Robertshaw Controls d b a Invensys Home Control Systems EMSL-200 Wireless Load Control Meter User Manual TD2001

Robertshaw Controls Company d/b/a Invensys Home Control Systems Wireless Load Control Meter TD2001

User Manual

Download: Robertshaw Controls d b a Invensys Home Control Systems EMSL-200 Wireless Load Control Meter User Manual TD2001
Mirror Download [FCC.gov]Robertshaw Controls d b a Invensys Home Control Systems EMSL-200 Wireless Load Control Meter User Manual TD2001
Document ID267609
Application IDB8gCZ6Rf3rWBy4tB5gGj9Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.31kB (266315 bits)
Date Submitted2002-09-03 00:00:00
Date Available2002-09-03 00:00:00
Creation Date2002-08-08 21:00:07
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2002-09-02 14:12:50
Document TitleTD2001.fm
Document CreatorAdobePS5.dll Version 5.2.1

vLR1
Invensys RF Load Control Meter
General Instructions
Description
TABLE 1. Specifications
ve
ns
ys
CURTAILMENT
I N EFFECT
In
CURTAILMENT
OVERRIDE
Invensys RF Load Control Meter
POWER
The LCM is connected in line with the existing
electrical wiring to the appliance, which enables it to
be mounted at any location with easy access to the
existing wiring. The enclosure is watertight, dust
tight, and corrosion resistant, making it suitable for
both indoor and outdoor locations. Mounting holes
are provided at each corner to secure the LCM to a
flat surface.
FIGURE 1.
COMM. ACTIVE
WHEN FLASHING
The Invensys RF Load Control Meter (LCM) is a
remote switching device that receives load control
OFF and ON commands from the GoodWatts
system. Commands are received via an RF
Communications network.
ab
Dis
Mo F L
sw conn
itch ec
de oad
ma t p o C A
l E C
UT
Ra y be er
IO
M on
tin
req sup N
gs
uir ply - Ris S L
ed be
24
-2 rol
Ra
to fore k of
intig
00 M
24 VAC
ht
et
0 V , 3 de-e serv lec
en
tr
AC 0 A
er
clo
, 2 mp ergiz icing ic Sh
Des sure
. M oc
P,
cr
o k
Fitti iptio hen
Sin Resis the
eq re th mo
gle tive
Lo ng A n P
uip an
ckin ss
nte
O-r g y. art N
me on
d w has Sing
ing Nut CD um
nt e d
ith
le
NP 16AA ber
be is
Ph
eith
Do
fore con
as
O -16- -B
er
of
n o R-16-BK K
se nec
th
t a
e fo
Des
rvic t
tt a N
llow
Fitti crip
ing
tio
ch
ing
Lo ng A n
two
ck ss
co
O-r ing y. Par
fittin
nd
tN
u it ing Nut ED16
g in
um
16 AA ber
sta
ab
-BK -B
llatio
6B
ov
ns:
th
is
li n
e.
FC
Item
Electrical
input:
Description
vL02606100: 120 VAC rms, 60 Hz., 2-wire
vL02606200: 240 VAC rms, 60 Hz., 2-wire
Contact
rating:
30A @240VAC rms
Wiring
Terminals:
#14 - #10 AWG, copper conductors only, solid
or stranded
Operating
temperature:
-40 to +65 deg. Celsius
Storage
temperature:
-40 to +85 deg. Celsius
Humidity
tolerance:
0 to 100% RH (non-condensing)
Enclosure:
NEMA 4x rated
Physical
dimensions:
7.0” x 7.0” x 3.02”
Weight:
2 lbs
TABLE 2. Style Chart
Model Style
Description
vL02606100
– Controls 120 VAC single-phase loads with
current up to 30A resistive.
– Supports 1 h.p. single phase inductive motor.
vL02606200
– Controls 240 VAC single-phase loads with
current up to 30A resistive.
– Supports 2 h.p. single phase inductive motor.
Th ID
is
Op dev: QI2
(1) eratioice co -EM
(2) this n is mplieSL-1
su
inclthis evic bje s w 00
ud dev e m ct to ith P
ing ice ay
inte mu not the fo rt 15
rfe st a cau llow of
ren cc se in the
ce ept ha g tw FC
tha any rm o C
t m in ful con Ru
ay terf inte diti les.
ca ere rfe on
use n re s:
un ce re nce,
de ce an
sire ive d
d o d,
pe
ratio
n.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and
receiver.
– Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
– Consult the dealer or an experienced radio/TV
technician for help.
TD2001
COPYRIGHT© 2002 INVENYS HOME CONTROL SYSTEMS
8/6/02
INVENSYS RF LOAD CONTROL METER
Installation
Caution: This equipment is authorized for use under the United States Federal
Communication Commission Rules and Regulations, Code of Federal Regulations
Chapter 47 part 15 and must be installed in accordance with the instructions provided in
this document. In accordance with FCC requirements, changes or modifications to this
equipment that are not expressly approved by the party responsible for FCC compliance
could void the user's authority to operate this equipment.
Inspection
Inspect the carton for damage. If damaged, notify carrier immediately. Inspect
LCM for damage. Return damaged products.
Requirements
– Installer must be a qualified, experienced technician.
– Job wiring diagrams
– Tools
• Drill bits for panel mounting holes
• Static protection wrist strap
– Mounting screws (4)
General Precautions
Warning: Electrical shock hazard! High voltage is present in the Load Control Meter.
Turn OFF electrical power to the LCM and the electrical appliance prior to installation
or service. Failure to turn off power may result in serious personal injury.
– Follow Static Precautions when installing this equipment.
– Use suitable copper conductors.
– Make all connections according to electrical wiring diagram, national and local
electrical codes.
Static Precautions
Static charges damage electronic components. The microprocessor and
associated circuitry are sensitive to static discharge. Use the following
precautions when installing, servicing, or operating the system.
– Work in a static free area
– Discharge static electricity by touching a known, securely grounded object.
Location
The LCM is connected in line with the existing electrical wiring to the appliance,
which enables it to be mounted at any location with easy access to the existing
wiring. The enclosure is watertight, dust tight, and corrosion resistant, making it
suitable for both indoor and outdoor locations.
– Avoid mounting locations where excessive moisture, corrosive fumes, vibration, or
explosive vapors are present.
– Avoid electrical noise interference. Do not install near large contactors, electrical
machinery, or welding equipment.
– Locate where ambient temperatures do not exceed 150 deg. F (65 deg. C) or fall
below -40 deg. F (-40 deg. C).
PRELIMINARY DOCUMENT
TD2001
MOUNTING
Mounting
Mounting holes are provided at each corner to secure the LCM to a flat surface. Figure 4
shows mounting dimensions. Refer to FIGURE 9. Mounting Template, on page 8 for an
installation template at actual size.
FIGURE 2.
Enclosure dimensions
7.00 [177.83]
5.43 [138.03]
5.43 [138.03]
END VIEW
5.50 [139.58]
3.02 [76.62]
MOUNTING HOLES
1.00 [25.40]
1.42 [36.09]
7.00 [177.83]
1.97 [50.00]
MOUNTING HOLES
6.90 [175.36]
REAR VIEW
6.18 [157.03]
3.94 [100.00]
5.51 [140.00]
0.39 [10.00]
1.99 [50.50]
5.00 [127.00]
3.94 [100.00]
5.51 [140.00]
6.18 [157.01]
NOTE: DIMENSIONS ARE IN INCHES (MILLIMETERS)
1. Select a flat mounting location.
2. Mark and prepare the surface mounting holes, using dimensions above or use the
template in FIGURE 9. Mounting Template, on page 8.
3. Remove the cover from the LCM enclosure by removing the four cover attaching
screws in the corners of the cover.
4. Insert mounting screws down through the same holes that the cover screws came
out of and securely fasten the LCM enclosure to the flat surface.
8/6/02
PRELIMINARY DOCUMENT
INVENSYS RF LOAD CONTROL METER
FIGURE 3.
Mounting screw location
5. Refer to Wiring, on page 4 and wire the LCM.
6. After wiring is complete, replace the cover and tighten it securely with the four cover
screws.
7. Reapply power to the LCM and the electrical appliance.
Wiring
Caution: It is important to select cable that complies with the NEC code for the
electrical appliance being wired.
The EMSL-100 can control 120 VAC single-phase loads with current ratings up to 30A
resistive. The EMSL-200 can control 240 VAC single-phase loads with current ratings up
to 30A resistive. The LCM is connected in-line with the existing electrical wiring to the
appliance. Multiple-size knockouts are provided around the exterior perimeter of the
housing to accommodate a conduit connector or a cable clamp. Refer to the wiring
chart in Table 3 for terminal listings for both LCM models. Refer also to the example
wiring diagrams in Figure 5 through Figure 8.
Warning: You must turn off AC power to the electrical appliance that you are wiring.
Failure to turn off power could result in physical injury or death.
1. Shut off AC power to the electrical appliance being wired.
Caution: Use only NEMA 4x rated fittings in order to maintain the NEMA 4x rating.
2. Connect the wires for the input (from the AC source) and output (to the electrical
appliance) as shown in Table 3 and in Figure 4. Refer to Figure 4 to see typical wiring
for a 120 VAC and a 240 VAC system.
PRELIMINARY DOCUMENT
TD2001
WIRING
Note: In four-wire 240 VAC configuration, the neutral wire is not connected to the LCM.
TABLE 3. Wiring Chart
LCM Style
Bottom Terminal
Center Terminal
Top Terminal
vL02606100
Ground (green)
Neutral (white)
Hot (black)
vL02606200
Ground (green or bare)
L2 (red)
L1 (black)
FIGURE 4.
L1
L1
L 2/N
EARTH
GROUND
LINE 1
BLACK
NEUTRAL
WHITE
L2/ N
EARTH
GREEN
240 VAC
120 VAC
HOT
Installation wiring connections for a 120 and 240 VAC application
BLACK
L1
L1
L2 /N
EARTH
GROUND
120 VAC SYSTEM WIRING
LINE 2
RED
L2 /N
EARTH
GREEN OR BARE
240 VAC SYSTEM WIRING
3. When wiring is complete reinstall cover (see Mounting on page 3) and apply power
to the LCM and the electrical appliance.
8/6/02
PRELIMINARY DOCUMENT
INVENSYS RF LOAD CONTROL METER
Sample Wiring Schematics
The following schematics provide examples of wiring for hot water heaters and pool
pumps for both 120 VAC and 240 VAC applications.
FIGURE 5.
Example wiring for 120 VAC water heater application
120 VOLT AC WATER HEATER
30 AMPS MAX
LOAD CONTROL METER
MEASUREMENT
AND
CONTROL
ELECTRONICS
120
VOLTS
LINE 1
CIRCUIT
BREAKER
NEUTRAL
GROUND
EXISTING
WATER HEATER
THERMOSTAT
FIGURE 6.
Example wiring for 240 VAC water heater application
LOAD CONTROL METER
240 VOLT AC WATER HEATER
30 AMPS MAX
MEASUREMENT
AND
CONTROL
ELECTRONICS
240
VOLTS
LINE 1
LINE 2
CIRCUIT
BREAKER
GROUND
EXISTING
WATER HEATER
THERMOSTAT
PRELIMINARY DOCUMENT
TD2001
WIRING
FIGURE 7.
Example wiring for 120 VAC pool pump application
LOAD CONTROL METER
MEASUREMENT
AND
CONTROL
ELECTRONICS
EXISTING
CIRCUIT
DISCONNECT
120
VOLTS
LINE 1
CIRCUIT
BREAKER
NEUTRAL
120 VOLT AC POOL PUMP
1 HP MAX
GROUND
FIGURE 8.
Example wiring for 240 VAC pool pump application
LOAD CONTROL METER
MEASUREMENT
AND
CONTROL
ELECTRONICS
EXISTING
CIRCUIT
DISCONNECT
240
VOLTS
LINE 1
LINE 2
CIRCUIT
BREAKER
GROUND
8/6/02
PRELIMINARY DOCUMENT
240 VOLT AC POOL PUMP
2 HP MAX
INVENSYS RF LOAD CONTROL METER
Mounting Template
Note:
To ensure accuracy, this template must be printed at 100% actual size.
FIGURE 9.
Mounting Template
7.00 (177.83)
ALL DIMENSIONS SHOWN = INCHES (MILLIMETERS)
PRELIMINARY DOCUMENT
6.18 (157.01)
7.00 (177.83)
6.18 (157.01)
TD2001
MOUNTING TEMPLATE
LCM Operations
The only visible controls or indicators on the Invensys RF Load Control Meter
are the four surface mount LED’s. These indicators are listed in described in
TABLE 4. LED indicator descriptions, below.
TABLE 4. LED indicator descriptions
LED Label
Power
Color
Green
Description
The green power light illuminates continuously when the following
two conditions are met:
– Power is applied to the LCM
– The LCM is active (processor up)
Comm. Active
when Flashing
Green
The green communications active light is firmware controlled and
blinks to indicate activity in the RF communications subsystem.
Curtailment in
Effect
Amber
The amber curtailment light illuminates to indicate that a
curtailment is in effect. The LED is OFF when no curtailment is in
effect. Curtailments may be initiated by the appropriate power
provider in accordance with a particular GoodWatts program.
Curtailment
Override
Red
The red override light illuminates when the Criminate Override
switch has been set to the ON position. The light is OFF when
Curtailment Override switch is set to the OFF position.
LED LOCATIONS
COMM. ACTIVE WHEN FLASHING
CURTAILMENT IN EFFECT
POWER
GREEN GREEN AMBER
8/6/02
PRELIMINARY DOCUMENT
OVERRIDE CURTAILEMENT
RED
© Invensys 2002
All specifications are nominal and may change as design improvements are introduced. Invensys shall not be liable for damages resulting from misapplication or misuse of its products.
Marks bearing ® and/or ™ are registered trademarks and trademarks of Invensys.
Terms and product names in this document may be trademarks of others.
TD2001
INVENSYS RF LOAD CONTROL METER
PRINTED IN U.S.A.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2002:08:08 21:00:07Z
Modify Date                     : 2002:09:02 14:12:50-07:00
Creator                         : AdobePS5.dll Version 5.2.1
Page Count                      : 10
Creation Date                   : 2002:08:08 21:00:07Z
Mod Date                        : 2002:09:02 14:12:50-07:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Metadata Date                   : 2002:09:02 14:12:50-07:00
Title                           : TD2001.fm
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QI2-EMSL-200

Navigation menu