S6000 Spectra™ Exit Devices

Spectra Class - Specification Grade Exit Devices
for superior Architectural Style & Performance
The new mechanical SDC S6000 Spectra™ series panic and fire rated
exit devices are available in rim mount, mortise and surface vertical rod
configurations. Spectra Class mechanical exit devices are UL listed and
ANSI A156.3 Grade 1 compliant and comply with all national and state
building and fire life safety codes. The SDC Spectra series exit devices
have a modern look and quiet push pad operation.

Delayed Egress

Exit Alarm

Electric Frame Actuator

Electric Latch Retraction

•
•
•
•
•

Panic and fire exit hardware
ANSI/BHMA A156.3-2001 Grade 1 Compliant
CA Title 19 Compliant
Meets/Exceeds ADA requirements
UBC 97, Standard 7.2

SECURITY DOOR CONTROLS

Patents Pending
• Panic & Fire Exit Hardware
• ANSI/BHMA A156.3 Grade 1

sdcsecurity.com
service@sdcsecurity.com
Price & Installation

S6000 Spectra™ Exit Device Standard Series
Application

Device Spcifications

1-3/4”(44 mm) door thickness standard.
Specify thickness other than 1-3/4”.
• RHR or LHR hollow metal, wood and
mineral core doors.

Device Head Cover: Zinc alloy or stainless steel
Chassis: Steel, plated
Housing: Extruded aluminum
Push Bar Base: Extruded aluminum
Touch Plate: Stainless steel
Mounting: Machine screws standard. Sex bolts
optional. Order “SNB” for wood or
non-reinforced metal doors

End Cap: Zinc alloy
Hand: Non-handed
Dogging: Allen-type key furnished
Finish: 630 Stainless Steel
Special Finishes POA
Outside Trims: Order separately
UL Listed: ANSI/BHMA Grade1 Panic Exit
Hardware, 3-Hour Fire Exit Hardware.

Rim Mount Exit Devices
For use on single doors or pair of doors with mullion
• Minimum Stile Width : 4 1/2”(114 mm)
Latch Bolt: Stainless steel, 3/4"(19mm) throw

S6100

Latch: Deadlocking, Stainless steel,
5/8"(16mm) throw
Strike: Stainless steel

Surface Vetical Rod Exit Devices*
For use on single doors or pair of doors
• Minimum Stile Width : 3 1/2” (89 mm)
Top Latch: Stainless steel 37/64” (14.8mm)
Top Strike: Included
Bottom Latch: Stainless steel 37/64” (14.8mm)
Bottom Strike: Included

Latch Case Covers:
Steel, stainless steel or brass
Vertical Rods: Aluminum tube
Standard height: For 7’0” doors

*LBR Device - Less Bottom Rod
S6200 SVR
S6200-LBR SVR

Mortise Exit Device
For use on single doors or active leaf of double doors

Mortise Lock Specifications
S6300

Lock Case :
Steel plated 6 1/16” x 3 15/16” x 29/32”
(154mm x 100mm x 23mm)
Anti-friction Latchbolt : 3/4”(19mm) throw
Hand: Reversible without removing the lock
from the door

Auxiliary Deadlocking Bolt :
Non-handed, stainless steel
Faceplate:
Adjustable, 19/32” stainless steel or brass.
Strike : ANSI 4 7/8”

Mechanical Trim
EK
Eclipse

Trim

Options

Finish

• 1 rim cylinder required for 03,
mortise cylinder required for 08 function
• 1 mortise cylinder required for CD option
CD
Keyed dogging. Specify key cylinder
separately.
Not available with (F) fire exit device.
CYL-6KDQ 6 pin, 1.125" mortise cylinder, keyed
different, dull chrome
CYL-6KAQ 6 pin, 1.125” mortise cylinder, keyed
alike, dull chrome
RIM-CYL
5 pin, 1.125” mortise cylinder, keyed
different, dull chrome

Dummy Trim: EK02, GK02, SP02
Key Retracts Latchbolt: EK03, GK03, SP03
Key Locks/Unlocks Lever: EK08, GK08
No Cylinder Lever Always Active: EK14, GK14

SP
Saturn
GK
Galaxy

U 630 Dull Stainless Steel standard

Electric Trim
EKE03 Eclipse,
less cylinder

Features

GKE03 Galaxy
less cylinder

Trim

• Failsecure, field reversible to failsafe
• 4 ft. cable and connectors
• 12/24VDC @ 600/300 mA

EKE03 Eclipse style electric trim, less mortise cylinder
GKE03 Galaxy style electric trim, less mortise cylinder

Finish

Options

U 630 Dull Stainless Steel standard

LS Locked/unlocked status, SPDT 3 Amp contact

STRIKES (SCREWS INCLUDED)
RIM DEVICES USE

SURFACE / CONCEALED VERTICAL ROD DEVICES USE

Rim Strikes

Top Strikes

Bottom Strikes

ST1P

ST1F

ST2P

Standard
for
S6100P

Standard
for
S6100F

Standard top strike for
S6200P
Projection: 29/32” (23mm)

Projection:
13/16” (21mm)

Projection:
13/16” (21mm)

ST2F
Standard top strike for
S6200F
Projection: 1-1/8” (29mm)

(Floor Strikes)

Mortise: 2-1/4” (21mm)

Optional Threshold Strikes
ST28T
Optional floor strike for using threshold openings
Projection: 3/8” (9.5mm)

OPTIONAL DOUBLE DOOR STRIKE
ST2DF
Optional for pairs of doors
with rim mount device.
Projection: 1-15/16” (33mm)

REMOVABLE MULLION
KR90F
Standard Key Removable Mullion
For Panic Exit and Fire Exit Rim
Mount Devices.
Length: 8ft
Material: 2” 11 Gauge
Steel Tube
Finish: Primer gray

Optional Mullion Strike
ST1MP

For 6100P
Optional for mullion
application

ST1MF

For 6100F
Projection: 7/8” (22.5mm)

How to Specify S6000

Mechanical Trim

Model
Spectra Series Exit Device
S61 Rim mount
S62 Surface vertical rod
S63 Mortise

EK Eclipse

SP Saturn

Trim
Dummy Trim: EK02, GK02, SP02
Key Retracts Latchbolt: EK03, GK03, SP03
Key Locks/Unlocks Lever: EK08, GK08
No Cylinder Lever Always Active: EK14, GK14

ANSI Functions
01
02
03
08
14

GK Galaxy

Exit only, No Trim
Dummy pull or lever (opens when dogged)
Lever or pull, key latch retraction
Lever with key locks/unlocks lever
Lever trim always active

Panic or Fire Rated
P Panic Exit Device
F Fire Exit Device
P - Mechanical dogging STD;
(Add part # CD for optional key cylinder dogging)
F - Mechanical dogging not available

Finish
U 630 Dull Stainless Steel standard

Options
• 1 rim cylinder required for 03,
mortise cylinder required for 08 function
• 1 key cylinder required for CD option
CD
Keyed dogging. Specify key cylinder separately.
Not available with (F) fire exit device.
CYL-6KDQ 6 pin, 1.125" mortise cylinder, keyed different, dull chrome
CYL-6KAQ 6 pin, 1.125” mortise cylinder, keyed alike, dull chrome
RIM-CYL 5 pin, 1.125” mortise cylinder, keyed different, dull
chrome

Electric Trim

Handing

Features
• Failsecure, field reversible to failsafe
• 4 ft. cable and connectors		

RR Right hand reverse bevel, RHRB
LR Left hand reverse bevel, LHRB

• Audible tone
• 12/24VDC @ 600/300 mA

EKE03 Eclipse,
less cylinder

GKE03 Galaxy
less cylinder

Finish
Headcover, touchpad and endcap

U 630 Dull Stainless Steel standard

Trim
EKE03 Eclipse style electric trim, less cylinder
GKE03 Galaxy style electric trim, less cylinder
Finish

U 630 Dull Stainless Steel standard
C 605 Bright Brass
G 612 Dull Bronze
D 606 Dull Brass

Length
36 For 36" Door

42 For 42" Door

48 For 48" Door

P 625 Bright Chrome
Q 626 Dull Chrome

Options
LS Locked/unlocked status, SPDT 3 Amp contact

Options
R Request-To-Exit Output, SPDT
L Latch Status Output, SPDT

Ordering Example
Trim

Finish

Options

Spectra™ Series Options
How to Specify S6000 Electrical Options

A
B

Exit Alarm, 9V battery powered
Exit Alarm, 12-24V AC/DC input, 9V battery backup

ADA

• 100 dB alarm; visual and audible On/Off status:
Armed - green LED blinks every 4 seconds,
Alarm mode - red LED, Bypass - no LED
• Remote status output
• 15 or 60 second arming delay
• 2 modes: Continuous alarm with manual key reset; Automatic
re-arm 2 minutes after door closes with any manual key reset
before 2 minutes.
Options
• REX and latch status outputs
DE

Delayed egress exit device
Electrification of master exit device and wall mount controller
with keypad control and reset

KDE Keypad controller with redundant key switch capable of all keypad control features
DES For pair of doors, additional exit device equipped with delayed egress mechanism,
less controller. Must be ordered together with DE and device.
602RF 1 Amp power supply
• User PIN codes may be assigned to 1, 2 or all control functions.
Reset, sustained bypass and momentary bypass (REX
• Audible alarm voice release time, warning or safety message
• Visual display countdown, locked/unlocked, egress executed
• Selectable nuisance
Operations
NA

IBC, IFC, NFPA compliant, Field Selectable 15 to 30 second Exit Delay, 1 or 2 Nuisance Delay

NC

IBC, IFC, NFPA 101, NFPA 1-UFC, UBC, SBC compliant, Fixed 15 second Exit Delay, 0/1 Nuisance Delay, Calif. Building Code
OSHPD/Manual Power Up

ND

IBC, IFC, NFPA 101, NFPA 1-UFC, UBC, SBC compliant, Fixed 15 second Exit Delay, 0/1 Nuisance Delay

BC

BOCA National Building Code/City of Chicago Compliant, Fixed 15 second Exit Delay, 0 Nuisance Delay, Auto Reset 30 seconds

BD

BOCA National Building Code, Fixed 15 second Exit Delay, 0/1 Nuisance Delay, Auto Reset 30 seconds

Options
DEC-J

3 Gang Interior surface mount box for 101-DEC

SHD-J

Shroud for surface mount box DEC-J outdoor use

101-DE with
SHD-J

How to Specify S6000 Electrical Options cont.

E

Electric Latch Retraction

Operation: Momentary or maintained latch bolt and push
pad retraction, with simultaneous dogging.
Automatic re-triggering of latch retraction
Voltage:
24VDC @ 700 mA activation, 200 mA continuous
602RF 1 Amp power supply (1 EMC max)
632RF 2 Amp power supply (2 EMC max)
EMC 2-station sequencer required for automatic doors only.
Monitoring Available Latch status and REX output available

G Electric Dogging

When energized by optional built-in or remote switch manual,
depressing the pushpad, causes the pushpad and latch to remain
retracted (unlocked) providing push-pull door operation. When
de-energized or signaled by a fire alarm, the pushpad and latch are
released.
Voltage 170/100 mA @ 12/24VDC
Monitoring Available Latch status and REX output available

How to Specify S6000 Electrical Options cont.

H

Hitower Pro Frame Actuator Controlled Fire Exit Device

No wiring through door
No power transfer hinge or loop

GE03 Galaxy

Features include failsafe operation and unlocks by access control,
power loss or signal from fire command center. Door stays latched
even when unlocked. All wiring is maintained in the strike jamb.
Complies with national building and fire codes
Specify Handing and Voltage: 24VDC, 24VAC, 115VAC

G03 Galaxy

Status Output Options
L

Latch position status output, SPDT, 3 Amp

S

Latch & deadlocked status output, SPDT, 3 Amp

E03 Eclipse

EE03 Eclipse

Trim Options
EE03 Eclipse x Escutcheon

GE03

Galaxy x Escutcheon

NE03

Nova x Escutcheon

E03

G03

Galaxy

N03

Nova

M

•
•
•
•

Eclipse

Electric Mortise Exit Device
MF

Failsafe Electric Mortise Exit Device

MS

Failsecure Electric Mortise Exit Device

Field reversible failsecure/failsafe.
Remains latched when unlocked for fire door integrity
Failsafe (F) fire rated device for stairwell doors
Power loss or signal from fire command center releases failsafe device immediately

Voltage 600/300 mA @ 12/24VDC
Options
D

Door Position

N03 Nova
NE03 Nova

sdcsecurity.com service@sdcsecurity.com

Power Transfer Options
Power Transfer Hinge

Concealed Electric Power Transfer
PTM Heavy Duty Series
Electric Power Transfer Device
SDC’s heavy duty Electric Power Transfer Device provides a concealed and secure means of
transferring electric lock and exit device power
and signal wires from the frame to the door.
Completely concealed when the door is closed
the PTM Electric Power Transfer Device is
ideal for heavy traffic and applications requiring
higher security to inhibit tampering and abuse.

