Ruckus ICX 7150 Switch Hardware Installation Guide Icx7150 Installguide
Ruckus ICX 7150 Switch Hardware Installation Guide icx7150-installguide
2017-12-21
User Manual: Ruckus Ruckus ICX 7150 Switch Hardware Installation Guide
Open the PDF directly: View PDF .
Page Count: 123
Download | |
Open PDF In Browser | View PDF |
HARDWARE INSTALLATION GUIDE Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Publication Date: 21 December 2017 Copyright Notice and Proprietary Information Copyright 2017 Brocade Communications Systems, Inc. All rights reserved. No part of this documentation may be used, reproduced, transmitted, or translated, in any form or by any means, electronic, mechanical, manual, optical, or otherwise, without prior written permission of or as expressly provided by under license from Brocade. Destination Control Statement Technical data contained in this publication may be subject to the export control laws of the United States of America. Disclosure to nationals of other countries contrary to United States law is prohibited. It is the reader’s responsibility to determine the applicable regulations and to comply with them. Disclaimer THIS DOCUMENTATION AND ALL INFORMATION CONTAINED HEREIN (“MATERIAL”) IS PROVIDED FOR GENERAL INFORMATION PURPOSES ONLY. BROCADE and RUCKUS WIRELESS, INC. AND THEIR LICENSORS MAKE NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THE MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE, OR THAT THE MATERIAL IS ERROR-FREE, ACCURATE OR RELIABLE. BROCADE and RUCKUS RESERVE THE RIGHT TO MAKE CHANGES OR UPDATES TO THE MATERIAL AT ANY TIME. Limitation of Liability IN NO EVENT SHALL BROCADE or RUCKUS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, DATA OR USE, INCURRED BY YOU OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT OR TORT, ARISING FROM YOUR ACCESS TO, OR USE OF, THE MATERIAL. Trademarks Ruckus Wireless, Ruckus, the bark logo, BeamFlex, ChannelFly, Dynamic PSK, FlexMaster, Simply Better Wireless, SmartCell, SmartMesh, SmartZone, Unleashed, ZoneDirector and ZoneFlex are trademarks of Ruckus Wireless, Inc. in the United States and in other countries. Brocade, the B-wing symbol, MyBrocade, and ICX are trademarks of Brocade Communications Systems, Inc. in the United States and in other countries. Other trademarks may belong to third parties. 2 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Contents Preface..........................................................................................................................................................................................................7 Document Conventions..........................................................................................................................................................................7 Notes, Cautions, and Warnings.......................................................................................................................................................7 Command Syntax Conventions.............................................................................................................................................................. 7 Document Feedback..............................................................................................................................................................................8 Ruckus Product Documentation Resources........................................................................................................................................... 8 Online Training Resources...................................................................................................................................................................... 8 Contacting Ruckus Customer Services and Support..............................................................................................................................9 What Support Do I Need?...............................................................................................................................................................9 Open a Case...................................................................................................................................................................................9 Self-Service Resources................................................................................................................................................................... 9 About This Document..................................................................................................................................................................................11 Supported hardware and software....................................................................................................................................................... 11 What's new in this document............................................................................................................................................................... 12 Device Overview..........................................................................................................................................................................................13 Hardware features................................................................................................................................................................................13 License options....................................................................................................................................................................................14 Port-side view...................................................................................................................................................................................... 15 Nonport-side view................................................................................................................................................................................ 17 Device management options................................................................................................................................................................ 19 LRM Adapter support.......................................................................................................................................................................... 19 Preparing for the Installation........................................................................................................................................................................ 21 Safety precautions............................................................................................................................................................................... 21 General precautions...................................................................................................................................................................... 21 ESD precautions........................................................................................................................................................................... 21 Power precautions........................................................................................................................................................................ 22 Lifting and weight-related precautions...........................................................................................................................................22 Laser precautions......................................................................................................................................................................... 23 Facility requirements.............................................................................................................................................................................23 Quick installation checklist....................................................................................................................................................................24 Pre-installation tasks..................................................................................................................................................................... 24 Installation and initial configuration................................................................................................................................................ 24 Shipping carton contents..................................................................................................................................................................... 26 Mounting the Device....................................................................................................................................................................................27 Mounting options................................................................................................................................................................................. 27 Precautions specific to mounting..........................................................................................................................................................27 Mounting on a desktop or flat surface.................................................................................................................................................. 28 Mounting the compact device with a magnet....................................................................................................................................... 30 Attaching the magnet sheet to the device..................................................................................................................................... 31 Mounting the device on a metal surface or metal wall....................................................................................................................32 Mounting the device under a metal desk.......................................................................................................................................34 Mounting the compact device under a fixed surface.............................................................................................................................36 Mounting the compact device directly on a wall................................................................................................................................... 39 Mounting on a wall using the wall mount brackets................................................................................................................................43 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 3 Mounting on a two-post rack............................................................................................................................................................... 48 Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295)................................................................................53 Time and items required.......................................................................................................................................................................54 Parts list............................................................................................................................................................................................... 54 Flush-front mounting the device in the rack.......................................................................................................................................... 55 Attaching the front brackets.......................................................................................................................................................... 56 Attaching the bracket extensions to the device............................................................................................................................. 57 Installing the device in the rack......................................................................................................................................................58 Attaching the rear brackets to the extensions................................................................................................................................59 Attaching the rear brackets to the rack posts................................................................................................................................ 61 Flush-rear (recessed) mounting the device in the rack.......................................................................................................................... 62 Attaching the front brackets to the rear of the device.................................................................................................................... 62 Attaching the bracket extensions to the front of the device............................................................................................................63 Installing the device in the rack......................................................................................................................................................64 Attaching the rear brackets to the bracket extensions at the front of the device............................................................................ 65 Attaching the rear brackets to the front rack posts........................................................................................................................ 67 Connecting ICX 7150 Devices in a Stack.....................................................................................................................................................69 Stacking configuration requirements.....................................................................................................................................................69 ICX 7150 stacking ports.......................................................................................................................................................................69 ICX 7150 stacking topologies...............................................................................................................................................................71 Initial Setup and Verification......................................................................................................................................................................... 75 Items required...................................................................................................................................................................................... 75 Providing power to the device.............................................................................................................................................................. 75 Establishing a first-time connection to the console port........................................................................................................................ 76 Recovering from a lost password.................................................................................................................................................. 78 Configuring an IP address for the device.............................................................................................................................................. 79 Customizing the host name and chassis name ....................................................................................................................................79 Setting the date and time..................................................................................................................................................................... 80 Establishing a connection to the out-of-band management port...........................................................................................................80 Getting in-band access........................................................................................................................................................................ 81 Verifying the correct operation.............................................................................................................................................................. 81 Backing up the running configuration................................................................................................................................................... 81 Installing Transceivers and Cables............................................................................................................................................................... 83 Time and items required.......................................................................................................................................................................83 Precautions specific to transceivers and cables....................................................................................................................................83 Managing cables..................................................................................................................................................................................84 Installing the Ethernet RJ-45 cables..................................................................................................................................................... 84 Cleaning the fiber-optic connectors...................................................................................................................................................... 86 Installing a new fiber-optic transceiver.................................................................................................................................................. 86 Cabling a fiber-optic transceiver........................................................................................................................................................... 87 Replacing a fiber-optic transceiver........................................................................................................................................................88 Monitoring the Device..................................................................................................................................................................................91 Interpreting port-side LEDs.................................................................................................................................................................. 91 System LEDs................................................................................................................................................................................ 93 OOB LED......................................................................................................................................................................................97 RJ-45 Ethernet port status LED in default mode........................................................................................................................... 97 Interpreting nonport-side LEDs.............................................................................................................................................................98 Pinging an IP address.......................................................................................................................................................................... 98 4 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Tracing a route..................................................................................................................................................................................... 98 Digital optical monitoring...................................................................................................................................................................... 99 Monitoring power and cooling.............................................................................................................................................................. 99 Ruckus ICX 7150 Switch Technical Specifications..................................................................................................................................... 101 System specifications.........................................................................................................................................................................101 Ethernet............................................................................................................................................................................................. 102 LEDs.................................................................................................................................................................................................. 102 Other................................................................................................................................................................................................. 103 Weight and physical dimensions.........................................................................................................................................................103 Environmental requirements............................................................................................................................................................... 103 Power supply specifications (per PSU)............................................................................................................................................... 104 Power consumption (idle configuration).............................................................................................................................................. 105 Power consumption (typical configuration)......................................................................................................................................... 106 Power consumption (maximum configuration).................................................................................................................................... 107 Data port specifications (Ethernet)...................................................................................................................................................... 108 Serial port specifications (pinout RJ-45)..............................................................................................................................................109 Serial port specifications (protocol)..................................................................................................................................................... 109 Memory specifications........................................................................................................................................................................109 Regulatory compliance (EMC)............................................................................................................................................................ 110 Regulatory compliance (safety)........................................................................................................................................................... 110 Regulatory compliance (environmental).............................................................................................................................................. 110 Regulatory Statements.............................................................................................................................................................................. 111 CE statement..................................................................................................................................................................................... 111 China ROHS...................................................................................................................................................................................... 111 BSMI statement (Taiwan).................................................................................................................................................................... 111 Canadian requirements...................................................................................................................................................................... 112 China CCC statement........................................................................................................................................................................ 112 Europe and Australia (CISPR 32 Class A Warning)..............................................................................................................................113 FCC warning (US only)....................................................................................................................................................................... 113 Germany statement............................................................................................................................................................................113 KCC statement (Republic of Korea).................................................................................................................................................... 113 VCCI statement..................................................................................................................................................................................113 Cautions and Danger Notices....................................................................................................................................................................115 Cautions............................................................................................................................................................................................ 115 General cautions......................................................................................................................................................................... 115 Electrical cautions....................................................................................................................................................................... 117 Danger Notices.................................................................................................................................................................................. 118 General dangers......................................................................................................................................................................... 119 Electrical dangers........................................................................................................................................................................119 Dangers related to equipment weight..........................................................................................................................................121 Laser dangers.............................................................................................................................................................................122 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 5 6 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Preface • • • • • • Document Conventions............................................................................................................................................. 7 Command Syntax Conventions................................................................................................................................. 7 Document Feedback................................................................................................................................................. 8 Ruckus Product Documentation Resources.............................................................................................................. 8 Online Training Resources......................................................................................................................................... 8 Contacting Ruckus Customer Services and Support................................................................................................. 9 Document Conventions The following tables list the text and notice conventions that are used throughout this guide. TABLE 1 Text conventions Convention Description monospace Example Identifies command syntax examples. bold User interface (UI) components such as screen or page names, keyboard keys, software buttons, and field names On the Start menu, click All Programs. italics Publication titles Refer to the Ruckus Small Cell Release Notes for more information device(config)# interface ethernet 1/1/6 Notes, Cautions, and Warnings Notes, cautions, and warning statements may be used in this document. They are listed in the order of increasing severity of potential hazards. NOTE A NOTE provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information. CAUTION A CAUTION statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A DANGER statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations. Command Syntax Conventions Bold and italic text identify command syntax components. Delimiters and operators define groupings of parameters and their logical relationships. Convention Description bold text Identifies command names, keywords, and command options. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 7 Preface Document Feedback Convention Description italic text Identifies a variable. [] Syntax components displayed within square brackets are optional. Default responses to system prompts are enclosed in square brackets. {x|y|z} A choice of required parameters is enclosed in curly brackets separated by vertical bars. You must select one of the options. x|y A vertical bar separates mutually exclusive elements. <> Nonprinting characters, for example, passwords, are enclosed in angle brackets. ... Repeat the previous element, for example, member[member...]. \ Indicates a “soft” line break in command examples. If a backslash separates two lines of a command input, enter the entire command at the prompt without the backslash. Document Feedback Ruckus is interested in improving its documentation and welcomes your comments and suggestions. You can email your comments to Ruckus at: docs@ruckuswireless.com When contacting us, please include the following information: • Document title and release number • Document part number (on the cover page) • Page number (if appropriate) • For example: – – – Ruckus Small Cell Alarms Guide SC Release 1.3 Part number: 800-71306-001 Page 88 Ruckus Product Documentation Resources Visit the Ruckus website to locate related documentation for your product and additional Ruckus resources. Release Notes and other user documentation are available at https://support.ruckuswireless.com/documents. You can locate documentation by product or perform a text search. Access to Release Notes requires an active support contract and Ruckus Support Portal user account. Other technical documentation content is available without logging into the Ruckus Support Portal. White papers, data sheets, and other product documentation are available at https://www.ruckuswireless.com. Online Training Resources To access a variety of online Ruckus training modules, including free introductory courses to wireless networking essentials, site surveys, and Ruckus products, visit the Ruckus Training Portal at https://training.ruckuswireless.com. 8 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Preface Contacting Ruckus Customer Services and Support Contacting Ruckus Customer Services and Support The Customer Services and Support (CSS) organization is available to provide assistance to customers with active warranties on their Ruckus Networks products, and customers and partners with active support contracts. For product support information and details on contacting the Support Team, go directly to the Support Portal using https:// support.ruckuswireless.com, or go to https://www.ruckuswireless.com and select Support. What Support Do I Need? Technical issues are usually described in terms of priority (or severity). To determine if you need to call and open a case or access the selfservice resources use the following criteria: • Priority 1 (P1)—Critical. Network or service is down and business is impacted. No known workaround. Go to the Open a Case section. • Priority 2 (P2)—High. Network or service is impacted, but not down. Business impact may be high. Workaround may be available. Go to the Open a Case section. • Priority 3 (P3)—Medium. Network or service is moderately impacted, but most business remains functional. Go to the Self-Service Resources section. • Priority 4 (P4)—Low. Request for information, product documentation, or product enhancements. Go to the Self-Service Resources section. Open a Case When your entire network is down (P1), or severely impacted (P2), call the appropriate telephone number listed below to get help: • Continental United States: 1-855-782-5871 • Canada: 1-855-782-5871 • Europe, Middle East, Africa, and Asia Pacific, toll-free numbers are available at https://support.ruckuswireless.com/contact-us and Live Chat is also available. Self-Service Resources The Support Portal at https://support.ruckuswireless.com/contact-us offers a number of tools to help you to research and resolve problems with your Ruckus products, including: • Technical Documentation—https://support.ruckuswireless.com/documents • Community Forums—https://forums.ruckuswireless.com/ruckuswireless/categories • Knowledge Base Articles—https://support.ruckuswireless.com/answers • Software Downloads and Release Notes—https://support.ruckuswireless.com/software • Security Bulletins—https://support.ruckuswireless.com/security Using these resources will help you to resolve some issues, and will provide TAC with additional data from your troubleshooting analysis if you still require assistance through a support case or RMA. If you still require help, open and manage your case at https:// support.ruckuswireless.com/case_management Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 9 10 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 About This Document • • Supported hardware and software.......................................................................................................................... 11 What's new in this document.................................................................................................................................. 12 Supported hardware and software This document is applicable for the various Ruckus ICX 7150 Ethernet switch models. The following tables list the device models and rack mount kits supported. TABLE 2 OS-dependent models Model number Short description Introduced (OS) Currently supported (OS) Notes ICX 7150-48ZP Sixteen 2.5G and thirty-two 1G Copper ports with eight SFP+ 1G/10-GbE ports - four are optical stacking or uplink ports, and four are uplink ports only FastIron 08.0.61 Yes hot-swap fan tray (up to 2 per switch) Twelve GbE (124 W) PoE+ ports with two 1-GbE uplink ports and two SFP+ 10-GbE optical stacking or uplink ports FastIron 08.0.60 Twenty-four GbE non-PoE ports with two 1-GbE uplink ports and four SFP+ 10-GbE optical stacking or uplink ports FastIron 08.0.60 Twenty-four GbE (370 W) PoE+ ports with two 1GbE uplink ports and four SFP+ 10-GbE optical stacking or uplink ports FastIron 08.0.60 ICX 7150-C12P ICX 7150-24 ICX 7150-24P Mountable on a desktop, rack, or wall Yes Fanless Mountable on a desktop, rack, wall, under a fixed surface, under a desk, under a shelf, or using a magnet Yes Fanless Mountable on a desktop, rack, or wall Yes Two built-in fans Support fanless mode Mountable on a desktop, rack, or wall ICX 7150-48 ICX 7150-48P Forty-eight GbE non-PoE ports with two 1-GbE uplink ports and four SFP+ 10-GbE optical stacking or uplink ports FastIron 08.0.60 Forty-eight GbE (370 W) PoE+ ports with two 1GbE uplink ports and four SFP+ 10-GbE optical stacking or uplink ports FastIron 08.0.60 Yes Fanless Mountable on a desktop, rack, or wall Yes Two built-in fans Support fanless mode Mountable on a desktop, rack, or wall ICX 7150-48PF Forty-eight GbE (740 W) PoE+ ports with two 1GbE uplink ports and four SFP+ 10-GbE optical stacking or uplink ports Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 FastIron 08.0.60 Yes Three built-in fans Mountable on a desktop, rack, or wall 11 About This Document What's new in this document NOTE For ICX 7150-C12P, ICX 7150-24, ICX 7150-24P, ICX 7150-48, ICX 7150-48P, and ICX 7150-48PF, the AC power supply and fans are integrated with the device. The power supply or the fans are not field replaceable units (FRUs). TABLE 3 Rack mount kits Part number Short description Notes ICX6400-C12-MGNT Magnet mount kit for ICX 7150-C12P. This is not a rack mount kit. It is a magnet which could be used on a rack or on any surface that is magnetic such as a metal desk or cabinet Not included with the device. Optionally orderable. ICX7000-C12-RMK Rack mount kit for ICX 7150-C12P on 2-post racks Not included with the device. Optionally orderable. ICX7000-C12-WMK Wall / under desk mount kit for ICX 7150-C12P Not included with the device. Optionally orderable. ICX7000-RMK Rack mount kit for 2-post racks Included with 24-port and 48-port ICX 7150 models. XBR-R000295 Universal rack mount kit for 4-post racks Not included with the device. Optionally orderable. RMK-LRM-ADP Rack mount kit for LRM adapters. 1RU shelf can accommodate up to eight LRM adapters. Not included with the device. Optionally orderable. TABLE 4 Supported Adapter Adapter Type Short description Notes 10G LRM SFP + Adapter 10GE SFP+ adapter for LRM optics Not included with the device. Optionally orderable. What's new in this document The following table includes descriptions of new information added to this guide for the FastIron 08.0.70 release. TABLE 5 Summary of enhancements in FastIron release 08.0.70 Feature Description Described in Status Button Support You must press the status mode selection button to select the status mode to display the corresponding status on the individual port status LED. Status mode LEDs on page 94 Updates to LED Several updates to the LED status. Refer to the topics under Interpreting port-side LEDs on page 91. 12 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Device Overview • • • • • • Hardware features................................................................................................................................................... 13 License options....................................................................................................................................................... 14 Port-side view......................................................................................................................................................... 15 Nonport-side view................................................................................................................................................... 17 Device management options................................................................................................................................... 19 LRM Adapter support..............................................................................................................................................19 Hardware features The Ruckus ICX 7150 offers the following hardware features and capabilities: • ICX 7150 Z-series new for this release have the following features: – – – – – – – • 16 2.5G+ Copper ports , that support 100M/1G/2.5G operation. 32 1G Copper ports, that support 10M/100M/1G operation. 8 SFP+ Fiber Ports supporting 1G/10G operation , in which the first 4 ports can be configured as stacking ports and the last 4 ports can be used for uplink/user port. The ports 1/2/1 and 1/2/3 comes up in 10G speed by default. The other ports comes up in 1G speed default , enabling 10G on these ports requires a software license. The ports 1/2/1 through 1/2/4 can be configured as stacking port or as user/uplink ports, where as 1/2/5 through 1/2/8 can be configured as user/uplink ports. The first 16 ports complies with the power-over-HDBase T and each port can provide up to 90W. The 32 1G Copper ports complies with the IEEE 802.3af/at standard. The table below lists the ICX 7150 switch models with 12, 24, or 48 auto-negotiating 10/100/1000 Mbps full duplex RJ-45 ports that can be used for downlink. These ports reside on slot 1 of the switch and can be non-PoE, PoE/POE+, or PoE+ ports. TABLE 6 Switch model and corresponding IO port configurations Switch model Down Link Ports PoE Ports PoE Power Up Link / Stacking Ports Stacking Ports ICX 7150-48 48x1G Copper NA NA 2x1G Copper + 4xSFP + 2xSFP+ ICX 7150-48P 48x1G Copper 48 370W 2x1G Copper + 4xSFP+ 2xSFP+ ICX 7150-48PF 48x1G Copper 48 740W 2x1G Copper +4xSFP+ 2xSFP+ ICX 7150-24 24x1G Copper NA NA 2x1G Copper + 4xSFP+ 2xSFP+ ICX 7150-24P 24x1G Copper 24 370W 2x1G Copper + 4xSFP+ 2xSFP+ ICX 7150-C12P 12x1G Copper 12 124W 2x1G Copper + 2xSFP 2xSFP+ ICX 7150-48ZP 16x2.5G Copper 32x 1G Copper 48 1480W 4xSFP + 8xSFP 4xSFP+ • Two 10/100/1000Base-T full duplex RJ-45 ports that can be used as uplink data ports. These ports reside on slot 2 of the switch. • Two or four SFP+ optical 10-Gbps full duplex ports that can be used as stacking or uplink data ports. These ports reside on slot 3 of the switch. • 10-GbE SFP+ dongle for LRM optic (Now supported in this release and onwards). • Switch Port Extender (PE) mode (not supported currently). • Maximum two FRUs power supply units. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 13 Device Overview License options • Maximum two FRU fans for cooling the system with sides-to-back airflow. • System LEDs – – – – – • Status mode LEDs (not enabled currently). – – – – – • Power status DIAG status Master/Slave status Cloud management status (not enabled currently). Software update status (not enabled currently). Port link status mode Port speed status mode PoE status mode Member ID status mode USB modes Management interfaces – – – – – – Mode switch button (not enabled currently) Reset button Out-of-band (OOB) GbE management port USB 2.0 general purpose Type-A port for file transfer with removable media (removable media not included with the device) Type-C USB console port (Type-C USB cable not included with the device) RS-232 console port with RJ-45 form factor (RJ-45 console cable not included with the device) License options The following table displays Ruckus ICX 7150 part number and license information available when upgrading to a licensed feature set. The licensed feature set includes the Premium Layer 3 license, and the Ports on Demand license. When upgrading to a licensed feature set, a Certificate of Entitlement (CoE) is shipped to you upon purchase of the license. The CoE is a “proof of purchase” for any features that have been purchased. The CoE is a .PDF certificate that has a unique serial number. One CoE is issued for each feature license that is purchased. Refer to the Brocade FastIron Software Licensing Guide for more details. TABLE 7 Ruckus ICX 7150 SKU and license information Part Number for Upgrades License Name Description BR-ICX-7150-41U210-P-01 2X10G CoE license to upgrade any ICX 7150 24-port or 48-port model from 4x1G SFP to a 2x1G SFP and 2x10G SFP+ uplink or stacking ports. BR-ICX-7150-210U410R-P-01 4X10GR CoE license to upgrade any ICX 7150 24-port or 48-port model from 2x1G SFP and 2x10G SFP+ to a 4x10G SFP+ uplink or stacking ports. Two default ports are available for stacking. Layer 3 Premium license features (OSPF, VRRP, PIM, PBR) are also included. BR-ICX-7150-41U410R-P-01 4X10GR CoE license to upgrade any ICX 7150 24-port or 48-port model from 4x1G SFP to a 4x10G SFP+ uplink or stacking ports. Two default ports are available for stacking. Layer 3 Premium license features (OSPF, VRRP, PIM, PBR) are also included. BR-ICX-7150C-21U210R-P-01 2X10GR CoE license to upgrade the ICX 7150-C12P switch from 2x1G SFP to a 2x10G SFP+ uplink or stacking ports. Layer 3 Premium license features (OSPF, VRRP, PIM, PBR) are also included. BR-ICX-7150Z210U810R-P-01 8X10GR CoE license to upgrade an ICX 7150-48ZP Z-Series switch from 6x1G SFP & 2x10G SFP+ to 8x10G SFP+ uplink or stacking ports. Layer 3 Premium license features (OSPF, VRRP, PIM, PBR) are also included. 14 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Device Overview Port-side view Port-side view FIGURE 1 Port-side view of ICX 7150-C12P 1. Type-C USB console port 10. RJ-45 uplink port C2 RX/TX activity LED 2. Port status mode selection button and LEDs 11. Reserved for future use 3. System LEDs 12. RJ-45 downlink port 8 RX/TX activity LED 4. Slot 1 (10/100/1000 Mbps RJ-45 downlink) ports 13. Out-of-band management port (RJ-45) with 2 LEDs 5. Slot 2 (10/100/1000 Mbps RJ-45 uplink) ports (half-duplex is not support on these ports) 6. Slot 3 (SFP+ uplink or stacking ports) 7. SFP+ Port X2 status LED 8. SFP+ Port X1 status LED 9. Reserved for future use Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 a. Left LED - Off: Link-down, Steady green: Link-up, and Blinking green: when there is RX/TX activity b. Right LED - Off: when offline or linked at 10/100Mbps, Blinking green: when there is RX/TX activity 14. USB port 15. RJ-45 console port 16. Reset button 15 Device Overview Port-side view FIGURE 2 Port-side view of ICX 7150-24 and ICX 7150-24P 1. Type-C USB console port 2. Port status mode selection button and LEDs 3. System LEDs 4. RJ-45 downlink port 17 status LED 5. RJ-45 downlink port 17 RX/TX activity LED 6. RJ-45 uplink port C1 status LED 7. RJ-45 uplink port C1 RX/TX activity LED 8. SFP+ port X1 status LED 9. SFP+ port X2 status LED 10. Slot 3 (SFP+ uplink or stacking) ports 11. Slot 2 (10/100/1000 Mbps RJ-45 uplink) ports (half-duplex is not support on these ports) 12. Slot 1 (10/100/1000 Mbps RJ-45 downlink) ports 13. USB port 14. Out-of-band management port (RJ-45) with 2 LEDs a. Left LED - Off: Link-down, Steady green: Link-up, and Blinking green: when there is RX/TX activity b. Right LED - Off: when offline or linked at 10/100Mbps, Blinking green: when there is RX/TX activity 15. RJ-45 console port 16. Reset button 11. Slot 2 (10/100/1000 Mbps RJ-45 uplink) ports (half-duplex is not support on these ports) 12. Slot 1 (10/100/1000 Mbps RJ-45 downlink) ports 1-48 13. USB port 14. Out-of-band management port (RJ-45) with 2 LEDs FIGURE 3 Port-side view of ICX 7150-48, ICX 7150-48P, and ICX 7150-48PF 16 1. Type-C USB console port 2. Port status mode selection button and LEDs 3. System LEDs 4. RJ-45 downlink port 29 status LED 5. RJ-45 downlink port 29 RX/TX activity LED 6. RJ-45 uplink port C1 status LED 7. RJ-45 uplink port C1 RX/TX activity LED 8. SFP+ port X1 status LED 9. SFP+ port X2 status LED 10. Slot 3 (SFP+ uplink or stacking) ports 15. a. Left LED - Off: Link-down, Steady green: Link-up, and Blinking green: when there is RX/TX activity b. Right LED - Off: when offline or linked at 10/100Mbps, Blinking green: when there is RX/TX activity Reset button Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Device Overview Nonport-side view FIGURE 4 Port-side view of ICX 7150-48ZP 1. Type-C USB console port 9. 1G PoE-2 pair user Ports 17 - 48 2. Pushbutton to cycle through Mode LEDs 10. 2.5G PoE-2 pair user Ports 1-16 3. Mode LEDs 11. Type-A USB port 4. System LEDs 12. Out-of-band management port (RJ-45) with 2 LEDs 5. Reset Button 6. Venting holes 7. Logo and Model name 8. SFP+ Fiber Stacking/Uplink ports a. Left LED - Off: Link-down, Steady green: Link-up, and Blinking green: when there is RX/TX activity b. Right LED - Off: when offline or linked at 10/100Mbps, Blinking green: when there is RX/TX activity Nonport-side view FIGURE 5 Nonport-side view of ICX 7150-C12P 1. Kensington security slot 2. AC power supply socket FIGURE 6 Nonport-side view of ICX 7150-24 1. AC power supply socket Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 17 Device Overview Nonport-side view FIGURE 7 Nonport-side view of ICX 7150-48 1. Management console port - RJ-45 2. AC power supply socket 3. Management console port - RJ-45 (available in the front panel for ICX 7150-24P) 4. AC power supply socket FIGURE 8 Nonport-side view of ICX 7150-24P and ICX 7150-48P 1. Fan 1 2. Fan 2 FIGURE 9 Nonport-side view of ICX 7150-48PF 1. Fan 1 4. Management console port - RJ-45 2. Fan 2 5. AC power supply socket 3. Fan 3 FIGURE 10 Nonport-side view of ICX 7150-48ZP 18 1. Fan 1 4. 920W PSU with 740W of PoE budget 2. Fan 2 5. 920W PSU with 740W of PoE budget 3. Management console port - RJ-45 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Device Overview LRM Adapter support Device management options You can use the management functions built into the device to monitor the topology, port status, physical status, and other information to help you analyze switch performance and to accelerate system debugging. The device automatically performs power-on self-test (POST) each time it is turned on. Any errors are recorded in the syslog messages. You can manage the device using any of the management options listed in the following table. TABLE 8 Management options for the device Management tool Out-of-band support Reference documents Command line interface (CLI) Ethernet, serial connection, or USB console Brocade FastIron Command Reference Guide Standard SNMP applications Ethernet or serial connection Unified IP MIB Reference Guide Brocade FastIron Web Management Interface Ethernet or connection via IP address Brocade FastIron Web Management Interface User Guide Feature-based Configuration Guides NOTE Not all FastIron features are supported via the web management interface. Brocade Network Advisor (BNA) Ethernet or serial connection Brocade Network Advisor documentation set NOTE BNA must be purchased separately. LRM Adapter support Some ICX switches do not support Long Reach Module (LRM) optics on 10G fiber ports. LRM adapter can connect to any 10G fiber ports of the ICX switch. It has two 10G fiber ports and both ports can be used at the same time. The LRM Adapter is supported on all 10G fiber ports for all models of the ICX7150 Family of switches. Below is the front view of the LRM adapter and the SPF+ Optic module with copper pigtail. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 19 Device Overview LRM Adapter support FIGURE 11 LRM Adapter front view 1. Port Status LEDs (see per Port LED status definition below) c. Amber off, Green on : Link Up a. Amber off, Green off : No Power d. Amber off, Green Blinking : Link activity b. Amber on, Green off : Link down 2. Panel Label FIGURE 12 SPF+ Optic module with copper pigtail NOTE The LRM adapter is used to support LRM optics on the ICX7750, ICX7250 and ICX7150 switches. The ICX7450 support LRM optics natively. 20 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Preparing for the Installation • • • • Safety precautions...................................................................................................................................................21 Facility requirements................................................................................................................................................23 Quick installation checklist.......................................................................................................................................24 Shipping carton contents........................................................................................................................................ 26 Safety precautions When using this product, observe all danger, caution, and attention notices in this manual. The safety notices are accompanied by symbols that represent the severity of the safety condition Refer to Cautions and Danger Notices at the end of this guide for translations of safety notices for this product. General precautions DANGER The procedures in this manual are for qualified service personnel. DANGER Before beginning the installation, see the precautions in “Power precautions.” DANGER The equipment ports are intra-building type and must not be directly connected to metallic outside plant (OSP) cable conductors. CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. CAUTION Make sure the airflow around the front, and back of the device is not restricted. CAUTION Never leave tools inside the chassis. CAUTION To protect the serial port from damage, keep the cover on the port when not in use. CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 45°C (113°F). ESD precautions DANGER For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 21 Preparing for the Installation Safety precautions CAUTION Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface. CAUTION Static electricity can damage the chassis and other electronic devices. To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them. NOTE Wear a wrist grounding strap connected to the chassis ground (if the device is plugged in) or to a bench ground. Power precautions DANGER Make sure that the power source circuits are properly grounded. DANGER Make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device. DANGER To reduce the risk of electric shock, disconnect all power cords before servicing. DANGER Disconnect the power cord from all power sources to completely remove power from the device. DANGER To avoid high voltage shock, do not open the device while the power is on. DANGER Batteries used for RTC/NVRAM backup are not located in operator-access areas. There is a risk of explosion if a battery is replace by an incorrect type. Dispose of used components with batteries according to local ordinance and regulations. CAUTION Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the input power connectors. Lifting and weight-related precautions DANGER Use safe lifting practices when moving the product. DANGER Mount the devices you install in a rack as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above. 22 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Preparing for the Installation Facility requirements DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. CAUTION Do not use the port cover tabs to lift the module. They are not designed to support the weight of the module, which can fall and be damaged. Laser precautions DANGER All fiber-optic interfaces use Class 1 lasers. DANGER Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do not comply with these standards might emit light that is hazardous to the eyes. Facility requirements Before installing the device, be sure the following facilities requirements are met. TABLE 9 Facility requirements Type General Electrical Requirements • The site should be accessible for installing, cabling, and maintaining the devices. • Maintain the operating environment as specified in the Technical Specifications. • Allow at least 7.62 cm (3 in.) of space between the front and the back of the device and walls or other obstructions for proper airflow. • Allow at least 7.62 cm (3 in.) of space at the front and back of the device for the twisted-pair, fiber-optic, and power cabling. • Allow the status LEDs to be clearly visible. • Allow for the unit to be connected to a separate grounded power outlet that provides 100 to 240 VAC, 50/60 Hz, within 2 m (6.6 ft) of each device, and is powered from an independent circuit breaker. As with any equipment, a filter or surge suppressor is recommended. • Allow for twisted-pair cables to be routed away from power lines, fluorescent lighting fixtures, and other sources of electrical interference, such as radios and transmitters. • Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate • Circuit protected by a circuit breaker and grounded in accordance with local electrical codes Refer to the Technical Specifications at the end of this guide for complete power supply specifications. Thermal • A minimum airflow of 39.1 cubic meters/hour (23 cubic ft/min.) available in the immediate vicinity of the switch NOTE Although this airflow may exceed the airflow maximum listed in the device Technical Specifications, the additional airflow is recommended to pressurize the inlet (cool isle) side of rack installations relative to the exhaust side to minimize recirculation of hot air back to the inlet side. Rack (when rackmounted) • Ambient air temperature not exceeding 45°C (113°F) while the switch is operating • One rack unit (1U) in a 48.3 cm (19-inch) rack • All equipment in the rack grounded through a reliable branch circuit connection Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 23 Preparing for the Installation Quick installation checklist TABLE 9 Facility requirements (continued) Type Requirements • Additional weight of switch not to exceed the rack’s weight limits • Temperature: Because the temperature within a rack assembly may be higher than the ambient room temperature, check that the rack-environment temperature is within the specified operating temperature range. • Airflow: Be sure that the airflow direction for all equipment in a rack is the same or consistent. • Mechanical loading: Do not place any equipment on top of a rack-mounted unit. • Rack secured to ensure stability in case of unexpected movement • Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded. Quick installation checklist The following checklist provides a high-level overview of the basic installation process from the planning stage to the point where the device comes online and is ready to be deployed. Completing all the tasks in the suggested order ensures successful installation. Brocade recommends that you print this checklist and take it to the installation site. Pre-installation tasks Review all installation requirements ahead of time as part of your site preparation. Careful planning and site preparation ensures seamless installation, especially when installing multiple devices. TABLE 10 Installation prerequisites Task Task details or additional information Unpack the device. Take an inventory of the hardware components included in your shipment. Refer to Shipping carton contents on page 26. Gather necessary components and required tools. Review the time and items required information at the beginning of each chapter to ensure you have gathered all necessary components required for the following installation tasks: • Mounting the Device on page 27. • Installing Transceivers and Cables on page 83. Completed Review the safety precautions. Refer to Safety precautions on page 21. For translation of these messages, refer to Cautions and Danger Notices on page 115. Plan the installation. Decide whether you want to install the unit on a flat surface or in a rack. For rack installation, obtain the appropriate rack mount kit. Refer to Mounting options on page 27. Review and verify installation requirements. Verify that the following requirements are met. Refer to Facility requirements on page 23. Gather network configuration parameters. • General requirements • Power requirements • Environmental requirements • Clearance for standalone or rack installation • IP address: • Subnet mask: • Default gateway: • Time zone: Installation and initial configuration The initial setup includes mounting the device on a flat surface or in a rack and completing the configuration tasks necessary to bring the device online and verify the operation. 24 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Preparing for the Installation Quick installation checklist TABLE 11 Installation and basic system configuration Task Task details or additional information Mount the device. Choose one of the following mounting options: • Mount the device on a desktop or flat surface. Refer to Mounting on a desktop or flat surface on page 28. • Mount the compact device with a magnet. Refer to Mounting the compact device with a magnet on page 30. • Mount the compact device under a fixed surface or desk. Refer to Mounting the compact device under a fixed surface on page 36. • Mount the compact device directly on a wall. Refer to Mounting the compact device directly on a wall on page 39 • Mount the device on a wall using the wall mount brackets. Refer to Mounting on a wall using the wall mount brackets on page 43. • Mount the device on a two-post rack. Refer to Mounting on a two-post rack on page 48. • Mount the device on a universal four-post rack. Refer to Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295) on page 53. Gather all components required for the initial setup. Refer to Items required on page 75. Provide power to the device. Refer to Providing power to the device on page 75. Attach a management station, establish a console connection, and configure the various levels of passwords. Refer to Establishing a first-time connection to the console port on page 76. After completing this task, log in to the console port to configure the device. Set the IP address, subnet mask, and the default gateway IP address. Use the ip address command to configure a static device IP address, subnet mask, and gateway IP address, or you can use a DHCP server to obtain the information dynamically. Refer to Configuring an IP address for the device on page 79. Set the date and time • Use the clock set command to set the current date and time for the device. Refer to Setting the date and time on page 80 for more information. Customize the host name and chassis name. Establish a connection to the out-of-band management port. Verify that the device operates correctly. • Use the hostname command to change the default host name and CLI prompt. • Use the chassisname command to change the default chassis name or ID. Refer to Customizing the host name and chassis name on page 79 for more information. By establishing a connection to the out-of-band management port, you can complete the device configuration using an SSH session, Telnet, or management application, such as Brocade Network Advisor. Refer to Establishing a connection to the out-of-band management port on page 80. • Check the LEDs to verify operation of functional parts. Refer to Verifying the correct operation on page 81. • The following commands can be useful to establish an operational baseline for the device. Refer to the Ruckus FastIron Command Reference guide for more information on these commands: – – – – – – – – – – Back up the configuration. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Completed show chassis show version show cpu show flash show files show run show boot-preference show configuration show running-config show logging Use the write memory command to replace the startup configuration with the running configuration. Refer to Backing up the running configuration on page 81 for more information. 25 Preparing for the Installation Shipping carton contents Shipping carton contents When unpacking the device, verify that the contents of the shipping carton is complete. Save the shipping carton and packaging in the event you need to return the shipment. • The Ruckus ICX 7150 device • An accessory kit containing the following items: – – – – – – – – 26 Rack mounting kit containing two L-shaped mounting brackets and two sets of eight sink-head screws (included only with 24-port and 48-port models) Wall mounting kit containing two wall-mount screws and two plastic anchors (included only with ICX 7150-C12P) Two-post rack kit containing four rack-mounting screws and four cage nuts (included only with 24-port and 48-port models) Four rubber feet One AC power cord, shielded (US only) One power cord retainer clip China-RoHS Hazardous/Toxic Substance statement Read Me First document Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device • • • • • • • • • • • • • Mounting options.................................................................................................................................................... 27 Precautions specific to mounting.............................................................................................................................27 Mounting on a desktop or flat surface..................................................................................................................... 28 Mounting the compact device with a magnet.......................................................................................................... 30 Mounting the compact device under a fixed surface................................................................................................ 36 Mounting the compact device directly on a wall.......................................................................................................39 Mounting on a wall using the wall mount brackets................................................................................................... 43 Mounting on a two-post rack.................................................................................................................................. 48 Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295)...................................................53 Time and items required.......................................................................................................................................... 54 Parts list.................................................................................................................................................................. 54 Flush-front mounting the device in the rack............................................................................................................. 55 Flush-rear (recessed) mounting the device in the rack..............................................................................................62 Mounting options You can install the device in several ways: • As a standalone unit on a flat surface, for example, a table top. Use the rubber feet included with the shipment to secure the device on the surface. No other equipment is required for desktop installation. • Only ICX 7150-C12P compact device: – – – As a standalone unit using a magnet (ICX6400-C12-MGNT) on a rack or on any surface that is magnetic such as a metal desk or cabinet. As a standalone unit under a fixed surface, under a desk, or under a shelf using the wall / under desk mount kit (ICX7000C12-WMK) or two-post rack mount kit (ICX7000-C12-RMK ) . As a standalone unit directly on a wall using two screws. • As a standalone unit on a wall using the wall mounting brackets included with the shipment to secure the device on the wall. No other equipment is required for wall mount installation. • In a two-post Telco rack: You will need a Universal Two-Post Rack Kit (ICX7000-RMK or ICX7000-C12-RMK ) to install in a twopost telecommunications (Telco) rack. • In a four-post EIA rack: You will need a Universal Four-Post Rack Kit (XBR-R000295) to install devices in EIA racks that are between L-13.7 to 81.28 cm deep (L-5.0 to 32.0 in.), where L is the chassis depth. Precautions specific to mounting The following precautions specifically apply to mounting the device. DANGER Use safe lifting practices when moving the product. DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 27 Mounting the Device Mounting on a desktop or flat surface DANGER Mount the devices you install in a rack as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above. DANGER This equipment is suitable for mounting on concrete or other noncombustible surfaces only. CAUTION Make sure the airflow around the front, and back of the device is not restricted. CAUTION Never leave tools inside the chassis. CAUTION Use the screws specified in the procedure. Using longer screws can damage the device. CAUTION The device must be turned off and disconnected from the fabric during this procedure. Mounting on a desktop or flat surface Complete the following steps to install the device on a desktop or other flat surface. The device you are installing might look different than the one in the following illustration. NOTE The hardware device illustrated in this procedure is only for reference and may not depict the actual device that you are installing. 28 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a desktop or flat surface FIGURE 13 Attaching the adhesive feet on a compact device Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 29 Mounting the Device Mounting the compact device with a magnet FIGURE 14 Attaching the adhesive feet on a 24-port or 48-port device 1. Attach the four adhesive feet to the bottom of the device. If installing multiple devices, attach the adhesive feet to each device. 2. Set the device on a flat desktop, table, or shelf near an AC power source. Make sure that adequate ventilation is provided for the system. A 7.62 cm (3 in.) clearance is recommended on each side. 3. If installing multiple devices, place each device squarely on top of the one below. If you have both compact devices and regular devices, place the regular devices at the bottom. 4. Power on the system. Mounting the compact device with a magnet CAUTION Ensure that adequate ventilation is provided for the system. A 3 cm clearance is recommended above the device and 8 cm clearance is recommended on each side. CAUTION When magnet mounting a switch, do not install it in a position where it can easily become unstable and fall, causing injury or damage to the switch. Use the magnet-mount kit to mount the device on a metal wall or a metal surface, including underneath a metal desk. The magnet-mount kit is available for order separately from the device and consists of a single magnet sheet. 30 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device with a magnet Before mounting the device to a metal surface using the magnet sheet, ensure that the following requirements are met: • The magnet sheet is attached to the bottom panel of the device. Refer to Attaching the magnet sheet to the device on page 31. • Ensure that the device is not installed more than 110 mm. above the floor. Note the following important installation considerations before installing the device on a metal surface using the magnet mount: • The strength of the magnet will vary depending on the surface it is used on. • The magnet’s force might weaken over time. Check the strength of the magnet regularly for about one year. Move the device up and down and confirm the magnet strength. When adequate ventilation is provided and the magnet is attached to the device, you can securely mount the device in the following locations: • A metal wall or metal surface. Refer to Mounting the device on a metal surface or metal wall on page 32. • Underneath a metal desktop. Refer to Mounting the device under a metal desk on page 34. Attaching the magnet sheet to the device Before mounting the device to a metal surface, place the logo side of the magnet sheet (displaying the Brocade logo) squarely against the bottom panel of the device to attach the device to the magnet sheet. CAUTION The magnet sheet can only be placed against the bottom panel of the device. Do not attempt to attach the magnet sheet to any other panels on the device. CAUTION Before mounting the device using the magnet sheet, make sure the rubber feet are not installed on the device to ensure that the magnet sheet holds on to the device strongly and does not detach. If the rubber feet are already installed, remove them first before attaching the magnet sheet. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 31 Mounting the Device Mounting the compact device with a magnet FIGURE 15 Attaching the logo side of the magnet sheet to the bottom panel of the compact device Mounting the device on a metal surface or metal wall CAUTION Do not mount the device on a surface with the top panel facing downward. Mount the device only on a vertical metal surface with the front panel port-side facing downward. CAUTION Ensure that the metal surface is flat and the texture is smooth to hold the device strongly. Check for other conditions that might impede secure magnetic mount. Complete the following steps to securely mount a compact device on a metal surface or metal wall: 1. 32 Ensure that the magnet sheet is attached to the bottom panel of the device. Refer to Attaching the magnet sheet to the device on page 31. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device with a magnet 2. Place the magnet sheet (with the logo side now attached to the bottom panel of the device) against the metal surface or metal wall. FIGURE 16 Mounting a compact device to a metal surface using the magnet mount Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 33 Mounting the Device Mounting the compact device with a magnet FIGURE 17 A compact device mounted on a metal surface with ports down Mounting the device under a metal desk NOTE Do not mount the device directly underneath a desktop surface with the top panel facing downward. Mount the device only on the vertical metal surface of the desk with the front panel ports side facing downward. Complete the following steps to securely mount a compact device under a metal desktop: 1. 34 Ensure that the magnet sheet is attached to the bottom panel of the device. Refer to Attaching the magnet sheet to the device on page 31. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device with a magnet 2. Place the bottom panel of the device with the magnet sheet attached under the metal desk, against the side of the device. Ensure that the front panel (port side) of the device is facing downward. FIGURE 18 Mounting a compact device underneath a metal desktop using the magnet mount 1. Magnet Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 2. Metal desk 35 Mounting the Device Mounting the compact device under a fixed surface FIGURE 19 A compact device securely mounted underneath a metal desk with the port side facing down Mounting the compact device under a fixed surface Use the following items to mount the device under a fixed surface such as under a desk, or under a shelf. 36 • #2 Phillips screwdriver • Hammer • Drill • Mounting anchors • Wall / under desk mount kit (ICX7000-C12-WMK - short brackets) or two-post rack mount kit (ICX7000-C12-RMK - long brackets) • Mounting screws Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device under a fixed surface DANGER When mounting the device under a fixed surface, under a desk, or under a shelf, mount the device with the bottom panel down and in a place where there is not much foot traffic. The fixed surface must be strong enough to withstand the weight of the device such that the device or the surface does not fall down. CAUTION When mounting the device under a fixed surface, under a desk, or under a shelf, use the long brackets to provide adequate ventilation and not exceed the operating temperature. CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 35°C (95°F). Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 37 Mounting the Device Mounting the compact device under a fixed surface Complete the following steps to mount the device under a fixed surface. 1. Using a Phillips screwdriver, attach the mounting brackets to the diagonally opposite sides of the device using two #6-32 sinkhead screws on each side. FIGURE 20 Mounting a compact device under a fixed surface with short brackets (ICX7000-C12-WMK) 38 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device directly on a wall FIGURE 21 Mounting a compact device under a fixed surface with long brackets (ICX7000-C12-RMK) 2. Drill two holes under the fixed surface or desk where you want to mount the device. 3. Hammer the mounting anchors into the two holes. 4. With the bottom panel of the device facing down, use the #2 Phillips screwdriver to secure the two mounting screws into the mounting anchors. Mounting the compact device directly on a wall Use the following items to wall mount the device directly to a wall: • #2 Phillips screwdriver • Hammer • Drill • Wall mount anchors • Wall mount screws • Wall Mount Holes Location template • Tape NOTE When mounting the device on a wall, mount the device with the port side down. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 39 Mounting the Device Mounting the compact device directly on a wall Complete the following steps to mount the device directly to a wall. 40 1. Use tape to place the Wall Mount Holes Location template against the wall, in the same position that you plan to place the device against the wall. The Wall Mount Holes Location template serves as a guide to drilling the screws and wall-mount anchors into the correct location on the wall in order to place the device in the desired location. 2. Using the Wall Mount Holes Location template as a guide, drill two holes in the wall where you want to mount the device. 3. Hammer the wall-mount anchors into the two holes. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting the compact device directly on a wall 4. Use the #2 Phillips screwdriver to secure the two wall-mount screws into the wall-mount anchors. Leave a gap of 4.0 to 4.5 mm between the screw head and the wall. FIGURE 22 Preparing to wall mount the device 1. Drilled holes in wall 2. Wall-mount anchors 3. Wall-mount screws 4. 4.0-4.5 mm space between screw head and wall Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 41 Mounting the Device Mounting the compact device directly on a wall 5. With the port side of the device facing down, aim the mounting holes on the bottom panel of the device towards the wallmounting screws on the wall and hang the device securely against the wall, so that the wall-mount screws are inserted into the mounting holes. FIGURE 23 Wall mounting a compact device - View of rear panel 42 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a wall using the wall mount brackets FIGURE 24 Wall mounting a compact device - View of the top panel Mounting on a wall using the wall mount brackets NOTE You need a #2 Phillips screwdriver, a hammer, and a drill for wall mount installation. NOTE Mount the devices that have fans such that there is enough space for ventilation on the air-intake and air-exhaust sides to maintain the ambient operating temperature. DANGER This equipment is suitable for mounting on concrete or other noncombustible surfaces only. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 43 Mounting the Device Mounting on a wall using the wall mount brackets NOTE The hardware device illustrated in this procedure is only for reference and may not depict the actual device that you are installing. Complete the following steps to mount the device to a wall. 1. 44 Attach the four adhesive feet to the bottom of the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a wall using the wall mount brackets 2. Using a Phillips screwdriver, attach the wall mount brackets to the sides of the device using four #6-32 sink-head screws on each side. FIGURE 25 Attaching the wall mount brackets to a 24-port device Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 45 Mounting the Device Mounting on a wall using the wall mount brackets FIGURE 26 Attaching the wall mount brackets to a 48-port device 46 3. Drill two holes on the wall where you want to mount the device. 4. Hammer two wall mount anchors into the holes on the wall. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a wall using the wall mount brackets 5. Use the two wall mount screws to fasten the device to the wall mount anchors. FIGURE 27 Wall mounting a 24-port device with port-side up 1. Drilled holes 2. Wall mount anchors Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 3. Wall mount screws 47 Mounting the Device Mounting on a two-post rack FIGURE 28 Wall mounting a 48-port device with port-side down NOTE Brocade recommends that you install the 24P, 48P, and 48PF models with the port-side down to maintain the ambient temperature. Mounting on a two-post rack The devices use stationary mounting when mounted in a rack. DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. 48 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a two-post rack CAUTION Ensure that adequate ventilation and airflow is provided for the system. A 4.5 cm (1.77 in) clearance is recommended above and below the device and 8 cm (3.15 in) clearance is recommended on each side. NOTE You need a #2 Phillips screwdriver for rack mount installation. NOTE The ICX 7150-C12P compact device requires the ICX7000-C12-RMK rack mount kit which is optionally orderable. Complete the following steps to mount devices in a rack. 1. Remove the rack mounting kit from the shipping carton. The kit contains two L-shaped mounting brackets and six sink-head screws. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 49 Mounting the Device Mounting on a two-post rack 2. Using a Phillips screwdriver, attach the mounting brackets to the sides of the device using six sink-head screws. FIGURE 29 Attaching the mounting brackets for a compact device 50 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Mounting on a two-post rack FIGURE 30 Attaching the rack mounting brackets for 24-port and 48-port devices 3. Remove the two-post rack kit from the shipping carton. The kit contains four rack-mounting screws and four cage nuts. 4. Insert the cage nuts in the two-post rack where you want to mount the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 51 Mounting the Device Mounting on a two-post rack 5. Using a Phillips screwdriver, mount the device in a two-post rack using four rack-mounting screws. FIGURE 31 Installing a compact device in a two-post rack 1. 52 Rack-mounting screws 2. Cage nuts Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295) FIGURE 32 Installing a 24-port or 48-port device in a two-post rack 6. 1. Rack-mounting screws 2. Cage nuts If installing multiple devices, mount them in the rack, one below the other with the heaviest device at the bottom and lightest device on the top. Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295) Use the following instructions to install a 1U, 1.5U, or 2U device in a 19-in. (48.3 cm) EIA rack using the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-R000295). Any updates to these instructions will be added to the hardware installation guide for your product. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 53 Mounting the Device Time and items required The device can be installed so that the port side is either flush with the front posts or recessed with the non-port side flush with the rear posts. A recessed position allows a more gradual bend in the fiber-optic cables connected to the device and less interference in the aisle at the front of the rack. NOTE Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the rack. Time and items required Allow 15 to 30 minutes to complete this procedure. Note the following requirements to ensure correct installation and operation. The following items are required to install the device using the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks: • #2 Phillips torque screwdriver • 1/4-inch slotted-blade torque screwdriver Parts list The following parts are provided with the 1U, 1.5U, and 2U Universal Kit for Four Post Racks Installation (XBR-R000295). 54 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-front mounting the device in the rack FIGURE 33 Rack kit parts 1. Front brackets (2) 6. Screw, 8-32 x 5/16-in., panhead Phillips (8) 2. Bracket extensions (2) 7. Screw, 8-32 x 5/16-in., flathead Phillips (16) 3. Rear brackets, short (2) 8. Screw, 6-32 x 1/4-in., panhead Phillips (8) 4. Rear brackets, medium (2) 9. Screw, 10-32 x 5/8-in., panhead Phillips (8) 5. Rear brackets, long (2) 10. Retainer nut, 10-32 (8) Ensure that the items listed and illustrated are included in the kit. Note that not all parts may be used with certain installations depending on the device type. CAUTION Use the screws specified in the procedure. Using longer screws can damage the device. Flush-front mounting the device in the rack CAUTION The device must be turned off and disconnected from the fabric during this procedure. NOTE Illustrations in these rack installation procedures are for reference only and may not show the actual device that you are installing. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 55 Mounting the Device Flush-front mounting the device in the rack Complete the following tasks to install the device in a four-post rack: 1. Attaching the front brackets on page 56 2. Attaching the bracket extensions to the device on page 57 3. Installing the device in the rack on page 58 4. Attaching the rear brackets to the extensions on page 59 5. Attaching the rear brackets to the rack posts on page 61 Attaching the front brackets Complete the following steps to attach the front brackets to the device. 56 1. Position the right front bracket with the flat side against the right side of the device at the front of the device, as shown in Figure 34. 2. Insert four 8-32 x 5/16-in. flathead screws through the vertically aligned holes in the bracket and then into the holes on the side of the device. Use the upper and lower screw holes, leaving the center holes empty. 3. Repeat Step 1 and Step 2 to attach the left front bracket to the left side of the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-front mounting the device in the rack 4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). FIGURE 34 Attaching the front brackets 1. Brocade device 2. Front brackets 3. Screws, 8-32 x 5/16-in., flathead Phillips Attaching the bracket extensions to the device Complete the following steps to attach the extension brackets to the device. 1. Position the right bracket extension along the side of the device as shown in Figure 35. 2. Insert four 8-32 x 5/16-in. flathead screws through the vertically aligned holes in the bracket extension and then into the holes on the side of the device. Use the upper and lower screw holes, leaving the center holes empty. 3. Repeat step 1 and step 2 to attach the left bracket extension to the left side of the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 57 Mounting the Device Flush-front mounting the device in the rack 4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). FIGURE 35 Attaching the bracket extensions to the device 1. Bracket extensions 2. Screws, 8-32 x 5/16-in., flathead Phillips Installing the device in the rack Complete the following steps to install the device in the rack. 58 1. Position the device in the rack, as shown in Figure 36, providing temporary support under the device until the rail kit is secured to the rack. 2. Attach the right front bracket to the right front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. 3. Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-front mounting the device in the rack 4. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). FIGURE 36 Positioning the device in the rack 1. Screws, 10-32 x 5/8-in., panhead Phillips 2. Retainer nuts, 10-32 Attaching the rear brackets to the extensions Complete the following steps to attach the rear brackets to the extensions. There are short, medium, and long rear brackets that you can use for this step. Choose the correct bracket for the depth of your rack. 1. Select the proper length rear bracket for your rack depth. 2. Slide the right rear bracket onto the right extension, as shown in Figure 37. The short rear brackets are shown. Use the first and third vertical pairs of holes for the screws. Refer to Figure 38 for the positioning of the medium or long brackets and screws. 3. Attach the brackets using four 6-32 x 1/4-in. panhead screws. 4. Repeat Step 2 and Step 3 to attach the left rear bracket to the left extension. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 59 Mounting the Device Flush-front mounting the device in the rack 5. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). FIGURE 37 Attaching the short rear brackets to the extensions 1. Rear brackets 2. Screws, 6-32 x 1/4-in., panhead Phillips FIGURE 38 Attaching the medium or long rear brackets to the extensions 60 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-front mounting the device in the rack 1. Rear bracket, medium or long 2. Screws, 6-32 x 1/4-in., panhead Phillips Attaching the rear brackets to the rack posts Complete the following steps to attach the rear brackets to the rack posts. 1. Attach the right rear bracket to the right rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts, as shown in Figure 39. Use the upper and lower holes in the bracket. 2. Attach the left rear bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. 3. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). FIGURE 39 Attaching the rear brackets to the rack posts 1. Screws, 10-32 x 5/8-in., panhead Phillips Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 2. Retainer nuts, 10-32 61 Mounting the Device Flush-rear (recessed) mounting the device in the rack Flush-rear (recessed) mounting the device in the rack The flush-rear (recessed) mounting is similar to the flush-front mounting except that the brackets are reversed on the device. CAUTION The device must be turned off and disconnected from the fabric during this procedure. NOTE Illustrations used in these rack installation procedures are for reference only and may not show the actual device that you are installing. Complete the following tasks to install the device in a four-post rack: 1. Attaching the front brackets to the rear of the device on page 62 2. Attaching the bracket extensions to the front of the device on page 63 3. Installing the device in the rack on page 64 4. Attaching the rear brackets to the bracket extensions at the front of the device on page 65 5. Attaching the rear brackets to the front rack posts on page 67 Attaching the front brackets to the rear of the device NOTE In this installation, the brackets are named as listed in the parts list even though the installation of the brackets is reversed from the flush-front installation. Complete the following steps to attach the front brackets to the rear of the device. 62 1. Position the right front bracket with the flat side against the right rear side of the device, as shown in Figure 40. 2. Insert four 8-32 x 5/16-in. flathead screws through the vertically aligned holes in the bracket and then into the holes on the side of the device. Use the upper and lower screw holes, leaving the center holes empty. 3. Repeat Step 1 and Step 2 to attach the left front bracket to the left rear side of the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-rear (recessed) mounting the device in the rack 4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). FIGURE 40 Attaching the front brackets to the rear of the device 1. Brocade device 2. Front brackets 3. Screws, 8-32 x 5/16-in., flathead Phillips Attaching the bracket extensions to the front of the device Complete the following steps to attach the bracket extensions to the front of the device. 1. Position the right bracket extension along the side of the device as shown in Figure 41. 2. Insert four 8-32 x 5/16-in. flathead screws through the vertically aligned holes in the bracket extension and then into the holes on the side of the device. Use the upper and lower screw holes, leaving the center holes empty. 3. Repeat step 1 and step 2 to attach the left front bracket extension to the left side of the device. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 63 Mounting the Device Flush-rear (recessed) mounting the device in the rack 4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). FIGURE 41 Attaching the bracket extensions to the device 1. Bracket extensions 2. Screws, 8-32 x 5/16-in., flathead Phillips Installing the device in the rack Complete the following steps to install the device in the rack. 64 1. Position the device in the rack, as shown in Figure 42, providing temporary support under the device until the rail kit is secured to the rack. 2. Attach the right front bracket to the right rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. 3. Attach the left front bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-rear (recessed) mounting the device in the rack 4. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). FIGURE 42 Positioning the device in the rack 1. Screws, 10-32 x 5/8-in., panhead Phillips 2. Retainer nuts, 10-32 Attaching the rear brackets to the bracket extensions at the front of the device Complete the following steps to attach the rear brackets to the bracket extensions. There are short, medium, and long front brackets that you can use for this step. 1. Select the proper length rear bracket for your rack depth. 2. Slide the right rear bracket onto the right extension, as shown in Figure 43. The short rear brackets are shown. Use the first and third vertical pairs of holes for the screws. Refer to Figure 44 for the positioning of the medium or long brackets and screws. 3. Attach the brackets using four 6-32 x 1/4-in. panhead screws. 4. Repeat Step 2 and Step 3 to attach the left rear bracket to the left extension. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 65 Mounting the Device Flush-rear (recessed) mounting the device in the rack 5. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). FIGURE 43 Attaching the short rear brackets to the extensions at the front of the device 1. 66 Rear brackets, short 2. Screws, 6-32 x 1/4-in., panhead Phillips Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Mounting the Device Flush-rear (recessed) mounting the device in the rack FIGURE 44 Attaching the medium or long rear brackets to the extensions 1. Rear bracket, medium or long 2. Screws, 6-32 x 1/4-in., panhead Phillips Attaching the rear brackets to the front rack posts Complete the following steps to attach the rear brackets to the front rack posts. 1. Attach the right rear bracket to the right front rack post using two 10-32 x 5/8-in. screws and two retainer nuts, as shown in Figure 45. Use the upper and lower holes in the bracket. 2. Attach the left rear bracket to the left front rack post using two 10-32 x 5/8-in. screws and two retainer nuts. Use the upper and lower holes in the bracket. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 67 Mounting the Device Flush-rear (recessed) mounting the device in the rack 3. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). FIGURE 45 Attaching the rear brackets to the front rack posts 1. 68 Screws, 10-32 x 5/8-in., panhead Phillips 2. Retainer nuts, 10-32 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Connecting ICX 7150 Devices in a Stack • • • Stacking configuration requirements........................................................................................................................69 ICX 7150 stacking ports.......................................................................................................................................... 69 ICX 7150 stacking topologies.................................................................................................................................. 71 Stacking configuration requirements Before configuring a traditional stack using the CLI, physically connect the devices with stacking cables. For more information on configuring a stack, refer to the FastIron Stacking Configuration Guide. ICX 7150 stacking ports Depending on the model, up to eight SFP+ ports on the front panel of the ICX 7150 device support stacking. The ports can also be used as uplink (data) ports. The following figures show the location and numbering for stacking ports. The numbering for the ports is in three-tuple format (x/y/z) and refers to StackID/Slot/Port. ICX 7150-C12P devices have two stacking ports on the front panel as shown in the following figure. FIGURE 46 ICX 7150-C12P stacking ports ICX 7150-24 and ICX 7150-24P devices have four stacking ports on the front panel as shown in the following figure. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 69 Connecting ICX 7150 Devices in a Stack ICX 7150 stacking ports FIGURE 47 ICX 7150 stacking port location on 24-port and some 48-port models ICX 7150-48, ICX 7150-48P, and ICX 7150-48PF devices have four stacking ports in the same location on the front panel as ICX 7150 24port models. The exception among 48-port models is the ICX 7150-48PZ, which has eight SPF+ ports on the front panel as shown in the following figure. Four of these ports, ports 1/2/1 through 1/2/4, can be used as stacking or data uplink ports. The remaining four, 1/2/5 through 1/2/8, can be used only as data uplink ports. FIGURE 48 ICX 7150-48ZP stacking ports 70 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Connecting ICX 7150 Devices in a Stack ICX 7150 stacking topologies ICX 7150 stacking topologies Both linear and ring topologies are supported in a traditional stack. In a linear stack topology, a connection between each switch carries two-way communications across the stack. The physical connection between the devices can use one port (stacked-port) or two ports (stacked-trunk) per trunk. In ring stack topology, an extra connection between the logical first and last devices forms a "ring" or "closed-loop." The closed-loop connection provides a redundant path for the stack link, so if one link fails, stack communications can be maintained. You can connect stacking units using one port per trunk or both ports in a trunk. For maximum bandwidth and link redundancy, use both ports per trunk. Linear and ring topologies are depicted for different ICX 7150 models in the following figures. NOTE Port numbers shown are specific to each physical unit; that is, the unit ID is 1, in the three-tuple StackID/slot/port notation. Assuming the stack in the following figure is numbered from the bottom when it is configured, the connected stacking port for the bottom stack (stack unit 1) would be identified as port 1/3/2, and the connected port in the middle stack unit (stack unit 2) would be identified as 2/3/1. Port 2/3/2 in the middle stack unit would be shown as connecting to port 3/3/1 in the top unit (stack unit 3). NOTE The Secure-setup utility used to discover and configure the stack assigns each unit a different stack ID. You can override the automatic selection if you choose. Refer to the FastIron Stacking Configuration Guide for more information. The following figures show examples of supported stacking topologies for the ICX 7150-C12P. FIGURE 49 ICX 7150-C12P linear stack Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 71 Connecting ICX 7150 Devices in a Stack ICX 7150 stacking topologies FIGURE 50 ICX 7150-C12P ring topology The following figures show examples of supported topologies for ICX 7150 24-port models. FIGURE 51 ICX 7150 24-port model, linear stack 72 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Connecting ICX 7150 Devices in a Stack ICX 7150 stacking topologies FIGURE 52 ICX 7150 24-port model, ring stack The following figures show examples of supported topologies for the ICX 7150-48ZP. FIGURE 53 ICX7150-48ZP linear stack Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 73 Connecting ICX 7150 Devices in a Stack ICX 7150 stacking topologies FIGURE 54 ICX 7150-48ZP ring stack 74 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Initial Setup and Verification • • • • • • • • • • Items required......................................................................................................................................................... 75 Providing power to the device................................................................................................................................. 75 Establishing a first-time connection to the console port........................................................................................... 76 Configuring an IP address for the device................................................................................................................. 79 Customizing the host name and chassis name ....................................................................................................... 79 Setting the date and time........................................................................................................................................ 80 Establishing a connection to the out-of-band management port..............................................................................80 Getting in-band access........................................................................................................................................... 81 Verifying the correct operation................................................................................................................................. 81 Backing up the running configuration...................................................................................................................... 81 Items required The following items are required for initial setup and verification of the device: • The device, mounted and installed with the required power supply, fan assemblies, transceivers, and cables • A workstation computer with a terminal emulator application installed, such as HyperTerminal for Windows • An unused IP address with corresponding subnet mask and gateway address • An USB console cable with Type-C connector (Type-C USB cable not included with the device) • A serial console cable with an RJ-45 connector (RJ-45 console cable not included with the device) • An Ethernet cable • Access to a TFTP server or USB removable media for backing up (uploading) or downloading the device configuration (optional) Providing power to the device Perform the following steps to provide power to the device. 1. Remove the power cord and the power cord retainer clip from the shipping carton container. 2. Install the power cord retainer clip to the power supply inlet on the device. 3. Connect the power cord to the power supply inlet on the device. Ensure that the power cords have a minimum service loop of 6 inches available and are routed properly to avoid stress. 4. Insert the power cord plug to power sources on separate circuits if there is more than one power cord for a single device in order to protect against power failure. 5. If applicable, power on the power sources by flipping the switches to the on position. The SYST LED displays amber until poweron self-test (POST) is complete and then starts blinking green until the device is completely up. The device usually requires several minutes to boot and complete POST. NOTE Power is supplied to the device as soon as the first power supply is connected and turned on. If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 75 Initial Setup and Verification Establishing a first-time connection to the console port 6. After POST is complete, verify that the switch power and switch status LEDs are green. NOTE Power Supply LED should always display solid green to ensure a working power supply. If the LED is amber, it indicates a faulty PSU. For more information about how to interpret POST, BOOT, and diagnostics tests, refer to Monitoring the Device on page 91. Establishing a first-time connection to the console port You can use either the USB Type-C console port or the RJ-45 serial console port to establish the first time connection to the device. The console port allows you to configure and manage the device using a third-party terminal emulation application from a workstation that is directly connected to the port using a standard USB Type-C cable or RJ-45 serial cable. Perform the following steps to log in to the device for the first time through the console connection. 1. 2. Do one of the following: • Connect a standard USB cable to the USB Type-C console connector on the device and to a USB port on the workstation. To connect the USB Type-C console port on the device to a USB port on the workstation, you need a standard USB cable that has a USB Type-C connector on one end and a USB connector on the other end that matches the USB port on your workstation. • Connect a standard RJ-45 cable to the RJ-45 serial console connector on the device and to a USB port on the workstation. To connect the RJ-45 serial console port on the device to a USB port on the workstation, you need a standard RJ-45 cable that has a RJ-45 connector on one end and a USB connector on the other end that matches the USB port on your workstation. Allow the workstation to automatically discover and configure the newly found USB device. NOTE If the workstation is unable to automatically discover and configure the newly found USB device, you can manually download the necessary device drivers for Windows, MacOS, and Linux from the following website: http:// my.brocade.com 76 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Initial Setup and Verification Establishing a first-time connection to the console port 3. Open a terminal emulator application such as HyperTerminal on a Windows PC, or TERM, TIP, or Kermit in a UNIX environment, and configure the sessions parameters as follows: • In a Windows environment, use the following values: Parameter Value Baud: Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None NOTE Flow control is not supported on the console connection when attached to a remote terminal and must be disabled on the customer-side remote terminal server in addition to the host-side clients. • In a UNIX environment using TIP, enter the following string at the prompt: tip /dev/ttyb -9600. If ttyb is already in use, use ttya instead and enter the following string at the prompt: tip /dev/ttya -9600 4. When the terminal emulator application stops reporting information, press Enter to display the device prompt. Depending on the device you purchased, and the code (Layer 2 or Layer 3) loaded on your system, the device prompt is displayed accordingly. device> When the device prompt is displayed, you are connected to the device. You can customize the prompt by changing the device name. If you do not see this prompt, make sure the cable is securely connected to your workstation and to the device and check the settings in your terminal emulation program. In addition to the previously configured session settings, make sure the terminal emulation session is running on the same serial port you attached to the device. The device CLI prompt has the following access levels: • User EXEC: This is the level you enter when you first start a CLI session. At this level, you can view some system information but you cannot configure system or port parameters. • Privileged EXEC: This level is also called the Enable level and can be secured by a password. You can perform tasks such as managing files on the flash module, saving the system configuration to flash, and clearing caches at this level. • CONFIG: The configuration level. This level allows you to configure the system IP address and configure switching and routing features. To access the CONFIG mode, you must already be logged in to the privileged EXEC level. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 77 Initial Setup and Verification Establishing a first-time connection to the console port 5. At the opening CLI prompt, enter the following command to change to the Privileged EXEC mode: device> enable device# By default, the CLI is not protected by passwords. To secure CLI access, Brocade strongly recommends assigning passwords. You can set the following levels of passwords: • Super User: Allows complete read-and-write access to the system. This is generally for system administrators and is the only password level that allows you to configure other passwords. NOTE You must set a Super User password before you can set other types of passwords. You can also assign other passwords using Brocade Network Advisor after an enable password has been configured for a Super User on the device using the CLI. • Port Configuration: Allows read-and-write access to specific ports but not for global (system-wide) parameters. • Read-Only: Allows access to the privileged EXEC mode and CONFIG mode but only with read access. NOTE Passwords can be up to 32 characters long. They must begin with an alphabetic character. They can include numeric characters, the period (.), and the underscore (_) only. Passwords are case-sensitive, and they are not displayed when you enter them on the command line. 6. Access the configuration mode of the CLI by entering the following command: device# configure terminal device(config)# 7. Enter the following command to set the Super User password: device(config)# enable super-user-password joe NOTE Make sure to write down the new passwords and keep the information in a secure location. 8. Enter the following commands to set the port configuration and read-only passwords. device(config)# enable port-config-password john device(config)# enable read-only-password sam Recovering from a lost password If a password has been configured for the device but the password has been lost, you can regain Super User access to the device using the following procedure. Recovery from a lost password requires direct access to the serial port and a system reset. 78 1. Start a CLI session over the serial interface to the Brocade device. 2. Reboot the device. 3. While the system is booting, before the initial system prompt appears, enter b to enter the boot monitor mode. 4. Enter no password. (You cannot abbreviate this command.) 5. Enter boot. This command causes the device to bypass the system password check. 6. After the console prompt reappears, assign a new password. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Initial Setup and Verification Customizing the host name and chassis name Configuring an IP address for the device You must configure at least one IP address using the serial connection to the CLI before you can manage the device using the other management interfaces. You can use the classical IP network masks (Class A, B, and C subnet masks, and so on) or Classless Interdomain Routing (CIDR) network prefix masks. • To enter a classical IP network mask, enter the mask in IP address format. For example, enter "10.157.22.99 255.255.255.0" for an IP address with a Class C subnet mask. • To enter a prefix number for a network mask, enter a forward slash (/) and the number of bits in the mask immediately after the IP address. For example, enter "10.157.22.99/24" for an IP address that has a network mask with 24 significant ("mask") bits. 1. At the opening CLI prompt, enter the following commands. device> enable device# erase startup-config device# configure terminal NOTE Use the erase startup-config command only for new systems. If you enter this command on a system you have already configured, the command erases the configuration. If you accidentally erase the configuration on a configured system, enter the write memory command to save the running configuration to the startup-config file. 2. Enter the following commands to assign an IP address for a device running Layer 2 software. device(config)# ip address 10.22.3.44 255.255.255.0 device(config)# ip default-gateway 10.22.3.1 device(config)# write memory NOTE You do not need to assign a default gateway address for single subnet networks. Enter the following commands to add an IP address and mask to a router port on a device running Layer 3 software. device(config)# interface ethernet 1 device(config)# ip address 10.22.3.44 255.255.255.0 device(config)# write memory NOTE Before attaching any equipment to a device running Layer 3 software, you must assign an interface IP address to the subnet on which the device will be located. You must use the serial connection to assign the first IP address. For subsequent addresses, you can use the CLI through Telnet. 3. Assign an interface IP address to the out-of-band management Ethernet port. device(config)# interface management 1 device(config)# ip address 10.22.3.45 255.255.255.0 device(config)# write memory The management port number is always 1. Customizing the host name and chassis name Changing the host name, contact, and location is important for distinguishing and identifying the device uniquely and for accurate tracking of logs and errors. The messages that appear in the log are labeled with the chassis name, which makes tracking the errors much easier. Specify an easily understandable and meaningful host name and chassis name. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 79 Initial Setup and Verification Setting the date and time Perform the following steps to change the host name and then the chassis name. 1. Customize the host name, contact, and location using the following commands. When you configure a host name, the name replaces the default system name in the device CLI prompt. device(config)# hostname sj_device1 sj_device1(config)# snmp-server contact Support Services sj_device1(config)# snmp-server location San Jose sj_device1(config)# end sj_device1# write memory The name, contact, and location each can be up to 255 alphanumeric characters. The text strings can contain blanks. The SNMP text strings do not require quotation marks when they contain blanks but the host name does. 2. Change the chassis name by using the chassis name command. device(config)# chassis name SJ001 sj_device1(config)# end sj_device1# write memory The chassis name command does not change the device CLI prompt. Instead, the command assigns an administrative ID to the device. Setting the date and time Use the following command to set the current date and time for the device. device# clock set hh:mm:ss Current Time device# clock set 10:05:45 mm-dd-yy/yyyy Current Date device# clock set 10:05:45 12-01-16 Establishing a connection to the out-of-band management port The out-of-band management interface is an RJ-45 Ethernet port that allows you to access, configure, and manage the device from the network. Perform the following steps to establish a connection to the device using the out-of-band Ethernet management port. 1. Remove the plug from the RJ-45 management port. 2. Connect an Ethernet cable to the device RJ-45 management port and to the workstation or to an Ethernet network containing the workstation. NOTE At this point, the device can be accessed remotely using the CLI or Brocade Network Advisor. Ensure that the device is not being modified from any other connections. The Ethernet management port also supports auto-MDI and auto-MDIX. 80 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Initial Setup and Verification Backing up the running configuration Getting in-band access You can access the management agent in the device from anywhere within the attached network using Telnet or other network management software. However, you must first configure the device with a valid IP address, subnet mask, and default gateway. If you have trouble establishing a link to the management agent, check to see if you have a valid network connection. Then verify that you entered the correct IP address. Also, be sure the port through which you are connecting to the device has not been disabled. If it has not been disabled, then check the network cabling that runs between your remote location and the device. Verifying the correct operation Check the LEDs to verify operation of functional parts. The following commands can be useful to establish an operational baseline for the device. Refer to the Ruckus FastIron Command Reference for more information on these commands. • show chassis • show version • show cpu • show flash • show files • show run • show boot-preference • show configuration • show running-config • show logging Backing up the running configuration Use the write memory command to replace the startup configuration with the running configuration every time you make changes to the device configuration. To back up the device configuration to an external TFTP server, use the copy running-config tftp command. device# copy running-config tftp 2001:DB8:e0ff:7837::3 newrun.cfg This command example copies the running configuration to a TFTP server with the IPv6 address of 2001:DB8:e0ff:7837::3 and names the file on the TFTP server newrun.cfg. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 81 82 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Installing Transceivers and Cables • • • • • • • • Time and items required.......................................................................................................................................... 83 Precautions specific to transceivers and cables....................................................................................................... 83 Managing cables..................................................................................................................................................... 84 Installing the Ethernet RJ-45 cables.........................................................................................................................84 Cleaning the fiber-optic connectors......................................................................................................................... 86 Installing a new fiber-optic transceiver..................................................................................................................... 86 Cabling a fiber-optic transceiver...............................................................................................................................87 Replacing a fiber-optic transceiver........................................................................................................................... 88 Time and items required The installation or replacement procedure for one transceiver takes less than five minutes. Ensure that the following items are available: • Required number of compatible power cables • Required number of supported Ruckus-branded transceivers Refer to the Brocade optics family datasheet for the list of supported transceivers and cables. • Required number of compatible Ethernet (RJ-45) and fiber-optic cables • Optical transceiver extraction tool (for 10-Gbps transceiver only) NOTE Most Ruckus switches come with a transceiver extraction tool and holster. The extraction tool is designed to remove transceivers from modules where the space is limited. FIGURE 55 Optical transceiver extraction tool Precautions specific to transceivers and cables DANGER The procedures in this manual are for qualified service personnel. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 83 Installing Transceivers and Cables Managing cables DANGER For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor. DANGER All fiber-optic interfaces use Class 1 lasers. DANGER Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do not comply with these standards might emit light that is hazardous to the eyes. CAUTION Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface. Managing cables Cables can be organized and managed in a variety of ways, for example, using cable channels on the sides of the rack or patch panels to minimize cable management. Follow these recommendations: NOTE You should not use tie wraps with optical cables because they are easily overtightened and can damage the optic fibers. CAUTION Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface. • The minimum bend radius for a 50 micron cable is 2 inches under full tensile load and 1.2 inches with no tensile load. • Plan for rack space required for cable management before installing the switch. • Leave at least 1 m (3.28 ft) of slack for each port cable. This provides room to remove and replace the switch, allows for inadvertent movement of the rack, and helps prevent the cables from being bent to less than the minimum bend radius. • If you are using Brocade ISL Trunking, consider grouping cables by trunking groups. The cables used in trunking groups must meet specific requirements, as described in the Brocade optics family datasheet. • For easier maintenance, label the fiber-optic cables and record the devices to which they are connected. • Keep LEDs visible by routing port cables and other cables away from the LEDs. • Use hook and loop style straps to secure and organize fiber-optic cables. Installing the Ethernet RJ-45 cables The device supports connection to other vendors’ routers, switches, hubs, as well as other Ruckus devices through the appropriate ports, transceivers, and cables. • 84 For copper connections to Ethernet hubs, a 10/100Base-TX or 1000Base-T switch, or another Brocade device, a crossover cable is required as shown in the following figure. If the hub is equipped with an uplink port, it requires a straight-through cable instead of a crossover cable. The 802.3ab standard (automatic MDI or MDIX detection) calls for automatic negotiation of the connection between two 1000Base-T ports. In this case, a straight-through cable may work just as well as a crossover cable. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Installing Transceivers and Cables Installing the Ethernet RJ-45 cables FIGURE 56 UTP crossover cable • Straight-through UTP cabling is required for direct UTP attachment to workstations, servers, or routers using network interface cards (NICs). Fiber-optic cabling is required for direct attachment to Gigabit NICs or switches and routers through fiber ports. FIGURE 57 Straight-through cable • All 10/100 and 1000 Mbps Ethernet copper ports on the devices support automatic Media Dependent Interface (auto-MDI) or automatic Media Dependent Interface Crossover (auto-MDIX) detection. Auto-MDI or auto-MDIX is enabled on all 10/100 and 1000 Mbps copper ports by default. For each port, you can disable auto-MDI or auto-MDIX, designate the port as an MDI port, or designate the port as an MDIX port. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 85 Installing Transceivers and Cables Cleaning the fiber-optic connectors Cleaning the fiber-optic connectors To avoid problems with the connection between the fiber-optic transceiver (SFP+ or QSFP) and the fiber cable connectors, Brocade strongly recommends cleaning both connectors each time you disconnect and reconnect them. Dust can accumulate on the connectors and cause problems such as reducing the optic launch power. To clean the fiber cable connectors, Brocade recommends using a fiber-optic reel-type cleaner. When not using an SFP+, or QSFP connector, make sure to keep the protective covering in place. Installing a new fiber-optic transceiver For direct attachment from the device to a Gigabit NIC, switch, or router, using a fiber-optic transceiver, you need fiber cabling with an LC connector. You can install a new fiber-optic transceiver in an SFP or SFP+ slot while the device is powered on and running. While installing a transceiver, wear an ESD wrist strap with a plug that can be inserted in the ESD connector on the device. DANGER For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor. DANGER All fiber-optic interfaces use Class 1 lasers. Perform the following steps to install a fiber-optic transceiver. 86 1. Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack) to act as ground. 2. Remove the new transceiver from the protective packaging. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Installing Transceivers and Cables Cabling a fiber-optic transceiver 3. Gently insert the transceiver into the slot until it clicks into place. Transceivers are keyed to prevent incorrect insertion. NOTE The location of the fiber-optic interface shown is for illustration purposes only. They may be in a slightly different location on the device you are using. FIGURE 58 Installing a transceiver 1. Transceiver NOTE If a 1-Gbps optic transceiver is inserted, you must configure the port using the speed-duplex 1000-full-master command at the interface level. Cabling a fiber-optic transceiver Perform the following steps to cable a fiber-optic transceiver. 1. Remove the protective covering from the fiber-optic port connectors and store the covering for future use. NOTE Before cabling a fiber-optic transceiver, Ruckus strongly recommends cleaning the cable connectors and the port connectors. 2. Gently insert the cable connector (a tab on each connector should face upward) into the transceiver connector until the tabs lock into place. 3. Observe the link and active LEDs to determine if the network connections are functioning properly. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 87 Installing Transceivers and Cables Replacing a fiber-optic transceiver Replacing a fiber-optic transceiver You can replace a fiber-optic SFP+ transceiver while the device is powered on and running. While replacing a fiber-optic module, be sure to wear an ESD wrist strap with a plug that can be inserted in the ESD connector on the device. DANGER For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor. To replace a transceiver from an SFP+ slot, complete the following steps. 1. Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack). 2. Disconnect the cable connector from the port connector. 3. Unlock the transceiver by pulling the bail latch forward, away from the front panel of the module. This unlocks the module from the front panel. NOTE On 1000Base-SX ports, the bail latch is enclosed in a black sleeve, and on 1000Base-LX ports, the bail latch is enclosed in a blue sleeve. FIGURE 59 Unlocking the bail latch 1. Bail latch NOTE The bail latch may be attached to either the top or the bottom of the SFP transceiver. 4. Grasp the bail latch and pull the transceiver out of the port. FIGURE 60 Removing the fiber-optic module 88 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Installing Transceivers and Cables Replacing a fiber-optic transceiver 5. Store the transceiver in a safe, static-free place or in an anti-static bag. 6. If you are installing a new module or replacing a module, install the new module in the port. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 89 90 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Monitoring the Device • • • • • • Interpreting port-side LEDs......................................................................................................................................91 Interpreting nonport-side LEDs................................................................................................................................98 Pinging an IP address..............................................................................................................................................98 Tracing a route........................................................................................................................................................ 98 Digital optical monitoring......................................................................................................................................... 99 Monitoring power and cooling................................................................................................................................. 99 Interpreting port-side LEDs After you install the network cables, you can observe certain LEDs to determine if the network connections are functioning properly. The tables in this section outline the state of each LED, the status of the hardware, and any recommended action. FIGURE 61 Port-side LEDs of ICX 7150-C12P 1. Port status mode selection button 10. RJ-45 port 5 RX/TX activity LED (if blinking indicates RX/TX activity) 2. Port link status mode LED 11. PoE LED 3. Port speed status mode LED 12. RJ-45 uplink port C1 status LED 4. Member ID status mode LED 13. RJ-45 uplink port C1 RX/TX activity LED 5. USB status mode LED 14. SFP+ uplink port X1 status LED (if blinking indicates RX/TX activity) 6. PoE status mode LED 15. SFP+ uplink port X2 status LED (if blinking indicates RX/TX activity) 7. System Status LED 16. Power status LED 8. Master/Slave status LED 17. Cloud management status LED (not currently enabled) 9. Software update status LED 18. Diagnostics status LED Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 91 Monitoring the Device Interpreting port-side LEDs FIGURE 62 Port-side LEDs of ICX 7150-24 and ICX 7150-24P 1. Port status mode selection button 11. RJ-45 uplink port C1 status LED 2. Port link status mode LED 12. RJ-45 uplink port C1 RX/TX activity LED 3. Port speed status mode LED 13. SFP+ uplink port X1 status LED (if blinking indicates RX/TX activity) 4. Member ID status mode LED 14. SFP+ uplink port X2 status LED (if blinking indicates RX/TX activity) 5. USB status mode LED 15. Power status LED 6. System status LED 16. Cloud management status LED (not enabled currently) 7. Master/Slave status LED 17. Diagnostics status LED 8. Software update status LED 18. OOB Link status LED (left) 9. RJ-45 port 13 RX/TX activity LED (if blinking indicates RX/TX activity) 19. OOB Speed status LED (right) 10. PoE LED NOTE ICX 7150-24P has an additional PoE status mode LED (however not enabled currently) . 92 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Monitoring the Device Interpreting port-side LEDs FIGURE 63 Port-side LEDs of ICX 7150-48, ICX 7150-48P, and ICX 7150-48PF 1. Port status mode selection button 11. PoE LED 2. Port link status mode LED 12. RJ-45 uplink port C1 status LED 3. Port speed status mode LED 13. RJ-45 uplink port C1 RX/TX activity LED 4. Member ID status mode LED 14. SFP+ uplink port X1 status LED (if blinking indicates RX/TX activity) 5. USB status mode LED 15. SFP+ uplink port X2 status LED (if blinking indicates RX/TX activity) 6. PoE status mode LED 16. Power status LED 7. System status LED 17. Cloud management status LED (not enabled currently) 8. Master/Slave status LED 18. Diagnostics status LED 9. Software update status LED 19. OOB Link status LED (left) 10. RJ-45 port 11 RX/TX activity LED (if blinking indicates RX/TX activity) 20. OOB Link status LED (right) NOTE The ICX 7150-48 does not have the PoE status mode LED. System LEDs This section describes the system LEDs. System status LED Refer to the following table to interpret the system status LED. TABLE 12 System status LED during normal operation LED color Status of hardware Recommended action Off The device is not powered on. None Flashing green The device is initializing and running initial bootup tests. None. Steady green The device is operating normally. None. Steady amber The device is booting up or has stopped at the booting stage. None. Flashing amber The device is the crash state or the watchdog timeout state. None. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 93 Monitoring the Device Interpreting port-side LEDs Status mode LEDs You must press the status mode selection button to select the status mode to display the corresponding status on the individual port status LED. Pressing the button once shifts to the next mode in the following sequence: 1. Port link status mode (STAT) (default mode) 2. Port speed status mode (SPD) 3. Member ID status mode (ID) 4. USB status mode (USB) 5. PoE status mode NOTE When in USB mode, pressing the status mode selection button for more than 5 seconds initiates the copy files such as the image/manifest file, configuration file, and Show Tech (supportsave) from the device to the USB. Port status mode (STAT) LED The port status mode (STAT) LED displays the link status and activities of each port. Each unit within the stack will also display the local port status. Refer to the following table to interpret the port status mode LED. TABLE 13 Port status mode (STAT) LED during normal operation LED color Status of hardware Recommended action Off The port does not have a valid link. None. Steady green The link is up and there is no traffic. None. Flashing green The link is up and traffic/packets are transmitted or received. None. Steady amber In Error or Out Error. None. Clear stats CLI impacts the steady amber state, if no more error port moves out of the steady amber state. Flashing amber UDLD/LACP Blocking/ERR-DIS. None. Port speed status mode (SPD) LED Port speed status (SPD) mode displays the speed setting of each downlink and uplink port (including modules). Refer to the following table to interpret the port speed status mode LED. TABLE 14 Port speed status (SPD) LED during normal operation LED color Status of hardware Recommended action Off There is no valid link. None. Steady green Highest speed. None. Flashing green Second highest speed. None. Steady amber Third highest speed. None. Flashing amber Fourth highest speed. None. Alternating amber and green Fifth highest speed. None. 94 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Monitoring the Device Interpreting port-side LEDs Member ID status mode (ID) LED The member ID status mode (ID) LEDs display the Stack ID or SPX PE ID. Stack ID: If the switch is configured in traditional stacking mode, this LED will display the stack member ID of the unit within the stack. • Member ID LED lights Green. • Port LEDs are used to display the stack ID from 1 to 12 of each member within the stack. SPX PE ID: If the switch is configured in SPX mode, this LED will display the PE ID. • Member ID LED lights Green. • Port LEDs are used to display the PE ID from 17 to 56+ of each PE member. • Two port LEDs will be used to display the ID: Steady green for the first digit and steady amber for the second digit. • For example, LED for port #2 will show steady green and port #7 will show steady amber for PE ID #27. LED for port #3 will show steady green for 2 sec follow by a steady amber for 2 sec and continue to alternate green amber for PE ID #33. LED for port #4 will show steady green and port #10 will show steady amber for PE ID #40. Refer to the following table to interpret the member ID status mode LED. TABLE 15 Member ID status mode (ID) LED during normal operation LED color Status of hardware Recommended action Steady Green Port number is the same as the stack ID. None. Or Port number is the first digit of PE ID. Steady amber Port number is the second digit of PE ID. None. Or Port number is 10 and second digit or PE ID is 0. Alternating amber and green First and second digit of PE ID are the same. None. USB status mode LED Refer to the following tables to interpret the USB status mode LED. TABLE 16 USB status mode LED when copying files from the system flash to the USB drive is enabled LED color Status of hardware Recommended action Steady green USB is present and no operation in progress. None. Flashing green Status mode selection button has been pressed for five seconds; the USB mode copy has started. None. Steady amber USB is not detected. None. Flashing amber Copy failure or application error or USB present but mount failure/access failure. None. TABLE 17 USB status mode LED when copying files from USB to the system flash is enabled LED color Status of hardware Recommended action Steady green USB is plugged in or Auto-copy is complete. None. Flashing green The flash upgrade is initiated. None. Steady amber USB is not detected. None. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 95 Monitoring the Device Interpreting port-side LEDs TABLE 17 USB status mode LED when copying files from USB to the system flash is enabled (continued) LED color Status of hardware Recommended action Flashing amber Copy failure or application error or USB present but mount failure/access failure/corrupt. None. PoE status mode LED (N/A for non-PoE) PoE status mode displays the PoE status of each downlink port. TABLE 18 PoE status mode LED during normal operation LED color Status of hardware Recommended action Off PoE is disabled. Port is not providing PoE power. None. Steady green PoE/PoE+/PoH is on. Port is providing power. None. Flashing amber PoE is off due to a fault or not enough PoE power budget set for the port. None. Master/Slave status LED Refer to the following table to interpret the master and slave status LED. TABLE 19 Master/Slave status LED during normal operation LED color Status of hardware Recommended action Off System is standalone or stack member or PE. None. Flashing green This device is initializing as a stacking unit, and roles are being assigned. None. Flashing amber The device is in non-operational mode; that is, stacking is enabled but the current unit is not able to join the stack due to a stack-related error condition such as image mismatch, configuration mismatch, or license mismatch. The device has lost its connection with the master unit. None. Steady green Stacking mode is enabled and this device is the master unit in the stack or when the unit is standalone. None. Steady amber Stacking mode is enabled and this device is a slave unit in the stack. None. Software update status LED Refer to the following table to interpret the software update status LED. TABLE 20 Software update status LED during normal operation LED color Status of hardware Recommended action Off Software update is not enabled. None. Flashing green Software installation is in progress and it can take up to 12 minutes. None. Steady green Software auto-installation is successfully completed. None. Flashing amber Device tried to boot up from last upgraded software image but could not, booting up from a different image or image upgrade failed Contact Technical Support. Diagnostics status LED Refer to the following table to interpret the diagnostics status LED. 96 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Monitoring the Device Interpreting port-side LEDs TABLE 21 Diagnostics status LED during normal operation LED color Status of hardware Recommended action Off System is functioning normally or the device did not perform diagnostics test in the most recent reload. None. Flashing green System self-diagnostic tests are in progress. None. Steady green System self-diagnostic tests have successfully completed. None. Flashing amber System self-diagnostic test has detected a fan, thermal, or interface fault. • Check the syslog messages details. • Power cycle the device to try and clear the condition. • If the condition persists, contact Technical Support. Power status LED Refer to the following table to interpret the system power status LED. TABLE 22 System power status LED during normal operation LED color Status of hardware Off No power Recommended action • Check if internal power supply is disconnected. • Check the connections between the device, the power cord, and the wall outlet. • Contact Technical Support. Steady green Internal power supply is working normally. None. Steady amber Internal power supply for the PoE ports has failed. Contact Technical Support. OOB LED Refer to the following table to interpret the OOB LED. TABLE 23 Link status (Green): Left side LED LED color Hardware status Recommended action Off Offline None. Steady green Link is up. None. Flashing green Packet transmission or reception is occurring at the port. None. LED color Hardware status Recommended action Off Offline or linked at 10/100 Mbps. None. Steady green Linked at 1000 Mbps. None. TABLE 24 Speed status (Green): Right side LED RJ-45 Ethernet port status LED in default mode Refer to the following table to interpret individual RJ-45 Ethernet port status LED in default mode. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 97 Monitoring the Device Interpreting nonport-side LEDs TABLE 25 Ethernet port status LED in default mode LED color Status of the hardware Off A link is not established with the remote port. Recommended action • Verify that the connection to the other network device has been properly made. Also, make certain that the other network device is powered on and operating correctly. • Be sure the cable is plugged into both the device and the corresponding device. • Verify that the proper cable type is used and its length does not exceed specified limits. • Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary. • Verify that the port has not been disabled through a configuration change. You can use the CLI. If you have configured an IP address on the device, you also can use the Web management interface or Brocade Network Advisor. • If the other actions do not resolve the problem, try using a different port or a different cable. Steady green The port has established a valid link at 1000 Mbps. None. Flashing green The port has established a valid link at 1000 Mbps. Flashing indicates the port is transmitting and receiving user packets. None. Steady amber The port has established a valid link at 10 or 100 Mbps. None. Flashing amber The port has established a valid link at 10 or 100 Mbps. Flashing indicates the port is transmitting and receiving user packets. None. Interpreting nonport-side LEDs There are no LEDs found on the nonport-side view of the Ruckus ICX 7150 devices. Pinging an IP address To verify that a device can reach another device through the network, enter a command similar to the following at any level of the CLI. device> ping 10.33.4.7 NOTE If you address the ping to the IP broadcast address, the device lists the first four responses. Tracing a route To determine the path through which a device can reach another device, enter a command similar to the following at any level of the CLI on the device. device> traceroute 10.33.4.7 98 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Monitoring the Device Monitoring power and cooling The CLI displays trace route information for each hop as soon as the information is received. Traceroute requests display all responses to a given TTL. In addition, if there are multiple equal-cost routes to the destination, the device displays up to two responses by default. Digital optical monitoring You can configure your device to monitor optical transceivers in the system, either globally or by specified port. When digital optical monitoring is enabled, the system monitors the temperature and signal power levels for the optical transceivers in the specified ports. Console messages and syslog messages are sent when optical operating conditions fall below or rise above the SFP and SFP+ manufacturer’s recommended thresholds. For more information about digital optical monitoring, refer to the Ruckus FastIron Monitoring Configuration Guide. Monitoring power and cooling If the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and use the show chassis command to verify that the temperature is below the shutdown threshold. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact Brocade Technical Support for assistance. The device contains temperature sensors that the software reads based on a configurable device poll time. The device has two automatic speed fan control settings based on the temperature. To protect the device from overheating, the following temperature threshold levels exist: • The warning level is the temperature at which the device generates a syslog message. It is configurable up to 100°C (212°F). • The shutdown level is the temperature at which the device reboots. It is set by the device and is not configurable. When the device temperature reaches the shutdown level, it generates a warning message that the device’s temperature is over the shutdown level and the device shuts down in two minutes. The system restarts 120 seconds after the device reaches the temperature shutdown level. The switch fans have two speeds, low and high. The fan speed settings are set by the device, and are not configurable. During system bootup, the fans run at high speed. After bootup, the fans operate at low speed when the temperature of the switch is below the high limit temperature that is specified in the following table. If the switch reaches the high limit temperature, the fans operate at high speed until the switch reaches the low limit temperature specified in the table, at which time the fans decrease to low speed. If the switch reaches or exceeds the critical (shutdown) temperature for two minutes, the switch shuts down. NOTE In addition to the overall temperature of the device, the PoE-supported models monitor the temperature of the Power over Ethernet (PoE) power supply unit (PSU). When the low limit and high limit temperatures are reached, the PoE PSU fans change speed using the same algorithm as the module fans. There is no change to the Critical (shutdown) temperature value for these modules. TABLE 26 Temperature thresholds Model Low limit temperature High limit temperature Critical (shutdown) temperature ICX 7150-C12P Not applicable Not applicable 109°C (228°F) ICX 7150-24 Not applicable Not applicable 105°C (221°F) ICX 7150-24P 62°C (144°F) 72°C (162°F) 105°C (221°F) PoE PSU: 49°C (120°F) PoE PSU: 57°C (135°F) ICX 7150-48 Not applicable Not applicable 105°C (221°F) ICX 7150-48P 60°C(140°F) 70°C(158°F) 105°C (221°F) Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 99 Monitoring the Device Monitoring power and cooling TABLE 26 Temperature thresholds (continued) Model ICX 7150-48PF ICX 7150-48ZP Low limit temperature High limit temperature PoE PSU: 49°C (120°F) PoE PSU: 57°C (135°F) 85°C (185°F) 95°C (203°F) PoE PSU: 34°C (93°F) PoE PSU: 41°C (106°F) 85°C (185°F) 95°C (203°F) PoE PSU: 34°C (93°F) PoE PSU: 41°C (106°F) Critical (shutdown) temperature 105°C (221°F) 105°C (221°F) To display the temperature of a device, enter the show chassis command at any level of the CLI. The show chassis command displays the current temperature, the power supply status, and temperature threshold levels. The displayed temperature reflects the temperature of the board inside the device. device# show chassis The stack unit 1 chassis info: Power supply 1 (AC - PoE) present, status ok Model Number: YM-1921AB06R Serial Number: SA000V171708000081 Firmware Ver: P2H802A00 Power supply 1 Fan Air Flow Direction: Front to Back Power supply 2 (AC - PoE) present, status ok Model Number: YM-1921AB06R Serial Number: SA000V171708000083 Firmware Ver: P2H802A00 Power supply 2 Fan Air Flow Direction: Front to Back Fan 1 ok, speed (manual): 1<->[[2]] Fan 2 ok, speed (manual): 1<->[[2]] Fan controlled temperature: Rule 1/2 (MGMT THERMAL PLANE): 60.7 deg-C Rule 2/2 (PoE THERMAL PLANE): 10.0 deg-C Fan speed switching temperature thresholds: Rule 1/2 (MGMT THERMAL PLANE): Speed 1: NM<----->95 deg-C Speed 2: 85<----->105 deg-C (shutdown) Rule 2/2 (PoE THERMAL PLANE): Speed 1: NM<----->41 deg-C Speed 2: 34<----->105 deg-C (shutdown) Fan 1 Air Flow Direction: Front to Back Fan 2 Air Flow Direction: Front to Back Slot 1 Current Temperature: 61.7 deg-C (Sensor 1), 54.4 deg-C (Sensor 2), 10.0 deg-C (Sensor 3) Slot 2 Current Temperature: NA Warning level.......: 102.0 deg-C Shutdown level......: 105.0 deg-C Boot Prom MAC : 609c.9fe2.154c Management MAC: 609c.9fe2.08d6 100 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Ruckus ICX 7150 Switch Technical Specifications This content highlights the features and specifications for the Ruckus ICX 7150 switch. System specifications System component Description Enclosure 1U; 19-inch rack-mountable; desktop-, wall-, under-desk-, or magnet-mountable Power inlet C14 for AC power Power supplies Integrated AC power supply for system and PoE power Dual modular power supplies for ICX7150-48ZP Fans Fanless devices • ICX 7150-C12P • ICX 7150-24 • ICX 7150-48 Two integrated fans per device. 150 W maximum PoE budget in fanless mode. • ICX 7150-24P • ICX 7150-48P Two modular fan trays and two modular power supplies, each of which has a fan • ICX 7150-48ZP Three integrated fans per device. Fanless mode is not supported. • Cooling ICX 7150-48PF Closed airflow • ICX 7150-C12P • ICX 7150-24 • ICX 7150-48 Side-to-back airflow System architecture Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 • ICX 7150-24P • ICX 7150-48P • ICX 7150-48PF • ICX 7150-48ZP Edge Ethernet switches with full duplex switching and forwarding capabilities • 10/100/1000 Mbps RJ-45 downlink and uplink ports • 100/1000M/2.5 Gbps RJ-45 downlink ports (ICX7150-48ZP only) • PoE+ chipsets with two pair power up to Class 4 power levels of 30 W • UPoE/PoH chipsets with four pair power up to 90 W (ICX7150-48ZP only) • Optical SFP+ uplink and stacking ports 101 Ruckus ICX 7150 Switch Technical Specifications Ethernet Ethernet System component Description Ethernet ports ICX 7150-48ZP: Sixteen 2.5G and thirty-two 1G Copper ports with eight SFP+ 1G/10-GbE optical stacking or uplink ports ICX 7150-C12P: Twelve RJ-45 GbE with 802.3at PoE+, two RJ-45 GbE uplink, two SFP+ 10-GbE uplink/stacking ICX 7150-24: Twenty-four RJ-45 GbE, two RJ-45 GbE uplink, four SFP+ 10-GbE uplink/stacking ICX 7150-24P: Twenty-four RJ-45 GbE with 802.3at PoE+, two RJ-45 GbE uplink, four SFP+ 10-GbE uplink/ stacking ICX 7150-48: Forty-eight RJ-45 GbE, two RJ-45 GbE uplink, four SFP+ 10-GbE uplink/stacking ICX 7150-48P: Forty-eight RJ-45 GbE with 802.3at PoE+, two RJ-45 GbE uplink, four SFP+ 10-GbE uplink/ stacking ICX 7150-48PF: Forty-eight RJ-45 GbE with 802.3at PoE+, two RJ-45 GbE uplink, four SFP+ 10-GbE uplink/ stacking Management interface One 10/100/1000 Mbps Ethernet, out-of-band management interface (RJ-45 port) per device One Type-C USB console port per device One RJ-45 console port per device LEDs System component Description System status LEDs SYST: Bicolor LED (green/yellow) controlled by software to indicate the system status M/S: Bicolor LED (green/yellow) controlled by software to indicate master/slave status in stacking mode UPDATE: Bicolor LED (green/yellow) controlled by software to indicate the DHCP auto-configuration from DHCP server DIAG: Bicolor LED (green/yellow) controlled by software to indicate the system is in diagnostic mode CLD: Bicolor LED (green/yellow) controlled by software to indicate the connection to the cloud services platform PWR: Bicolor LED (green/yellow) indicates the internal power status Port status mode selection LEDs STAT: Bicolor LED (green/yellow) controlled by software to indicate link status (not enabled currently) SPD: Bicolor LED (green/yellow) controlled by software to indicate link speed (Stacking) ID: Port LED (green) to display stacking ID from 1 to 12 USB: Bicolor LED (green/yellow) to indicate USB flash / Show Tech / file copy / boot status POE: Bicolor LED (green/yellow) controlled by software to indicate PoE/PoE+ Port status LEDs RJ-45 link status LED: Indicates Ethernet link status and speed SFP/SFP+ status LED: Indicates link status and speed for SFP or SFP+ ports Out-of-band management port: Two single-color LEDS indicate out-of-band management port link status and speed 102 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Ruckus ICX 7150 Switch Technical Specifications Environmental requirements Other System component Description STATUS MODE Port status mode selection button RESET Reset button for hardware reset without power cycling. There is a hole in the front panel to allow access. USB port Standard type-A USB connector for removable media Console connectors RJ-45 console connector USB console Type-C connector RJ-45 connectors RJ-45 connectors for GbE data ports Weight and physical dimensions The Total weight column includes the weight of the unit and the contents of the shipping carton. Model Height Width Depth Unit weight Total weight ICX 7150-48ZP 4.37 cm 44.0 cm 33.2 cm 6.246 kg 8.282 kg With one power supply and one fan 1.72 in 17.32 in 13.1 in 13.770 lb 18.259 lb ICX 7150-48ZP 4.37 cm 44.0 cm 33.2 cm 7.415 kg 9.451 kg With two power supplies and two fans 1.72 in 17.32 in 13.1 in 16.347 lb 20.836 lb ICX 7150-C12P 4.37 cm 26.9 cm 21.3 cm 2.58 kg 3.12 kg 1.72 in 10.59 in 8.39 in 5.69 lb 6.88 lb 4.37 cm 44.0 cm 28.0 cm 3.80 kg 5.20 kg 1.72 in 17.32 in 11.0 in 8.38 lb 11.46 lb 4.37 cm 44.0 cm 28.0 cm 4.93 kg 6.35 kg 1.72 in 17.32 in 11.0 in 10.97 lb 14.00 lb 4.37 cm 44.0 cm 37.0 cm 4.82 kg 6.65 kg 1.72 in 17.32 in 14.6 in 10.63 lb 14.66 lb 4.37 cm 44.0 cm 37.0 cm 6.17 kg 7.90 kg 1.72 in 17.32 in 14.6 in 13.60 lb 17.42 lb 4.37 cm 44.0 cm 37.0 cm 6.28 kg 8.07 kg 1.72 in 17.32 in 14.6 in 13.85 lb 17.79 lb ICX 7150-24 ICX 7150-24P ICX 7150-48 ICX 7150-48P ICX 7150-48PF Environmental requirements Condition Operational Non-operational level.1 Ambient temperature -5°C (cold start). 0°C to 45°C (23°F to 113°F) at sea Relative humidity (noncondensing) 5% to 95% at 45°C (113°F) 0% to 95% at 70°C (158°F) Altitude (above sea level) 0 to 3,000 m (10,000 feet) 0 to 12,000 m (39,000 feet) Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 -25°C to 70°C (-13°F to 158°F) 103 Ruckus ICX 7150 Switch Technical Specifications Power supply specifications (per PSU) Condition Operational Non-operational Shock 20 G, 11 ms, half-sine wave 33 G, 11 ms, half-sine wave Vibration 1 G sine, 0.4 gms random, 5-500 Hz 2.4 G sine, 1.1 gms random, 5-500 Hz Airflow ICX 7150-48ZP: 40.36 CFM (Maximum), 14.6 CFM (Typical) N/A ICX 7150-C12P: 0 CFM ICX 7150-24: 0 CFM ICX 7150-24P: 37.6 CFM (Maximum), 13.4 CFM (Typical) ICX 7150-48: 0 CFM ICX 7150-48P: 38.15 CFM (Maximum), 13.9 CFM (Typical) ICX 7150-48PF: 50.8 CFM (Maximum), 19.6 CFM (Typical) Heat dissipation Refer to Power Consumption specification sections N/A Operating noise For all fanless ICX 7150 devices and devices in fanless mode: Less than 12 dBA N/A ICX 7150-24P, ICX 7150-48P, and ICX 7150-48ZP with fans running: Maximum of 52 dBA ICX 7150-48PF with fans running: Maximum of 48 dBA (fanless mode is not supported) Power supply specifications (per PSU) All the Ruckus ICX 7150 power supply units (PSUs) are fixed and internal to the device. All the PSUs use a C14 inlet and connect to standard AC power. Device Maximum output power rating (DC) Input voltage Input line frequency Maximum input current Input line protection Maximum inrush current ICX 7150-48ZP 1740 W 100 - 240 VAC 50/60 Hz 13 A (rms) Line fused 30 A at 115 VAC (nominal) (nominal) 60 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) 100 - 240 VAC 50/60 Hz (nominal) (nominal) 60 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) 100 - 240 VAC 50/60 Hz (nominal) (nominal) 80 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) ICX 7150-C12P ICX 7150-24 1 104 150 W 36 W 2.78 A (rms) 3 A (rms) Line fused Line fused 40 A at 115 VAC 40 A at 115 VAC For the ICX 7150-C12P, the maximum operating temperature is 40°C when under fully loaded PoE conditions or when installed using the long bracket (ICX7000-C12-RMK) under a fixed surface. The maximum operating temperature is 35°C when installed using the short bracket (ICX7000-C12-WMK) under a fixed surface. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Ruckus ICX 7150 Switch Technical Specifications Power consumption (idle configuration) Device Maximum output power rating (DC) Input voltage Input line frequency Maximum input current Input line protection Maximum inrush current ICX 7150-24P 525 W 100 - 240 VAC 50/60 Hz 7.23 A (rms) Line fused 30 A at 115 VAC (nominal) (nominal) 60 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) 100 - 240 VAC 50/60 Hz (nominal) (nominal) 80 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) 100 - 240 VAC 50/60 Hz (nominal) (nominal) 60 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) 100 - 240 VAC 50/60 Hz (nominal) (nominal) 120 A at 230 VAC 90 - 264 VAC 47 - 63 Hz Cold start @ 25°C (range) (range) ICX 7150-48 ICX 7150-48P ICX 7150-48PF 65 W 525 W 880 W 5.4 A (rms) Line fused 11.25 A (rms) Line fused 14.45 A (rms) Line fused 40 A at 115 VAC 30 A at 115 VAC 60 A at 115 VAC Power consumption (idle configuration) Idle: No optics or connections to ports installed and system booted up. Fans at nominal speed. Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-48ZP 0.82 A 0.5 A N/A 1 With one power supply and one fan 89 W 85.89 W All ports down, no optics or cables connected. 303.68 BTU/hr 293.07 BTU/hr No Load (traffic) ICX 7150-48ZP 1.14 A 0.7 A With two power supplies and two fans 108 W 105.4 W 368.51 BTU/hr 359.64 BTU/hr ICX 7150-C12P 0.22 A 0.16 A 20.10 W 19.5 W All ports down, no optics or cables connected. 68.60 BTU/hr 68.09 BTU/hr No Load (traffic) 0.25 A 0.16 A 13.88 W 13.53 W 47.37 BTU/hr 46.18 BTU/hr 0.35 A 0.29 A 31.58 W 30.64 W All ports down, no optics or cables connected. 107.79 BTU/hr 104.58 BTU/hr No Load (traffic) ICX 7150-24 ICX 7150-24P Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 N/A 2 N/A 1 All ports down, no optics or cables connected. No Load (traffic) N/A 1 N/A 1 All ports down, no optics or cables connected. No Load (traffic) 105 Ruckus ICX 7150 Switch Technical Specifications Power consumption (typical configuration) Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-48 0.46 A 0.28 A N/A 1 24.19 W 23.55 W All ports down, no optics or cables connected. 82.56 BTU/hr 80.38 BTU/hr 0.50 A 0.35 A N/A 1 46.90 W 46.80 W All ports down, no optics or cables connected. 160.07 BTU/hr 159.73 BTU/hr No Load (traffic) 0.53 A 0.37 A 49.90 W 49.33 W All ports down, no optics or cables connected. 170.31 BTU/hr 168.37 BTU/hr No Load (traffic) ICX 7150-48P ICX 7150-48PF No Load (traffic) N/A 1 Fans always running. Power consumption (typical configuration) Typical: 10% traffic rate on all ports with 64-byte packet size and random payload at room temperature. All ports fully configured. Fans at nominal speed. Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-48ZP 9.29 A 4.41 A N/A 1 With one power supply and one fan 917 W 870 W All 2.5G and 1G ports and eight 10G ports are linked UP 3218.935 BTU/hr 2968.56 BTU/hr 10% traffic 100% PoE Load @ Class 3 (15.4W per port, Total 740W) ICX 7150-48ZP 18.29 A 8.63 A N/A 2 With two power supplies and two fans 1804 W 1868 W All 2.5G and 1G ports and eight 10G ports are linked UP 6155.5 BTU/hr 5752,87 BTU/hr 10% traffic 100% PoE Load @ Class 3 (15.4W per port, Total 740W) ICX 7150-C12P 1.59 A 0.80 A N/A 1 157.12 W 153.31 W 12 1-GbE and 2 10GbE ports are linked UP ONLY. 536.26 BTU/hr 523.26 BTU/hr 10% traffic. 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-24 106 0.42 A 0.26 A N/A 1 23.87 W 23.37 W 24 1-GbE and 4 10GbE ports are linked UP ONLY. 81.47 BTU/hr 76.76 BTU/hr 10% traffic. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Ruckus ICX 7150 Switch Technical Specifications Power consumption (maximum configuration) Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-24P 4.57 A 2.24 A N/A 1 455.39 W 438.75 W 24 1-GbE and 4 10GbE ports are linked UP ONLY. 1554.28 BTU/hr 1497.49 BTU/hr 10% traffic. 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-48 ICX 7150-48P 0.74 A 0.45 A N/A 38.49 W 39.02 W 48 1-GbE and 4 10GbE ports are linked UP ONLY. 131.37 BTU/hr 133.18 BTU/hr 10% traffic. 4.88 A 2.35 A 476.30 W 460.60 W 48 1-GbE and 4 10GbE ports are linked UP ONLY. 1625.65 BTU/hr 1572.06 BTU/hr 10% traffic. N/A 1 1 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-48PF 9.56 A 4.45 A N/A 1 922.0 W 868.54 W 48 1-GbE and 4 10GbE ports are linked UP ONLY. 3146.86 BTU/hr 2964.40 BTU/hr 10% traffic. 100% PoE Load @ Class 3 (15.4 W/port) Power consumption (maximum configuration) Maximum: All ports fully configured with connection and traffic at maximum throughput. Fans at high speed. Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-48ZP 9.46 A 4.54 A N/A 1 With one power supply and one fan 932 W 888 W All 2.5G and 1G ports and eight 10G ports are linked UP 3180.12 BTU/hr 3029.98 BTU/hr 100% traffic 100% PoE Load @ Class 3 (15.4W per port, Total 740W) Fan at high speed ICX 7150-48ZP 18.66 A 8.8 A N/A 2 With two power supplies and two fans 1841 W 1720 W All 2.5G and 1G ports and eight 10G ports are linked UP 6281.75 BTU/hr 5868.88 BTU/hr 100% traffic 100% PoE Load @ Class 3 (15.4W per port, Total 740W) Fans at high speed Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 107 Ruckus ICX 7150 Switch Technical Specifications Data port specifications (Ethernet) Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of power supplies Notes ICX 7150-C12P 1.59 A 0.80 A N/A 1 157.21 W 153.39 W 12 1-GbE and 2 10GbE ports are linked UP ONLY. 536.57 BTU/hr 523.53 BTU/hr 100% traffic. 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-24 ICX 7150-24P 0.42 A 0.27 A N/A 1 23.96 W 24.19 W 24 1-GbE and 4 10GbE ports are linked UP ONLY. 81.78 BTU/hr 82.56 BTU/hr 100% traffic. 4.74 A 2.32 A 471.85 W 454.62 W 24 1-GbE and 4 10GbE ports are linked UP ONLY. 1610.46 BTU/hr 1551.65 BTU/hr 100% traffic. N/A 1 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-48 ICX 7150-48P 0.74 A 0.46 A N/A 1 N/A 1 48 1-GbE and 4 10GbE ports are linked UP ONLY. 38.78 W 39.14 W 132.36 BTU/hr 133.59 BTU/hr 5.03 A 2.42 A 491.32 W 475.0 W 48 1-GbE and 4 10GbE ports are linked UP ONLY. 1676.91 BTU/hr 1621.21 BTU/hr 10% traffic. 100% traffic. 100% PoE Load @ Class 3 (15.4 W/port) ICX 7150-48PF 9.82 A 4.57 A N/A 1 949.33 W 893.30 W 48 1-GbE and 4 10GbE ports are linked UP ONLY. 3240.14 BTU/hr 3048.90 BTU/hr 10% traffic. 100% PoE Load @ Class 3 (15.4 W/port) Data port specifications (Ethernet) NOTE The ICX 7150 10-GbE ports provide both active and passive cable support. Model Port type Number of ports Description ICX 7150-48ZP 1 GbE (copper) 48 downlink RJ-45 10/100/1000 Mbps ports 2.5 GbE (copper) 16 downlink RJ-45 100/1000 M/2.5 Gbps ports 1/10 GbE (optical) 4 uplink and 4 stacking SFP+ ports GbE (copper) 12 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports 10 GbE (optical) 2 uplink or stacking SFP+ ports GbE (copper) 24 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports ICX 7150-C12P ICX 7150-24 108 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Ruckus ICX 7150 Switch Technical Specifications Memory specifications Model ICX 7150-24P ICX 7150-48 ICX 7150-48P ICX 7150-48PF Port type Number of ports Description 10 GbE (optical) 4 uplink or stacking SFP+ ports GbE (copper) 24 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports 10 GbE (optical) 4 uplink or stacking SFP+ ports GbE (copper) 48 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports 10 GbE (optical) 4 uplink or stacking SFP+ ports GbE (copper) 48 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports 10 GbE (optical) 4 uplink or stacking SFP+ ports GbE (copper) 48 downlink + 2 uplink RJ-45 10/100/1000 Mbps ports 10 GbE (optical) 4 uplink or stacking SFP+ ports Serial port specifications (pinout RJ-45) Pin Signal Description 1 Not supported N/A 2 Not supported N/A 3 UART1_TXD Transmit data 4 GND Logic ground 5 GND Logic ground 6 UART1_RXD Receive data 7 Not supported N/A 8 Not supported N/A Serial port specifications (protocol) Parameter Value Baud 9600 bps Data bits 8 Parity None Stop bits 1 Flow control None Memory specifications Memory Type Size Boot Flash SPI NOR Flash 2 x 8 MB Compact Flash NAND Fash (MLC) 2 GB Main Memory DDR4 SDRAM (not ECC capable) 1 GB Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 109 Ruckus ICX 7150 Switch Technical Specifications Regulatory compliance (EMC) Regulatory compliance (EMC) • FCC Part 15, Subpart B • EN 55024 • EM 55032 (CE Mark) (Class A) • ICES-003 • VCCI • EN 300 386 • CNS 13438 • KN 32 • KN 35 • TCVN 7189 • EN 61000-3-2 • EN 61000-3-3 • GB 9254 • CISPR 32 • 2014/30/EU • AS/NZS CISPR32 (Australia) (Class A) Regulatory compliance (safety) • EN/UL 60825 • EN/UL/CSA/IEC 60950-1 • GB 4943.1 • CNS 14336-1 • 2014/35/EU Regulatory compliance (environmental) 110 • 2011/65/EU - Restriction of the use of certain hazardous substance in electrical and electronic equipment (EU RoHS). • 2012/19/EU - Waste electrical and electronic equipment (EU WEEE). • 94/62/EC - packaging and packaging waste (EU). • 2006/66/EC - batteries and accumulators and waste batteries and accumulators (EU battery directive). • 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (EU REACH). • Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act of 2010 - U.S. Conflict Minerals. • 30/2011/TT-BCT - Vietnam circular. • SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China). • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China). Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Regulatory Statements • • • • • • • • • • CE statement........................................................................................................................................................ 111 China ROHS..........................................................................................................................................................111 BSMI statement (Taiwan)....................................................................................................................................... 111 Canadian requirements..........................................................................................................................................112 China CCC statement........................................................................................................................................... 112 Europe and Australia (CISPR 32 Class A Warning).................................................................................................113 FCC warning (US only).......................................................................................................................................... 113 Germany statement...............................................................................................................................................113 KCC statement (Republic of Korea)....................................................................................................................... 113 VCCI statement..................................................................................................................................................... 113 CE statement ATTENTION This is a Class A product. In a domestic environment, this product might cause radio interference, and the user might be required to take corrective measures. The standards compliance label on this device contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives, laws, and standards: • Electromagnetic Compatibility (EMC) Directive 2014/30/EU • Low Voltage Directive (LVD) 2014/35/EU • EN 55032/EN 55024 (European Immunity Requirements) – – EN61000-3-2/JEIDA (European and Japanese Harmonics Spec) EN61000-3-3 China ROHS Refer to the latest revision of the China ROHS document (P/N 53‐1000428‐xx) which ships with the product. BSMI statement (Taiwan) Warning: This is Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 111 Regulatory Statements Canadian requirements Canadian requirements This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations, ICES-003 Class A. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. China CCC statement 112 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Regulatory Statements VCCI statement Europe and Australia (CISPR 32 Class A Warning) This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC warning (US only) This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense. Germany statement Machine noise information regulation - 3. GPSGV, the highest sound pressure level value is 70.0 dB(A) in accordance with EN ISO 7779. Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70.0 dB(A) gemäss EN ISO 7779. KCC statement (Republic of Korea) Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. VCCI statement This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 113 114 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Cautions and Danger Notices • • Cautions................................................................................................................................................................115 Danger Notices..................................................................................................................................................... 118 Cautions A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. Ein Vorsichthinweis warnt Sie vor potenziellen Personengefahren oder Beschädigung der Hardware, Firmware, Software oder auch vor einem möglichen Datenverlust Un message de mise en garde vous alerte sur des situations pouvant présenter un risque potentiel de dommages corporels ou de dommages matériels, logiciels ou de perte de données. Un mensaje de precaución le alerta de situaciones que pueden resultar peligrosas para usted o causar daños en el hardware, el firmware, el software o los datos. General cautions CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. VORSICHT Falls dieses Gerät verändert oder modifiziert wird, ohne die ausdrückliche Genehmigung der für die Einhaltung der Anforderungen verantwortlichen Partei einzuholen, kann dem Benutzer der weitere Betrieb des Gerätes untersagt werden. MISE EN GARDE Les éventuelles modifications apportées à cet équipement sans avoir été expressément approuvées par la partie responsable d'en évaluer la conformité sont susceptibles d'annuler le droit de l'utilisateur à utiliser cet équipement. PRECAUCIÓN Si se realizan cambios o modificaciones en este dispositivo sin la autorización expresa de la parte responsable del cumplimiento de las normas, la licencia del usuario para operar este equipo puede quedar anulada. CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 45°C (113°F). VORSICHT Das Gerät darf nicht in einer Umgebung mit einer Umgebungsbetriebstemperatur von über 45°C (113°F) installiert werden. MISE EN GARDE N'installez pas le dispositif dans un environnement où la température d'exploitation ambiante risque de dépasser 45°C (113°F). PRECAUCIÓN No instale el instrumento en un entorno en el que la temperatura ambiente de operación pueda exceder los 45°C (113°F). CAUTION Make sure the airflow around the front, and back of the device is not restricted. VORSICHT Stellen Sie sicher, dass an der Vorderseite, den Seiten und an der Rückseite der Luftstrom nicht behindert wird. MISE EN GARDE Vérifiez que rien ne restreint la circulation d'air devant, derrière et sur les côtés du dispositif et qu'elle peut se faire librement. PRECAUCIÓN Asegúrese de que el flujo de aire en las inmediaciones de las partes anterior, laterales y posterior del instrumento no esté restringido. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 115 Cautions and Danger Notices Cautions CAUTION Never leave tools inside the chassis. VORSICHT Lassen Sie keine Werkzeuge im Chassis zurück. MISE EN GARDE Ne laissez jamais d'outils à l'intérieur du châssis PRECAUCIÓN No deje nunca herramientas en el interior del chasis. CAUTION To protect the serial port from damage, keep the cover on the port when not in use. VORSICHT Um den seriellen Anschluss vor Beschädigungen zu schützen, sollten Sie die Abdeckung am Anschluss belassen, wenn er nicht verwendet wird. MISE EN GARDE Mettre le bouchon de protection sur le port série lorsqu'il ne sert pas pour éviter de l'endommager. PRECAUCIÓN Para evitar que se dañe el puerto serie, mantenga la cubierta colocada sobre el puerto cuando no lo utilice. CAUTION Before mounting the device using the magnet sheet, make sure the rubber feet are not installed on the device to ensure that the magnet sheet holds on to the device strongly and does not detach. If the rubber feet are already installed, remove them first before attaching the magnet sheet. VORSICHT Die Gummifüße sollten vor dem Anbringen des Geräts mittels der Magnetplatte noch nicht montiert sein. So stellen Sie sicher, dass die Magnetplatte fest am Gerät sitzt und sich nicht löst. Wenn die Gummifüße bereits montiert sind, entfernen Sie diese vor dem Anbringen der Magnetplatte. MISE EN GARDE Avant d'installer l'appareil en utilisant la feuille magnétique, assurez-vous que les pieds en caoutchouc ne sont pas installés sur l'appareil pour s'assurer que la feuille magnétique tient fermement sur l'appareil et ne se détache pas. Si les pieds en caoutchouc sont déjà installés, les enlever d'abord avant de fixer la feuille magnétique. PRECAUCIÓN Antes de montar el dispositivo mediante el uso la lámina magnetica asegúrese de que las bases de goma no estén instaladas sobre el dispositivo para garantizar que la lámina magnetica se adhiera al dispositivo con firmeza y no se desprenda. Si las bases de goma ya están instaladas, primero remuevalas antes de colocar la lámina magnetica. CAUTION The magnet sheet can only be placed against the bottom panel of the device. Do not attempt to attach the magnet sheet to any other panels on the device. VORSICHT Die magnetische Matte kann nur an der Unterseite des Geräts angebracht werden. Versuchen Sie nicht, die magnetische Matte an den anderen Seiten des Geräts anzubringen. MISE EN GARDE Il est uniquement possible de placer la feuille magnétique contre la face inférieure du dispositif. Ne tentez pas de placer la feuille magnétique à d'autres endroits. PRECAUCIÓN La hoja magnética solo se puede colocar sobre el panel inferior del dispositivo. No intente conectar la hoja magnética a ningún otro panel del dispositivo. CAUTION Do not mount the device on a surface with the top panel facing downward. Mount the device only on a vertical metal surface with the front panel port-side facing downward. VORSICHT Montieren Sie das Gerät nicht mit der Oberseite nach unten auf einer Oberfläche. Montieren Sie das Gerät nur mit der Vorderseite (portseitig) nach unten auf einer vertikalen Metalloberfläche. MISE EN GARDE N'installez pas l'appareil avec le panneau supérieur faisant face vers le bas. Pour un montage vertical, installez l'appareil sur une surface métallique avec le panneau avant (côté ports ) faisant face vers le bas. PRECAUCIÓN No instale el dispositivo sobre una superficie con el panel superior mirando hacia abajo. Instale el dispositivo solamente sobre una superficie metálica vertical con el panel frontal de los puertos de usuario orientado hacia abajo. 116 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Cautions and Danger Notices Cautions CAUTION Ensure that the metal surface is flat and the texture is smooth to hold the device strongly. Check for other conditions that might impede secure magnetic mount. VORSICHT Achten Sie darauf, dass die Metalloberfläche eben und glatt ist, damit das Gerät sicher montiert werden kann. Prüfen Sie andere Bedingungen, die eine sichere magnetische Montage beeinflussen könnten. MISE EN GARDE Assurez-vous que la surface métallique est plane et lisse afin de maintenir l'appareil fermement en place. Vérifiez qu'il n'y a pas d'autres conditions qui pourraient nuire à une installation sécuritaire. PRECAUCIÓN Asegúrese de que la superficie metálica sea plana y de que la textura sea pareja para sostener el dispositivo con firmeza. Esté atento a otras condiciones que puedan impedir una instalación segura del montaje magnetico. CAUTION When mounting the device under a fixed surface, under a desk, or under a shelf, use the long brackets to provide adequate ventilation and not exceed the operating temperature. VORSICHT Wenn Sie das Gerät unter einer festen Oberfläche, einem Tisch oder einem Regal montieren, verwenden Sie die langen Halterungen, um für eine angemessene Belüftung zu sorgen und die Betriebstemperatur nicht zu überschreiten. MISE EN GARDE Lors du montage de l’appareil sous une surface fixe (sous un bureau ou une étagère), utilisez les supports longs pour assurer d'une ventilation adéquate et pour que l'appareil ne surchauffe pas. PRECAUCIÓN Cuando instale el dispositivo debajo de una superficie fija, debajo de un escritorio o debajo de un estante, utilice las abrazaderas largas para proporcionar una ventilación adecuada y no superar la temperatura operativa. Electrical cautions CAUTION Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface. VORSICHT Bevor Sie ein Kabel in einen Anschluss einstecken, entladen Sie jegliche im Kabel vorhandene elektrische Spannung, indem Sie mit den elektrischen Kontakten eine geerdete Oberfläche berühren. MISE EN GARDE Avant de brancher un câble à un port, assurez-vous de décharger la tension du câble en reliant les contacts électriques à la terre. PRECAUCIÓN Antes de conectar un cable en cualquier puerto, asegúrese de descargar la tensión acumulada en el cable tocando la superficie de conexión a tierra con los contactos eléctricos. CAUTION Static electricity can damage the chassis and other electronic devices. To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them. VORSICHT Statische Elektrizität kann das System und andere elektronische Geräte beschädigen. Um Schäden zu vermeiden, entnehmen Sie elektrostatisch empfindliche Geräte erst aus deren antistatischer Schutzhülle, wenn Sie bereit für den Einbau sind. MISE EN GARDE L'électricité statique peut endommager le châssis et les autres appareils électroniques. Pour éviter tout dommage, conservez les appareils sensibles à l'électricité statique dans leur emballage protecteur tant qu'ils n'ont pas été installés. PRECAUCIÓN La electricidad estática puede dañar el chasis y otros dispositivos electrónicos. A fin de impedir que se produzcan daños, conserve los dispositivos susceptibles de dañarse con la electricidad estática dentro de los paquetes protectores hasta que esté listo para instalarlos. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 117 Cautions and Danger Notices Danger Notices CAUTION Do not use the port cover tabs to lift the module. They are not designed to support the weight of the module, which can fall and be damaged. VORSICHT Verwenden Sie nicht die Laschen der Anschlussabdeckungen um ein Modul anzuheben. Diese sind nicht auf das Gewicht des Moduls ausgelegt, welches herunterfallen und dabei beschädigt werden kann. MISE EN GARDE N'utilisez pas les languettes du boîtier du port pour soulever le module. Elles ne sont pas conçues pour supporter le poids du module, qui peut tomber et être endommagé. PRECAUCIÓN No utilice las pestañas de la tapa del puerto para levantar el módulo. No están diseñadas para soportar el peso del módulo, por lo que este podría caerse y resultar dañado. CAUTION Use the screws specified in the procedure. Using longer screws can damage the device. VORSICHT Verwenden Sie die in der Anleitung aufgeführten Schrauben. Mit längeren Schrauben wird das Gerät möglicherweise beschädigt. MISE EN GARDE Utilisez les vis mentionnées dans les instructions. L'utilisation de vis plus longues peut endommager l'appareil. PRECAUCIÓN Utilice los tornillos especificados en el procedimiento. Si utiliza tornillos de mayor longitud, podría dañar el dispositivo. CAUTION Ensure that adequate ventilation is provided for the system. A 3 cm clearance is recommended above the device and 8 cm clearance is recommended on each side. VORSICHT Stellen Sie sicher, dass das System ausreichend belüftet wird. Über dem Gerät wird 3 cm Freiraum, auf beiden Seiten jeweils 8 cm Freiraum empfohlen. MISE EN GARDE Assurez-vous que le circuit est correctement ventilé. Il est recommandé de conserver un espace de 3 cm au-dessus du dispositif, et de 8 cm sur chaque côté. PRECAUCIÓN Asegúrese de proporcionar una ventilación adecuada al sistema. Se recomienda dejar 3 cm de espacio libre por encima del dispositivo y 8 cm a cada lado. CAUTION Ensure that adequate ventilation and airflow is provided for the system. A 4.5 cm (1.77 in) clearance is recommended above and below the device and 8 cm (3.15 in) clearance is recommended on each side. VORSICHT Achten Sie auf eine angemessene Belüftung und Luftzufuhr für das System. Ein Abstand von 4,5 cm über und unter dem Gerät und von 8 cm auf jeder Seite wird empfohlen. MISE EN GARDE Assurez-vous que le système est correctement ventilé . Un dégagement de 4,5 cm (1,77 po) est recommandé au-dessus et en dessous de l'appareil et un dégagement de 8 cm (3,15 po) est recommandé de chaque côté. PRECAUCIÓN Asegure una ventilación y un flujo de aire adecuados para el sistema. Se recomienda una holgura de 4.5 cm (1.77 in) por encima y por debajo del dispositivo, y 8 cm (3.15 in) en cada lado. Danger Notices A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations. Ein Gefahrenhinweis warnt vor Bedingungen oder Situationen die tödlich sein können oder Sie extrem gefährden können. Sicherheitsetiketten sind direkt auf den jeweiligen Produkten angebracht um vor diesen Bedingungen und Situationen zu warnen. Un énoncé de danger indique des conditions ou des situations potentiellement mortelles ou extrêmement dangereuses. Des étiquettes de sécurité sont posées directement sur le produit et vous avertissent de ces conditions ou situations. 118 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Cautions and Danger Notices Danger Notices Una advertencia de peligro indica condiciones o situaciones que pueden resultar potencialmente letales o extremadamente peligrosas. También habrá etiquetas de seguridad pegadas directamente sobre los productos para advertir de estas condiciones o situaciones. General dangers DANGER The procedures in this manual are for qualified service personnel. GEFAHR Die Vorgehensweisen in diesem Handbuch sind für qualifiziertes Servicepersonal bestimmt. DANGER Les procédures décrites dans ce manuel doivent être effectuées par un personnel de maintenance qualifié. PELIGRO Los procedimientos de este manual deben llevarlos a cabo técnicos cualificados. DANGER Be careful not to accidently insert your fingers into the fan tray while removing it from the chassis. The fan may still be spinning at a high speed. GEFAHR Die Finger dürfen nicht versehentlich in das Ventilatorblech gesteckt werden, wenn dieses vom Gehäuse abgenommen wird. Der Ventilator kann sich unter Umständen noch mit hoher Geschwindigkeit drehen. DANGER Faites attention de ne pas insérer vos doigts accidentellement dans le boîtier du ventilateur lorsque vous le retirez du châssis. Il est possible que le ventilateur tourne encore à grande vitesse. PELIGRO Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. DANGER This equipment is suitable for mounting on concrete or other noncombustible surfaces only. GEFAHR Dieses Gerät darf nur auf Beton oder auf andere, nicht brennbare Flächen installiert werden. DANGER Cet équipement est adapté à être monté sur du béton ou seulement sur d'autres surfaces non combustibles. PELIGRO Este equipo es apto para el montaje solamente en superficies de concreto ó en otro tipos de superficies no combustibles. Electrical dangers DANGER For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor. GEFAHR Aus Sicherheitsgründen sollte ein EGB-Armband zum Schutz von elektronischen gefährdeten Bauelementen mit einem 1 Megaohm-Reihenwiderstand ausgestattet sein. DANGER Pour des raisons de sécurité, la dragonne ESD doit contenir une résistance de série 1 méga ohm. PELIGRO Por razones de seguridad, la correa de muñeca ESD deberá contener un resistor en serie de 1 mega ohmio. DANGER Make sure that the power source circuits are properly grounded. GEFAHR Achten Sie darauf, dass die Stromquellen-Schaltkreise ordnungsgemäß geerdet sind. DANGER Assurez-vous que les circuits de la source d'alimentation soient équipés de mise à la terre. PELIGRO Asegúrese que los circuitos de la fuente de energia cuenten con una conexión a tierra apropriada. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 119 Cautions and Danger Notices Danger Notices DANGER This device might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing. GEFAHR Dieses System ist möglicherweise mit mehr als einem Netzkabel ausgestattet. Trennen Sie stets die Verbindung aller Netzkabel, bevor Sie Wartungsarbeiten durchführen, um dieGefahr eines Stromschlags auszuschließen. DANGER Ce commutateur peut comporter plusieurs cordons d'alimentation. Pour réduire les risques de choc électrique, déconnectez tous les cordons d’alimentation avant d’effectuerl’entretien de l’appareil. PELIGRO Este conmutador podría tener más de un cable de alimentación. Para reducir el riesgo de sufrir una descarga eléctrica, desconecte todos los cables de alimentación antes de proceder con la reparación. DANGER Make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device. GEFAHR Achten Sie darauf, dass Sie ein Netzstromkabel verwenden, das entsprechend Ihrer nationalen Sicherheitsvorschriften gekennzeichnet ist. Durch die Kennzeichnung ist sichergestellt, dass das Netzkabel gefahrlos für das Gerät verwendet werden kann. DANGER Assurez-vous d'utiliser un cordon d'alimentation portant la marque de l'organisme responsable des normes de sécurité locales. Cette marque vous assure que vous pouvez utiliser le cordon d'alimentation avec le dispositif en toute sécurité. PELIGRO Asegúrese de utilizar un cable de alimentación que muestre la marca de la agencia de seguridad que define las normas para los cables de alimentación en su país. La marca es su garantía de que el cable de alimentación puede utilizarse de forma segura con el dispositivo. DANGER To reduce the risk of electric shock, disconnect all power cords before servicing. GEFAHR Trennen Sie stets die Verbindung aller Netzkabel, bevor Sie Wartungsarbeiten durchführen, um die Gefahr eines Stromschlags auszuschließen. DANGER Afin de réduire les risques de choc électrique, débranchez tous les cordons d’alimentation avant d’effectuer l’entretien de l’appareil. PELIGRO Para reducir el riesgo de descarga eléctrica, desconecte todos los cables de alimentación antes de darle servicio. DANGER Disconnect the power cord from all power sources to completely remove power from the device. GEFAHR Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem Gerät kein Strom zugeführt wird. DANGER Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper complètement l'alimentation du dispositif. PELIGRO Para desconectar completamente la corriente del instrumento, desconecte el cordón de corriente de todas las fuentes de corriente. DANGER To avoid high voltage shock, do not open the device while the power is on. GEFAHR Das eingeschaltete Gerät darf nicht geöffnet werden, da andernfalls das Risiko eines Stromschlags mit Hochspannung besteht. DANGER Afin d'éviter tout choc électrique, n'ouvrez pas l'appareil lorsqu'il est sous tension. PELIGRO Para evitar una descarga de alto voltaje, no abra el dispositivo mientras esté encendido. 120 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 Cautions and Danger Notices Danger Notices DANGER If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device. GEFAHR Falls für die Installation ein anderes Stromkabel erforderlich ist (wenn das mit dem Gerät gelieferte Kabel nicht passt), müssen Sie sicherstellen, dass Sie ein Stromkabel mit dem Siegel einer Sicherheitsbehörde verwenden, die für die Zertifizierung von Stromkabeln in Ihrem Land zuständig ist. Das Siegel ist Ihre Garantie, dass das Stromkabel sicher mit Ihrem Gerät verwendet werden kann. DANGER Si l'installation nécessite un cordon d'alimentation autre que celui fourni avec le dispositif, assurez-vous d'utiliser un cordon d'alimentation portant la marque de l'organisation responsable de la sécurité qui définit les normes et régulations pour les cordons d'alimentation dans votre pays. Cette marque vous assure que vous pouvez utiliser le cordon d'alimentation avec le dispositif en toute sécurité. PELIGRO Si la instalación requiere un cordón de corriente distinto al que se ha suministrado con el instrumento, verifique que usa un cordón de corriente que venga con la marca de la agencia de seguridad que defina las regulaciones para cordones de corriente en su país. Esta marca será su garantía de que el cordón de corriente puede ser utilizado con seguridad con el instrumento. Dangers related to equipment weight DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. GEFAHR Stellen Sie sicher, dass das Gestell für die Unterbringung des Geräts auf angemessene Weise gesichert ist, so dass das Gestell oder der Schrank nicht wackeln oder umfallen kann. DANGER Vérifiez que le bâti abritant le dispositif est bien fixé afin qu'il ne devienne pas instable ou qu'il ne risque pas de tomber. PELIGRO Verifique que el bastidor que alberga el instrumento está asegurado correctamente para evitar que pueda hacerse inestable o que caiga. DANGER Use safe lifting practices when moving the product. GEFAHR Beim Bewegen des Produktes ist auf eine sichere Hubtechnik zu achten. DANGER Utiliser des techniques de levage sûres pour déplacer le produit. PELIGRO Tenga mucho cuidado al levantar el producto para moverlo DANGER Mount the devices you install in a rack as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above. GEFAHR Montieren Sie die Geräte im Gestell so tief wie möglich. Platzieren Sie das schwerste Gerät ganz unten, während leichtere Geräte je nach Gewicht (je schwerer desto tiefer) darüber untergebracht werden. DANGER Montez les dispositifs que vous installez dans un bâti aussi bas que possible. Placez le dispositif le plus lourd en bas et le plus léger en haut, en plaçant tous les dispositifs progressivement de bas en haut du plus lourd au plus léger. PELIGRO Monte los instrumentos que instale en un bastidor lo más bajos posible. Ponga el instrumento más pesado en la parte inferior y los instrumentos progresivamente más livianos más arriba. Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 121 Cautions and Danger Notices Danger Notices DANGER When mounting the device under a fixed surface, under a desk, or under a shelf, mount the device with the bottom panel down and in a place where there is not much foot traffic. The fixed surface must be strong enough to withstand the weight of the device such that the device or the surface does not fall down. GEFAHR Wenn Sie das Gerät unter einer festen Oberfläche, einem Tisch oder einem Regal montieren, tun Sie dies mit der Unterseite nach unten und an einem Ort, an dem nicht viele Personen vorbeilaufen. Die feste Oberfläche muss stabil genug sein, um dem Gewicht des Geräts standzuhalten. DANGER Lors du montage de l’appareil sous une surface fixe (sous un bureau ou une étagère), installez l'appareil avec le panneau arrière pointé vers le bas et dans un endroit où il n'y a beaucoup de circulation piétonniaire. La surface fixe doit être suffisamment solide pour supporter le poids de l’appareil de telle sorte que ni l’apprareil ni la surface ne puissent tomber. PELIGRO Cuando instale el dispositivo debajo de una superficie fija, debajo de un escritorio, o debajo de un estante, hágalo con el panel inferior hacia abajo, en un lugar donde no se transite mucho. La superficie fija debe ser lo suficientemente fuerte como para soportar el peso del dispositivo, de modo que el dispositivo o la superficie no se desprendan. Laser dangers DANGER All fiber-optic interfaces use Class 1 lasers. GEFAHR Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1. DANGER Toutes les interfaces en fibre optique utilisent des lasers de classe 1. PELIGRO Todas las interfaces de fibra óptica utilizan láser de clase 1. DANGER Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do not comply with these standards might emit light that is hazardous to the eyes. GEFAHR Verwenden Sie nur optische Transceiver, die von Brocade Communications Systems zugelassen sind und die die Anforderungen gemäß FDA Class 1 Radiation Performance Standards in 21 CFR, Unterkapitel I, sowie IEC 60825 und EN60825 erfüllen. Optische Produkte, die diese Normen nicht erfüllen, können Strahlen aussenden, die für das menschliche Auge gefährlich sind. DANGER Utilisez uniquement des émetteurs-récepteurs optiques certifiés par Brocade Communications Systems, Inc. et conformes aux exigences sur la puissance de rayonnement de catégorie 1 de la FDA définies au sous-chapitre 21 CFR I et à les normes IEC 60825 et EN60825. Les produits optiques non-conformes à ces normes sont susceptibles d’émettre une lumière dangereuse pour les yeux. PELIGRO Utilice sólo transceptores ópticos aprobados por Brocade Communications Systems, Inc. y que cumplan con las normas IEC 60825 y EN60825, y con los estándares de rendimiento Clase 1 de FDA definidos en el subcapítulo I de 21 CFR. Los productos ópticos que no cumplan con estos estándares pueden emitir luz dañina para los ojos. 122 Ruckus ICX 7150 Switch Hardware Installation Guide Part Number: 53-1004928-05 © 2018 ARRIS Enterprises, LLC. All rights reserved. 350 West Java Dr. Sunnyvale, CA 94089. USA www.ruckuswireless.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Ruckus Networks Create Date : 2017:12:18 05:51:16Z Modify Date : 2017:12:21 09:55:16-08:00 Language : EN-US XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Ruckus Networks Title : Ruckus ICX 7150 Switch Hardware Installation Guide Creator Tool : AH XSL Formatter V6.4 R1 for Windows (x64) : 6.4.2.26942 (2016/12/07 15:30JST) Metadata Date : 2017:12:21 09:55:16-08:00 Producer : Antenna House PDF Output Library 6.4.928 (Windows (x64)) Trapped : False Document ID : uuid:e5810c5e-97ab-4cf3-aa6e-52f78a28fa9e Instance ID : uuid:5648953a-91b2-43bc-93c1-2b7476c0a08a Page Mode : UseOutlines Page Count : 123EXIF Metadata provided by EXIF.tools