Roche Diabetes Care 126 blood glucose meter User Manual UserManual newTeil2

Roche Diagnostics Operations, Inc. blood glucose meter UserManual newTeil2

UserManual_newTeil2.pdf

Download: Roche Diabetes Care 126 blood glucose meter User Manual UserManual newTeil2
Mirror Download [FCC.gov]Roche Diabetes Care 126 blood glucose meter User Manual UserManual newTeil2
Document ID3294129
Application IDkLtldvV18RPZei/LPYozCw==
Document DescriptionUserManual_newTeil2.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize454.29kB (5678628 bits)
Date Submitted2017-02-24 00:00:00
Date Available2017-02-24 00:00:00
Creation Date2017-02-24 12:44:05
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2017-02-24 12:44:07
Document TitleUserManual_newTeil2.pdf
Document CreatorAdobe InDesign CS6 (Macintosh)

Meter Settings
Target Ranges
Target Ranges
Your healthcare professional can tell you what blood glucose range is appropriate for you. It is very
important to stay within your target range.
Target Ranges can be set from a lower limit of 60–100 mg/dL to an upper limit of 101–300 mg/dL.
Options
Function
Off
Arrow symbols for above, within, or below target ranges do not appear with the
blood glucose results.
Single Range
Set lower limit and upper limit for the target range.
You will be prompted to turn on Patterns if desired (see the Patterns section of this
chapter for details).
2 Ranges
Set lower limits and upper limits for Before meal and After meal target ranges.
You must mark your blood glucose results with a comment for the meter to detect
above, within, or below Before Meal or After Meal test results (see the Adding
Comments to Blood Glucose Results section in the chapter Blood Glucose Tests
for details).
You will be prompted to turn on Patterns if desired (see the Patterns section of this
chapter for details).
When Target Ranges is On, the following symbols appear with blood glucose results.
Symbol
Meaning
The blood glucose result is below the target range.
The blood glucose result is within the target range.
The blood glucose result is above the target range.
47
52926_07414587001_EN.indb 47
6/2/16 2:53 PM
5
Meter Settings
Target Ranges
WARNING
This function is no substitute for hypoglycemia training by your healthcare professional.
Turn the meter on by briefly
pressing . From Main Menu,
press
to highlight Settings.
Press .
Press
to highlight More
Options. Press .
Target Ranges is highlighted.
Press .
Press
or
to highlight Off,
Single Range, or 2 Ranges.
Press to select an option (the
example here is 2 Ranges).
Press
or
range. Press
to adjust the lower limit of the Before Meal target
to set and move to the next field.
Continue to set the upper limit for the Before Meal target range and
the lower and upper limits for the After Meal target range. Press .
48
52926_07414587001_EN.indb 48
6/2/16 2:53 PM
Meter Settings
Target Ranges
The
appears next to the
option you selected.
The meter may prompt you to turn on Patterns.
Press
to return to the
previous menu.
Press to set the option and return to the previous menu (see the
Patterns section of this chapter for details).
Press
or
to highlight Yes or No.
49
52926_07414587001_EN.indb 49
6/2/16 2:53 PM
5
Meter Settings
Patterns
NOTE
Analyzing your blood glucose results stored in the meter is an effective way for you and your
healthcare professional to determine how well you are controlling your diabetes. This analysis is a
valuable tool for making improvements to your diabetes management. Use care when adding
comments to blood glucose results. Incorrect comments can cause inaccurate patterns to be detected
by the meter when Patterns is On.
Patterns
A Pattern is detected by the meter when 2 below‑target (Low Pattern) or 3 above‑target (High Pattern)
test results with the same comment are detected within a 7‑day period.
• The meter does NOT detect a pattern for the "Other" comment added to blood glucose results.
• It is very important to have the correct time and date set in the meter. Having the correct time and date
setting helps ensure accurate interpretation of information by you and your healthcare professional.
• Only blood glucose results marked with comments will be included in Patterns. If LO or HI test results
are marked with comments, the results become part of Patterns (see the chapter Blood Glucose Tests
for more details).
• Target Ranges must be set in the meter to use Patterns. If Target Ranges are not set, the meter prompts
you to set them.
50
52926_07414587001_EN.indb 50
6/2/16 2:53 PM
Meter Settings
Patterns
Turn the meter on by briefly
pressing . From Main Menu,
press
to highlight Settings.
Press .
Press
to highlight More
Options. Press .
Press
Press
This message appears if
Target Ranges is Off:
Press
to highlight Yes. Press
Target Ranges appears on the
display. (See the Target
Ranges section of this chapter
for details on setting target
ranges).
to highlight Patterns.
Press
to highlight On. Press
to move
to the option.
Press .
(To turn Patterns Off, select No.
Press to return to Patterns.)
51
52926_07414587001_EN.indb 51
6/2/16 2:53 PM
5
Meter Settings
Patterns
or
If Patterns is On and a new
pattern is detected with a blood
glucose result, a message
appears on the display.
to select Details to
Press
view the blood glucose results
that make up that pattern.
Press
Later.
to highlight View
Press to return to the
