SOLiD HM700LM 5 Watt 700MHz Amplifier Module User Manual 9 User s manual REV6

SOLiD, Inc. 5 Watt 700MHz Amplifier Module 9 User s manual REV6

Manual Rev2

 Confidential & Proprietary                                      1/30 Hercules‐S(5WRemoteUnit)UserManualSOLiD,Inc.10,9thFloor,SOLiDSpace220Pangyoyeok‐ro,Bundang‐gu,Seongnam‐si,Gyeonggi‐do,Korea393‐400Tel:+82‐31‐627‐6290Fax:+82‐31‐627‐6209
 Confidential & Proprietary                                      2/30 REVISIONHISTORYVersionIssueDateNo.ofPagesInitialsDetailsofRevisionChangesV1.0Oct.23,2013 Original                      TechnicalSupportSOLiDserialnumbersmustbeavailabletoauthorizetechnicalsupportand/ortoestablishareturnauthorizationfordefectiveunits.Theserialnumbersarelocatedonthebackoftheunit,aswellasontheboxinwhichtheyweredelivered.AdditionalsupportinformationmaybeobtainedbyaccessingtheSOLiDTehcnology,Inc.websiteatwww.solid.co.krorsendemailatkehan@solid.co.krThismanualisproducedbyGlobalBusinessDivisionBusinessTeam1.PrintedinKorea.
 Confidential & Proprietary                                      3/30 ContentsSection1 Safety&CertificationNotice ......................................................................... 5 Section2 Introduction ................................................................................................ 8 2.1 Purpose ............................................................................................................. 9 2.2 HERCULES‐S ..................................................................................................... 10 Section3 FunctionalDescription ................................................................................ 11 3.1 General ........................................................................................................... 12 3.2 ComponentofHERCULES‐SRemoteUnit ........................................................... 13 3.3 Dimension ....................................................................................................... 15 Section4 SystemInstallation ..................................................................................... 16 4.1 REMOTEUNITInstallation ................................................................................ 18 4.1.1 REMOTEUNITEnclosureinstallation ................................................................. 18 4.1.2 RemoteUnitPowerCabling .............................................................................. 21 4.1.3 RemoteUnitOpticalCabling ............................................................................. 24 4.1.4 GNDTermina lConnection................................................................................. 25 4.1.5 CoaxialcableandAntennaConnection .............................................................. 26 Section5 SystemSpecifications ................................................................................. 27 5.1 PhysicalSpecifications ...................................................................................... 28 5.2 RFperformance ............................................................................................... 29 5.3 Certification ..................................................................................................... 30 
