INSTALLATION INSTRUCTIONS
E1200 SERIES MAGNETIC LOCK

Interlocking
Mounting Plate
Quick Mount
Interlocking
Mounting Assembly

Frame

Mounting Screws
Armature

Outswing

Electrical Instructions:
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.

Electrical Specifications:

Although SDC recommends the use of a DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier
may be used. A significant drop will occur when using a full wave
bridge rectifier.

Power Consumption

Any low voltage condition will cause erratic operation of the
optional board sensor.

Dual Voltage

12 or 24VDC
.500mA@12VDC
250mA@24VDC

DS Door Status Sensor SPDT, 500mA@30VDC
LS Lock Status Sensor SPDT, 2A@30VDC

When using a full wave bridge rectifier all access controls and/or
release contacts must be located between the EMlock and rectifier
to ensure quick release.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd

REV A1

04-11

Page 1

Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com

1. Inspect the frame header to determine if mounting accessories are required (refer to page 4).
2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the
lock jamb side of the frame.
3. Mark and drill holes as indicated by the template.

STEPS 2 & 3

4. Mount armature to door.

STEEL WASHER 2X

STEP 4

5/16-18 SOC HD
SCREW
WITH 3/16 (5MM)
ALLEN HEX

ARMATURE

REINFORCEMENT
TUBE

1-3/4“ HOLLOW
METAL DOOR

5/8“ DRILL

1/2” DRILL
SEXNUT

RUBBER WASHER

HOLLOW METAL DOOR
From Sexnut side of door, drill exactly 1/2” hole thru one metal
thickness only. From Armature side of door, drill 5/8” hole to insert
reinforcement tube. Press in sexnut and reinforcement tube all the
way and mount armature to door using hardware provided.

5. Install magnet onto the header with the magnetic stripes towards the door side of the stop.
Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.

STEP 5

P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd

REV A1

04-11

Page 2

6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the
door. Tap with a soft hammer to ensure proper alignment and engagement.
CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head
screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the
threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing

STEP 6

7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.
SWITCH or
ACCESS
CONTROL
2 3
- NO

A/C
MAINS

4
C

Lock
Status
Switch
(Relay)

+

1
+

Power
Supply

5
6
NC NO
7 8
C NC

Door
Position
Sensor

POWER
SUPPLY

-

12VDC
or
24VDC

R
G
B
W

ATTACH THE RED SIDE OF THE CONNECTOR HERE
FOR A GREEN LED ENERGIZED & SECURE (RED=ENERGIZED & UNSECURE)

G
B
R

LED

RED
GRN
ATTACH THE GREEN SIDE OF THE CONNECTOR HERE
FOR A RED LED ENERGIZED AND UNSECURE (GREEN=ENERGIZED & SECURE)

Voltage Jumper

12VDC

24VDC

Door Position Sensor (Reed switch)
NC
COM
RED (open with door closed)
BLACK
GREEN (closed with door closed)
NO

8. Test operation. When all is operating properly, tighten
all screws as shown. Install security pins and screws
as shown. Install anti-tamper plugs over socket head
screws using a soft hammer to avoid damage to the housing.

P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd

REV A1

04-11

Page 3

MOUNTING ACCESSORIES:

STOP FILLER PLATE
EF02
Inches: 10.5" L x 0.5" H x 0.75" D
mm: 266 L x 12.7 H x 19 D

GLASS DOOR ARMATURE BRACKET
E12U
For use with Model E600 Series
Field adjustable for glass thickness

ANGLE BRACKET
E12L
Inches: 10.5" L x 0.5" H x 0.75" D
mm: 266 L x 12.7 H x 19 D

TOP JAMB MOUNTING BRACKET
E12Z
For use with Model E1200 Series

ADJUSTABLE ANGLE BRACKET
E12A
For use with Model E1200 Series

Supplied Mounting Hardware

To maintain surface plating from corrosion:
Do not touch the lock face with your hands.
Clean lock face with Scotch-Brite pad by 3M (do not use
sandpaper).
Apply a thin film of rust inhibitor (LPS-3) on lock face.
Repeat application on armature plate.

P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd

REV A1

04-11

Page 4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:b096f603-9aa1-11e4-0000-7c188db93ef5
Producer                        : GPL Ghostscript 9.10
Keywords                        : ()
Modify Date                     : 2015:01:09 13:26:24-08:00
Create Date                     : 2015:01:09 13:26:24-08:00
Creator Tool                    : PDFCreator Version 1.7.3
Document ID                     : uuid:b096f603-9aa1-11e4-0000-7c188db93ef5
Format                          : application/pdf
Title                           : INST-E1200
Creator                         : sdc-36
Description                     : ()
Author                          : sdc-36
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu