SALUS North America AKL01PRF ZigBee Zone Pump Wiring Center User Manual

SALUS North America, Inc. ZigBee Zone Pump Wiring Center

User manual

Download: SALUS North America AKL01PRF ZigBee Zone Pump Wiring Center User Manual
Mirror Download [FCC.gov]SALUS North America AKL01PRF ZigBee Zone Pump Wiring Center User Manual
Document ID3438718
Application IDq1CY8keXFo9nwiKPbuFfKw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize75.13kB (939071 bits)
Date Submitted2017-06-25 00:00:00
Date Available2017-06-25 00:00:00
Creation Date2017-05-02 13:26:23
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-06-21 15:33:43
Document TitleUser manual
Document CreatorAdobe InDesign CC 2017 (Macintosh)

AKL01PRF ZigBee Zone Pump Wiring Center
Wiring Guide
LED Indicators
Electrical Connections
Dry Contacts (rated 120VAC, max.2A)
XX
Active Pump
120VAC Connections
AC Line In
Zone Pump Line Out (max. 1/6 HP)
AC Neutral
Earth Ground
Color Meaning
Power
120 VAC power ON
Zone 1
Zone pump active
Network
Status
Searching for
network
Paired to a network
Fuse: 5A slow blow, 5x15mm (2AG)
Wiring Center ID Number
Operational Summary
Zone Pump
The zone pump will be
the thermostat calls for heat.
Name
Zone LED Pattern:
activated
when
Auxiliary Output
XX: Contact closure when zone pump is ON.
Factory Default
To restore the wiring center to Factory Default,
press and hold the Pair button until the
Network Status LED turns off (~10 secs).
Note: Restoring to Factory Default will remove
the wiring center from the network and delete
all associated devices.
short=1, long=3
WCID#
Warning
• This product must be installed by qualified personnel and the installation must comply with the codes and regulations applicable to the
municipality where this product is installed. Failure to do so could lead to injury, death, or prosecution.
• Always disconnect the AC power before installing or working on AC power components.
For PDF Installation guide go to
www.salusinc.com
Technical Helpline 1-855-557-2587
Issue Date: May 2017
AKL01PRF ZigBee Zone Pump Wiring Center
Installation Guide
Remove the plastic
cover by unscrewing
the 4 screws at the
corners.
Attach the back of
the AKL01PRF to the
wall or in a suitable
location, using the
included hardware.
Disconnect the
AC power to the
AC wiring for the
device.
Wire the device to the AC power
supply and zone pump using wiring
appropriate for 120VAC. Connect the
other terminals as appropriate to the
other devices using proper wiring. Be
sure to thread wiring through the knock
outs and use cable clamps to fasten the
wiring to the device.
Pump Power
Boiler
Make sure that the fuse
is 5A, slow blow and
inserted correctly.
If you need an external
antenna, please follow the
instructions to the right for
External Antenna Installation.
Re-attach the plastic cover, securing it with the 4 screws and switch
on the AC power to the unit. The Power LED will come on.
The EFWJDF JT OPX rFBEZ UP DPOOFDU UP UIF OFUXPSL
'PMMPX UIF TUFQT GPS the selected type of OFUXPSL UP BEE UIF
EFWJDF UP UIF OFUXPSL using the Pair button on the top of the
device as required.
Local Only Network using ZigBee Coordinator
1. Plug the Coordinator into a centrally located outlet
in the home if you have not already done so.
2. Press and hold the button on the Coordinator
until the button flashes red (about five second).
- The Coordinator is now ready to pair and is
looking for devices.
- The Network Status LED on each wiring center will go
steady red when connected to the Coordinator. One
Coordinator can support up to nine wiring centers.
3. Determine the network ID number for a wiring center by
pressing the Pair button briefly and counting the flashes
of the Zone LED (see WCID# chart under LED Indicators).
4. Pair and setup the Salus thermostats according to the
thermostat manual, using the wiring center ID number
determined in the previous step.
5. When all thermostats are setup, press and hold the
button on the Coordinator until the button is steady red
(about five seconds).
$IFDLJOH 4ZTUFN $POGJHVSBUJPO BOE $PNNVOJDBUJPO
Coordinator to Wiring Centers
Press and hold the coordinator button for one second.
All devices connected to the coordinator will flash. For
the wiring center, the Network Status and Zone 1 LEDs
will flash. To stop checking, press and hold the coordinator
button again for one second.
Wiring Center to Thermostat
Press and hold the Pair button until the Network Status and
Zone 1 LEDs flash (about 3 seconds), and the associated
thermostat will flash its display. To exit Identify mode, press
and hold the Pair button again until the Network Status is
steady red.
Internet Connected Network using Basic Gateway
1. Setup the Basic Gateway as instructed and associate the
gateway with the wyse.ly service account.
2. Go to the "EE/FX&RVJQNFOU page on the wyse.ly
app and press "Scan for equipment".
- The gateway ring will flash red
indicating that it is looking for devices.
3. Use the wyse.ly app to add the wiring
centers to your wyse.ly network.
- The Network Status LED on each wiring center will go
steady red when connected to the Basic Gateway.
4. Use the wyse.ly app to add the Salus thermostats to your
network and associate them with the desired wiring
center and zone.
5. When all devices are setup, exit the "EE /FX
&RVJQNFOU function on the wyse.ly app.
- The gateway ring will turn steady blue to indicate
normal operating mode.
$IFDLJOH 4ZTUFN $POGJHVSBUJPO BOE $PNNVOJDBUJPO
(BUFXBZUP8JSJOH$FOUFS
Go to the Wyse.ly App and press the Identify button for the
desired wiring center. The desired wiring center will start
flashing the Network Status and Zone 1 LEDs. To stop the
identify process, press the Identify button on the App again.
Gateway to Thermostat
Go to the Wyse.ly App and press the Identify button for the
desired thermostat. The desired thermostat will start
flashing its display. To stop the identify process, press the
Identify button on the App again.
External Antenna Installation
If you need to install an external antenna, perform the following:
• Disconnect power
• Remove the protective cover from the External Antenna connector
on the bottom edge of the board.Pass the antenna cable through
the antenna knock out (and cable clamp) on the bottom of the
housing and screw the cable onto the connector.
• Secure the cable using a cable clamp.
• Change the Antenna Selection switch from INT to EXT.
• Reconnect power
The device will now use the external antenna for wireless
communication.
Note: For regulatory compliance, only the Salus A8RFA antenna
(type G-MA0G29027125-C0128,gain 2.15dBi, made by Bondale
Electronics Ltd., sold separately) can be used with this device.
FCC/IC Statements and Notices
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receive is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC and Industry Canada
RF Radiation Exposure statement: This equipment complies with FCC and Industry Canada RF radiation
exposure limits set forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 centimeters between the antenna and all persons.
Cet appareil est conforme aux limites d’exposition au rayonnement FR du FCC et d’Industrie Canada pour
un environnement non contrôlé. Cet appareil devrait être installé et devrait fonctionner de sorte qu’il se
trouve à une distance d’au moins 20 cm entre l’antenne et toute personne.
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes : 1) l’appareil ne doit pas produire de
brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2017:05:02 13:26:23+03:00
Creator                         : Adobe InDesign CC 2017 (Macintosh)
Modify Date                     : 2017:06:21 15:33:43+08:00
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Metadata Date                   : 2017:06:21 15:33:43+08:00
Instance ID                     : uuid:85fbe12c-bce6-4f3c-b6ec-951dbbb95298
Original Document ID            : xmp.did:74cb1a14-5609-4933-ad81-99196535e463
Document ID                     : xmp.id:ced153a6-0a76-4634-af5b-286ed105ffea
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:081ffd3c-c14d-48dc-9f10-4eb9b0e5d118
Derived From Document ID        : xmp.did:a0369d75-b676-4c7c-99c9-37cabf77153d
Derived From Rendition Class    : default
History Action                  : converted, converted, converted
History Parameters              : from application/x-indesign to application/pdf, converted to PDF/A-2b, converted to PDF/A-2b
History Software Agent          : Adobe InDesign CC 2017 (Macintosh), Preflight, Preflight
History When                    : 2017:05:02 13:26:23+03:00, 2017:05:03 01:08:27-07:00, 2017:05:03 01:13:03-07:00
History Instance ID             : uuid:c3ebef36-4387-5344-ba91-fcb5a674b68d, uuid:c633717a-04ce-ca47-bae8-1c24f8bb1ea7
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Schemas Namespace URI           : http://www.aiim.org/pdfa/ns/id/
Schemas Prefix                  : pdfaid
Schemas Schema                  : PDF/A ID Schema
Schemas Property Category       : internal
Schemas Property Description    : Conformance level of PDF/A standard
Schemas Property Name           : conformance
Schemas Property Value Type     : Text
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AG86-AKL01PRF

Navigation menu