User Manual_20150825_v1 - W6U2500T_User Manual
SC-MRU2500T User Manual SOLiD, Inc. 10,9th Floor, SOLiD Space220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 393-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 Confidential & Proprietary 1/26 SC-DAS REVISION HISTORY Version Issue Date V 1.0 April. 13, 2015 No. of Pages Initials Details of Revision Changes Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.kr or send email at sjkim@solid.co.kr This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 2/26 SC-DAS Contents Section1 Safety & Certification Notice ....................................................................... 5 Section2 System Overview ....................................................................................... 8 2.1 General overview ............................................................................................ 9 2.2 ROU Dimension ............................................................................................. 12 Section3 3.1 ROU Installation ....................................................................................... 13 ROU Installation ............................................................................................ 14 3.1.1 ROU Enclosure installation ....................................................................... 14 3.1.2 ROU Power Cabling ................................................................................. 21 3.1.3 Optical Cabling ........................................................................................ 22 3.1.4 GND Terminal Connection .............................................................................. 22 3.1.5 Coaxial cable and Antenna Connection ..................................................... 23 Section4 ROU Specification..................................................................................... 24 4.1 Specifications ................................................................................................ 25 4.1.1 Optical Specification................................................................................ 25 4.1.2 Environment Specification ....................................................................... 25 4.1.3 DL RF Specification .................................................................................. 25 4.1.4 UL RF Specification .................................................................................. 26 Confidential & Proprietary 3/26 SC-DAS Figures Figure 2.1 – Remote Unit dimension ................................................................. 12 Figure 3.1 – Wall mount dimensions for the ROU .............................................. 14 Figure 3.2 – ROU installation procedure side by side ......................................... 15 Figure 3.3 – ROU installation diagram side by side ............................................ 16 Figure 3.4 – ROU installation procedure for stacked mounting .......................... 16 Figure 3.5 – ROU installation diagram for stacked mounting.............................. 17 Figure 3.6 – ROU installation procedure for vertical rack ................................... 18 Figure 3.7 – ROU installation diagram for vertical rack ...................................... 19 Figure 3.8 – ROU installation procedure for horizontal rack............................... 20 Figure 3.9 – ROU installation diagram for horizontal rack .................................. 20 Figure 3.10 – ROU Power Port view.................................................................. 21 Figure 3.11 – ROU optical Port view .................................................................. 22 Figure 3.12 – ROU GND Port view ..................................................................... 23 Confidential & Proprietary 4/26 SC-DAS Section1 Safety & Certification Notice Confidential & Proprietary 5/26 SC-DAS “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” -The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. - Obey all general and regional safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. - Use this unit only for the purpose specified by the manufacturer. Do not modify or fit any spare parts that are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. Actual separation distance is determined upon gain of antenna used. We recommned that the maximum antenna gain should not be exeed 17 dBi for 2496~2690 MHz. RF exposure compliance should be addressed at the time of licensing. - Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐only restrictions is prohibited - Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation. - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors. - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure. - Allow sufficient fiber length to permit routing without severe bends. - A readyily accessible disconnect device shall be incorporated external to the equipment. - The following notice: "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band Confidential & Proprietary 6/26 SC-DAS users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device." - The power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device. - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device. - The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. - Round terminals located on the side of a 12 AWG or more wires Using permanently connected to earth.