SOLiD 700P800P Multiple-Enclosure Booster System User Manual PS Manual SC MRU700PS800PS AC
SOLiD, Inc. Multiple-Enclosure Booster System PS Manual SC MRU700PS800PS AC
SOLiD >
Contents
- 1. Users Manual_Rev1_part 1
- 2. Users Manual_Rev1_part 2
- 3. Users Manual_Rev1_part 3
- 4. Users Manual part1
Users Manual_Rev1_part 1
SC‐DAS Installation and Operation Manual Document Reference: Version: V5.0 Document Status: Release 5 Issue Date: Feb. 13, 2013 Author: Kyung Eun Han Department: R&D Division Team 3 Authorizing Manager: Young shin Yeo Confidential & Proprietary 1/117 SC‐DAS REVISION HISTORY No. of Pages Version Issue Date Initials Details of Revision Changes V 1.0 April. 11, 2011 V 2.0 Dec. 08,2011 Add Sprint band V 3.0 Jan. 06,2012 Add Sprint band V 4.0 Jan. 07,2013 Add VzW (MRU MIMO) band V 5.0 Feb. 13,2013 Add PS (MRU) band Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD, Inc. website at www.solid.co.kr or send email at sjkim@solid.co.kr This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 2/117 SC‐DAS Contents Section1 Safety & Certification Notice....................................................................... 12 Section2 System Overview ....................................................................................... 15 2.1 General overview ............................................................................................ 16 2.2 System overview............................................................................................. 18 Section3 3.1 System Specifications ................................................................................ 21 System specifications ...................................................................................... 22 3.1.1 Physical Specifications .............................................................................. 22 3.1.2 Optical wavelength and Laser power......................................................... 23 3.1.3 Environmental specifications .................................................................... 23 3.1.4 Available Frequency Bands ........................................................................ 23 3.1.5 Band Specifications ................................................................................... 24 Section4 System Configuration and Functions ........................................................... 25 4.1 BIU (BTS Interface Unit) .................................................................................. 26 4.1.1 BIU Specifications .................................................................................................... 26 4.1.2 BIU block diagram ................................................................................................... 27 4.1.3 BIU assemblies ........................................................................................................ 27 4.1.4 Sub Assembly Description ........................................................................................ 28 4.1.5 BIU front/rear panel overview .................................................................................. 32 4.2 ODU (Optic distribution Unit) .......................................................................... 35 4.2.1 ODU specifications................................................................................................... 35 4.2.2 ODU block diagram ................................................................................................. 36 4.2.3 ODU assemblies ....................................................................................................... 36 4.2.4 Sub Assembly description ......................................................................... 37 4.2.5 ODU front/rear panel overview ................................................................................ 38 4.2.6ODU Interface with BIU ............................................................................................ 40 4.3 OEU (Optic Expansion Unit) ............................................................................. 42 4.3.1 Specifications of OEU ............................................................................................... 42 Confidential & Proprietary 3/117 SC‐DAS 4.3.2 OEU block diagram ................................................................................... 43 4.3.3 OEU assemblies ....................................................................................................... 43 4.3.4Sub Assembly description ........................................................................................ 44 4.3.5 OEU front/rear panel overview.................................................................. 47 4.4 ROU (Remote Optic Unit) ................................................................................ 48 4.4.1 ROU specifications .................................................................................... 49 4.4.2 ROU block diagram ................................................................................... 50 4.4.2.1 Combination of MRU 1900PCS+850C/ARU 700LTE+AWS‐1 ........................... 50 4.4.2.2 Combination of MRU 1900PCS/ARU 900I+800I ........................................... 