INSTALLATION INSTRUCTIONS
FS23M, 1090, 1190 SERIES
OVERHEAD INSTALLATION HORIZONTAL
1.

Examine the top rail of the door for the most suitable location for the strike. Mark the door for the end of the strike closet to
the lock stile, and make a corresponding mark on the header to line up with the first mark.

2.

Locate center line of door thickness on the header and attach adhesive cut out template to header. Lining it up with marks,
center punch the tab-mounting screw locations and counter-sink for #10 screw. Saw or rout out the cutout area.

SIDEJAMB INSTALLATION VERTICAL
3.

Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike.
Mark the door stile horizontal for the top end of the strike and make a corresponding mark on the jamb.

4.

Locate center line of door thickness on the jamb and attach adhesive cutout template to jamb, lining up the the top of the
cutout with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10 screw.
Saw or rout the cutout 1-1/2” x 8”.

5.

Attach the mounting tabs inside.

6.

(FS23M only) bore 5/16” hole for pilot lamp on inside face of frame as shown.

7.

Attach power supply leads to lock leads as shown. Handle the lock carefully; do not hang it by the wire leads. Insert wires
into the header cavity carefully so they do not interfere with proper locating of the lock in the cutout.

8.

Insert lock. Horizontally, the bolt end is nearest the lock stile. Vertically, the bolt must be at the top end of the cutout. Secure
with 10/32 machine screw.

9.

Using strike for a template, mark screw hole location and drill holes for screws supplied. Mortise as required. Attach strike.

10. The automatic relock switch is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any
additional gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper
adjustment is reached. Be sure to tighten lock nut when adjustment is satisfactory.

Auto Relock Switch
Adjustable for Wide Door Gap
Loosen nut.
Turn assembly
clockwise for wide
door gap.
Tighten nut.
Fig. 1

Easy Installation or Servicing
All Space Saver locks are
easily installed in any existing
entrance merely by mortising
out a cutout, attaching the
wiring, inserting the lock, and
bolting it into position with two
attaching tabs. Cutting studs is
no longer a problem or
expense.

Fig. 2

1. Mortise cutout in
tube for face plate
(fits flush with
surface of tube).

3. Connect wiring
to lock.
4. Slide lock into
position, attach
to tabs.

2. Position screws
for attaching
tabs, drill holes,
attach tabs.

P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd

REV E

06-13

Page 1

Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com

1190A

FOR 1190A ONLY:

Face plate: 8” x 1-1/2” x 0.125”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)

A.R.S.
RED

WHT

YEL

YEL
N.O.

Solenoid: Continuous duty
Standard voltage: 24VDC @ .7 Amp
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
Bolt: 3/4” (6.35mm) dia. S.S., 3/4” (6.35mm) throw
ACCESS CONTROLS
N.C.

N.C.

DOOR IS SHOWN CLOSED AND LOCKED.
POWER

FS23M

UNLOCKING MAY BE CONTROLLED BY
MULTIPLE SWITCH LOCATIONS.

FOR FS23M AND 1091A/1091ADC:

Face plate: 8” x 1-1/2” x 1/8”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)

YEL
YEL
RED
BLK
BLU
WHT

ARS

Solenoid: Continuous duty
Dual Voltage:
12VDC@ .9 Amp
24VDC@ .45 Amp

12 VDC CONFIGURATION

Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
For wood 1-3/4” deep (44.45mm)
Bolt: 5/8” (15.88mm) dia. nylon with magnet insert, 5/8” (15.88mm)
throw.
Red pilot lamp standard to indicate door locked.

YEL
YEL
RED
BLK
BLU
WHT

1091A/1091ADL (DEADLOCKING)
Face plate: 8” x 1-1/2” 0.125” (35.1mm x 35.1mm x 3.175mm)
1091STA: 4-7/8” x 1-1/4” x 0.0937” ANSI
(123.53mm x 31.75mm x 2.28mm)

24 V CONFIGURATION

RED = N/C
WHT = COM
BLU = N/O

I.D. Req. 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)

DPS

RED = N/C
WHT = COM
BLU = N/O

BPS

Solenoid: Continuous duty
Dual Voltage:
12VDC @ .9 AMP
24VDC @ .45 AMP

CONTACT RATING
5 AMPS @ 125 VAC

DPS / BPS CONFIGURATION

Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 44.45mm)
Bolt: 5/8” (15.88mm) dia. S.S., 3/4” (6.35mm) throw

BOLT POSITION SENSOR (MAGNETIC)
B

Indicates bolt locked or unlocked

.25 Amp

DOOR POSITION SWITCH (MECHANICAL)
D

Indicates door opened or closed

5 Amp

P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd

TROUBLE SHOOTING
Problem
Solution
Bolt does not project
Check voltage and alignment
of strike.
Bolt projects but chatters

Voltage too low.

Bolt will not retract

Strike misaligned

REV E

06-13

Page 2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : sdc-36
Create Date                     : 2013:06:28 12:56:13-07:00
Modify Date                     : 2013:06:28 13:42:35-07:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2013:06:28 13:42:35-07:00
Format                          : application/pdf
Creator                         : sdc-36
Title                           : Visio-INST-90 DEG.vsd
Document ID                     : uuid:f20930d8-7801-443c-88f3-7c708c4d1ec4
Instance ID                     : uuid:97394809-01c3-3146-ab76-f65da352263e
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu