SAGEMCOM BROANDS HILONC GSM/GPRS Module User Manual HiloNC
SAGEMCOM SAS GSM/GPRS Module HiloNC
Contents
- 1. User Manual
- 2. Users Manual
Users Manual
page 1/36 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY NOTE D'ETUDE / TECHNICAL DOCUMENT REFERENCE ETUDE / PROJECT URD1 – OTL 5665.1– 002 / NOM DE L’ETUDE Code 70 884 TA1 HiloNC Module TITRE / TITLE : HiloNC Application note Edition Approbations /Approvals Chef Unité Project design manager Responsable d’entité / Product design manager T. Fu M. Boutboul E. Sillère N° Rédacteur(s) Chef de projet Author(s) J.DUMONT 03 Nom Name Date R&D unit manager Assurance Qualité / R&D quality assurance 27/06/08 Signature RESUME / SUMMARY This document is HiloNC module application note. Mots clés / Keywords : Cellular, module, GSM, GPRS, application, M2M √ DIFFUSION INTERNE / INTERNAL DISTRIBUTION REDACTEUR(S) / AUTHOR (S) + F.FREULON, F.GOUERE . Distribution externe pour les prestataires de services : renseigner dans la rubrique ci-dessous sous la forme « SOCIETE (P. Nom) » DIFFUSION EXTERNE sous convention de confidentialité : EXTERNAL DISTRIBUTION with confidentiality agreement : …………. Enregistrement relatif à la qualité (ERQ) / Quality record A déposer en enveloppe soleau / Put in a soleau envelope Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 2/36 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY NOTE D'ETUDE / TECHNICAL DOCUMENT FICHE RECAPITULATIVE / SUMMARY SHEET Ed Date Date 27/06/2008 07/10/2008 10/11/2008 Référence Reference URD1– OTL 5665.1– 002 / 70 884 URD1– OTL 5665.1– 002 / 70 884 URD1– OTL 5665.1– 002 / 70 884 Rédacteur(s) Relecteur(s) Author(s) Steven Long Bingming Chen AMMARI. M. Reviser(s) Tiejun Fu / M. Boutboul DUMONT J. AMMARI M. Dumont J. Pages modifiées / Changed pages Observations Comments Création du document / Document creation UART Update §3.6 and §3.10; P25 §3.1, §3.9, §3.12 Clarification on Vbackup connection. Reset duration 10ms. Sim card connection figure 3. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 3/36 HiloNC Application Note Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 4/36 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY SOMMAIRE / CONTENTS Direction des Recherches et des Développements Etablissement de VELIZY ........................................................... 1 NOTE D'ETUDE / TECHNICAL DOCUMENT .......................................................................................................... 1 Direction des Recherches et des Développements Etablissement de VELIZY ........................................................... 2 NOTE D'ETUDE / TECHNICAL DOCUMENT .......................................................................................................... 2 FICHE RECAPITULATIVE / SUMMARY SHEET .................................................................................................... 2 SOMMAIRE / CONTENTS.......................................................................................................................................... 4 FIGURES LIST ............................................................................................................................................................ 6 1. OVERVIEW ........................................................................................................................................................... 7 1.1 OBJECT OF THE DOCUMENT .................................................................................................................. 7 1.1 REFERENCE DOCUMENTS....................................................................................................................... 7 1.2 MODIFICATION OF THIS DOCUMENT .................................................................................................... 7 1.3 CONVENTIONS............................................................................................................................................ 7 2. BLOCK DIAGRAM................................................................................................................................................ 8 3. FUNCTIONAL INTEGRATION ............................................................................................................................ 9 3.1 HOW TO CONNECT TO A SIM CARD.................................................................................................... 10 3.2 HOW TO CONNECT THE AUDIOS? ....................................................................................................... 11 3.2.1 Connecting microphone and speaker ................................................................................................ 11 3.2.2 Recommended characteristics for the microphone and speaker .................................................... 12 3.3 PWM ............................................................................................................................................................ 13 3.3.1 PWM outputs........................................................................................................................................... 13 3.3.2 PWM for Buzzer connection .................................................................................................................. 14 3.4 POWER SUPPLY....................................................................................................................................... 14 3.5 EXAMPLE OF POWER SUPPLY ............................................................................................................. 15 3.5.1 Example 1............................................................................................................................................ 15 3.5.2 Example 2............................................................................................................................................ 15 3.5.3 Example 3............................................................................................................................................ 16 3.6 V24............................................................................................................................................................... 16 3.6.1 Complete V24 – connection HiloNC - host........................................................................................ 16 3.6.2 Complete V24 interface with PC........................................................................................................ 17 3.6.3 Partial V24 (RX-TX-RTS-CTS) – connection HiloNC - host ............................................................ 18 3.6.4 Partial V24 (RX-TX) – connection HiloNC - host .............................................................................. 19 3.6.5 Design impact on DTR usage ............................................................................................................ 19 3.7 SPI ............................................................................................................................................................... 19 3.8 GPIO ............................................................................................................................................................ 20 3.9 BACKUP BATTERY ................................................................................................................................... 20 3.9.1 Backup battery function feature ......................................................................................................... 20 3.9.2 Current consumption on the backup battery ..................................................................................... 20 3.9.3 Charge by internal HiloNC charging function.................................................................................... 20 3.9.4 Backup Battery technology recommended ....................................................................................... 21 3.10 HARDWARE POWER MANAGEMENT AND MULTIPLEXING INTERFACES.................................... 22 3.11 STARTING THE MODULE ........................................................................................................................ 22 3.12 MODULE RESET........................................................................................................................................ 22 3.13 MODULE SWITCH OFF ............................................................................................................................ 22 3.14 SLEEP MODE MANAGEMENT ................................................................................................................ 23 4. MANDATORY POINTS FOR THE FINAL TESTS AND TUNING..................................................................... 24 5. ESD & EMC RECOMMENDATIONS ................................................................................................................. 24 5.1 HILONC ALONE ......................................................................................................................................... 24 5.2 CUSTOMER’S PRODUCT WITH HILONC .............................................................................................. 24 5.2.1 Analysis................................................................................................................................................ 24 5.2.2 Recommendations to avoid ESD issues ........................................................................................... 24 6. RADIO INTEGRATION....................................................................................................................................... 25 6.1 ANTENNA ................................................................................................................................................... 25 Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 5/36 6.2 GROUND LINK AREA................................................................................................................................ 25 6.3 LAYOUT ...................................................................................................................................................... 25 6.4 MECHANICAL SURROUNDING ............................................................................................................... 26 6.5 OTHER RECOMMENDATIONS – TESTS FOR PRODUCTION/DESIGN ........................................... 26 7. AUDIO INTEGRATION ...................................................................................................................................... 26 7.1 MECHANICAL INTEGRATION AND ACOUSTICS ................................................................................. 26 7.2 ELECTRONICS AND LAYOUT ................................................................................................................. 27 8. RECOMMENDATIONS ON LAYOUT OF CUSTOMER’S BOARD ................................................................... 28 8.1 GENERAL RECOMMENDATIONS ON LAYOUT.................................................................................... 28 8.1.1 Ground ................................................................................................................................................. 28 8.1.2 Power supplies..................................................................................................................................... 28 8.1.3 Clocks................................................................................................................................................... 28 8.1.4 Data bus and other signals ................................................................................................................. 28 8.1.5 Radio .................................................................................................................................................... 28 8.1.6 Audio (see also § 10.2) ....................................................................................................................... 28 8.2 EXAMPLE OF LAYOUT FOR CUSTOMER’S BOARD........................................................................... 29 9. RECOMMANDATIONS FOR CUSTOMER INDUSTRIALIZATION.................................................................. 29 9.1 MOISTURE LEVEL..................................................................................................................................... 30 9.2 PACKAGE ................................................................................................................................................... 30 9.3 SOLDER MASK .......................................................................................................................................... 32 9.4 SOLDER PASTE ........................................................................................................................................ 32 9.5 PROFILE FOR REFLOW SOLDERING ................................................................................................... 32 9.6 SMT MACHINE........................................................................................................................................... 34 9.7 UNDERFILL................................................................................................................................................. 34 9.8 SECOND REFLOW SOLDERING ............................................................................................................ 35 9.9 HAND SOLDERING ................................................................................................................................... 35 9.10 REWORK .................................................................................................................................................... 35 10. LABEL ............................................................................................................................................................. 35 Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 6/36 FIGURES LIST Figure 1: Block diagram of HiloNC module...................................................................................................................... 8 Figure 2: SIM Card signals............................................................................................................................................. 10 Figure 3: Protections: EMC and ESD components close to the SIM ................................................................................ 10 Figure 4: Audio connection............................................................................................................................................. 11 Figure 5 : Filter and ESD protection of microphone........................................................................................................ 12 Figure 6: Filter and ESD protection of 32 ohms speaker ................................................................................................. 12 Figure 7: Buzzer connection ........................................................................................................................................... 14 Figure 8: GSM/GPRS Burst ............................................................................................................................................ 14 Figure 9: Example of power supply based on a DC/DC step down converter ................................................................... 15 Figure 10: Example of power supply based on regulator.................................................................................................. 15 Figure 11: Example with Linear LT1913 ........................................................................................................................ 16 Figure 12: Complete V24 connection between HiloNC and host...................................................................................... 17 Figure 13: connection to a data cable .............................................................................................................................. 18 Figure 14: Partial V24 connection (4 wires) between HiloNC and host ........................................................................... 18 Figure 15: Partial V24 connection (2 wires) between HiloNC and host ........................................................................... 19 Figure 16: Backup battery internally charged.................................................................................................................. 21 Figure 17: Charging curve of backup battery................................................................................................................... 21 Figure 18: Hardware interface between HiloNC and host ................................................................................................ 22 Figure 19: Antenna connection ....................................................................................................................................... 25 Figure 20: Forbidden area for via.................................................................................................................................... 26 Figure 21: Layout of audio differential signals on a layer n ............................................................................................. 29 Figure 22: Adjacent layers of audio differential signals ................................................................................................... 29 Figure 23: layer allocation for a 6 layers circuit .............................................................................................................. 29 Figure 24 : Solder mask design ....................................................................................................................................... 32 Figure 25 : Typical thermal profile ................................................................................................................................. 33 Figure 26 : CMS fiducials positions ................................................................................................................................ 34 Figure 27 : Underfill holes.............................................................................................................................................. 35 Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 7/36 1. OVERVIEW 1.1 OBJECT OF THE DOCUMENT The aim of this document is to describe some examples of hardware solutions for developing some products around the Sagem Communications HiloNC GPRS Module. Most part of these solutions is not mandatory. Use them as suggestions of what should be done to have a working product and what should be avoided thanks to our experiences. This document suggests how to integrate the HiloNC GPRS module in machine devices such as automotive, AMM (Automatic Metering Management), tracking system: connection with external devices, layout advises, external components (decoupling capacitors…). 1.1 REFERENCE DOCUMENTS URD1 OTL 5665.1 001 70883 - HiloNC technical specification URD1 OTL 5635.1 008 70248 - AT Command Set for SAGEM Hilo Modules 1.2 MODIFICATION OF THIS DOCUMENT The information presented in this document is supposed to be accurate and reliable. Sagem Communications assumes no responsibility for its use, nor any infringement of patents or other rights of third parties which may result from its use. This document is subject to change without notice. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 1.3 CONVENTIONS SIGNAL NAME : All signal name available on the pads of the HiloNC module is written in italic. F Specific attention must be granted to the information given here. 1.4 DECLARATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received; including interference that may cause undesired operation. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 8/36 2. BLOCK DIAGRAM Dual Saw Filter (850 /900 ) Band 1 (850 MHz ) 3 +2 Pads Antenna pad (900 MHz ) 3 Pads Band 2 VBAT T VGPIO VGPIO 1 Pad AUX _ADC 0 RXD / RTS / CTS / TXD / DCD / DTR / DSR / RI HSET _OUT _P Out HSET _OUT _N Audio Subsystem In 3 Pads JTAG RTC INTMIC _BIAS INTMIC _P Band 2 RFOL RFOH DCXO UART 8 Pads PWM [0:2] 850 / 900 /1800 /1900 Ramp _ DAC PWM 3 Pads SIM _DATA / SIM _CLK / SIM _RST / VSIM SIM 4 Pads PA + Switch (1900 MHz ) FE _CTRL PERIPHERALS GPIO [1:5] GPIO 5 Pads (18 00MHz ) RFIH SPI 5 Pads SPI _ CLK / SPI _ IRQ / SPI _OUT / SPI _IN / SPI _SEL ( 1800 /1900 ) RFIL EMC Subsystem 1 Pad POWER ADC CONTROL 1 Pad POK _IN Dual Saw Filter Band 1 RF Subsystem 1 Pad Power Supply System VBACKUP VBACKUP RESET RESET 1 Pad GROUND 26 MHz ADDR [22 :1] DATA [15 :0] External Memory NCS _RAM NCS _Flash NUB NLB NOE NWE 32 .768 KHz TMS / RTCK / TCK / NTRST / TDI / TDO / TEST / TEST1 / TEST2 Figure 1: Block diagram of HiloNC module Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited 9 Pads page 9/36 3. FUNCTIONAL INTEGRATION The improvement of Silicon technologies heads toward functionality improvement, less power consumption. The HiloNC module meets all these requirement and use last high end technology. I/Os among the 51 pads are in 2.8V domain which is suitable for most systems except : F All digital VSIM (the SIM I/Os at 1.8V or 2.9V) VBAT (from 3.2V to 4.5V). Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 10/36 3.1 HOW TO CONNECT TO A SIM CARD Figure 2: SIM Card signals HiloNC module provides the SIM signals on the 51 pads. A SIM card holder with 6 pads needs to be adopted to use the SIM function. Decoupling capacitors have to be added on SIM_CLK, SIM_RST, VSIM and SIM_DATA signals as close as possible to the SIM card connector to avoid EMC issues. Use ESD protection components to protect SIM card and module I/Os against Electro Static Discharges. The following schematic show how to protect the SIM access for 6 pads connector. Figure 3: Protections: EMC and ESD components close to the SIM Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 11/36 3.2 HOW TO CONNECT THE AUDIOS? The HiloNC module features one input audio path and one output audio path. The input path is single-end while the output path is differential. In this following chapter examples of design will be given including protections against EMC and ESD and some notes about the routing rules to follow to avoid the TDMA noise usually present in this sensitive area of design. Please note that acoustic competences are mandatory to get accurate audio performance on customer’s product. 3.2.1 Connecting microphone and speaker The HiloNC module can manage an external microphone (INTMIC_P) in single-end mode and an external speaker (HSET_OUT_P / HSET_OUT_N) in differential mode. Thus, one speaker and one microphone can be connected to the module. The bias supply to microphone is implemented in the module. F The speaker connected to the module should be 32 ohms. HSET_OUT_P HiloNC HSET_OUT_N Filter and ESD protection 32ohms speaker INTMIC_P MIC Figure 4: Audio connection If the design is ESD or EMC sensitive we strongly recommend to read the notes below. The weakness can either come from the PCB routing and placement or from the chosen components (or both). 3.2.1.1 Notes for microphone F Pay attention to the microphone device, it must not be sensitive to RF disturbances. Some microphones include two spatial microphones inside the same shell and allow to make an electrical F difference between the environment noise (received by one of the two mic.) and the active signal (received by the other mic. + noise) resulting in a very high SNR. If you need to have deported microphone out of the board with long wires, you should pay attention to the EMC and ESD effect. It is also the case when your design is ESD sensitive. In those cases, add the following protections to improve your design. To ensure proper operation of such sensitive signals, they have to be isolated from the others by analogue ground on customer’s board layout. (Refer to Layout design chapter) Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 12/36 Ferrite Bead INTMIC_P HiloNC MIC 18pF ESD protection Figure 5 : Filter and ESD protection of microphone 3.2.1.2 Notes for speaker As explained for the microphone, if the speaker is deported out of the board or is sensitive to ESD, use the schematic here after to improve the audio. 18pF ESD protection Ferrite Bead HiloNC HSET_OUT_P speaker HSET_OUT_N Ferrite Bead 18pF ESD protection Figure 6: Filter and ESD protection of 32 ohms speaker F HSET_OUT_P, HSET_OUT_N tracks must be larger than other tracks: 0.1 mm. described in the layout chapter, differential signals have to be routed in parallel (HSET_OUT_P and F AsHSET_OUT_N signals) F The impedance of audio chain (filter + speaker) must be lower than 32 Ohm. 3.2.2 Recommended characteristics for the microphone and speaker Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 13/36 3.2.2.1 Recommended characteristics for the microphone Item to be inspected Sensitivity Acceptance criterion - 40 dB SPL +/-3 dB (0 dB = 1 V/Pa @ 1kHz) Frequency response Limits (relatives values) Freq. (Hz) Lower limit 100 -1 200 -1 300 -1 1000 2000 -1 3000 -1.5 3400 -2 4000 -2 Current consumption Operating voltage S / N ratio Directivity Maximum input sound pressure level Radio frequency protection Upper limit 1.5 1 mA (maximum) DC 1 to 3 V (minimum) 55 dB minimum (A-Curve at 1 kHz, 1 Pa) Omni-directional 100 dB SPL (1 kHz) Maximum distortion 1% Over 800 -1200 MHz and 1700 -2000 MHz, S/N ratio 50 dB minimum (signal 1 kHz, 1 Pa) 3.2.2.2 Recommended characteristics for the speaker Item to be inspected Acceptance criterion Input power: rated / max 0.1W (Rate) Audio chain impedance 32 ohm +/- 10% at 1V 1KHz Frequency Range 300 Hz ~ 4.0 KHz Sensitivity (S.P.L) >105 dB at 1KHz with IEC318 coupler, Distortion 5% max at 1K Hz, nominal input power 3.3 PWM 3.3.1 PWM outputs The HiloNC module can manage two PWM outputs. They can be configured with appropriate AT command (for more details refer to AT command set for Sagem HiloNC module specification). User application can set for each output: Frequency between : 25.6KHz and 1083.3KHz Duty range from: 0 to 100% Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 14/36 note available PWM frequencies are too high to be used to make LEDs blinking. If purpose is to F Please make LEDs blinking (for network states indication for example), GPIO usage is more accurate. 3.3.2 PWM for Buzzer connection The HiloNC module can manage a dedicate PWM output to drive a buzzer. The buzzer can be used to alarm for abnormal state. Resistors should be added to protect the buzzer. The value of these resistors depends on the buzzer and the transistor. Normally, they can be set as 1K ohm. VBAT HiloNC R1 R2 PWM2 Figure 7: Buzzer connection 3.4 POWER SUPPLY The HiloNC module can be supplied by a battery or any DC/DC converter compliant with the module supply range 3.2V to 4.5V 2.2 A. The PCB tracks must be well dimensioned to support 2.2 A maximum current. The voltage ripple caused by resistance of power supply path (Battery internal resistance, tracks and contact resistance) could result in the low voltage to the module. F The HiloNC module does not manage the battery charging. 3.4.1.1 Burst conditions - Communication mode (worst case: 2 continuous GSM time-slot pulse): 1.8 GPRS Class10 577us 1.15ms Figure 8: GSM/GPRS Burst F A 47µF capacitor is highly recommended for VBAT and close to the module. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited 4.615ms page 15/36 3.5 EXAMPLE OF POWER SUPPLY 3.5.1 Example 1 It the following application note from Linear Technology LTC3440, this schematic is an example of a DC/DC power supply able to power 3.6V under 2.1A. This can be use with a AC/DC 5V unit or an USB or PCMCIA bus as input power source. Figure 9: Example of power supply based on a DC/DC step down converter 3.5.2 Example 2 If the whole power consumption is not an issue, this example of a voltage regulator used with an AC/DC 5V converter, can be used as a DC power supply. The voltage output is given by: VOUT = 1.235V × [1 + (R1 / R2)] To have 3.7V out R1=560K & R2=271.8K (270K+1.8K) Figure 10: Example of power supply based on regulator Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 16/36 3.5.3 Example 3 Simple boost converter with Linear LT1913 (see LT1316 evaluation kit document). Figure 11: Example with Linear LT1913 3.6 V24 The HiloNC module features a V24 interface to communicate with the Host through AT commands or for easy firmware upgrading purpose. It is recommended to manage an external access to the V24 interface, in order to allow easy software upgrade (baud rate up to 460.8kbps, validated with ATEN USB/Serial converter). F Pull-up resistors must be connected to DCD, DSR and RI signals if these signals are used. 3.6.1 Complete V24 – connection HiloNC - host A V24 interface is provided on the 51 pads of the HiloNC module with the following signals: RTS/CTS, RXD/TXD, DSR, DTR, DCD, RI. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 17/36 HiLoNC Module 39 40 33 34 35 36 38 37 DTE Device RXD CTS DSR DCD RI DTR TXD RTS TXD CTS DSR DCD RI DTR RXD RTS 2.8V signals 2.8V signals Note: GND is not represented DCE point of view DTE point of view Figure 12: Complete V24 connection between HiloNC and host 3.6.2 Complete V24 interface with PC It supports speeds up to 115.2 Kbps and may be used in auto bauding mode. To use the V24 interface, some adaptation components are necessary to convert the +2.8V signals from the HiloNC to +/- 5V signals compatible with a PC. HiLoNC Module 39 40 33 34 35 36 38 37 RS232 Transceiver IN IN IN IN IN OUT OUT OUT TXD CTS DSR DCD RI DTR RXD RTS OUT OUT OUT OUT OUT IN IN IN RXD CTS DSR DCD RI DTR TXD RTS 3.1V to +/-5.5V signals 2.8V signals DCE point of view SUBD9 Female Note: pin 5 is GND DTE point of view Figure 13: connection to a data cable To create your own data cable (for software download purpose…etc…) please refer to the following schematic as an example: Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 18/36 Figure 14: Example of a connection to a data cable 3.6.3 Partial V24 (RX-TX-RTS-CTS) – connection HiloNC - host When using only RX/TX/RTS/CTS instead of the complete V24 link, we recommend following schematic. HiLoNC Module 39 40 33 34 35 36 38 37 DTE Device RXD CTS DSR DCD RI DTR TXD RTS TXD CTS DSR DCD RI DTR RXD RTS 2.8V signals Note: GND is not represented 2.8V signals Figure 15: Partial V24 connection (4 wires) between HiloNC and host As we need DTR active (low electrical level), a loop DSR on DTR is sufficient because DSR is active (low electrical level) once the HiloNC is switched on. F DCD and RI can stay not connected and floating. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 19/36 3.6.4 Partial V24 (RX-TX) – connection HiloNC - host When using only RX/TX instead of the complete V24 link, we recommend following schematic. HiLoNC Module 39 40 33 34 35 36 38 37 DTE Device RXD CTS DSR DCD RI DTR TXD RTS TXD CTS DSR DCD RI DTR RXD RTS 2.8V signals 2.8V signals Note: GND is not represented DCE point of view DTE point of view Figure 16: Partial V24 connection (2 wires) between HiloNC and host We need DTR active (low electrical level), a loop DSR on DTR is sufficient because DSR is active (low electrical level) once the HiloNC is switched on. We need RTS active (low electrical level), a loop RTS on CTS is sufficient because CTS is active (low electrical level) once the HiloNC is switched on. F DCD and RI can stay not connected and floating. 3.6.5 Design impact on DTR usage The designer must consider when choosing V24 design that DTR can be used for several purposes : flow control of V24 interface (see chapter 3.6.2) enter/exit sleep mode of HiloNC module if AT+KSLEEP=0 has been configured (see chapter 3.14) switch between command/data modes 3.7 Depending of the HiloNC/Host V24 connexion, the DTR can be usable by customer or not (if always connected to DSR) and then has impact on sleep mode management and AT command/data modes management. SPI HiloNC module manages a host SPI interface. This SPI interface is dedicated for trace. Sagem Communications strongly recommends leaving this interface externally accessible for trace (e.g. access by test point pads). Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 20/36 3.8 GPIO There are five GPIOs available on HiloNC. The GPIO1, GPIO2 and GPIO3 have internal pull-up resistors while GPIO4 and GPIO5 are open collector. and GPIO5 are used as output, they must be pulled up to VGPIO. The typical value of the pullF IfupGPIO4 resisters is 100K ohms. 3.9 BACKUP BATTERY 3.9.1 Backup battery function feature 3.9.1.1 With backup battery A backup battery can be connected to the module in order to supply internal RTC (Real Time Clock) when the main power supply is removed. Thus, when the main power supply is removed, the RTC is still supplied and the module keeps the time running. With external backup battery: If VBAT < 3V, internal RTC is supplied by VBACKUP. If VBAT > =3V, internal RTC is supplied by VBAT. 3.9.1.2 Without backup battery Without backup battery If VBAT > 1.5V, internal RTC is supplied by VBAT. If VBAT < 1.5V, internal RTC is not supplied. FVBACKUP input of the module has to be connected to a 10µF capacitor (between VBACKUP and GND). SAGEM does not recommend to connect VBACKUP signal to VBAT. However, if VBACKUP has been connected to VBAT, this has no influence if VBAT is between 3.2V and 4.2V. For VBAT above 4.2V the module can take a longer time to start at low temperature. 3.9.2 Current consumption on the backup battery When the power supply is removed, the internal RTC will be supplied by backup battery. To calculate the backup battery capacity, consider that Current consumption for RTC on the backup battery is below 2,6µA depending on the temperature. Pin Name VBACKUP Min Max 2.6µA 3.9.3 Charge by internal HiloNC charging function The charging function is available on the HiloNC without any additional external power supply (the charging power supply is provided by the HiloNC). F Charge of the back-up battery occurs only when main power supply VBAT is provided. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 21/36 The recommended schematic is given hereafter: VBACKUP HiloNC Figure 17: Backup battery internally charged The resistor R depends on the charging current value provided by the battery manufacturer. The charging curve which is done by the HiloNC is given hereafter: Figure 18: Charging curve of backup battery 3.9.4 Backup Battery technology recommended 3.9.4.1 Manganese Silicon Lithium-Ion rechargeable Battery Sagem Communications does not recommend using this kind of technology because of the following drawbacks: • The maximum discharge current is limited (Shall be compliant with the module characteristics). • The over-discharge problem: most of the Lithium Ion rechargeable batteries are not able to recover their charge when their voltage reaches a low-level voltage. To avoid this, it is necessary to add a safety component to disconnect the backup .battery in case of over–discharge condition. In such a case, this implementation is too complicated (too much components for that function). • The charging current has to be regulated. F Sagem Communications does not recommend using this kind of backup battery technology. 3.9.4.2 Capacitor battery These kinds of backup battery have not the drawbacks of the Lithium Ion rechargeable battery. As there are only capacitors: Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 22/36 · The maximum discharge current is generally bigger, · There is no problem of over-discharge: the capacitor is able to recover its full charge even if its voltage has previously fallen to 0V. · There is no need to regulate the charging current. Moreover, this kind of battery is available in the same kind of package than the Lithium Ion cell and fully compatible on a mechanical point of view. The only disadvantage is that the capacity of this kind of battery is significantly smaller than Manganese Silicon Lithium Ion battery. But for this kind of use (supply internal RTC when the main battery is removed), the capacity is generally enough. F Sagem Communications strongly recommends using this kind of backup battery technology. 3.10 HARDWARE POWER MANAGEMENT AND MULTIPLEXING INTERFACES In case hardware power management and multiplexing are used, it is necessary to isolate host and HiloNC module in order not to generate current re-injection when HiloNC is switched-off. Typical schematic (only useful signals are represented): VGPIO Buffer Tri-state command DTR, RTS, RXD HiloNC Host DCD, DSR, CTS, TXD, RI Solution 1 Solution 2 Figure 19: Hardware interface between HiloNC and host In general, solution1 is enough to protect HiloNC module. 3.11 STARTING THE MODULE First power up VBAT, which must be in the range 3.2V – 4.5V, and able to provide 2.2A during the TX bursts (Refer to the module specification for more details). To start the module, a low level pulse must be sent on POK_IN during 1 s minimum (at 25°C). After a few seconds, the module puts in active state CTS when it is ready to receive AT commands. 3.12 MODULE RESET To reset the module, a low level pulse must be sent on RESET pad during 10 ms. 3.13 MODULE SWITCH OFF AT command “AT*PSCPOF” allows to switch off the module. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 23/36 3.14 SLEEP MODE MANAGEMENT AT command “AT+KSLEEP” allows to configure the sleep mode. When AT+KSLEEP=1 is configured : · the HiloNC module decides by itself when it enters in sleep mode (no more task running). · “0x00” character on serial link wakes up the HiloNC module. When AT+KSLEEP=0 is configured : · the HiloNC module is active when DTR signal is active (low electrical level). · when DTR is deactivated (high electrical level), the HiloNC module enters in sleep mode after a while. · on DTR activation (low electrical level), the HiloNC module wakes up. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 24/36 4. MANDATORY POINTS FOR THE FINAL TESTS AND TUNING The design of the customer’s board (on which the module is soldered) must provide an access to following signals when the final product will be completely integrated. To upgrade the module software, Sagem Communications recommends providing a direct access to the module serial link through an external connector or any mechanism allowing the upgrade of the module without opening the whole product. Serial link: TXD RXD Output Input UART transmit UART receive debug the module software, Sagem Communications recommends providing a direct access to the F Tomodule debug port SPI (5 I/Os) through internal test points (TP) located on the customer's main board. 5. ESD & EMC RECOMMENDATIONS 5.1 HILONC ALONE The HiloNC module alone can hold 2KV on each of the 51 pads including the RF pad. 5.2 CUSTOMER’S PRODUCT WITH HILONC If customer’s design must stand more than 2kV on electrostatic discharge, following recommendation must be taken into account. 5.2.1 Analysis ESD current can penetrate inside the device via the typical following components: · SIM connector · Microphone · Speaker · Battery / data connector · All pieces with conductive paint (plastron, special keys, etc...) In order to avoid ESD issues, efforts shall be done to decrease the level of ESD current on electronic components located inside the device (customer’s board, input of the HiloNC module, etc…) 5.2.2 Recommendations to avoid ESD issues F Insure good ground connections of the HiloNC module to the customer’s board. F Flex (if any) shall be shielded and FPC connectors shall be correctly grounded at each extremity. capacitor 100nF on battery (not on charger), or better put varistor or ESD diode in parallel on battery F Put and charger wires and on all wires on bottom connector. Uncouple microphone and speaker by putting capacitor or varistor in parallel of each wire of these devices. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 25/36 6. RADIO INTEGRATION 6.1 ANTENNA - Antenna contact • 50Ω line matching (between module and customer’s board, and with RF test point) Figure 20: Antenna connection Keep matching circuit on customer’s board but with direct connection in the first step – it could be necessary to make some adjustment later, during RF qualification stage. selected antenna must comply with FCC RF exposure limits in GSM850 and PCS1900 band : F- TheGSM850 : MPE < 0.55mW/cm (Distance is 20 cm) 6.2 PCS1900 : ERP < 3W GROUND LINK AREA Sagem Communications emphasizes the fact that a good ground contact is needed between the module and the customer’s board to have the best radio performances (spurious, sensitivity…). F All HiloNC GND pads must be connected to the GND of the customer’s board. 6.3 LAYOUT Warning : Isolate RF line and antenna from others bus or signals F No signals on 50 ohms area and if that is not possible, add ground shielding using different layers. F Do not add any ground layer under the antenna contact area. F Be careful on the position of the network LED (sometimes situated in front of the antenna pad ...) Do not put any via and lines on all the forbidden area under the module, shown as the grey area on the F figure below. Varnish must be present on all the grey area (expect solder pads) to isolate HiloNC module from the customer’s board. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 26/36 Figure 21: Forbidden area for via and lines 6.4 MECHANICAL SURROUNDING F Avoid any metallic part around the antenna area F Keep jacks, FPCs and battery contact far from antenna area (FLEX) F FPC has to be a shielded one 6.5 OTHER RECOMMENDATIONS – TESTS FOR PRODUCTION/DESIGN Sagem Communications guarantees the RF performances in conductive mode but strongly recommends making RF measurements in an anechoic chamber in radiated mode (tests conditions for FTA): the radiated performances strongly depend on radio integration (layout, antenna, matching circuit, ground area…..) 7. AUDIO INTEGRATION Audio mandatory tests for FTA are in handset mode only so a particular care must be brought to the design of audio (mechanical integration, gasket, electronic) in this mode. The audio norms which describe the audio tests are 3GPP TS 26.131 & 3GPP TS 26.132. Please note that acoustic competences are mandatory to get accurate audio performance on customer’s product. 7.1 MECHANICAL INTEGRATION AND ACOUSTICS Particular care to Handset Mode: FTA Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 27/36 To get a better audio output design (speaker part) : F The speaker must be completely sealed on front side. F The front aperture must be compliant with speaker supplier’s specifications F The back volume must be completely sealed. F The sealed back volume must be compliant with speaker supplier’s specifications F Take care of the design of the speaker gasket (elastomer). F Foresee a stable and large enough area for the gasket of the artificial ear. To get a better audio input design (microphone part) : F Take care of the design of the microphone (elastomer). F All receivers must be completely sealed on front side. F Microphone sensitivity depends on the shape of the device eg. about –40 ±3 dBV/Pa for clamshell. F Promote the use of pre-amplified microphone. If needed, use a pre-amplification stage. As audio input and ouput are strongly linked : F Place the microphone and the speaker as far as possible from one another. 7.2 ELECTRONICS AND LAYOUT Avoid Distortion & Burst noise F Audio signals must be symmetric (same components on each path). F Differential signals must be routed parallel. F Audio layer must be surrounded by 2 ground layers. F The link from one component to the ground must be as short as possible. F If possible separate the PCB of the microphone and the one of the speaker. F Reduce as much as possible the number of electronics components (loss of quality, more dispersion). F Audio tracks must be larger than 0.5 mm. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 28/36 8. RECOMMENDATIONS ON LAYOUT OF CUSTOMER’S BOARD 8.1 GENERAL RECOMMENDATIONS ON LAYOUT There are many different types of signals in the module which are disturbing each other. Particularly, Audio signals are very sensitive to external signals as VBAT(1).... Therefore it is very important to respect some rules to avoid disruptions or abnormal behaviour. 8.1.1 Ground F A ground plane as complete as possible Ground of components has to be connected to the ground layer through many vias not regularly F distributed. F Top and bottom layer shall have as much as possible of ground planes. 8.1.2 Power supplies F Plan for power supply signals (VBAT, VGPIO), no loop. F Suitable power supply (VBAT, VGPIO) track width, thickness. 8.1.3 Clocks F Clock signals must be shielded between two grounds plans and bordered with ground vias. 8.1.4 Data bus and other signals bus and commands have to be routed on the same plane, none of the lines of the bus shall be F Data parallel to other lines F Lines crossing shall be perpendicular F Suitable other signals track width, thickness. F Data bus must be protected by upper and lower ground plans 8.1.5 Radio F Provide a 50 Ohm microstrip line for antenna connection 8.1.6 Audio (see also § 10.2) F Differential signals have to be routed together, parallel (for example HSET_OUT_P/HSET_OUT_N). F Audio signals have to be isolated, by pair, from all the other signals (ground all around each pair). any loops between VBAT and GND next to the speaker to avoid the TDMA burst noise in the F Cancel speaker during a communication. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 29/36 F The single-end audio signal should be adopted the same rules as differential signals. GND HSET_OUT_P HSET_OUT_N GND Figure 22: Layout of audio differential signals on a layer n GND Layer n-1 Layer n HSET_OUT_P Layer n+1 GND Figure 23: Adjacent layers of audio differential signals (1). Warning: Magnetic field generated by VBAT tracks may disturb the speaker, causing audio burst noise. In this case, one shall modify routing of the VBAT tracks to reduce the phenomena. 8.2 EXAMPLE OF LAYOUT FOR CUSTOMER’S BOARD The figure Figure 24 shows an example of layer allocation for a 6 layers circuit (for reference only): Layer 1: Components (HiloNC) Layer 2: Bus Layer 3: Power supply Layer 4: Complete GND layer Layer 5: Audio, clocks, sensitive signals Layer 6: GND,test points Figure 24: layer allocation for a 6 layers circuit 9. RECOMMANDATIONS FOR CUSTOMER INDUSTRIALIZATION Please note for following chapters that except where standards are indicated, the given characteristics should be considered as validated conditions used on Sagem Communication product. Other conditions depending of the customer’s factory process are not validated but can be submitted to Sagem Communication for proficiency. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 30/36 9.1 MOISTURE LEVEL According to IPC/JEDEC J-STD 20, the HiloNC has the following MSL level : 3 (Targeted). Level Floor Life Time 168 hours Conditions <= 30°C/60% RH Soak requirements Standard Accelerated Equivalent Time (hours) Conditions Time (hours) Conditions 192 +5/-0 30°C / 60% RH 40 +1/-0 60°C / 60%RH It means that the customer’s factory must process and solder the HiloNC on the customer’s board at least 168 hours (7 days) after the HiloNC sealed package have been opened. This duration is given for factory floor conditions of T°<30°C, HR 60%. F If this duration can not be fulfilled, the HiloNC part must be baked again. 9.2 PACKAGE The HiloNC module is delivered in Tape and Reel package which is hermetically sealed to prevent from moisture and ESD. The characteristics of the T&R are given in the drawing below. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 31/36 Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 32/36 9.3 SOLDER MASK Below are given soldering characteristics to report the HiloNC on the customer’s board. Copper footprint is shown in yellow on the figure below. Solder mask footprint is shown in pink. F Please note that copper mask and solder mask do not strictly recover themselves. Figure 25 : Solder mask design 9.4 SOLDER PASTE Solder paste : Alloy composition : Melting temperature : M705-GRN360-K-V (Senju Metal Industry Co., Ltd.) Sn96.5-Ag3.0-Cu0.5 solidus 216°C / Peak 217°C / liquidus 220°C F Sagem Communication recommends a stencil thickness of 135 µm. 9.5 PROFILE FOR REFLOW SOLDERING A convection type soldering oven is recommended. Typical usable profile is shown on the next figure. The final profile has to be tuned depending on other elements like solder paste, customer’s board, other components,… Peak temperature : Average ramp up rate : Average ramp down rate : 245°C 3°C/second max TBC Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 33/36 Figure 26 : Typical thermal profile The HiloNC module is a Lead-free product which has been validated integrated in a lead-free product, using a lead-free factory process. test has been performed using a leaded process. Sagem Communication does not recommend to use a factory leaded process and does not guarantee any F No reliable result on the final product. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 34/36 9.6 SMT MACHINE HiloNC is optimized for use with pick-and-place machines.Optical inspection for placement is possible with SMD fiducials placed on the bottom side of the HiloNC. SMD fiducials are not symmetrical in order to help optical inspection to define the right orientation. Figure 27 : CMS fiducials positions 9.7 UNDERFILL Despite its important reliability, some customer could request for some specific and extreme applications the underfill of onboard components. The HiloNC’s shield has be designed accordingly to allow this process, as shown in the figure below. More details will be given in a specific application note. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 35/36 Underfill Holes Figure 28 : Underfill holes 9.8 SECOND REFLOW SOLDERING Even if Sagem Communications recommends a single reflow soldering, a second reflow soldering can be conceivable (only if underfill has not been already performed). Positive tests have been performed with HiloNC on the bottom side. F Second reflow soldering is not possible if HiloNC module has been already underfilled. 9.9 HAND SOLDERING Hand soldering is possible. 9.10 An especial care must be considered to properly position the HiloNC on its copper footprint during hand soldering. Begin with pads diagonally opposite to help in proper positioning. REWORK Rework is possible, for repair purpose for example. F An especial care must be considered in order not to overheat the HiloNC. 10. LABEL The HiloNC module is labelled with its own FCC ID(VW3HILONC) on its bottom side. When the module is installed in customer’s product, the FCC ID label on the module will not be visible. To avoid this case, an exterior label must be stuck on the surface of customer’s product signally to indicate the FCC ID of the enclosed module. This label can use wording such as the following: “Contains Transmitter module FCC ID: VW3HILONC” or “Contains FCC ID: VW3HILONC”. Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited page 36/36 Note d’étude / Technical document : URD1– OTL 5665.1– 002 / 70 884 Edition 03 Document Sagem Communications Reproduction et divulgation interdites Sagem Communications document. Reproduction and disclosure prohibited
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Fill forms, Print high-res Title : HiloNC User Manual Author : James_Xia Creator : pdfFactory Pro www.pdffactory.com Producer : pdfFactory Pro 2.51 (Windows XP Professional Chinese) Create Date : 2009:04:27 16:17:48+08:00 Page Count : 36EXIF Metadata provided by EXIF.tools