Ruckus Release Notes (September 2015) Fast Iron 08.0.61 08061 V2

FastIron 08.0.61 (GA) Release Notes FastIron_08061_ReleaseNotes_v2

2017-12-12

User Manual: Ruckus FastIron 08.0.61 Release Notes

Open the PDF directly: View PDF PDF.
Page Count: 56

14 August 2017
FastIron 08.0.61 for Brocade
Ruckus ICX Switches
Release Notes Version 2
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 2
Copyright © 2017 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, and MyBrocade are registered trademarks of Brocade Communications Systems, Inc., in the United States
and in other countries. Other brands, product names, or service names mentioned of Brocade Communications Systems, Inc. are listed at
www.brocade.com/en/legal/brocade-Legal-intellectual-property/brocade-legal-trademarks.html. Other marks may belong to third parties.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any
equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this
document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may
not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data
contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the
accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs
that accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other open
source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to
the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 3
Contents
Document history ....................................................................................................................................... 4
Preface ........................................................................................................................................................ 5
Contacting Brocade Technical Support ................................................................................................... 5
Brocade resources .................................................................................................................................. 5
Document feedback ................................................................................................................................ 6
Overview ..................................................................................................................................................... 7
New in this release...................................................................................................................................... 8
Hardware ................................................................................................................................................ 8
Software features ................................................................................................................................... 8
CLI changes ........................................................................................................................................... 10
RFCs and standards ................................................................................................................................... 12
Hardware support ..................................................................................................................................... 13
Supported devices ................................................................................................................................ 13
Supported power supplies .................................................................................................................... 13
Supported optics ................................................................................................................................... 13
Software upgrade and downgrade ........................................................................................................... 14
Image file names ................................................................................................................................... 14
PoE firmware files ................................................................................................................................. 14
Defects ...................................................................................................................................................... 15
Closed with code changes in release 08.0.61 ........................................................................................ 15
Closed without code changes ............................................................................................................... 42
Known issues ........................................................................................................................................ 49
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 4
Document history
Version
Summary of changes
Publication date
FastIron 08.0.61 for Brocade
ICX Switches Release Notes
Version 2
Added description of DHCP-
Based VE Provisioning
enhancement and made
editorial changes.
August 14, 2017
FastIron 08.0.61 for Brocade
ICX Switches Release Notes
Version 1
New enhancements and
features for the 08.0.61
release.
July 6, 2017
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 5
Preface
Contacting Brocade Technical Support
As a Brocade customer, you can contact Brocade Technical Support 24x7 online or by telephone.
Brocade OEM customers should contact their OEM/solution provider.
Brocade customers
For product support information and the latest information on contacting the Technical
Assistance Center, go to www.brocade.com and select Support.
If you have purchased Brocade product support directly from Brocade, use one of the following
methods to contact the Brocade Technical Assistance Center 24x7.
Online
Telephone
Preferred method of contact for non-urgent
issues:
Case management through the MyBrocade
portal.
Quick Access links to Knowledge Base,
Community, Document Library, Software
Downloads and Licensing tools.
Required for Sev 1-Critical and Sev 2-High issues:
Brocade OEM customers
If you have purchased Brocade product support from a Brocade OEM/solution provider, contact
your OEM/solution provider for all of your product support needs.
OEM/solution providers are trained and certified by Brocade to support Brocade® products.
Brocade provides backline support for issues that cannot be resolved by the OEM/solution
provider.
Brocade Supplemental Support augments your existing OEM support contract, providing
direct access to Brocade expertise. For more information, contact Brocade or your OEM.
For questions regarding service levels and response times, contact your OEM/solution
provider.
Brocade resources
Visit the Brocade website to locate related documentation for your product and additional
Brocade resources.
White papers, data sheets, and the most recent versions of Brocade software and hardware
manuals are available at www.brocade.com. Product documentation for all supported releases
is available to registered users at MyBrocade.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 6
Click the Support tab and select Document Library to access product documentation on
MyBrocade or www.brocade.com. You can locate documentation by product or by operating
system.
Release notes are bundled with software downloads on MyBrocade. Links to software
downloads are available on the MyBrocade landing page and in the Document Library.
Document feedback
Quality is our first concern at Brocade, and we have made every effort to ensure the accuracy
and completeness of this document. However, if you find an error or an omission, or you think
that a topic needs further development, we want to hear from you. You can provide feedback in
two ways:
Through the online feedback form in the HTML documents posted on www.brocade.com.
By sending your feedback to documentation@brocade.com.
Provide the publication title, part number, and as much detail as possible, including the topic
heading and page number if applicable, as well as your suggestions for improvement.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 7
Overview
Brocade FastIron Release 08.0.61 introduces the Ruckus ICX 7150 Z-Series switch, along with a
continued commitment to The Effortless Network vision of making the network flexible, easy
to manage, and cost-effective. The Effortless Network is enabled by Brocade® Campus Fabric,
which brings campus networks into the modern era to better support mobility, security, and
application agility. This evolutionary architecture integrates innovative technologies to
streamline application deployment, simplify network management, and reduce operating costs.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 8
New in this release
Hardware
The following section lists new hardware introduced with this release as well as hardware that is
not supported with this release.
New switch
Product name
Ruckus ICX 7150 Z-Series Switch
Description
Entry-level Stackable, 10G, and MultiGig Switch
Product features
The Ruckus ICX 7150 Z-Series switch offers the following features:
Full Layer 2 switching capability (4K VLANs, xSTP, Flexible
Authentication, RIP Advertisement, OpenFlow 1.0 & 1.3, Static
IPv4 routes)
Premium Layer 3 License (OSPF v2, OSPF v3, VRRP, VRRPv3,
VRRP-E, PIM-SM, PIMSSM, PIM-DM, PIM Passive)
16 2.5G+ Copper ports, that support 100M/1G/2.5G operation.
8 ports 1/10GE SFP+ Stacking/Uplink
Field Install Upgrade Licenses
Redundant Hot Swap Fans and Load-Sharing Power Supplies
New adapter
Product name
10G LRM Adapter
Description
10 GE LRM SFP+ Support on ICX 7150, ICX 7250 & ICX 7750
Software features
The following section lists new, modified, and deprecated software features for this release. For
information about which platforms support these features, refer to the FastIron Features and
Standards Support Matrix, available at www.brocade.com.
New software features for 08.0.61
The following software features are introduced in this release.
Support for Additional Features on the ICX 7150
o 2x10G and 4x10G Stacking
o Layer 3 IP Routing features (with software license) IPv4 and IPv6 dynamic routes, OSPF
v2 & v3, PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6), PBR, Virtual Route
Redundancy Protocol VRRP (IPv4), VRRP v3 (IPv6),
o OpenFlow v1.0 and v1.3
o Virtual Cable Testing (VCT)
DHCP-Based VE Provisioning When the ICX device boots up in factory default mode running
the Layer 3 router image, the default VE is created based on the DHCP server option (option 43)
and the DHCP IP address is assigned to the VE.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 9
LAG Virtual interface The requirement for a primary port that anchors the LAG is removed;
instead, all features running over a LAG will be anchored on the LAG virtual interface.
IP Source Guard (IPSG) at VLAN Level IP source guard can be enabled on an ICX device for a
range of ports in a VLAN or on the entire VLAN.
IPSG scale 520 clients per interface for stacking and 256 clients per interface for SPX. On
certain Brocade devices, such as ICX 7150 which have smaller TCAM, the IP source guard entries
are limited to 256 entries.
PVST+ protect If a PVST+ packet is received on a port configured for MSTP, an ICX device
floods it to all its ports in the VLAN so that it reaches other PVST+ devices across the VLAN. This
flooding can sometimes cause a port to be blocked on the Cisco side. This feature prevents this
flooding, blocking the PVST+ BPDU and marking the port as ERR-DISABLED.
MSTP Root Guard Root guard is supported for MSTP at the port level, to ensure that the port
is in the designated state all the time.
Protected Port Protected ports restrict Layer 2 communication among such ports at the
system level, providing isolation to end hosts.
Campus Fabric Enhancements
o SPX E-channel identifiers (E-CID) ping/trace The Switch Port Extender (SPX) ping
command has been added to assist in data port troubleshooting.
o ZTP enhancements Zero-touch and SPX interactive-setup have enhancements to
harden the discovery process as of FastIron release 08.0.61. Zero touch provisioning was
hardened to drop user traffic until the discovery of the new units is complete. To
enhance troubleshooting, new show commands are also introduced.
o EEE support on SPX In addition to standalone and stacking environment, Energy
Efficient Ethernet (EEE) is supported on SPX environment. When ICX7450 and ICX7250
platforms are used as a port extender (PE), the EEE feature can be configured from
Control Bridge (CB) unit.
DHCP static MAC address to IP address mapping Based on the client MAC-address you
can statically configure the IP address to the MAC address in the DHCP server. This configuration
is useful when you need to have selected clients assigned with particular IP addresses from the
server. Whenever a DHCP discover message is received from these clients, based on the static
configuration, the IP address will be assigned with the other required parameters.
DHCP options 43 and 60 ICX devices running as DHCP servers can be configured with Option
43 and Option 60. DHCP option 60 helps in identifying the incoming DHCP client. If the vendor
class ID advertised by the DHCP client matches with the DHCP server, the server makes a
decision to exchange the vendor-specific information configured as part of DHCP Option 43.
supportSave for SCP supportSave utility added for SCP.
PoE Overdrive PoE overdrive feature allows the Class 0 and Class 4 PoE-powered device to
negotiate for power greater than 30-watt allocation in 2-pair wire mode. The maximum power
that can be processed based on LLDP negotiation is limited to the hardware capability of the
power-sourcing equipment. This feature is supported only with ICX 7150-48ZP and Ruckus APs.
The supported AP is R720 with release 3.5.1 or later.
Flexible Authentication Enhancements
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 10
o Critical Voice VLAN Voice VLAN configuration facilitates the continued functioning of
Voice over IP (VoIP) phones when external server authentication or authorization fails.
o Reauthentication with dead RADIUS server To detect dead RADIUS servers, you can
configure regular monitoring that begins at system startup.
o Multiple IPv6 addresses with dynamic ACLs Up to four IPv6 addresses are supported
with dynamic ACLs.
o Additional RADIUS attributes Acct-Terminate-Cause, Class, Framed-IPv6-Address and
Idle-Timeout.
o Colon-separated MAC address format for MAC authentication
CLI changes
The following section lists new, modified, and deprecated commands for this release.
