Rosslare ACQ4XXB Anti-Vandal Standalone Controllers User Manual AC Q4x Series Installation and Programming Manual
Rosslare Enterprises Ltd Anti-Vandal Standalone Controllers AC Q4x Series Installation and Programming Manual
Rosslare >
15_AC-Q42HB UserMan
AC-Q4x Series Anti-Vandal Standalone Controllers Installation and Programming Manual Models: AC-Q41HB AC-Q41HP AC-Q41SB AC-Q42HB AC-Q42HP AC-Q42SB Copyright © 2017 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE. ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual. TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS. The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE. ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact. Table of Contents Table of Contents 1. Introduction ................................................................ 9 1.1 Controller Types ...................................................................... 9 1.2 Box Content ......................................................................... 10 1.3 Ancillary Equipment .............................................................. 10 1.4 Front Panel Description .......................................................... 11 2. Technical Specifications ............................................ 12 3. Installation ................................................................ 14 3.1 Mounting ............................................................................. 14 3.2 Wiring .................................................................................. 15 3.2.1 Pre-wired Models ..........................................................................16 3.2.2 Terminal Block Models ..................................................................20 4. 4.1 Operation .................................................................. 24 Modes of Operation .............................................................. 24 4.1.1 Normal Mode ...............................................................................24 4.1.2 Secure Mode ................................................................................24 4.1.3 Bypass Mode ................................................................................24 4.2 User Levels............................................................................ 25 4.3 Switching Operational Modes ................................................ 26 4.3.1 From Normal to Secure Mode .......................................................26 4.3.2 From Secure to Normal Mode .......................................................26 4.3.3 From Normal to Bypass Mode .......................................................27 4.3.4 From Bypass to Normal Mode .......................................................27 4.4 Auxiliary Input and Output..................................................... 27 4.5 REX Button ........................................................................... 27 AC-Q4x Series Installation and Programming Manual iii Table of Contents 4.6 Tamper Feature ..................................................................... 28 4.7 Lockout Feature (Keypad/Card Tamper) .................................. 28 4.8 5. BL-D40 External Sounder ....................................................... 29 Programming ............................................................ 30 5.1 Entering the Programming Mode ........................................... 31 5.2 Exiting the Programming Mode.............................................. 32 5.3 Changing the Open Code...................................................... 32 5.4 Changing the Auxiliary Code ................................................. 33 5.5 Changing the Programming Code .......................................... 34 5.6 Changing the Normal/Secure Code ........................................ 34 5.7 Changing the Normal/Bypass Code ........................................ 35 5.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time ......................................................................... 36 5.9 Setting Auxiliary Modes ......................................................... 37 5.9.1 Auxiliary Mode 0 ..........................................................................39 5.9.2 Auxiliary Mode 1 ..........................................................................39 5.9.3 Auxiliary Mode 2 ..........................................................................39 5.9.4 Auxiliary Mode 3 ..........................................................................40 5.9.5 Auxiliary Mode 4 ..........................................................................40 5.9.6 Auxiliary Mode 5 ..........................................................................40 5.9.7 Auxiliary Mode 6 ..........................................................................41 5.9.8 Auxiliary Mode 7 ..........................................................................41 5.9.9 Auxiliary Mode 8 ..........................................................................42 5.9.10 Auxiliary Mode 9 ..........................................................................42 5.10 Keypad Heater Operation ...................................................... 43 5.11 Setting the Lockout Feature ................................................... 43 5.12 Setting the Backlight Behavior ............................................... 45 5.13 Enrolling Primary and Secondary Codes .................................. 45 iv AC-Q4x Series Installation and Programming Manual Table of Contents 5.13.1 Primary Codes Definition ..............................................................45 5.13.2 Secondary Codes Definition ..........................................................46 5.13.3 5.14 Enrolling Methods ........................................................................46 Deleting Primary and Secondary Codes................................... 49 5.14.1 Deleting Primary and Secondary Codes using the Standard Method .....................................................................................................49 5.14.2 Deleting Primary and Secondary Codes using the Code Search Method ........................................................................................50 5.15 Relay Codes Assignment........................................................ 51 5.15.1 5.15.2 Relay Code Assignment using Standard Method ..........................51 Relay Code Assignment using Search Method ..............................52 5.16 Changing PIN Code Length/Factory Default Settings ............... 54 5.17 Replacing a Programming Code ............................................. 55 5.18 Replacing a Normal/Secure Code ........................................... 55 A. Limited Warranty ...................................................... 56 AC-Q4x Series Installation and Programming Manual List of Figures List of Figures Figure 1: Front Panel........................................................................................11 Figure 2: Drilling Holes Identification ...............................................................14 Figure 3: Pre-Wired Connection for Lock Strike Relay & REX............................17 Figure 4: Pre-Wired Connection for Auxiliary Input & Output ..........................18 Figure 5: Pre-Wired Connection for the BL-D40 External Sounder ...................19 Figure 6: Connections to Terminal Blocks ........................................................20 Figure 7: Terminal Block Wiring of the Lock Strike Relay & REX .......................21 Figure 8: Terminal Block Wiring of the Auxiliary Input and Output ..................22 Figure 9: Terminal Block Wiring of the BL-D40 External Sounder .....................23 vi AC-Q4x Series Installation and Programming Manual List of Tables List of Tables Table 1: Wire Color Guide ...............................................................................16 Table 2: Programming Menus..........................................................................30 Table 3: Quick Reference Guide for Auxiliary Mode Setting .............................38 AC-Q4x Series Installation and Programming Manual vii Introduction Notice and Disclaimer This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein. BEFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES. The system must not be used for purposes other than those for which it was designed. The use of the software associated with the system and/or product, if applicable, is subject to the terms of the license provided as part of the purchase documents. ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document. This manual describes the maximum configuration of the system with the maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased. Incorrect operation or installation, or failure of the user to effectively maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury. The text, images and graphics contained in the manual are for the purpose of illustration and reference only. All data contained herein subject to change without prior notice. In no event shall manufacturer be liable for any special, direct, indirect, incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury). All graphics in this manual are for reference only, some deviation between the image(s) and the actual product may occur. All wiring diagrams are intended for reference only, the photograph or graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s). AC-Q4x Series Installation and Programming Manual Introduction 1. Introduction The AC-Q4x series are vandal resistant standalone controllers. All the units are water resistant and suitable for indoor or outdoor mounting. The unit(s) accepts up to 500 users and allows entry via a personal identification number (PIN) and/or by presenting a proximity card. 1.1 Controller Types The different types of control units described in this manual are: Type 41 – PIN only Type 42 – PIN and proximity card Type 44 – PIN and proximity card, with piezoelectric contacts Heater Relay Current Backlight Keypad Type Proximity AC-Q41HB 2A Standard AC-Q41HP 2A Standard AC-Q41SB 2A Standard AC-Q42HB 2A Standard AC-Q42HP 2A Standard AC-Q42SB 2A Standard AC-Q44 2A Piezoelectric AC-Q4x Series Installation and Programming Manual Introduction 1.2 Box Content Before beginning, verify that all of the following is in the box. If anything is missing please report the discrepancy to your nearest Rosslare Office. One controller unit Installation kit 1.3 1 drilling template (label/sticker) 1 security spline key 1 security hex screw 4 mounting screws and wall plugs Ancillary Equipment The following ancillary equipment may be required to complete your installation: Electric Lock Strike Mechanism – Fail safe (power to lock) or fail secure (power to open) Power supply with backup battery – 12 to 24 VDC (from a regulated power supply) or 16 to 24 VAC (from a transformer) Request-to-Exit (REX) button (optional) – Normally open type; switch is closed when pressed BL-D40 external sounder (optional) – Provides siren, bell, and chime Magnetic contact (optional) – Installed for door monitor capabilities 10 AC-Q4x Series Installation and Programming Manual Introduction 1.4 Front Panel Description Controls and indicators of all controller versions are identical (excluding the antenna, which is unique to Q42 and Q44) (Figure 1). Figure 1: Front Panel AC-Q4x Series Installation and Programming Manual 11 Technical Specifications 2. Technical Specifications AC-Q41HB AC-Q42HB Input Voltage ACACQ41SB Q41HP VDC VAC ACQ42SB ACQ42HP AC-Q44 12–24 VDC 12–24 VAC 16–24 VAC 12–24 VAC 16–24 VAC Maximum Input Current (12 VDC) Heater Off 130 mA 125 mA 145 mA 130 mA 145 mA 125 mA Heater On 610 mA 605 mA 625 mA 610 mA 625 mA N/A Standby Input Current (12 VDC) Heater Off 70 mA 65 mA 85 mA 70 mA 85 mA 65 mA Heater On 550 mA 545 mA 565 mA 550 mA 565 mA N/A Maximum Relay Current 2A REX Input Normally Open (dry contact) Aux. Input Max. Proximity Read Range* 12 Normally Open (dry contact) N/A 65 mm (2.5 in.) N/A 65 mm (2.5 in.) AC-Q4x Series Installation and Programming Manual Technical Specifications AC-Q41HB AC-Q42HB ACACQ41SB Q41HP ACQ42SB ACQ42HP AC-Q44 Proximity Modulation N/A ASK at 125 kHz N/A ASK at 125 kHz Proximity Card Compatibility N/A 26-Bit EM cards N/A 26-Bit EM cards LED Indicators Two tri-colored LED (Mode and Door) Operating Temp. Range -20ºC to 60ºC (-4ºF to 140ºF) Outdoor Usage Water resistant, meets IP54 Weather resistant, epoxy-potted, meets IP65 Size (H x W x T) 120 x 76 x 27 mm (4.7 x 3.0 x 1.1 in.) 120 x 76 x 22 mm (4.7 x 3.0 x 0.9 in.) 440 g (1.0 lb) 521 g (1.2 lb) Weight * Measured using a Rosslare proximity card or equivalent. Range also depends on electrical environment and proximity to metal. AC-Q4x Series Installation and Programming Manual 13 Installation 3. Installation Installation of an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader. 3.1 Mounting Prior to starting, select the location where the controller unit is to be mounted. To mount the controller: 1. Peel off the back of the self-adhesive mounting label template and place it on the required mounting location. 2. At the bottom of the unit’s case, remove the screw. 3. Carefully remove the snap-off front cover of the unit to reveal the screw holes. 4. Depending on the type of installation, gang box or panel mount, drill the respective holes in the rear cover (see Figure 2 for details). For gang box mounting, drill two holes marked “A”. For flat panel mount, drill four holes marked “B”. Figure 2: Drilling Holes Identification 14 AC-Q4x Series Installation and Programming Manual Installation The central hole, marked “C” is for routing the wiring to the controller. 5. Drill an additional 10-mm (7/16”) hole for the cable. When installing the reader on a metallic surface, cover the inside of the hole with a grommet or electrical tape. 6. Insert the unit’s cable wire into the cable hole and wire the unit as described in Section 3.2. 