SM Instruments S205W Wireless Portable Sound Camera User Manual
SM Instruments Inc. Wireless Portable Sound Camera
User Manual
SeeSV-S205W User's Manual SeeSV-S205 User's Manual Rev: 1.4.0 Contents Contents........................................................................................................................................................................................................... 1 Introduction of System ............................................................................................................................................................................. 3 2.1 Components of System ................................................................................................................................................................. 3 Hardware Installation................................................................................................................................................................................. 4 3.1 Hardware Installation ..................................................................................................................................................................... 4 3.2 Status of Sound Camera Lamp.................................................................................................................................................. 7 Software Installation .................................................................................................................................................................................. 8 4.1 Sound Camera Software Installation ...................................................................................................................................... 8 4.2 Sound Camera Software Activation ..................................................................................................................................... 13 4.3 IP Config ............................................................................................................................................................................................ 15 Software Functions .................................................................................................................................................................................. 17 5.1 Software Mode ............................................................................................................................................................................... 17 5.2 Control Buttons .............................................................................................................................................................................. 18 5.3 Sound Camera Image ................................................................................................................................................................. 18 5.4 Image Threshold ............................................................................................................................................................................ 19 5.5 Image Range ................................................................................................................................................................................... 19 5.6 Image Average ............................................................................................................................................................................... 19 5.7 Signal Graphs .................................................................................................................................................................................. 20 5.7.1 Time Signal of Microphone ....................................................................................................................................... 20 5.7.2 Power Spectrum of Microphone ............................................................................................................................. 21 5.7.3 Level Trend of Beampower......................................................................................................................................... 21 5.7.4 1/3 Octave Level of Microphone ............................................................................................................................ 21 5.8 Band Pass Filter .............................................................................................................................................................................. 22 5.9 Graph Selector ................................................................................................................................................................................ 22 5.10 Device Status Lamp .................................................................................................................................................................. 22 5.11 Setup ............................................................................................................................................................................................... 22 5.11.1 Data Folder ................................................................................................................................................................... 23 5.11.2 Open Data Folder ...................................................................................................................................................... 23 5.11.3 Prefix of Filename ...................................................................................................................................................... 23 5.11.4 Record Type .................................................................................................................................................................. 23 5.11.5 Trigger Level ................................................................................................................................................................. 24 5.11.6 Duration ......................................................................................................................................................................... 24 5.11.7 Product Type ................................................................................................................................................................ 25 Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.8 Mic Gain ......................................................................................................................................................................... 25 5.11.9 Mic Channel ................................................................................................................................................................. 25 5.11.10 Max/Min Level............................................................................................................................................................. 25 5.11.11 Overlay Mode .............................................................................................................................................................. 26 5.11.12 Transparency ................................................................................................................................................................ 26 5.11.13 Mirror Mode................................................................................................................................................................. 26 5.11.14 Image Calibration…………………………………………………………………………………………………………………...29 5.11.15 Recording Advanced Setup……………………………………………………………………………………………………29 Software shortcut keys .......................................................................................................................................................................... 28 Maintenance and Troubleshooting .................................................................................................................................................. 29 7.1 Sound Camera Firmware Update .......................................................................................................................................... 29 7.1.1 7.2 Modify the focus of sound camera ……………………………………………………………………………………………………32 7.2.1 7.3 How to update Sound Camera Firmware ........................................................................................................... 29 How to modify the focus of sound camera ……………………………………………………………………………..32 Modify the position of overlay image…………………………………………………………………………………………………33 7.3.1 How to modify the position of overlay image ………………………………………………………………………33 Specifications .............................................................................................................................................................................................. 34 Caution ………………………………………………………………………………………………………………………………………………………..35 Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual 2.1 Rev: 1.4.0 Introduction of System Components of System Item Description Portable sound camera. AC/DC Power Adaptor LEMO to LEMO Cable.(10m) RJ45 LAN Cable.(1m) Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual 3.1 Rev: 1.4.0 Hardware Installation Hardware Installation Status Description Open the outer box. Open the inner box. SeeSV-S205W Manual. SeeSV-S205W Quick Manual. SeeSV-S205W Install CD Take the cables out. Doc. Type: User Manual LEMO to LEMO cable. RJ45 LAN cable POE Controller SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Take out the sound camera. Main components of the system are shown here. Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Power switch. The power is turned on, press the button for 3 seconds. Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual 3.2 Rev: 1.4.0 Status of Sound Camera Lamp Status Description Not powered. Initializing (orange). Sound camera is ready to use (green). Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual 4.1 Rev: 1.4.0 Software Installation Sound Camera Software Installation Item Description Run “Setup.exe”. Confirm destination directory and click “Next>>”. Read Product Notifications and click “Next>>”. Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Read license agreement. Check “I accept the above 2 License Agreements” and click “Next>>”. Confirm items for installing and click “Next>>”. Doc. Type: User Manual SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Installation is proceeding. Installation is complete. Click “Next>>”. The NI vision run-time engine should be activated. Connect PC to the internet and select "Automatically activate through a secure Internet connection". Click “Next>>”. Doc. Type: User Manual 10 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Input the serial number of NI Vision Run-Time Engine in both boxes. For members of “www.ni.com”, select “User Profile Login”. In this, “Continue without a User Profile" is screenshot shown. Input end user information. Doc. Type: User Manual 11 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Activation is in process. The NI vision run-time engine is successfully activated. Click “Finish”. If this is the first time to install the software, you will be requested to restart the PC. Click “Restart”. Software installation is complete. Doc. Type: User Manual 12 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 4.2 Rev: 1.4.0 Sound Camera Software Activation Item Description If the software is being installed for the first time, the software license confirmation window will appear. Click the “Activate SeeSV”. Click the “Activate SeeSV Online”. Input to License ID & password in text box. Doc. Type: User Manual 13 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Software is successfully activated and click the “Continue”. The sound camera is ready for use. Doc. Type: User Manual 14 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 4.3 Rev: 1.4.0 IP Config Item Description 1. Open Network Connections by clicking the Start button Doc. Type: User Manual 15 , and then clicking Control Panel. 2. Click the Network and sharing Center. 3. Click “Change adapter settings”. 4. Double Click “Wire connection”. SM Instruments Co., Ltd. SeeSV-S205 User's Manual 5. Rev: 1.4.0 Click the “Internet Protocol Version 4(TCP/IPv4)”, and then click “Properties”. 6. Click the “Use the following DNS server addresses”, and then, write in the boxes. “IP address: 192. 168. 0. 102” “Subnet mask: 255. 255. 255. 0” “Default gateway: 192. 168. 0. 1” Click “OK”. Tip: Except IP address last number 6, 10, and 90 ※ Can’t use more than 2 devices at the same time. 7. Check connection to main body and pc. Turn on power. Wait until lamp of the main body turns >> green. 8. >> Doc. Type: User Manual Run SeeSV software. Check lamp to DAQ and Camera. 16 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Software Functions Run the software and following screen will appear. Measurement Beamforming Controller Controller Image Display Setting Preset Signal Graphs Device Status 5.1 Software Mode Select software mode using this button (Record or Replay). Selected mode can be confirmed by the color and icon of the button.. Button status Description Record mode. Replay mode. Doc. Type: User Manual 17 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 5.2 Rev: 1.4.0 Control Buttons Functions of each button are as follows. Button Function Play recorded data. Stop (Record/Replay). Record data. Restore data file. Convert data to movie file and save. Save image as PNG (graphic) format. Open the documents such as Application Guide, User’s Manual, and Quick start Manual. 5.3 Sound Camera Image Display the camera, beam power overlaid image and measurement information. Doc. Type: User Manual 18 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 5.4 Rev: 1.4.0 Image Threshold Adjust the threshold level of the beam power which is displayed on the display window. Beam power below the threshold level will not be shown. If the current beam power is less than the threshold level, it will not be shown. When the threshold level is higher than minimum value of the image range, contour image will only include the values between maximum values of the image range and the threshold level. 5.5 Image Range Adjust displayed range of the beam power level. [“Max beam power” – “Image Range”] will be presented. Value Meaning Manual Scale Manually select Max/Min level. Max/Min level is located in Advanced Setting. 0.01~10 Display beam power level between Max and (Max - adjusted value). If select 3, displayed level will be [“Max”~ “Max-3”]. Auto Scale 5.6 Adjust displayed level of beam power automatically. Image Average Adjust averaging of the beam power image. Adjust None Exp.1~Exp.49 Linear Description No averaging. Exponential average of adjusted number of images. Linear image average. Refresh image average. Doc. Type: User Manual 19 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 5.7 Rev: 1.4.0 Signal Graphs Display time signal of the microphone, power spectrum, 1/3 octave and trend of beam power level. Use the Graph Selector control outlined in red to select the type of graph. 5.7.1 Time Signal of Microphone Displays time history signal of the microphone selected. Mode Description Record Displays instantaneous signal of the microphone on real –time (0.04 sec). Replay Displays whole range of recorded data of the microphone. Use the mouse or cursor key to adjust the section of replay section between two red-dotted cursors. The image will be displayed according to the position of the first cursor. Doc. Type: User Manual 20 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.7.2 Power Spectrum of Microphone Displays power spectrum of the microphone selected. Adjust band pass filter using the two cursors. Adjusted range will be highlighted. Frequency range of the filter can be adjusted using the "Band Pass Filter" controls. 5.7.3 Level Trend of Beampower Displays of the beam power level trend for 10 sec. The red-dotted line is the threshold, and orange-dotted line is the trigger level when the record mode is "trigger". 5.7.4 1/3 Octave Level of Microphone Displays of the 1/3 octave band level of the microphone signal. Doc. Type: User Manual 21 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 5.8 Rev: 1.4.0 Band Pass Filter Adjusts the band pass filter of the beampower. 5.9 Graph Selector Selects graph to display. 5.10 Device Status Lamp Displays the status of the connection of the sound camera. Color Description Not connected. Connected. 5.11 Setup Displays or hides items for settings. Status Description Threshold, Image Range & average, Band Pass Filter, Graphs, & Basic Display Icons Path, Record, Sound Camera, Display Configuration, and Firmware Update setting Image Calibration, Replay & Record Advanced setting, and DAQ status setting Doc. Type: User Manual 22 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.1 Data Folder Defines path of the data file. This path will be the default setting for the following: Save data Open data file Save screenshot Convert/save movie 5.11.2 Open Data Folder Opens the data folder. 5.11.3 Prefix of Filename Sets prefix of filename to be saved. If the prefix is “SeeSV-S20x”, the filename will be as following. “SeeSV-S20x_[yyyymmdd][HHMMSS].tdms” 5.11.4 Record Type Sets record type. Normal: Continuously saves data when the "Record" and "Stop" buttons are pressed. Trigger: After the "Record" button is pressed, records data when it exceeds the trigger level of the beam power Doc. Type: User Manual 23 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.5 Trigger Level Sets trigger level. 5.11.6 Duration Sets the recording time in seconds when the trigger is activated. Duration Pre-trigger (Second, buffer Trigger is (5 frames=0.2s, occurred. adjustable) Trigger Level Thres hold 5.11.7 Mic. Channels Sets number of Microphone channels One All Doc. Type: User Manual 24 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.7 Product Type Select model of sound camera being used. SeeSV-S205 SeeSV-S200 5.11.8 Mic Gain Set the gain of the microphone. The range of gain is -10dB/0dB/+10dB/+20dB/+30dB. 5.11.9 Mic Channel Select the microphone to be measured and displayed. 5.11.10 Distance (m) Sets distance between a sound camera and noise source. 5.11.11 Max/Min Level When the Display Range is set to User Scale, adjust Max Level and Min Level to be displayed. Doc. Type: User Manual 25 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.12 Overlay Mode Select color set of beam power. Mode Description Rainbow Gray Temperature Binary Gradient 5.11.13 Transparency Set transparency of displayed beam power. 0 (opaque) 1 (transparent) Value Description 0.1 0.9 5.11.14 Mirror Mode Show mirror image. Status Description ON OFF Doc. Type: User Manual 26 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.14 Image Calibration Show automatic image calibration. Status Description Before After 5.11. 15 Replay Advanced Setup Selects replay advanced setup. Audio Filter: Amplifying the volume from noise source when a user coverts t은 file to avi file. Delete text Avi.: Removing text data on an avi file. Doc. Type: User Manual 27 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 5.11.15 Recording Advanced Setup Sets Recording Time up to 180 seconds. 5.11.16 DAQ Status Shows a sound camera device information. Software shortcut keys Shortcut Function Ctrl+1 Display time history signal of the microphone. Ctrl+2 Display power spectrum of the microphone. Ctrl+3 Display trend graph of beam power level. Ctrl+4 Display 1/3 octave band graph of the microphone. Left Cursor Move first cursor to left at time signal graph of review mode Right Cursor Move first cursor to right at time signal graph of review mode Up Cursor Increase image threshold. Down Cursor Decrease image threshold. Doc. Type: User Manual 28 SM Instruments Co., Ltd. SeeSV-S205 User's Manual 7.1 Rev: 1.4.0 Maintenance and Troubleshooting Sound Camera Firmware Update 7.1.1 How to update Sound Camera Firmware Item Description Run SeeSV software and then click the button. Click the button “Firmware”. Click the button “Open”. Doc. Type: User Manual 29 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Select the firmware file which is distributed with the installation file. (*.scfw file) Click “Update” to start. Before proceeding and during the update. - Confirm the connection of sound camera. - Keep power on. - Keep connection of sound camera connected. Update can take several minutes. Wait for notification popup before proceeding. Doc. Type: User Manual 30 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Update completed. Run sound camera software to ensure update was successful. 7.2 Modify the focus of sound camera 7.2.1 How to modify the focus of sound camera Item Description Previous image to be improved: Abnormal focus image. After image improvement: Normal focus image. Doc. Type: User Manual 31 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Camera lens hardware part. 1. CAM Status LED Indicator 2. Lens Fixed Screw 3. Lens Camera focus control method: Turn to the left and right lens fixed focus. ※ Cause: If you turn to the right to force the lens may be damaged. 7.3 Modify the position of overlay image 7.3.1 How to modify the position of overlay image Item Description Previous image to be improved: Abnormal focus image. (Before using Image calibration) Doc. Type: User Manual 32 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 After image improvement: Normal focus image. (After using Image Calibration) Developer's menu is displayed by click the "ctrl + ]" key. And Click “x(m) or y(m)” button manually. Or you can control image calibration by “Auto Cal”. Overlay image control method: 1. Click the Display control icon “Auto Cal”. 2. Click center to overlay image. Drag and drop position to noise source. Doc. Type: User Manual 33 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0 Specifications Microphone Array Microphone Type Digital MEMS Microphone Number of Microphones 30 Microphone Sensitivity 70 mV/Pa Array Diameter 350 mm Frequency Range (Full) 350 to 12000 Hz Frequency Range (Recommended) 2000 to 10000 Hz Measurement Distance 0.2 to 5.0 m (Recommended) Weight 2.4kg Data Acquisition and Processing Sampling Rate 25.6k S/s/ch Image Update Rate 25 FPS Imaging Algorithm Beamforming (delay and sum) Image Ranging Automatic/Manual Environmental Condition Operation Temperature -20 to 50°C Humidity 10 to 85 % RH Doc. Type: User Manual 34 SM Instruments Co., Ltd. SeeSV-S205 User's Manual Rev: 1.4.0This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications to the equipment not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment. This appliance and its antenna must not be co-located or operation in conjunction with any other antenna or transmitter. A minimum separation distance of 20 ㎝ must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. • The product can be damaged by external shock. • Please do not disassemble the product. • Please check rated voltage when you charge the product. (for wireless camera model only) • Please keep away from fire and liquid. Insuring Indoor Use in 5.15-5.25 GHz Band (15.407 (ii)) FCC 15.407(ii) states: "For an indoor access point operating in the band 5.15-5.25 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W provided the maximum antenna gain does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 17 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi" Doc. Type: User Manual 35 SM Instruments Co., Ltd.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : ko-KR Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Format : application/pdf Creator : CHLEE Title : SeeSV-S205 사용자 설명서 Create Date : 2015:10:23 09:16:40+09:00 Creator Tool : Microsoft® Word 2010 Modify Date : 2016:03:24 11:21:32+09:00 Metadata Date : 2016:03:24 11:21:32+09:00 Producer : Microsoft® Word 2010 Document ID : uuid:9932462b-284c-4c3a-ad80-c9a8fe2dc031 Instance ID : uuid:b1308a7f-2fba-4a21-accd-dbd91653170e Page Count : 36 Author : CHLEEEXIF Metadata provided by EXIF.tools