ST Engineering Telematics Wireless XMETER5 Water Meter Transceiver User Manual TMW 40U NTAXMETER5 Rev 2 0

Telematics Wireless Ltd. Water Meter Transceiver TMW 40U NTAXMETER5 Rev 2 0

Users Manual

Download: ST Engineering Telematics Wireless XMETER5 Water Meter Transceiver User Manual TMW 40U  NTAXMETER5  Rev 2 0
Mirror Download [FCC.gov]ST Engineering Telematics Wireless XMETER5 Water Meter Transceiver User Manual TMW 40U  NTAXMETER5  Rev 2 0
Document ID296307
Application IDx6Trg5hbgquwQBIt9++udQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.4kB (354955 bits)
Date Submitted2003-01-16 00:00:00
Date Available2003-01-15 00:00:00
Creation Date2003-01-16 16:46:47
Producing SoftwareAcrobat PDFWriter 4.05 for Windows NT
Document Lastmod2003-01-16 12:12:22
Document TitleUser Manual TMW-40U _NTAXMETER5_ Rev 2.0.doc
Document CreatorUser Manual TMW-40U (NTAXMETER5) Rev 2.0 - Microsoft Word
Document Author: Valeria

Draft
User Manual
TMW-40U
TMW-40U
FCC ID: NTAXMETER5
Manufacturer: Tadiran-Telematics Ltd.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Note:
The digital portion of the transceiver has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Draft
Installation
Following information will be included in the User Manual
The user and the installer should be aware that changes and modifications not
expressly approved by Tadiran Telematics could void the user’s authority to
operate the equipment.
This equipment shall be installed by professional personnel.
The equipment shall be installed at a distance of 3 to 6 inch from the top cover
of the water meter pit as described in the following picture:
Draft
There are 3 types of the pits: metal, concrete and plastic. The covers of the pits
are made of metal, concrete or plastic and, in case of concrete or plastic pits,
may or may not include small rectangular lid at the center of the cover. The
lids can be either metal or plastic. Allowable configurations of the pits and its
covers are shown on the following pictures:
Metal Pit
Concrete Pit w. concrete cover
and metal lid
Plastic Pit w. plastic cover
and metal lid
Plastic Pit w. plastic cover and
plastic lid
Plastic Pit w. concrete cover
and metal lid
Plastic Pit w. plastic cover and
no lid
Concrete pit with concrete
cover and no lid
Draft
Special instructions for installation in the concrete or plastic pits.
When installing the equipment in the pit made of plastic or concrete, regardless of the
type of the cover, a special adhesive sticker shall be attached to the unit as described
in the drawings (see attached picture).
The sticker is copper foil sticker (e.g. type 3M 1181, PPI 9115 or compatible),
intended for permanent adhesion. Stickers used for the product are produced with
special adhesive and are designed to withstand the installation conditions during the
lifetime of the product.
Only stickers, supplied as a part of the installation kit of the meter, shall be used. Use
of stickers unauthorized by the manufacturer is prohibited.
Sticker adhesion position along the line
Draft

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2003:01:16 16:46:47Z
Modify Date                     : 2003:01:16 12:12:22-05:00
Page Count                      : 5
Creation Date                   : 2003:01:16 16:46:47Z
Author                          : Valeria
Producer                        : Acrobat PDFWriter 4.05 for Windows NT
Mod Date                        : 2003:01:16 12:12:22-05:00
Metadata Date                   : 2003:01:16 12:12:22-05:00
Title                           : User Manual TMW-40U _NTAXMETER5_ Rev 2.0.doc
Creator                         : Valeria
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NTAXMETER5

Navigation menu