SEIKAKU TECHNICAL GROUP WL-200R Wireless Microphone Receiver User Manual NF03650 WL 200R H P SHOW V1 3
SEIKAKU TECHNICAL GROUP LIMITED Wireless Microphone Receiver NF03650 WL 200R H P SHOW V1 3
Manual
A3 A4 A5 0.035KG/1 105G NH00149(3:8) WL-200R/H WL-200R/H SHOW_V1.3 -RS NF03650 SHOW SEIKAKU TECHNICAL GROUP LIMITED NO V1.2 V1.3 APR.16.2012 11/10/24 12/04/16 WIRELESS MICROPHONE SYSTEM User's Manual WL-200R/H/P NF03650-1.3 WIRELESS SYSTEM Technical Specifications SAFETY RELATED SYMBOLS Unplug this apparatus during lightning storms or when unused for long periods of time. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN External Connection The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even under the normal operating conditions. The external wiring connected to the output hazardous live terminals requires installation by an instructed person, or the use of readymade leads or cords. The symbol is used in the service documentation to indicate that specific component shall be only replaced by the component specified in that Documentation for safety reasons. Do not Remove any Cover Protective grounding terminal. The cover should be removed by the qualified personnel only. No user serviceable parts inside. There are maybe some areas with high voltages inside, to reduce the risk of electric shock, do not remove any cover if the power supply is connected. Alternating current /voltage. Hazardous live terminal . ON: Denotes the apparatus turns on. Fuse OFF: Denotes the apparatus turns off, because of using the single pole switch, be sure to unplug the AC power to prevent any electric shock before you proceed your service. To prevent a fire, make sure to use fuses with specified standard (current, voltage, type). Do not use a different fuse or short circuit the fuse holder. Before replacing the fuse, turn OFF the apparatus and disconnected the power source. WARNING: Describes precautions that should be observed to prevent the danger of injury or death to the user. Protective Grounding Disposing of this product should not be placed in municipal waste and should be separate collection. Make sure to connect the protective grounding to prevent any electric shock before turning ON the apparatus. Never cut off the internal or external protective grounding wire or disconnect the wiring of protective grounding terminal. CAUTION: Describes precautions that should be observed to prevent danger of the apparatus. Operating Conditions WARNING This apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on this apparatus. Power Supply Ensure the source voltage matches the voltage of the power supply before turning ON the apparatus. WIRELESS SYSTEM a blower or clean with rag etc. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Don't use solvents such as benzol, alcohol, or other fluids with very strong volatility and flammability for cleaning the apparatus body. Clean only with dry cloth. Do not use this apparatus near water. Install in accordance with the manufacture-r's instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not block any ventilation openings. Servicing Refer all servicing to qualified personnel. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so . No naked flame sources, such as lighted candles, should be placed on the apparatus. Servicing is required when the apparatus has been damaged in any way , such as power supply cord or plug is damaged , liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture , does not operate normally, or has been dropped. IMPORTANT SAFETY INSTRUCTIONS Read these instructions. Follow all instructions. Keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer. The mains plug is used as the disconnect device, the disconnect device shall remain readily operable. Power Cord and Plug Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. FCC Rules and Regulations SHOW wireless receivers are certified under FCC Rules part 15 and transmitters are certified under FCC Rules part 74.Licensing of SHOW equipment is the user's responsibility and licensability depends on the user's classification,application and frequency selected. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. Operating Instruction WL-200 consists of transmitter (microphone) and receiver. Automatically calibrate frequency to match up the frequencies of microphone and receiver Transmitter (microphone) functions description 1. Red LED, Orange LED and a push-button equipped at bottom 2. If red LED always lights up, it means that the transmitter (microphone) is muted; if the red LED blinks, it means that the battery is of low level. 3. If the orange LED always illuminates, it means that the battery is of high level. If the orange LED blinks, it means that the IR frequency calibration needs confirming. 