7. Screw the back plate into the surface. Ensure the screws are the size specified on the installation template. The unit can also be mounted using strong epoxy glue. After application, firmly hold the unit in place until the glue dries. 8. Carefully re-attach the front cover of the unit. 9. Secure the front cover by using the supplied security Torx screw. A Torx security screw tool is provided to tighten the security Torx screw. 3.2 Wiring The controllers are provided either with a pre-wired cable or with a screw-type terminal block: Pre-wired Cabling Models Terminal Block Models AC-Q41SB AC-Q41HB/HP AC-Q42SB AC-Q42HB AC-Q44 AC-Q4x Series Installation and Programming Manual 15 Installation 3.2.1 Pre-wired Models These units are supplied with a 10-conductor 60-cm (24-in.) pigtail (24-AWG cable) with exposed wires coated with solder. To wire the controller: 1. Select the appropriate connections according to Table 1. Table 1: Wire Color Guide Color Description Red V input Black Ground Green REX/BL White In/Monitor Purple Lock: Com Gray Lock: N.O. Brown Lock: N.C. Blue Aux: Com Yellow Aux: N.O. Orange Aux: N.C. 2. Prepare the secured power supply’s cable by cutting the cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”). 3. Splice the controller pigtail wires to the corresponding ancillary devices and insulate each connection, including unused wires. Refer to the wiring diagrams, depending on the desired application: 16 Wiring the Lock Strike Relay & REX (Figure 3) Wiring for Auxiliary Input & Output (Figure 4) Wiring for the BL-D40 External Sounder (Figure 5) AC-Q4x Series Installation and Programming Manual Installation Figure 3: Pre-Wired Connection for Lock Strike Relay & REX AC-Q4x Series Installation and Programming Manual 17 Installation Figure 4: Pre-Wired Connection for Auxiliary Input & Output 18 AC-Q4x Series Installation and Programming Manual Installation Figure 5: Pre-Wired Connection for the BL-D40 External Sounder AC-Q4x Series Installation and Programming Manual 19 Installation 3.2.2 Terminal Block Models These controllers come with removable terminal blocks that are pushed on pins on the motherboard of the controllers. To wire the terminal blocks: 1. Route the wires or cable through the large hole in the back cover See Figure 6. Connect the terminal blocks as shown. 2. Wire the cabling according to the following diagrams. 3. Wiring the Lock Strike Relay & REX (Figure 7) 4. Wiring for Auxiliary Input & Output (Figure 8) 5. Wiring for the BL-D40 External Sounder (Figure 9) Figure 6: Connections to Terminal Blocks 20 AC-Q4x Series Installation and Programming Manual Installation Figure 7: Terminal Block Wiring of the Lock Strike Relay & REX AC-Q4x Series Installation and Programming Manual 21 Installation Figure 8: Terminal Block Wiring of the Auxiliary Input and Output 22 AC-Q4x Series Installation and Programming Manual Installation Figure 9: Terminal Block Wiring of the BL-D40 External Sounder AC-Q4x Series Installation and Programming Manual 23 Operation 4. Operation • In the Operation chapter, “code” refers to a PIN code or proximity card depending on the unit you have. • Memory slots can be a proximity card or PIN code depending on the unit you have. 4.1 Modes of Operation The control units have three modes of operation. These are indicated by the color of the Mode indicator. 4.1.1 Normal Mode The left LED is green. Green Normal mode is the default mode. In Normal mode, the door is locked until a valid Primary code is presented to the controller. The controller can only be programmed in Normal mode. 4.1.2 Secure Mode The left LED is red. Red Only Secure and Master users can access the premises in Secure mode. A secure user must enter a primary and secondary code to gain entry. Once the primary code has been entered, the right LED flashes green for 10 seconds. During this time, the Secondary code must be entered. A Master user only needs to present the code once to gain entry. 4.1.3 Bypass Mode The left LED is orange. Orange In Bypass mode, access to the premises is dependent on whether the controller's Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation. When the Lock Strike relay is programmed for 24 AC-Q4x Series Installation and Programming Manual Operation Fail Secure Operation, the door is locked until the star button (*) is pressed. When the Lock Strike relay is programmed for Fail Safe Operation, the door is constantly unlocked. In case of power failure, once the power is restored, the controller returns to Normal mode for security reasons. 4.2 User Levels AC-Q4x series access control units accept up to 500 users and provide entry via the use of codes. Each user is allocated two memory slots: Memory Slot 1 (primary code) and Memory Slot 2 (secondary code). The way in which the two memory slots are programmed determines a user’s access level and also establishes access is granted for each of the three modes of operation. There are three user levels: Normal User A Normal user only has a Primary code and is granted access only when the controller is in its Normal or Bypass mode. Secure User A Secure user must have a primary and secondary code assigned, and the two codes must not be the same. The Secure user can gain access in any mode of operation. In Normal mode, the secure user must use the Primary code to gain entry. In Secure mode, the Secure user must first enter the Primary and then the Secondary code to gain entry. Master User A Master user must have identical Primary and Secondary codes assigned. The codes are entered with the same proximity card or the same PIN. The Master user can gain access during any mode of operation by entering the code only once. AC-Q4x Series Installation and Programming Manual 25 Operation 4.3 Switching Operational Modes The three modes of operation defined above can be changed through a few steps. 4.3.1 From Normal to Secure Mode The default factory setting for the normal/secure code is 3838. To change from Normal to Secure mode: 1. Enter the 4-digit Normal/Secure code. The left LED flashes red. Red 2. Press # to confirm the mode change. The left LED stops flashing. Red The auxiliary input of the controller can also be used to switch the mode of operation from Secure to Normal and vice versa. If the auxiliary input is selected, it de-activates the Norma/Secure mode code (see Section 5.9). 4.3.2 From Secure to Normal Mode The default factory setting for the normal/secure code is 3838. To change from Secure to Normal mode: 1. Enter the 4-digit Normal/Secure code. The left LED flashes green. Green 2. Press # to confirm the mode change. The left LED stops flashing. Green The auxiliary input of the controller can also be used to switch the mode of operation from Secure to Normal and vice versa. If the auxiliary input is selected, it de-activates the Norma/Secure mode code (see Section 5.9). 26 AC-Q4x Series Installation and Programming Manual Operation 4.3.3 From Normal to Bypass Mode By default, there is no Normal/Bypass code. The Normal/Bypass code must first be programmed to use this function (see Section 5.7 to create/modify the Normal/Bypass code). To change from Normal to By pass mode: 1. Enter the 4-digit Normal/Bypass code. The left LED flashes orange. Orange 2. Press # to confirm the mode change. The left LED stops flashing. 4.3.4 Orange From Bypass to Normal Mode To change from By pass to Normal mode: 1. Enter the 4-digit Normal/Bypass code. The left LED flashes green. Green 2. Press # to confirm the mode change. The left LED stops flashing. 4.4 Green Auxiliary Input and Output For optimum usability in different applications, the controller’s auxiliary input and output can be configured in 10 different modes of operation (see Section 5.9). 4.5 REX Button The REX button is located within the premises and is used to open the door from the inside. It is usually located in a convenient location, such as next to the door or at a receptionist’s desk. The door chime in the BL-D40 (if enabled) does not sound when the REX button is used to open the door. AC-Q4x Series Installation and Programming Manual 27 Operation The function of the REX button depends on the Lock Strike relay, whether it is programmed for failsafe or for fail secure operation. Fail Secure Operation From the moment the REX button is pressed, the door is unlocked until the Lock Strike Release time has elapsed. After this time, the door is locked, even if the REX button has not been released. Failsafe Operation From the moment the REX button is pressed, the door is unlocked until the REX button is released. In this case, the Lock Strike relay only begins its countdown once the REX button is released. This feature is designed to keep the door open, when used in conjunction with fire systems. 4.6 Tamper Feature If the controller is forcibly opened or the controller is removed from the wall, a tamper event is triggered. A tamper signal is sent to the BL-D40 external sounder. If the BL-D40 receives a tamper event signal, it activates a tamper output and a strobe light. The Siren Time can be easily programmed in the controller from 0 to 9 minutes. The tamper event can activate the auxiliary output if the controller is in Auxiliary Mode 3 (see Table 3). 4.7 Lockout Feature (Keypad/Card Tamper) If the controller is presented with wrong codes (PIN or card) consecutively several times, the unit goes into Lockout mode. When a lockout occurs, the controller keypad and reader are deactivated so no codes can be entered until the set lockout period expires. During Lockout mode, the left LED is Off, the right LED flashes red, and the controller beeps every two seconds. 28 AC-Q4x Series Installation and Programming Manual Operation 4.8 BL-D40 External Sounder The BL-D40 external sounder is designed for indoor use only and installed within the secured premises. The sounder can be powered by a 12 to 24 VDC power supply or by a 16 VAC transformer. The BL-D40 is capable of emitting four different types of audible and visual alerts: bell, chime, siren and strobe light. The bell sounds when the controller’s bell button is pressed. The door chime can be programmed to sound whenever a valid code is entered as well as for a door held open alert. The siren can be programmed to sound when the controller is tampered with (opened or removed from the wall). The length of the siren can also be programmed in the controller. The controller communicates with the BL-D40 via a Rosslare proprietary protocol. If the BL-D40 receives an unrecognized code over its communication line or communications between the controller and the BL-D40 are severed, the strobe flashes repeatedly, until the communication problem has been resolved. AC-Q4x Series Installation and Programming Manual 29 Programming 5. Programming • In the Programming chapter, “code” refers to a PIN code or proximity card depending on the unit you have. • When entering a PIN or presenting a proximity card is mentioned, the meaning may vary between units. Programming is done solely via the unit’s keypad-driven Programming Menu System. To reach the Programming Menu System, the controller must first be placed into Programming Mode (see Section 5.1). During the manufacturing process, certain codes and settings are preprogrammed. These settings are the called default factory settings. Table 2 shows all the programming menus, with default factory codes and settings. Table 2: Programming Menus Menu Description No. Default Digits Digits Digits Section 4-8 Digits Change Open code 2580 25802 258025 25802580 5.3 Change Auxiliary code 0852 08520 085208 08520852 5.4 Change Program code 1234 12341 123412 12341234 5.5 Change Normal/Secure code 3838 38383 383838 38383838 5.6 Change Normal/Bypass code NA 5.7 30 Change Door Release time 0004 5.8 Define auxiliary inputs/outputs 2004 5.9 Enable or disable keypad heater 3000 5.10 Set Lockout Feature 4000 5.11 Backlight and LED Behavior 5100 5.12 AC-Q4x Series Installation and Programming Manual Programming Menu Description No. Default Digits Digits Digits Section 4-8 Digits Enroll proximity cards, PIN or both NA 5.13 Delete proximity cards or PIN NA 5.14 Code assignment with strike/auxiliary NA 5.15 Return to factory defaults/Change PIN code Length NA 5.16 5.1 Entering the Programming Mode • The controller must be in Normal mode to enter the programming mode. • The factory default 4-digit programming code is 1234. • If a Programming code is not entered within 5 seconds, the controller returns to Normal mode. To enter Programming mode: 1. Press # twice. The left LED turns off and the right LED turns red. Red 2. Enter your 4-digit Programming code. The right LED turns green. AC-Q4x Series Installation and Programming Manual 31 Programming 5.2 Exiting the Programming Mode • Wrong entries may reset the controller back to Normal mode. • If no key is pressed for 1 minute, while in programming mode, the controller exits Programming mode and returns to Normal mode. To ex it Programming mode: 1. Press # twice to exit Programming mode at any time. You hear 3 beeps. The left LED turns green and the right LED turns off. Green Wrong entries reset the controller back to Normal mode. While in Programming mode, if no key is pressed for one minute, the unit exits Programming mode and returns to Normal mode. 5.3 Changing the Open Code The Open code is mainly used as a method to quickly test the Lock Strike relay during installation. For security reasons, when the first user is added to the controller or the Auxiliary code is changed, the default Open code is automatically deleted; non-default codes are not be erased automatically. • Open code does not function in Secure mode. • For wrong entries, you hear a long beep and the controller returns to Normal mode. • Code 0000 erases and deactivate the open code. • The factory 4-digit default setting for the open code is 2580. 32 AC-Q4x Series Installation and Programming Manual Programming To change the Open code: 1. Enter Programming mode. Green 2. Press 1 to enter Menu 1. The left LED turns red. Red Green 3. Enter the new 4-digit Open code. You hear three beeps. The system returns to Normal mode. 5.4 Green Changing the Auxiliary Code The Auxiliary code is mainly used as a method to quickly test the Auxiliary relay during installation. For security reasons, when the first user is added to the controller or the open code is changed, the default auxiliary code is automatically deleted; non-default codes are not be erased automatically. • Auxiliary code does not function in Secure mode. • Auxiliary code only works when the Auxiliary mode is 0, 1, 8 or 9. • Wrong entries return the controller to Normal mode. • Code 0000 erases and deactivates the auxiliary code. • The default 4-digit factory setting for the auxiliary code is 0852. To change the Aux iliary code: 1. Enter Programming mode. Green 2. Press 2 to enter Menu 2. The left LED turns orange. AC-Q4x Series Installation and Programming Manual Orange Green 33 Programming 3. Enter the new 4-digit Auxiliary code. You hear three beeps. Green The system returns to Normal mode. 5.5 Changing the Programming Code • The Programming code cannot be erased; the code 0000 is invalid and does not erase the Programming code. • The factory default 4-digit Programming code is 1234. To change the Programming code: 1. Enter Programming mode. Green 2. Press 3 to enter Menu 3. The left LED turns green. Green Green 3. Enter the new 4-digit Programming code. You hear three beeps. The system returns to Normal mode. 5.6 Green Changing the Normal/Secure Code • When the Auxiliary mode is 1, 2, 3 or 4, the auxiliary input takes priority over the Normal/Secure code. • Code 0000 erases and deactivates the Normal/Secure code. To change the Normal/ Secure code: 1. Enter Programming mode. Green 2. Press 4 to enter Menu 4. The left LED flashes red. 34 Red Green AC-Q4x Series Installation and Programming Manual Programming 3. Enter the new 4-digit Normal/Secure code. You hear three beeps. The system returns to Normal mode. 5.7 Green Changing the Normal/Bypass Code The Normal/Bypass code is also used to turn the door chime off and on. Chime only functions with the BL-D40 external sounder. • The chime is only heard when the Lock Strike relay is activated by a valid code entry. • Code 0000 erases and deactivates the Normal/Bypass code. To change the Normal/By pass code: 1. Enter Programming mode. Green 2. Press 5 to enter Menu 5. The left LED flashes orange. Orange Green 3. There are four different ways to program the Normal/Bypass code and door chime: Disable both Bypass code and the door chime. Enter the code 0000. Disable Bypass code and enable the door chime. Enter the code 0001. Enable Bypass code and disable the door chime. Enter any code ending with 0. Enable Bypass code and enable the door chime. Enter a code not ending with 0. You hear three beeps. The system returns to Normal mode. AC-Q4x Series Installation and Programming Manual Green 35 Programming 5.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time The default value is 0004, which corresponds to Fail Secure operation, no siren, and 4-seconds Lock Strike release time. To set the Fail Safe/ Secure Operation, Tamper Siren and Lock Strike Release Time: 1. Enter Programming mode. Green 2. Press 6 to enter Menu 6. The left LED flashes green. 3. Green Green Construct a code using the following instructions: First digit For Fail Secure Operation, the first digit should be 0. For Fail Safe Operation the first digit should be 1. Second digit Siren Time in minutes (1–9, 0 – disabled) Third and fourth digits Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released. For example, 0312 means a Fail Secure Operation consisting of a 3-minute siren and a 12-second Lock Strike release time. You hear three beeps. The system returns to Normal mode. 36 Green AC-Q4x Series Installation and Programming Manual Programming 5.9 Setting Auxiliary Modes The default auxiliary setting is 2004. Auxiliary Relay activation is subject to the user’s Auxiliary code assignment (excluding Shunt, which is activated by all users). For more details, see Section 5.15. To set Aux iliary modes: 1. Enter Programming mode. Green 2. Press 6 to enter Menu 6. The left LED flashes green. Green Green 3. Construct a code using the following instructions: Second digit (Auxiliary Mode) In addition to the Lock Strike Relay and Lock Strike REX, the unit features an Auxiliary Input. The Auxiliary mode defines the function of the Auxiliary Input. Third and fourth digits (Auxiliary Setting) Each of the Auxiliary modes has a 2-digit setting that affects how the Auxiliary mode functions (Table 3). You hear three beeps. The system returns to Normal mode. AC-Q4x Series Installation and Programming Manual Green 37 Programming Table 3: Quick Reference Guide for Auxiliary Mode Setting Auxiliary Auxiliary Mode Input Function Auxiliary Output Auxiliary Auxiliary Settings Activated by Relay (in seconds) AUX REX Valid code or AUX N.O. REX Normal/Secure Valid code switch N.O. 01 to 99 Aux. Relay Release Time 00 Aux. relay toggle Normal/Secure Star button (*) switch N.O. 01 to 99 Aux. Relay Release Time 00 Aux. relay toggle Normal/Secure Tamper event switch N.C. 01 to 99 Aux. Relay Release Time 00 Aux. relay tamper activated Normal/Secure Direct shunt switch N.O. Door Monitor Shunt N.C. 01 to 99 maximum Shunt time Door Monitor Forced door N.C. 01 to 99 Forced delay Door Monitor Door ajar N.C. 01 to 99 Ajar delay LED control – Valid code Green N.O. 01 to 99 Aux. Relay Release time 00 Aux. relay toggle LED control – Valid code Red N.O. 01 to 99 Aux. Relay Release time 00 Aux. relay toggle 38 01 to 99 Aux. Relay Release Time 00 Aux. relay toggle 01 to 99 Shunt time AC-Q4x Series Installation and Programming Manual Programming The following subsections describe each Auxiliary mode. 5.9.1 Auxiliary Mode 0 Auxiliary input function: Activates the auxiliary output Auxiliary output activated by: Valid user code, Auxiliary code, Auxiliary input For example, in Auxiliary Mode 0, the controller can function as a 2-door controller. The auxiliary relay is to be attached to the lock on the second door. The auxiliary setting defines the Door Open time for the second door. The auxiliary input is to be attached to the REX button for the second door. Door Monitor input feature for the second door is not enabled when using this mode. 5.9.2 Auxiliary Mode 1 Auxiliary input function: Toggles Normal/Secure modes Auxiliary output activated by: Valid user code, Auxiliary code For example, in Auxiliary Mode 1, the controller can function as a 2-door controller. The auxiliary relay is to be attached to the lock on the second door. REX feature for the second door is not enabled when using this mode. The auxiliary setting defines the Door Open time for the second door. The auxiliary input can switch the mode of operation of the controller between Normal and Secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode (after office hours). 5.9.3 Auxiliary Mode 2 Auxiliary input function: Toggles Normal/Secure modes Auxiliary output activated by: Star Button (*) For example, in Auxiliary Mode 2, the auxiliary relay can function as a general purpose time switch that can be activated when * is pressed. The auxiliary setting establishes for how long the auxiliary relay is to be activated. The auxiliary input can switch the mode of operation of the controller between Normal and Secure mode. By connecting a AC-Q4x Series Installation and Programming Manual 39 Programming switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode (after office hours). 5.9.4 Auxiliary Mode 3 Auxiliary input function: Toggles Normal/Secure modes Auxiliary output activated by: Alarms For example, in Auxiliary Mode 3, the auxiliary output is activated if the controller is tampered; that is, if the case is forcibly opened or removed from the wall. The auxiliary input can switch the mode of operation of the controller between Normal and Secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode (after office hours). 5.9.5 Auxiliary Mode 4 Auxiliary input function: Toggles Normal/Secure modes Auxiliary output activated by: direct shunt (explanation below) For example, in Auxiliary Mode 4, the controller is capable of bypassing an alarm zone by shunting an alarm system’s door sensor. The auxiliary output is to be wired in parallel to the door sensor output. When in use, the auxiliary output is normally open and the door sensor functions normally. When a valid code is entered, the auxiliary relay shunts the door sensor for the duration of the Shunt time, as defined by the auxiliary setting. If the door is left open longer than the Shunt time, an alarm is triggered. 5.9.6 Auxiliary Mode 5 Auxiliary input function: Door Monitor Auxiliary output activated by: Shunt (explanation below) For example, in Auxiliary Mode 5, the controller is capable of shunting an alarm system. In this mode, the auxiliary input is to be wired to the magnetic contact switch on the door. The auxiliary relay is wired to the alarm system. Without a valid code entered, the auxiliary relay matches the condition of the magnetic contact switch; if the door 40 AC-Q4x Series Installation and Programming Manual Programming opens, the auxiliary relay opens; if the door closes, the auxiliary relay closes. When a valid code is entered, a countdown for maximum Shunt time, as defined by the auxiliary setting, begins; if the door is not closed before the maximum Shunt time, the alarm is triggered. 5.9.7 Auxiliary Mode 6 Auxiliary input function: Door Monitor Auxiliary output activated by: Forced entry For example, in Auxiliary Mode 6, the controller can trigger the auxiliary relay if the door has been forced. If the Siren Settings is enabled, the siren is activated. In this mode, the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the door. The auxiliary relay is to be wired to the alarm system. If the door is forced open, the controller waits for the period of the Forced Door Delay time to elapse and then it activates the auxiliary relay. The auxiliary setting sets the forced door delay period. 5.9.8 Auxiliary Mode 7 Auxiliary input function: Door Monitor Auxiliary output activated by: Door Ajar (door held open) For example, in Auxiliary Mode 7, the controller can trigger the auxiliary relay, if it detects that the door has been held open (ajar) too long. In this mode the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the door. The auxiliary relay is to be wired to the alarm system. If the door is opened, the controller waits for the Door Ajar Delay time to elapse and if the door does not close prior to the end of this period, the controller activates the auxiliary relay. The auxiliary setting defines the Door Ajar time. If the BL-D40 External Sounder is connected in the system and a doorajar event occurs, the BL-D40 chimes every few seconds for 1 minute or until the door is closed. AC-Q4x Series Installation and Programming Manual 41 Programming 5.9.9 Auxiliary Mode 8 Auxiliary input function: Green LED control Auxiliary output activated by: Valid user code, Auxiliary code For example, in Auxiliary Mode 8, the controller can function as a 2-door controller and also provide indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the Door Open time for the second door. The auxiliary input is used to control the Door indicator. If the auxiliary input is open, the indicator flashes green; if the auxiliary input is closed, the Door indicator flashes red. This mode takes control of the Door indicator LED. The indicator LED is not lit when: • A valid code is entered • While in Secure mode, when waiting for a secondary code 5.9.10 Auxiliary Mode 9 Auxiliary input function: Red LED control Auxiliary output activated by: Valid user code, Auxiliary code For example, in Auxiliary Mode 9, the controller can function as a 2-door controller and also provide indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the Door Open time for the second door. The auxiliary input is used to control the indicator. If the auxiliary input is open, the Door indicator flashes red; if the auxiliary input is closed, the Door indicator flashes green. This mode takes control of the Door indicator LED. The indicator LED is not lit when: • A valid code is entered • While in Secure mode, when waiting for a secondary code 42 AC-Q4x Series Installation and Programming Manual Programming 5.10 Keypad Heater Operation This section is not applicable for AC-Q44 (without keypad heater). The controllers contain a built-in keypad heater. Once the heater circuitry is activated, the heater turns on when the ambient temperature drops to 4±1°C and remains on until the keypad temperature rises to 7(+2 or -1)°C. When the heater is on, the controller can operate down to an ambient temperature of -20°C. When the heater is disabled, the lowest operating temperature is 0°C. The default setting for the keypad heater is disabled state (3000). To define the key pad heater operation: 1. Enter Programming mode. Green 2. Press 6 to enter Menu 6. 3. The Mode indicator flashes green. Green Green 4. Construct a code using the following instructions: To disable the heater, the fourth digit is set to 0. To enable the heater, the fourth digit is set to 1. 5.11 Setting the Lockout Feature If the controller is presented with wrong codes (PIN or card) consecutively several times, the unit goes into Lockout mode. When a lockout occurs, the controller keypad and reader are locked so no codes can be entered until the set lockout period expires. During Lockout, the left LED is Off, the right LED flashes red, and the AC-Q4x Series Installation and Programming Manual 43 Programming controller beeps every two seconds. The default setting for the Lockout Feature is 4000 (Lockout Disabled). Using the lockout feature is highly recommended, especially when selecting to use short PIN code length (4 or 5 digits). To define the Lockout feature: 1. Enter Programming mode. Mode Door Green 2. Press 6 to enter Menu 6. The Mode indicator flashes green. Mode Door Green Green 3. Construct a code using the following instructions: Second digit Set the number of wrong code attempts, which causes a Lockout between 0 and 9 attempts. Third and fourth digits Sets the Duration of the lockout, between 00 and 99; the value is multiplied by ten, resulting in 0 to 990 seconds. 44 AC-Q4x Series Installation and Programming Manual Programming 5.12 Setting the Backlight Behavior This section is applicable for AC-Q4xHB/SB models only (backlight). The controller allows you to define the way the unit’s backlight works. To set the backlight behavior: 1. Enter Programming mode. 2. Press 6 to enter Menu 6. The left LED flashes green. Green Green 3. Enter one of the following codes: 5000 – Backlight off 5100 – Backlight on (default) 5200 – Backlight is off, activates for 10 seconds when a key is pressed, after which it dims until off 5300 – Backlight is dimmed, activates for 10 seconds when a key is pressed, after which it returns to a dimmed level 5.13 Enrolling Primary and Secondary Codes 5.13.1 Primary Codes Definition Primary codes can only be enrolled to an empty user slot, a slot with no existing Primary code in the controller’s memory. A Primary code must be unique; for instance, one user’s primary code may not be the same as that of another user. Primary codes cannot be the same as system codes, such as: the Normal/Secure code or the Open code. Users possessing a Primary code can gain entry during Normal and Bypass modes. AC-Q4x Series Installation and Programming Manual 45 Programming 5.13.2 Secondary Codes Definition Secondary codes can only be enrolled to a user slot that already includes a primary code. A secondary code need not be unique; for instance, one user’s Secondary code may be the same as that of another user. Secondary codes cannot be the same as any system codes, such as: the Normal/Secure code or the open code. Users possessing secondary codes can gain entry in any mode of operation. A secondary code can be the same as the primary code of any user. 5.13.3 Enrolling Methods There are two methods used to enroll primary and secondary codes: the standard method and the code search method. The Standard Method is used when the user slot number, for the user you wish to program, is known. You can program both primary and secondary codes using this method. The Code Search Method is mainly used when enrolling a secondary code and the user’s slot code is unknown. The code search method functions only if a user’s primary code is already enrolled and the secondary code is not. 5.13.3.1 Enrolling Primary and Secondary Codes using the Standard Method To enroll Primary and Secondary codes using the Standard method: 1. Enter Programming mode. Green 2. Press 7 to enter Menu 7. The right LED turns orange. 46 Orange AC-Q4x Series Installation and Programming Manual Programming 3. Enter the 3-digit user slot number between 001and 500 for the slot to which you wish to enroll a Primary or Secondary code. For example, User Slot 003 represents User #3. If the selected slot has no Primary code, the left LED flashes green, indicating that the controller is ready to accept a Primary code. If the selected slot already has a Primary code but no Secondary code, the left LED flashes red, indicating that the controller is ready to accept a Secondary code. If the selected slot already has a Primary and Secondary code, you hear a long beep and the controller returns to Normal mode. Gree Orange Red Orange Green 4. Perform one of the following: Enter the PIN code that you want to assign as the Primary or Secondary code for this slot number. Present your user card that you want to assign as the Primary or Secondary code for this slot number. If the PIN or user card presented is valid, the left LED stops flashing and the controller is ready for you to enter the next 3-digit slot number (refer to Step 3) for the slot to which you want to assign a code. 5. Do one of the following: Press # to move to the next available user slot number. Enter another 3-digit user slot number. If you do not wish to continue enrolling codes, press # twice and the controller returns to Normal mode. AC-Q4x Series Installation and Programming Manual 47 Programming 5.13.3.2 Enrolling Secondary Codes using the Code Search Method The code search method enables to quickly enroll a secondary code for a user whose primary code is known and whose slot number is unknown. To enroll secondary codes using the Code Search method: 1. Enter Programming mode. Green 2. Press 7 to enter Menu 7. The right LED turns orange. Orange 3. Enter 000 as the 3-digit user slot number. The right LED flashes orange. Orange The controller is now waiting for the Primary code of the user to whom you want to add a Secondary code. 4. Perform one of the following: Enter the PIN code belonging to the user for whom you wish to add a Secondary code. Present the user card belonging to the user for whom you wish to add a Secondary code. The left LED flashes red. Red Orange If the Primary code entered is not valid, you hear a long beep and the unit continues to wait for a valid Primary code. 48 AC-Q4x Series Installation and Programming Manual Programming 5. Perform one of the following: Enter the PIN code to be used as the Secondary code. Present the user card to be used as the Secondary code. If the Secondary code is valid, the controller beeps three times and returns to Normal mode. If the Secondary code is invalid, the controller sounds a long beep, and the unit continues to wait for a valid Secondary code to be entered. 5.14 Deleting Primary and Secondary Codes There are two methods to delete primary and secondary codes: a standard method and a search method. When deleting a user slot, both the primary code and the secondary code are erased. It is recommended that a record be kept of added and deleted users. This makes it easier to keep track of user slots’ status (empty or not). 5.14.1 Deleting Primary and Secondary Codes using the Standard Method To delete the Primary and Secondary codes using the Standard Method: 1. Enter Programming mode. Green 2. Press 8 to enter Menu 8. The left LED turns red and the right LED turns orange. Red Orange 3. Enter the 3-digit User Slot code you wish to delete. AC-Q4x Series Installation and Programming Manual 49 Programming The left LED flashes red indicating the controller is waiting for the Programming code to confirm the deletion. Red Orange If the user slot is empty, you hear a long beep and the unit returns to Normal mode. 4. Enter your 4-digit Programming code to confirm the deletion. If the Programming code is valid, three beeps are heard and the controller returns to Normal mode. If the Programming code is invalid, a long beep is heard and the controller returns to Normal mode. 5.14.2 Deleting Primary and Secondary Codes using the Code Search Method To delete the Primary and Secondary codes using the Code Search Method: 1. Enter Programming mode. Green 2. Press 8 to enter Menu 8. The left LED turns red and the right LED turns orange. Red Orange 3. Enter 000 as the 3-digit user slot number. The right LED flashes orange. Red Orange The controller is now waiting for the Primary code of the user you want to delete. 50 AC-Q4x Series Installation and Programming Manual Programming 4. Perform one of the following: Enter the PIN code of the Primary code belonging to the user you want to delete. Present the user card of the Primary code belonging to the user you want to delete. The left LED flashes red. Red Orange 5. Enter your 4-digit Programming code to confirm the deletion. If the Programming code is valid, you hear three beeps and the unit returns to Normal mode. If the Programming code is invalid, you hear a long beep and the unit returns to Normal mode. 5.15 Relay Codes Assignment When a primary code is enrolled for any user, the user is authorized to activate the Lock Strike relay. However, different user codes may be set to operate the auxiliary relay instead or operate both the Lock strike and auxiliary relay. Assignment of such codes is achievable for any valid user code entered in the controller. There are two methods to assign relay codes to users: a standard method and a search method. 5.15.1 Relay Code Assignment using Standard Method To assign the relay code using Standard method: 1. Enter Programming mode. Green 2. Press 9 to enter Menu 9. The left LED turns green and the right LED turns orange. Green Orange 3. Enter the 3-digit user slot for code assignment. AC-Q4x Series Installation and Programming Manual 51 Programming The left LED flashes green. Green Orange 4. Enter the assignment digit for the current user slot: 1 activates the Lock Strike relay only default 2 activates the Auxiliary relay only 3 activates the Lock Strike and Auxiliary relays If the assignment code is valid, the left LED stops flashing. The controller is now waiting for another slot number. 5. Do one of the following: Press # to move to the next available user slot number. Enter another 3-digit user slot number. If you do not wish to continue enrolling codes, press # twice and the controller returns to Normal mode. 5.15.2 Relay Code Assignment using Search Method To assign the relay code using Search method: 1. Enter Programming mode. Green 2. Press 9 to enter Menu 9. The left LED turns green and the right LED turns orange. Green Orange 3. Enter 000 for user slot access. The right LED flashes orange. 52 Green Orange AC-Q4x Series Installation and Programming Manual Programming 4. Do one of the following: Enter the PIN code of the Primary code belonging to the user you want to delete. Present the user card of the Primary code belonging to the user you want to delete. The left LED flashes green. Green Orange 5. Enter the assignment digit for the current user slot: 1 activates the Lock Strike relay only default 2 activates the Auxiliary relay only 3 activates the Lock Strike and Auxiliary relays If the assignment digit is valid, three beeps are heard and the controller returns to Normal mode. If the assignment digit is invalid, a long beep sounds and the controller waits for another assignment digit to be entered. AC-Q4x Series Installation and Programming Manual 53 Programming 5.16 Changing PIN Code Length/Factory Default Settings You must be very careful before using this command! Changing the PIN code length also erases the entire memory contents, including all user and special codes, and returns all codes to their factory default settings. To change PIN code length: 1. Enter Programming mode. Green 2. Select the desired PIN code length as follows: 00 – Returns to factory defaults and sets a 4-digit code 05 – Returns to factory defaults and sets a 5-digit code 06 – Returns to factory defaults and sets a 6-digit code 08 – Returns to factory defaults and sets a 4-8 digit code When choosing the 4–8 option, please note that you should either enter zeros before the code, or press pound at the end (for example if your code is 12345, enter either 00012345 or 12345#). Both LEDs flash red. Red Red 3. Enter your 4-digit Programming code. If the Programming code is valid, all memory is erased. You hear three beeps and the controller returns to Normal mode. If the Programming code is invalid, you hear a long beep and the controller returns to Normal mode without erasing the memory contents. 54 AC-Q4x Series Installation and Programming Manual Programming 5.17 Replacing a Programming Code The controller must be in Normal mode for the procedure to work. Ensure that the Mode indicator is green before proceeding. To replace a Programming code: 1. Remove power from the controller. 2. Press and hold the REX button. 3. Apply power to the unit with the REX button pressed. 4. Release the REX button. 5. You now have 15 seconds to program a new programming code into the unit using the initial default code before the controller reverts to the existing code. The deafult code depends on the PIN length selected (see Table 2). 5.18 Replacing a Normal/Secure Code The controller must be in its Secure mode for the procedure to work. Ensure that the Mode indicator is red before proceeding. To replace a Normal/ Secure code: 1. Remove power from the controller. 2. Press and hold the REX button. 3. Apply power to the unit with the REX button pressed. 4. Release the REX button. 5. You now have 15 seconds to use the Normal/Secure code to return to the Normal mode. 6. Once in Normal mode, enter Programming mode to program a new Normal/Secure code. The deafult code depends on the PIN length selected (see Table 2). AC-Q4x Series Installation and Programming Manual 55 A. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Clas device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio/TV technician for help. WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 56 AC-Q4x Series Installation and Programming Manual AC-Q4x Series Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com United States and Canada Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com Europe Latin America Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com China Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86 755 8610 6842 Fax: +86 755 8610 6101 support.cn@rosslaresecurity.com India Rosslare Electronics India Pvt Ltd. Tel/Fax: +91 20 40147830 Mobile: +91 9975768824 sales.in@rosslaresecurity.com Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972 3 938-6838 Fax: +972 3 938-6830 support.eu@rosslaresecurity.com CERT ISO 9001 ISO 14001 0706-0960121+05
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : sam goldberg Company : SYO Create Date : 2018:01:31 11:10:55+02:00 Modify Date : 2018:01:31 11:29:34+02:00 Source Modified : D:20180131091038 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2018:01:31 11:29:34+02:00 Creator Tool : Acrobat PDFMaker 10.0 for Word Document ID : uuid:dbd7d6bb-610b-4486-985b-c23e2a6d8dcb Instance ID : uuid:bcf2218d-d769-4f7c-a2ca-901590b28bab Subject : 66 Format : application/pdf Title : AC-Q4x Series Installation and Programming Manual Creator : sam goldberg Producer : Adobe PDF Library 10.0 Page Layout : OneColumn Page Count : 57EXIF Metadata provided by EXIF.tools