SAFRAN Identity and Security MAVPDUAL Biometric Recognition Terminal User Manual DRAFT MA VP User Guide

SAFRAN MORPHO Biometric Recognition Terminal DRAFT MA VP User Guide

User Manual

Download: SAFRAN Identity and Security MAVPDUAL Biometric Recognition Terminal User Manual DRAFT MA VP User Guide
Mirror Download [FCC.gov]SAFRAN Identity and Security MAVPDUAL Biometric Recognition Terminal User Manual DRAFT MA VP User Guide
Document ID1445307
Application ID2kexpFXQp2no5fG2BELaqA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize324.18kB (4052202 bits)
Date Submitted2011-04-08 00:00:00
Date Available2011-04-08 00:00:00
Creation Date2011-03-10 09:57:26
Producing SoftwareGPL Ghostscript 9.0
Document Lastmod2011-03-10 09:57:26
Document TitleDRAFT_MA_VP_User_Guide
Document CreatorPDFCreator Version 1.2.0
Document Author: gt218377

MorphoAccess® VP Series
User Guide
Copyright© 2011 Morpho
Osny, France
MorphoAccess® VP Series - User Guide
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Warning
Warning
Copyright 2002-2011Morpho, All rights reserved.
Information in this document is subject to change without notice and does not
represent a commitment on the part of Morpho. No part of this document may be
reproduced or transmitted in any form or by any means, electronic or mechanical,
including photocopying or recording, for any purpose without the express written
permission of Morpho.
This legend is applicable to all pages of this document.
This manual makes reference to names and products that are trademarks of their
respective owners.
MorphoAccess® is a registered trademark of Morpho.
Made in France.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® VP Series - User Guide
Revision History
Revision History
The table below contains the history of changes made to the present document.
Version
Date
Description
01
January 11
Creation of the present document
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide

Dynamic (DHCP)
If it is not possible to use default network parameter values, then these values must be
modified. The easiest way to change network parameters is to use a USB Mass Storage
key.
The procedure is described in the Setting up IP parameters with a USB Mass Storage
Key section.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
28
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
Point to Point Ethernet Connection
The MorphoAccess® terminal can be connected directly to a PC by an Ethernet cable.
But there are some limits:
• if the PC Ethernet port doesn’t support the Auto-MDIX feature, then a crossover
Ethernet cable is mandatory. If no crossover Ethernet cable is available, then a
switch can be used (please refer to next section).
• If the PC to be used is already connected to a LAN, then it must be either
disconnected from the LAN, or equipped with a 2nd network interface board,
which will be dedicated to the connection with the terminal. It could be mandatory
to modify the network parameter of the PC: please contact your LAN
administrator to define the best solution.
Figure 11: Direct point to point Ethernet connection
29
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
Connection through only one Ethernet switch
The MorphoAccess® terminal can be connected to a PC through an Ethernet switch.
This is useful when no crossover cable is available, but instead, one Ethernet switch
and two Ethernet standard cables are available.
WARNING: an Ethernet HUB doesn’t allow a connection between two of its ports. An
Ethernet switch is really mandatory.
Figure 12: Connection, through an Ethernet switch
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
30
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
Connection through a LAN
Description
The MorphoAccess® terminal can be connected to a PC through a Local Area
Network (LAN).
The MorphoAccess® terminal required for a connection is specified by its IP address
or by its host name, if it can be added to the DNS Server database. The IP address is
either static, or dynamically assigned by the DHCP server of the network.
Figure 13: Connection through a LAN
It is recommended to connect MorphoAccess® terminals on a dedicated network to
reduce possible fraudulent accesses to terminal configuration. Please contact network
administrator for more information about LAN security strategies.
Before connecting the terminal to a LAN (through Ethernet), it is necessary to specify
the LAN parameters to the terminal. The values of these parameters are to be provided
and/or approved by the administrator of the network.
LAN with DNS Server
When a DNS server is available in the LAN, the PC can request the connection to the
MorphoAccess® terminal by using its host name instead of its IP address.
But the network administrator must add the MorphoAccess® terminal host name to the
DNS server database. Otherwise, a TCP open session request, using the terminal’s
hostname, will fail. Please contact local network administrator for this operation.
It is useful to specify the MorphoAccess® terminal by its host name, when the DHCP
mode is enabled, as the IP address of the terminal can change after a power up.
31
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
LAN without DNS Server
This section is about LAN without DNS Server, or with DNS Server but the
MorphoAccess® terminal host name cannot be added to the DNS Server base.
In that case the PC is not able to establish a connection with a MorphoAccess®
terminal using its host name. The IP address of the MorphoAccess® terminal is the
only way to specify the terminal.
It is not recommended to use the DHCP mode for normal operation, as the IP address
of the terminal can change after each power-up.
Static IP address (DHCP is off)
This is the easiest way to connect a terminal to a LAN: the IP address of the terminal
remains the same after each restart, and the Host System need only to know this IP
address to establish a connection with the terminal.
The IP address of the terminal must be reserved in the router by the network
administrator. Please contact the network administrator to require the value of the
network parameters listed below:
• The MorphoAccess® terminal IP address (one per terminal),
• gateway IP address,
• local subnet mask value.
Warning: if the MorphoAccess® terminal uses an IP address already assigned in the
network, the connection to the terminal will be instable.
Dynamic IP address (DHCP is on)
When the DHCP mode is activated in the terminal, at each power up the
MorphoAccess® terminal required an IP address to the network router. It could be the
same IP address as the one assigned before the power up, but it could also be different.
Please contact the network administrator to know if the LAN support DHCP mode.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
32
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
Setting up IP parameters with a USB Mass Storage Key
The IP configuration parameters can be set by using a USB mass storage key. No
wired connection with a PC is required. This operation requires a standard USB Mass
Storage key (FAT16 or FAT32 formatted, and 8 Gbyte maximum), and a dedicated PC
application: USB Network Configuration Tool.
This procedure is useful for MorphoAccess® terminals without keyboard and screen,
but is applicable also to MorphoAccess® terminals with keyboard and screen.
The procedure is detailed in the sections below, and in the MorphoAccess® USB
Network Tool User Guide document.
First step: build a configuration file on USB Mass Storage Key
Run the USB Network Configuration Tool application on a PC: an interface window
such as the one below is opened by the application.
Figure 14: USB Network Configuration Tool main window
Then insert the USB mass storage key into a free USB port of the PC.
33
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
First select either DHCP mode (IP address allocated dynamically), or static
mode
(static IP address).
• If the DHCP mode is selected, please specify terminal Host name in accordance
with network administrator
• If the DHCP mode is not selected, please specify terminal IP parameters (terminal
IP address, gateway IP address, sub network mask) provided by the network
administrator
The Terminal Serial
al Number value field is used only when SSL protocol is activated
on the terminal.
When all fields are filled with the data approved by the network administrator,
administrator click on
the Write File button. Then
select the root directory of the USB mass storage key.
After directory selection, the application creates a configuration file and an address
file.
Figure 15:: Build a setting file
f on a USB mass storage key
Second step: apply changes to the terminal
Remove the bottom cover of the MorphoAccess® VP Series terminal to give access to
the front USB port of the terminal.
Insure that the MorphoAccess® terminal is powered, and then insert
inser the USB Mass
Storage key with the configuration key.
key The terminal executes an internal process
which progress is indicated by audible and visible signals.
signals
At the end of the process, two medium-pitched
medium pitched "beeps" indicates that the USB mass
storage key can be removed. The terminal is then restarted, to apply the new values.
Figure 16:: Apply setting file to the MorphoAccess® terminal
Now, the terminal is ready to be connected to the network.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
34
MorphoAccess® VP Series - User Guide
Section 3: Connecting a MorphoAccess® to a PC
Wi-Fi™ Network configuration
Requirements
Wi-Fi™ connection is available under the following mandatory conditions:
• a Morpho Wi-Fi™ USB adapter must be plugged in the front USB port of the
terminal (the bottom cover must be removed to give access to this port). The
installation procedure is described in the MorphoAccess® VP Series Installation
Guide,
• a MorphoAccess® Wi-Fi™ license must be present in the terminal (as described
in Terminal license management section),
• the terminal must be disconnected from any wired network (it means no Ethernet
cable plugged) : Wi-Fi™ connection and Ethernet cable connection are mutually
exclusive,
After Wi-Fi™ license downloading and Wi-Fi™ USB adapter installation, make sure
to reboot the terminal by pressing the reset button (see paragraph Power supply
interface for more information on reset button).
NOTE: Both Wi-Fi™ USB adapter and license can be ordered under the reference
"MA WI-FI PACK".
Configuration
The Wi-Fi™ network configuration is described in the chapter 15 of the
MorphoAccess® Enrolment station User Guide document.
Wi-Fi™ troubleshooting
If the terminal is configured to use the Wi-Fi™ connection with the Wi-Fi™ USB
adapter plugged in and if there is no license present, the MorphoAccess® VP Series
terminal will display a 1-second red flash and will emit a short-low tone.
To solve this issue, unplug the Wi-Fi™ USB adapter and restart the terminal.
To restart the terminal use the reset button located in front face of the terminal (see
Power supply interface section for more information on reset button).
The Wi-Fi™ configuration parameters are described in the MorphoAccess®
Parameters Guide document.
35
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
Section 4: MorphoAccess® Terminal
Configuration
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
36
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
MorphoAccess® configuration parameters
Presentation
The name and the value of the MorphoAccess® terminal parameters (also named
"configuration keys") are located into different files composed of several sections, to
group configuration keys by affinity.
For example a file named "app.cfg" contains all the parameters defining the main
application settings, and the section “bio ctrl” contains the parameters related to the
biometric control.
The full name of a configuration key includes the file name and the section name, i.e.:
“file name/section name/key name”. Example: “app/bio ctrl/nb attempts”.
Please refer to MorphoAccess® Parameters Guide for the full description of all
configuration keys of a MorphoAccess® terminal.
Modifying the value of a parameter
There are two ways to modify the value of a terminal parameter:
• Remotely through an Ethernet or a Wi-Fi™ link, with a client application running
on the Host System (such as Configuration Tool or MATM applications).
• With a USB mass storage key, which contains a script prepared on a PC (for more
information see document MorphoAccess® USB Key encoder User Guide).
37
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
Configuring a connected MorphoAccess® terminal
Introduction
A MorphoAccess® terminal can be managed by a PC connected to the terminal, using
an application such as MEMS, Configuration Tool, MATM, or MorphoEnroll.
The remote operations available are mainly:
• Add a biometric record for a new user,
• Delete a biometric record for a removed user,
• Get Configuration parameter value,
• Modify the value of a configuration parameter
• Get Access control log file content,
• Change contactless card authentication keys
• Firmware upgrade.
• Add a license
The MorphoAccess® terminal works as a TCP/IP server, which waits for a request
from the Host System application, which acts as a TCP/IP client.
Figure 17: Configuration of a MorphoAccess® terminal by a Host System
The commands supported by the MorphoAccess® terminal are described in the
MorphoAccess® Host System Interface Specification document.
Date/Time settings
The date/time of the terminal can be initialized by a distant host system using an
application such as the "Configuration Tool" ("More" button) described below.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
38
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
Configuration Tool PC application
The Configuration Tool application is able to read and modify any MorphoAccess®
terminal parameter.
Figure 18: MorphoAccess® configuration tool main window
Please refer to MorphoAccess® Configuration Tool User Guide document for further
information about this PC application.
MATM PC application
The MATM application is another application able to read and modify the value of any
MorphoAccess® terminal parameter.
In addition to Configuration Tool application, the MATM application is able to
configure Wi-Fi™ parameters, and to activate SSL protocol.
For more information about this application, please refer to MorphoAccess® Terminal
Management User Guide document.
39
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
SSL securing
The TCP link used for remote management can be secured using SSL protocol. Please
refer to SSL Solution for MorphoAccess® document for further details.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
40
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
Upgrading the firmware
When required, the MorphoAccess® terminal firmware can be upgraded from a PC,
through an IP link (either Ethernet or Wi-Fi™) or using a USB mass storage key.
The last MorphoAccess® terminal firmware can be obtained on a CD/ROM package
from the customer service, or can be downloaded from Morpho Website dedicated to
biometric terminals:
http://www.biometric-terminals.com/
A login name and a password are required: it can be provided by the customer service:
hotline.biometrics@t.my-technicalsupport.com
Please refer to the MorphoAccess® Firmware Upgrade Guide document for more
information about firmware upgrade procedures.
41
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
MorphoAccess® terminal database management
Introduction
The management of the MorphoAccess® terminal internal biometric database can be
done remotely by an Enrolment Station, typically with a PC with MorphoEnroll
application, or with MEMS application, or with an application developed with
ActivMaci library.
The MEMS architecture allows managing the database of several MorphoAccess®
terminals from only one PC enrolment station.
The MorphoEnroll application is dedicated to manage only one MorphoAccess®
terminal database.
The management of the database (add/remove users) can be done using a USB mass
storage key as described in the MorphoAccess® USB encoder User Guide document.
Adding a user to the database
Adding a user means create a record with the biometric data of two fingers of the user,
and a unique identifier.
The MEMS application adds a user to its own database, and then it updates the
database of all MorphoAccess® terminals.
The MorphoEnroll application performs user enrollment directly on the
MorphoAccess® terminal: this application doesn’t manage any database on the PC.
Removing a user from the database
Removing a user means deleting the user’s record from the database of the
MorphoAccess® terminal.
The MEMS application is able to remove a user from a MorphoAccess® terminal
without removing it from its own base. But when the user’s record is removed from
MEMS database, it is automatically removed from the biometric database of all
MorphoAccess® terminals.
The MorphoEnroll deletes directly the user’s record from the MorphoAccess®
terminal: this application doesn’t manage any database on the PC.
Database Size
The MorphoAccess® VP Series terminal can store 5,000 user records in the local
database. This size can be extended to 10,000 user’s records by adding a specific
license (MA 10K USERS license). For each user, the terminal stores the biometric data
of two fingers.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
42
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
MorphoAccess® terminal license management
Definition of a license
A license unlocks the additional features of the MorphoAccess® terminal.
The MorphoAccess® VP Series terminal supports two licenses:
• MA 10K USERS,
• MA_WIFI.
The feature unlocked by each license is detailed in sections below.
MorphoAccess® MA 10K USERS license
By default, the MorphoAccess® VP Series terminal can match a fingerprint against a
database with a maximum of 5,000 user records (two fingerprints per user record).
The MA 10K USERS license extends MorphoAccess® VP Series recognition terminal
capabilities to a database with a maximum of 10,000 user records (2 fingerprints per
user record).
Warning: the database size is not dynamically modified by the license installation.
The license allows the creation of database with a higher size, but it doesn’t modify the
size of a already created database. The existing database must be deleted, and then
recreated with a higher size.
MorphoAccess® MA_WIFI license
The MA_WIFI license enables the Wi-Fi™ network (WLAN) optional feature.
Warning: The license alone is not enough, a USB Wi-Fi™ adapter compatible with
MorphoAccess® terminals is mandatory.
Adding a license in a MorphoAccess® terminal
To get a license, please contact our customer service.
The license is delivered in a file dedicated to only one MorphoAccess® terminal. Each
license file is generated for a unique serial number, and this is checked by the license
installation tool, at the beginning of installation process.
An Ethernet connection or a Wi-Fi™ link is mandatory for license installation.
Please refer to document MorphoAccess® Terminal License Management for more
information about license manager tool.
Checking terminal license in a MorphoAccess® terminal
The Licence Manager PC application is able to read the name of the licenses stored in
a MorphoAccess® terminal.
An Ethernet connection or a Wi-Fi™ link is mandatory for this operation.
43
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 4: MorphoAccess® Terminal Configuration
Please refer to document MorphoAccess® Terminal License Management for more
information).
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
44
MorphoAccess® VP Series - User Guide
Section 5: Access Control
Section 5: Access Control
45
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 5: Access Control
Access control presentation
Typical architecture of an access control system
Typical access control system architecture includes:
• one MorphoAccess® terminal per area to protect
• an Enrollment Station dedicated to user enrollment, and database synchronization
with all MorphoAccess® terminals (it could be a PC with MEMS application)
• a Central Security Controller : for area access final check, and physical access
command (open the door)
Figure 19: Typical access control system architecture
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
46
MorphoAccess® VP Series - User Guide
Section 5: Access Control
Typical access control process
1. All allowed user must be enrolled by the enrolment station. It means that the
enrolment station creates a record for each allowed user. This record includes the
biometric data of two of the user’s fingers.
2. When required, the Enrolment Station adds new user records into each
MorphoAccess® terminal, and removes obsolete user records.
3. When a user request the access to the area protected by the MorphoAccess®
terminal, the terminal checks user’s access rights using a biometric check.
4. If the result of the local access rights check is successful, a message is send to the
Central Security Controller for additional access rights check.
5. At the end of process, the Central Security Controller return a success signal to the
MorphoAccess® terminal, and an “open door” command to the door controller.
47
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 5: Access Control
MorphoAccess® terminal operating modes
Standalone mode or Slave mode
The MorphoAccess® terminal supports two exclusive operating modes:
• The Standalone Mode: the MorphoAccess® terminal manages the access control
alone, or with the help of a central access controller.
• The Proxy Mode: the access control application is located in a distant system
which drives the MorphoAccess® terminal as a slave device.
The Proxy mode is described in the Section 9 Proxy (or slave) Mode section.
The standalone mode is described in section below.
Standalone mode: Identification and/or Authentication
When in standalone mode, the MorphoAccess® terminal supports two main different
access control processes:
• The identification process, which starts when the user places his finger on the
biometric sensor. This process is described in the Section 6 Access control by
identification section.
• The authentication process, which starts with the presentation of a user’s
contactless card. Next step is the placement of user’s finger on the biometric
sensor. The terminal allows several authentication processes depending on the
location of the reference biometric data, and on the level of security required.
These processes are described in the Section 7 Access control by authentication
section.
The identification and the authentication processes can be activated simultaneously, as
described in Section 8: Multi-factor mode section.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
48
MorphoAccess® VP Series - User Guide
Section 5: Access Control
How to select the standalone access control process
The chart below describes the different processes available and the related
configuration keys.
Figure 20: Recognition mode synthesis
Identification and one authentication processes can be activated at the same time, as
described in Section 8: Multi-factor mode section.
49
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 5: Access Control
Access control result
Information for the user
The MorphoAccess® terminal communicates the result to the user, by a local audible
and visible signal. These signals are described in the Section 11 Man Machine
Interface section.
For example:
• When the access is granted, the terminal emits a green flash and a high pitched
note
• When the access is denied, the terminal emits a red flash and a low pitched note
Information for the administrator
The MorphoAccess® terminal creates a record for each access request, in a internal
log file, Each record contains the date and the time, the user’s identifier (if available),
and the result of the local access control check.
This feature is described in the Access request result log file section.
Integration in an access control system
At the end of the access rights control, the MorphoAccess® terminal is able to:
• Send a message, with data related to the access request, to a distant system which
could be a simple storing system, or a Central Security Controller. This feature is
described in the Sending the access control result to a distant system section.
• Wait for the answer of a distant system answer before emitting the result signal for
the user. This feature is described in the LED IN feature section.
• Activate an internal relay (if the access is granted to the user), as described in
Internal Relay activation on Access Granted result section.
The format of the messages (which include the user’s identifier) send to the distant
system is described in the MorphoAccess® Remote Messages Specification document.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
50
MorphoAccess® VP Series - User Guide
Section 5: Access Control
Access granted
Figure 21: Access control result = access granted
Access denied
Figure 22: Access control result = Access denied
51
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 6: Access Control by Identification
Section 6: Access Control by Identification
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
52
MorphoAccess® VP Series - User Guide
Section 6: Access Control by Identification
Identification mode description
Identification process
The identification process consists in retrieving the identity of an unknown person, by
comparison of a personal data with a base which contains the same type of personal
data of known persons. At the end of the process, the person is either identified
(identity found), or still unknown.
Access control by identification
The Identification process of the MorphoAccess® terminal proceed by comparison of
the biometric data of the finger placed on the biometric sensor, with the biometric data
of all the fingers stored in the database.
It means that the biometric data of the allowed users must be stored in the internal
database before they can request the access on the terminal. The biometric data of
allowed users are acquired by an enrolment station, with the same kind of biometric
sensor.
The access control by identification process is started when a finger is detected on the
biometric sensor
When the user requests the access, his identity is unknown, and it is the terminal that
searches for his identity. The terminal grants the access if a match is found (the user is
identified), otherwise the access is denied (the user remains unknown).
Result of the access control request
The result of the access right control is indicated by an audible and visible signal
emitted by the MorphoAccess® terminal itself. These signals are described on the
Access control result section.
User’s data required in the terminal
This mode requires that all authorized users must be enrolled in the internal database
of the terminal. It means that there is one record per authorized user: each user record
contains a unique identifier and the biometric data of two different fingers of the user.
The management of the internal database is described in the MorphoAccess® Database
management section.
53
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 6: Access Control by Identification
Compatibility with Access Control Systems
When the identification mode is activated, the MorphoAccess® terminal supports the
optional features listed below:
• Internal relay activation when the access is granted, as described in Internal Relay
activation on Access Granted result section
• External activation of the internal relay, as described in Internal Relay activation
by external button section
• Send access control result message to a remote system, as described in Sending
the access control result to a distant system section
• Wait for distant system confirmation before granting the access, as described in
LED IN feature section
Activation key
The Identification mode is enabled (and disabled) by only configuration key.
Activation of identification mode
app/bio ctrl/identification =1
Enabled
app/bio ctrl/identification = 0
Disabled
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
54
MorphoAccess® VP Series - User Guide
Section 6: Access Control by Identification
User Interface
In this mode, the MorphoAccess® terminal waits for the placement of a finger on the
biometric sensor. This state is displayed to the user by a specific signal, as described in
Terminal states section.
To request the access, the user places his finger on the biometric sensor: this action
starts the identification process.
Figure 23: Identification mode
The biometric data of the finger is captured, and then compared to all the biometric
data stored in the local database of the terminal.
• If a match is found, then the user is identified, and if there is no other access right
check, the access is granted to the user.
• Otherwise, if no match found, the user remains unknown (the user’s identifier is
unavailable), and the access is denied.
The result of the identification process is notified to the user by a specific signal, as
described in Terminal states section.
When the identification process is completed, whatever is the result (identified or not
identified), the terminal automatically restarts to the initial state: wait for finger
placement on the biometric sensor.
When there is no user stored in the database, the identification process is disabled. No
user (even an authorized user) is able to grant the access. The terminal notifies this
invalid state to the user, by emitting a specific signal, as described in Terminal states
section.
55
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Section 7: Access control by Authentication
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
56
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Authentication process
Introduction
The MorphoAccess® terminal offers an authentication mode designed to works with
contactless smart cards used as personal cards.
Then this section relates to only MorphoAccess® terminals equipped with a
contactless smartcard reader (see section Scope of the document).
In the whole document the word “card” means “contactless smart card”.
Authentication process
The authentication process consists in verifying the identity provided by a person, by
comparison of a personal data with the reference personal data of this person.
It means that at the beginning of the process, the person provides his identity and the
authentication process verify it. At the end of the process, the identity is either
confirmed (authenticated), or not confirmed (not authenticated).
This mode doesn’t compare the user’s data to the data of several users: it compare the
data provided by the user with the reference data provided by the same user during
enrollment phase.
Access control by authentication
To provide his identity, the user presents his personal identity card, which contains his
identifier. This action starts the authentication process.
Figure 24: Contactless card presentation starts authentication process
The user’s card must contain the user’s identifier and optionally the biometric data of
the user.
The terminal performs the required identity checks using the data read on the user’s
card, and if required, data stored in the internal database.
57
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
When it is required, the biometric check compares the biometric data of the finger
placed on the sensor with the reference biometric data of two fingers of the user,
acquired during enrollment process.
If a match is found, the result of the biometric check is positive: user’s identity is
confirmed. Otherwise, the result of the biometric check is negative: user’s identity is
not confirmed.
The access is granted only to authenticated users (user’s identity confirmed).
Authentication modes can be combined with a local identification in a multi-factor
mode, which is described in Section 8 Multi-factor mode section.
Data required on the user’s card
The MorphoAccess® terminal ignores contactless card encrypted with unknown
authentication keys. It means that the terminal starts the authentication process if the
user’s card is encrypted with the contactless authentication keys stored in the terminal.
The MorphoAccess® terminal rejects user’s cards without the data required by the
authentication process selected.
All authentication modes require the presence of the user’s identifier value. The other
data and the format of all the data required depends on the authentication mode
selected.
All non mandatory data found on the user’s card are ignored.
Please refer to the MorphoAccess® Contactless Card Specification document for more
information about contactless smartcard logical structure.
Authentication process options
The MorphoAccess® terminal offers several authentication processes, depending on
the user’s reference biometric data location, and the security level required.
The user’s reference biometric data can be located:
• Either on his personal card, as described in Biometric check, biometric data on
user’s card section
• Or in a record of the internal database, as described in Biometric check, biometric
data in local database
In addition, the biometric check can be disabled as specified in the section listed
below:
• Manual bypass of biometric control
• Automatic bypass of biometric control
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
58
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Manual bypass of biometric control
The default configuration of authentication mode requires a biometric control. But the
biometric check can be disabled by the MorphoAccess® terminal administrator. When
this is done, the MorphoAccess® terminal:
• doesn’t requires the user to place a finger on the biometric sensor
• grant the access without biometric check
According to the authentication process selected, the terminal:
• doesn’t performs any check on the user’s identifier, as described in section No
biometric check, no user id check
Automatic bypass of biometric control
The MorphoAccess® terminal offers an authentication mode which depends on the
user’s card content.
When the MorphoAccess® terminal detects a user’s card, it searches for a specific data
which indicates, if the biometric check is either mandatory or disabled.
This authentication mode is described in section Authentication process specified by
User’s card.
Result of access control check
The result of the access control check is signified to the user by local audible and
visible signals, as described in Access control result section.
Compatibility with Access Control Systems
When the identification mode is activated, the MorphoAccess® terminal supports the
features listed below:
• Internal relay activation when the access is granted, as described in Internal Relay
activation on Access Granted result section
• External activation of the internal relay, as described in Internal Relay activation
by external button section
• Send access control result message to a remote system, as described in Sending
the access control result to a distant system section
• Wait for distant system confirmation before granting the access, as described in
LED IN feature section
59
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Selection of user’s contactless card type (MIFARE™ or DESFire™)
Contactless Card type
As MorphoAccess® terminals are equipped with a contactless smartcard reader
compatible with MIFARE™ and DESFire™ cards (see section Scope of the
document), it is possible to specify the type of card to be supported by the terminal:
• Only MIFARE™ cards: for example when the terminal replaces a
MorphoAccess® 120 terminal.
• MIFARE™ and DESFire™ cards: for example during a transition phase between
MIFARE™ cards only to DESFire™ cards only
• DESFire™ cards only
Configuration key
The type of contactless smartcard enabled is defined by the following specific
configuration key:
Type of contactless smartcard enabled
app/contactless/enabled profiles = 0
MIFARE™ cards only (support binary format
for user’s identifier)
app/contactless/enabled profiles = 1
DESFire™ cards only (TLV format only)
app/contactless/enabled profiles = 2
MIFARE™ cards only (TLV format only)
app/contactless/enabled profiles = 3
MIFARE™ and DESFire™ cards (TLV
format only)
Compatibility with Authentication modes
Using a binary value read on the card as user’s identifier is allowed only with
MIFARE™ smart card, and when the “app/contactless/enabled profiles” configuration
key is set to 0 (zero).
All other values of this configuration keys requires TLV formatted data, as described
in the MorphoAccess® Contactless Card Specification document.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
60
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Biometric check, biometric data on user’s card
Description
In this mode, each user's card contains an identifier and the biometric data of two
different fingers of the user. The terminal compares the biometric data of the finger
placed on the biometric sensor, with the biometric data found on the user’s card. If a
match is found, the access is granted, otherwise the access is denied.
This authentication mode doesn’t use the internal database of the terminal.
If required, the biometric check can be disabled, as described in the No biometric
check, no user id check section.
User’s data required in the terminal
This authentication mode doesn’t use the internal database of the MorphoAccess®
terminal. None user’s personal data is required in the terminal.
User’s data required on the user’s card
To be compatible with this authentication mode, the user’s card must contain:
• the user’s identifier (User ID)
• the biometric data of two reference fingers of the user.
All other data are ignored.
The data on the card must comply with the TLV format, as described in the
MorphoAccess® Contactless Card Specification document.
Activation key
This mode is activated by only one configuration key.
Authentication mode with biometric data check and biometric data stored on
user’s card.
61
app/bio ctrl/authent PK contactless = 1
Enabled
app/bio ctrl/authent PK contactless = 0
Disabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
User interface
The authentication process starts when the user presents his contactless card in front of
the terminal. If the terminal found the required data on the user’s card, then the user is
invited to place his finger on the biometric sensor, for biometric authentication.
Figure 25: Authentication with user's fingerprints on contactless card
The terminal compares the biometric data of the finger placed on the sensor, with the
reference biometric data of the two reference fingers read on user's card.
The authentication process is successful (identity confirmed) if the captured finger data
matches with one of the two references finger data. Otherwise, if no match is found,
the authentication process fails (identity not confirmed).
The result of the authentication process is notified to the user by a specific signal, as
described in Terminal states section.
When the authentication process is completed, whatever is the result (identity
confirmed or not), the terminal automatically restarts to the initial state: wait for
another user’s card presentation.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
62
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Biometric check, biometric data in local database
Description
In this mode, each user's card contains only an identifier. The biometric data of two
different fingers of the user are stored in the internal database, with the same user’s
identifier as the one on the user’s card.
The terminal compares the biometric data of the finger placed on the biometric sensor,
with the user’s biometric data found in the database. If a match is found, the access is
granted, otherwise (no match found) the access is denied.
User’s data required in the terminal
This authentication mode requires the creation of a record for each allowed user. Each
record contains:
• The same user’s identifier value as the one stored on user’s card
• The biometric data of two user’s fingers
If the user’s identifier read on the user’s card, is not found in the database, then the
access denied.
The size and the management of the MorphoAccess® terminal internal database is
described in MorphoAccess® Terminal Database management section.
User’s data required on card
The only data required on the user’s card is the user’s identifier. All other data is
ignored.
The terminal is able to read the user’s identifier either stored according to TLV format
or to be read directly at a given offset on the card (binary format).
The TLV format is described in the MorphoAccess® Contactless Card Specification
document.
Activation key
The configuration key below is used to activate the authentication mode with user’s
reference biometric data stored in database.
Authentication with biometric data stored in the database
63
app/bio ctrl/authent ID contactless = 0
Disabled
app/bio ctrl/authent ID contactless = 1
Enabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
User Interface
The authentication process starts when the user presents his contactless card in front of
the terminal. If the terminal found the required data on the user’s card (the user’s
identifier), it search for the user’s record, in the internal database. Then the user is
invited to place his finger on the biometric sensor, for biometric authentication
Figure 26: Authentication with biometric check and database
The authentication process is successful (identity confirmed) if the captured finger data
matches with one of the two references finger data. Otherwise (no match found) the
authentication process fails (identity not confirmed).
The result of the authentication process is notified to the user by a specific signal, as
described in Terminal states section.
When the authentication process is completed, whatever is the result (identity
confirmed or not), the terminal automatically restarts to the initial state: wait for
another user’s card presentation.
When there is no user stored in the database, this authentication process is disabled. No
user (even an authorized user) is able to grant the access by this way. The terminal
notifies this invalid state to the user, by emitting a specific signal, as described in
Terminal states section.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
64
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
No biometric check, no user id check
Description
This authentication mode is the version of the “Biometric check, biometric data on
user’s card authentication mode with biometric check disabled.
The terminal searched only for the user’s identifier on the user’s card. No other check
is performed : the user’s identifier is not searched in the local database, and there is no
biometric check.
The MorphoAccess® terminal acts as a simple contactless card reader.
The access is granted only if the user’s card is encrypted with the authentication keys
stored in the terminal, and if the terminal is able to read a user’s identifier. Otherwise,
the card is ignored and the access denied.
User’s data required in the terminal
In this authentication mode, the internal database of the MorphoAccess® terminal is
not used.
User’s data required on the user’s card
The user’s identifier (User ID) is the only one data required on the user’s record, all
other data are ignored.
The terminal is able to read the user’s identifier either stored according to TLV format
or to be read directly at a given offset on the card (binary format).
The TLV format is described in the MorphoAccess® Contactless Card Specification
documents.
The MorphoAccess® terminal doesn’t perform any check on the value of the user’s
identifier.
Activation keys
This mode is activated with two configuration keys.
Authentication process without biometric check and without User ID search in
database
65
app/bio ctrl/authent PK contactless = 1
Enabled
app/bio ctrl/bypass authentication = 1
Enabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
User Interface
The authentication process starts when the user presents his contactless card in front of
the terminal.
Figure 27: Authentication without biometric check, and without User ID check
The authentication process succeeds if the user’s identifier is found. Otherwise, the
authentication process fails.
The result of the authentication process is notified to the user by a specific signal, as
described in Terminal states section.
When the authentication process is completed, whatever is the result (identity
confirmed or not), the terminal automatically restarts to the initial state: wait for
another user’s card presentation.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
66
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
No biometric check, but User ID check
Description
This authentication mode is the version of the “Biometric check, biometric data in
local database” authentication mode, when biometric check is disabled.
The user’s identifier is the only data read on user’s card. The MorphoAccess®
terminal checks if the user’s identifier exists in the database.
The access is granted if the user’s identifier read on the user’s card is found in the
internal database. Otherwise (user’s identifier not found in the database), the access is
denied.
User’s data required in the terminal
This mode requires a local database, and a record must be created for each allowed
user. Each record contains:
• The same identifier as the one on the user’s card
• The reference biometric data of two fingers of the user.
If the terminal doesn’t found a record with the user’s identifier read on the card, the
access is denied.
The size and the management of the MorphoAccess® terminal internal database is
described in MorphoAccess® Terminal Database management section.
User’s data required on the user’s card
The only data required on the user’s card is the user’s identifier.
The terminal is able to read the user’s identifier either stored according to TLV format
or to be read directly at a given offset on the card (binary format).
All other data found on the card is ignored.
Contactless smartcard logical structure is described in MorphoAccess® Contactless
Card Specification document.
Activation keys
This function requires several configuration keys.
Authentication process without biometric check, but User ID is searched in database
67
app/bio ctrl/authent ID contactless = 1
Enabled
app/bio ctrl/bypass authentication = 1
Enabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
User Interface
The authentication process starts when the user presents his contactless card in front of
the terminal.
Figure 28: Authentication without biometric check, and without User ID check
The user’s identifier is read on the user’s card and searched in the local database.
The authentication process succeeds if the user’s identifier is found in the local
database. Otherwise, the authentication process fails.
The result of the authentication process is notified to the user by a specific signal, as
described in Terminal states section.
Once the authentication process is completed, the terminal automatically loops back
and waits for another user’s card presentation.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
68
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Authentication process specified by User’s card
Description
When this mode is enabled, the access rights check to perform is specified by a
dedicated data on user’s card. It means that the same terminal can execute a different
process according to a data found on the user’s card:
• Either the biometric check is performed with the reference biometric data found
on user’s card
• Or the biometric check is disabled, and only the presence of the user’s identifier
on the user’s card is checked
A card which disables the biometric control is useful when the biometric data capture
is not required (for a short period visitor for example), or impossible (physically or
legally). This kind of cards can be realized without user’s presence and the same card
used for different visitors.
The internal database of the MorphoAccess® terminal is not used.
User’s data required in the terminal
This authentication mode doesn’t use the internal database. There is no personal data
stored in the terminal.
User’s data required on the user’s card
To be compatible with this mode, the user’s card must contain the user’s identifier and
the process selector.
If the biometric check is requested, the biometric data of two fingers of the user must
be present on the user’s card.
All other data are ignored.
The required data must be stored according to TLV format.
Contactless smartcard logical structure is described in MorphoAccess® Contactless
Card Specification document.
Activation key
This mode is activated and deactivated by only one configuration key.
Authentication process defined by user’s contactless card
69
app/bio ctrl/authent card mode =1
Enabled
app/bio ctrl/authent card mode = 0
Disabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
User Interface
Start
The authentication process starts when the user presents his contactless card in front of
the MorphoAccess® terminal.
The terminal searches on the user’s card, for the data that indicates if the biometric
check is mandatory or disabled. If this data is found, the terminal executes the required
process.
Figure 29: Authentication process specified by user's card
Biometric check mandatory
The terminal requires the user to place a finger on the biometric sensor. Then it
executes a biometric comparison of the finger placed on the sensor and the reference
biometric data read on user’s card.
The process is identical to the one described in Biometric check, biometric data on
user’s card section.
Biometric check disabled
The result of the authentication process is positive (identity confirmed), if the user’s
identifier is found on the user’s card.
The terminal doesn’t require the user to place a finger on the biometric sensor, and
doesn’t perform any biometric check.
The process executed in identical to the one described in No biometric check, no user
id check.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
70
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Allowed format for User’s identifier
TLV structured data
The user’s identifier is stored in ASCII within a TLV structure.
User’s identifier stored in TLV format
app/contactless/data format = 0
TLV structure
app/contactless/data length=0.0
Automatic size
app/contactless/data offset= 0.0
Automatic offset
The data written on user’s card by MEMS application, and by MorphoAccess® 500
Series terminals enrolment embedded application, are TLV formatted.
The contactless smartcard logical structure is described in a dedicated document:
MorphoAccess® Contactless Card Specification.
71
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
ISO14443 type A UID
Description
The MorphoAccess® terminal is able to use the ISO 14443 type A Card UID, as user’s
identifier.
This Card UID is available from any MIFARE™ cards and from any DESFire™
cards.
The Card UID can be read either in most significant byte first (MSB) order, or in less
significant byte (LSB) order.
Card type compatibility
This format can be only used only with the “MIFARE™ only default mode”.
Type of contactless smartcard enabled
app/contactless/enabled profiles = 0
MIFARE™ only (support binary
user’s identifier)
When the key value is 0, the terminal is able to get the card UID of MIFARE™ cards
and DESFire™ cards.
Configuration keys
A configuration key specifies on which kind of identifier the access rights are
assigned. To use Card UID, the CARDDATA tag must be removed, and the
CARDSN:STD or the CARDSN:REV must be added.
app/ bio ctrl/AC_ID
CARDDATA
TLV structure: must be removed
CARDSN:STD
ISO14443 type A UID, MSB order.
The card UID 0xFEA7B152 value
gives a user’s identifier equal to
4272402770
CARDSN:REV
ISO14443 type A UID, LSB order.
The card UID 0xFEA7B152 value
gives a user’s identifier equal to
1387374590.
Another configuration key specifies which kind of user’s identifier starts the access
control process.
Data use for access control request
app/contactless/ event on = 1
SSE-0000082427-01
January 2011
ISO 14443 type A Card UID (Unique
IDentifier)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
72
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
Binary data
Description
The MorphoAccess® terminal is able to use as user’s identified, a binary value to read
on specific location on user’s card.
This binary value could be the serial number of the card, as explained in the Example:
MIFARE™ card Serial Number used as user’s identifier section.
The MorphoAccess® terminal is able to read a binary value which is not aligned on
complete bytes. This ability is useful to extract the user’s identifier from a Wiegand
frame written on the user’s card. A sample is described in Example: 32 bits user’s
identifier within a 37-bits Wiegand frame section.
No TLV structure is required on user’s card: the MorphoAccess® terminal is able to
use user’s cards written by other systems.
Card type compatibility
This format can be only used only with the “MIFARE™ only default mode”.
Type of contactless smartcard enabled
app/contactless/enabled profiles = 0
MIFARE™ only (support binary
user’s identifier)
Configuration keys
The binary data to read is data defined by:
• The offset of the first block which contains the data
• The offset of the first byte/bit of the data, within the sector (15 bytes maximum).
The terminal is able to read a user’s identifier which offset is different from a
multiple of 8 bits.
• The length (in bytes and bits) of the data (8 bytes maximum). The terminal is able
to read a user’s identifier which length is different from a multiple of 8 bits.
• The read direction (MSB or LSB)
User’s identifier stored in ASCII format
73
app/contactless/dataformat = 1
Binary format
app/contactless/B
[1-215] First block to read on card
app/contactless/data length [number of
bytes].[additional bits]
User ID length in bytes and additional
bits (8 bytes maximum)
app/contactless/data offset [number of
Location of first byte/bit of the user’s
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
bytes].[additional bits]
identifier (15 bytes maximum)
app/contactless/data type
Byte read acquisition method: either
little or big endian.
0.1 (binary data, MSB first)
0.0 (binary data, LSB first)
Example: MIFARE™ card Serial Number used as user’s identifier
In this sample the terminal read the first four byte, in MSB direction, of the first sector
of the MIFARE™ card which contains the serial number of the card.
If bytes to read are F4 E1 65 34, then the user identifier value is "4108412212"
(ASCII).
Activation of identification mode
app/contactless/data format= 1
Binary format
app/contactless/data type= 0.1
Binary MSB format
app/contactless/data length = 4.0
Size = 4 bytes, no additional bit
app/contactless/data offset= 0.0
First byte of the block
app/contactless/B= 1
First block of the card
Example: 32 bits user’s identifier within a 37-bits Wiegand frame
The user’s card contains,
contains at the first block of sector 15 a full 37 bits Wiegand frame
(which includes start and stop bits, the site code of the sender,, and user’s identifier).
identifier
Figure 30 : Sample
ample of user’s identifier which is included in a Wiegand frame
The 32 bits identifier begins at bit four. It is located after the start bit (bit0) and the site
code (bit1-2-3).
3). The first block of sector #15 is block #46.
Acquisition of a 32 bits user’s identifier inside a 37 bits Wiegand frame.
frame
app/contactless/data format= 1
Binary format
app/contactless/data type= 0.1
Binary identifier, MSB format
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
74
MorphoAccess® VP Series - User Guide
Section 7: Access control by Authentication
app/contactless/data length = 4.0
Size = 4 bytes
app/contactless/data offset = 0.4
User’s identifier begins at bit 4 of the
first byte of the block specified below
app/contactless/B = 46
Read at block #46 (first block of
sector #15)
It is possible to configure the MorphoAccess® terminal to add automatically the start
and stop bits to the Wiegand output frame, if the user’s identifier must be send to a
distant system using Wiegand protocol.
75
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 8: Multi-factor mode
Section 8: Multi-factor mode
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
76
MorphoAccess® VP Series - User Guide
Section 8: Multi-factor mode
Multi-factor mode
Description
When the identification mode and one of the contactless card authentication modes are
activated, then the terminal is in “multi-factor” mode.
User Interface
It means that the user is allowed to choose the access right control to be processed by
the terminal:
• If the user places his finger first on the sensor, then it is identification process
which is executed.
• If the user presents his contactless card first, then it is authentication process
which is executed.
Figure 31: Multi-factor mode (identification and authentication)
When there is no database, the identification mode is disabled, but the authentication
mode is still available.
User’s data required in the terminal
The requirements of the Identification mode and the requirements of the selected
authentication mode apply to le multi-factor modes.
User’s data required on the user’s card
The items required on the user’s card depend on the authentication mode(s) activated.
Please refer to the appropriate section for further details.
Activation keys
This mode is activated by enabling identification mode, and one of the authentication
modes with contactless card.
77
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 8: Multi-factor mode
Activation of multi-factor mode
app/bio ctrl/identification =1
Enabled
app/bio ctrl/authent card mode = 1
or
app/bio ctrl/authent ID contactless = 1
or
app/bio ctrl/authent PK contactless = 1
Enabled
SSE-0000082427-01
January 2011
Enabled
Enabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
78
MorphoAccess® VP Series - User Guide
Section 9: Proxy (or slave) Mode
Section 9: Proxy (or slave) Mode
79
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 9: Proxy (or slave) Mode
Description
Scope
The Proxy mode is an operating mode where the access control main application is
located in a distant system. This is not a standalone mode like Identification and
Authentication modes.
It means that the terminal becomes a slave of the host system application. The access
control application is running on the host system and used MorphoAccess® terminal
high level functions:
• Identification function
• Authentication function
• Read data on a contactless card
• Access control result signal command
Figure 32: Proxy (slave) mode
The MorphoAccess® VP Series terminal is driven through an Ethernet (or Wi-Fi™)
link using TCP or SSL protocol.
The MorphoAccess® terminal acts as a server: it is either waiting for a command or
executing a command.
The commands allowed by the MorphoAccess® terminal are described in the
MorphoAccess® Host System Interface Specification document.
For further details about SSL on the MorphoAccess® terminal, please refer to the SSL
Solution for MorphoAccess® documentation.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
80
MorphoAccess® VP Series - User Guide
Section 9: Proxy (or slave) Mode
Local signals
When the terminal is waiting for a command from the distant system, there is none
local signal: the status LED is off, the sensor backlight is off, the buzzer is off.
But when a command is in progress the terminal emits the signals related to the
function. It is the same signals as the standalone modes.
It means, for example, that:
• When the Identify command is in progress, the terminal displays the same signals
as the standalone Identification mode.
• When the terminal receives the “access granted” command from the distant
system, it emits the “access granted” signal as described in the Access control
result section.
The local signals are described in the Section 12 MorphoAccess® VP Series terminal
sound and light Interface section.
Proxy mode use sample
The sample below described a typical exchange between the terminal and the distant
system for a basic access control by identification driven by the distant system.
Figure 33: PROXY sample with a remote Identification process
81
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 9: Proxy (or slave) Mode
Proxy mode activation
The proxy mode is automatically enabled when the identification mode and all
authentication modes are disabled.
Proxy mode (all local standalone access control application are inhibited)
app/bio ctrl/identification = 0
Disabled
app/bio ctrl/authent card mode = 0
Disabled
app/bio ctrl/authent PK contactless = 0
Disabled
app/bio ctrl/authent ID contactless = 0
Disabled
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
82
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Section 10: MorphoAccess® Terminal
Customization
83
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Number of biometric check attempts
Description
In order to reduce the False Rejection Rare, the terminal allows the user to place again
his finger on the sensor for a 2nd try, when the initial biometric check fails.
This 2nd try is allowed by default, but can be disabled.
The 2nd try allows the user to upgrade the finger placement, or to place another finger.
In addition, and also to reduce the FRR, during this 2nd try, the terminal executes a
more powerful biometric check (which is also little bit slower).
Configuration key
By default, the two attempts mode is activated, but can be disabled.
Setting up the number of biometric check attempts
app/bio ctrl/nb attempts = 1
Only one, no retry allowed
app/bio ctrl/nb attempts = 2
Two, one 2nd try is allowed (default)
Identification mode
If the finger of the user is not recognized, he has 5 seconds to place again one of his
fingers on the sensor. If a finger is placed on the sensor after this delay, then the
terminal process it as a new access request.
The value of this delay is defined by a dedicated configuration key.
setting up the identification timeout
app/bio ctrl/identification timeout
5 (1-60)
Authentication mode
In authentication mode, if the user place on a sensor a finger which is not recognized,
then the terminal request him to replace his finger without presenting his card again.
The result is sent only after this second attempt.
The wait delay for a finger on the sensor is specified by one configuration key.
Setting up the authentication timeout (seconds)
app/bio ctrl/authent timeout
SSE-0000082427-01
January 2011
10 (1-60)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
84
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Setting up matching threshold
Description
The performances of a biometric system are mainly characterized by two values:
• The False Reject Ratio (FRR) : number of wrongly rejected allowed users, divided
by the number of access requests
• The False Acceptance Ratio (FAR) : number of wrongly admitted not allowed
users, divided by the number of access requests
Both ratio values are linked. Different trade-offs are possible between FRR and FAR
depending on the security level targeted. When convenience is the most important
factor, the FAR must be low and conversely if security is more important, then the
FAR has to be minimized.
Different tunings are proposed in the MorphoAccess® terminal depending on the
security level targeted by the access control system.
Configuration key
The False Acceptance Ratio is tuned indirectly by a configuration key: the highest is
the configuration key value; the lower is the FRR value.
Setting up the matching threshold
bio/bio ctrl/matching th
85
3 (1-10)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Matching threshold values are detailed in the table below:
Value
FAR value
Lowest threshold value: the number of false rejects is very low, but
the number of false acceptances is too high for a secure usage.
It is strongly advised to don’t use this value, because the terminal
becomes too tolerant.
FAR < 1 %
FAR < 0.5 %
FAR < 0.1%
Recommended value for physical access control application
FAR < 0.05 %
FAR < 0.01 %
Recommended value for logical access control application
FAR < 0.001 %
FAR < 0.0001 %
FAR < 0.00001 %
FAR < 0.0000001 %
10
Highest threshold value: the number of false acceptance is very
low, but the number of false rejections is too high for the comfort
of users.
It is strongly advised to don’t use this value, because the terminal
becomes too restrictive.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
86
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Anti-tamper and anti-pulling switches
Description
The MorphoAccess® VP Series terminal is able to detect two kinds of unusual events:
• the front glass is removed, by monitoring anti-tamper switches
• the terminal is removed from the wall, by monitoring the anti-pulling switches
When one of those events is detected, the MorphoAccess® VP Series terminal acts as
required by the related configuration key (see section below):
• Ignore the event (default) : useful during normal maintenance operations
• Send an alarm message to a distant system through the channel already used by
the access control result messages (see Sending the access control result to a
distant system section).
• Emits a local audible and visual signal (see Terminal states section)
The format of the alarm message is described in the MorphoAccess® Remote
Messages Specification document.
Figure 34: Anti-pulling switches
Figure 35: Anti-tamper switches
87
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Please refer to the MorphoAccess® VP Series Installation Guide for more information
about the anti-tamper and the anti-pulling switches.
Configuration keys
The action(s) to be performed by the MorphoAccess® terminal is defined by a unique
dedicated configuration key.
Tamper alarm level
app/tamper alarm/level = 0
Disabled: Anti-pulling and anti-tamper switches are
ignored (default)
app/tamper alarm/level = 1
Silent message only: an alarm message is sent to a
distant system.
app/tamper alarm/level = 2
Silent message and local alarm signal: in addition
to previous level (1), the terminal buzzer emits an
audible and visible alarm signal
The alarm message is sent through the same channel as the “access control result”
message. Then, if there is no channel defined for the result message, the alarm
message is not sent. Please refer to Sending the access control result to a distant system
section.
In addition if the alarm message is to be sent through the serial port using Wiegand or
DataClock protocol, it is mandatory to:
• Enable the sending of error messages.
• Change the error code of the message is default value cannot be used
Allows the sending of error messages (DataClock/Wiegand protocol)
app/failure ID/enabled=1
Enables error message
Anti-pulling or anti-tamper alarm message identifier (Wiegand or DataClock)
app/failure ID/alarm ID
SSE-0000082427-01
January 2011
65535 (0 – 65535)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
88
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Example 1: send alarm message in Wiegand, and output local alarm signal
In case of anti-tamper or anti-pulling detection, the terminal must:
• Send an alarm message to a distant system, using Wiegand protocol. The identifier
(error code) of the alarm message is 62221.
• Emit a local alarm signal.
Send an alarm message in UDP quietly in case of intrusion detection
app/tamper alarm/level = 2
Anti-pulling or anti-tamper: the
terminal output a local alarm signal and
send an alarm message to a distant
system
app/failure ID/alarm ID = 62221
The identifier of alarm message is
62221.
app/failure ID/enabled = 1
Error and alarm messages are allowed
while using Wiegand or DataClock
protocols.
app/send ID wiegand/enabled = 1
Enables to send message though serial
channel using Wiegand protocol.
Example 2: send an alarm message in UDP (no local alarm signal).
In case of anti-tamper or anti-pulling detection, the terminal should send an alarm
message to a distant system, through Ethernet (or Wi-Fi™), using UDP protocol. No
local alarm signal is required.
Send an alarm message in UDP in case of anti-pulling or anti-tamper detection
89
app/tamper alarm/level = 1
Anti-tamper or anti-pulling : send an
alarm message to a distant system only
(no alarm signal emitted by the
terminal)
app/send ID UDP/enabled =1
Enables message sending though
Ethernet (or Wi-Fi™) channel using
UDP protocol.
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 10: MorphoAccess® Terminal Customization
Multimodal Security level
Description
The MorphoAccess® VP Series terminals allow to select the security level of the
multimodal biometrics.
Configuration key
The multimodal biometrics security level is selected by only one configuration key.
Multimodal biometrics security level
app/bio ctrl/security level = 0
Standard security level (default value)
app/bio ctrl/security level = 1
High security level.
To be use to increase the protection
against fraud (but it may affect the FRR
and response time)
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
90
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Section 11: Compatibility with an Access Control
System
91
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Internal Relay activation on Access Granted result
Description
If the result of the access rights check is successful, the internal relay may be
optionally activated, for example, to directly trigger a door switch.
The duration of the activation of the internal relay can be modified by a specific
configuration key.
Access control installation using internal relay offers a lower security level, than an
installation with a central access controller which is the only one allowed opening the
door.
Figure 36: MorphoAccess® terminal internal relay
Activation key
A configuration key enables internal relay activation on access granted.
Relay activation when access is granted
app/relay/enabled = 0
Enabled
app/relay/enabled = 1
Disabled
Configuration keys
The relay aperture time can be defined by a specific configuration key (300 means 3
seconds).
Relay aperture time in 10 ms
app/relay/aperture time in 10 ms
SSE-0000082427-01
January 2011
300 (50 to 60000)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
92
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
The default state of the relay can also be defined.
Relay default state
93
app/relay/relay default state = 0
Open (default)
app/relay/relay default state =1
Close
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Internal Relay activation by external button
Description
This feature enables to activate the internal relay of the MorphoAccess® terminal
using the LED1 signal input, in addition to normal activation on access granted result.
It means either a successful recognition or a signal on LED1 activate the internal relay.
A typical application of this feature is to open the door from inside an area protected
by a MorphoAccess® terminal (as described in figure below).
• To enter in the building the user must be successfully recognized by the
MorphoAccess® terminal
• A simple push-button connected to LED1 between LED1 and GND wires of the
MorphoAccess® terminal will trigger the door to leave the building.
Figure 37: Activation of internal relay by an external button (sample)
Activation key
A specific configuration key enables this feature.
MorphoAccess® terminal relay is controlled by LED1 input
app/relay/external control by LED1 = 0
Disabled (default)
app/relay/external control by LED1 =1
Enabled
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
94
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Access request result log file
Description
When enabled, the terminal creates a record for each access request in a local log file.
Each record includes:
• the date and the time of record creation (when access control result is known),
• the user’s identifier (if available)
• the access control process executed (Identification, Authentication with biometric
check, ..)
• the result of the access control (granted or denied, and if denied for which reason),
• And other data used for statistical reasons
The format of a log record is described in the MorphoAccess® Host System Interface
Specification document.
Log File management
Three commands are available for log file management:
• A command which return the current status of the log feature (enabled/disabled,
number of records)
• A command which returns the content of the log file
• A command that delete the log file
For more information about these commands, refer to the MorphoAccess® Host
System Interface Specification document.
Log File size
The capacity of the log file is 8 000 records.
When the log file is full, the terminal automatically stops the addition of new records,
but new access requests are allowed.
If requested by the specific configuration keys, the terminal can sent a “log file full”
warning message to a distant system.
The format of the “Log file full warning” message is described in the MorphoAccess®
Remote Messages Specification document.
95
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Activation key
The creation of a record for each access request is enabled (and disabled), by only one
configuration key.
Enabling recording of all access request results in the internal log file
app/log file/enabled = 1
Enabled
app/log file/enabled = 0
Disabled
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
96
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Sending the access control result to a distant system
Presentation
After access control rights check, the MorphoAccess® terminal can send a message
which contains the result of the control, to a distant device (such as a Central Security
Controller). The MorphoAccess® terminal is able to use different channels and
different protocols, to send this message.
This message can be used, for instance, to log the access request or to perform
additional access rights check. It depends on the role of the distant device in the global
access control system.
Figure 38: Sending access control result message to a distant system
Please refer to MorphoAccess® Remote Messages Specification for more information
about the format and the protocol of the access control result messages.
The LED IN feature enables to expect a positive answer from the distant system before
granting the access.
Available ports and protocols
The MorphoAccess® VP Series terminal is able to send the access control result
messages to a distant system, using the following ports and protocols:
• serial port : Wiegand or DataClock, or RS485
• Ethernet link or Wi-Fi™ link: TCP or UDP or SSL
This is detailed in the next sections.
Serial port (output only)
Protocol selection
There is only one serial port, and then only one protocol can be used. It must be one of
these protocols: Wiegand or DataClock or RS485.
97
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Wiegand protocol
The Wiegand frame includes only the user identifier (which must be a numeric value).
By default, the access control result message is sent only when the user is identified or
authenticated.
But as an option this access control result message can be sent when the access is
denied, but with a numeric error code instead of the user identifier value.
The sending of the message through the serial port, using DataClock protocol is
conditioned only one configuration keys.
Send access control result message using Wiegand protocol on serial output port
app/send ID wiegand/enabled = 1
Enabled
app/send ID wiegand/enabled = 0
Disabled
The format of the Wiegand frame is defined by several configuration keys.
DataClock protocol
Same comment as for Wiegand protocol.
The sending of the message through the serial port, using DataClock protocol is
conditioned only one configuration keys.
Send access control result message using DataClock protocol on serial output
port
app/send ID dataclock /enabled = 1
Enabled
app/send ID dataclock /enabled = 0
Disabled
RS485 protocol
The message is send whatever is the control result, and it contains more information
than the Wiegand and the DataClock frames.
The message format (ASCII characters) includes the user identifier, but also the result
of the control, the date and time of the access request, and other data.
The sending of the message through the serial port, using RS484 protocol is
conditioned to two configuration keys.
Send access control result message using RS485 protocol on serial output port
app/send ID serial /enabled = 1
Enabled
app/send ID serial /enabled = 0
Disabled
app/send ID serial/mode = 485
RS485 protocol
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
98
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Ethernet port
Protocol selection
The protocol used to send the message through the Ethernet link, must be only one of
these protocols: UDP or TCP or SSL.
UDP protocol
Same comment as for RS485 protocol.
Send access control result message using UDP protocol on Ethernet port
app/send ID UDP/enabled = 1
Enabled
app/send ID UDP /enabled = 0
Disabled
TCP protocol
Same comment as for RS485 protocol.
Send access control result message using TCP protocol on Ethernet port
app/send ID ethernet /mode = 0
Disabled
app/send ID ethernet /mode = 1
UDP
app/send ID ethernet /mode = 2
TCP
SSL protocol
For details about SSL protocol, please refer to SSL Solution for MorphoAccess®
document.
Wi-Fi™ channel
Instead of Ethernet connection, the terminal can be connected using a wireless Wi-Fi™
b/g connection. Please refer to Wi-Fi™ Network configuration section for more
information.
The message format and the protocols supported are the same as the Ethernet channel:
UDP, or TCP or SSL.
Warning: it is not possible for a terminal to be connected through Ethernet and
through Wi-Fi™ at the same time.
99
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Note about terminal clock deviation
The message send through IP and RS485 includes the date/time of access control
result. The terminal clock has a +/- 4 sec per day typical time deviation at +25°C.
At 50°C, the time deviation may be up to -8 sec per day.
For features that requiring time precision (such as SSL protocol or DESFire™
contactless card), the clock of the MorphoAccess® terminal must be synchronized
regularly with an external clock (using the appropriated ILV command).
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
100
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
LED IN feature
Description
When this feature is activated, the terminal waits for an answer from a distant system,
before granting the access. If no answer is received the access is denied even of the
biometric check is positive.
This feature is to be use in addition to the Sending the access control result to a distant
system function.
Figure 39: LED IN feature
For more information about this interface, please refer to MorphoAccess® VP Series
Installation Guide.
Process
•
•
•
•
•
If the user is recognized, the terminal sends the user’s identifier to the central
access controller (within the access result message).
Then the terminal starts to wait, during an adjustable timeout, for the closure of a
switch between LED1 and GND, or between LED2 and GND.
During terminal wait period, the controller performs its own access rights checks
for the identified user.
Depending on the result of the result, the controller close the switch between
LED1 and GND wires to grant the access, or closes the switch between LED2 and
GND to deny the access. In case of time-out, the access is also denied.
The terminal notify the result of the global access control check to the user, and
return to “wait for access request” state, as soon as LED1 and LED2 wires are
reset to default state again.
Using LED1 signal only
If the controller provides only a “access granted” output, then the relay contact should
be connected between LED1 and GND wires.
The terminal uses the wait for LED1/LED2 signal timeout as “access denied” answer.
101
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Then to reduce the user wait time, the value of the wait time for GND1/GND2 signal
must be defined to value a little bit greater than maximum controller answer delay.
Using LED1 and LED2 signals
When the controller provides a relay contact for each possible answer, then:
• The “access denied" relay contact must be connected to LED1 and GND wires
• The “access granted” relay contact must be connected to LED2 and GND wires.
Activation key
This feature is activated by a dedicated configuration key.
LED IN feature activation
app/led IN/enabled = 0
Disabled (default)
app/led IN/enabled =1
Enabled
Configuration key
The value of the wait time for the answer of distant system (LED1 or LED2 signal) is
defined by a dedicated configuration key. In case of timeout, the access is denied.
LED IN acknowledgement timeout in 10 ms
app/led IN/controller ack timeout
SSE-0000082427-01
January 2011
300 (0 to 268435455)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
102
MorphoAccess® VP Series - User Guide
Section 11: Compatibility with an Access Control System
Time mask feature
Description
The MorphoAccess® terminal provides a feature that enables to deny the access to a
normally authorized user, on the base of time of access request.
One typical application is to allow the access during regular working hours, and to
deny the access to the same user during closed hours (night, week end).
This feature is compatible with MEMS and MorphoEnroll applications.
Please refer to MorphoAccess® Host Interface Specification document for mode
information.
Database
To use this feature the local database must be created with a specific additional user
data field.
Each user may have a different time mask from other users.
The time mask is defined by slots of 15 minutes over a week. For each of these 84
slots (of 15 minutes) the access must be specified either granted or denied.
Warning: if this field does not exist, activating this feature will forbid the access to all
users.
Activation key
The activation of this feature is done using one dedicated configuration key.
Enabling the Time mask feature
103
app/modes/time mask = 1
Enabled
app/modes/time mask = 0
Disabled
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Section 12 MorphoAccess® VP Series terminal
sound and light Interface
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
104
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Light and sound signals
Light signal description
Intermittent "Pulse": 1 second OFF and 0.5 second ON
Sample
Intermittent blue "Pulse"
Fast intermittent "Pulse": 0.5 second OFF and 0.5 second ON.
Sample
Fast Intermittent yellow "Pulse"
Slow intermittent "Pulse": 1 second OFF, 1 second ON
Sample
Slow intermittent red "Pulse"
Audible signal
The volume of the audible signal can be tuned by a specific configuration key
Level of the audible signal
105
app/GUI/volume = 0
Volume off
app/GUI/volume = 1 to 10
Volume tuning (from low to high)
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Signals table
Terminal status
Status
Biometric Status LED
Sensor
Buzzer
Waiting for a finger
OFF
OFF
OFF
Waiting for a badge
OFF
BLUE
OFF
Waiting for a finger or a card
OFF
BLUE
OFF
Bad finger placement
OFF
Intermittent
YELLOW pulse
OFF
Finger removed too quickly
OFF
YELLOW
OFF
Finger acquisition running
GREEN
OFF
OFF
No database or empty database
OFF
Intermittent
YELLOW pulse
OFF
USB mass storage key can be OFF
removed
Fast intermittent CYAN OFF
pulse
A distant operation is running
OFF
Intermittent
MAGENTA pulse
OFF
biometric OFF
Intermittent
MAGENTA pulse
OFF
OFF
Intermittent RED pulse
OFF
Event
Biometric
Sensor
Status LED
Buzzer
Control OK
OFF
GREEN
High-pitched
beep
Control NOK
OFF
RED
Low-pitched
beep
An
upgrade
of
component is running
Sensor KO
Access control result
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
106
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Terminal states
Identification or Authentication - Waiting for a finger on the sensor
The identification mode is activated, and the MorphoAccess® terminal is waiting for
the placement of a finger on the biometric sensor.
Biometric
Sensor
backlight
OFF
Status LED
Not significant
Buzzer
Off
Authentication - waiting for user's contactless card
One of the authentication modes is activated, and the MorphoAccess® terminal is
waiting for the presentation of a contactless card.
Biometric
Sensor
backlight
Not significant
Status LED
On, permanent blue
Buzzer
Off
Identification and Authentication - No database or empty database
The selected access control mode requires at least one record in the local database, and
there is no database or no record in the database.
107
Biometric
Sensor
backlight
OFF
Status LED
Slow intermittent yellow
"Pulse"
Buzzer
Off
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Multi-factor mode - waiting for user’s finger or user’s card
The identification mode, and one of the authentication modes are activated, and the
MorphoAccess® terminal is waiting for the placement of a finger on the biometric
sensor or for the presentation of a contactless card.
Biometric
Sensor
backlight
OFF
Status LED
On, permanent blue
Buzzer
OFF
Finger biometric data acquisition in progress
The MorphoAccess® VP Series terminal emits this signal when the acquisition of the
biometric data of the finger placed on the sensor, is in progress. Don’t remove the
finger when this signal is displayed.
Biometric
Sensor
backlight
ON (GREEN)
Status LED
OFF
Buzzer
OFF
Finger misplaced
The MorphoAccess® VP Series terminal emits this signal when the placement of the
finger is not optimized. Try to move horizontally the finger, to place it closer to the
middle of the sensor. If it doesn’t work, try to remove and then replace the finger on
the sensor.
Biometric
Sensor
backlight
ON (GREEN)
Status LED
Slow
intermittent
yellow "Pulse"
Buzzer
OFF
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
108
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Proxy mode - waiting for distant system command
When the proxy mode is enabled and when the terminal is expecting for a command
from the distant system, there is no local signal
Biometric
Sensor
backlight
OFF
Status LED
OFF
Buzzer
OFF
Biometric Sensor start up error
The terminal fails to start the biometric sensor. If the trouble persists after several
terminal start-ups, please contact customer service.