4. Press and hold the push-button 2 seconds the push-button to power on the unit; press and hold the push-button 2 seconds to power off the unit. Press the MUTE button slightly, the volume will be muted. 5. Frequency calibration Align the bottom of the transmitter (microphone)to IR indicator of the receiver within distance of 20cm until the orange LED at bottom of the transmitter (microphone) begins to blink. Then press push-button at the bottom for confirm. The orange LED always illuminates, presenting frequency calibration ok. Receiver function description 1. Press the SET button to manually set CH1~CH16 with corresponding LED on front panel displaying 0~F. 2. Press the SCAN button to automatically calibrate the frequency. 3. Frequency calibration Press the Scan button to automatically calibrate the IR frequencies. The receiver will automatically search the available frequency and send the IR signal. The blinking LED means that it's searching the signal. The LED will not stop blinking until the signal is received. 4.Up to 6 channels are available for the WL-200 without interference to each other. The six frequencies are as follows: CH00,CH02,CH04,CHB,CH09,and CHD. NOTE: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules .These limits are designed to provide reasonable protection against harmful interference in a residential installation . This equipment generates, uses and can radiate radio frequency energy and , if not installed Cleaning When the apparatus needs a cleaning, you can blow off dust from the apparatus with WIRELESS SYSTEM CONTROL ELEMENTS WL-200P IR Receiving Section Dual Colour LED Power Switch/Mute Volume Control MINI 4P CONNECTOR This connector is used to connect the unit with the clip microphones, for example, HM-38 or HM-58 condenser microphones. D C Pin 1, GND Pin 2, Phantom power supply for Condenser microphone Pin 3, for Guitar, bass and keyboards Pin 4, for Dynamic or condenser microphone FREQUENCY TABLE Channel Frequency Channel Frequency Channel Frequency 00 175.125MHz 06 176.975MHz 182.025MHz 01 175.375MHz 07 177.925MHz 183.225MHz 02 175.775MHz 08 178.125MHz 184.525MHz 03 175.975MHz 09 178.925MHz 185.125MHz 04 176.175MHz 180.725MHz 05 176.525MHz 181.525MHz This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference and (2) this device must accept any interference received. including interference that may cause undesired operation. and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/ TV technician for help. INTRODUCTION Thanks for purchasing the SHOW wireless microphone system. The WL-200 is the delicately designed VHF, PLL synthesized system, with antenna for smart switching diversity control, the higher level RF signals maybe fed into the system for greater reliability and coverage, therefore, the risks of breakdown and interference are to be effectively reduced. The WL-200 features as follows: -Switching diversity control to receive the RF signal; -LED indication for RF, AF PEAK and POWER; -Output volume control; -Squelch control; -Soft touch painting for comfortable use; -Channel frequency adjusted manually -PLL synthesized design; -Consistent operating frequencies to comply with the EMC regulations; -16 channel frequency presets; WIRELESS SYSTEM CONTROL ELEMENTS CONTROL ELEMENTS WL-200R REAR PANEL FRONT PANEL AUDIO OUTPUT JACK This is a professional unbalanced output jack. VOL SWITCH It is used to adjust the volume . Squelch SWITCH ANT-A & ANT-B It is the flexible antenna. To get effective transmission, never cover the antenna with hand , clothes, etc during the operation, and always position the transmitter nearby the receiver. SELECT button Press the SET button to manually set CH1~CH16 with Display showing 0~F. SET/SCAN The SET button is used for selecting the desired frequency available and then press for confirm. Press the SCAN button to automatically calibrate the frequency. IR Transmitting Section AF-peak When this LED is illuminating, it means that the signal of the microphone is too strong. It is used to adjust the squelch level by using an adjusting bar which is placed in the microphone. XLR AUDIO OUTPUT This is a professional balanced XLR output connector. DC IN Connect 12V-15DC power supply to power on/off this unit. WL-200H Display This sexy and smart display will show exact Channel selected from 0~F, totally 16 channels. Diversity LED A & B These two LED will light up when the ANT-A & ANT-B are used. Power LED(dual colour LED) Power Switch/Mute IR Receiving Section
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2012:05:02 13:37:57+08:00 Modify Date : 2012:05:02 13:37:57+08:00 Page Count : 7 Creation Date : 2012:05:02 05:37:57Z Mod Date : 2012:05:02 05:37:57Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : hongjundeng Metadata Date : 2012:05:02 05:37:57Z Creator : hongjundeng Title : NF03650(WL-200R-H-P SHOW_V1.3...EXIF Metadata provided by EXIF.tools