50 4.4.2.3 Combination of MRU 700LTE+AWS‐1.......................................................... 51 4.4.2.4 Combination of MRU 700PS+800PS ........................................................... 51 4.4.2.5 Combination of MRU 1900PCS+850C/ARU 700LTE+AWS‐1 ........................... 52 4.4.2.6 Combination of MRU 1900PCS/ARU 900I+800I ........................................... 53 4.4.2.7 Combination of MRU 700LTE+AWS‐1.......................................................... 54 4.4.3 Sub Assembly description ......................................................................... 56 4.4.4 Bottom of ROU ......................................................................................... 58 4.4.5 Top of ROU ............................................................................................... 60 4.4.5.1 Combination of MRU1900PCS+850C/ARU700LTE+AWS‐1 ............................ 60 4.4.5.2 Combination of MRU1900PCS/ARU900I+800I ............................................. 60 4.4.5.3 Combination of MRU700LTE+AWS‐1 .......................................................... 61 4.4.5.4 Combination of MRU700PS+800PS ............................................................ 61 Section5 5.1 System Installation & Operation ................................................................. 62 BIU Installation ............................................................................................... 63 5.1.1 BIU Shelf Installation ....................................................................................... 63 5.1.2 BIU Power Cabling .......................................................................................... 64 5.1.3 BIU/RF interface .............................................................................................. 66 5.1.4 MDBU installation ........................................................................................... 69 5.1.5 ODU Interface ................................................................................................. 70 5.1.6 BIU power consumption .................................................................................. 72 5.2 ODU Installation .............................................................................................. 73 5.2.1 ODU Shelf Installation ..................................................................................... 73 5.2.2 ODU Power Cabling ......................................................................................... 73 5.2.3 ODU Optic Cabling .......................................................................................... 73 5.2.4 DOU installation .............................................................................................. 74 5.2.5 ODU Power consumption ................................................................................ 75 Confidential & Proprietary 4/117 SC‐DAS 5.3 ROU Installation .............................................................................................. 76 5.3.1 ROU Enclosure installation .............................................................................. 76 5.3.2 ROU Power Cabling ......................................................................................... 83 5.3.3 Optical Cabling ................................................................................................ 84 5.3.4 GND Terminal Connection ............................................................................... 84 5.3.5 Coaxial cable and Antenna Connection ............................................................ 85 5.3.6 LED explanation on ROU ................................................................................. 86 5.3.7 ROU Power consumption ................................................................................ 86 5.3.8 Cable connection between MRU and ARU ........................................................ 87 5.4 OEU Installation .............................................................................................. 88 5.4.1 OEU chassis installation ................................................................................... 88 5.4.2 OEU Power Cabling ......................................................................................... 88 5.4.3 OEU Optic Cabling ........................................................................................... 89 5.4.4 DOU installation with an OEU .......................................................................... 90 5.4.5 OEU Power Consumption ................................................................................ 91 Section6 Operation .................................................................................................. 92 6.1 BIU Overview .................................................................................................. 93 6.1.1 BIU ................................................................................................................. 93 6.1.2 BIU TX parameters .......................................................................................... 93 6.1.3 BIU RX parameters .......................................................................................... 