Robinair Refrigerant Recovery Unit 25200B Users Manual
2015-02-06
: Robinair Robinair-Refrigerant-Recovery-Unit-25200B-Users-Manual-524668 robinair-refrigerant-recovery-unit-25200b-users-manual-524668 robinair pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
O p e r a t i Operating Manual Manual de funcionamiento Manuel d’utilisation n g M a n u a l Not for use in automotive R-134a applications. Model 25200B Refrigerant Recovery Unit Model 25200B Refrigerant Recovery Unit Design Pressure: 336 psig — 435 psig SAFETY DEFINITIONS: Follow all WARNING, CAUTION, IMPORTANT, and NOTE messages in this manual. These messages are defined as follows: WARNING means you may risk serious personal injury or death; CAUTION means you may risk personal injury, property damage, or unit damage; IMPORTANT means you may risk unit damage; and NOTEs and operating Tips provide clarity and helpful information. These safety messages cover situations ROBINAIR is aware of. ROBINAIR cannot know, evaluate, and advise you as to all possible hazards. You must verify that conditions and procedures do not jeopardize your personal safety. DISCLAIMER: Information, illustrations, and specifications contained in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without obligation to notify any person or organization of such revisions or changes. Further, ROBINAIR shall not be liable for errors contained herein or for incidental or consequential damages (including lost profits) in connection with the furnishing, performance, or use of this material. If necessary, obtain additional health and safety information from the appropriate government agencies and the vehicle, refrigerant, and lubricant manufacturers. WARNINGS ALLOW ONLY QUALIFIED PERSONNEL TO OPERATE THE UNIT. Before operating the unit, read and follow the instructions and warnings in this manual. The operator must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. If the operator cannot read this manual, operating instructions and safety precautions must be read and discussed in the operator’s native language. PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Do not overfill the internal storage vessel, because overfilling may cause explosion and personal injury or death. Do not recover refrigerants into nonrefillable containers; use only federally authorized refillable containers (DOT spec. 4BW or 4BA). HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. Contact with refrigerant may cause personal injury. Wear protective equipment, including safety goggles. Disconnect hoses using extreme caution. DO NOT BREATHE REFRIGERANT AND LUBRICANT VAPOR OR MIST. Exposure may cause personal injury, especially to the eyes, nose, throat, and lungs. Use the unit in locations with mechanical ventilation that provides at least four air changes per hour, or position the unit 18 inches above the floor. If accidental system discharge occurs, ventilate the work area before resuming service. DO NOT USE AN EXTENSION CORD. An extension cord may overheat and cause fire. If you must use an extension cord, use the shortest possible cord with a minimum size of 14 AWG. TO REDUCE THE RISK OF FIRE, do not use the unit in the vicinity of spilled or open containers of gasoline or other flammable substances. DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR LEAK TEST THE UNIT OR HVAC/R SYSTEM. Some mixtures of air and refrigerant are combustible at elevated pressures. These mixtures are potentially dangerous and may result in fire or explosion causing personal injury or property damage. USE THIS UNIT WITH only the following REFRIGERANTs: R-12, R-22, R-134a, R-401a, R-401B, R-402A, R-402B, R-404A, R-407A, R-407B, R-407C, R-408A, R-409A, R-410A, R-500, R-502, R-507. The unit is designed to only recover refrigerant. Do not attempt to adapt the unit for refrigerant that is not in this list. Do not mix refrigerant types through a system or in the same container; mixing of refrigerants will cause severe damage to the unit and the air conditioning system. HIGH VOLTAGE ELECTRICITY INSIDE THE UNIT HAS A RISK OF ELECTRICAL SHOCK. Exposure may cause personal injury. Disconnect the power before servicing the unit. additional health and safety information may be obtained from the refrigerant and lubricant manufacturers. This equipment has been certified by ARI to meet the EPA minimum requirements for recovery equipment intended for use with all HCFC applicances and other high pressure applicances. Operating Note: At temperatures exceeding 120° F / 49° C, wait 10 minutes between recovery jobs. Introduction Table of Contents Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Operating Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setup Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . 4 Recovery Procedure . . . . . . . . . . . . . . . . . . . . . . . . 4 Tank-to-Tank Transfer . . . . . . . . . . . . . . . . . . . . . . 5 High Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Self-Clearing Procedure . . . . . . . . . . . . . . . . . . . . . . 6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . 7 Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . 8 Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Warranty Statement . . . . . . . . . . . . . . . . . . . . . . . . . 12 Safety Precautions . . . . . . . . . . . . . . . . . inside front cover Glossary of Terms A/C-R Air conditioning or refrigeration. A/C-R System The air conditioning or refrigeration system being serviced. Unit The refrigerant recovery unit. Tank The refillable refrigerant tank. 552701 Rev. A April 7, 2009 1 Setup Instructions Operating Guidelines • The voltage at the unit must be ±10% of the unit’s rated voltage. • Extension cords must be a minimum of 14 AWG and kept as short as possible. • To minimize mixing of refrigerants, the self-clearing procedure must be performed after each recovery operation. • The low-side gauge on the unit allows you to monitor system pressure and stop recovery when a deep enough vacuum has been reached. The high-side gauge allows you to monitor the refillable tank pressure. • When changing from liquid to vapor, the unit may switch back and forth several times before staying on vapor. You may notice the liquid light switching and hear the solenoids opening and closing. This is normal and does not affect the unit or its operation. SET-UP INSTRUCTIONS The unit comes with four 60-inch Enviro-Guard hoses with ball valves. Either blue hose may be used where blue hose connections are called for, and either red hose may be used for red hose connections. CAUTION: To prevent personal injury, all valves on hoses must be in the closed position before making connections. 1. Connect the hoses as follows: Hose Connect Standard End To: Connect Ball Valve End To: Red Hose TANK VAPOR fitting on unit VAPOR port on tank Blue Hose Blue Hose Red Hose TANK LIQUID fitting on unit SYSTEM VAPOR fitting on unit SYSTEM LIQUID fitting on unit LIQUID port on tank SYSTEM VAPOR port SYSTEM LIQUID port 2. Plug the unit into a correct voltage electrical outlet. The fan starts running immediately and the unit is ready for operation. 2 Setup Instructions Liquid Indicator Tank Pressure System Pressure Circuit Breaker High Pressure Indicator Recover / Power / Clear Switch Front View of Unit Liquid Vapor Valve Valve TyPICAL A/C-R SySTEM Vapor TANk VAPOR SySTEM VAPOR TANk LIQUID Liquid SySTEM LIQUID Hose Connections 552701 Rev. A April 7, 2009 3 Operating Instructions Recovery Procedure WARNING To prevent personal injury, Read and follow all warnings at the beginning of this manual before operating the unit. Wear safety goggles when working with refrigerants. Use only authorized refillable refrigerant tanks. Disconnect hoses using extreme caution. All hoses may contain refrigerant under pressure. 1. Connect hoses as described in the Setup Instructions. 2. Open the LIQUID and VAPOR valves on the recovery tank. Open the ball valves on all four hoses. NOTE: To prevent overfilling, monitor the tank capacity/weight during recovery. During liquid recovery, refrigerant transfers rapidly. Monitor tank weight using the appropriate weight scale. 3. Look at the system pressure gauge on the unit to confirm there is refrigerant pressure in the system. If there is no pressure, there is no refrigerant to be recovered. NOTE: By taking the ambient temperature and using a pressure/temperature chart, you can use this pressure to determine the type of refrigerant in the system. 