 Confidential & Proprietary                                      4/30 ContentsofFigureFigure3.1–RemoteUnitBlockDiagram ............................................................. 12 Figure3.2–InsideofRemoteUnit ...................................................................... 13 Figure3.3–RemoteUnitDimension ................................................................... 15 Figure4.1–ExteriorofRemoteUnit ................................................................... 18 Figure4.2–DimensionusedtoinstallREMOTEUNITontheWALL ........................ 19 Figure4.3–HorizontalInstallation ..................................................................... 20 Figure4.4–InstallationClearance ...................................................................... 20 Figure4.5–HowtoInstallRemoteUnit .............................................................. 20  
 Confidential & Proprietary                                      5/30 Section1 Safety&CertificationNotice
 Confidential & Proprietary                                      6/30 “OnlyqualifiedpersonnelshouldhandletheDASequipment.AnypersoninvolvedininstallationorserviceoftheDASshouldunderstandandfollowthesesafetyguidelines.”‐Obeyallgeneralandregionalsafetyregulationsrelatingtoworkonhighvoltageinstallations,aswellasregulationscoveringcorrectuseoftoolsandpersonalprotectiveequipment.‐Topreventelectricalshock,switchthemainpowersupplyoffpriortoworkingwiththeDASSystemorFiberBDA.Neverinstalloruseelectricalequipmentinawetlocationorduringalightningstorm.‐Whenworkingwithunitsoutdoors,makesuretosecurelyfastenthedoororcoverinanopenpositiontopreventthedoorfromslammingshutinwindyconditions.‐Usethisunitonlyforthepurposespecifiedbythemanufacturer.Donotmodifyorfitanysparepartsthatarenotsoldorrecommendedbythemanufacturer.Thiscouldcausefires,electricshockorotherinjuries.‐AnyDASsystemorFiberBDAwillgenerateradio(RF)signalsandcontinuouslyemitRFenergy.Avoidprolongedexposuretotheantennas.SOLiDrecommendsmaintaininga2m(78.74inches)minimumclearancefromtheantennawhilethesystemisoperating.‐Donotoperatethisunitonorclosetoflammablematerials,astheunitmayreachhightemperaturesduetopowerdissipation.‐Donotuseanysolvents,chemicals,orcleaningsolutionscontainingalcohol,ammonia,orabrasivesontheDASequipment.Alcoholmaybeusedtocleanfiberopticcablingendsandconnectors.‐Donotlookintotheendsofanyopticalfiberordirectlyintotheopticaltransceiverofanydigitalunit.Useanopticalspectrumanalyzertoverifyactivefibers.Placeaprotectivecapoveranyradiatingtransceiveroropticalfiberconnectortoavoidthepotentialofradiationexposure.‐Allowsufficientfiberlengthtopermitroutingwithoutseverebends.‐Forpluggableequipment,makesuretoinstallthesocketoutletneartheequipmentsothatitiseasilyaccessible.‐Certification FCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRParts15,22,24and90 UL/CUL:ThisequipmentcomplieswithULandCUL1950‐1Standardforsafetyforinformationtechnologyequipment,includingelectricalbusinessequipment FDA/CDRH:ThisequipmentusesaClass1LASERaccordingtoFDA/CDRHRules.Thisproductconformstoallapplicablestandardsof21CFRChapter1,SubchaperJ,Part1040‐Areadyilyaccessibledisconnectdeviceshallbeincorporatedexternaltotheequipment.‐Thispowerofthissystemshallbesuppliedthroughwiringinstalledinanormalbuilding.
 Confidential & Proprietary                                      7/30 Ifpowereddirectlyfromthemainsdistributionsystem,itshallbeusedadditionalprotection,suchasovervoltageprotectiondevice‐Only50ohmratedantennas,cablesandpassiveequipmentshallbeusedwiththisremote.Anyequipmentattachedtothisdevicenotmeetingthisstandardmaycausedegradationandunwantedsignalsinthebi‐directionalsystem.Allcomponentsconnectedtothisdevicemustoperateinthefrequencyrangeofthisdevice.‐ Only50ohmratedantennas,cablesandpassivecomponentsoperatingfrom150‐3GHzshallbeusedwiththisdevice.‐Signalboosterwarninglabelmessageshouldinclude
 Confidential & Proprietary                                      8/30 Section2 Introduction2.1Purpose2.2Hercules‐S