98 6.1.4 BIU Logic Sequence Diagram ........................................................................... 99 6.1.5 Interaction with the BIU ................................................................................ 101 6.2 ROU Overview .............................................................................................. 102 6.2.1 ROU Operation.............................................................................................. 102 6.3 OEU Operation .............................................................................................. 109 6.3.1 OEU Operation .............................................................................................. 109 Section7 7.1 Additive functions .................................................................................... 113 Shutdown function (TX output shutdown) .................................................... 114 7.2 Total Power Limit function (TX Output ALC) .................................................. 114 7.3 Automatic Output power setting function (TX Output AGC)........................... 115 7.4 Input power AGC function (TX Input AGC) ..................................................... 115 7.5 Input power limit function (TX Input ALC) ..................................................... 116 7.6 Optical loss compensation............................................................................. 116 Confidential & Proprietary 5/117 SC‐DAS Confidential & Proprietary 6/117 SC‐DAS Figures Figure 1.1 – Basic system topology supporting SISO configuration ...................... 18 Figure 2.2 – Basic system topology supporting MIMO configuration .................. 18 Figure 2.3 – Expansion system topology supporting SISO configuration ............. 20 Figure 2.4 – Expansion system topology supporting MIMO configuration .......... 20 Figure 4.1 – BIU front and side views ................................................................. 26 Figure 4.2 – BIU block diagram ......................................................................... 27 Figure 4.3 – BIU mounting diagram ................................................................... 27 Figure 4.4 – MDBU at a glance .......................................................................... 29 Figure 4.5 – MCDU at a glance .......................................................................... 30 Figure 4.6 – MCPU at a glance .......................................................................... 31 Figure 4.7 – MPSU at a glance ........................................................................... 32 Figure 4.8 – BIU front panel view ...................................................................... 32 Figure 4.9 – Rear panel view ............................................................................. 34 Figure 4.10 – ODU at a glance ........................................................................... 35 Figure 4.11 – ODU block diagram ....................................................................... 36 Figure 4.12 – ODU Internal View ........................................................................ 37 Figure 4.13 – DOU at a glance ......................................................................... 38 Figure 4.14 – 2Way Divider at a glance ............................................................... 38 Figure 4.15 – ODU front panel view ................................................................... 39 Figure 4.16 – ODU Rear panel view ................................................................... 39 Figure 4.17 BIU/ODU interface .......................................................................... 40 Figure 4.18 – BIU/ODU Interface rear view ........................................................ 40 Figure 4.19 – BIU/ODU interface details ............................................................. 41 Confidential & Proprietary 7/117 SC‐DAS Figure 4.20 – OEU at a glance ........................................................................... 42 Figure 4.21 – OEU block diagram ....................................................................... 43 Figure 4.22 – OEU internal view ........................................................................ 43 Figure 4.23 – DOU at a glance ........................................................................... 44 Figure 4.24 – EWDM at a glance ........................................................................ 45 Figure 4.25 – ECPU at a glance .......................................................................... 45 Figure 4.26 – ERFM at a glance ......................................................................... 46 Figure 4.27 – EPSU at a glance .......................................................................... 46 Figure 4.28 – OEU front panel view ................................................................... 47 Figure 4.29 – Rear panel view ........................................................................... 47 Figure 4.30 – ROU at a glance ........................................................................... 48 Figure 4.31 – ROU block diagram for MRU 1900PCS+850C and ARU 700LTE+AWS‐1 ................................................................................................................ 50 Figure 4.32 – ROU block diagram for MRU 1900PCS and ARU 900I+800I ............ 50 Figure 4.33 – ROU block diagram for MRU 700LTE+AWS‐1 ................................. 51 Figure 4.34 – ROU block diagram for MRU 700PS+800PS .................................. 51 Figure 4.35 – ROU internal view for MRU1900PCS+850C and ARU 700LTE+AWS‐1 ................................................................................................................ 52 Figure 4.36– ROU internal view for MRU 1900PCS and ARU 900I+800I .............. 53 Figure 4.37 – ROU internal view for MRU 700LTE+AWS‐1 ................................... 54 Figure 4.38 – ROU internal view for 700PS+800PS............................................. 54 Figure 4.39 – PSU at a glance ............................................................................ 57 Figure 4.40 – ROU Bottom view........................................................................ 58 Figure 4.41 – ROU Power Port View .................................................................. 59 Confidential & Proprietary 8/117 SC‐DAS Figure 4.42 – ROU Top View for MRU 1900P+850C and ARU 700LTE+AWS‐1 ....... 60 Figure 4.42 – ROU Top View for MRU 1900P and ARU 900I+800I ....................... 60 Figure 4.44 – ROU Top View for MRU700LTE+AWS‐1 ......................................... 61 Figure 4.45 – ROU Top View for MRU700PS+800PS ........................................... 61 Figure 5.1 – RACK Installation............................................................................ 63 Figure 5.2 – Power interface diagrm .................................................................. 64 Figure 5.3 – PSU LED indicator information ....................................................... 65 Figure 5.4 – BIU RF interface diagram ............................................................... 67 Figure 5.5 – BTS /BIU connections ..................................................................... 68 Figure 5.6 –BDA Interface using Circulator ........................................................ 68 Figure 5.7 –BDA Interface using Duplexer ......................................................... 69 Figure 5.8 –MDBU LED indicator information .................................................. 70 Figure 5.9 –Interface port between BIU and ODU.............................................. 71 Figure 5.10 –Cabling interface diagram between BIU and ODU ........................... 72 Figure 5.11 –SC/APC fiber termination ................................................................ 74 Figure 5.12 – ODU rear view with DOUs inserted ................................................ 74 Figure 5.13 – Wall mount dimensions for the ROU.............................................. 76 Figure 5.14 – ROU installation procedure side by side ........................................ 77 Figure 5.15 – ROU installation diagram side by side ............................................ 78 Figure 5.16 – ROU installation procedure for stacked mounting ......................... 78 Figure 5.17 – ROU installation diagram for stacked mounting ............................. 79 Figure 5.18 – ROU installation procedure for vertical rack .................................. 80 Figure 5.19 – ROU installation diagram for vertical rack...................................... 81 Figure 5.20 – ROU installation procedure for horizontal rack ............................. 82 Confidential & Proprietary 9/117 SC‐DAS Figure 5.21 – ROU installation diagram for horizontal rack ................................. 82 Figure 5.22 – ROU Power Port view ................................................................... 83 Figure 5.23 – ROU optical Port view .................................................................. 84 Figure 5.24 – ROU GND Port view ..................................................................... 85 Figure 5.25 – ROU LED indicator information ..................................................... 86 Figure 5.26 – OEU Power interface diagram ...................................................... 89 Figure 5.27 – Optical cable with SC/ACP Type Connectors................................... 90 Figure 5.28 – OEU with DOUs inserted .............................................................. 90 Figure 6.1 – SC‐DAS Link budget for the BIU ...................................................... 93 Figure 6.2 –MDBU information assigned at theBIU ............................................ 95 Figure 6.3 –MDBU menu information at the BIU ................................................ 95 Figure 6.4 –MDBU name assignment at theBIU ................................................. 97 Figure 6.5 –MDBU name assignment at the tree ................................................ 97 Figure 6.6 –MDBU Module Failure information at the BIU ................................. 98 Figure 6.7 –Configuration of BIU‐ODU‐ROU for basic topology .......................... 99 Figure 6.8 –Configuration of BIU‐ODU‐ROU for expansion topology ................ 100 Figure 6.9 –DOU assignment at the BIU .......................................................... 101 Figure 6.10 –ODU Menu information ............................................................... 101 Figure 6.11 –SC‐DAS Link budget for ROU ........................................................ 102 Figure 6.12 –Optical information at the ROU.................................................... 105 Figure 6.13 –ROU information assignment ...................................................... 106 Figure 6.14 –ROU Menu information ............................................................... 106 Figure 6.15 –ROU Softkey information ............................................................ 108 Figure 6.16 –SC‐DAS Link Budget for OEU ....................................................... 109 Confidential & Proprietary 10/117 SC‐DAS Figure 6.17 –OEU Optical information .............................................................. 111 Figure 7.1 –Shutdown logic diagram ................................................................ 114 Figure 7.2 –Optical loss information ................................................................ 117 Confidential & Proprietary 11/117 SC‐DAS Section1 Safety & Certification Notice Confidential & Proprietary 12/117 SC‐DAS “Only qualified personnel are allowed to handle this unit. Read and obey all the warning labels attached in this user manual” Any personnel involved in installation, operation or service of the SOLiD Technology repeaters must understand and obey the following: ‐ Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. ‐ The power supply unit in repeaters contains dangerous voltage levels which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. ‐ The repeater cover (door) should be securely fastened in open position(with a cord), during outdoor work in order to prevent door from slamming due to wind (which could cause bodily harm or damage). ‐ Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or replace any parts which are not sold or recommended by the manufacturer. This could cause fire, electric shock or other injuries. ‐ Repeaters generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to any person in the immediate proximity of the repeater and the repeater antennas for an extended period of time. ‐ Due to power dissipation, this repeater may reach a very high temperature. Do not operate this unit on or close to flammable materials. ‐ Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives. ‐ Signal booster warning label message should include (Class B Industrial Booster) Confidential & Proprietary 13/117 SC‐DAS ‐ Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 34.0cm (13.4 inches) minimum clearance from the antenna while the system is operating. ‐ Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24 and 90 UL/CUL: This equipment complies with UL and CUL 1950‐1 Standard for safety for information technology equipment,including electrical business equipment FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040 ‐For PLUGGABLE EQUIPMENT, the socket‐outlet shall be installed near the equipment and shall be easily accessible. Confidential & Proprietary 14/117 SC‐DAS Section2 System Overview 2.1 General overview 2.2 System overview Confidential & Proprietary 15/117 SC‐DAS 2.1 General overview SC‐DAS platform is a coverage system for in‐building services delivering seamless, high quality voice and data As a distributed antenna system, it provides analog and digital phone services in multiple bands through one antenna. The system covers public and private venues such as: Shopping malls Hotels Campus areas Airports Clinics Subways Multi‐use stadiums, convention centers, etc. The system enhances in‐building radio environments that lack signal quality by improving the RSSI and Ec/Io. By providing communication services throughout the building, the system enables users to make a calls anywhere in the coverage area. The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods. The SC‐DAS system supports communication standards and public interface protocols in worldwide use. Frequencies: VHF,UHF, 700MHz, 800MHz,850MHz 900MHz,1900MHz,2100MHz, etc. Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc. Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging,LTE, etc. SC‐DAS comprises frequency specific modules. Coverage for a specific frequency band is accomplished by inserting a corresponding frequency module into each unit. Because it delivers multiple signals with one strand of single mode fiber, the system, requires no additional hardware modifications whenever a new frequency is added. The system is featured with the following: Flexibiltiy & Scalabiltiy Supports fiber‐optic ports up to 32 or 60(using OEU) Connects multiple‐buildings (campus) as one DAS Modular structures Modular frequency upgrade Plug‐in type modules Multi‐Band, Single operator Supports multiple services from one WSP Confidential & Proprietary 16/117 SC‐DAS Support multi‐operator in a band(Max. 2 operator) Low OPEX / CAPEX Compact design Upgradable design Easy installation and maintenance Adopts auto ID scheme The SC‐DAS platform will serve two primary segments; first as a carrier deployed coverage enhancement product for their specific frequencies and second as a low cost, public safety / single carrier product. Confidential & Proprietary 17/117 SC‐DAS 2.2 System overview SC‐DAS comprises the components listed below. The base system consists of a BIU (BTS Interfcace Unit), an ODU (Optic distribution Unit) and a ROU (Remote Optic Unit). For use with multiple ROU’s, it has OEU (Optic Expansion Unit). The BIU has two layer which support both SISO and MIMO configuration using separate optical fiber cable. Fig2.1 shows basic system topology for SISO Figure 1.1 – Basic system topology supporting SISO configuration Figure 2.2 – Basic system topology supporting MIMO configuration Confidential & Proprietary 18/117 SC‐DAS As shown at Fig.’s 2.1 and 2.2, one strand of fiber is needed for SISO configuration but two strands are needed for MIMO cofiguration when connected with an ROU. Applications requiring up to 32ROU’s for SISO are possible with one BIU. Each SISO ROU will require an additional strand of fiber and an additional 32 ROU’s can be added to the same system for MIMO applications. MIMO requires 2 strands of fiber per ROU as well as MIMO specific ODU’s. Confidential & Proprietary 19/117 SC‐DAS To reduce number of optical cables between multi‐building applications, we can utilize the OEU(Optical Expansion Unit) Fig 2.3 shows expansion system topology supporting SISO configuration using OEUs Figure 2.3 – Expansion system topology supporting SISO configuration Figure 2.4 – Expansion system topology supporting MIMO configuration Fig 2.4 shows expansion system topology supporting MIMO configuration using OEU Confidential & Proprietary 20/117 SC‐DAS Section3 System Specifications 3.1 System specifications 3.1.1 Physical Specifications 3.1.2 Optic wavelength and Laser power 3.1.3 Environmental specifications 3.1.4 Available frequency bands 3.1.5 Band Specifications Confidential & Proprietary 21/117 SC‐DAS 3.1 System specifications 3.1.1 Physical Specifications Parameter RF Connectors External Alarm connector (Dry contacts) Serial Interface connector Fiber connector BIU ODU OEU MRU 1 N‐type 4 SMA pairs(TX,RX) 2 SMA per MDBU ‐ 2SMA :optical 2SMA :RF TB: 4pcs for output ‐ TB: 3pcs for input 1 USB(B) type ‐ ARU 2SMA :optical 2SMA :RF ‐ ‐ ‐ 1 USB(B) type 1 USB(B) type 1 USB(B) type 1 SC/APC for ODU ‐ System status System status 8pcs, SC/APC for 1 SC/APC for ODU ROU 8 SC/APC for ROU EWDM Status Power status ALM status DOU1 Status MCPU Status Indicator LD status PD status DOU1 Status MDBU Status LED Alarm and Power status TX Comm RX Comm ALM status MPSU Power status DC ALM status LD status PD1/2/3/4 LD status status PD1/2/3/4 DOU2 Status Power status Power status status LD status TX Comm TX Comm DOU2 Status PD1/2/3/4 RX Comm RX Comm status ALM status ALM status Opt status LD status PD1/2/3/4 System status status Power status TX1 Comm RX1 Comm TX2 Comm RX2 Comm ALM status Normal Range: 120VAC AC Power ‐ 50/60Hz ‐ Operating range Same to left side 108~132VAC,50/60Hz Normal range: ‐48 DC Power VDC Normal: ‐48 VDC Be provided by BIU Operating range: Operating range: Same to left side ‐40.8 ~ ‐57.6VDC ‐40.8 ~ ‐57.6VDC SISO Mode : 162W (Including SISO ODU 4EA) MIMO Mode : 315W consumption (Including SISO ODU 4EA+MIMO MRU1900P+850C:50W 28W Power ODU (Including DOU2EA) 40W MRU 1900P:45W ARU700LTE+AWS:40W (Including DOU2EA) MRU700LTE+AWS:50W ARU900I+800I:44W MRU700P+800P:50W 4EA) Enclosure 482.6(19”) Dimensions 221.5(5U) x 450 43.6(1U) x 450 Weight[Full Load] 26.2Kg 6Kg Confidential & Proprietary 482.6(19”) 482.6(19”) x 88.1(2U) x 450 9.6Kg 22/117 300 x 200 x 258 300 x 200 x 258 6.6Kg~7.1Kg 6.8Kg SC‐DAS 3.1.2 Optical wavelength and Laser power Parameter ODU OEU ROU West optic TX: 1310nm TX: 1550nm, RX: 1550nm East optic RX: 1310nm TX: 1550nm Optical Wavelength RX: 1310nm TX: 1310nm, RX: 1550nm 1dBm±1dBm to ROU Output power 1.5dBm±1dBm to ROU,OEU 7dBm±1dBm to ODU 7dBm±1dBm to ODU Return loss <45dB <45dB <45dB 3.1.3 Environmental specifications Parameter BIU, ODU, OEU Operating Temperature ‐10 Operating Humidity, non condensing ‐ to +50°C ROU/AOR ‐10 to +50°C 5% to 90% 3.1.4 Available Frequency Bands Standard Unit naming Description Frequency range TX(MHz) RX(MHz) Status iDEN 700PS Iden 758 to 775 788 to 805 Completed iDEN 800PS+I Iden 851 to 869 806 to 824 Completed Cellular 850C Cellular 869 to 894 824 to 849 Completed iDEN 900I Iden 935 to 940 896 to 901 Completed Paging 900 PA Paging 929 to 930 896 to 902 In future PCS 1900P PCS 1930 to 1995 1850 to 1915 Completed AWS‐1 AWS‐1 AWS‐1 2110 to 2155 1710 to 1755 Completed VHF VHF Public safety 136 to 174 136 to 174 Completed 396 to 450 396 to 450 450 to 512 450 to 512 380 to 434 380 to 434 434 to 496 434 to 496 UHF Public safety(Band1) Completed UHF E‐UHF Public safety(Band2) Completed 698 to 716 LTE 700LTE Long Term Evolution 728 to 757 Completed 777 to 787 Confidential & Proprietary 23/117 SC‐DAS 3.1.5 Band Specifications SC‐DAS platform allows many band combinations as well as different output power levels within the band depending on the combination. 1) Output power level Below table shows Output power level as a function of band combination Band Combinations MRU ARU 700PS 700LTE 800PS/I 850C 900I 1900P AWS 1900P+850C 700LTE+AWS ‐ 24dBm ‐ 24dBm ‐ 28dBm 28dBm 1900P 900I+800I ‐ ‐ 26dBm ‐ 26dBm 31dBm ‐ 700LTE+AWS ‐ ‐ 28dBm ‐ ‐ ‐ ‐ 28dBm‐ 700PS+800PS ‐ 27dBm ‐ 27dBm ‐ ‐ ‐ ‐ 1900P+AWS ‐ ‐ ‐ ‐ ‐ ‐ 30dBm 30dBm 21dBm ‐ 30dBm ‐ 1900P+850C 700PS+800PS 21dBm On the loadmap ‐ 21dBm VHF UHF 24dBm 24dBm 2) General Specifications Parameter Specifications Remark TX 25dB/step 1dB ROU RX 20dB/step 1dB BIU Gain Control range TX input power ‐20dBm~+10dBm Spurious Emission < ‐13dBm Optical Link AGC >10dB VSWR 1.8:1 Pass‐band Ripple 4dBp‐p Max optical Loss 5dBo Optical wavelength 1310nm/1550nm with WDM RX output power 0dBm RX input power ‐50dBm Max Noise Figure < 8dB Confidential & Proprietary 24/117 SC‐DAS Section4 System Configuration and Functions 4.1 BIU (BTS Interface Unit) 4.2 ODU (Optic distribution Unit) 4.3 OEU (Optic Expansion Unit 4.4 ROU (Remote Optic Unit) Confidential & Proprietary 25/117 SC‐DAS 4.1 BIU (BTS Interface Unit) The BIU receives signals from the BTS or BDA through coaxial cable and transmits to four ODUs (Optic Distribution Unit).and The BIU separates RX signals received from ODUs according to their frequency band. Figure 4.1 – BIU front and side views 4.1.1 BIU Specifications Item Spec. Remark Size 482.6(19”) x 221.5(5U) x 450 mm Weight 26 Kg SISO Mode : 168 W(Including SISO ODU 4EA) Power consumption MIMO Mode : 315W(Including SISO ODU Full Load 4EA+MIMO ODU 4EA) Confidential & Proprietary 26/117 SC‐DAS 4.1.2 BIU block diagram MCPU SISO SISO MIMO MIMO SISO MCDU MIMO MCDU M th B MPSU Figure 4.2 – BIU block diagram 4.1.3 BIU assemblies Figure 4.3 – BIU mounting diagram Confidential & Proprietary 27/117 SC‐DAS No. Unit Description Remark Main Drive BTS Unit MDBU Amplify & adjust downlink RF signal Max 4EA Amplify & adjust uplink RF signal Main Com/Div Unit MCDU Combine 3EA downlink signal and divide 4EA signal to ODU Combine 4EA uplink signal and divide 3EA signal to MDBU Support VHF/UHF interface port Main Central Processor Unit MCPU Control and monitoring system status Control and monitoring with USB(B) Allows access to upper‐level network through GSM or Ethernet MPSU Main Power Supply Unit Input power: DC ‐48V, Output power: 9V, 6V Mother Board Provide signal interface and power for each unit M/B Provide four ports for dry contact output Provide three ports for input Provide two Aux ports for future usage Shelf 19 inch, 5U 4.1.4 Sub Assembly Description 1) Main Drive BTS Unit (MDBU) MDBU delivers TX signals from the BTS or BDA to related devices as well as delivers RX signals from these devices to the BTS or BDA. This unit also monitors TX input level. Using the input AGC function, it automatically adjusts input ATT according to input power. It also has an ATT to adjust RX gain. The MDBU varies per frequency band to including the following: Confidential & Proprietary 28/117 SC‐DAS No Unit naming In/out RF Port Description TX RX 1900P+850C Dual Band 4 Port 4 Port 700LTE+AWS‐1 Dual Band 4 Port 4 Port 1900P Single Band 2 Port 2 Port 900I+800I Dual Band 4 Port 4 Port 700PS+800PS Dual Band 4 Port 4 Port 1900P+AWS‐1 Dual Band 4 Port 4 Port 2 Port 2 Port 900I On the loadmap Dual Band Figure 4.4 – MDBU at a glance 2) Main Com/Div Unit (MCDU) MCDU combines TX signals that are delivered from MDBU per frequency band and delivers them to four ODUs. It also combines RX signals from up to four ODUs and sends them to up to four MDBUs.The unit has a port to interface with VHF&UHF signals. It has an ATT for input monitoring and input control. The unit has a reserved port for future usage such as LMU interface, additive MDBU interface ,etc, Confidential & Proprietary 29/117 SC‐DAS Figure 4.5 – MCDU at a glance VHF+UHF frequency band includes the following: for use in future No Unit naming VHF+UHF Description Dual Band In/out RF Port TX RX 1 Port 1 Port 3) Main Central Processor Unit (MCPU) MCPU can inquire and control the state of the modules that are installed in the BIU. This unit can inquire and control the state of up to four ODUs. Through communication, it also can inquire and control ROUs that are connected. In addition, the unit has USB(B) port for local monitoring so that it can inquire and control state of devices through a PC. On the front panel, it has communication LED indicators to check communication state with ROU. It also has ALM LED indicators to show whether a device is faulty. For access to upper network, it has a port to insert an Ethernet port and GSM modem in it. Confidential & Proprietary 30/117 SC‐DAS Figure 4.6 – MCPU at a glance In the Main Central Processor Unit, a lithium battery is installed for RTC (Real Time Control) function. CAUTION RISK OF EXPLOSION MAY OCCUR IF BATTERY IS REPLACED BY AN INCORRECT TYPE DIPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS [INSTRUCTION] The equipment and accessories including inner lithium battery are to be disposed of safely after the life span of them according to the national regulation. Do not attempt to replace the lithium battery unless authorized by a qualified service personnel, to avoid any risk of explosion. 