New commands in 08.0.61
The following commands are new in this release:
auth-timeout-action
authentication voice-vlan
clear pvst-plus-protect-statistics
enable nd hop-limit
errdisable recovery
ignore-temp-shutdown
inline power overdrive
interface lag
lacp-mode
lag-mac
mstp root-protect timeout
protected-port
pvstplus-protect
show hardware ipv6-route
show hardware route
show ip arp inspection
show license installed
show mstp root-protect
show protected-port
show pvstplus-protect
show spx csp
show spx debug
show spx zero-touch ipc
show spx zero-touch log
show spx zero-touch status
spx ping
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 11
system-max l3-interface
voice-vlan
Modified commands in 08.0.61
The following commands have been modified in this release:
auth-fail-action (flexible authentication)
clear access-list accounting
copy flash flash
default-ports
inline power install-firmware
inline power install-firmware scp
ip dhcp-client enable
ip rip prefix-list
ip route
ip rip route-map
ipv6 route
ipv6 route next-hop
ipv6 route next-hop-enable-default
ipv6 route next-hop-recursion
lag
license install perpetual
mac-authentication password-format
mka-cfg-group
multi-stack-port
multi-stack-trunk
poison-reverse
prefix-list (RIP)
pvst-mode
regenerate-seq-num
reload
ring interfaces
show access-list accounting
show acl-on-arp
show configuration
show dot1x sessions
show hardware mac entry
show inline power debug-info
show inline power emesg
show ip dhcp snooping info
show mac-authentication sessions
show running-config
show running-config interface ethernet
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 12
show span vlan
show stack
show statistics
show statistics dos-attack
show spx
show spx-mon
show version
show vlan
source-guard enable
tagged
Several commands have been updated to include Ethernet LAG ID options. Please refer to the Brocade
FastIron Command Reference.
Deprecated commands in 08.0.61
The following commands have been deprecated in this release:
chassis fanless-mode-enable (replaced by chassis fanless)
deploy
ip dhcp-client discovery-interval
ip dhcp-client continuous-mode max-duration
primary-port
show spx zero ipc (replaced by show spx zero-touch ipc)
static ethernet
tag-type
uplink-switch
RFCs and standards
The following RFCs and standards are newly supported in this release:
IEEE 802.3bz 2.5GBASE-T
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 13
Hardware support
Supported devices
The following devices are supported in this release:
Brocade Ruckus ICX 7150 Series (ICX 7150-C12P, ICX 7150-24, ICX 7150-24P, ICX 7150-48,
ICX 7150-48P, ICX 7150-48PF, ICX 7150-48ZP)
ICX 7250 Series (ICX 7250-24, ICX 7250-24G, ICX 7250-24P, ICX 7250-48, ICX 7250-48P)
ICX 7450 Series (ICX 7450-24, ICX 7450-24P, ICX 7450-32ZP, ICX 7450-48, ICX 7450-48F,
ICX 7450-48P)
ICX 7750 Series (ICX 7750-26Q, ICX 7750-48C, ICX 7750-48F)
Supported power supplies
For a list of supported power supplies, refer to the Data Sheet for your device. Data Sheets are
available online at www.brocade.com.
Supported optics
For a list of supported fiber-optic transceivers that are available from Brocade, refer to the latest
version of the Brocade Optics Family Data Sheet available online at www.brocade.com.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 14
Software upgrade and downgrade
Image file names
Download the following images from www.brocade.com.
Device
Boot image file name
Flash image file name
ICX 7150
mnz10110.bin
Router:SPR08061.bin
Switch:SPS08061.bin
ICX 7250
spz10110.bin
Router:SPR08061.bin
Switch:SPS08061.bin
ICX 7450
spz10110.bin
Router:SPR08061.bin
Switch:SPS08061.bin
ICX 7750
swz10110.bin
Router:SWR08061.bin
Switch:SWS08061.bin
PoE firmware files
The following tables lists the PoE firmware file types supported in all 08.0.61 releases. The
firmware files are specific to their devices and are not interchangeable. For example, you cannot
load ICX 7250 firmware on an ICX 7450 device.
Note: The PoE circuitry includes a microcontroller pre-programmed at the Brocade factory. The
software can be loaded as an external file. The initial release of the microcontroller code is still
current and does not need to be upgraded. The PoE firmware version string will be kept updated
to match the corresponding FastIron software version; however, this is only a cosmetic change,
and the firmware itself remains unchanged. If a new version of the code is released, Brocade will
notify its customers of the needed code upgrade. Finally, in the remote case that a failure occurs
during an upgrade process, the switch would still be functional but without PoE circuitry. If you
encounter such an issue, please contact Brocade Technical Support.
Table 1 PoE firmware files
Device
Firmware version
File name
ICX 7150
1.8.8 fw
Icx7xxx_poe_01.8.8b001.fw
ICX 7250
1.8.8 fw
Icx7xxx_poe_01.8.8b001.fw
ICX 7450
1.8.8 fw
Icx7xxx_poe_01.8.8b001.fw
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 15
Defects
Closed with code changes in release 08.0.61
This section lists software defects with Critical, High, and Medium Technical Severity closed with
a code change as of 6-July-2017 in 08.0.61.
Defect ID:
DEFECT000574969
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.40
Technology:
Traditional Stacking
Symptom:
If there are continuous traffic to L3 hosts connected on stack and ingress port is on standby or
member units, then every one minute there will be 1 or 2 packets drop(depends on traffic rate)
Condition:
1: There are continuous traffic to L3 hosts connected on Router stack.
2: Ingress port is on standby unit or member unit.
3: Traffic rate is around 5% or more.
Defect ID:
DEFECT000593233
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.60
Technology:
NTP - Network Time Protocol
Symptom:
NTP Clock when receives with wrong reference clock from the server (CVE-2016-1551)
NTP packet when received with origin timestamps, leads to NTP associations are demobilized (CVE-
2016-4953, CVE-2015-8139)
ICX device sometimes leads to crash, when crafted packet received with hmode > 7 in peer
association(CVE-2016-2518)
Spoofed crypto packet sometimes, demobilize the NTP client associations (CVE-2016-1547).
Condition:
Patch for vulnerability issues :
1. CVE-2016-1551
2. CVE-2016-4953, CVE-2015-8139
3. CVE-2016-2518
4. CVE-2016-1547
Recovery:
User can re-configure a new NTP server in ICX
Defect ID:
DEFECT000597195
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
RIP - IPv4 Routing Information Protocol
Symptom:
No, big impact to the customer. More control packets are trapped to the CPU even when the
associated VE Router interface is deleted or IP address is un-configured.
Condition:
None.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 16
Defect ID:
DEFECT000599682
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
Windows PC does not get 802.1x authenticated when FI device has auth-timeout action configured as
success and RADIUS tines-out. .
Condition:
802.1x is enabled on an interface connected to Windows PC supplicant and the auth-timeout action is
configured as success.
Defect ID:
DEFECT000607508
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
ACLs - Access Control Lists
Symptom:
ACL's are not effective for PE ports immediately after the system reload and also a specific PE
reload.
Condition:
1) Scaled IPv4 ACLs should present i.e. each ACL should have at least 900 filters or more.
2) Large ACL should be applied on port.
Workaround:
If configuration contains large ACL definitions and if they are not used remove them.
Recovery:
System auto recovers after certain time depending on the number of ACL rules configured. And the
maximum noticed time is about ~13 minutes.
Defect ID:
DEFECT000610871
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.50
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
Few entries are not getting updated in v6 snooping table but v6 sessions are bound.
Condition:
When there are 10 DHCP hosts and v6 snooping tables are not updated.
Defect ID:
DEFECT000612108
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.50
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
'show inline power emesg' displays only local unit events.
Condition:
Remote unit poe events cannot be displayed from Active Unit of stack system using 'show inline
power emesg'
Workaround:
Do a rconsole to remote unit or connect to remote unit console to get the poe events displayed for
that remote unit.
Recovery:
Defect ID:
DEFECT000613148
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.50
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
SNMPv3 traps are not generated after switchover or failover during ISSU.
Condition:
Upon switchover or failover during ISSU SNMPv3 traps are not seen.
Recovery:
There are 2 ways to recover from this issue:
1. Restart the SNMP trap receiver.
2. Disable checking "time window" for SNMPv3, if the trap receiver tool supports it.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 17
Defect ID:
DEFECT000616647
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
IP Source Guard
Symptom:
Removing a vlan using command 'no vlan <ID>' is leading to stale IPSG entries (IPSG entries on a
given vlan are removed when the VLAN is deleted).
Condition:
IP Source-guard is enabled on member ports of a VE port.
User VRF is enabled on the VE port.
VLAN (corresponding to the VE port) is deleted using 'no vlan <ID>'
Workaround:
Remove the VRF setting from VE
Remove the config on VE interface (no int ve)
Remove the vlan (no vlan <ID>)
Give a few seconds (around 20 seconds) time gap between executing two commands.
Defect ID:
DEFECT000617855
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.50
Technology:
Static Routing (IPv4)
Symptom:
When maximum (2K) IPv4 Static Routes are configured on a scaled SPX-System, High CPU might
be experienced for some period.
Condition:
When the customer reports High CPU/sluggish CLI on a SPX-System after creation of around 2K
static routes.
Defect ID:
DEFECT000619315
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Using 'no authentication' leaves a port in dynamic VLAN
Condition:
A Client is authenticated and port is dynamically added to a VLAN. Now if all Flexible
authentication are removed using 'no authentication', port is not removed from the Dynamic VLAN,
even though session for the client is removed.
Defect ID:
DEFECT000619420
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Users' counts is not not in sync after switch-over
Condition:
1)Bring up 1020 dot1x sessions on a PE port
2)Issue "show dot1x sess br"
3)Execute a switch-over and issue command from step 2 again on new Active
However, the output from step-3 is not in sync output from step-2
Workaround:
No workaround
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 18
Defect ID:
DEFECT000620652
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Users fail to authenticate when STP is enabled on dynamic VLAN
Condition:
User is trying to authenticate using dot1x and Radius server provides dynamic VLAN as part of
AAA-ACCEPT message.
If the Dynamic VLAN has STP enabled, then the User fails to authenticate
Workaround:
Works with RSTP and issue is seen only with STP (legacy)
Defect ID:
DEFECT000623517
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.50
Technology:
Mixed Stacking
Symptom:
Error message - "Invalid device number for ACL stacking buffer" seen along with stack trace
Condition:
Seen under certain conditions during a SPX Reload and DOS Attack configuration
Defect ID:
DEFECT000623569
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
MAC Port-based Authentication
Symptom:
A Webauth Client gets Authenticated without a RADIUS returned ACL attribute, and then a second
client gets authenticated with RADIUS returned ACL. At this time, first user's Session gets removed
and needs to be authenticated again.