 Confidential & Proprietary                                      9/30 2.1 PurposeHERCULES‐Sisacoveragesystemforin‐buildingservicesdeliveringvoiceanddatainhighqualityandforseamlessly.Asadistributedantennasystem,itprovidesanaloganddigitalphonesystemsthatareservedinmultiplebandsthroughoneantenna.Thesystemcoversgeneralpublicinstitutionsandprivatefacilities. Shoppingmalls Hotels Campusareas Airports Clinics Subways Multi‐usestadiums,conventioncenters,etc.Thesystemhelpsimprovein‐buildingradioenvironmentsinpoorconditionandmakebetterpoorRSSIandEc/Io.Byprovidingcommunicationservicesateverycornerofbuildings,thesystemenablesuserstomakeacallatanysiteofbuildings.Thesystemusesbothanalog(AMPS)anddigital(TDMA,CDMAandWCDMA)methods.TheHERCULES‐Ssystemsupportscommunicationstandardsandpublicinterfaceprotocolsinworldwideuse. Frequencies:700MHz,800MHz,850MHz,1900MHz,2100MHz,etc. Voiceprotocols:AMPS,TDMA,CDMA,GSM,IDEN,etc. Dataprotocols:EDGE,GPRS,WCDMA,CDMA2000,Paging,LTEetc.HERCULES‐Sisinmodularstructureperfrequency.Toprovidedesiredfrequencyinabuilding,allyouneedtodoistoinsertacorrespondingfrequencymoduleintoeachunit.Asitdeliversmultiplesignalswithoneopticalcable,thesystem,inone‐bodytype,doesnotrequireadditionalfacilitieswhenevernewfrequencyisadded.Thesystemisfeaturedwiththefollowing: Flexibiltiy&Scalabiltiy Supportfiber‐opticportsupto32 Clusteringmultiple‐buildings(campus)asonecoverage Modularstructures Modularfrequencyupgrade Plug‐intypemodule Multi‐Band,MultiOperator
 Confidential & Proprietary                                      10/30  Signalswithapluralityofserviceprovidertransmitsimultaneously Supportmulti‐operatorinaband LowOPEX/CAPEX Compactdesign Upgradabledesign Easyinstallationandmaintenance2.2 HERCULES‐SHercules‐SisoneofseriesofAllianceDASandhas5W(+37dBm)compositeoutputpowereveryband.RDUthatisintegratedonpackagewithDuplexer,PoweramplifierandRFunitcanbemountedupto5intheenclosure.Hercules‐StransportssignalsthatmultipleoperatorsandmultipletechnologiesaremovedatasametimefromBasestationtoaremotelocationoverthesamefiber.Itisavailableinsingleandmulti‐bandconfigurationsupporting700MHz,800MHz,850MHz,1700/2100MHz,1900MHzinparallel.IthasbeenspecificllaytestedunteravariousairinterfacessuchasiDEN,GSM,CDMA2000,EV‐DO,WCDMA,LTEete.Furthermore,thereisreservedRDUslottosupport2600LTEinthefuture
 Confidential & Proprietary                                      11/30 Section3 FunctionalDescription3.1General3.2CompoentofHERCULES‐SRemoteUnit3.3Dimension
 Confidential & Proprietary                                      12/30 3.1 GeneralThefollowingfigureshowstheblockdiagramofHERCULES‐SRemoteUnit.Figure3.1–RemoteUnitBlockDiagramTherearemanycomponents; R‐Optic:RemoteOpticalUnit RCPU:RemoteCentralProcessorUnit RPSU:RemotePowerSupplyUnit RDU1‐5:RemoteDriveUnit CU:CombiningUnit
 Confidential & Proprietary                                      13/30 3.2 ComponentofHERCULES‐SRemoteUnitThefollowingfigureshowsinternalconfigurationofRemoeUnitwithfullyRFequipped.Figure3.2–InsideofRemoteUnitRemoteUnitreceivesTXopticalsignalsfromHead‐EndandconvertsthemintoRFsignals.TheconvertedRFsignalsareamplifiedthroughHighPowerAmpinacorrespondingRDU,combinedwithMultiplexermoduleandthenradiatedtotheantennaport.WhenreceivingRXsignalsthroughtheantennaport,thisunitfiltersout‐of‐bandsignalsinacorrespondingRDUandsendstheresultstoRemoteOpticModuletomakeelectronic‐opticalconversionofthem.Afterconverted,thesignalsaresenttoaupperdeviceofODU.ROUcanbeequippedwithuptofiveRDUs(RemoteDriveUnit)
 Confidential & Proprietary                                      14/30 ThefollowingtabledescribescomponentsonRemoteUnitUnitDescriptionRDU+BPFx5RemoteDriveUnitFilterandamplifyTXsignalsFilterandamplifyRXsignalsRemoveothersignalsthroughBPFRPSURemotePowerSupplyUnitInputpower:120VAC+/‐10%Outputpower:+29VDCR‐OPTICRemoteOpticMakeRFconversionofTXopticalsignals;ConvertRXRFsignalsintoopticalsignals;CompensatesopticallossCommunicateswithBIU/OEUthoughtheFSKmodem10dBoopticallinkbetweenODUandROUFiberConnector:SC/APCConnectorFiberType:SingleModeFiberOpticalWavelength:1310/1550WDMRCPURemoteCentralProcessorUnitControlssignalofeachunitMonitorsBIU/ODU/OEUthroughFSKcommunicationMultiplexerMultiplexerCombineTXsignalsfrom5RDUs;DistributeRXsignalsto5RDUs;EnableyoutouseasingleantennaportROUEnclosureEnclosuretosatisfyIP66HorizontalorVerticalMountCeilingorPoleMountInputSIUInputSystemInterfaceUnitDistributespowerandsignalstoeachmoduleOutputSIUOutputSystemInterfaceUnitInterfacingwithmultiplexer
 Confidential & Proprietary                                      15/30 3.3 DimensionFigure3.3–RemoteUnitDimensionITEMSPECIFICATION REMARKSize(Width,Height,Depth)405x960x250mm/15.94’’x37.8’’x9.84inchIncludingBracketWeight51kg/112lb FullyloadedPowerConsumption390W FullyloadedOperatingTemperature‐25to+55°C /‐13to131°FAmbientTemperatureOperatingHumidity0to90%,non‐condensing 
 Confidential & Proprietary                                      16/30 Section4 SystemInstallation5.1RemoteUnitInstallation
 Confidential & Proprietary                                      17/30 Thischapterdescribeshowtoinstalleachunitandopticalcables,alongwithpowercablingmethod.Indetail,thechapterdescribeshowtoinstallshelvesorenclosuersofeachunit,PowerCablingmethodandOpticCablingandRFInterface.Theneededaccessoriesandtoolsarelistupinthebelowtable.StepsforinstallationAccessoriesIncludedToolRemarkRemoteEnclosureInstallationM12Bolt(6EA)XSpanner(19mm)Power&OpticConnectionCableforcompressionconnector(HBG‐114‐1)XInstallationmanualprovidedbyRFSOptic:SC‐APCXPower:20020517M031B01LF(FCI)O“4mm”Screwdriver(forslottedscrew)AntennaConnectionDIN7/16CONNECTOR(Male),CoaxialcableforDIN7/16X‐ 
 Confidential & Proprietary                                      18/30 4.1 REMOTEUNITInstallation4.1.1 REMOTEUNITEnclosureinstallationREMOTEUNITisdesignedtobewater‐anddirt‐proof.TheunithasthestructureofOne‐Bodyenclosure.Itsatisfieswater‐proofandquake‐proofstandardsequivalentofNEMA4.REMOTEUNITcanbemountedoneitherceilortheWall.Basically,REMOTEUNIThasbothofaWallMountBracket.ThefollowingshowsdimensionofthefixingpointfortheWallMountBracket.Figure4.1–ExteriorofRemoteUnit
 Confidential & Proprietary                                      19/30 Figure4.2–DimensionusedtoinstallREMOTEUNITontheWALL
 Confidential & Proprietary                                      20/30 REMOTEUNITCeilMountInstallationForhorizontalinstallation,minimumseparationdistanceof130mmisrecommendedasshowninthebelowfigure.Figure4.3–HorizontalInstallationTheinstallationclearancesecuressystemreliability.Selecttherightlocationwheretheremoteunitcanbeinstalledsecurelyconsideringweightloadcapacity,therewouldbeadditionalmountingstructurescanbeappliedasshowninthebelowfigureFigure4.4–InstallationClearanceMountremoteunittothemountinglocationusingM12screws.DifferentlengthandmaterialtypeoftheM12screwscanbeselecteddependingonmountingconditionFigure4.5–HowtoInstallRemoteUnit
 Confidential & Proprietary                                      21/30 4.1.2 RemoteUnitPowerCablingRemoteUnitsupportsonlyAC120Vofinputpower.ThefollowingfigureshowsconfigurationofpowersupplyforAC120V.LugNamingRPSUTerminalnamingRemarkAC_HAC‐HAC_NAC‐NGNDFGTheprovidedconnectoris“20020517M031B01LF”ofFCIvendor.Thefollowingtableshowsmainspecificationofthisconnector.