previous screen.
52
52926_07414587001_EN.indb 52
6/2/16 2:53 PM
minders
Meter Settings
Reminders
Reminders
You can set up to 4 general test Reminders per day to remind you to test. A series of beeps sound and
is displayed for Reminders set in the meter.
Reminders:
• turn off by inserting a test strip or pressing any button.
• are postponed until the next test reminder if a test was performed within 15 minutes of a test reminder.
• do not appear/beep if the meter is on at the test reminder time (including when the meter is connected
to a USB cable).
• do not appear/beep if the meter is connected and communicating to a Continua Certified® manager.
• do not beep if the meter’s beeper is set to off.
• do not appear/beep if the batteries need to be replaced.
Set Reminders
• Reminder times are pre-set in the meter for 8:00 am, 12:00 pm, 6:00 pm, and 10:00 pm. You may
change reminder times by following the instructions below.
• If a general test Reminder is set for the same time as a Post Meal reminder, the Post Meal reminder will
appear/beep instead of the general Reminder (see the Post Meal Reminders section of this chapter for
details).
Turn the meter on by briefly
pressing . From Main Menu,
press
to highlight Settings.
Press .
Press
to highlight More
Options. Press .
Press
or
to highlight
Reminders. Press .
53
52926_07414587001_EN.indb 53
6/2/16 2:53 PM
5
Meter Settings
Reminders
Pre‑set reminder times appear
on the display. Press
to
highlight a reminder time. Press
The pre‑set reminder time
appears. Press
or
to
select On or Off. Press to
move
to the option.
To change the Reminder time
shown:
Press
to highlight Edit time.
Press .
or
to adjust each
Press
field. Press to move to the
next field. Press to return to
the previous menu.
54
52926_07414587001_EN.indb 54
6/2/16 2:53 PM
Meter Settings
Reminders
indicates the reminder is
set for the time shown and
automatically set to On. To turn
the reminder off, press
to
highlight Off.
The reminder time appears.
Press
Press
to continue to set
additional reminders or press
to return to More Options.
to return to Reminders.
55
52926_07414587001_EN.indb 55
6/2/16 2:53 PM
5
Meter Settings
Post Meal Reminders
Post Meal Reminders
Post Meal reminders can be set to remind you to test again later when you add a Before Meal comment
to a blood glucose result. When a reminder occurs, a series of beeps sound and
is displayed.
Post Meal reminders:
• turn off by inserting a test strip or pressing any button.
• are postponed until the next test reminder if a test was performed within 15 minutes of a test reminder.
• do not appear/beep if the meter is on at the test reminder time (including when the meter is connected
to a USB cable).
• do not appear/beep if the meter is connected and communicating to a Continua Certified® manager.
• do not beep if the meter’s beeper is set to off.
• do not appear/beep if the batteries need to be replaced.
Set Post Meal Reminders
• Adding a Before Meal comment to a blood glucose result sets a Post Meal reminder in the meter.
• Marking blood glucose results with a Post Meal comment provides more information about your test
results to help you and your healthcare professional in the management of your diabetes.
• Talk to your healthcare professional to determine your Post Meal test time.
• Select 1 hour, 1.5 hours, or 2 hours for Post Meal reminders to occur.
56
52926_07414587001_EN.indb 56
6/2/16 2:53 PM
Meter Settings
Post Meal Reminders
Turn the meter on by briefly
pressing . From Main Menu,
press
to highlight Settings.
Press .
Press
to highlight More
Options. Press .
Press
to highlight Post
Meal. Press .
57
52926_07414587001_EN.indb 57
6/2/16 2:53 PM
5
Meter Settings
Post Meal Reminders
Press
or
to highlight On.
Press to move
to the
option.
Press
Press
to highlight Edit time.
Press or to highlight
1 hour, 1.5 hours, or 2 hours
after a meal for Post Meal
reminders to occur.
Press to move
option.
to the
Press to set and return to
the previous menu.
58
52926_07414587001_EN.indb 58
6/2/16 2:53 PM
Meter Settings
Last Result
Last Result
Select whether the previous blood glucose result appears with the current blood glucose result.
Test results older than 24 hours do not appear.
Off – only the current blood glucose result 1 appears.
On – the previous blood glucose result 2 appears with the current
blood glucose result.
Turn the meter on by briefly
pressing . From Main Menu,
press
to highlight Settings.
Press .
59
52926_07414587001_EN.indb 59
6/2/16 2:53 PM
5
Meter Settings
Last Result
Press
to highlight More
Options. Press .
Press
to highlight Last
Result. Press .
Press
or
or Off. Press
the option.
to highlight On
to move
to
Press to set the option and
return to the previous menu.
60
52926_07414587001_EN.indb 60
6/2/16 2:53 PM

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Modify Date                     : 2017:02:24 12:44:07+01:00
Create Date                     : 2017:02:24 12:44:05+01:00
Metadata Date                   : 2017:02:24 12:44:07+01:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Document ID                     : uuid:53936e13-2da5-41fa-afce-dce49fa2636a
Instance ID                     : uuid:025319f3-98b5-4310-ae02-1716d314555d
Producer                        : Adobe PDF Library 10.0.1
Page Count                      : 14
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WX3-126

Navigation menu