4. Turn the switch to RECOVER. The light on the switch illuminates and you will hear the compressor start. A float chamber monitors the refrigerant being recovered and automatically adjusts the unit to handle either liquid or vapor refrigerant. This provides for the most efficient recovery. The amber light on the control panel indicates when liquid is entering the unit. 5. The blue gauge labeled SYSTEM PRESSURE shows the current system pressure throughout the recovery process. When the system pressure reaches an adequate vacuum level, turn the RECOVERY switch OFF. The recovery process is complete, but the unit must be cleared before disconnecting all hoses. (Refer to the Self-Clearing Procedure.) Tank Capacity Chart Refrigerants 30 lb. Tank R-12 22 lbs. 4 R-22 R-134a R-407C R-410A 22 lbs. 22 lbs. 21 lbs. 19 lbs. 50 lb. Tank 40 lbs. 40 lbs. 41 lbs. 39 lbs. 36 lbs. Operating Instructions WARNING The refrigerant level in the tank must not exceed 80% of the tank volume. Failure to monitor the level could result in excessive hydrostatic pressures, causing physical injury or death. tank-to-tank transfer When recovering refrigerant from one refillable tank into another, the color of the hoses used for SYSTEM LIQUID and SYSTEM VAPOR may not match the color of the liquid and vapor valves on the tank you are pulling the refrigerant from. Confirm the hose for SYSTEM LIQUID is connected to the liquid valve of the tank, and the hose for SYSTEM VAPOR is connected to the vapor valve of the tank. 1. Connect the hoses in the following manner. Standard End connects to: Ball Valve End connects to: TANK LIQUID fitting on unit LIQUID port on tank refrigerant is being transferred into TANK VAPOR fitting on unit VAPOR port on tank refrigerant is being transferred into SYSTEM VAPOR fitting on unit VAPOR port on tank refrigerant is being transferred from SYSTEM LIQUID fitting on unit LIQUID port on tank refrigerant is being transferred from 2. Follow Steps 1 through 5 in the Recovery Procedure on the previous page. NOTE: Remember to monitor tank weight. high pressure If, during the recovery or self-clearing process, the HIGH PRESSURE light comes on, verify all appropriate valves are open. If the valves are open and the light is still on, there is an excessive amount of air or the tank is full. Follow these steps: 1. Press the COMPRESSOR switch to OFF. 2. Close both valves on the refillable tank, and close both valves on the red and blue hoses connected to the tank. 3. Disconnect the red hose and the blue hose from the refillable tank. 4. Replace this tank with an empty refillable tank. 5. Reconnect the hoses as described in the Setup Instructions. Then follow the steps in either the Recovery Procedure or the Self-Clearing Procedure. If, after completing the above steps, either light is still on, call the Technical Support Line at (800) 822-5561. 552701 Rev. A April 7, 2009 5 Operating Instructions Self-Clearing Procedure CAUTION! Do not mix refrigerant types. Always perform the selfclearing procedure after each recovery. Beginning each job with a “clean” unit will help eliminate mixing of different refrigerant types. 1. Close the ball valves on the red and blue hoses connected to the A/C-R system. Disconnect these hoses from the system’s access ports. 2. Close the blue LIQUID valve on the tank and the ball valve on the blue TANK LIQUID hose. Disconnect the TANK LIQUID hose from the tank. 3. Verify the red TANK VAPOR hose is still connected to the red VAPOR fitting on the tank. Both the tank’s red VAPOR valve and the ball valve on the red TANK VAPOR hose should be open. 4. Press the switch to SELF-CLEAR. You will hear the compressor start and the switch will illuminate. 5. Let the compressor run until the system pressure gauge reaches the appropriate vacuum level. The system pressure gauge will return to VACUUM. Press the COMPRESSOR switch to OFF. Unplug the unit from the electrical source. 6. Close the red VAPOR valve on the tank and the ball valve on the red TANK VAPOR hose. Disconnect the TANK VAPOR hose from the tank. WARNING To prevent personal injury, disconnect hoses using extreme caution. All hoses may contain refrigerant under pressure. 7. While the hoses are still connected to the unit, slowly open the ball valve on each hose to relieve any pressure in the hose. Close the ball valves, then disconnect the hoses from the unit. 6 Maintenance This unit has been designed for minimal maintenance. The compressor should be evaluated for wear after 2,500 hours of use. Call Robinair’s Technical Support Line, (800) 822-5561, for the location of an authorized Robinair service center near you. Replacement Parts System Pressure Gauge Tank Pressure Gauge Switch—Compressor High Pressure Cut-Out Ball Valve Hose—60” Red Ball Valve Hose—60” Blue Compressor Indicator Light, Red Indicator Light, Amber Fan Float Chamber Relay Board Case Bottom Case Back Case Front 552701 Rev. A April 7, 2009 551196 551197 19813 19720 65360 65260 19652 111029 111030 109820 19685 19699 121840 121839 121838 CAUTION! Use only standard soap and water to clean the shroud and/or base. Industrial solvents found in most cleaners and degreasers can cause the plastic to crystallize and become brittle. 7 Troubleshooting Tips Compressor does not start Problem: Compressor circuit breaker has tripped. Solution: Depress the circuit breaker switch. Problem: HIGH PRESSURE light is on. Solution: The high side pressure switch has tripped; verify the tank and hose ball valves are open. Check tank and verify it is not full. Problem: COMPRESSOR switch is not on. Solution: Press the COMPRESSOR switch to ON. Compressor runs but does not move refrigerant Problem: The ball valves on the hoses are not open. Solution: Open the ball valves. Problem: The tank valves are not open. Solution: Open the valves. During recovery, unit shuts off on high pressure Problem: The refillable tank valves are not open. Solution: Open the tank valves. Problem: Valves on hoses are shut. Solution: Open valves. Unit will not pull down to appropriate vacuum level Problem: There is a leak in the A/C system. Solution: Fix the leak. Problem: Trapped pockets of refrigerant. Solution: Allow system to stabilize then heat with a heat gun. 8 Flow Diagram 552701 Rev. A April 7, 2009 9 Wiring Diagram 10 Conversion Table CONVERSION TABLE 552701 Rev. A April 7, 2009 OZ. LBS. 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 0.03 0.06 0.09 0.13 0.16 0.19 0.22 0.25 0.28 0.31 0.34 0.38 0.41 0.44 0.47 0.50 0.53 0.56 0.59 0.63 0.66 0.69 0.72 0.75 0.78 0.81 0.84 0.88 0.91 0.94 0.97 1 lb. 11 Warranty Robinair Limited Warranty Statement Rev. November 1, 2005 This product is warranted to be free from defects in workmanship, materials, and components for a period of one year from date of purchase. All parts and labor required to repair defective products covered under the warranty will be at no charge. The following restrictions apply: 1. The limited warranty applies to the original purchaser only. 2. The warranty applies to the product in normal usage situations only, as described in the Operating Manual. The product must be serviced and maintained as specified. 3. If the product fails, it will be repaired or replaced at the option of the manufacturer. 4. Transportation charges for warranty service will be reimbursed by the factory upon verification of the warranty claim and submission of a freight bill for normal ground service. Approval from the manufacturer must be obtained prior to shipping to an authorized service center. 5. Warranty service claims are subject to authorized inspection for product defect(s). 6. The manufacturer shall not be responsible for any additional costs associated with a product failure including, but not limited to, loss of work time, loss of refrigerant, cross-contamination of refrigerant, and unauthorized shipping and/or labor charges. 7. All warranty service claims must be made within the specified warranty period. Proof-of-purchase date must be supplied to the manufacturer. 8. Use of recovery/recycling equipment with unauthorized refrigerants or sealants will void warranty. • Authorized refrigerants are listed on the equipment or are available through the Technical Service Department. • The manufacturer prohibits the use of the recovery/recycling equipment on air conditioning (A/C) systems containing leak sealants, either of a seal-swelling or aerobic nature. • This Limited Warranty does not apply if: The product, or product part, is broken by accident. • The product is misused, tampered with, or modified. • The product is used for recovering or recycling any substance other than the specified refrigerant type. This includes, but is not limited to, materials and chemicals used to seal leaks in A/C systems. 12 Visit our web site at www.robinair.com or call our toll-free Technical Support Line at 800-822-5561 in the continental U.S. or Canada. In all other locations, contact your local distributor. To help us serve you better, please be prepared to provide the model number, serial number, and date of purchase of your unit. To validate your warranty, complete the warranty card attached to the unit, and return it within ten days from date of purchase. nationwide network of authorized service centerS If your unit needs repair or replacement parts, contact the service center in your area. For help in locating a service center, call the toll-free technical support line or visit www.robinair.com. Visite nuestro sitio web en www.robinair.com o llame sin costo a la línea de Asistencia técnica al 800-822-5561 en EE.UU. continental o Canadá. En todas las demás ubicaciones, comuníquese con su distribuidor local. Para ayudarnos a servirle mejor, tenga a mano el número de modelo, número de serie y fecha de compra de su unidad. Para validar la garantía, complete la tarjeta de garantía anexa a su unidad y enviela dentro de los diez días siguientes a la fecha de compra. RED NACIONAL DE CENTROS DE SERVICIO AUTORIZADOS Si su unidad necesita reparaciones o partes de reemplazo, comuníquese con el centro de servicio de su área. Para obtener ayuda para ubicar un centro de servicio, llame sin costo a la línea de asistencia técnica o visite www.robinair.com. Visitez notre site Web à www.robinair.com ou appelez sans frais le soutien technique au 800-822-5561 sur le territoire continental des États-Unis ou au Canada. Pour tout autre endroit, contactez votre distributeur local. Afin de nous aider à mieux vous servir, soyez prêt à nous donner le numéro de modèle, le numéro de série et la date d’achat de votre unité. Afin de valider votre garantie, remplissez la carte de garantie jointe à votre système et renvoyez-la dans les dix jours suivant la date d’achat. RÉSEAU NATIONAL DES CENTRES DE SERVICE AUTORISÉS Si votre unité doit être réparée ou à besoin de pièces de remplacement, contactez le centre de service de votre région. Pour vous aider à localiser un centre de service, appelez sans frais la ligne de soutien technique ou visitez www.robinair.com. Due to ongoing product improvements, we reserve the right to change design, specifications, and materials without notice. Debido a las constantes mejoras del producto, nos reservamos el derecho de cambiar diseño, especificaciones y materiales sin aviso. En raison des améliorations constantes apportées à nos produits, nous nous réservons le droit de changer de concept, de spécifications et de matériaux sans préavis. 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Tech Services Fax Customer Service Fax 800 412 800 800 822 690 533 322 5561 2001 6127 2890 www.robinair.com 552701 (Rev. A, April 7, 2009) © 2009 SPX
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2009:04:07 11:14:10-05:00 Creator : Adobe InDesign CS3 (5.0.4) Modify Date : 2011:01:11 12:55:24-06:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:d94adee1-ea62-c647-b2ac-51213c4a3e45 Document ID : adobe:docid:indd:b29450f1-24e1-11de-af06-9de8cf4e6766 Rendition Class : proof:pdf Derived From Instance ID : 5c602ea4-04ab-11de-b9ef-8cb19b167ca1 Derived From Document ID : adobe:docid:indd:5c602ea2-04ab-11de-b9ef-8cb19b167ca1 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 600.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 600.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:8D1DED52D64811DCABAD9529DC7DCB3E, uuid:6afc1919-2e14-11d7-a8cb-d98d03f7eec1, uuid:8D1DED52D64811DCABAD9529DC7DCB3E, uuid:BB0E0400AFE211DCB8CFFB46B143E9E8 Manifest Reference Document ID : uuid:8D1DED51D64811DCABAD9529DC7DCB3E, adobe:docid:photoshop:6afc1915-2e14-11d7-a8cb-d98d03f7eec1, uuid:8D1DED51D64811DCABAD9529DC7DCB3E, uuid:BB0E03FFAFE211DCB8CFFB46B143E9E8 Metadata Date : 2011:01:11 12:55:24-06:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 8662 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 16EXIF Metadata provided by EXIF.tools