 Confidential & Proprietary                                      22/30 Inordertoinstallthepowerconnection,firstconnectHBG‐114‐1connector(RFS)onholeatbottomofenclosure.ThisHBG‐114‐1connectorhas36.0mmdiameterandmadeofaluminum.TherecommendedcableisHYBRIFLEX(HB114‐1‐08U5‐S6F,RFS),whichconsistSM6F/O,5DCpairsand8AWG.Thecable’souterconductorarmorhavecorrugatedaluminumwithexternaljacketmadeofpolyethylence(PE). Theouterconductorgroundinghavearoletoeliminatetypicalgroundingrequirementandsavesoninstallationcosts.AfterstrippingexternaljacketofcableusingtoolintheproperandthenconnectittoHBG‐114‐1connector.FastenexternalhexnutofHBG‐114‐1connecttobefixed.Thepowerinstallationproceduresareasbelow1. Takeoff20020517M031B01LFconnectorfromRPSU2. TherecommendedwiresizeisbelowAWG#103. Select3wireamong8AWGs4. TheproperstriplengthofAWGcableis6~7mm5. Andinsertthiswireintodesignatedpositionofconnector6. SecureM3.5screwusingscrewdriverwithscrewtype“–“7. ConnectthisconnectoronRPSUandsecurescrewusingscrewdrivertofix
 Confidential & Proprietary                                      23/30 CheckiftheconnectionisthesameasoneseeninthetableaboveandmakesuretoturnthepowerON.CAUTIONDOUBLEPOLE/NEUTRALFUSINGGroundcablewithgreen/yellowcoloramong3wiresofpowercables(HOT,NEUTRAL,GND)shouldbefixedatheatsinkofenclosurebeforeconnectingwithconnectortopreventdamagefrompullingoutbyexternalstrongforce.Atthistime,secureM3.5screwusingscrewdriverwithscrewtype“+“.TherecommendedAWGis#10.
 Confidential & Proprietary                                      24/30 4.1.3 RemoteUnitOpticalCablingREMOTEUNITmakesoptical‐electronicconversionofTXsignalsfromupperODUmakeselectronic‐opticalconversionofRXsignals.REMOTEUNIThasoneopticalmoduleinit.AsWDMisinstalledintheR_OPTICmodule,twopiecesofwavelength(TX:1310nm,RX:1550nm)canbesent/receivedwithoneopticalcoreatthesametime.REMOTEUNIThasSC/APCofopticaladaptortype.Foropticaladaptor,SC/APCtypecanbeused.Topreventtheopticalaccesspartfrombeingmarredwithdirt,itshouldbecoveredwithacapduringmove.Whendevicesareconnectedthroughopticalcables,youneedtoclearthemusingalcohocoltoremovedirt.OpticalcablesshouldbeinsertedintoOpticPortoutsideofREMOTEUNIT.UsinganopticalspoolinREMOTEUNIT,youneedtocoilaroundoneortworollofcablestobeconnectedwiththeopticaladaptorofROPTIC.Atthistime,curvatureoftheopticalcableshouldbeatleast10Øtopreventinsertionlossfrombeingincreased.