Biometric
Sensor
backlight
OFF
Status LED
Slow
intermittent
red "Pulse"
Buzzer
OFF
Terminal maintenance
A configuration operation is in progress (biometric database update, configuration key
value change, access request log file acquisition, etc…). Normal process will be
available again as soon as the configuration operation is completed. This signal is
displayed during remote management through TCP, and during USB mass storage key
processing.
109
Biometric
Sensor
backlight
OFF
Status LED
Slow
intermittent
magenta "Pulse"
Buzzer
OFF
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Maintenance: Biometric Sensor firmware update
This signal is emitted when the biometric Sensor firmware update is in progress. This
update occurs only at first start up of the terminal after a terminal firmware update.
Biometric
Sensor
backlight
OFF
Status LED
Slow
intermittent
magenta "Pulse"
Buzzer
OFF
Maintenance: USB mass storage key can be removed
This signal Is emitted when the USB Mass Storage key, used to configure the terminal,
can be removed from the USB port. The USB Mass Storage key must be removed to
complete the maintenance process.
Biometric
Sensor
backlight
OFF
Status LED
Fast
intermittent
cyan "Pulse"
Buzzer
two medium pitched
notes (only once)
Anti-tamper or anti-pulling alarm
This signal is emitted when the terminal has detected front cover withdraw, or a
separation from the wall support.
Biometric
Sensor
backlight
Not significant
Status LED
Slow red blinking
Buzzer
Low pitched notes
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
110
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Access request result
Identification or Authentication - Access granted
The user is recognized and the access is allowed.
Biometric
Sensor
backlight
Not significant
Status LED
Green 1s flash
Buzzer
1 second high –
pitched note
Identification or Authentication - Access denied
The user is not recognized, or the access is not allowed to this user (by Time Mask
feature or by the Central Access Controller).
Biometric
Sensor
backlight
Not significant
Status LED
Red 1s flash
Buzzer
second
pitched note
low
Authentication - Timeout while waiting for finger on the sensor
Authentication mode only: time-out occurs during the wait for a finger on the sensor
111
Biometric
Sensor
backlight
Not significant
Status LED
Red 1s flash
Buzzer
second
pitched note
low
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 12 MorphoAccess® VP Series terminal sound and light Interface
Finger removed too earlier
The terminal emits this signal if the finger is removed too earlier, while the finger
biometric data acquisition is in progress.
Biometric
Sensor
backlight
OFF
Status LED
Yellow 1s Flash
Buzzer
OFF
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
112
MorphoAccess® VP Series - User Guide
Section 13: Compatible Accessories, Software Licenses and Software Applications
Section 13: Compatible Accessories, Software
Licenses and Software Applications
113
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Section 13: Compatible Accessories, Software Licenses and Software Applications
Compatible accessories & software licenses
The following items can be ordered directly toMorpho or official distributor, so as to
enjoy all the features of your MorphoAccess® VP Series terminal:
• Power supply units
• Contactless smartcards: MIFARE™ 1K or 4K ; DESFire™ 2K, 4K or 8K
• MA WI-FI PACK, containing a Wi-Fi™ USB dongle and a Wi-Fi™ license to
activate Wi-Fi™ capability on your terminal
• MA 10K USERS License, enabling database upgrade from 3,000 users capacity
(*2 templates) to 10,000 users capacity (*2 templates)
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
114
MorphoAccess® VP Series - User Guide
Section 13: Compatible Accessories, Software Licenses and Software Applications
Compatible software applications
MorphoAccess® VP Series terminals are fully compatible with:
• MorphoAccess® Enrolment & Management System (MEMS) application
• Morpho Integrator’s Kit (MIK) software development kit
• MorphoEnroll enrolment application
115
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Appendix 1: Finger placement rules
Appendix 1: Finger placement rules
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
116
MorphoAccess® VP Series - User Guide
Appendix 1: Finger placement rules
Finger placement recommendations
117
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Appendix 1: Finger placement rules
To ensure a good acquisition quality, please leave the finger on the biometric sensor
until the backlight is turned off.
Finger condition
The following recommendations regarding finger condition will also help to get
optimal quality at acquisition:
• If wet, wipe finger
• If dry or cold, warm up finger
• If dirty, wash hands
• Remove bandages or adhesive tapes from finger
• Do not press or tense finger to avoid blood vessels constriction
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
118
MorphoAccess® VP Series - User Guide
Appendix 2: Bibliography
Appendix 2: Bibliography
119
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Appendix 2: Bibliography
MorphoAccess® terminal bibliography
How to get latest version of the documents
The last version of the documents below is available on a CD/ROM package from our
factory, or downloadable on our web site at the address below:
www.biometric-terminals.com
(Login and password required).
To get your login, please send us a mail to the address below:
hotline.biometrics@t.my-technicalsupport.com
Installation Information
MorphoAccess® VP Series Installation Guide, ref. SSE-0000083011
This document describes terminal physical mounting procedure, electrical interfaces
and connection procedures
Administrator Information
MorphoAccess® Parameters Guide, ref. SSE-0000062458
This document describes all configuration keys of MorphoAccess® terminal.
SSL Solution for MorphoAccess®, ref. SSE-0000069007
This document describes the SSL Solution deployment for MorphoAccess® terminal,
with MATM security plug-in.
MorphoAccess® Terminal License Management, ref. SSE-0000066855
This document details how to manage MorphoAccess® terminal licenses.
MorphoAccess® Enrolment station user guide, ref. SSE-0000035933
The chapter 15 “Configure MorphoAccess® network parameters” describes how to
configure the network parameters, for Ethernet and Wi-Fi™, of a MorphoAccess®
terminal, with MATM application.
Developer Information
MorphoAccess® Host System Interface Specifications, ref. SSE-0000056821
This document describes the commands supported by the MorphoAccess® terminal,
which can be sent by a Host System.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
120
MorphoAccess® VP Series - User Guide
Appendix 2: Bibliography
MorphoAccess® Remote Messages Specifications, ref. SSE-0000062580
Details how the MorphoAccess® terminal sends the access control result to a distant
system.
MorphoAccess® Contactless Card Specification, ref. SSE-0000062610
This document describes the format and the localization on contactless card, of the
data required by the authentication modes of the MorphoAccess® terminal.
Support Tools
MorphoAccess® Configuration Tool User Guide, ref. SSE-0000036539
This document describes the Configuration Tool application, which enables to
configure a MorphoAccess® terminal through a IP link (Ethernet or Wi-Fi™).
MorphoAccess® Terminal Management User Guide, ref. SSE-0000068869
This document describes the MATM application, which enables to configure a
MorphoAccess® terminal through Ethernet or Wi-Fi™.
MorphoAccess® USB Network Tool User Guide, ref. SSE-0000043164
This document describes how to specify the value of the network parameters of a
MorphoAccess® terminal, using a USB mass storage key.
MorphoAccess® USB encoder User Guide, ref. SSE-0000050386
This document describes how to configure a MorphoAccess® terminal, using a USB
mass storage key.
MorphoAccess® Firmware Upgrade Guide, ref. SSE-0000038184
This document describes the firmware upgrade process of a MorphoAccess® terminal.
121
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Appendix 3: Support
Appendix 3: Support
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
122
MorphoAccess® VP Series - User Guide
Appendix 3: Support
Troubleshooting
Terminal IP address is unknown or terminal is not reachable
Use USB Network Tool to set a valid network address in your terminal. Refer to USB
Network Tool User Guide.
Biometric Sensor backlight is off
Verify that the base contents at least one record. Check that identification mode is
enabled.
Terminal returns erratic answers to ping requests
Check the subnet mask. Ask your network administrator for the right value.
Check that each device connected to the network has a different IP address.
123
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
SSE-0000082427-01
January 2011
MorphoAccess® VP Series - User Guide
Appendix 3: Support
Customer service
Repair center
Morpho
SAV Terminaux Biométriques
Boulevard Lénine
BP428
76805 Saint Etienne du Rouvray
FRANCE
Phone: +33 2 35 64 53 52
Hotline and customer assistance
Morpho
Support Terminaux Biométriques
18, Chaussée Jules César
95520 OSNY
FRANCE
hotline.biometrics@t.my-technicalsupport.com
Phone: + 33 1 58 11 39 19
(9H00am to 6H00pm French Time, Monday to Friday)
http://www.biometric-terminals.com/
To access this service, please contact us in order to get your login.
Please send us an email rather than call by phone.
SSE-0000082427-01
January 2011
MORPHO DOCUMENT. REPRODUCTION AND DISCLOSURE PROHIBITED
124
Copyright ©2011 Morpho
Head office: Le Ponant de Paris
27, rue Leblanc - 75512 PARIS CEDEX 15 – France
www.morpho.com
Head office: Le Ponant de Paris
27, rue Leblanc - 75512 PARIS CEDEX 15 – France
www.morpho.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 126
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : f9349262-4d4f-11e0-0000-636a16ac4002
Producer                        : GPL Ghostscript  9.0
Keywords                        : ()
Modify Date                     : 2011:03:10 09:57:26+01:00
Create Date                     : 2011:03:10 09:57:26+01:00
Creator Tool                    : PDFCreator Version 1.2.0
Document ID                     : f9349262-4d4f-11e0-0000-636a16ac4002
Format                          : application/pdf
Title                           : DRAFT_MA_VP_User_Guide
Creator                         : gt218377
Description                     : ()
Author                          : gt218377
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZBW-MAVPDUAL

Navigation menu