Roche Diabetes Care 126 blood glucose meter User Manual UserManual newTeil2
Roche Diagnostics Operations, Inc. blood glucose meter UserManual newTeil2
Contents
- 1. UserManual_newTeil1.pdf
- 2. UserManual_newTeil2.pdf
- 3. UserManual_newTeil3.pdf
- 4. UserManual_newTeil4.pdf
UserManual_newTeil2.pdf
Meter Settings Target Ranges Target Ranges Your healthcare professional can tell you what blood glucose range is appropriate for you. It is very important to stay within your target range. Target Ranges can be set from a lower limit of 60–100 mg/dL to an upper limit of 101–300 mg/dL. Options Function Off Arrow symbols for above, within, or below target ranges do not appear with the blood glucose results. Single Range Set lower limit and upper limit for the target range. You will be prompted to turn on Patterns if desired (see the Patterns section of this chapter for details). 2 Ranges Set lower limits and upper limits for Before meal and After meal target ranges. You must mark your blood glucose results with a comment for the meter to detect above, within, or below Before Meal or After Meal test results (see the Adding Comments to Blood Glucose Results section in the chapter Blood Glucose Tests for details). You will be prompted to turn on Patterns if desired (see the Patterns section of this chapter for details). When Target Ranges is On, the following symbols appear with blood glucose results. Symbol Meaning The blood glucose result is below the target range. The blood glucose result is within the target range. The blood glucose result is above the target range. 47 52926_07414587001_EN.indb 47 6/2/16 2:53 PM 5 Meter Settings Target Ranges WARNING This function is no substitute for hypoglycemia training by your healthcare professional. Turn the meter on by briefly pressing . From Main Menu, press to highlight Settings. Press . Press to highlight More Options. Press . Target Ranges is highlighted. Press . Press or to highlight Off, Single Range, or 2 Ranges. Press to select an option (the example here is 2 Ranges). Press or range. Press to adjust the lower limit of the Before Meal target to set and move to the next field. Continue to set the upper limit for the Before Meal target range and the lower and upper limits for the After Meal target range. Press . 48 52926_07414587001_EN.indb 48 6/2/16 2:53 PM Meter Settings Target Ranges The appears next to the option you selected. The meter may prompt you to turn on Patterns. Press to return to the previous menu. Press to set the option and return to the previous menu (see the Patterns section of this chapter for details). Press or to highlight Yes or No. 49 52926_07414587001_EN.indb 49 6/2/16 2:53 PM 5 Meter Settings Patterns NOTE Analyzing your blood glucose results stored in the meter is an effective way for you and your healthcare professional to determine how well you are controlling your diabetes. This analysis is a valuable tool for making improvements to your diabetes management. Use care when adding comments to blood glucose results. Incorrect comments can cause inaccurate patterns to be detected by the meter when Patterns is On. Patterns A Pattern is detected by the meter when 2 below‑target (Low Pattern) or 3 above‑target (High Pattern) test results with the same comment are detected within a 7‑day period. • The meter does NOT detect a pattern for the "Other" comment added to blood glucose results. • It is very important to have the correct time and date set in the meter. Having the correct time and date setting helps ensure accurate interpretation of information by you and your healthcare professional. • Only blood glucose results marked with comments will be included in Patterns. If LO or HI test results are marked with comments, the results become part of Patterns (see the chapter Blood Glucose Tests for more details). • Target Ranges must be set in the meter to use Patterns. If Target Ranges are not set, the meter prompts you to set them. 50 52926_07414587001_EN.indb 50 6/2/16 2:53 PM Meter Settings Patterns Turn the meter on by briefly pressing . From Main Menu, press to highlight Settings. Press . Press to highlight More Options. Press . Press Press This message appears if Target Ranges is Off: Press to highlight Yes. Press Target Ranges appears on the display. (See the Target Ranges section of this chapter for details on setting target ranges). to highlight Patterns. Press to highlight On. Press to move to the option. Press . (To turn Patterns Off, select No. Press to return to Patterns.) 51 52926_07414587001_EN.indb 51 6/2/16 2:53 PM 5 Meter Settings Patterns or If Patterns is On and a new pattern is detected with a blood glucose result, a message appears on the display. to select Details to Press view the blood glucose results that make up that pattern. Press Later. to highlight View Press to return to the previous screen. 52 52926_07414587001_EN.indb 52 6/2/16 2:53 PM minders Meter Settings Reminders Reminders You can set up to 4 general test Reminders per day to remind you to test. A series of beeps sound and is displayed for Reminders set in the meter. Reminders: • turn off by inserting a test strip or pressing any button. • are postponed until the next test reminder if a test was performed within 15 minutes of a test reminder. • do not appear/beep if the meter is on at the test reminder time (including when the meter is connected to a USB cable). • do not appear/beep if the meter is connected and communicating to a Continua Certified® manager. • do not beep if the meter’s beeper is set to off. • do not appear/beep if the batteries need to be replaced. Set Reminders • Reminder times are pre-set in the meter for 8:00 am, 12:00 pm, 6:00 pm, and 10:00 pm. You may change reminder times by following the instructions below. • If a general test Reminder is set for the same time as a Post Meal reminder, the Post Meal reminder will appear/beep instead of the general Reminder (see the Post Meal Reminders section of this chapter for details). Turn the meter on by briefly pressing . From Main Menu, press to highlight Settings. Press . Press to highlight More Options. Press . Press or to highlight Reminders. Press . 53 52926_07414587001_EN.indb 53 6/2/16 2:53 PM 5 Meter Settings Reminders Pre‑set reminder times appear on the display. Press to highlight a reminder time. Press The pre‑set reminder time appears. Press or to select On or Off. Press to move to the option. To change the Reminder time shown: Press to highlight Edit time. Press . or to adjust each Press field. Press to move to the next field. Press to return to the previous menu. 54 52926_07414587001_EN.indb 54 6/2/16 2:53 PM Meter Settings Reminders indicates the reminder is set for the time shown and automatically set to On. To turn the reminder off, press to highlight Off. The reminder time appears. Press Press to continue to set additional reminders or press to return to More Options. to return to Reminders. 55 52926_07414587001_EN.indb 55 6/2/16 2:53 PM 5 Meter Settings Post Meal Reminders Post Meal Reminders Post Meal reminders can be set to remind you to test again later when you add a Before Meal comment to a blood glucose result. When a reminder occurs, a series of beeps sound and is displayed. Post Meal reminders: • turn off by inserting a test strip or pressing any button. • are postponed until the next test reminder if a test was performed within 15 minutes of a test reminder. • do not appear/beep if the meter is on at the test reminder time (including when the meter is connected to a USB cable). • do not appear/beep if the meter is connected and communicating to a Continua Certified® manager. • do not beep if the meter’s beeper is set to off. • do not appear/beep if the batteries need to be replaced. Set Post Meal Reminders • Adding a Before Meal comment to a blood glucose result sets a Post Meal reminder in the meter. • Marking blood glucose results with a Post Meal comment provides more information about your test results to help you and your healthcare professional in the management of your diabetes. • Talk to your healthcare professional to determine your Post Meal test time. • Select 1 hour, 1.5 hours, or 2 hours for Post Meal reminders to occur. 56 52926_07414587001_EN.indb 56 6/2/16 2:53 PM Meter Settings Post Meal Reminders Turn the meter on by briefly pressing . From Main Menu, press to highlight Settings. Press . Press to highlight More Options. Press . Press to highlight Post Meal. Press . 57 52926_07414587001_EN.indb 57 6/2/16 2:53 PM 5 Meter Settings Post Meal Reminders Press or to highlight On. Press to move to the option. Press Press to highlight Edit time. Press or to highlight 1 hour, 1.5 hours, or 2 hours after a meal for Post Meal reminders to occur. Press to move option. to the Press to set and return to the previous menu. 58 52926_07414587001_EN.indb 58 6/2/16 2:53 PM Meter Settings Last Result Last Result Select whether the previous blood glucose result appears with the current blood glucose result. Test results older than 24 hours do not appear. Off – only the current blood glucose result 1 appears. On – the previous blood glucose result 2 appears with the current blood glucose result. Turn the meter on by briefly pressing . From Main Menu, press to highlight Settings. Press . 59 52926_07414587001_EN.indb 59 6/2/16 2:53 PM 5 Meter Settings Last Result Press to highlight More Options. Press . Press to highlight Last Result. Press . Press or or Off. Press the option. to highlight On to move to Press to set the option and return to the previous menu. 60 52926_07414587001_EN.indb 60 6/2/16 2:53 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Modify Date : 2017:02:24 12:44:07+01:00 Create Date : 2017:02:24 12:44:05+01:00 Metadata Date : 2017:02:24 12:44:07+01:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Document ID : uuid:53936e13-2da5-41fa-afce-dce49fa2636a Instance ID : uuid:025319f3-98b5-4310-ae02-1716d314555d Producer : Adobe PDF Library 10.0.1 Page Count : 14 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools