Ruckus Release Notes (September 2015) Fast Iron 08.0.61 08061 V2
FastIron 08.0.61 (GA) Release Notes FastIron_08061_ReleaseNotes_v2
2017-12-12
User Manual: Ruckus FastIron 08.0.61 Release Notes
Open the PDF directly: View PDF .
Page Count: 56
Download | |
Open PDF In Browser | View PDF |
14 August 2017 FastIron 08.0.61 for Brocade Ruckus ICX Switches Release Notes Version 2 Copyright © 2017 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, and MyBrocade are registered trademarks of Brocade Communications Systems, Inc., in the United States and in other countries. Other brands, product names, or service names mentioned of Brocade Communications Systems, Inc. are listed at www.brocade.com/en/legal/brocade-Legal-intellectual-property/brocade-legal-trademarks.html. Other marks may belong to third parties. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 2 Contents Document history ....................................................................................................................................... 4 Preface ........................................................................................................................................................ 5 Contacting Brocade Technical Support ................................................................................................... 5 Brocade resources .................................................................................................................................. 5 Document feedback ................................................................................................................................ 6 Overview ..................................................................................................................................................... 7 New in this release...................................................................................................................................... 8 Hardware ................................................................................................................................................ 8 Software features ................................................................................................................................... 8 CLI changes ........................................................................................................................................... 10 RFCs and standards ................................................................................................................................... 12 Hardware support ..................................................................................................................................... 13 Supported devices ................................................................................................................................ 13 Supported power supplies .................................................................................................................... 13 Supported optics ................................................................................................................................... 13 Software upgrade and downgrade ........................................................................................................... 14 Image file names ................................................................................................................................... 14 PoE firmware files ................................................................................................................................. 14 Defects ...................................................................................................................................................... 15 Closed with code changes in release 08.0.61 ........................................................................................ 15 Closed without code changes ............................................................................................................... 42 Known issues ........................................................................................................................................ 49 FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 3 Document history Version FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 1 Summary of changes Added description of DHCPBased VE Provisioning enhancement and made editorial changes. New enhancements and features for the 08.0.61 release. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 Publication date August 14, 2017 July 6, 2017 4 Preface Contacting Brocade Technical Support As a Brocade customer, you can contact Brocade Technical Support 24x7 online or by telephone. Brocade OEM customers should contact their OEM/solution provider. Brocade customers For product support information and the latest information on contacting the Technical Assistance Center, go to www.brocade.com and select Support. If you have purchased Brocade product support directly from Brocade, use one of the following methods to contact the Brocade Technical Assistance Center 24x7. Online Telephone Preferred method of contact for non-urgent issues: Case management through the MyBrocade portal. Quick Access links to Knowledge Base, Community, Document Library, Software Downloads and Licensing tools. Required for Sev 1-Critical and Sev 2-High issues: Continental US: 1-800-752-8061 Europe, Middle East, Africa, and Asia Pacific: +800-AT FIBREE (+800 28 34 27 33) Toll-free numbers are available in many countries. For areas unable to access a toll free number: +1-408-333-6061 Brocade OEM customers If you have purchased Brocade product support from a Brocade OEM/solution provider, contact your OEM/solution provider for all of your product support needs. OEM/solution providers are trained and certified by Brocade to support Brocade® products. Brocade provides backline support for issues that cannot be resolved by the OEM/solution provider. Brocade Supplemental Support augments your existing OEM support contract, providing direct access to Brocade expertise. For more information, contact Brocade or your OEM. For questions regarding service levels and response times, contact your OEM/solution provider. Brocade resources Visit the Brocade website to locate related documentation for your product and additional Brocade resources. White papers, data sheets, and the most recent versions of Brocade software and hardware manuals are available at www.brocade.com. Product documentation for all supported releases is available to registered users at MyBrocade. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 5 Click the Support tab and select Document Library to access product documentation on MyBrocade or www.brocade.com. You can locate documentation by product or by operating system. Release notes are bundled with software downloads on MyBrocade. Links to software downloads are available on the MyBrocade landing page and in the Document Library. Document feedback Quality is our first concern at Brocade, and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. You can provide feedback in two ways: Through the online feedback form in the HTML documents posted on www.brocade.com. By sending your feedback to documentation@brocade.com. Provide the publication title, part number, and as much detail as possible, including the topic heading and page number if applicable, as well as your suggestions for improvement. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 6 Overview Brocade FastIron Release 08.0.61 introduces the Ruckus ICX 7150 Z-Series switch, along with a continued commitment to The Effortless Network™ vision of making the network flexible, easy to manage, and cost-effective. The Effortless Network™ is enabled by Brocade® Campus Fabric, which brings campus networks into the modern era to better support mobility, security, and application agility. This evolutionary architecture integrates innovative technologies to streamline application deployment, simplify network management, and reduce operating costs. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 7 New in this release Hardware The following section lists new hardware introduced with this release as well as hardware that is not supported with this release. New switch Product name Description Product features Ruckus ICX 7150 Z-Series Switch Entry-level Stackable, 10G, and MultiGig Switch The Ruckus ICX 7150 Z-Series switch offers the following features: Full Layer 2 switching capability (4K VLANs, xSTP, Flexible Authentication, RIP Advertisement, OpenFlow 1.0 & 1.3, Static IPv4 routes) Premium Layer 3 License (OSPF v2, OSPF v3, VRRP, VRRPv3, VRRP-E, PIM-SM, PIMSSM, PIM-DM, PIM Passive) 16 2.5G+ Copper ports, that support 100M/1G/2.5G operation. 8 ports 1/10GE SFP+ Stacking/Uplink Field Install Upgrade Licenses Redundant Hot Swap Fans and Load-Sharing Power Supplies New adapter Product name Description 10G LRM Adapter 10 GE LRM SFP+ Support on ICX 7150, ICX 7250 & ICX 7750 Software features The following section lists new, modified, and deprecated software features for this release. For information about which platforms support these features, refer to the FastIron Features and Standards Support Matrix, available at www.brocade.com. New software features for 08.0.61 The following software features are introduced in this release. Support for Additional Features on the ICX 7150 o 2x10G and 4x10G Stacking o Layer 3 IP Routing features (with software license) – IPv4 and IPv6 dynamic routes, OSPF v2 & v3, PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6), PBR, Virtual Route Redundancy Protocol VRRP (IPv4), VRRP v3 (IPv6), o OpenFlow v1.0 and v1.3 o Virtual Cable Testing (VCT) DHCP-Based VE Provisioning – When the ICX device boots up in factory default mode running the Layer 3 router image, the default VE is created based on the DHCP server option (option 43) and the DHCP IP address is assigned to the VE. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 8 LAG Virtual interface – The requirement for a primary port that anchors the LAG is removed; instead, all features running over a LAG will be anchored on the LAG virtual interface. IP Source Guard (IPSG) at VLAN Level – IP source guard can be enabled on an ICX device for a range of ports in a VLAN or on the entire VLAN. IPSG scale –520 clients per interface for stacking and 256 clients per interface for SPX. On certain Brocade devices, such as ICX 7150 which have smaller TCAM, the IP source guard entries are limited to 256 entries. PVST+ protect – If a PVST+ packet is received on a port configured for MSTP, an ICX device floods it to all its ports in the VLAN so that it reaches other PVST+ devices across the VLAN. This flooding can sometimes cause a port to be blocked on the Cisco side. This feature prevents this flooding, blocking the PVST+ BPDU and marking the port as ERR-DISABLED. MSTP Root Guard – Root guard is supported for MSTP at the port level, to ensure that the port is in the designated state all the time. Protected Port – Protected ports restrict Layer 2 communication among such ports at the system level, providing isolation to end hosts. Campus Fabric Enhancements o SPX E-channel identifiers (E-CID) ping/trace – The Switch Port Extender (SPX) ping command has been added to assist in data port troubleshooting. o ZTP enhancements – Zero-touch and SPX interactive-setup have enhancements to harden the discovery process as of FastIron release 08.0.61. Zero touch provisioning was hardened to drop user traffic until the discovery of the new units is complete. To enhance troubleshooting, new show commands are also introduced. o EEE support on SPX – In addition to standalone and stacking environment, Energy Efficient Ethernet (EEE) is supported on SPX environment. When ICX7450 and ICX7250 platforms are used as a port extender (PE), the EEE feature can be configured from Control Bridge (CB) unit. DHCP static MAC address to IP address mapping – Based on the client MAC-address you can statically configure the IP address to the MAC address in the DHCP server. This configuration is useful when you need to have selected clients assigned with particular IP addresses from the server. Whenever a DHCP discover message is received from these clients, based on the static configuration, the IP address will be assigned with the other required parameters. DHCP options 43 and 60 – ICX devices running as DHCP servers can be configured with Option 43 and Option 60. DHCP option 60 helps in identifying the incoming DHCP client. If the vendor class ID advertised by the DHCP client matches with the DHCP server, the server makes a decision to exchange the vendor-specific information configured as part of DHCP Option 43. supportSave for SCP – supportSave utility added for SCP. PoE Overdrive – PoE overdrive feature allows the Class 0 and Class 4 PoE-powered device to negotiate for power greater than 30-watt allocation in 2-pair wire mode. The maximum power that can be processed based on LLDP negotiation is limited to the hardware capability of the power-sourcing equipment. This feature is supported only with ICX 7150-48ZP and Ruckus APs. The supported AP is R720 with release 3.5.1 or later. Flexible Authentication Enhancements FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 9 o o o o o Critical Voice VLAN – Voice VLAN configuration facilitates the continued functioning of Voice over IP (VoIP) phones when external server authentication or authorization fails. Reauthentication with dead RADIUS server – To detect dead RADIUS servers, you can configure regular monitoring that begins at system startup. Multiple IPv6 addresses with dynamic ACLs – Up to four IPv6 addresses are supported with dynamic ACLs. Additional RADIUS attributes– Acct-Terminate-Cause, Class, Framed-IPv6-Address and Idle-Timeout. Colon-separated MAC address format for MAC authentication CLI changes The following section lists new, modified, and deprecated commands for this release. New commands in 08.0.61 The following commands are new in this release: auth-timeout-action authentication voice-vlan clear pvst-plus-protect-statistics enable nd hop-limit errdisable recovery ignore-temp-shutdown inline power overdrive interface lag lacp-mode lag-mac mstp root-protect timeout protected-port pvstplus-protect show hardware ipv6-route show hardware route show ip arp inspection show license installed show mstp root-protect show protected-port show pvstplus-protect show spx csp show spx debug show spx zero-touch ipc show spx zero-touch log show spx zero-touch status spx ping FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 10 system-max l3-interface voice-vlan Modified commands in 08.0.61 The following commands have been modified in this release: auth-fail-action (flexible authentication) clear access-list accounting copy flash flash default-ports inline power install-firmware inline power install-firmware scp ip dhcp-client enable ip rip prefix-list ip route ip rip route-map ipv6 route ipv6 route next-hop ipv6 route next-hop-enable-default ipv6 route next-hop-recursion lag license install perpetual mac-authentication password-format mka-cfg-group multi-stack-port multi-stack-trunk poison-reverse prefix-list (RIP) pvst-mode regenerate-seq-num reload ring interfaces show access-list accounting show acl-on-arp show configuration show dot1x sessions show hardware mac entry show inline power debug-info show inline power emesg show ip dhcp snooping info show mac-authentication sessions show running-config show running-config interface ethernet FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 11 show span vlan show stack show statistics show statistics dos-attack show spx show spx-mon show version show vlan source-guard enable tagged Several commands have been updated to include Ethernet LAG ID options. Please refer to the Brocade FastIron Command Reference. Deprecated commands in 08.0.61 The following commands have been deprecated in this release: chassis fanless-mode-enable (replaced by chassis fanless) deploy ip dhcp-client discovery-interval ip dhcp-client continuous-mode max-duration primary-port show spx zero ipc (replaced by show spx zero-touch ipc) static ethernet tag-type uplink-switch RFCs and standards The following RFCs and standards are newly supported in this release: IEEE 802.3bz – 2.5GBASE-T FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 12 Hardware support Supported devices The following devices are supported in this release: Brocade Ruckus ICX 7150 Series (ICX 7150-C12P, ICX 7150-24, ICX 7150-24P, ICX 7150-48, ICX 7150-48P, ICX 7150-48PF, ICX 7150-48ZP) ICX 7250 Series (ICX 7250-24, ICX 7250-24G, ICX 7250-24P, ICX 7250-48, ICX 7250-48P) ICX 7450 Series (ICX 7450-24, ICX 7450-24P, ICX 7450-32ZP, ICX 7450-48, ICX 7450-48F, ICX 7450-48P) ICX 7750 Series (ICX 7750-26Q, ICX 7750-48C, ICX 7750-48F) Supported power supplies For a list of supported power supplies, refer to the Data Sheet for your device. Data Sheets are available online at www.brocade.com. Supported optics For a list of supported fiber-optic transceivers that are available from Brocade, refer to the latest version of the Brocade Optics Family Data Sheet available online at www.brocade.com. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 13 Software upgrade and downgrade Image file names Download the following images from www.brocade.com. Device ICX 7150 Boot image file name mnz10110.bin ICX 7250 spz10110.bin ICX 7450 spz10110.bin ICX 7750 swz10110.bin Flash image file name Router:SPR08061.bin Switch:SPS08061.bin Router:SPR08061.bin Switch:SPS08061.bin Router:SPR08061.bin Switch:SPS08061.bin Router:SWR08061.bin Switch:SWS08061.bin PoE firmware files The following tables lists the PoE firmware file types supported in all 08.0.61 releases. The firmware files are specific to their devices and are not interchangeable. For example, you cannot load ICX 7250 firmware on an ICX 7450 device. Note: The PoE circuitry includes a microcontroller pre-programmed at the Brocade factory. The software can be loaded as an external file. The initial release of the microcontroller code is still current and does not need to be upgraded. The PoE firmware version string will be kept updated to match the corresponding FastIron software version; however, this is only a cosmetic change, and the firmware itself remains unchanged. If a new version of the code is released, Brocade will notify its customers of the needed code upgrade. Finally, in the remote case that a failure occurs during an upgrade process, the switch would still be functional but without PoE circuitry. If you encounter such an issue, please contact Brocade Technical Support. Table 1 PoE firmware files Device Firmware version File name ICX 7150 1.8.8 fw Icx7xxx_poe_01.8.8b001.fw ICX 7250 1.8.8 fw Icx7xxx_poe_01.8.8b001.fw ICX 7450 1.8.8 fw Icx7xxx_poe_01.8.8b001.fw FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 14 Defects Closed with code changes in release 08.0.61 This section lists software defects with Critical, High, and Medium Technical Severity closed with a code change as of 6-July-2017 in 08.0.61. Defect ID: DEFECT000574969 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.40 Technology: Traditional Stacking Symptom: If there are continuous traffic to L3 hosts connected on stack and ingress port is on standby or member units, then every one minute there will be 1 or 2 packets drop(depends on traffic rate) Condition: 1: There are continuous traffic to L3 hosts connected on Router stack. 2: Ingress port is on standby unit or member unit. 3: Traffic rate is around 5% or more. Defect ID: DEFECT000593233 Technical Severity: High Probability: Low Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.60 Technology: NTP - Network Time Protocol Symptom: NTP Clock when receives with wrong reference clock from the server (CVE-2016-1551) NTP packet when received with origin timestamps, leads to NTP associations are demobilized (CVE2016-4953, CVE-2015-8139) ICX device sometimes leads to crash, when crafted packet received with hmode > 7 in peer association(CVE-2016-2518) Spoofed crypto packet sometimes, demobilize the NTP client associations (CVE-2016-1547). Condition: Patch for vulnerability issues : 1. CVE-2016-1551 2. CVE-2016-4953, CVE-2015-8139 3. CVE-2016-2518 4. CVE-2016-1547 Recovery: User can re-configure a new NTP server in ICX Defect ID: DEFECT000597195 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: RIP - IPv4 Routing Information Protocol Symptom: No, big impact to the customer. More control packets are trapped to the CPU even when the associated VE Router interface is deleted or IP address is un-configured. Condition: None. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 15 Defect ID: DEFECT000599682 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: Windows PC does not get 802.1x authenticated when FI device has auth-timeout action configured as success and RADIUS tines-out. . Condition: 802.1x is enabled on an interface connected to Windows PC supplicant and the auth-timeout action is configured as success. Defect ID: DEFECT000607508 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: ACLs - Access Control Lists Symptom: ACL's are not effective for PE ports immediately after the system reload and also a specific PE reload. Condition: 1) Scaled IPv4 ACLs should present i.e. each ACL should have at least 900 filters or more. 2) Large ACL should be applied on port. Workaround: If configuration contains large ACL definitions and if they are not used remove them. Recovery: System auto recovers after certain time depending on the number of ACL rules configured. And the maximum noticed time is about ~13 minutes. Defect ID: DEFECT000610871 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.50 Probability: Medium Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: Few entries are not getting updated in v6 snooping table but v6 sessions are bound. Condition: When there are 10 DHCP hosts and v6 snooping tables are not updated. Defect ID: DEFECT000612108 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.50 Technology: PoE/PoE+ - Power over Ethernet Symptom: 'show inline power emesg' displays only local unit events. Condition: Remote unit poe events cannot be displayed from Active Unit of stack system using 'show inline power emesg' Workaround: Do a rconsole to remote unit or connect to remote unit console to get the poe events displayed for that remote unit. Recovery: Defect ID: DEFECT000613148 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.50 Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: SNMPv3 traps are not generated after switchover or failover during ISSU. Condition: Upon switchover or failover during ISSU SNMPv3 traps are not seen. Recovery: There are 2 ways to recover from this issue: 1. Restart the SNMP trap receiver. 2. Disable checking "time window" for SNMPv3, if the trap receiver tool supports it. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 16 Defect ID: DEFECT000616647 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: IP Source Guard Symptom: Removing a vlan using command 'no vlan' is leading to stale IPSG entries (IPSG entries on a given vlan are removed when the VLAN is deleted). Condition: IP Source-guard is enabled on member ports of a VE port. User VRF is enabled on the VE port. VLAN (corresponding to the VE port) is deleted using 'no vlan ' Workaround: Remove the VRF setting from VE Remove the config on VE interface (no int ve) Remove the vlan (no vlan ) Give a few seconds (around 20 seconds) time gap between executing two commands. Defect ID: DEFECT000617855 Technical Severity: High Probability: Low Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.50 Technology: Static Routing (IPv4) Symptom: When maximum (2K) IPv4 Static Routes are configured on a scaled SPX-System, High CPU might be experienced for some period. Condition: When the customer reports High CPU/sluggish CLI on a SPX-System after creation of around 2K static routes. Defect ID: DEFECT000619315 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Using 'no authentication' leaves a port in dynamic VLAN Symptom: Condition: A Client is authenticated and port is dynamically added to a VLAN. Now if all Flexible authentication are removed using 'no authentication', port is not removed from the Dynamic VLAN, even though session for the client is removed. Defect ID: DEFECT000619420 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Symptom: Users' counts is not not in sync after switch-over Condition: 1)Bring up 1020 dot1x sessions on a PE port 2)Issue "show dot1x sess br" 3)Execute a switch-over and issue command from step 2 again on new Active However, the output from step-3 is not in sync output from step-2 Workaround: No workaround FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 17 Defect ID: DEFECT000620652 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Symptom: Users fail to authenticate when STP is enabled on dynamic VLAN Condition: User is trying to authenticate using dot1x and Radius server provides dynamic VLAN as part of AAA-ACCEPT message. If the Dynamic VLAN has STP enabled, then the User fails to authenticate Workaround: Works with RSTP and issue is seen only with STP (legacy) Defect ID: DEFECT000623517 Technical Severity: Medium Probability: High Brocade FastIron OS Product: Technology Group: Stacking Reported In Release: FI 08.0.50 Technology: Mixed Stacking Symptom: Error message - "Invalid device number for ACL stacking buffer" seen along with stack trace Condition: Seen under certain conditions during a SPX Reload and DOS Attack configuration Defect ID: DEFECT000623569 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: MAC Port-based Authentication Symptom: A Webauth Client gets Authenticated without a RADIUS returned ACL attribute, and then a second client gets authenticated with RADIUS returned ACL. At this time, first user's Session gets removed and needs to be authenticated again. Condition: One or more users get authenticated without an ACL attribute in the radius profile followed by a user with ACL attribute. Recovery: Authenticate the first user again Defect ID: DEFECT000624291 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.60 Technology: Hardware Monitoring Symptom: On ICX7150 unit when the 1G access port is disabled and enabled then the adjacent next port drops the traffic for a very short time duration around 20 milli-seconds. The traffic resumes after that short time Condition: The issue happens on ICX7150 units 1G access port when it is disabled and enabled then the adjacent next port encounters this issue Defect ID: DEFECT000624655 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.40 Technology: CLI - Command Line Interface Symptom: Loss of text in the output of commands executed from telnet terminal. Condition: When the ICX is accessed via its telnet server and then its telnet client is used to connect to another device, loss of text can be observed in the output of commands run on that other device. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 18 Defect ID: DEFECT000626010 Technical Severity: High Probability: Low Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: ACLs - Access Control Lists Symptom: ACL entries are missed upon reload with the error : Error: ACL operation failed since filter id exceeds allowed maximum.Please try regenerate-seq-num. Condition: Running regenerate sequence number command with a gap value less than default which can result in sequence numbers exceeding the maximum value if the gap value were to default. Here is an example: ACL_1: sequence 10 permit x.x.x.x any permit y.y.y.y any permit z.z.z.z any Regenerate sequence number: regenerate-sequence-number 64995 1 ACL_1: 64995: permit x.x.x.x any 64996: permit y.y.y.y any 64997: permit z.z.z.z any The above ACL_1 on reload will result in not adding filter number 2 and 3 since first filter starts with sequence number 64995 and adding the default gap(10) results in sequence number 65005 which is greater than the maximum allowed value. Workaround: When specifying the gap value smaller than default ensure the resultant sequence numbers would still fit if the gap value were to be default value. Defect ID: DEFECT000626028 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Stack traces and error messages seen on Active and Standby Units Symptom: Condition: While executing CLI command "no mac-auth enable all" Workaround: No workaround Defect ID: DEFECT000626459 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: MAC Port-based Authentication Symptom: Flexauth port stays in dynamic VLAN after disabling MAC authentication Condition: After successful mac-authentication is done, disable mac-authentication from the port Workaround: Reload the device to effect the change after doing a "wr mem" Recovery: Reload the device to effect the change after doing a "wr mem" FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 19 Defect ID: DEFECT000626847 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Mixed Stacking Symptom: In the scaled campus fabric setup, sometime show command output for Flexible authentication feature is not complete and have only partial output . Also CLI response slowness is observed during the command execution. Condition: The partial command output and CLI response slowness is observed only with the scaled campus fabric setup which has more than 4 control bridges and 30 port extender nodes. Workaround: Retry the flexible authentication show command when output is partial. Defect ID: DEFECT000627372 Technical Severity: Medium Probability: High Brocade FastIron OS Product: Technology Group: Layer 2 Switching Reported In Release: FI 08.0.50 Technology: VLAN - Virtual LAN Symptom: SPX PE port is assigned to dynamic VLAN even when it is not supposed to be assigned Condition: Observed when 'max-vlans' under port has reached the configured limit before authentication Defect ID: DEFECT000627486 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: RADIUS Symptom: Sometimes, even when a RADIUS server is available, the dead-RADIUS server logic may detect the server unavailable and subsequent authentication requests could time out and the timeout action is taken. Condition: None Workaround: Remove the RADIUS server and add it back again. Defect ID: DEFECT000627499 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.40 Technology: Hardware Monitoring Symptom: On ICX7450 and ICX7250 running system when the USB drive is inserted then sometimes the USB file system does not get mounted and the files are not accessible Condition: This issue happens on ICX7450 and ICX7250 when USB drive is inserted in a running system Workaround: After reload the USB drive is mounted correctly and files are visible after that Recovery: This works fine after switch reload Defect ID: DEFECT000628361 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: IP Multicast Reported In Release: FI 08.0.60 Technology: MLD - Multicast Listener Discovery Some of the well-known IPv6 multicast addresses like ff05::1:3 are being mld-snooped. It applies to Symptom: both dynamic as well as static entry creation. Condition: Customer may observe mld-snooping on some well-known IPv6 multicast addresses. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 20 Defect ID: DEFECT000630003 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.60 Technology: UDLD - Uni-Directional Link Detection Symptom: UDLD enabled ports moving to link disabled state with stack unit priority change followed by switchover. Condition: If an older standby is selected as standby again (due to a priority change for the stacking member) then the UDLD enabled ports go to Link disabled state after switchover. Defect ID: DEFECT000630173 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: ACLs - Access Control Lists Symptom: When MLD snooping is enabled with VLAN range command with continuous traffic through an ICX device high CPU condition will happen. Condition: 1) At least 100 VLANs with range command is configured with MLD snooping. 2) Per VLAN 18 multicast flows are present. 3) IPv6 ACL is present on the port Recovery: Unbind and bind the ACL on the port. Defect ID: DEFECT000630312 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: DHCP Client is wrongly configured with ip-address 0.0.0.0 Condition: When management interface is Up, DHCP Client receives address 0.0.0.0. Works fine, when management interface is disabled FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 21 Defect ID: DEFECT000630434 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Traditional Stacking Symptom: status of some units in linear stack shows: Synchronizing (st=8) Enter command "show stack", the stack info would shows like: mailto:[STBY]local-3@ICX7150-C12 Router#show stack T=1h16m59.7: alone: standalone, D: dynamic cfg, S: static ID Type Role Mac Address Pri State Comment 1 S ICX7150-24 member 00e0.5200.0100 0 remote Synchronizing (st=8) 2 S ICX7150-48P member 748e.f882.e418 0 remote Synchronizing (st=8) 3 S ICX7150-C12P standby cc4e.2408.d465 0 local Ready 4 S ICX7150-24P active cc4e.24b4.729c 0 remote Ready active standby +---+ +---+ +---+ +---+ | 2 |3/3--3/1| 4 |3/3--3/1| 3 |3/2--3/1| 1 | +---+ +---+ +---+ +---+ Condition: 1, linear stacking 2. the beginning/end unit of the stack has only one stacking port configured. Workaround: configure with both stacking ports in each unit. "write mem" and "reload" may be needed. Recovery: configure with both stacking ports in each unit. "write mem" and "reload" may be needed. Defect ID: DEFECT000630511 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Security Technology: AAA - Authentication, Authorization, and Accounting Symptom: AAA for SSH login does not fail-over to local account when TACACS+ key mismatched between FI and the tacacs server Condition: When FI device is configured with both local and TACACS+ authentication. TACACS+ key mismatch happens. Workaround: NO Defect ID: DEFECT000630684 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: OSPF - IPv4 Open Shortest Path First Symptom: OSPF Router LSAs are present in incorrect areas, where the links don't exist. Condition: Router LSA for an interface configured under Area 1. Defect ID: DEFECT000630960 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: DoS (Denial of Service) protection Symptom: Traffic leak might be observed on ICX7x devices, if an interface port security is enabled with age 0. Condition: On FI 7X platforms, 1. Enable Port security on an interface with age 0 2. Configure Secured macs 3. Tag multiple ports to same vlan. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 22 Defect ID: DEFECT000631080 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Mixed Stacking Symptom: On ICX7250 when the switch is upgraded from 8.0.50 or earlier release to 8.0.60 release image then in some of the cases the existing POD license file gets deleted. This is a very corner case and happens only in some units Condition: This happens on ICX7250 switch when it is upgraded from 8.0.50 or earlier release to 8.0.60 release image then this issue is observed in some units Defect ID: DEFECT000631474 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: PoE/PoE+ - Power over Ethernet Symptom: Unexpected reset seen on active unit of a stack during a reload of PE Condition: PE Reload Defect ID: DEFECT000631665 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Stack Failover/Switchover Symptom: Residual entries in Member unit TCAM which could potentially impact traffic through this unit Condition: Observed after an ISSU upgrade to a newer image Defect ID: DEFECT000632033 Technical Severity: Low Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.30 Technology: Port Mirroring Symptom: Even if the size limit in "debug packet-capture mode pcap-fmt " is greater than 60 bytes, captures of outgoing packets are still limited to 60 bytes. Condition: When "debug packet-capture mode pcap-fmt " is limit to 60 bytes. Defect ID: DEFECT000632408 Technical Severity: Low Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.40 Technology: Port Mirroring Symptom: The output of "debug packet-capture mode pcap-fmt" is corrupted. Specifically, a timestamp appears before every single packet byte. Condition: In debug packet mode, select pacap-fmt mode and set limit for it (1-65535). Then while we capturing packets, we can see every byte is getting timestamp in output. Defect ID: DEFECT000632465 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer FI 08.0.30 Reported In Release: Technology: OSPF - IPv4 Open Shortest Path First Symptom: OSPF intra-routes are not installed in IP routing table when intra-area routes and area range configuration in the ospf area are for same IP Prefix. Condition: IP Unicast traffic loss as IP route points to drop next-hop Workaround: Remove & add the area range configuration. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 23 Defect ID: DEFECT000632718 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Symptom: An unauthenticated entry is created along with an authenticated entry for same mac-auth user Condition: When the user tries to do mac-authetication Defect ID: DEFECT000632719 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Symptom: Residual Filter entry in TCAM corresponding to a mac-authenticated user Condition: After clearing the session for user who is authenticated using mac-authentication. This is observed in scaled setup. Defect ID: DEFECT000632720 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: MAC Port-based Authentication Symptom: Radius server Timeout is observed Condition: When user is trying to do authentication using mac-auth Defect ID: DEFECT000632888 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.60 Technology: Software Installation & Upgrade Symptom: Boot Configuration - "boot system flash secondary" config is not synced to standby unit Condition: The issue is seen upon a ISSU upgrade, when a ISSU Secondary is executed Workaround: Manually configure "boot system flash secondary" in the secondary Defect ID: DEFECT000633181 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: IP Source Guard Symptom: IPSG residual entries remain in tables after removing the VLAN of which the LAG interface is a member Condition: Seen in Switch image. IPSG is enabled on primary port of a LAG and the ports are part of a vlan. DHCP snooping/IPSG entries are learnt on the primary port of LAG. Vlan is removed Workaround: Clear the IPSG entries or unconfigure IPSG config on the primary port, before removing the vlan FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 24 Defect ID: DEFECT000633185 Technical Severity: Critical Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Probability: High Technology Group: IP Multicast Technology: IGMP - Internet Group Management Protocol Symptom: ICX7xxx would sometime reset upon doing a switchover. Condition: - ICX7xxx product running switch image - Switchover and failover operation on stack - IGMP configured on the vlan Workaround: no work around available Recovery: no recovery plan available. Defect ID: DEFECT000633402 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Security Technology: AAA - Authentication, Authorization, and Accounting Symptom: Authorization and accounting fail-over to the next method fails, when authenticated via fail-over action in key mismatching scenario between server and device. Condition: SSH authorization and accounting fails with key mismatch. Defect ID: DEFECT000633563 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: QnQ - IEEE 802.1Q Symptom: When VLAN bridging is configured, the unicast pacekts destined to the management VLAN via nonmanagement VLAN port is dropped. Condition: When loopback cable is connected between management VLAN and non-management VLAN, the unicast packets destined to the management VLAN via non-management VLAN port is dropped. Defect ID: DEFECT000634055 Technical Severity: High Probability: High Brocade FastIron OS Product: Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Mixed Stacking Symptom: In the scaled campus fabric topology, some times ACL rules are missing in some of the port extenders after repeated reload of entire stack. Condition: ACL rules are missing in some of the port extenders with repeated entire stack reload is observed only with the scaled campus fabric topology which has more than 4 control bridges and 36 port extender nodes. Defect ID: DEFECT000634334 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: LAG - Link Aggregation Group Symptom: LACP flap might be observed when range of interface is disabled. Condition: 1. Configure lacp-timeout-short. 2. Configure MCT. 3. Disable a range of 48 interfaces. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 25 Defect ID: DEFECT000634343 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Mixed Stacking Symptom: in SPX chain when one ICX7450-32ZP Port Extender switch using 2.5G port connects to another ICX7450 port extender switch using its 1G port then the port extender switch does not join the SPX setup. Condition: This issue happens when ICX7450-32ZP 2.5G port is connected to ICX7450 1G port in the SPX chain Defect ID: DEFECT000634354 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Monitoring FI 08.0.60 Reported In Release: Technology: Hardware Monitoring Symptom: In the ICX7250 switch when the 10G SFP+ optics is inserted to module 2 ports then sometime the error message is seen on output. Condition: The issue is seen when 10G SFP+ is inserted in ICX7250 switch module 2 ports at run time. Defect ID: DEFECT000634418 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: IP Addressing Symptom: On Fast Iron platforms, Directed broadcast/WOL packets might not work when using VRF Condition: On ICX devices, when VRF is part of two VEs, then with intervlan routing WOL/directed broadcast packets will not be received. Defect ID: DEFECT000634552 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking FI 08.0.60 Reported In Release: Technology: Mixed Stacking Symptom: After failover, PE can not attach to CB. Condition: PE attached to failover unit can not re-attach after switchover and Failover. Recovery: Reload whole SPX Defect ID: DEFECT000634632 Technical Severity: Medium Probability: Low Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: xSTP - Spanning Tree Protocols Symptom: MSTP BPDU's might not be forwarded after enabling loop-detection in the default VLAN. Condition: 1.Configure the port connected to third party vendor switch as dual-mode port and enable MSTP. 2. Disable MSTP on the ICX7250 Brocade switch. 3. Enable loop-detection in default VLAN of ICX7250 . 4. MSTP BPDU packets might be dropped. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 26 Defect ID: DEFECT000634706 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Mixed Stacking Symptom: In SPX setup PE detaches every 40 minutes and connects back when ACL logging is configured on PE interfaces with continuous logging traffic. Condition: 1) ACL logging is enabled on PE interface(s) with active ACL binding. 2) Traffic matching the logging criteria is continuous and at least 5000 packets/sec. Workaround: 1) Disable ACL logging when not in use. 2) Limit/apply rate limiting for the logging traffic below 4k packets/sec to make room to the LLDP keep alive packets and other control packets which can compete with logging packets. Defect ID: DEFECT000634739 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: xSTP - Spanning Tree Protocols Seeing error state "vlan_set_l2intf_stp_state(vlan_idx=1,pport=1/1/1,state=UNKNOWN,T=1097) Symptom: stg_id=5, get GALNET_STP_DISABLED & ERROR STATE" on STBY unit after Condition: downgrade from 8060 to 8030m Workaround: No workaround Recovery: No functional issue if no switchover is triggered after downgrade. Defect ID: DEFECT000634937 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: SDN Reported In Release: FI 08.0.40 Technology: OpenFlow Symptom: When greater than 100 Openflow flows in the system, if controller deletes flows beyond the 100, there is a TCAM leak. Condition: 1) Total flow count should be >100 2) Delete the flows beyond the first 100. Recovery: Use "clear openflow all" command to cleanup the stale TCAM entries. Defect ID: DEFECT000635080 Technical Severity: Critical Probability: Low Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: CLI - Command Line Interface Symptom: ICX may unexpectedly reload, when CLI command with more than 256 characters is executed on the terminal [Console or TELNET or SSH] Condition: When executing CLI command with more than 256 characters in a Console or TELNET or SSH session. Workaround: Avoid CLI commands of size 256 characters or above. Defect ID: DEFECT000635492 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.50 Technology: LAG - Link Aggregation Group Symptom: ICX7450 goes for unexpected reload. Condition: In ICX7450, when a port is configured as dual-mode and connected to the Aerohive AP, the switch goes for reload in every few minutes. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 27 Defect ID: DEFECT000635671 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: MCT - Multi-Chassis Trunking Symptom: In ICX7750-26Q unit when the 40G Breakout command is configured then some of the port's MAC address assigned is same as the others Condition: The issue happens on ICX7750-26Q unit when the Breakout is configured through command line Defect ID: DEFECT000635709 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Stack Management Symptom: The system resets with a stack trace showing rel_ipc_receive_msg_callback() Condition: When the reliable IPC receives a reset signal (TCP reset), a pointer may be set to NULL before accessing it. This causes crash. The reliable receives reset only when it tries to reconnect a broken session. Workaround: There is no workaround. When this happens, the unit reloads. Recovery: The unit reloads. Defect ID: DEFECT000635787 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Traditional Stacking The ICX 7150 may becomes a member when downgrading to 8.0.60 from 8.0.61. However, release Symptom: 8.0.60 does not support ICX7150 stacking. Therefore, it gets stuck, and cannot be converted back to standalone mode. Condition: The described problem happens when downgrading to 8.0.60. The fix in 8.0.61 is to prevent future release downgrade to 8.0.61. The bug can only be fixed in 8.0.60 patch. It cannot be fixed in 8.0.61. Workaround: There is no workaround. Most stacking CLIs are blocked for ICX7150 in 8.0.60. The ICX7150 must run 8.0.61, do "stack unconfigure me" and become a standalone. Then, it can run 8.0.60. Recovery: Must reload the unit using 8.0.61 image. Then, when it boots up as a member, type "stack unconfigure me" to remove the stacking related flash. It becomes a standalone. Then it can reload with 8.0.60 image. Defect ID: DEFECT000635966 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.40 Technology: PoE/PoE+ - Power over Ethernet Symptom: Unexpected reload when installing an unsupported PoE firmware file. Condition: PoE Firmware download Defect ID: DEFECT000636212 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Stack Management Symptom: The system resets with a stack trace showing rel_ipc_receive_msg_callback() Condition: When the reliable IPC receives a reset message from its peer, it sets a pointer NULL before accessing it. This causes the unit to reload. The reliable IPC rarely receives reset signal. It happens only when reliable IPC tries to reconnect a broken session due to some error. Workaround: No workaround is available. The unit reloads. Recovery: The units reloads. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 28 Defect ID: DEFECT000636385 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: IP Multicast Reported In Release: FI 08.0.61 Technology: IPv4 Multicast Routing Symptom: L3 IP Multicast forwarding entries (routes) are not getting programmed causing traffic drop. Condition: Applicable to all ICX7xxx products, when ospf flaps on a PIM Router where the route to source/RP are same. This issue is seen when the LHR is loosing the route to source and relearning the route again. The upstream router to RP and source is same. In such a scenario the LHR generates (s,g) join (*,g) join with (s,g, rpt) prune and also (s,g) prune which is incorrect. In working condition the LHR should never generate the (s,g) prune when the route is learnt. Workaround: no workaroud Recovery: clear ip pim mcache on both router Defect ID: DEFECT000636592 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Traffic Management Reported In Release: FI 08.0.61 Technology: Rate Limiting and Shaping Symptom: BUM syslog notification is not generated when configured BUM rate-limit is higher than BUM packet receiving rate on the port. Condition: BUM syslog notification feature is enabled on the interface. BUM traffic is received at higher rate than configured rate-limit. Defect ID: DEFECT000636620 Technical Severity: High Probability: Low Product: Brocade FastIron OS Technology Group: IP Multicast Reported In Release: FI 08.0.61 Technology: IPv6 Multicast Routing Symptom: Rarely when L3 multicast flow getting learnt system will reset. Condition: Applicable to all ICX7xxx products, with L3 Multicast configuration and continuous traffic. Problem is seen during system reload. Workaround: No workaround Recovery: No workaround Defect ID: DEFECT000636643 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: MCT - Multi-Chassis Trunking Symptom: In MCT setup if a port is configured as MCT client first and then LACP is configured on the port ,the client Lag port will be shown as Err/Blocked. Condition: MCT Cluster with a LACP Client . Recovery: On MCT cluster device configure client port as part of LACP first and then configure the same as MCT client . Defect ID: DEFECT000636714 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security FI 08.0.50 Reported In Release: Technology: 802.1x Port-based Authentication Symptom: Authentication fails when users connect on a port that is enabled after disabling Condition: Disabling the port and re-enabling the port results in this issue. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 29 Defect ID: DEFECT000636715 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: 802.1x Port-based Authentication Symptom: In stacking or SPX system, MAC movement across ports on remote unit is not working Condition: An Authenticated User moving across Ports on a remote unit Defect ID: DEFECT000636754 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: xSTP - Spanning Tree Protocols Symptom: ERROR!!! rstp_port_class is NULL, this_stp=0, on console Condition: When enable or disable stacking Workaround: There is no work around Recovery: Reload the system Defect ID: DEFECT000636776 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: HTTP/HTTPS Symptom: Certificate generation with private key file of size 4096 bits is unsuccessful with error "Cert import failed....Could not parse the PEM-encoded import data". Condition: Attempt to generate certificate with size 4096 bits key. Defect ID: DEFECT000636821 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: xSTP - Spanning Tree Protocols Symptom: Though the MAC authentication gets succeeded, MAC learning will not happen on auth-default-vlan. Condition: 1. Enable both MSTP and MAC Authentication on an edge port 2. MAC authentication Succeeds. Defect ID: DEFECT000636903 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: CLI - Command Line Interface Symptom: ICX unexpectedly reloads when authenticating [Console/Telnet/SSH] user credentials with Radius server. Condition: ICX unexpectedly reloads when AAA method is set to Radius and user authentication is done using Radius server. Defect ID: DEFECT000637202 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.40 Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: Device might reload unexpectedly during snmpwalk/snmpbulkwalk. Condition: 1.Load an image without .bin extension in image name 2.Configure snmp-server community strings and enable the snmp-server 3.Perform ISO snmpwalk/snmpbulkwalk on brcdSPXOperUnitBuildlVer / brcdSPXOperUnitImgVer FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 30 Defect ID: DEFECT000637334 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: xSTP - Spanning Tree Protocols Symptom: Port State in "show interface" is wrong Condition: The port is untagged, enable spanning tree on a VLAN which is the port's default VLAN. Workaround: There is no work around. Recovery: There is no recovery, no functional impact also. Defect ID: DEFECT000637356 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: Openflow flows gets missed in hardware after controller connection is lost and re-established. Condition: 1) There should be an active connection with controller. 2) And the connection to the controller is flapped Defect ID: DEFECT000637461 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: MAC Port-based Authentication Symptom: Unexpected reload of Active Unit of an ICX stack with authentication enabled Condition: This is observed when Radius server is not configured but mac-authentication is enabled. And then User is attempting a mac-authentication. Defect ID: DEFECT000637602 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.60 Technology: High Availability Symptom: The ICX device reloads unexpectedly. Condition: The ICX devices are connected in stack. Packet received in non-member unit of the stack that need to be forwarded to the active unit. Defect ID: DEFECT000637960 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Probability: Low Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: DHCP snooping entries learnt on the switch are lost after reloading the ICX stack followed by switchover. Condition: DHCP snoop entries are learnt by ICX stack. ICX stack is reloaded and some unit(s) are not ready by the time standby election happens. This is followed by a switch-over and the DHCP snoop entries learnt by the stack are lost on New Active unit. Defect ID: DEFECT000637965 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: IP Multicast Reported In Release: FI 08.0.61 Technology: IPv6 Multicast Routing Symptom: Assertion message on the login session appears when a IPV6 address on Layer 3 router interface is configured with the interface value greater than 1026. Condition: On ICX7150 devices configuring an IPV6 address on a Layer 3 router interface whose interface value is greater than 1026 can result in assertion message. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 31 Defect ID: DEFECT000638000 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.40 Technology: RMON - Remote Network Monitoring Symptom: In SNMP table, the value of snChasFan2OperStatus (OID 1.3.6.1.4.1.1991.1.1.1.3.2.1.4.2.1) returns the wrong value for standby or member units in a stacking system. The value returns other(1) if the fan status is normal for standby or member units in a stacking system. The correct return value in this case should be normal(2) Condition: It happens always Workaround: User can use CLI command “show chassis” to display the fan status for all unit s in a stacking system Recovery: none Defect ID: DEFECT000638069 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.50 Probability: Medium Technology Group: Monitoring Technology: RAS - Reliability, Availability, and Serviceability ICX7450 or ICX7250 crashes while running 8040/8050/8060 image. Symptom: Condition: The CPU sample feature is trying to decode the call trace, which is causing the crash to occur when it is trying to decode the stack trace Workaround: Disable the Auto CPU Sample feature by executing the following commands in each of the unit console: dm cpu sample auto off Recovery: Disable the Auto CPU Sample feature by executing the following commands in each of the unit console: dm cpu sample auto off Defect ID: DEFECT000638087 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: IP Addressing Symptom: In FastIron products, dynamic gateway obtained from DHCP is stored wrongly in startup config. Condition: In Fastiron products, obtain the dynamic gateway via DHCP server and do "write memory" will lead to writing a wrong gateway in startup configuration file. Defect ID: DEFECT000638331 Technical Severity: Critical Product: Brocade FastIron OS Reported In Release: FI 08.0.60 Probability: High Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: The ICX device reloads unexpectedly. Condition: When upgrading the code on DHCP-Server enabled ICX device, the device reloads unexpectedly. Defect ID: DEFECT000638365 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: Management GUI Symptom: Interface ports are down when LRM adaptor is plugged in ICX device and accessed using HTTP/HTTPS. Port down syslog message are observed. Condition: Connect ICX via HTTP/HTTPS and modify the LRM interface speed in ethernet interface page. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 32 Defect ID: DEFECT000638439 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Configuration Fundamentals Symptom: The UP link might get bounced, creating a temporary loss of connectivity to the switch. Condition: The condition is observed only when all the data ports on the device are disabled at once. Defect ID: DEFECT000638482 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: Medium Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: DHCP Client is not getting IP address from the Server. Condition: When the DHCP client sends DHCP Discover with option 50 (requesting for a particular IP) and if that IP address is excluded in the pool, the client is not getting IP assigned. Defect ID: DEFECT000638508 Technical Severity: Medium Probability: Low Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: 802.1x Port-based Authentication Symptom: Issue will be observed on the ports of a new unit that joins the stack and in dynamic mode . Condition: STP port priority is not set to default value for ports of newly joined unit . Workaround: After a unit joins the stack do a reload before changing the configuration on the ports of newly joined unit in the stack . Recovery: change the stp port priority to default using the CLI : spanning-tree Ethernet priority 128 Defect ID: DEFECT000638525 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.30 Technology: Stack Management Symptom: The ICX-7450 Running-config Update failure on stacked environment from USB disk. Condition: The condition is seen only when Running-config copied from USB stick for stacked environment. But Works fine for Single Unit. Defect ID: DEFECT000638699 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: Active unit crashes while detaching large ACL from VE that has PE ports with ACL accounting and logging enabled Condition: 1) ACL should be large ie with more than 1000 filters. 2) ACL accounting is enabled on all/most filters. 3) ACL logging is enabled on all/most filters. 4) ACL logging traffic should present. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 33 Defect ID: DEFECT000638737 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: LAG - Link Aggregation Group Symptom: DEFECT DOES NOT EXISTIt IN PREVIOUS VERSIONS OF SOFTWARE Condition: DEFECT DOES NOT EXISTIt IN PREVIOUS VERSIONS OF SOFTWARE Defect ID: DEFECT000638743 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: LAG - Link Aggregation Group Symptom: DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE Condition: DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE Defect ID: DEFECT000638751 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching FI 08.0.61 Reported In Release: Technology: LAG - Link Aggregation Group Symptom: DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE Condition: DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE Defect ID: DEFECT000638774 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring Symptom: On the ICX7150 platform 1Gig copper ports if the port speed downshift is configured at 10Mbps speed then if VCT (Virtual cable testing) command is run then the port goes down and then comes up in 1Gbps speed despite downshift configuration being there Condition: On the ICX7150 platform 1Gig copper ports if the port speed downshift is configured at 10Mbps speed then if VCT (Virtual cable testing) command is run then the port goes down and then comes up in 1Gbps speed despite downshift configuration being there Workaround: This issue happens on the ICX7150 platform 1Gig copper ports if the port speed downshift is configured and then if VCT (Virtual cable testing) command is run Defect ID: DEFECT000638967 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: SDN Reported In Release: FI 08.0.60 Technology: OpenFlow Symptom: Openflow flow that is received with priority greater than 32768 does not work. Condition: 1. Openflow feature is enabled on the interface. 2. Openflow flows with priority greater than 32768 is received. Defect ID: DEFECT000639200 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: The fan speed change trap messages are still seen in trap receiver when trap is disabled Condition: 1.Disable the fan speed change trap 2. View the fan speed change trap messages in trap receiver FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 34 Defect ID: DEFECT000639224 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: IP Source Guard Symptom: With the IPSG enabled configuration, standby crashes on bootup Condition: 1) IPSG is enabled on stack units Defect ID: DEFECT000639432 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: UDLD - Uni-Directional Link Detection Symptom: LAG ports are getting flap during the SNMPWALK of the MAUMIB Condition: 1).Configure the LAG 2).Enable the UDLD 3).Perform the parallel SNMPWALK of the 'ifMauAutoNegTable', 'ifMauTable' 4).Lag ports getting flapped with following SYSLOG messages. SYSLOG: <14> Jun 1 06:08:15 Port 1/1/29 : MODULE-UDLD : PORT-DOWN (Reason : RemSeq Unchanged Exceed Max-Limit) SYSLOG: <14> Jun 1 06:08:15 Port 1/1/29 : MODULE-UDLD : PORT-DOWN (Reason : No Receive Exceed Max-ReTry) SYSLOG: <14> Jun 1 06:08:15 System: Interface ethernet 1/1/29, state down SYSLOG: <14> Jun 1 06:08:15 System: Logical link on interface ethernet 1/1/29 is down. Defect ID: DEFECT000639436 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: IP Multicast Reported In Release: FI 08.0.30 Technology: PIM - Protocol-Independent Multicast Symptom: L3 IP Multicast traffic drop. Condition: Applicable on all ICX7xxx products, with PIM configured and IP Multicast traffic. Seen in a specific topology viz. active-receiver----ve17-Router1-ve9---- Router2 Router3--ve7--Router2 (RP)--ve7--Router4--ve7---- source (same vlan domain) Workaround: configure large prune-wait interval. Recovery: Configure large prune-wait interval Defect ID: DEFECT000639439 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.61 Technology: IP Addressing ISSU will abort due to protocol sync not complete as seen in show issu status. Symptom: Condition: Applicable to all ICX7xxx products, during ISSU configuration. This problem is seen occasionally. Workaround: NO workaround FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 35 Defect ID: DEFECT000639636 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.60 Technology: NTP - Network Time Protocol Symptom: Unexpected reload of the device when NTP is enabled. Condition: NTP is enabled. NTP loses synchronization with all configured NTP servers. Defect ID: DEFECT000639786 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: SSH - Secure Shell Symptom: ICX may unexpectedly reload, when SSH session gets terminated with SSH key exchange in progress. Condition: Disconnecting SSH session, while supportsave with scp is in progress or initiating SSH session from secureCRT terminal and disconnect immediately. Defect ID: DEFECT000639822 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: ICX device sends accounting interim packet with service-type attribute as Call-Check instead of Framed-user. Condition: 802.1x authentication and interim-accounting are enabled on interface. The device sends interimaccounting to the RADIUS server. Defect ID: DEFECT000640587 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.40 Probability: Medium Technology Group: Monitoring Technology: RAS - Reliability, Availability, and Serviceability Symptom: ICX7450 or ICX7250 crashes while running 8040/8050/8060 image. Condition: The CPU sample feature is trying to decode the call trace, which is causing the crash to occur when it is trying to decode the stack trace Workaround: Disable the Auto CPU Sample feature by executing the following commands in each of the unit console: dm cpu sample auto off Recovery: Disable the Auto CPU Sample feature by executing the following commands in each of the unit console: dm cpu sample auto off Defect ID: DEFECT000640719 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: CLI - Command Line Interface Symptom: Static gateway configuration is lost from the running configuration. Condition: Overwriting dynamic gateway with same static gateway, followed by static IP address configuration in the device. Workaround: Remove dynamic ip address before configuring the static gateway or configure the static ip address before configuring static gateway. Recovery: Reconfigure the static gateway to recover the loss of static gateway FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 36 Defect ID: DEFECT000640964 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: Re-authentication triggered by restricted Client is not working Condition: User is already in restricted vlan. Then if User triggers dot1x re-authentication request, it is getting ignored by ICX Defect ID: DEFECT000641072 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Traditional Stacking Symptom: On ICX7250 stack environment with EEE (energy efficient ethernet) configured, when the standby unit is reloaded then the CPU utilization goes high to 99% and console access is stuck for some time Condition: This issue happens on ICX7250 stack environment with EEE (energy efficient ethernet) configured and standby unit is reloaded Defect ID: DEFECT000641307 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: xSTP - Spanning Tree Protocols Symptom: Hardware STP state and Software STP state is out of sync. Condition: When unconfig the topology group's master VLAN. Workaround: There is no work around. Recovery: Reset the system. Defect ID: DEFECT000641415 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.60 Technology: Hardware Monitoring Symptom: On ICX7250 switch when the external USB device is inserted to the switch then some times the device is not detected. The USB device gets detected and and mounted after the unit reload. Condition: This issue happens only sometimes on the ICX7250 when external USB device is inserted to the up and running system Workaround: The attached USB device gets detected and mounted after a reload is performed to the ICX7250 unit Defect ID: DEFECT000641644 Technical Severity: Medium Probability: Low Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: CLI - Command Line Interface Symptom: In the ICX7150 stacking environment, if number of power supplies is equal to one then PoE capability(PoE/Regualr) is not displayed under PSU details info of member unit Condition: This issue happens on ICX7150 stacking environment if the number of power supplies is equal to one FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 37 Defect ID: DEFECT000641931 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: MCT - Multi-Chassis Trunking Symptom: In MCT cluster when a MCT peer reboots then joins back, we might see multicast traffic loss for up to 125sec (for default query interval time) on some receivers connected to a MCT client until the next IGMP/MLD query is sent. Condition: - v4/v6 Multicast snooping is configured on vlan - Multicast source and receivers (IGMP/MLD) are on different MCT clients. - In MCT cluster when a MCT peer reboots and then joins back (or CCP Up event) Workaround: By configuring the IGMP/MLD query interval to the smaller value, we can limit the traffic loss only to that interval time Recovery: The problem will recover automatically once the next query is sent out. To speed up the recovery, try configuring the IGMP/MLD query interval to the smaller value Defect ID: DEFECT000641986 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.30 Technology: sFlow SFLOW collector reports length mismatch error. Symptom: Condition: SFLOW version 5 is enabled. The SFLOW packet contains default-gateway information. Defect ID: DEFECT000642325 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: Even after disabling the fan traps, they are observed in the trap receiver. Condition: 1.Disable fan-speed-change trap and fan-failure trap using, no snmp-server enable traps fan-failure no snmp-server enable traps fan-speed-change 2.Traps seen in trap receiver when disabled Defect ID: DEFECT000642551 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.60 Probability: High Technology Group: Layer 2 Switching Technology: VSRP - Virtual Switch Redundancy Protocol Symptom: The ICX device might reload unexpectedly. Condition: The commands 'no router vsrp' and 'show ip' are executed in sequence on ICX device. Defect ID: DEFECT000642713 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: CoA response is sent to RADIUS with source IP address not honoring "ip radius source-interface" command. Condition: CoA feature is enabled. "ip radius source-interface" command is configured. ICX device receives CoA-Request. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 38 Defect ID: DEFECT000642973 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: The ICX device reloads randomly while issuing 'show mac-authentication session all' command. Condition: 1. The ICX devices are in stack. 2. MAC-authentication is enabled on port in non-active unit. 3. 'show mac-authentication session all' command is executed. Defect ID: DEFECT000642998 Technical Severity: High Probability: Low Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.50 Technology: PoE/PoE+ - Power over Ethernet Symptom: PoE feature is non-functional after downgrading from 8061 to previous releases. Condition: Image Downgrade Workaround: "no inline power" for all ports and then reload the unit. After reload, install different FW version. Recovery: "no inline power" for all ports and then reload the unit. After reload, install different FW version. Defect ID: DEFECT000643357 Technical Severity: Critical Probability: High Brocade FastIron OS Product: Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring Symptom: When the ICX7450 using copper downlink port connects to the printer and the interface is configured n half-duplex mode then over a period of multiple iterations sometimes the ping from ICX7450 to the printer fails Condition: This issue happens when ICX7450 connects to a printer using downlink copper port configured in half-duplex mode Defect ID: DEFECT000643449 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.50 Technology: Mixed Stacking Symptom: The CB unit (ICX 7750) connected to a PE (ICX 7450) in a SPX environment might reload unexpectedly. Condition: The condition is seen only when there is packet corruption observed on the SPX ports of the PE. Defect ID: DEFECT000643568 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Stack Failover/Switchover Symptom: Device may unexpectedly reload during standby election Condition: Reload stack setup or standby election, with CLI command history in persistant log Workaround: Clear CLI command history before stack reload or before standby election FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 39 Defect ID: DEFECT000643626 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: MCT - Multi-Chassis Trunking Symptom: MCT peer cluster MAC is learnt on a CCEP port. Condition: Reload of MCT cluster nodes. Workaround: There is no workaround. Recovery: Stop all customer traffic and reload MCT cluster nodes. Since this issue is timing related, if issue is seen after reload of MCT cluster nodes, the only option is to wait for the MCT cluster MACs to age out at CCEP ports. Defect ID: DEFECT000643744 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: MAC Port-based Authentication Symptom: Fallback to mac-authentication does not happen for remote unit port on Stacking/SPX system Condition: User is connected to DUT through remote unit port and is non-dot1x capable. However, macauthentication does not get triggered even after timeout happens for dot1x authentication Defect ID: DEFECT000643843 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring Show memory command in ICX 7150 shows inaccurate information Symptom: Condition: When show memory is used to view the memory statistics on ICX 7150 Defect ID: DEFECT000644097 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Traditional Stacking Symptom: Stacking configuration is not removed during a downgrade to 8060 from 8061, though 8060 does not support 7150 stacking Condition: During a Downgrade from 8061 to 8060 on a ICX 7150 Stack Defect ID: DEFECT000644169 Technical Severity: High Probability: High Brocade FastIron OS Product: Technology Group: Security Reported In Release: FI 08.0.60 Technology: MAC Port-based Authentication Symptom: Mac-authentication is not getting triggered when configured value of 'tx-period' is 3 sec Condition: User is dot1x not-capable and 'tx-period' is configured as 3 sec. However, User is not falling back to mac-authentication after timeout happens for dot1x authentication. Instead session is getting cleared for the User Defect ID: DEFECT000644439 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: xSTP - Spanning Tree Protocols Symptom: System memory depletion with syslog or specific syslog message type is disabled. Condition: When syslog feature is disabled or a particular syslog message type is disabled, memory depletion is encountered. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 40 Defect ID: DEFECT000645534 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.60 Probability: High Technology Group: Security Technology: AAA - Authentication, Authorization, and Accounting Symptom: Telnet user authentication is configured. Telnet to switch results in the following: 1. The line "Please Enter Password:" is printed in the same line as "Please Enter Login Name:" 2. The telnet password is not hidden and printed. Condition: If the customer is using a 8061 beta build, it gets exposed to this issue. Recovery: Upgrade to 8061 released image or a patch build with the defect fix. Defect ID: DEFECT000645619 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: xSTP - Spanning Tree Protocols Symptom: Occasionally ICX7250 1G access ports not going down after disabling the link partner's port. And port remains up even though link partner state is down. Condition: This issue is specific to ICX7250 1G access ports and not observed with uplink or stacking ports. Also it requires repeated port disable and enable on the link partner to see this issue. Workaround: Disable and re-enable ICX7250 1G port which has this issue to recover from the error state. Defect ID: DEFECT000645659 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Traditional Stacking Symptom: The statistics counters are not updated correctly. This issue is seen only internal releases and was fixed in the final release Condition: Issue " show interfaces" command Recovery: none FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 41 Closed without code changes This section lists software defects with Critical, High, and Medium Technical Severity closed without a code change as of 6-July-2017 in 08.0.61. Medium Defect ID: DEFECT000550376 Technical Severity: Reason Code: Design Limitation Probability: Low Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Configuration Fundamentals Symptom: The ports will go down if there a cable cut/fault cable. This issue is present only on 10G fiber ports of on ICX7450 platform. Condition: If there is a TX/RX fiber cable cut, the link fault-signalling will not work and the ports will go down. Fault indication will not be reflected on port status. Workaround: Use good quality fiber cable and keep protected. Recovery: Replace the fiber cable. Medium Defect ID: DEFECT000600081 Technical Severity: Reason Code: Not Reproducible Probability: Low Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.40 Technology: Syslog Symptom: MAU mib table ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits OIDs always return the 00, 01 Condition: Perform the SNMPWALK of the MAU table snmpwalk -v2c -c public 1.3.6.1.2.1.26.5.1.1.9.1 snmpwalk -v2c -c public 1.3.6.1.2.1.26.5.1.1.10.1 Defect ID: DEFECT000616501 Reason Code: Feature/Function Not Supported Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Medium Technical Severity: Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: ifDescr OID does not display LAG name during SNMPWALK and returns "No such instance message for lag interface". hq1-up-swe-10{22}: snmpwalk -v2c -c public 172.26.70.222 ifDescr IF-MIB::ifDescr.83886043 = No Such Instance currently exists at this OID Condition: SNMPWalk for ifDescr on ICX device with LAG configured. High Defect ID: DEFECT000629959 Technical Severity: Reason Code: Design Limitation Probability: Medium Product: Brocade FastIron OS Technology Group: SDN Reported In Release: FI 08.0.60 Technology: OpenFlow Symptom: In ICX7750 sometimes the tagged ARP packets does not egress out when the flow is pointed to the select group Condition: This happens on ICX7750 with tagged ARP packets when the flow is pointed to the select group FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 42 Low Defect ID: DEFECT000632032 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.30 Technology: Port Mirroring Symptom: In the ICX6450 switches when the command "debug packet-capture mode pcap-fmt" with "debug destination telnet" is run then some packet drop is observed Condition: This issue happens on ICX6450 switches when the command "debug packet-capture mode pcap-fmt" with "debug destination telnet" is run Low Defect ID: DEFECT000632120 Technical Severity: Feature/Function Not Supported High Reason Code: Probability: Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: VLAN - Virtual LAN Symptom: During reload of the device, the ports which were member of the IP-SUBNET VLAN might not be present and IP-SUBNET VLAN might not be formed. Condition: 1. Create IP-SUBNET VLAN whose member should be enabled with MAC-Authentication. 2. Reload the device High Defect ID: DEFECT000632721 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.50 Technology: MAC Port-based Authentication Symptom: Failover to second radius server does not work Condition: When large number of users try to do mac-auth and first Radius server is down, but second radius server is up High Defect ID: DEFECT000632722 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Management FI 08.0.50 Reported In Release: Technology: NTP - Network Time Protocol Symptom: Show running configuration does not hold the timezone Michigan configured in ICX Condition: Under certain unknown conditions. High Defect ID: DEFECT000633023 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.60 Technology: LAG - Link Aggregation Group Symptom: Lag deployments having ports from Module-2(10G), were 10G speed capability is subjected to license availability, on system reload Lag will be un-deployed if the 10G license is removed after successfully configuring the LAG. Condition: LAG deployment using ports from Module-2(10G), were 10G license was available when LAG ports were configured and subsequently before deploy if 10G license is removed. Deploy command will go through, but 10G ports without the license will not come up physically. Also on reload this LAG will be un-deployed to difference in configured port speed between the ports in the Lag. Workaround: User should apply Sica 8*10G license so as to bring the ports UP which are from module 2 and part of an deployed LAG FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 43 High Defect ID: DEFECT000633890 Technical Severity: Reason Code: Will Not Fix Probability: Medium Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Configuration Fundamentals Symptom: In one of the ICX7750 unit it was observed that the switch went for one time reload without any event or trigger Condition: This is a very rare case that happened in ICX7750 switch while operating normally High Defect ID: DEFECT000633909 Technical Severity: Reason Code: Not Reproducible Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.60 Technology: Stack Management Symptom: Sometimes the ICX7450 switch running as a part of stack shows up error messages related to "soc_ser_correction". This happens in a rare corner case. Condition: This issue is a corner case and seen with the ICX7450 switch running as a part of stack for some time High Defect ID: DEFECT000634757 Technical Severity: Reason Code: Will Not Fix Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: xSTP - Spanning Tree Protocols Symptom: In FastIron products, LAG ports stp states moving to blocked state when cross unit lag between ICX 7750 and ICX 7450 is reloaded Condition: In Fasttiron Products, configuring cross unit lag between ICX 7750 and ICX 7450 and then reload the device will lead to LAG stp states moving to blocking state and LAG down. High Defect ID: DEFECT000635170 Technical Severity: Already Fixed in Release High Reason Code: Probability: Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.30 Technology: Traditional Stacking Symptom: ICX Stack breaks unexpectedly. Condition: When SFLOW forwarding is enabled on LAG ports and also SFLOW collector is connected through the management port, ICX stack gets broken unexpectedly. High Defect ID: DEFECT000635207 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: High Availability Symptom: The ports on the SXL 2X10G management line card might not come up. Condition: The 10G ports on the 2X10G management line card, when connected to any peer end port might not come up. High Defect ID: DEFECT000635681 Technical Severity: Not Reproducible High Reason Code: Probability: Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: Static Routing (IPv4) Symptom: BUM traffic is not flooded in the route-only ports after un-configuring route-only feature on the interface. Condition: 1. Configure route-only on an interface. 2. Reload the device 3. Unconfigure route-only on the interface. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 44 High Defect ID: DEFECT000636450 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: xSTP - Spanning Tree Protocols Symptom: In SXL devices, spanning tree status is moved into Disabled state after upgrading into 8030n image Condition: In SXL device, enable spanning tree on to a VLAN and reload the device will move the access port going to disabled state. High Defect ID: DEFECT000636598 Technical Severity: Reason Code: Already Fixed in Release Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: Security Vulnerability Symptom: Client loses L3 connectivity when ARP inspection is enabled on a VLAN and Static ARP inspection entry is configured for the client's IP-address under non-default VRF. Condition: ARP inspection is enabled in VLAN. Static ARP inspection entry is configured for the client under non-default VRF. High Defect ID: DEFECT000636733 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.30 Technology: LAG - Link Aggregation Group Symptom: Ping not working if enabled route-only on interface level of deployed lag Condition: 1.Form the 10G lag Between Spatha1 & Spatha2 2.Configure ip address & Route-Only on primary interface 3.undeploy the lag & deploy it again 4.ping fails Critical Defect ID: DEFECT000637213 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.40 Technology: 802.1x Port-based Authentication Symptom: Switch reboots unexpectedly when MAC-authentication is attempted. Condition: 1. On a Flexible Authentication enabled port , if there is an existing Dot1x session for PC in Restricted Vlan. 2. VOIP phone attempts MAC-Authentication and Authentication is successful. High Defect ID: DEFECT000637795 Technical Severity: Reason Code: Will Not Fix Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Configuration Fundamentals Symptom: DHCP snooping database is not built. Condition: When DHCP snooping device is connected between DHCP Relay and DHCP Server, the DHCP snooping database is not built. High Defect ID: DEFECT000637967 Technical Severity: Reason Code: Not Reproducible Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: MAC Port-based Authentication Symptom: Switch might reload unexpectedlysometimes when a Mac-Auth client in Critical or Restricted vlan, is removed. Condition: Clear a Mac-Auth sessions in Critical or Restricted VLAN. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 45 High Defect ID: DEFECT000637983 Technical Severity: Reason Code: Already Fixed in Release Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.30 Technology: RMON - Remote Network Monitoring Symptom: SNMP monitoring reads some of the stack ports as "down" when they are up. MIB value .1.3.6.1.4.1.1991.1.1.3.31.2.2.1.8.2 might return value “3” (indicating port down) instead of value “2” (port up) when stack port is up and forwarding. Condition: 1) Configure snmp monitoring on the device by configuring snmp-server host ip address 2) Use SnmpGet or SnmpWalk from the snmp-server side with the OID .1.3.6.1.4.1.1991.1.1.3.31.2.2.1.8.2 High Defect ID: DEFECT000638127 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.30 Technology: Static Routing (IPv4) Symptom: Bringing down all the ports in the VLAN does not bring down the ve interface . This leads to loop and unnecessary traffic forwarding. Condition: On ICX devices data port is added as tagged/untagged to a VLAN and router-interface is added to it. With both in up state, physically remove the cable from the port. High Defect ID: DEFECT000638688 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: MAC Port-based Authentication Symptom: MAC-Authentication of client never succeeds if it fails once during re-authentication. Condition: MAC-Authentication and 802.1x are enabled on the interface. Initially MAC-authentication of client is successful with attribute indicating not to try 802.1x for the client. During re-authentication, if MAC-authentication fails, the client never successfully re-authenticates. Defect ID: DEFECT000639260 Reason Code: Not Reproducible Product: Brocade FastIron OS Reported In Release: FI 08.0.30 High Technical Severity: Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: ICX 7450-stack memeber is not reloaded when flash Image upgrade completed with BNA via TELNET and SCP Condition: 1. Discover device in BNA. 2. Select transfer options as Telnet-SCP. 3. Select 'save and reload' option. 4. Load flash image from BNA to primary of device. High Defect ID: DEFECT000639334 Technical Severity: Reason Code: Not Reproducible Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.60 Technology: 802.1x Port-based Authentication Symptom: 802.1x authentication is success for the supplicants connected to interface in member units of stack. When the clients re-authenticate, the re-authentication fails. Condition: 802.1x authentication is enabled on member port of stack. Period 802.1x re-authentication is also enabled. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 46 Critical Defect ID: DEFECT000640054 Technical Severity: Reason Code: Feature/Function Not Supported Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Configuration Fundamentals Symptom: Error traces might be observed randomly - "Error: remaining ticks (0) is smaller than elapsed ticks" Condition: Switch is up and running for 621 days. Workaround: Reboot before 621 days of system up time. If reboot was not done in 621 days and after that if errors are seen, then also reboot system. High Defect ID: DEFECT000641061 Technical Severity: Reason Code: Feature/Function Not Supported Probability: Medium Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.30 Technology: Hardware Monitoring Symptom: On ICX64xx unit if the diagnostic command "dm alt-diag" is run then the failure messages are seen on console Condition: This issue happens on ICX64xx unit when the diagnostic command "dm alt-diag" is run Medium Defect ID: DEFECT000642197 Technical Severity: Reason Code: Already Fixed in Release Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.30 Technology: Traditional Stacking Symptom: The stacked ICX7450 might get segmented, due to the stack ports bouncing back to IEEE mode from HiGig2 mode. Condition: This condition is observed only when the ICX 7450 units come up after a power cycle or reload to join the stack. Recovery: Manual power off/on Medium Defect ID: DEFECT000642495 Technical Severity: Reason Code: Will Not Fix Probability: Medium Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: PoE/PoE+ - Power over Ethernet Symptom: Poe Firmware not upgraded due to incompatible firmware and hardware Condition: ** This issue is NOT applicable for 8061 release and only applicable to 8030n release ** Medium Defect ID: DEFECT000642959 Technical Severity: Reason Code: Feature/Function Not Supported Probability: Medium Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: High Availability Symptom: The ICX6610 Stack Active unit goes for unexpected reload with FI 8.0.30 Image Condition: This issue happens on ICX6610 with FI 8.0.30 image. This defect is relevant for FI 8.0.30 release and it is not relevant for FI 8.0.61 release as this an unsupported platform FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 47 Medium Defect ID: DEFECT000644253 Technical Severity: Reason Code: Will Not Fix Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: Software Installation & Upgrade Symptom: On ICX7250 running FI 8.0.30n image if the image download is performed to secondary flash then sometime the following message is observed on console: skipping block 1a skipping block 1b Condition: This issue happens on ICX7250 switch running FI 8.0.30n build when the image download operation is performed FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 48 Known issues This section lists open software defects with Critical, High, and Medium Technical Severity as of 6-July-2017 in 08.0.61. Defect ID: DEFECT000633276 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: With full scale ACL configuration, active blocks the user from configuration changes for about 5 minutes during reload when standby is present. Condition: 1) Large ACLs (with 1000-1500 filters) should present in the configuration. 2) Standby is coming up. Defect ID: DEFECT000634546 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: MRP - Metro Ring Protocol Symptom: On a ICX7250 stack or the ICX7450 stack when the ports are removed and added to the VLAG then the MRP blocked ports re-converges, it moves from pre-forwarding to forwarding to blocking state Condition: This issue is seen on ICX7250 and ICX7450 stack when port is removed and added to the existing VLAG Defect ID: DEFECT000634778 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Management FI 08.0.60 Reported In Release: Technology: PoE/PoE+ - Power over Ethernet Symptom: Connected PDs in regular non fanless mode are not powered after a Reload Condition: Enabling fanless mode followed by a reload results in this issue - due to power allocation mechanism Workaround: The user can use the inline power power-limit or inline power power-by-class command for the port where a PD is connected and need an allocation within the available power Defect ID: DEFECT000636438 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.30 Technology: CDP - Cisco Discovery Protocol Symptom: CDP response from the device does not carry Voice Vlan even after requesting Voice VLAN from the other end. Condition: 1. Configure CDP and Voice VLAN on the Brocade device 2. Send CDP response. Defect ID: DEFECT000636974 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Traditional Stacking MAC Filters returned by Radius during Dot1x Authentication does not get applied on Stack Member Symptom: ports. Condition: User needs to configure MAC Filter on a dot1x port that is on a stack member FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 49 Defect ID: DEFECT000637116 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Stack Management Symptom: On a SPX (Switch port extender) setup involving ICX7750 at the core stack and ICX7250 as the port extenders, when the following steps are performed then an issue is seen where one of the port extender unit does not get MAC address assigned and the SPX port connected to that PE unit goes in Blocking state. Steps to see the problem: 1. Reload the SPX stack with traffic running across the system 2. Perform the stack Switch Over on core ICX7750 stack 3. After this we observe that one of the PE unit is missing the MAC address and the SPX port connected to that PE goes in blocking state Condition: This issue is seen on a SPX (Switch port extender) setup involving ICX7750 at the core stack and ICX7250 as the port extenders, when the following steps are performed: 1. Reload the SPX stack with traffic running across the system 2. Perform the stack Switch Over on core ICX7750 stack Defect ID: DEFECT000637932 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: 802.1x Port-based Authentication Symptom: ACLs do not get programmed for clients connected on stack member ports during flexible authentication Condition: Observed when strict security mode is disabled Defect ID: DEFECT000638551 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Probability: High Technology Group: IP Multicast Technology: IGMP - Internet Group Management Protocol Symptom: STP states are inconsistent Condition: When there is standby -> member -> standby transition without reload of that unit Workaround: There is no workaround. Recovery: Reload that unit Defect ID: DEFECT000639235 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: LAG - Link Aggregation Group Partner info fields are not filled with 0 in show lag command for up to a few minutes. Symptom: Condition: Put the lag into mis-cabling error and then disable the whole lag. Workaround: There is no work around. Recovery: Wait for a few minutes. There is no functional impact. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 50 Defect ID: DEFECT000639272 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Probability: High Technology Group: Management Technology: SNMP - Simple Network Management Protocol Symptom: Upgrading Flash Image with TFTP-TELNET from BNA is not Working Condition: 1. Discover device in BNA. 2. Select transfer options as Telnet-TFTP 3. Select 'save and reload' option. 4. Load flash image from BNA to primary of device. Defect ID: DEFECT000639914 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: IP Source Guard Symptom: Reload of standby results in few empty DHCP related TCAM rule entries. Condition: Seen after a reload of standby with scaled IPSG clients (>1000) on a port Defect ID: DEFECT000640693 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Layer 3 Routing/Network Layer Reported In Release: FI 08.0.61 Technology: ARP - Address Resolution Protocol Symptom: Error messages corresponding to ARP and MRP show up on console during a failover of ICX 7150 stack Condition: Failover of a ICX 7150 stack Defect ID: DEFECT000640894 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Probability: High Technology Group: IP Multicast Technology: IGMP - Internet Group Management Protocol Symptom: After boot up “multicast router-port ethernet x/y/z” is missing from the configuration. Condition: When device boots with "dual-mode" configuration under interface sub mode and "multicast routerport ethe x/y/z" configured under VLAN sub mode. Workaround: Once the device boots-up, reconfigure command "multicast router-port ethe x/y/z". Defect ID: DEFECT000641382 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.30 Symptom: Unexpected switch reload Condition: Condition not known. Probability: High Technology Group: Stacking Technology: Traditional Stacking Defect ID: DEFECT000641399 Technical Severity: High Probability: High Brocade FastIron OS Product: Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: Member unit reloads upon configuring a scaled ACL consisting of more than 250 filters on default VLAN containing almost all ports of the system. Condition: Configuring a scaled ACL consisting of more than 250 filters on default VLAN containing almost all ports of the system. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 51 Workaround: Create the ACL with fewer filters and apply it to the default VLAN. Thereafter, add additional filters to the ACL individually. Defect ID: DEFECT000641759 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Layer 2 Switching Reported In Release: FI 08.0.61 Technology: LAG - Link Aggregation Group Symptom: After an ISSU upgrade or standby reload followed by switchover, dual-mode configuration on some of the LAG Interfaces get removed. Condition: Observed when sFlow and Dual mode are configured in the system Defect ID: DEFECT000641947 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: sFlow Symptom: sFlow is enabled by default on newly added ports of LAG Interface Condition: Seen when sFlow is already configured on some of the existing LAG ports Workaround: Add all ports to the LAG Interface and then selectively enable sFlow on ports where it is needed Defect ID: DEFECT000642164 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring On the ICX7150 if LRM adapter is connected to it without the fiber cable connection on the LRM Symptom: adapter's line side then on the ICX7150 side the port LED remains Up Condition: This issue happens on the ICX7150 when the LRM adapter is connected to ICX7150 without fiber cable connected to LRM adapter Defect ID: DEFECT000642165 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring Symptom: When the ICX7150 with LRM adapter is connected to other device and the remote port is brought down then the ICX7150 port LED does not turn off Condition: This issue happens when ICX7150 using LRM adapter connects to remote port Defect ID: DEFECT000642234 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: SSH - Secure Shell Symptom: SCP command to copy running-configuration does not copy complete running-configuration. Condition: SCP command is used to copy running-configuration of ICX device. Defect ID: DEFECT000642244 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: IP Source Guard Symptom: Some Source guard entries bound on a port do not get applied as expected with traffic Condition: Issue is seen after a reload when the TCAM in Hardware is full FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 52 Defect ID: DEFECT000642580 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Monitoring Reported In Release: FI 08.0.61 Technology: Hardware Monitoring Symptom: This issue happens in the Switch port extender setup where ICX7450 is connected as a port extender. The LRM adapter is not supported on ICX7450. But if the user connects LRM adapter to ICX7450 working as a port extender and then the user issues "show media" CLI from control bridge then the LRM adapter is shown in the CLI output without information indicating that it is not supported Condition: This issue happens in the Switch port extender setup where ICX7450 is connected as a port extender and the LRM afapter is connected to the ICX7450 port Defect ID: DEFECT000643015 Technical Severity: Critical Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: PoE/PoE+ - Power over Ethernet Symptom: PoE Overdrive request from Ruckus R720 is not honored by ICX-7450 32ZP Condition: The power request from R720 is not matching the requirement. Also this feature is not supported on the ICX 7450-32ZP in 8061. Defect ID: DEFECT000643426 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: Error message indicating acl hardware resource error is seen and some filters do not get programmed Condition: When traffic policy ACL is already applied on the interface and ACL with accounting enabled is applied on interface. Recovery: Remove traffic policies. Remove and add filters which are not programmed properly. Defect ID: DEFECT000643836 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Traditional Stacking Symptom: On the ICX7450 stack setup where the 10 meter active QSFP cable is used for stacking link, sometime the stack port flap is observed where the stack port goes down and comes back up quickly. The issue is quite rare and seen only in some corner cases Condition: This issue is seen on ICX7450 stack where the 10 meter active QSFP cable is used for stacking over 40G stack ports. Defect ID: DEFECT000643853 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Traffic Management Reported In Release: FI 08.0.61 Technology: Rate Limiting and Shaping Symptom: Multicast port dampening on 3 unit stack, unit 3 as standby is not working after un-configuring and re-configuring Condition: In a ICX7150 stack, stack unit 3 or higher is configured as standby unit. Multicast port dampening configured on standby unit is un-configured and re-configured. Defect ID: DEFECT000644033 Technical Severity: Medium Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Symptom: CPU is around 12% to 16% Probability: High Technology Group: Layer 2 Switching Technology: xSTP - Spanning Tree Protocols FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 53 Condition: in scaled setup with 253 spanning tree instance Workaround: No workaround Recovery: No recovery Defect ID: DEFECT000644307 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: 802.1x Port-based Authentication Symptom: No LAG option for Webauth trust-port Condition: When configuring LAG interface as trust port, there is no option available Defect ID: DEFECT000644342 Technical Severity: Medium Probability: Medium Product: Brocade FastIron OS Technology Group: SDN Reported In Release: FI 08.0.40 Technology: OpenFlow Symptom: The openflow response from ICX device has mismatched port id when compared to the request. Condition: Openflow request is received by ICX to create port group. Defect ID: DEFECT000644361 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Stacking Reported In Release: FI 08.0.61 Technology: Stack Failover/Switchover Symptom: Stack reload needed for priority to take effect after multiple priority changes Condition: Observed with source guard configuration under vlan Workaround: Reload the stack for priority to take effect Defect ID: DEFECT000644390 Technical Severity: Medium Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: LLDP - Link Layer Discovery Protocol Symptom: LLDP Advertised Capabilities does not include 2.5G speed Condition: The device with link established for 2.5G ports Defect ID: DEFECT000644476 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: ACLs - Access Control Lists Symptom: When UDLD is enabled, LACP enabled LAG interface can flap if large ACL is applied/deleted on it. Condition: 1) UDLD must be enabled. 2) LAG should contain ports from stack member units. 3) ACL should contain more than 1000 filters. Workaround: If UDLD is disabled this issue will not be seen. Recovery: LAG interface will come back UP after the ACL programming is completed. Defect ID: DEFECT000644517 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: RADIUS Symptom: Connecting ICX device using RADIUS over TLS secure connection fails. Condition: Establish TLS secure connection using RADIUS. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 54 Defect ID: DEFECT000645489 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.30 Technology: 802.1x Port-based Authentication Symptom: Unable to enforce the Voice vlan to be tagged on the ICX interfaces. Condition: 1. Configure tagged voice VLAN. 2. PC and Phone connected to the ICX interface never acquires an IP address. Defect ID: DEFECT000645597 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Security Reported In Release: FI 08.0.61 Technology: IP Source Guard Symptom: A new filter added to an ACL which pertains to an IPSG entry which is earlier in the sequence order of IPSG entries bound does not get applied Condition: IPv4 Filter is added to an existing configured ACL after IPSG binding happens Workaround: Remove and reapply the ACL Defect ID: DEFECT000645640 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: SDN Reported In Release: FI 08.0.61 Technology: OpenFlow Symptom: When openflow L2 mode is enabled on a member unit port, ping to that port succeeds. Also ARP table is populated for the same. This causes the non openflow ports be able to send unicast traffic to the IP/MACs learnt (in ARP table) on openflow port. Condition: 1) Openflow is enabled on the member unit port. 2) IP address is configured on openflow interface. 3) ARP should be resolved before sending the traffic. Workaround: User can switch to L23 openflow mode as an alternative. Defect ID: DEFECT000645681 Technical Severity: High Probability: Medium Product: Brocade FastIron OS Technology Group: Stacking FI 08.0.61 Reported In Release: Technology: Mixed Stacking Symptom: SPX standby unit is continuously crashing after performing upgrade from 8040b to 8061. Condition: Perform upgrade test and try to apply TFTP copy of the config before the standby is ready. This is a timing issue. Workaround: Check standby is in standby ready before applying the TFTP config Recovery: reload will recover if crash is observed. Defect ID: DEFECT000646147 Technical Severity: High Probability: High Product: Brocade FastIron OS Technology Group: Management Reported In Release: FI 08.0.61 Technology: CLI - Command Line Interface Symptom: When there are lot of ICX devices acting as DHCP clients(100+) present in the same broadcast domain, when multiple clients started Discovery at the same time, CPU usage on some of the ICX devices goes to 99%. In addition, they will not be able to acquire an IP address. Condition: When there are lot of ICX devices acting as DHCP clients(100+) present in the same broadcast domain. Recovery: Reload of the ICX device that encountered the problem. FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 55 Defect ID: DEFECT000646386 Technical Severity: High Product: Brocade FastIron OS Reported In Release: FI 08.0.61 Probability: Medium Technology Group: Layer 3 Routing/Network Layer Technology: DHCP - Dynamic Host Configuration Protocol Symptom: ICX device running Layer-2 Switch image, and acting as DHCP client, will not re-acquire an IP address if it receives the NACK message from the DHCP server during RE_BIND process. Condition: The condition under which we observed this issue is following: 1. Multiple address pools configured on the DHCP server. 2. The interface through which the DHCP client is connected is moved to a different address pool, before the DHCP client tried the RE_BINDing the IP address. Workaround: Do not change the IP address pool in such a way that you move an IP address that got leased already. Recovery: Disable and followed by re-enable the DHCP client, at the global level. Syntax: Config# no ip dhcp-client enable Config# ip dhcp-client enable FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 56
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Charissa DeFrancesco Create Date : 2017:08:14 15:57:35-07:00 Modify Date : 2017:08:15 09:09:20-07:00 Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Charissa DeFrancesco Title : Release Notes Template (September 2015) Creator Tool : Microsoft® Word 2013 Metadata Date : 2017:08:15 09:09:20-07:00 Producer : Microsoft® Word 2013 Document ID : uuid:01538e94-9519-4358-b899-776122b00f9e Instance ID : uuid:2a9d8b03-f29a-4ab8-aba6-23c3cdfc94fa Page Count : 56EXIF Metadata provided by EXIF.tools