801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS FS23M, 1090, 1190 SERIES OVERHEAD INSTALLATION HORIZONTAL 1. Examine the top rail of the door for the most suitable location for the strike. Mark the door for the end of the strike closet to the lock stile, and make a corresponding mark on the header to line up with the first mark. 2. Locate center line of door thickness on the header and attach adhesive cut out template to header. Lining it up with marks, center punch the tab-mounting screw locations and counter-sink for #10 screw. Saw or rout out the cutout area. SIDEJAMB INSTALLATION VERTICAL 3. Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike. Mark the door stile horizontal for the top end of the strike and make a corresponding mark on the jamb. 4. Locate center line of door thickness on the jamb and attach adhesive cutout template to jamb, lining up the the top of the cutout with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10 screw. Saw or rout the cutout 1-1/2” x 8”. 5. Attach the mounting tabs inside. 6. (FS23M only) bore 5/16” hole for pilot lamp on inside face of frame as shown. 7. Attach power supply leads to lock leads as shown. Handle the lock carefully; do not hang it by the wire leads. Insert wires into the header cavity carefully so they do not interfere with proper locating of the lock in the cutout. 8. Insert lock. Horizontally, the bolt end is nearest the lock stile. Vertically, the bolt must be at the top end of the cutout. Secure with 10/32 machine screw. 9. Using strike for a template, mark screw hole location and drill holes for screws supplied. Mortise as required. Attach strike. 10. The automatic relock switch is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any additional gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper adjustment is reached. Be sure to tighten lock nut when adjustment is satisfactory. Auto Relock Switch Adjustable for Wide Door Gap Loosen nut. Turn assembly clockwise for wide door gap. Tighten nut. Fig. 1 Easy Installation or Servicing All Space Saver locks are easily installed in any existing entrance merely by mortising out a cutout, attaching the wiring, inserting the lock, and bolting it into position with two attaching tabs. Cutting studs is no longer a problem or expense. Fig. 2 1. Mortise cutout in tube for face plate (fits flush with surface of tube). 3. Connect wiring to lock. 4. Slide lock into position, attach to tabs. 2. Position screws for attaching tabs, drill holes, attach tabs. P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd REV E 06-13 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com 1190A FOR 1190A ONLY: Face plate: 8” x 1-1/2” x 0.125” (203.2mm x 38.1mm x 3.175mm) I.D. Requirements: 8” x 1-1/2” x 1-1/2” (203.2mm x 38.1mm x 38.1mm) A.R.S. RED WHT YEL YEL N.O. Solenoid: Continuous duty Standard voltage: 24VDC @ .7 Amp Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm) Bolt: 3/4” (6.35mm) dia. S.S., 3/4” (6.35mm) throw ACCESS CONTROLS N.C. N.C. DOOR IS SHOWN CLOSED AND LOCKED. POWER FS23M UNLOCKING MAY BE CONTROLLED BY MULTIPLE SWITCH LOCATIONS. FOR FS23M AND 1091A/1091ADC: Face plate: 8” x 1-1/2” x 1/8” (203.2mm x 38.1mm x 3.175mm) I.D. Requirements: 8” x 1-1/2” x 1-1/2” (203.2mm x 38.1mm x 38.1mm) YEL YEL RED BLK BLU WHT ARS Solenoid: Continuous duty Dual Voltage: 12VDC@ .9 Amp 24VDC@ .45 Amp 12 VDC CONFIGURATION Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm) For wood 1-3/4” deep (44.45mm) Bolt: 5/8” (15.88mm) dia. nylon with magnet insert, 5/8” (15.88mm) throw. Red pilot lamp standard to indicate door locked. YEL YEL RED BLK BLU WHT 1091A/1091ADL (DEADLOCKING) Face plate: 8” x 1-1/2” 0.125” (35.1mm x 35.1mm x 3.175mm) 1091STA: 4-7/8” x 1-1/4” x 0.0937” ANSI (123.53mm x 31.75mm x 2.28mm) 24 V CONFIGURATION RED = N/C WHT = COM BLU = N/O I.D. Req. 8” x 1-1/2” x 1-1/2” (203.2mm x 38.1mm x 38.1mm) DPS RED = N/C WHT = COM BLU = N/O BPS Solenoid: Continuous duty Dual Voltage: 12VDC @ .9 AMP 24VDC @ .45 AMP CONTACT RATING 5 AMPS @ 125 VAC DPS / BPS CONFIGURATION Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 44.45mm) Bolt: 5/8” (15.88mm) dia. S.S., 3/4” (6.35mm) throw BOLT POSITION SENSOR (MAGNETIC) B Indicates bolt locked or unlocked .25 Amp DOOR POSITION SWITCH (MECHANICAL) D Indicates door opened or closed 5 Amp P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd TROUBLE SHOOTING Problem Solution Bolt does not project Check voltage and alignment of strike. Bolt projects but chatters Voltage too low. Bolt will not retract Strike misaligned REV E 06-13 Page 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : sdc-36 Create Date : 2013:06:28 12:56:13-07:00 Modify Date : 2013:06:28 13:42:35-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2013:06:28 13:42:35-07:00 Format : application/pdf Creator : sdc-36 Title : Visio-INST-90 DEG.vsd Document ID : uuid:f20930d8-7801-443c-88f3-7c708c4d1ec4 Instance ID : uuid:97394809-01c3-3146-ab76-f65da352263e Page Count : 2EXIF Metadata provided by EXIF.tools