F

10B Listed for 3hr Fire Rated Door

DPS Contact
Optional

2 Conductor: Two (2) 18 Ga. wires, 5 Amp @ 12/24 V AC/DC
PTM-2AL

Aluminum Powder Coat, US28 equivalent

PTM-2BZ

Dark Brown Powder Coat, US10B equivalent

10 Conductor: Ten (10) 24 Ga. wires, 1 Amp @ 12/24V AC/DC
PTM-10AL

Aluminum Powder Coat, US28 equivalent

PTM-10BZ

Dark Brown Powder Coat, US10B equivalent

PT-5 Concealed Mortise Mount Power Transfer Loop
Frame mortised steel dust box with flexible steel loop and
chrome finish. Recommended for use with hollow metal
frames. UL Listed
Dimensions: 11.5”H x 1”W x 0.75”D (292 x 25.4 x 19mm)
10B Listed For
PT-5
3 Hrs Fire Rated Doors

PTH-4

Four conductor hinge, 1 Amp @ 12/24V per pair,
4.5" x 4.5" five knuckle standard weight
PTH-10 Ten conductor hinge, 1 Amp @ 12/24V per pair,
4.5" x 4.5" standard weight
Consult factory for 3 knuckle, or special sizes
Finish
All base material steel
Q 626 Dull Chrome (standard) H 613 Oil Rubbed Bronze
C 605 Bright Brass
P 625 Bright Chrome
Options
DPS Concealed Door Position Switch SPDT, 250mA @ 30VDC

Power Transfer Loops
18” (447mm) stainless steel armored flex conduit with small
plastic end caps or termination box. Recommended for use
with hollow metal and aluminum frames.
PT-2U

Application
Installed in the center hinge position of the door, PTH Power Transfer
Hinges provide the concealed wires required between the door and the
frame, for the purpose of powering and monitoring electric door hardware.
• Electric Lock Power and Control
• Door and Lock Status Signaling
• Request-to-Exit Signaling

Fire Rated Concealed Mortise Power Transfer

PT-2U With end caps
PT-3V With aluminum wire termination box

Features
• UL10B Listed for 3 Hr Fire Doors. If the hinge you are presently using
does not bear the F mark, it is not listed for use with fire doors.
• 500,000 cycles. 5 times UL test criteria
• Wire Replacement Warranty
• 5ft wire cable

PT-3V

DOUBLE DOOR APPLICATIONS

Rim Device and SVR Device combination - same
direction. Overlapping astragal is not required,
but coordinator required with a double door strike

Two Rim Devices on 2 independent active doors
with removable mullion.

SECURITY DOOR CONTROLS
© 2014 Security Door Controls

LIT-S6000 Spectra 04/14

M:\Marketing Files\In-House Pubs\Datasheets\Exit Devices\Spectra 6000 Exit Device.indd

Two Surface Vertical Rod (SVR) - same direction.
Overlapping astragal is not required.

www.sdcsecurity.com service@sdcsecurity.com
[t] 800.413.8783 805.494.0622
801 Avenida Acaso, Camarillo CA 93012 • PO Box 3670, Camarillo CA 93011-3670



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.5-c021 79.154911, 2013/10/29-11:47:16
Instance ID                     : uuid:04855c65-21d8-9f4d-80d8-c50fed171ffb
Original Document ID            : adobe:docid:indd:1d847293-1b3d-11e1-8d1a-aff70059993f
Document ID                     : xmp.id:9a920b87-507e-4364-ad31-12006225436c
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:7eebc130-98da-494a-80ba-55e291ad1faa
Derived From Document ID        : xmp.did:1ce8f2d0-0bdb-4b21-85f7-2c534c3b7a6c
Derived From Original Document ID: adobe:docid:indd:1d847293-1b3d-11e1-8d1a-aff70059993f
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Macintosh)
History Changed                 : /
History When                    : 2014:05:16 09:56:52-07:00
Create Date                     : 2014:05:16 09:56:51-07:00
Modify Date                     : 2014:05:16 09:57:49-07:00
Metadata Date                   : 2014:05:16 09:57:49-07:00
Creator Tool                    : Adobe InDesign CC (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CC (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu