or ™ are registered trademarks and trademarks of Invensys. Terms and product names in this document may be trademarks of others. TD2001 INVENSYS RF LOAD CONTROL METER PRINTED IN U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2002:08:08 21:00:07Z Modify Date : 2002:09:02 14:12:50-07:00 Creator : AdobePS5.dll Version 5.2.1 Page Count : 10 Creation Date : 2002:08:08 21:00:07Z Mod Date : 2002:09:02 14:12:50-07:00 Producer : Acrobat Distiller 5.0.5 (Windows) Metadata Date : 2002:09:02 14:12:50-07:00 Title : TD2001.fmEXIF Metadata provided by EXIF.tools