(green/yellow color) - This is only to be used with BTS devices supporting licensed cellular operations - Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and - Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location. - Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24,27 and 90 UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040 - Repeater warning label message should include Confidential & Proprietary 7/26 SC-DAS Section2 Confidential & Proprietary System Overview 8/26 SC-DAS 2.1 General overview 2.2 ROU Dimesion 2.1 General overview SC-DAS platform is a coverage system for in-building services delivering seamless, high quality voice and data As a distributed antenna system, it provides analog and digital phone services in multiple Confidential & Proprietary 9/26 SC-DAS bands through one antenna. The system covers public and private venues such as: Shopping malls Hotels Campus areas Airports Clinics Subways Multi-use stadiums, convention centers, etc. The system enhances in-building radio environments that lack signal quality by improving the RSSI and Ec/Io. By providing communication services throughout the building, the system enables users to make a calls anywhere in the coverage area. The system uses both analog (AMPS) and digital (TDMA, CDMA,WCDMA and LTE) methods. The SC-DAS system supports communication standards and public interface protocols in worldwide use. Frequencies: VHF,UHF, 700MHz, 800MHz,850MHz 900MHz,1900MHz,2100MHz, 2500MHz etc. Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc. Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging,LTE, etc. SC-DAS comprises frequency specific modules. Coverage for a specific frequency band is accomplished by inserting a corresponding frequency module into each unit. Because it delivers multiple signals with one strand of single mode fiber, the system, requires no additional hardware modifications whenever a new frequency is added. The system is featured with the following: Flexibiltiy & Scalabiltiy Supports fiber-optic ports up to 32 or 60(using OEU) Connects multiple-buildings (campus) as one DAS Modular structures Modular frequency upgrade Plug-in type modules Multi-Band, Single operator Supports multiple services from one WSP Support multi-operator in a band(Max. 2 operator) Low OPEX / CAPEX Confidential & Proprietary 10/26 SC-DAS Compact design Upgradable design Easy installation and maintenance Adopts auto ID scheme The SC-DAS platform will serve two primary segments; first as a carrier deployed coverage enhancement product for their specific frequencies and second as a low cost, public safety / single carrier product. Confidential & Proprietary 11/26 SC-DAS 2.2 ROU Dimension Figure 2.1 – Remote Unit dimension ITEM SPECIFICATION REMARK Size(Width, Height, Depth) 200 x 300 x 140mm Including Bracket Weight Power Consumption Operating Temperature Operating Humidity 6.8kg 52W -10 to +50°C 0 to 90%, non-condensing Fully loaded Fully loaded Ambient Temperature Confidential & Proprietary 12/26 SC-DAS Section3 ROU Installation This chapter describes how to install each unit and corresponding fiber cables, along with power cabling method. In detail, the chapter describes how to install shelves or enclosures of each unit, Power Cabling method , Optic Cabling and RF Interface. Furthermore, by showing power consumption of modules installed in each unit, a the Power Cabling budget is easily determined. Last, it describes the quantity of components of modules to be installed in each unit along with an expansion method. Confidential & Proprietary 13/26 SC-DAS 3.1 ROU Installation 3.1.1 ROU Enclosure installation The ROU enclosure has two options. One meets NEMA4 standard and the other is not waterproof or dirtproof. The ROU can be mounted on a Wall easily. Rack mounting is also possibleusing special frame. There are 3 different types and they will be explained later in this chapter. The ROU consists of anMRU and anARU. Their dimensions are thesame. The following shows the dimension of the mounting holes for the Wall Mount Bracket. Figure 3.1 – Wall mount dimensions for the ROU ROU Wall Mount Installation There are two way to install the ROU on the wall. One is to install ROUs on the wall side by side, the other is stack the ARU above the MRU. Type1 : Side by Side installation Install M8 mounting Screws roughly half way in, insert the wall mount bracket over the 2 screws and secure it with the last 2 screws. For convenience, the Wall Mount Bracket has mounting holes to let you easily mount an enclosure. Screw the M6 Wrench Bolts by half at each side of the Heatsink enclosure. Confidential & Proprietary 14/26 SC-DAS Figure 3.2 – ROU installation procedure side by side Place the enclosure with the M6 Bolt on the mounting groove and mount the M6 Wrench Bolts into the remaining mounting holes. In this case, you will use 4 M6 Wrench Bolts. Confidential & Proprietary 15/26 SC-DAS Figure 3.3 – ROU installation diagram side by side For connecting cables between MRU and ARU easily, the MRU should install on left side of ARU. Type2 : stacked installation If space prohibits the MRU and ARU from being mounted side by side, the units can be installed in a stacked configuration. Stacking the unit requires a special baracket for stacked installation First, install the MRU on the wall , then install the bracket for stacked installation on the MRU. Finally install the ARU on the bracket. Completed installation diagram is as follows Figure 3.4 – ROU installation procedure for stacked mounting Confidential & Proprietary 16/26 SC-DAS The following shows dimension of the mounting point for the stacked bracket. Figure 3.5 – ROU installation diagram for stacked mounting Confidential & Proprietary 17/26 SC-DAS ROU Rack Mount Installation There are two ways to install rack mount. One is to install ROUs on the rack vertically: the other is to install ROUs on the rack horizontally Type1 : Vertical installation on the rack For vertcal installation, a vertical bracket is needed. First, install bracket for vertical installation on the rack Second, mount MRU on the left side of the installed bracket Third, mount ARU on the right side of the installed bracket Completed installation diagram is as follows Figure 3.6 – ROU installation procedure for vertical rack The following shows dimension of the mounting Confidential & Proprietary point for vertical installation 18/26 SC-DAS Figure 3.7 – ROU installation diagram for vertical rack Type2 : Horizontal installation on the rack For Horizontal installation, horizontal bracket is needed. Unlike vertical installation, the MRU is mounted on the right of the installed bracket first and then ARU is installed to the left of MRU First, install bracket for horizontal installation on the rack Second, open the front cover of horizontal bracket Third, mount MRU on the right side of the installed bracket Fourth, mount ARU on the left side of the installed bracket Finally, close the front cover of horizontal bracket Completed installation diagram is as follows Confidential & Proprietary 19/26 SC-DAS Figure 3.8 – ROU installation procedure for horizontal rack The following shows dimensions of the mounting point for horizontal installation Figure 3.9 – ROU installation diagram for horizontal rack Confidential & Proprietary 20/26 SC-DAS 3.1.2 ROU Power Cabling The ROU supports both of DC-48V and AC120V input power. The type of input power for the ROU is already determined at the factory. The ROU is shipped with the correct power cable in the package box. See the UL name plate of the ROU to determine the input power type of the ROU or see the power connector in the below picture. You should order the type of input power as your application. (a)AC/DC (b)DC/DC Figure 3.10 – ROU Power Port view Check if your power cord connector is the same as one seen in the table above. The ROU does not have power switch to power on/off. Power supply is on when cord is plugged into the AC source. Confidential & Proprietary 21/26 SC-DAS 3.1.3 Optical Cabling The MRU makes the optical-RF conversion of TX signals from upper the ODU and OEU as well as the RF- optical conversion of RX signals. The MRU has one optical module in it. As WDM is used in the R_OPT module, two separate wavelengths (TX:1310nm, RX:1550nm) can be sent/received with one fiber strand at the same time. The MRU has SC/APC connectors. To prevent the fiber interface from being marred with dirt, it should be covered with a cap when not installed. Fiber connectors should be cleaned alcohocol to remove dirt before installation . Figure 3.11 – ROU optical Port view Only the MRU has optical port; there is no optical port on the ARU 3.1.4 GND Terminal Connection TheROU has one GND terminal port on bottom side, as shown below Confidential & Proprietary 22/26 SC-DAS Figure 3.12 – ROU GND Port view Take off the GND terminal port from the enclosure and connect to the ground cable. Then reconnect it to the enclosure The opposite end of the ground cable should connect to the communication GND of building The ground lug is designed meeting the SQ5.5 standard 3.1.5 Coaxial cable and Antenna Connection The coaxial cables which are connected to DAS connect to antenna port of the ROU. Before connection, check the VSWR of the coaxial cable using a SiteMaster to verify whether it is within tolerance. The Return loss should be better than 15dB or VSWR should be below 1.5: 1. Make sure the antenna connector is tightened properly and free of any dirt or insects. The antenna connected to the ROU is only for inbuilding use. Only the MRU has an antenna port. The ARU transmits its signal through RF cable connected to both the MRU and ARU Confidential & Proprietary 23/26 SC-DAS Section4 ROU Specification Confidential & Proprietary 24/26 SC-DAS 4.1 Specifications 4.1.1 Optical Specification Unit Name Connector SC_OEU_EWDM Remark RF SMA FEMALE (2-HOLE) / 50ohm Analog Optic SC / APC (STEP FERRULE) Power/Signal SMAW200-12C 12PIN MALE Laser Diode 1550nm(Coaxial Type) Photo Diode 1310nm Optic Loss 1dBo~ 5dBo 4.1.2 Environment Specification Item Specification Remarks Operating temperature range -10ºC ~ +50ºC Operation humidity 5% to 90% (non-condensing) Cooling Passive (natural convection) BIU/OEU : DC -48V(-42~-56)AC(ROU) , Power supply ROU : AC 90~264V Weight 6.6kg Power consumption 52W Degree of protection NEMA4 or Non-nema Dimension(H x D x W) 300*140*200mm 4.1.3 DL RF Specification Item Gain(dB) Bandwidth(MHz) output power(dBm) 2500T LB 48 67.6 +28 2497.8~2565.4 MHz 2500T UB 48 67.6 +28 2619.8~2687.4 MHz Confidential & Proprietary 25/26 Frequency range SC-DAS 4.1.4 UL RF Specification Item Gain(dB) Bandwidth(MHz) output power(dBm) 2500T LB 30 67.6 -20 2497.8~2565.4 MHz 2500T UB 30 67.6 -20 2619.8~2687.4 MHz Confidential & Proprietary 26/26 Frequency range SC-DAS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 26 Language : ko-KR Tagged PDF : Yes Title : MB DAS Author : 한경은 Creator : Microsoft® Office Word 2007 Create Date : 2015:08:24 16:38:02+09:00 Modify Date : 2015:08:24 16:38:02+09:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools