SAGEMCOM BROANDS FAST3284U Cable Modem User Manual rev

SAGEMCOM SAS Cable Modem rev

User manual rev.pdf

Download: SAGEMCOM BROANDS FAST3284U Cable Modem User Manual rev
Mirror Download [FCC.gov]SAGEMCOM BROANDS FAST3284U Cable Modem User Manual rev
Document ID2459915
Application IDCWgn8icckZ2Vlw7Wvan6Cw==
Document DescriptionUser manual rev.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize64.68kB (808514 bits)
Date Submitted2014-12-01 00:00:00
Date Available2014-12-01 00:00:00
Creation Date2014-06-26 16:26:23
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2014-11-28 11:09:23
Document TitleMicrosoft Word - FAST3284_QuickUserGuide_V2_Tricom.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: G132252

F@ST 3284 u User Manual
1. Introduction
This F@ST 3284u Cable Gateway is an Embedded Media Terminal Adapter (EMTA) which is CableLabs DOCSIS 3.0 and
PacketCable 1.5 compliant. It provides high-speed Internet access as well as cost-effective, toll-quality telephone voice and
fax/modem services over residential, commercial, and education subscribers on public and private networks via an existing
CATV infrastructure. F@ST 3284u offers high-speed LAN connectivity with 4 Gigabit Ethernet ports and one integrated
Wireless LAN access point compatible with IEEE 802.11a/b/g/n. The Wireless access point is operating on 2.4GHz band.
Package Contents
F@S T3284u Gateway
x1
Ethernet Cable (RJ45)
x1
Phone Cable (RJ11)
x1
Quick Start Guide
x1
Power Supply Unit
x1
2. Hardware Connection
16
10
11
12
5 6
13
14 15
Page 1
LED Power ON/OFF
LED Downstream - indicate receiving RF DS traffic
LED Upstream - indicate receiving RF US traffic
LED Internet ON/OFF
LED WiFi ON/OFF
LED Telephone Line 1
LED Telephone Line 2
WPS button with Blue LED.
Wireless ON/OFF button
10
RJ-11 Telephone port lines 1 and 2
11
Ethernet 10/100/1000 BaseT RJ-45 connector
12
Restore To Factory Defaults button
13
RF coaxial F-connector
14
Power plug
15
Power switch ON/OFF
16
USB port
Wall Mounting
The number of the screw: 2 pcs
Direction for wall mounting: LED panel upward.
Dimension for the screw: 5~7.5 mm
There are 2 slots on the underside of the modem that can be used for wall mounting.
You will need 2 suitable screws which screw diameter would be 5~7.5 mm to wall mount the Cable Gateway.
Note: When wall mounting the unit, ensure that it is within reach of the power outlet.
To wall mount the unit:
1. Ensure that the wall you use is smooth, flat, dry and sturdy and use the 2 screw holes which are 120 mm apart from
each other.
2. Fix the screws into wall, leaving their heads 3 mm (0.12 inch) clear of the wall surface.
3. Remove any connections to the unit and locate it over the screw heads. When in line, gently push the unit on to the
wall and move it downwards to secure.
Page 2
3. Connecting the F@ST3284 Gateway to Your Computer
Installation Procedure for Ethernet Interface
Follow the steps below for proper installation:
1.
Make sure your computer meets the system requirements.
2.
Connect a coaxial cable to the wall plug
3.
Connect a coaxial cable to the CABLE connector on the F@ST3284u and screw it at the bottom manually (do not force).
Note: To speed up the registration process of F@ST3284u, the coaxial cable should be connected to the gateway prior to the power connector.
4.
Connect the RJ45 Ethernet cable to the ETHERNET connector on the gateway, connect the other end with the
10/100/1000BaseT Ethernet port on your computer.
5.
Plug the RJ11 telephone cord(s) to the TEL 1 or TEL2 connector (s) of the cable modem. (Plug the RJ11 telephone cord(s) to
the PSTN connector on the modem, connect to the PSTN service provider. This step is for EMTA with PSTN model only.)
6.
Plug the power supply unit into the POWER connector of the modem.
7.
Plug the other end of the power supply unit into a power outlet.
8. Power ON the F@ST3284u by pressing the ON/O FF button on the rear panel of the F@ST3284u.
9.
The cable gateway will look for the proper cable modem signal in the Cable Television network and process the initial
registration. The cable gateway is ready for data transfer after the LED “INTERNET” is in solid white. The gateway is ready to
make a phone call after the LED “Tel1” or “Tel2” is in solid white.
Note: The RESET button at the rear panel is for maintenance purpose only.
Cable
splitter
The screen of the coaxial cable is intended to be connected to earth in the building installation
Page 3
4. Wireless Connection
Step 1
Step 3
• Under the gateway, on the
label, note the reference of
SSID and WPA wireless
password.
Step 2
o In this new Window, search
for the SSID value and select
it by double clicking on it.
Step 4
o The computer asks for a
password. It is the WPA
wireless password.
• Click on “Start” then on:
Network Connection
Wireless network
connection
o Once the password entered
twice, press “Connection”
button. WiFi Configuration is
finished.
5. F@ST3284u Personalization
Step 1
•
Step 2
Open an Internet session and type the following address:
• Connect by typing:
http://192.168.1.1
Username: admin
Password: admin
• Click on “OK” button
Step 3
Status
To know the state of your connection of your F@ST3284u
Basic
To perform the basic configuration of your F@ST3284u
Advanced
To perform advanced routing configuration of your F@ST3284u
Firewall
To protect your LAN equipment from malicious attacks
Parental Control
To safely restrict and control the Internet usage to your family
Wireless
To configure the WiFi network of your F@ST3284u
MTA
To check the telephony status of your F@ST3284u
Page 4
6. Precautions and Warnings
Before connecting and disconnecting cables, stop using the F@ST3284u, and then disconnect it from h
t e power supply. Ensure that your
hands are dry during operation.
Keep the F@ST3284u far from sources of heatand fire, such as a heater or a candle.
Do not block the openings on the F@ST3284u with any object.Reserve a minimum space of 10 cm around the F@ST3284u for heat
dissipation.
Place the F@ST3284u on a stable surface in a cool and well-ventilated indoor area. Donot expose the F@ST3284u to direct sunlight
. Use
the F@ST3284u in an area with a temperature ranging from 0
° C to 40°C.
Keep the F@ST3284u far from electronic appliances that generate strong magnetic or electric fields, such as a microwave oven or a
refrigerator.
Do not place any object (such as a candle or a water container) on the F@ST3284u. If any foreign object or liquid enters the device, stop
using the device immediately, power it off, remove all the cables connected to it, and then contact an authorized service center.
During thunderstorms, power off the F@ST3284u, and then remove all he
t cables connected to it to prevent it from getting damaged due
to lightning strikes.
Do not use the F@ST3284u or Power Supply Unit (PSU) after a fall or strong impact.
Do not use in high dust, or with dampness exceeding 80%.
Do not open or service the F@ST3284u or PSU. In any event of failure, contact the support center.
Disconnect the PSU before cleaning.
This F@ST3284u produces radio frequency energy in the 2.4 GHz spectrum. It must be positioned to minimum distance of
20 cm from any nearby person.
The F@ST3284u must operate at an altitude between 0 and 2000m.
Electrical warnings
The connection of the product to electrical sector is of type A.
The power supply is designed to be connected to a network feed TT or TN
It can not be connected to an electrical installation type scheme IT (supply independent neutral).
The F@ST3284u must exclusively be used with the Power Supply Unit (PSU) delivered within the same package.
The PSU must be plugged to an electrical network delivering a 110V nominal voltage in 60Hz.
Protection against short circuits and leakage between phases, neutral and earth must be assured by the building's electrical installation.
The power circuit of this equipment must be fitted with a 16A protection against overcurrent and differential protection.
Insure the cable and AC input are not damaged. Do not cut, break, or bend the DC cable
The TEL1 and TEL2 inputs allow you to connect a phone device. The wire connections between the inputs TEL1/TEL2 and the phone
must not leave the building.
7. Others
This symbol on the device (and any included batteries) indicates that the device (and any included batteries) should
not be disposed of as normal household garbage. Do not dispose of your device or batteries as unsorted municipal
waste. The device (and any batteries) should be handed over to a certified collection point for recycling or proper
disposal at the end of its life.
For more detailed information about the recycling of the device or batteries, contact your local city office, the household
waste disposal service, or the retail store where you purchased this device.
The disposal of this device is subject to the Waste from Electrical and Electronic Equipment (WEEE) Directive of the
European Union. The purpose for separating WEEE and batteries from other waste is to minimize any environmental impact
and health hazard due to the presence of hazardous substances.
The EC marking certifies that the product complies with the essential requirements of the R&TTE directive of the
European Parliament and Council on radio equipment and telecommunication terminal equipment, and the mutual
acknowledgement of their compliance, together with the essential requirements of directive ErP 2009/125/CE on
ecodesign requirements. This marking certifies that the equipment is compliant in respect of the health and safety of users,
the electromagnetic compatibility of the equipment and the correct use of the radio frequency spectrum and reduction of the
impacts of the product on the environment.
Page 5
Safety and Certifications
Important Information about the Sagemcom F@ST3284u:
Installation and Safe Usage Instructions:
1. Place the router in a horizontal orientation on a flat surface.
2. Connect the manufacturer supplied AC to DC power adapter. The F@ST3284u requires the use of a
12 VDC, 2000 mA power adapter. Only use a manufacturer supplied and approved power adapter and
Ethernet cable.
3. Connect the F@ST3284u to the AC Mains in accordance with the installation instructions in this
booklet, and the markings on the identification label (voltage, current, and frequency of electricity
network).
4. Connect the Ethernet cable (provided) to one of the RJ45 ports on the product labeled "1", "2", "3", or
"4". Then connect the other end of the Ethernet Cable to the Ethernet port of a computer. Repeat as
necessary for the other available Ethernet ports.
When using this device, basic safety precautions should always be followed to reduce the risk of
fire, electric shock, and injury to persons including the following:
1. Do not use this product near water and avoid contact with moisture. For example, do not use near a
bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. Care
should be taken so that liquids are not spilled on this equipment.
2. This equipment is for indoor use only, do not place or install in an outdoor location.
3. Place your product on a firm, solid surface, no obstacle at a minimum distance of 20cm (0.65ft). If you
put it on something unsteady, it may fall and be damaged. If you place it on a soft surface, such as
rug, sofa or cushion, the vents may be blocked, causing the product to overheat.
4. Never insert objects into the vents of this equipment as this can result in the risk of electrical shock or
fire.
5. As the power adapter is the only way to connect to the electrical network, the product must be
installed near an easily accessed power outlet.
6. This equipment should only be operated from the type of power supply (Voltage and Current)
indicated on the marking label.
7. Do not overload wall outlets or extension cords. Doing so can result in the risk of fire or electrical
shock.
8. Avoid blocking any vent openings or exhaust exits on this equipment. Do not place equipment in a
built-in installation such as a cabinet that may impede the flow of air through the ventilation openings.
9. The equipment should be situated away from heat sources such as radiators, heat registers, stoves,
or other heat producing appliances and equipment.
10. Care should be taken to ensure that the power cord is routed, so it is not likely to be walked on or
pinched by items placed upon or next to it.
11. Unplug this equipment before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp
cloth for cleaning only.
12. This equipment is not user serviceable and is to be serviced by qualified personnel only. Do not
disassemble this equipment. If service is required, disconnect all power from the equipment and
consult qualified service personnel.
13. To disconnect this equipment from AC power, unplug the power supply from the AC wall socket.
14. Connect only to in house equipment (SELV interface). It is not allowed to connect to public cable
distribution or cable television network.
15. Use the product in the environment specified as below:
Air temperature between 0°C and +40°C.
Relative humidity between 20% and 90%.
Altitude: 5000 meters (16404ft) maximum.
North American Cable Installer: This reminder is provided to call your attention to Article 820.93 of
the National Electrical Code (Section 54 of the Canadian Electrical Code, Part 1) which provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to
the grounding system of the building as close to the point of cable entry as practical.
Save these Instructions!
25xxxxxxx-A
17 July 2014
Safety and Certifications
Federal Communications Commission (FCC) Statements
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Label
Modifications:
You are cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.
FCC Responsible Party:
Sagemcom USA
14651 N. Dallas Parkway
Suite 900
Dallas, TX 75254
Phone: 972-674-4100
Radio Frequency Interference Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
25xxxxxxx-A
17 July 2014
Safety and Certifications
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device produces radio frequency energy in the 2.4GHz spectrum. The antenna must be positioned
to keep a minimum distance of 20cm (0.65ft) from the radiating element to any nearby person.
Issued by Sagemcom Broadband SAS
Sagemcom
250, route de l'Empereur - 92500 RUEIL MALMAISON
FRANCE
© Sagemcom Broadband SAS 2012
All rights reserved. Subject to availability.
Rights of modifications reserved.
www.sagemcom.com
25xxxxxxx-A
17 July 2014
Safety and Certifications
Wall Mounting (Optional)
While many users place their F@ST3284u product on their desk, it can be optionally wall mounted.
The number of the screw: 2 pcs.
Direction for wall mounting: LED panel upward.
Dimension for the screw: 5~7.5 mm.
There are 2 slots on the underside of the modem that can be used for wall mounting.
You will need 2 suitable screws which screw diameter would be 5~7.5 mm to wall mount the
F@ST3284u.
Note: When wall mounting the unit, ensure that it is within reach of the power outlet.
To wall mount the unit:
1. Ensure that the wall you use is smooth, flat, dry and sturdy and use the 2 screw holes which are
120mm (4.72 inch) apart from each other.
2. Fix the screws into wall, leaving their heads 3 mm (0.12 inch) clear of the wall surface.
3. Remove any connections to the unit and locate it over the screw heads. When in line, gently push the
unit on to the wall and move it downwards to secure.
25xxxxxxx-A
17 July 2014
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
Note: The country code selection is for non-US model only and is not
available to all US model. Per FCC regulation, all WiFi product marketed in
US must fixed to US operation channels only.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 5.0 (Windows)
Create Date                     : 2014:06:26 16:26:23+02:00
Modify Date                     : 2014:11:28 11:09:23+08:00
Metadata Date                   : 2014:11:28 11:09:23+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : G132252
Title                           : Microsoft Word - FAST3284_QuickUserGuide_V2_Tricom.doc
Document ID                     : uuid:ab73f6ff-b472-4fd6-a7f2-713978b5e654
Instance ID                     : uuid:c4d51daa-7929-4920-a8af-aee34d25f022
Has XFA                         : No
Page Count                      : 11
Author                          : G132252
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VW3FAST3284U

Navigation menu