4) Main Power Supply Unit (MPSU) The MPSU takes a ‐48V input and outputs +6V and +9V DC power. On the front panel, this unit has an output test port and it also has DC ALM LED Indicator to show faulty output. Confidential & Proprietary 31/117 SC‐DAS Figure 4.7 – MPSU at a glance 4.1.5 BIU front/rear panel overview 1) Front panel Figure 4.8 – BIU front panel view Item 1. Alarm LED & Reset Description Communication state with devices, alarm status of the system and reset switch USB port for communication and diagnosis of devices through PC/laptop 2. DEBUG (USB B) This equipment isfor indoor use only and all the communication wirings are limited to indoor use as well. 3. NMS(Ethernet port) Ethernet port for upper network The supporting network mode is UDP protocol 4. MDBU LED LED to show whether MDBU is installed and is operating properly Confidential & Proprietary 32/117 SC‐DAS 5. RF Monitor Port 20dB Coupling compared with TX Input Level 20dB Coupling compared with RX Output Level 6. Pwr Test Port & ALM Output DC power test port and ALM LED to show abnormal state, if any 7. Power switch Power ON/OFF switch Confidential & Proprietary 33/117 SC‐DAS 2) Rear panel 10 MIMO SIDE 2 1 SISO SIDE 11 Figure 4.9 – Rear panel view Item Description 1. DC Input Port Input terminal for DC ‐48V 2. External ALM Port Input/output terminal for dry contact 3. GND Port System ground terminal 4. AUX I/O Port Reserved Port for future uses 5. MIMO ODU I/O Port RF signal interface terminal for ODU 6. MIMO ODU signal Port Power and signal interface terminal for ODU 7. MIMO BTS/BDA I/O Port Input/output interface terminal of BTS/BDA 8. V/UHF I/O Port RF signal interface terminal of VHF&UHF 9. SISO ODU I/O Port RF signal interface terminal for ODU 10. SISO ODU signal Port Power and signal interface terminal for ODU 11. SISO BTS/BDA I/O Port Input/output interface terminal of BTS/BDA Confidential & Proprietary 34/117 SC‐DAS 4.2 ODU (Optic distribution Unit) ODU receives TX RF signals from upper BIU and converts them into optical signals. The optical signals are sent to ROU through optical cables. This unit converts optical signals from ROU into RF signals and sends the converted signals to BIU. For each shelf of the ODU, up to two DOUs (Donor Optic Unit) can be installed in it. One DOU is supported with four optical ports. Therefore, one ODU can be connected with eight ROUs. Up to four ODUs can be connected with BIU each SISO and MIMO path 450 400 482.6m 43.6mm (1U) (19”) Figure 4.10 – ODU at a glance 4.2.1 ODU specifications Item Spec. Remark Size 482.6(19”) x 43.6(1U) x 450 mm Weight 6 kg Power consumption 27 W Confidential & Proprietary 35/117 Full Load SC‐DAS 4.2.2 ODU block diagram Figure 4.11 – ODU block diagram 4.2.3 ODU assemblies Confidential & Proprietary 36/117 SC‐DAS Figure 4.12 – ODU Internal View No. Unit Description Remark Donor Optic Unit DOU Converts TX RF signals into optical signals; Converts RX optical signals into RF signals; Max 2 ea. Provides up to four optical ports per DOU 2Way Divider 2W Divides TX RF signals into two; Combines two RX RF signals into one DU Shelf Accessories Distribution Unit Distributes power and signals to DOU 19” rack, 1RU 25PIN DSUB, Male to female 1pcs RF Coaxial Cable Assembly 2pcs 4.2.4 Sub Assembly description 1) Donor Optic Unit (DOU) The DOU performs the RF to optical conversion of TX signals as well as the optical to RF conversion of RX signals. Using an optical splitter, this unit divides optical signals from a Laser Diode into four and then distributes them to each optical port. With a total of four Photo Diodes in RX, the DOU performs the optical to RF conversion of signals received from each optical port. In addition, the unit is equipped with an ATT to compensate for optical loss in the fiber or fiber connectors. Since is uses a WDM, it uses only one strand of fiber for each ROU it connects to. With internal FSK modem, it will allow operation from a remote site. Confidential & Proprietary 37/117 SC‐DAS Figure 4.13 – DOU at a glance 2) 2Way Divider (2W) The 2 way divider is equipped with two 2‐way splitters in a single housing and the splitters work for TX/RX signals, respectively. Designed in broadband type, the divider combines and splits signals from/to the BIU Figure 4.14 – 2Way Divider at a glance 4.2.5 ODU front/rear panel overview 1) Front panel Confidential & Proprietary 38/117 SC‐DAS Figure 4.15 – ODU front panel view Item 1,2 Description LED indicator to check for faulty DOU module. 2) Rear panel Figure 4.16 – ODU Rear panel view Item Description 1. Optic Port SC/APC optical connector terminal; use one optical cable per ROU. 2. DC I/O Port Terminal for power and state values 3. RX RF Port RX RF signal interface terminal 4. TX RF Port TX RF signal interface terminal Confidential & Proprietary 39/117 SC‐DAS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2014:07:10 15:12:16-07:00 Create Date : 2014:07:10 15:12:16-07:00 Metadata Date : 2014:07:10 15:12:16-07:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Microsoft Word - PS) Manual_SC-MRU700PS800PS-AC Creator : dwilliams Document ID : uuid:4d90393b-11bb-4ba4-8946-07c7b7826e91 Instance ID : uuid:a4a6cb1d-99aa-4499-b29f-462d2ff4f394 Producer : Acrobat Distiller 9.5.5 (Windows) Page Count : 39 Author : dwilliamsEXIF Metadata provided by EXIF.tools