801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS E1200 SERIES MAGNETIC LOCK Interlocking Mounting Plate Quick Mount Interlocking Mounting Assembly Frame Mounting Screws Armature Outswing Electrical Instructions: Use properly fused U. L. Listed Power Supply Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur. Electrical Specifications: Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full wave bridge rectifier may be used. A significant drop will occur when using a full wave bridge rectifier. Power Consumption Any low voltage condition will cause erratic operation of the optional board sensor. Dual Voltage 12 or 24VDC .500mA@12VDC 250mA@24VDC DS Door Status Sensor SPDT, 500mA@30VDC LS Lock Status Sensor SPDT, 2A@30VDC When using a full wave bridge rectifier all access controls and/or release contacts must be located between the EMlock and rectifier to ensure quick release. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com 1. Inspect the frame header to determine if mounting accessories are required (refer to page 4). 2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the lock jamb side of the frame. 3. Mark and drill holes as indicated by the template. STEPS 2 & 3 4. Mount armature to door. STEEL WASHER 2X STEP 4 5/16-18 SOC HD SCREW WITH 3/16 (5MM) ALLEN HEX ARMATURE REINFORCEMENT TUBE 1-3/4“ HOLLOW METAL DOOR 5/8“ DRILL 1/2” DRILL SEXNUT RUBBER WASHER HOLLOW METAL DOOR From Sexnut side of door, drill exactly 1/2” hole thru one metal thickness only. From Armature side of door, drill 5/8” hole to insert reinforcement tube. Press in sexnut and reinforcement tube all the way and mount armature to door using hardware provided. 5. Install magnet onto the header with the magnetic stripes towards the door side of the stop. Assure that the magnet and armature line up properly, then tighten down ALL mounting screws. STEP 5 P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 2 6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the door. Tap with a soft hammer to ensure proper alignment and engagement. CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing STEP 6 7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock. SWITCH or ACCESS CONTROL 2 3 - NO A/C MAINS 4 C Lock Status Switch (Relay) + 1 + Power Supply 5 6 NC NO 7 8 C NC Door Position Sensor POWER SUPPLY - 12VDC or 24VDC R G B W ATTACH THE RED SIDE OF THE CONNECTOR HERE FOR A GREEN LED ENERGIZED & SECURE (RED=ENERGIZED & UNSECURE) G B R LED RED GRN ATTACH THE GREEN SIDE OF THE CONNECTOR HERE FOR A RED LED ENERGIZED AND UNSECURE (GREEN=ENERGIZED & SECURE) Voltage Jumper 12VDC 24VDC Door Position Sensor (Reed switch) NC COM RED (open with door closed) BLACK GREEN (closed with door closed) NO 8. Test operation. When all is operating properly, tighten all screws as shown. Install security pins and screws as shown. Install anti-tamper plugs over socket head screws using a soft hammer to avoid damage to the housing. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 3 MOUNTING ACCESSORIES: STOP FILLER PLATE EF02 Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D GLASS DOOR ARMATURE BRACKET E12U For use with Model E600 Series Field adjustable for glass thickness ANGLE BRACKET E12L Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D TOP JAMB MOUNTING BRACKET E12Z For use with Model E1200 Series ADJUSTABLE ANGLE BRACKET E12A For use with Model E1200 Series Supplied Mounting Hardware To maintain surface plating from corrosion: Do not touch the lock face with your hands. Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper). Apply a thin film of rust inhibitor (LPS-3) on lock face. Repeat application on armature plate. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:b096f603-9aa1-11e4-0000-7c188db93ef5 Producer : GPL Ghostscript 9.10 Keywords : () Modify Date : 2015:01:09 13:26:24-08:00 Create Date : 2015:01:09 13:26:24-08:00 Creator Tool : PDFCreator Version 1.7.3 Document ID : uuid:b096f603-9aa1-11e4-0000-7c188db93ef5 Format : application/pdf Title : INST-E1200 Creator : sdc-36 Description : () Author : sdc-36 Subject :EXIF Metadata provided by EXIF.tools