Condition:
One or more users get authenticated without an ACL attribute in the radius profile followed by a user
with ACL attribute.
Recovery:
Authenticate the first user again
Defect ID:
DEFECT000624291
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.60
Technology:
Hardware Monitoring
Symptom:
On ICX7150 unit when the 1G access port is disabled and enabled then the adjacent next port drops
the traffic for a very short time duration around 20 milli-seconds. The traffic resumes after that short
time
Condition:
The issue happens on ICX7150 units 1G access port when it is disabled and enabled then the adjacent
next port encounters this issue
Defect ID:
DEFECT000624655
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.40
Technology:
CLI - Command Line Interface
Symptom:
Loss of text in the output of commands executed from telnet terminal.
Condition:
When the ICX is accessed via its telnet server and then its telnet client is used to connect to another
device, loss of text can be observed in the output of commands run on that other device.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 19
Defect ID:
DEFECT000626010
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
ACLs - Access Control Lists
Symptom:
ACL entries are missed upon reload with the error :
Error: ACL operation failed since filter id exceeds allowed maximum.Please try regenerate-seq-num.
Condition:
Running regenerate sequence number command with a gap value less than default which can result in
sequence numbers exceeding the maximum value if the gap value were to default. Here is an
example:
ACL_1:
sequence 10 permit x.x.x.x any
permit y.y.y.y any
permit z.z.z.z any
Regenerate sequence number:
regenerate-sequence-number 64995 1
ACL_1:
64995: permit x.x.x.x any
64996: permit y.y.y.y any
64997: permit z.z.z.z any
The above ACL_1 on reload will result in not adding filter number 2 and 3 since first filter starts with
sequence number 64995 and adding the default gap(10) results in sequence number 65005 which is
greater than the maximum allowed value.
Workaround:
When specifying the gap value smaller than default ensure the resultant sequence numbers would
still fit if the gap value were to be default value.
Defect ID:
DEFECT000626028
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Stack traces and error messages seen on Active and Standby Units
Condition:
While executing CLI command "no mac-auth enable all"
Workaround:
No workaround
Defect ID:
DEFECT000626459
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
MAC Port-based Authentication
Symptom:
Flexauth port stays in dynamic VLAN after disabling MAC authentication
Condition:
After successful mac-authentication is done, disable mac-authentication from the port
Workaround:
Reload the device to effect the change after doing a "wr mem"
Recovery:
Reload the device to effect the change after doing a "wr mem"
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 20
Defect ID:
DEFECT000626847
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Mixed Stacking
Symptom:
In the scaled campus fabric setup, sometime show command output for Flexible authentication feature
is not complete and have only partial
output . Also CLI response slowness is observed during the command execution.
Condition:
The partial command output and CLI response slowness is observed only with the scaled campus
fabric setup which has more than 4 control bridges and 30 port extender nodes.
Workaround:
Retry the flexible authentication show command when output is partial.
Defect ID:
DEFECT000627372
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.50
Technology:
VLAN - Virtual LAN
Symptom:
SPX PE port is assigned to dynamic VLAN even when it is not supposed to be assigned
Condition:
Observed when 'max-vlans' under port has reached the configured limit before authentication
Defect ID:
DEFECT000627486
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
RADIUS
Symptom:
Sometimes, even when a RADIUS server is available, the dead-RADIUS server logic may detect the
server unavailable and subsequent authentication requests could time out and the timeout action is
taken.
Condition:
None
Workaround:
Remove the RADIUS server and add it back again.
Defect ID:
DEFECT000627499
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.40
Technology:
Hardware Monitoring
Symptom:
On ICX7450 and ICX7250 running system when the USB drive is inserted then sometimes the USB
file system does not get mounted and the files are not accessible
Condition:
This issue happens on ICX7450 and ICX7250 when USB drive is inserted in a running system
Workaround:
After reload the USB drive is mounted correctly and files are visible after that
Recovery:
This works fine after switch reload
Defect ID:
DEFECT000628361
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.60
Technology:
MLD - Multicast Listener Discovery
Symptom:
Some of the well-known IPv6 multicast addresses like ff05::1:3 are being mld-snooped. It applies to
both dynamic as well as static entry creation.
Condition:
Customer may observe mld-snooping on some well-known IPv6 multicast addresses.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 21
Defect ID:
DEFECT000630003
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.60
Technology:
UDLD - Uni-Directional Link Detection
Symptom:
UDLD enabled ports moving to link disabled state with stack unit priority change followed by
switchover.
Condition:
If an older standby is selected as standby again (due to a priority change for the stacking member)
then the UDLD enabled ports go to Link disabled state after switchover.
Defect ID:
DEFECT000630173
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
ACLs - Access Control Lists
Symptom:
When MLD snooping is enabled with VLAN range command with continuous traffic through an ICX
device high CPU condition will happen.
Condition:
1) At least 100 VLANs with range command is configured with MLD snooping.
2) Per VLAN 18 multicast flows are present.
3) IPv6 ACL is present on the port
Recovery:
Unbind and bind the ACL on the port.
Defect ID:
DEFECT000630312
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
DHCP Client is wrongly configured with ip-address 0.0.0.0
Condition:
When management interface is Up, DHCP Client receives address 0.0.0.0. Works fine, when
management interface is disabled
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 22
Defect ID:
DEFECT000630434
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Traditional Stacking
Symptom:
status of some units in linear stack shows: Synchronizing (st=8)
Enter command "show stack", the stack info would shows like:
mailto:[STBY]local-3@ICX7150-C12 Router#show stack
T=1h16m59.7: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX7150-24 member 00e0.5200.0100 0 remote Synchronizing (st=8)
2 S ICX7150-48P member 748e.f882.e418 0 remote Synchronizing (st=8)
3 S ICX7150-C12P standby cc4e.2408.d465 0 local Ready
4 S ICX7150-24P active cc4e.24b4.729c 0 remote Ready
active standby
+---+ +---+ +---+ +---+
| 2 |3/3--3/1| 4 |3/3--3/1| 3 |3/2--3/1| 1 |
+---+ +---+ +---+ +---+
Condition:
1, linear stacking
2. the beginning/end unit of the stack has only one stacking port configured.
Workaround:
configure with both stacking ports in each unit. "write mem" and "reload" may be needed.
Recovery:
configure with both stacking ports in each unit. "write mem" and "reload" may be needed.
Defect ID:
DEFECT000630511
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
AAA for SSH login does not fail-over to local account when TACACS+ key mismatched between FI
and the tacacs server
Condition:
When FI device is configured with both local and TACACS+ authentication. TACACS+ key
mismatch happens.
Workaround:
NO
Defect ID:
DEFECT000630684
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
OSPF - IPv4 Open Shortest Path First
Symptom:
OSPF Router LSAs are present in incorrect areas, where the links don't exist.
Condition:
Router LSA for an interface configured under Area 1.
Defect ID:
DEFECT000630960
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
DoS (Denial of Service) protection
Symptom:
Traffic leak might be observed on ICX7x devices, if an interface port security is enabled with age 0.
Condition:
On FI 7X platforms,
1. Enable Port security on an interface with age 0
2. Configure Secured macs
3. Tag multiple ports to same vlan.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 23
Defect ID:
DEFECT000631080
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Mixed Stacking
Symptom:
On ICX7250 when the switch is upgraded from 8.0.50 or earlier release to 8.0.60 release image then
in some of the cases the existing POD license file gets deleted. This is a very corner case and happens
only in some units
Condition:
This happens on ICX7250 switch when it is upgraded from 8.0.50 or earlier release to 8.0.60 release
image then this issue is observed in some units
Defect ID:
DEFECT000631474
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Unexpected reset seen on active unit of a stack during a reload of PE
Condition:
PE Reload
Defect ID:
DEFECT000631665
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Stack Failover/Switchover
Symptom:
Residual entries in Member unit TCAM which could potentially impact traffic through this unit
Condition:
Observed after an ISSU upgrade to a newer image
Defect ID:
DEFECT000632033
Technical Severity:
Low
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Port Mirroring
Symptom:
Even if the size limit in "debug packet-capture mode pcap-fmt <limit>" is greater than 60 bytes,
captures of outgoing packets are still limited to 60 bytes.
Condition:
When "debug packet-capture mode pcap-fmt <limit>" is limit to 60 bytes.
Defect ID:
DEFECT000632408
Technical Severity:
Low
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.40
Technology:
Port Mirroring
Symptom:
The output of "debug packet-capture mode pcap-fmt" is corrupted. Specifically, a timestamp appears
before every single packet byte.
Condition:
In debug packet mode, select pacap-fmt mode and set limit for it (1-65535). Then while we capturing
packets, we can see every byte is getting timestamp in output.
Defect ID:
DEFECT000632465
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
OSPF - IPv4 Open Shortest Path First
Symptom:
OSPF intra-routes are not installed in IP routing table when intra-area routes and area range
configuration in the ospf area are for same IP Prefix.
Condition:
IP Unicast traffic loss as IP route points to drop next-hop
Workaround:
Remove & add the area range configuration.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 24
Defect ID:
DEFECT000632718
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
An unauthenticated entry is created along with an authenticated entry for same mac-auth user
Condition:
When the user tries to do mac-authetication
Defect ID:
DEFECT000632719
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Residual Filter entry in TCAM corresponding to a mac-authenticated user
Condition:
After clearing the session for user who is authenticated using mac-authentication. This is observed in
scaled setup.
Defect ID:
DEFECT000632720
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
MAC Port-based Authentication
Symptom:
Radius server Timeout is observed
Condition:
When user is trying to do authentication using mac-auth
Defect ID:
DEFECT000632888
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.60
Technology:
Software Installation & Upgrade
Symptom:
Boot Configuration - "boot system flash secondary" config is not synced to standby unit
Condition:
The issue is seen upon a ISSU upgrade, when a ISSU Secondary is executed
Workaround:
Manually configure "boot system flash secondary" in the secondary
Defect ID:
DEFECT000633181
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
IP Source Guard
Symptom:
IPSG residual entries remain in tables after removing the VLAN of which the LAG interface is a
member
Condition:
Seen in Switch image.
IPSG is enabled on primary port of a LAG and the ports are part of a vlan. DHCP snooping/IPSG
entries are learnt on the primary port of LAG.
Vlan is removed
Workaround:
Clear the IPSG entries or unconfigure IPSG config on the primary port, before removing the vlan
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 25
Defect ID:
DEFECT000633185
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IGMP - Internet Group Management
Protocol
Symptom:
ICX7xxx would sometime reset upon doing a switchover.
Condition:
- ICX7xxx product running switch image
- Switchover and failover operation on stack
- IGMP configured on the vlan
Workaround:
no work around available
Recovery:
no recovery plan available.
Defect ID:
DEFECT000633402
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
Authorization and accounting fail-over to the next method fails, when authenticated via fail-over
action in key mismatching scenario between server and device.
Condition:
SSH authorization and accounting fails with key mismatch.
Defect ID:
DEFECT000633563
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
QnQ - IEEE 802.1Q
Symptom:
When VLAN bridging is configured, the unicast pacekts destined to the management VLAN via non-
management VLAN port is dropped.
Condition:
When loopback cable is connected between management VLAN and non-management VLAN, the
unicast packets destined to the management VLAN via non-management VLAN port is dropped.
Defect ID:
DEFECT000634055
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Mixed Stacking
Symptom:
In the scaled campus fabric topology, some times ACL rules are missing in some of the port extenders
after repeated reload of entire stack.
Condition:
ACL rules are missing in some of the port extenders with repeated entire stack reload is observed
only with the scaled campus fabric topology which has more than 4 control bridges and 36 port
extender nodes.
Defect ID:
DEFECT000634334
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
LACP flap might be observed when range of interface is disabled.
Condition:
1. Configure lacp-timeout-short.
2. Configure MCT.
3. Disable a range of 48 interfaces.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 26
Defect ID:
DEFECT000634343
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Mixed Stacking
Symptom:
in SPX chain when one ICX7450-32ZP Port Extender switch using 2.5G port connects to another
ICX7450 port extender switch using its 1G port then the port extender switch does not join the SPX
setup.
Condition:
This issue happens when ICX7450-32ZP 2.5G port is connected to ICX7450 1G port in the SPX
chain
Defect ID:
DEFECT000634354
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.60
Technology:
Hardware Monitoring
Symptom:
In the ICX7250 switch when the 10G SFP+ optics is inserted to module 2 ports then sometime the
error message is seen on output.
Condition:
The issue is seen when 10G SFP+ is inserted in ICX7250 switch module 2 ports at run time.
Defect ID:
DEFECT000634418
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
On Fast Iron platforms, Directed broadcast/WOL packets might not work when using VRF
Condition:
On ICX devices, when VRF is part of two VEs, then with intervlan routing WOL/directed broadcast
packets will not be received.
Defect ID:
DEFECT000634552
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Mixed Stacking
Symptom:
After failover, PE can not attach to CB.
Condition:
PE attached to failover unit can not re-attach after switchover and Failover.
Recovery:
Reload whole SPX
Defect ID:
DEFECT000634632
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
xSTP - Spanning Tree Protocols
Symptom:
MSTP BPDU's might not be forwarded after enabling loop-detection in the default VLAN.
Condition:
1.Configure the port connected to third party vendor switch as dual-mode port and enable MSTP.
2. Disable MSTP on the ICX7250 Brocade switch.
3. Enable loop-detection in default VLAN of ICX7250 .
4. MSTP BPDU packets might be dropped.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 27
Defect ID:
DEFECT000634706
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Mixed Stacking
Symptom:
In SPX setup PE detaches every 40 minutes and connects back when ACL logging is configured on
PE interfaces with continuous logging traffic.
Condition:
1) ACL logging is enabled on PE interface(s) with active ACL binding.
2) Traffic matching the logging criteria is continuous and at least 5000 packets/sec.
Workaround:
1) Disable ACL logging when not in use.
2) Limit/apply rate limiting for the logging traffic below 4k packets/sec to make room to the
LLDP keep alive packets and other control packets which can compete with logging packets.
Defect ID:
DEFECT000634739
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
xSTP - Spanning Tree Protocols
Symptom:
Seeing error state "vlan_set_l2intf_stp_state(vlan_idx=1,pport=1/1/1,state=UNKNOWN,T=1097)
stg_id=5, get GALNET_STP_DISABLED & ERROR STATE" on STBY unit after
Condition:
downgrade from 8060 to 8030m
Workaround:
No workaround
Recovery:
No functional issue if no switchover is triggered after downgrade.
Defect ID:
DEFECT000634937
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.40
Technology:
OpenFlow
Symptom:
When greater than 100 Openflow flows in the system, if controller deletes flows beyond the 100,
there is a TCAM leak.
Condition:
1) Total flow count should be >100
2) Delete the flows beyond the first 100.
Recovery:
Use "clear openflow all" command to cleanup the stale TCAM entries.
Defect ID:
DEFECT000635080
Technical Severity:
Critical
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
CLI - Command Line Interface
Symptom:
ICX may unexpectedly reload, when CLI command with more than 256 characters is executed on the
terminal [Console or TELNET or SSH]
Condition:
When executing CLI command with more than 256 characters in a Console or TELNET or SSH
session.
Workaround:
Avoid CLI commands of size 256 characters or above.
Defect ID:
DEFECT000635492
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.50
Technology:
LAG - Link Aggregation Group
Symptom:
ICX7450 goes for unexpected reload.
Condition:
In ICX7450, when a port is configured as dual-mode and connected to the Aerohive AP, the switch
goes for reload in every few minutes.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 28
Defect ID:
DEFECT000635671
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
MCT - Multi-Chassis Trunking
Symptom:
In ICX7750-26Q unit when the 40G Breakout command is configured then some of the port's MAC
address assigned is same as the others
Condition:
The issue happens on ICX7750-26Q unit when the Breakout is configured through command line
Defect ID:
DEFECT000635709
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Stack Management
Symptom:
The system resets with a stack trace showing rel_ipc_receive_msg_callback()
Condition:
When the reliable IPC receives a reset signal (TCP reset), a pointer may be set to NULL before
accessing it. This causes crash. The reliable receives reset only when it tries to reconnect a broken
session.
Workaround:
There is no workaround. When this happens, the unit reloads.
Recovery:
The unit reloads.
Defect ID:
DEFECT000635787
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Traditional Stacking
Symptom:
The ICX 7150 may becomes a member when downgrading to 8.0.60 from 8.0.61. However, release
8.0.60 does not support ICX7150 stacking. Therefore, it gets stuck, and cannot be converted back to
standalone mode.
Condition:
The described problem happens when downgrading to 8.0.60. The fix in 8.0.61 is to prevent future
release downgrade to 8.0.61. The bug can only be fixed in 8.0.60 patch. It cannot be fixed in 8.0.61.
Workaround:
There is no workaround. Most stacking CLIs are blocked for ICX7150 in 8.0.60. The ICX7150
must run 8.0.61, do "stack unconfigure me" and become a standalone. Then, it can run 8.0.60.
Recovery:
Must reload the unit using 8.0.61 image. Then, when it boots up as a member, type "stack unconfigure
me" to remove the stacking related flash. It becomes a standalone. Then it can reload with 8.0.60
image.
Defect ID:
DEFECT000635966
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.40
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Unexpected reload when installing an unsupported PoE firmware file.
Condition:
PoE Firmware download
Defect ID:
DEFECT000636212
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Stack Management
Symptom:
The system resets with a stack trace showing rel_ipc_receive_msg_callback()
Condition:
When the reliable IPC receives a reset message from its peer, it sets a pointer NULL before accessing
it. This causes the unit to reload. The reliable IPC rarely receives reset signal. It happens only when
reliable IPC tries to reconnect a broken session due to some error.
Workaround:
No workaround is available. The unit reloads.
Recovery:
The units reloads.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 29
Defect ID:
DEFECT000636385
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IPv4 Multicast Routing
Symptom:
L3 IP Multicast forwarding entries (routes) are not getting programmed causing traffic drop.
Condition:
Applicable to all ICX7xxx products, when ospf flaps on a PIM Router where the route to source/RP
are same. This issue is seen when the LHR is loosing the route to source and relearning the route
again. The upstream router to RP and source is same. In such a scenario the LHR generates (s,g) join
(*,g) join with (s,g, rpt) prune and also (s,g) prune which is incorrect. In working condition the LHR
should never generate the (s,g) prune when the route is learnt.
Workaround:
no workaroud
Recovery:
clear ip pim mcache on both router
Defect ID:
DEFECT000636592
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.61
Technology:
Rate Limiting and Shaping
Symptom:
BUM syslog notification is not generated when configured BUM rate-limit is higher than BUM
packet receiving rate on the port.
Condition:
BUM syslog notification feature is enabled on the interface. BUM traffic is received at higher rate
than configured rate-limit.
Defect ID:
DEFECT000636620
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IPv6 Multicast Routing
Symptom:
Rarely when L3 multicast flow getting learnt system will reset.
Condition:
Applicable to all ICX7xxx products, with L3 Multicast configuration and continuous traffic. Problem
is seen during system reload.
Workaround:
No workaround
Recovery:
No workaround
Defect ID:
DEFECT000636643
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
MCT - Multi-Chassis Trunking
Symptom:
In MCT setup if a port is configured as MCT client first and then LACP is configured on the port ,the
client Lag port will be shown as Err/Blocked.
Condition:
MCT Cluster with a LACP Client .
Recovery:
On MCT cluster device configure client port as part of LACP first and then configure the same as
MCT client .
Defect ID:
DEFECT000636714
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
Authentication fails when users connect on a port that is enabled after disabling
Condition:
Disabling the port and re-enabling the port results in this issue.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 30
Defect ID:
DEFECT000636715
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
802.1x Port-based Authentication
Symptom:
In stacking or SPX system, MAC movement across ports on remote unit is not working
Condition:
An Authenticated User moving across Ports on a remote unit
Defect ID:
DEFECT000636754
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
ERROR!!! rstp_port_class is NULL, this_stp=0, on console
Condition:
When enable or disable stacking
Workaround:
There is no work around
Recovery:
Reload the system
Defect ID:
DEFECT000636776
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
HTTP/HTTPS
Symptom:
Certificate generation with private key file of size 4096 bits is unsuccessful with error "Cert import
failed....Could not parse the PEM-encoded import data".
Condition:
Attempt to generate certificate with size 4096 bits key.
Defect ID:
DEFECT000636821
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
xSTP - Spanning Tree Protocols
Symptom:
Though the MAC authentication gets succeeded, MAC learning will not happen on auth-default-vlan.
Condition:
1. Enable both MSTP and MAC Authentication on an edge port
2. MAC authentication Succeeds.
Defect ID:
DEFECT000636903
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
CLI - Command Line Interface
Symptom:
ICX unexpectedly reloads when authenticating [Console/Telnet/SSH] user credentials with Radius
server.
Condition:
ICX unexpectedly reloads when AAA method is set to Radius and user authentication is done using
Radius server.
Defect ID:
DEFECT000637202
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.40
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
Device might reload unexpectedly during snmpwalk/snmpbulkwalk.
Condition:
1.Load an image without .bin extension in image name
2.Configure snmp-server community strings and enable the snmp-server
3.Perform ISO snmpwalk/snmpbulkwalk on brcdSPXOperUnitBuildlVer / brcdSPXOperUnitImgVer
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 31
Defect ID:
DEFECT000637334
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
Port State in "show interface" is wrong
Condition:
The port is untagged, enable spanning tree on a VLAN which is the port's default VLAN.
Workaround:
There is no work around.
Recovery:
There is no recovery, no functional impact also.
Defect ID:
DEFECT000637356
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
Openflow flows gets missed in hardware after controller connection is lost and re-established.
Condition:
1) There should be an active connection with controller.
2) And the connection to the controller is flapped
Defect ID:
DEFECT000637461
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
MAC Port-based Authentication
Symptom:
Unexpected reload of Active Unit of an ICX stack with authentication enabled
Condition:
This is observed when Radius server is not configured but mac-authentication is enabled. And then
User is attempting a mac-authentication.
Defect ID:
DEFECT000637602
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.60
Technology:
High Availability
Symptom:
The ICX device reloads unexpectedly.
Condition:
The ICX devices are connected in stack. Packet received in non-member unit of the stack that need to
be forwarded to the active unit.
Defect ID:
DEFECT000637960
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.61
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
DHCP snooping entries learnt on the switch are lost after reloading the ICX stack followed by switch-
over.
Condition:
DHCP snoop entries are learnt by ICX stack. ICX stack is reloaded and some unit(s) are not ready by
the time standby election happens. This is followed by a switch-over and the DHCP snoop entries
learnt by the stack are lost on New Active unit.
Defect ID:
DEFECT000637965
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IPv6 Multicast Routing
Symptom:
Assertion message on the login session appears when a IPV6 address on Layer 3 router interface is
configured with the interface value greater than 1026.
Condition:
On ICX7150 devices configuring an IPV6 address on a Layer 3 router interface whose interface value
is greater than 1026 can result in assertion message.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 32
Defect ID:
DEFECT000638000
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.40
Technology:
RMON - Remote Network Monitoring
Symptom:
In SNMP table, the value of snChasFan2OperStatus (OID 1.3.6.1.4.1.1991.1.1.1.3.2.1.4.2.1) returns
the wrong value for standby or member units in a stacking system.
The value returns other(1) if the fan status is normal for standby or member units in a stacking
system. The correct return value in this case should be normal(2)
Condition:
It happens always
Workaround:
User can use CLI command “show chassis” to display the fan status for all unit s in a stacking
system
Recovery:
none
Defect ID:
DEFECT000638069
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.50
Technology:
RAS - Reliability, Availability, and
Serviceability
Symptom:
ICX7450 or ICX7250 crashes while running 8040/8050/8060 image.
Condition:
The CPU sample feature is trying to decode the call trace, which is causing the crash to occur when it
is trying to decode the stack trace
Workaround:
Disable the Auto CPU Sample feature by executing the following commands in each of the unit
console:
dm cpu sample auto off
Recovery:
Disable the Auto CPU Sample feature by executing the following commands in each of the unit
console:
dm cpu sample auto off
Defect ID:
DEFECT000638087
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
In FastIron products, dynamic gateway obtained from DHCP is stored wrongly in startup config.
Condition:
In Fastiron products, obtain the dynamic gateway via DHCP server and do "write memory" will lead
to writing a wrong gateway in startup configuration file.
Defect ID:
DEFECT000638331
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.60
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
The ICX device reloads unexpectedly.
Condition:
When upgrading the code on DHCP-Server enabled ICX device, the device reloads unexpectedly.
Defect ID:
DEFECT000638365
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
Management GUI
Symptom:
Interface ports are down when LRM adaptor is plugged in ICX device and accessed using
HTTP/HTTPS. Port down syslog message are observed.
Condition:
Connect ICX via HTTP/HTTPS and modify the LRM interface speed in ethernet interface page.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 33
Defect ID:
DEFECT000638439
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
The UP link might get bounced, creating a temporary loss of connectivity to the switch.
Condition:
The condition is observed only when all the data ports on the device are disabled at once.
Defect ID:
DEFECT000638482
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
DHCP Client is not getting IP address from the Server.
Condition:
When the DHCP client sends DHCP Discover with option 50 (requesting for a particular IP) and if
that IP address is excluded in the pool, the client is not getting IP assigned.
Defect ID:
DEFECT000638508
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Issue will be observed on the ports of a new unit that joins the stack and in dynamic mode .
Condition:
STP port priority is not set to default value for ports of newly joined unit .
Workaround:
After a unit joins the stack do a reload before changing the configuration on the ports of newly
joined unit in the stack .
Recovery:
change the stp port priority to default using the CLI :
spanning-tree Ethernet <stacked/slot/port> priority 128
Defect ID:
DEFECT000638525
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Stack Management
Symptom:
The ICX-7450 Running-config Update failure on stacked environment from USB disk.
Condition:
The condition is seen only when Running-config copied from USB stick for stacked environment. But
Works fine for Single Unit.
Defect ID:
DEFECT000638699
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
Active unit crashes while detaching large ACL from VE that has PE ports with ACL accounting and
logging enabled
Condition:
1) ACL should be large ie with more than 1000 filters.
2) ACL accounting is enabled on all/most filters.
3) ACL logging is enabled on all/most filters.
4) ACL logging traffic should present.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 34
Defect ID:
DEFECT000638737
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
LAG - Link Aggregation Group
Symptom:
DEFECT DOES NOT EXISTIt IN PREVIOUS VERSIONS OF SOFTWARE
Condition:
DEFECT DOES NOT EXISTIt IN PREVIOUS VERSIONS OF SOFTWARE
Defect ID:
DEFECT000638743
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
LAG - Link Aggregation Group
Symptom:
DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE
Condition:
DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE
Defect ID:
DEFECT000638751
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
LAG - Link Aggregation Group
Symptom:
DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE
Condition:
DEFECT DOES NOT EXIST IN PREVIOUS VERSION OF SOFTWARE
Defect ID:
DEFECT000638774
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
On the ICX7150 platform 1Gig copper ports if the port speed downshift is configured at 10Mbps
speed then if VCT (Virtual cable testing) command is run then the port goes down and then comes up
in 1Gbps speed despite downshift configuration being there
Condition:
On the ICX7150 platform 1Gig copper ports if the port speed downshift is configured at 10Mbps
speed then if VCT (Virtual cable testing) command is run then the port goes down and then comes up
in 1Gbps speed despite downshift configuration being there
Workaround:
This issue happens on the ICX7150 platform 1Gig copper ports if the port speed downshift is
configured and then if VCT (Virtual cable testing) command is run
Defect ID:
DEFECT000638967
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.60
Technology:
OpenFlow
Symptom:
Openflow flow that is received with priority greater than 32768 does not work.
Condition:
1. Openflow feature is enabled on the interface.
2. Openflow flows with priority greater than 32768 is received.
Defect ID:
DEFECT000639200
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
The fan speed change trap messages are still seen in trap receiver when trap is disabled
Condition:
1.Disable the fan speed change trap
2. View the fan speed change trap messages in trap receiver
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 35
Defect ID:
DEFECT000639224
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
IP Source Guard
Symptom:
With the IPSG enabled configuration, standby crashes on bootup
Condition:
1) IPSG is enabled on stack units
Defect ID:
DEFECT000639432
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
UDLD - Uni-Directional Link Detection
Symptom:
LAG ports are getting flap during the SNMPWALK of the MAUMIB
Condition:
1).Configure the LAG
2).Enable the UDLD
3).Perform the parallel SNMPWALK of the 'ifMauAutoNegTable', 'ifMauTable'
4).Lag ports getting flapped with following SYSLOG messages.
SYSLOG: <14> Jun 1 06:08:15 Port 1/1/29 : MODULE-UDLD : PORT-DOWN (Reason : Rem-
Seq Unchanged Exceed Max-Limit)
SYSLOG: <14> Jun 1 06:08:15 Port 1/1/29 : MODULE-UDLD : PORT-DOWN (Reason : No
Receive Exceed Max-ReTry)
SYSLOG: <14> Jun 1 06:08:15 System: Interface ethernet 1/1/29, state down
SYSLOG: <14> Jun 1 06:08:15 System: Logical link on interface ethernet 1/1/29 is down.
Defect ID:
DEFECT000639436
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.30
Technology:
PIM - Protocol-Independent Multicast
Symptom:
L3 IP Multicast traffic drop.
Condition:
Applicable on all ICX7xxx products, with PIM configured and IP Multicast traffic. Seen in a specific
topology viz.
active-receiver----ve17-Router1-ve9---- Router2
Router3--ve7--Router2 (RP)--ve7--Router4--ve7---- source (same vlan domain)
Workaround:
configure large prune-wait interval.
Recovery:
Configure large prune-wait interval
Defect ID:
DEFECT000639439
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.61
Technology:
IP Addressing
Symptom:
ISSU will abort due to protocol sync not complete as seen in show issu status.
Condition:
Applicable to all ICX7xxx products, during ISSU configuration. This problem is seen occasionally.
Workaround:
NO workaround
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 36
Defect ID:
DEFECT000639636
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.60
Technology:
NTP - Network Time Protocol
Symptom:
Unexpected reload of the device when NTP is enabled.
Condition:
NTP is enabled. NTP loses synchronization with all configured NTP servers.
Defect ID:
DEFECT000639786
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
SSH - Secure Shell
Symptom:
ICX may unexpectedly reload, when SSH session gets terminated with SSH key exchange in
progress.
Condition:
Disconnecting SSH session, while supportsave with scp is in progress or initiating SSH session from
secureCRT terminal and disconnect immediately.
Defect ID:
DEFECT000639822
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
ICX device sends accounting interim packet with service-type attribute as Call-Check instead of
Framed-user.
Condition:
802.1x authentication and interim-accounting are enabled on interface. The device sends interim-
accounting to the RADIUS server.
Defect ID:
DEFECT000640587
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.40
Technology:
RAS - Reliability, Availability, and
Serviceability
Symptom:
ICX7450 or ICX7250 crashes while running 8040/8050/8060 image.
Condition:
The CPU sample feature is trying to decode the call trace, which is causing the crash to occur when it
is trying to decode the stack trace
Workaround:
Disable the Auto CPU Sample feature by executing the following commands in each of the unit
console:
dm cpu sample auto off
Recovery:
Disable the Auto CPU Sample feature by executing the following commands in each of the unit
console:
dm cpu sample auto off
Defect ID:
DEFECT000640719
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
CLI - Command Line Interface
Symptom:
Static gateway configuration is lost from the running configuration.
Condition:
Overwriting dynamic gateway with same static gateway, followed by static IP address configuration
in the device.
Workaround:
Remove dynamic ip address before configuring the static gateway or configure the static ip
address before configuring static gateway.
Recovery:
Reconfigure the static gateway to recover the loss of static gateway
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 37
Defect ID:
DEFECT000640964
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
Re-authentication triggered by restricted Client is not working
Condition:
User is already in restricted vlan. Then if User triggers dot1x re-authentication request, it is getting
ignored by ICX
Defect ID:
DEFECT000641072
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Traditional Stacking
Symptom:
On ICX7250 stack environment with EEE (energy efficient ethernet) configured, when the standby
unit is reloaded then the CPU utilization goes high to 99% and console access is stuck for some time
Condition:
This issue happens on ICX7250 stack environment with EEE (energy efficient ethernet) configured
and standby unit is reloaded
Defect ID:
DEFECT000641307
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
Hardware STP state and Software STP state is out of sync.
Condition:
When unconfig the topology group's master VLAN.
Workaround:
There is no work around.
Recovery:
Reset the system.
Defect ID:
DEFECT000641415
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.60
Technology:
Hardware Monitoring
Symptom:
On ICX7250 switch when the external USB device is inserted to the switch then some times the
device is not detected. The USB device gets detected and and mounted after the unit reload.
Condition:
This issue happens only sometimes on the ICX7250 when external USB device is inserted to the up
and running system
Workaround:
The attached USB device gets detected and mounted after a reload is performed to the ICX7250
unit
Defect ID:
DEFECT000641644
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
CLI - Command Line Interface
Symptom:
In the ICX7150 stacking environment, if number of power supplies is equal to one then PoE
capability(PoE/Regualr) is not displayed under PSU details info of member unit
Condition:
This issue happens on ICX7150 stacking environment if the number of power supplies is equal to one
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 38
Defect ID:
DEFECT000641931
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
MCT - Multi-Chassis Trunking
Symptom:
In MCT cluster when a MCT peer reboots then joins back, we might see multicast traffic loss for up
to 125sec (for default query interval time) on some receivers connected to a MCT client until the next
IGMP/MLD query is sent.
Condition:
- v4/v6 Multicast snooping is configured on vlan
- Multicast source and receivers (IGMP/MLD) are on different MCT clients.
- In MCT cluster when a MCT peer reboots and then joins back (or CCP Up event)
Workaround:
By configuring the IGMP/MLD query interval to the smaller value, we can limit the traffic loss
only to that interval time
Recovery:
The problem will recover automatically once the next query is sent out. To speed up the recovery, try
configuring the IGMP/MLD query interval to the smaller value
Defect ID:
DEFECT000641986
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
sFlow
Symptom:
SFLOW collector reports length mismatch error.
Condition:
SFLOW version 5 is enabled. The SFLOW packet contains default-gateway information.
Defect ID:
DEFECT000642325
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
Even after disabling the fan traps, they are observed in the trap receiver.
Condition:
1.Disable fan-speed-change trap and fan-failure trap using,
no snmp-server enable traps fan-failure
no snmp-server enable traps fan-speed-change
2.Traps seen in trap receiver when disabled
Defect ID:
DEFECT000642551
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.60
Technology:
VSRP - Virtual Switch Redundancy
Protocol
Symptom:
The ICX device might reload unexpectedly.
Condition:
The commands 'no router vsrp' and 'show ip' are executed in sequence on ICX device.
Defect ID:
DEFECT000642713
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
CoA response is sent to RADIUS with source IP address not honoring "ip radius source-interface"
command.
Condition:
CoA feature is enabled. "ip radius source-interface" command is configured. ICX device receives
CoA-Request.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 39
Defect ID:
DEFECT000642973
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
The ICX device reloads randomly while issuing 'show mac-authentication session all' command.
Condition:
1. The ICX devices are in stack.
2. MAC-authentication is enabled on port in non-active unit.
3. 'show mac-authentication session all' command is executed.
Defect ID:
DEFECT000642998
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.50
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
PoE feature is non-functional after downgrading from 8061 to previous releases.
Condition:
Image Downgrade
Workaround:
"no inline power" for all ports and then reload the unit. After reload, install different FW version.
Recovery:
"no inline power" for all ports and then reload the unit. After reload, install different FW version.
Defect ID:
DEFECT000643357
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
When the ICX7450 using copper downlink port connects to the printer and the interface is configured
n half-duplex mode then over a period of multiple iterations sometimes the ping from ICX7450 to the
printer fails
Condition:
This issue happens when ICX7450 connects to a printer using downlink copper port configured in
half-duplex mode
Defect ID:
DEFECT000643449
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.50
Technology:
Mixed Stacking
Symptom:
The CB unit (ICX 7750) connected to a PE (ICX 7450) in a SPX environment might reload
unexpectedly.
Condition:
The condition is seen only when there is packet corruption observed on the SPX ports of the PE.
Defect ID:
DEFECT000643568
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Stack Failover/Switchover
Symptom:
Device may unexpectedly reload during standby election
Condition:
Reload stack setup or standby election, with CLI command history in persistant log
Workaround:
Clear CLI command history before stack reload or before standby election
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 40
Defect ID:
DEFECT000643626
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
MCT - Multi-Chassis Trunking
Symptom:
MCT peer cluster MAC is learnt on a CCEP port.
Condition:
Reload of MCT cluster nodes.
Workaround:
There is no workaround.
Recovery:
Stop all customer traffic and reload MCT cluster nodes. Since this issue is timing related, if issue is
seen after reload of MCT cluster nodes, the only option is to wait for the MCT cluster MACs to age
out at CCEP ports.
Defect ID:
DEFECT000643744
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
MAC Port-based Authentication
Symptom:
Fallback to mac-authentication does not happen for remote unit port on Stacking/SPX system
Condition:
User is connected to DUT through remote unit port and is non-dot1x capable. However, mac-
authentication does not get triggered even after timeout happens for dot1x authentication
Defect ID:
DEFECT000643843
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
Show memory command in ICX 7150 shows inaccurate information
Condition:
When show memory is used to view the memory statistics on ICX 7150
Defect ID:
DEFECT000644097
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Traditional Stacking
Symptom:
Stacking configuration is not removed during a downgrade to 8060 from 8061, though 8060 does not
support 7150 stacking
Condition:
During a Downgrade from 8061 to 8060 on a ICX 7150 Stack
Defect ID:
DEFECT000644169
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
MAC Port-based Authentication
Symptom:
Mac-authentication is not getting triggered when configured value of 'tx-period' is 3 sec
Condition:
User is dot1x not-capable and 'tx-period' is configured as 3 sec. However, User is not falling back to
mac-authentication after timeout happens for dot1x authentication. Instead session is getting cleared
for the User
Defect ID:
DEFECT000644439
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
System memory depletion with syslog or specific syslog message type is disabled.
Condition:
When syslog feature is disabled or a particular syslog message type is disabled, memory depletion is
encountered.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 41
Defect ID:
DEFECT000645534
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
Telnet user authentication is configured.
Telnet to switch results in the following:
1. The line "Please Enter Password:" is printed in the same line as "Please Enter Login Name:"
2. The telnet password is not hidden and printed.
Condition:
If the customer is using a 8061 beta build, it gets exposed to this issue.
Recovery:
Upgrade to 8061 released image or a patch build with the defect fix.
Defect ID:
DEFECT000645619
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
Occasionally ICX7250 1G access ports not going down after disabling the link partner's port. And
port remains up even though link partner state is down.
Condition:
This issue is specific to ICX7250 1G access ports and not observed with uplink or stacking ports.
Also it requires repeated port disable and enable on the link partner to see this issue.
Workaround:
Disable and re-enable ICX7250 1G port which has this issue to recover from the error state.
Defect ID:
DEFECT000645659
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Traditional Stacking
Symptom:
The statistics counters are not updated correctly. This issue is seen only internal releases and was
fixed in the final release
Condition:
Issue " show interfaces" command
Recovery:
none
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 42
Closed without code changes
This section lists software defects with Critical, High, and Medium Technical Severity closed
without a code change as of 6-July-2017 in 08.0.61.
Defect ID:
DEFECT000550376
Technical Severity:
Medium
Reason Code:
Design Limitation
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
The ports will go down if there a cable cut/fault cable. This issue is present only on 10G fiber ports
of on ICX7450 platform.
Condition:
If there is a TX/RX fiber cable cut, the link fault-signalling will not work and the ports will go down.
Fault indication will not be reflected on port status.
Workaround:
Use good quality fiber cable and keep protected.
Recovery:
Replace the fiber cable.
Defect ID:
DEFECT000600081
Technical Severity:
Medium
Reason Code:
Not Reproducible
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.40
Technology:
Syslog
Symptom:
MAU mib table ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits OIDs always return
the 00, 01
Condition:
Perform the SNMPWALK of the MAU table
snmpwalk -v2c -c public <device MGMT IP> 1.3.6.1.2.1.26.5.1.1.9.1
snmpwalk -v2c -c public <device MGMT IP> 1.3.6.1.2.1.26.5.1.1.10.1
Defect ID:
DEFECT000616501
Technical Severity:
Medium
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
ifDescr OID does not display LAG name during SNMPWALK and returns "No such instance
message for lag interface".
hq1-up-swe-10{22}: snmpwalk -v2c -c public 172.26.70.222 ifDescr
IF-MIB::ifDescr.83886043 = No Such Instance currently exists at this OID
Condition:
SNMPWalk for ifDescr on ICX device with LAG configured.
Defect ID:
DEFECT000629959
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.60
Technology:
OpenFlow
Symptom:
In ICX7750 sometimes the tagged ARP packets does not egress out when the flow is pointed to the
select group
Condition:
This happens on ICX7750 with tagged ARP packets when the flow is pointed to the select group
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 43
Defect ID:
DEFECT000632032
Technical Severity:
Low
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Port Mirroring
Symptom:
In the ICX6450 switches when the command "debug packet-capture mode pcap-fmt" with "debug
destination telnet" is run then some packet drop is observed
Condition:
This issue happens on ICX6450 switches when the command "debug packet-capture mode pcap-fmt"
with "debug destination telnet" is run
Defect ID:
DEFECT000632120
Technical Severity:
Low
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VLAN - Virtual LAN
Symptom:
During reload of the device, the ports which were member of the IP-SUBNET VLAN might not be
present and IP-SUBNET VLAN might not be formed.
Condition:
1. Create IP-SUBNET VLAN whose member should be enabled with MAC-Authentication.
2. Reload the device
Defect ID:
DEFECT000632721
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.50
Technology:
MAC Port-based Authentication
Symptom:
Failover to second radius server does not work
Condition:
When large number of users try to do mac-auth and first Radius server is down, but second radius
server is up
Defect ID:
DEFECT000632722
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.50
Technology:
NTP - Network Time Protocol
Symptom:
Show running configuration does not hold the timezone Michigan configured in ICX
Condition:
Under certain unknown conditions.
Defect ID:
DEFECT000633023
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.60
Technology:
LAG - Link Aggregation Group
Symptom:
Lag deployments having ports from Module-2(10G), were 10G speed capability is subjected to
license availability, on system reload Lag will be un-deployed if the 10G license is removed after
successfully configuring the LAG.
Condition:
LAG deployment using ports from Module-2(10G), were 10G license was available when LAG ports
were configured and subsequently before deploy if 10G license is removed. Deploy command will go
through, but 10G ports without the license will not come up physically. Also on reload this LAG will
be un-deployed to difference in configured port speed between the ports in the Lag.
Workaround:
User should apply Sica 8*10G license so as to bring the ports UP which are from module 2 and
part of an deployed LAG
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 44
Defect ID:
DEFECT000633890
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
In one of the ICX7750 unit it was observed that the switch went for one time reload without any
event or trigger
Condition:
This is a very rare case that happened in ICX7750 switch while operating normally
Defect ID:
DEFECT000633909
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.60
Technology:
Stack Management
Symptom:
Sometimes the ICX7450 switch running as a part of stack shows up error messages related to
"soc_ser_correction". This happens in a rare corner case.
Condition:
This issue is a corner case and seen with the ICX7450 switch running as a part of stack for some time
Defect ID:
DEFECT000634757
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
xSTP - Spanning Tree Protocols
Symptom:
In FastIron products, LAG ports stp states moving to blocked state when cross unit lag between ICX
7750 and ICX 7450 is reloaded
Condition:
In Fasttiron Products, configuring cross unit lag between ICX 7750 and ICX 7450 and then reload the
device will lead to LAG stp states moving to blocking state and LAG down.
Defect ID:
DEFECT000635170
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
ICX Stack breaks unexpectedly.
Condition:
When SFLOW forwarding is enabled on LAG ports and also SFLOW collector is connected through
the management port, ICX stack gets broken unexpectedly.
Defect ID:
DEFECT000635207
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
High Availability
Symptom:
The ports on the SXL 2X10G management line card might not come up.
Condition:
The 10G ports on the 2X10G management line card, when connected to any peer end port might not
come up.
Defect ID:
DEFECT000635681
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
Static Routing (IPv4)
Symptom:
BUM traffic is not flooded in the route-only ports after un-configuring route-only feature on the
interface.
Condition:
1. Configure route-only on an interface.
2. Reload the device
3. Unconfigure route-only on the interface.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 45
Defect ID:
DEFECT000636450
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
xSTP - Spanning Tree Protocols
Symptom:
In SXL devices, spanning tree status is moved into Disabled state after upgrading into 8030n image
Condition:
In SXL device, enable spanning tree on to a VLAN and reload the device will move the access port
going to disabled state.
Defect ID:
DEFECT000636598
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
Security Vulnerability
Symptom:
Client loses L3 connectivity when ARP inspection is enabled on a VLAN and Static ARP inspection
entry is configured for the client's IP-address under non-default VRF.
Condition:
ARP inspection is enabled in VLAN. Static ARP inspection entry is configured for the client under
non-default VRF.
Defect ID:
DEFECT000636733
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
Ping not working if enabled route-only on interface level of deployed lag
Condition:
1.Form the 10G lag Between Spatha1 & Spatha2
2.Configure ip address & Route-Only on primary interface
3.undeploy the lag & deploy it again
4.ping fails
Defect ID:
DEFECT000637213
Technical Severity:
Critical
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Switch reboots unexpectedly when MAC-authentication is attempted.
Condition:
1. On a Flexible Authentication enabled port , if there is an existing Dot1x session for PC in
Restricted Vlan.
2. VOIP phone attempts MAC-Authentication and Authentication is successful.
Defect ID:
DEFECT000637795
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
DHCP snooping database is not built.
Condition:
When DHCP snooping device is connected between DHCP Relay and DHCP Server, the DHCP
snooping database is not built.
Defect ID:
DEFECT000637967
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
Switch might reload unexpectedlysometimes when a Mac-Auth client in Critical or Restricted vlan, is
removed.
Condition:
Clear a Mac-Auth sessions in Critical or Restricted VLAN.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 46
Defect ID:
DEFECT000637983
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
RMON - Remote Network Monitoring
Symptom:
SNMP monitoring reads some of the stack ports as "down" when they are up. MIB value
.1.3.6.1.4.1.1991.1.1.3.31.2.2.1.8.2 might return value “3” (indicating port down) instead of value “2”
(port up) when stack port is up and forwarding.
Condition:
1) Configure snmp monitoring on the device by configuring snmp-server host ip address
2) Use SnmpGet or SnmpWalk from the snmp-server side with the OID
.1.3.6.1.4.1.1991.1.1.3.31.2.2.1.8.2
Defect ID:
DEFECT000638127
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
Static Routing (IPv4)
Symptom:
Bringing down all the ports in the VLAN does not bring down the ve interface . This leads to loop
and unnecessary traffic forwarding.
Condition:
On ICX devices data port is added as tagged/untagged to a VLAN and router-interface is added to it.
With both in up state, physically remove the cable from the port.
Defect ID:
DEFECT000638688
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
MAC-Authentication of client never succeeds if it fails once during re-authentication.
Condition:
MAC-Authentication and 802.1x are enabled on the interface. Initially MAC-authentication of client
is successful with attribute indicating not to try 802.1x for the client. During re-authentication, if
MAC-authentication fails, the client never successfully re-authenticates.
Defect ID:
DEFECT000639260
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
ICX 7450-stack memeber is not reloaded when flash Image upgrade completed with BNA via
TELNET and SCP
Condition:
1. Discover device in BNA.
2. Select transfer options as Telnet-SCP.
3. Select 'save and reload' option.
4. Load flash image from BNA to primary of device.
Defect ID:
DEFECT000639334
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.60
Technology:
802.1x Port-based Authentication
Symptom:
802.1x authentication is success for the supplicants connected to interface in member units of stack.
When the clients re-authenticate, the re-authentication fails.
Condition:
802.1x authentication is enabled on member port of stack. Period 802.1x re-authentication is also
enabled.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 47
Defect ID:
DEFECT000640054
Technical Severity:
Critical
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Error traces might be observed randomly - "Error: remaining ticks (0) is smaller than elapsed ticks"
Condition:
Switch is up and running for 621 days.
Workaround:
Reboot before 621 days of system up time. If reboot was not done in 621 days and after that if
errors are seen, then also reboot system.
Defect ID:
DEFECT000641061
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
On ICX64xx unit if the diagnostic command "dm alt-diag" is run then the failure messages are seen
on console
Condition:
This issue happens on ICX64xx unit when the diagnostic command "dm alt-diag" is run
Defect ID:
DEFECT000642197
Technical Severity:
Medium
Reason Code:
Already Fixed in Release
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
The stacked ICX7450 might get segmented, due to the stack ports bouncing back to IEEE mode from
HiGig2 mode.
Condition:
This condition is observed only when the ICX 7450 units come up after a power cycle or reload to
join the stack.
Recovery:
Manual power off/on
Defect ID:
DEFECT000642495
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Poe Firmware not upgraded due to incompatible firmware and hardware
Condition:
** This issue is NOT applicable for 8061 release and only applicable to 8030n release **
Defect ID:
DEFECT000642959
Technical Severity:
Medium
Reason Code:
Feature/Function Not Supported
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
High Availability
Symptom:
The ICX6610 Stack Active unit goes for unexpected reload with FI 8.0.30 Image
Condition:
This issue happens on ICX6610 with FI 8.0.30 image.
This defect is relevant for FI 8.0.30 release and it is not relevant for FI 8.0.61 release as this an
unsupported platform
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 48
Defect ID:
DEFECT000644253
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Software Installation & Upgrade
Symptom:
On ICX7250 running FI 8.0.30n image if the image download is performed to secondary flash then
sometime the following message is observed on console:
skipping block 1a
skipping block 1b
Condition:
This issue happens on ICX7250 switch running FI 8.0.30n build when the image download operation
is performed
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 49
Known issues
This section lists open software defects with Critical, High, and Medium Technical Severity as of
6-July-2017 in 08.0.61.
Defect ID:
DEFECT000633276
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
With full scale ACL configuration, active blocks the user from configuration changes for about 5
minutes during reload when standby is present.
Condition:
1) Large ACLs (with 1000-1500 filters) should present in the configuration.
2) Standby is coming up.
Defect ID:
DEFECT000634546
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
MRP - Metro Ring Protocol
Symptom:
On a ICX7250 stack or the ICX7450 stack when the ports are removed and added to the VLAG then
the MRP blocked ports re-converges, it moves from pre-forwarding to forwarding to blocking state
Condition:
This issue is seen on ICX7250 and ICX7450 stack when port is removed and added to the existing
VLAG
Defect ID:
DEFECT000634778
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.60
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Connected PDs in regular non fanless mode are not powered after a Reload
Condition:
Enabling fanless mode followed by a reload results in this issue - due to power allocation mechanism
Workaround:
The user can use the inline power power-limit or inline power power-by-class command for the
port where a PD is connected and need an allocation within the available power
Defect ID:
DEFECT000636438
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
CDP - Cisco Discovery Protocol
Symptom:
CDP response from the device does not carry Voice Vlan even after requesting Voice VLAN from the
other end.
Condition:
1. Configure CDP and Voice VLAN on the Brocade device
2. Send CDP response.
Defect ID:
DEFECT000636974
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Traditional Stacking
Symptom:
MAC Filters returned by Radius during Dot1x Authentication does not get applied on Stack Member
ports.
Condition:
User needs to configure MAC Filter on a dot1x port that is on a stack member
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 50
Defect ID:
DEFECT000637116
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Stack Management
Symptom:
On a SPX (Switch port extender) setup involving ICX7750 at the core stack and ICX7250 as the port
extenders, when the following steps are performed then an issue is seen where one of the port
extender unit does not get MAC address assigned and the SPX port connected to that PE unit goes in
Blocking state.
Steps to see the problem:
1. Reload the SPX stack with traffic running across the system
2. Perform the stack Switch Over on core ICX7750 stack
3. After this we observe that one of the PE unit is missing the MAC address and the SPX port
connected to that PE goes in blocking state
Condition:
This issue is seen on a SPX (Switch port extender) setup involving ICX7750 at the core stack and
ICX7250 as the port extenders, when the following steps are performed:
1. Reload the SPX stack with traffic running across the system
2. Perform the stack Switch Over on core ICX7750 stack
Defect ID:
DEFECT000637932
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
802.1x Port-based Authentication
Symptom:
ACLs do not get programmed for clients connected on stack member ports during flexible
authentication
Condition:
Observed when strict security mode is disabled
Defect ID:
DEFECT000638551
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IGMP - Internet Group Management
Protocol
Symptom:
STP states are inconsistent
Condition:
When there is standby -> member -> standby transition without reload of that unit
Workaround:
There is no workaround.
Recovery:
Reload that unit
Defect ID:
DEFECT000639235
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
LAG - Link Aggregation Group
Symptom:
Partner info fields are not filled with 0 in show lag command for up to a few minutes.
Condition:
Put the lag into mis-cabling error and then disable the whole lag.
Workaround:
There is no work around.
Recovery:
Wait for a few minutes. There is no functional impact.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 51
Defect ID:
DEFECT000639272
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
Upgrading Flash Image with TFTP-TELNET from BNA is not Working
Condition:
1. Discover device in BNA.
2. Select transfer options as Telnet-TFTP
3. Select 'save and reload' option.
4. Load flash image from BNA to primary of device.
Defect ID:
DEFECT000639914
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
IP Source Guard
Symptom:
Reload of standby results in few empty DHCP related TCAM rule entries.
Condition:
Seen after a reload of standby with scaled IPSG clients (>1000) on a port
Defect ID:
DEFECT000640693
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.61
Technology:
ARP - Address Resolution Protocol
Symptom:
Error messages corresponding to ARP and MRP show up on console during a failover of ICX 7150
stack
Condition:
Failover of a ICX 7150 stack
Defect ID:
DEFECT000640894
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.61
Technology:
IGMP - Internet Group Management
Protocol
Symptom:
After boot up “multicast router-port ethernet x/y/zis missing from the configuration.
Condition:
When device boots with "dual-mode" configuration under interface sub mode and "multicast router-
port ethe x/y/z" configured under VLAN sub mode.
Workaround:
Once the device boots-up, reconfigure command "multicast router-port ethe x/y/z".
Defect ID:
DEFECT000641382
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
Unexpected switch reload
Condition:
Condition not known.
Defect ID:
DEFECT000641399
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
Member unit reloads upon configuring a scaled ACL consisting of more than 250 filters on default
VLAN containing almost all ports of the system.
Condition:
Configuring a scaled ACL consisting of more than 250 filters on default VLAN containing almost all
ports of the system.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 52
Workaround:
Create the ACL with fewer filters and apply it to the default VLAN. Thereafter, add additional
filters to the ACL individually.
Defect ID:
DEFECT000641759
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
LAG - Link Aggregation Group
Symptom:
After an ISSU upgrade or standby reload followed by switchover, dual-mode configuration on some
of the LAG Interfaces get removed.
Condition:
Observed when sFlow and Dual mode are configured in the system
Defect ID:
DEFECT000641947
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
sFlow
Symptom:
sFlow is enabled by default on newly added ports of LAG Interface
Condition:
Seen when sFlow is already configured on some of the existing LAG ports
Workaround:
Add all ports to the LAG Interface and then selectively enable sFlow on ports where it is needed
Defect ID:
DEFECT000642164
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
On the ICX7150 if LRM adapter is connected to it without the fiber cable connection on the LRM
adapter's line side then on the ICX7150 side the port LED remains Up
Condition:
This issue happens on the ICX7150 when the LRM adapter is connected to ICX7150 without fiber
cable connected to LRM adapter
Defect ID:
DEFECT000642165
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
When the ICX7150 with LRM adapter is connected to other device and the remote port is brought
down then the ICX7150 port LED does not turn off
Condition:
This issue happens when ICX7150 using LRM adapter connects to remote port
Defect ID:
DEFECT000642234
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
SCP command to copy running-configuration does not copy complete running-configuration.
Condition:
SCP command is used to copy running-configuration of ICX device.
Defect ID:
DEFECT000642244
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
IP Source Guard
Symptom:
Some Source guard entries bound on a port do not get applied as expected with traffic
Condition:
Issue is seen after a reload when the TCAM in Hardware is full
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 53
Defect ID:
DEFECT000642580
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.61
Technology:
Hardware Monitoring
Symptom:
This issue happens in the Switch port extender setup where ICX7450 is connected as a port extender.
The LRM adapter is not supported on ICX7450. But if the user connects LRM adapter to ICX7450
working as a port extender and then the user issues "show media" CLI from control bridge then the
LRM adapter is shown in the CLI output without information indicating that it is not supported
Condition:
This issue happens in the Switch port extender setup where ICX7450 is connected as a port extender
and the LRM afapter is connected to the ICX7450 port
Defect ID:
DEFECT000643015
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
PoE Overdrive request from Ruckus R720 is not honored by ICX-7450 32ZP
Condition:
The power request from R720 is not matching the requirement. Also this feature is not supported on
the ICX 7450-32ZP in 8061.
Defect ID:
DEFECT000643426
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
Error message indicating acl hardware resource error is seen and some filters do not get programmed
Condition:
When traffic policy ACL is already applied on the interface and ACL with accounting enabled is
applied on interface.
Recovery:
Remove traffic policies. Remove and add filters which are not programmed properly.
Defect ID:
DEFECT000643836
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Traditional Stacking
Symptom:
On the ICX7450 stack setup where the 10 meter active QSFP cable is used for stacking link,
sometime the stack port flap is observed where the stack port goes down and comes back up quickly.
The issue is quite rare and seen only in some corner cases
Condition:
This issue is seen on ICX7450 stack where the 10 meter active QSFP cable is used for stacking over
40G stack ports.
Defect ID:
DEFECT000643853
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.61
Technology:
Rate Limiting and Shaping
Symptom:
Multicast port dampening on 3 unit stack, unit 3 as standby is not working after un-configuring and
re-configuring
Condition:
In a ICX7150 stack, stack unit 3 or higher is configured as standby unit. Multicast port dampening
configured on standby unit is un-configured and re-configured.
Defect ID:
DEFECT000644033
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.61
Technology:
xSTP - Spanning Tree Protocols
Symptom:
CPU is around 12% to 16%
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 54
Condition:
in scaled setup with 253 spanning tree instance
Workaround:
No workaround
Recovery:
No recovery
Defect ID:
DEFECT000644307
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
802.1x Port-based Authentication
Symptom:
No LAG option for Webauth trust-port
Condition:
When configuring LAG interface as trust port, there is no option available
Defect ID:
DEFECT000644342
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.40
Technology:
OpenFlow
Symptom:
The openflow response from ICX device has mismatched port id when compared to the request.
Condition:
Openflow request is received by ICX to create port group.
Defect ID:
DEFECT000644361
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Stack Failover/Switchover
Symptom:
Stack reload needed for priority to take effect after multiple priority changes
Condition:
Observed with source guard configuration under vlan
Workaround:
Reload the stack for priority to take effect
Defect ID:
DEFECT000644390
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
LLDP - Link Layer Discovery Protocol
Symptom:
LLDP Advertised Capabilities does not include 2.5G speed
Condition:
The device with link established for 2.5G ports
Defect ID:
DEFECT000644476
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
ACLs - Access Control Lists
Symptom:
When UDLD is enabled, LACP enabled LAG interface can flap if large ACL is applied/deleted on it.
Condition:
1) UDLD must be enabled.
2) LAG should contain ports from stack member units.
3) ACL should contain more than 1000 filters.
Workaround:
If UDLD is disabled this issue will not be seen.
Recovery:
LAG interface will come back UP after the ACL programming is completed.
Defect ID:
DEFECT000644517
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
RADIUS
Symptom:
Connecting ICX device using RADIUS over TLS secure connection fails.
Condition:
Establish TLS secure connection using RADIUS.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 55
Defect ID:
DEFECT000645489
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Unable to enforce the Voice vlan to be tagged on the ICX interfaces.
Condition:
1. Configure tagged voice VLAN.
2. PC and Phone connected to the ICX interface never acquires an IP address.
Defect ID:
DEFECT000645597
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.61
Technology:
IP Source Guard
Symptom:
A new filter added to an ACL which pertains to an IPSG entry which is earlier in the sequence order
of IPSG entries bound does not get applied
Condition:
IPv4 Filter is added to an existing configured ACL after IPSG binding happens
Workaround:
Remove and reapply the ACL
Defect ID:
DEFECT000645640
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.61
Technology:
OpenFlow
Symptom:
When openflow L2 mode is enabled on a member unit port, ping to that port succeeds. Also ARP
table is populated for the same. This causes the non openflow ports be able to send unicast traffic to
the IP/MACs learnt (in ARP table) on openflow port.
Condition:
1) Openflow is enabled on the member unit port.
2) IP address is configured on openflow interface.
3) ARP should be resolved before sending the traffic.
Workaround:
User can switch to L23 openflow mode as an alternative.
Defect ID:
DEFECT000645681
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.61
Technology:
Mixed Stacking
Symptom:
SPX standby unit is continuously crashing after performing upgrade from 8040b to 8061.
Condition:
Perform upgrade test and try to apply TFTP copy of the config before the standby is ready. This is a
timing issue.
Workaround:
Check standby is in standby ready before applying the TFTP config
Recovery:
reload will recover if crash is observed.
Defect ID:
DEFECT000646147
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.61
Technology:
CLI - Command Line Interface
Symptom:
When there are lot of ICX devices acting as DHCP clients(100+) present in the same broadcast
domain, when multiple clients started Discovery at the same time, CPU usage on some of the ICX
devices goes to 99%. In addition, they will not be able to acquire an IP address.
Condition:
When there are lot of ICX devices acting as DHCP clients(100+) present in the same broadcast
domain.
Recovery:
Reload of the ICX device that encountered the problem.
FastIron 08.0.61 for Brocade ICX Switches Release Notes Version 2 56
Defect ID:
DEFECT000646386
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.61
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
ICX device running Layer-2 Switch image, and acting as DHCP client, will not re-acquire an IP
address if it receives the NACK message from the DHCP server during RE_BIND process.
Condition:
The condition under which we observed this issue is following:
1. Multiple address pools configured on the DHCP server.
2. The interface through which the DHCP client is connected is moved to a different address pool,
before the DHCP client tried the RE_BINDing the IP address.
Workaround:
Do not change the IP address pool in such a way that you move an IP address that got leased
already.
Recovery:
Disable and followed by re-enable the DHCP client, at the global level.
Syntax:
Config# no ip dhcp-client enable
Config# ip dhcp-client enable