INSTALLATION INSTRUCTIONS
FS23M, 1090, 1190 SERIES
OVERHEAD INSTALLATION HORIZONTAL
1. Examine the top rail of the door for the most suitable location for the strike. Mark the door for the end of the strike closet to
the lock stile, and make a corresponding mark on the header to line up with the first mark.
2. Locate center line of door thickness on the header and attach adhesive cut out template to header. Lining it up with marks,
center punch the tab-mounting screw locations and counter-sink for #10 screw. Saw or rout out the cutout area.
SIDEJAMB INSTALLATION VERTICAL
3. Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike.
Mark the door stile horizontal for the top end of the strike and make a corresponding mark on the jamb.
4. Locate center line of door thickness on the jamb and attach adhesive cutout template to jamb, lining up the the top of the
cutout with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10 screw.
Saw or rout the cutout 1-1/2” x 8”.
5. Attach the mounting tabs inside.
6. (FS23M only) bore 5/16” hole for pilot lamp on inside face of frame as shown.
7. Attach power supply leads to lock leads as shown. Handle the lock carefully; do not hang it by the wire leads. Insert wires
into the header cavity carefully so they do not interfere with proper locating of the lock in the cutout.
8. Insert lock. Horizontally, the bolt end is nearest the lock stile. Vertically, the bolt must be at the top end of the cutout. Secure
with 10/32 machine screw.
9. Using strike for a template, mark screw hole location and drill holes for screws supplied. Mortise as required. Attach strike.
10. The automatic relock switch is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any
additional gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper
adjustment is reached. Be sure to tighten lock nut when adjustment is satisfactory.
1. Mortise cutout in
tube for face plate
(fits flush with
surface of tube).
2. Position screws
for attaching
tabs, drill holes,
attach tabs.
4. Slide lock into
position, attach
to tabs.
3. Connect wiring
to lock.
P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd REV E 06-13 Page 1
Easy Installation or Servicing
All Space Saver locks are
easily installed in any existing
entrance merely by mortising
out a cutout, attaching the
wiring, inserting the lock, and
bolting it into position with two
attaching tabs. Cutting studs is
no longer a problem or
expense.
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Fig. 2
Auto Relock Switch
Adjustable for Wide Door Gap
Loosen nut.
Turn assembly
clockwise for wide
door gap.
Tighten nut.
Fig. 1
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd REV E 06-13 Page 2
1190A
Face plate: 8” x 1-1/2” x 0.125”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Standard voltage: 24VDC @ .7 Amp
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
Bolt: 3/4” (6.35mm) dia. S.S., 3/4” (6.35mm) throw
1091A/1091ADL (DEADLOCKING)
Face plate: 8” x 1-1/2” 0.125” (35.1mm x 35.1mm x 3.175mm)
1091STA: 4-7/8” x 1-1/4” x 0.0937” ANSI
(123.53mm x 31.75mm x 2.28mm)
I.D. Req. 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Dual Voltage:
12VDC @ .9 AMP
24VDC @ .45 AMP
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 44.45mm)
Bolt: 5/8” (15.88mm) dia. S.S., 3/4” (6.35mm) throw
FOR FS23M AND 1091A/1091ADC:FS23M
Face plate: 8” x 1-1/2” x 1/8”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Dual Voltage:
12VDC@ .9 Amp
24VDC@ .45 Amp
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
For wood 1-3/4” deep (44.45mm)
Bolt: 5/8” (15.88mm) dia. nylon with magnet insert, 5/8” (15.88mm)
throw.
Red pilot lamp standard to indicate door locked.
FOR 1190A ONLY:
DOOR IS SHOWN CLOSED AND LOCKED.
UNLOCKING MAY BE CONTROLLED BY
MULTIPLE SWITCH LOCATIONS.
RED
POWER
N.C.
ACCESS CONTROLS
N.O.
A.R.S.
YELYELWHT
N.C.
TROUBLE SHOOTING
Problem Solution
Bolt does not project Check voltage and alignment
of strike.
Bolt projects but chatters Voltage too low.
Bolt will not retract Strike misaligned
BOLT POSITION SENSOR (MAGNETIC)
B Indicates bolt locked or unlocked .25 Amp
DOOR POSITION SWITCH (MECHANICAL)
D Indicates door opened or closed 5 Amp
ARS
YEL
YEL
12 VDC CONFIGURATION
RED
BLK
BLU
WHT
YEL
YEL
RED
BLK
BLU
WHT
24 V CONFIGURATION
RED = N/C
WHT = COM
BLU = N/O
CONTACT RATING
5 AMPS @ 125 VAC
RED = N/C
WHT = COM
BLU = N/O
DPS
DPS / BPS CONFIGURATION
BPS