Rolling Code TRXC Remote Control User Manual NEW CLONER USA 300 390
Rolling Code Limited Remote Control NEW CLONER USA 300 390
User Manual
TX USA MANUAL TX USA TECHNICAL FEATURES ü Model TX USA ü 2 BATTERIES 2032 (3V) ü Frequencies 315 - 390 MHz ü 3 Channels ü Special Chip ATTENTION: THIS REMOTE WORKS IN TWO DIFFERENT WAYS: 1. ENTERING DIRECTLY THE RECEIVER 2. CLONING ATTENTION: IN TX USA (MULTICLONER) YOU CAN PUT A DIFFERENT BRAND AND FREQUENCY IN EACH BUTTON (CHANNEL) ONLY IN CLONE MODE. ENTERING DIRECTLY THE RECEIVER MODE PROGRAMMING INSTRUCTIONS 1. Locate the selector switch in the back of the remote. Pry up the cover to expose the selector switch and the hidden button, see image below. 2. Set your selector switch of 8 DIPs switch with the desired brand. See Table 1 and image below. 3. Head for your receiver, in case it has DIPs switch, this defines the code of this specific receiver, please select this same combination from the receiver in the transmitter TX USA, both must match, otherwise the communication between them will not work. In case your receiver doesn’t have this DIP selector, this section must be ignored, it is not neccessary. 4. The remote is ready to be used, press any button (from 1 to 3) please refer to your receiver’s user manual. Note: To programme BFT and MUTANCODE it will be necessary to press the hidden button (beside the switches) before pressing one ordinary button (button 1 to 3). Image to locate battery and DIP switches for selecting the brand. SPECIFIC RECEIVER’S CODE BRAND SELECTOR HIDDEN BUTTON TX USA Table 1: Entering directly the receiver. DIP SWITCHES Num Code 315 MHZ Rolling Genie Code 315 MHZ Rolling Genie Code 390 MHZ Rolling Code XT 315 RC 315 MHz Fixed Linear Code 315 MHZ Fixed HÖRMANN Code 315 MHZ Encrypted Flor-s Code 315 MHZ FAAC Need hidden button BFT MITTO Comments Rolling Original Brand Compatible R/F Nice Red LED TX USA LiftMaster Fixed Code Code 315 MHZ Fixed BILLIONCODE 10 LiftMaster BILLIONCODE 390 MHZ Liftmaster Encrypted Chamberlain Code Lobas 315 MHZ 11 Liftmaster Encrypted Chamberlain Code Lobas 390 MHZ 12 14 SOMMER code 315 FM MHZ Rolling MCT-3 Linear code 318 MHZ 13 Rolling Fixed Code Marantec 315 MHZ TX USA 15 Rolling Genie Code 315MHz Encrypted 16 Code 17 Code 390MHz Liftmaster BILLIONCODE 315MHz 18 LOBAS Fixed Liftmaster Rolling Genie Code 315MHz Mode A 19 Rolling Genie Code 315MHz Code select by position 1 to 9 on DIP12 20 21 Fixed GUARDIAN Code 303MHz Code select DIP MULTI CODE by position 1 Code 300MHz to 10 on DIP12 TX USA Code select 22 DIP LINEAR2 by position 1 Code 310MHz to 8 on DIP12 Code select 23 DIP DIGI CODE by position 1 Code 310MHz to 10 on DIP12 Encrypted Code Liftmaster LOBAS 315MHz CLONE MODE PROGRAMMING INSTRUCTIONS 1. Locate the selector switch in the back of the remote. Pry up the cover to expose the selector switch and the hidden button, see the image above. 2. Select the DIP position brand. Example: Fixed Code. 3. Press hidden button located at the back of TX USA remote, CLONER led turns on, the clone mode is activated. 4. On the CLONER remote, press the button you desire to be learnt ONCE AND RELEASE, led Lights off. 5. Close together the CLONER transmitter with the ORIGINAL transmitter. 6. Press and hold the button on the ORIGINAL transmitter until led flashes. Note: If the remote was copied correctly, the led on the CLONER will flash 3 times. To use another button, repeat steps 1 to 6. Table 2: Clone mode. TX USA Num DIP SWITCHES R/F Brand Compatible Comments SCAN MODE Universal Original Fixed Fixed Code Code 300 - 390MHz Scan ANY fixed code remote with frequency from 300 to 390 MHz. SCAN MODE V2 V2 300 - 390 MHz Scan V2 remotes that work with frequencies from 300 to 390 MHz. HCS Universal Rolling Code 300-390MHz SCAN MODE Scan ANY Rolling Code that works with frequencies from 300 to 390 MHz. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Administrator Title : NEW CLONER USA 300-390 Create Date : 2016:08:09 11:00:49+08:00 Creator Tool : pdfFactory Pro www.pdffactory.com Modify Date : 2016:08:24 16:35:20+08:00 Metadata Date : 2016:08:24 16:35:20+08:00 Producer : pdfFactory Pro 5.25 (Windows XP Professional x86 Chinese) Document ID : uuid:43ec3611-59f7-4290-bc4f-273c81541874 Instance ID : uuid:7c5397b2-aae9-4a6b-906e-2f9fc4db39b4 Page Layout : SinglePage Page Count : 7 Author : AdministratorEXIF Metadata provided by EXIF.tools