 Confidential & Proprietary                                      25/30 4.1.4 GNDTerminalConnectionTheGroundTerminalislocatedatthelefsideofRemoteUnit.Groundingmustbecarriedout.Connectanearth‐bondingcabletothegroundingconnctionprovidedattheoutsideoftheRemoteUnit(atleftside).Afterlosseningthehexbolt,connecttheearth‐bondingcablebetweentheenclosureandhexbolt.Then,fastenallpartsagainwiththehexbolt.Roundterminalslocatedonthesideofa0.75mm2(18AWG)ormorewiresUsingpermanentlyconnectedtoearth(green/yellowcolor)
 Confidential & Proprietary                                      26/30 4.1.5 CoaxialcableandAntennaConnectionThecoaxialcableswhichareconnectedtoantennadistribuednetworkconnecttoantennaportofREMOTEUNIT.Beforeconnection,checktheVSWRvalueofcoaxialcablewhetheritiswithinspecificationusingSITEMASTER.Atthistime,checkiftheReturnlosshaveabove14dBorVSWRhavebelow1.5ThepartofantennaconnectionfastentoportnottobeloossenedandnottobeinjectedthedustyandinsectsTheantennaconnectedtoREMOTEUNITisonlyservicedininbuilding
 Confidential & Proprietary                                      27/30 Section5 SystemSpecifications6.1PhysicalSpecifications6.2RFPerformance6.3Certification
 Confidential & Proprietary                                      28/30 5.1 PhysicalSpecificationsParameterROURFConnectors(1)7/16DIN‐type,femaleSerialInterfaceconnector(1)RS‐2329‐pinD‐sub,maleFiberconnector(1)SC/APCforODULEDAlarmandStatusIndicatorPowerLEDTXLEDRXLEDLDLEDPDLEDALARMLEDRESETButtonACPowerNormalRange:120VAC50/60HzOperatingrange108~132VAC,50/60HzPowerconsumption390W(ROUw/5RDUs)EnclosureDimensions(mm)405x960x250mm/15.94’’x37.8’’x9.84inchWeight(FullLoad)51kg/112lbMaterial(Exterior)2mmAluminumSafetyULLabeledCertificationsUL,FCC
 Confidential & Proprietary                                      29/30 5.2 RFperformanceSupported Services Supported Services  700LTE   Full Band 800 Sprint/850 Cellular 1900 PCS 2100 AWS Frequency Range Tx (MHz)  728-756  862-894  1930-1995  2110-2155 Rx (MHz)  698-716 777-787  817-849  1850-1915  1710-1755 Bandwidth Tx (MHz)  28  32  65  45 Rx (MHz)  18 10  32  65  45 RF Parameters Input Power   Tx (dBm)  -20 to +10  -20 to +10  -20 to +10  -20 to +10 Rx (dBm)  ≤ -50  ≤ -50  ≤ -50  ≤ -50 Output Power  Tx (dBm)  37  37  37  37 Rx (dBm)  0  0  0  0 System Gain Tx (dBm)  57  57  57  57 Rx (dBm)  50  50  50  50 System Delay Tx  < 8µs  < 8µs  < 8µs  < 8µs Rx    < 8µs  < 8µs  < 8µs  < 8µs Impedance  Tx (ohm)  50 Rx (ohm)  50 Spurious Emissions  Tx  ≤ -13dBm @ 9kHz – 5GHz Out of Band Attenuation    Rx  ≤ 45dB @ F_edge ± 1MHz offset Gain Control Range/Step Tx  25dB/step 1dB Rx  20dB/step 1dB Optical Optic Wavelength Tx  1310nm WDM Rx  1550nm WDM Optic Link AGC  Above 10dB Optic Link Loss  Max 10dBo Noise Figure  8dB Max Optical Connector  SC-APC (Single Mode Fiber) RF Connector  DIN-F (Common Output), N-F (UHF/VHF and AOR) Monitoring Port  -30dB (SMA Female) 
 Confidential & Proprietary                                      30/30 5.3 CertificationTitleStandards RemarksEnvironmentalTemperatureange‐25°Cto+55°C/‐13to131°FAmbientTemperatureHumidityRange0%~90%Non‐condensingTransportationETSIEN300019‐1‐2IEC60721‐3‐2Class2.3Classes2K2/2M2StorageETSIEN300019‐1‐1IEC60721‐3‐1Class1.2Classes1K2/1M3Sealing(RemoteUnit)IEC60529EN60529IP66ComplaintProductsafetyTypeapprovalsandcertificationsNorthAmericaUL60950‐1,2ndEditionCSAC22.2No.60950‐1‐07,2ndEdition,CSAC22.2No.ULCertificationNorthAmericaFCCPart24SubpartDandPart90SubpartIFCCPart22SubpartHandPart27SubpartCFCCPart24SubpartEandPart27SubpartCFCCCertificationCanadaRSS‐131(ISSUE2)ICCertificationEMCEmissionNorthAmericaFCCPart15SubpartB,ClassAFCCVerificationMTBFMeanTimeBetweenFailuresNorthAmericaTelcordiaSR‐332Issue2Fits:(FailureUnit)MTBF=ROUFailureRate=11,823MTBF=9.65Years FullyloadedROU

Navigation menu