STL WP-2 Wireless Pendant User Manual WP2 Instrux

STL International Ltd. Wireless Pendant WP2 Instrux

User Manual

Wireless Pendant™ WP-2Operating InstructionsNOTE: The Pendant is water-resistant, that is, it can withstand limited exposure to liquids.  However, it is not waterproof, and should not be immersed in any liquid.Universal Medical Products’ Wireless Pendant™ can be used inplace of or along with a Transmitter (model WT-2) in the UMPWireless Sentry™ monitoring system to send an emergency alarmsignal to the Receiver (model WR-3 or WR-4).  It can be worn eitheraround the neck or on the wrist.  It operates on three LR44 1.5Vbutton cell batteries (included).  On Standby status, these batterieswill last for approximately 3 years.  We recommend that you test thePendant periodically to be sure the batteries are working.  If thecommunication distance or the brightness of the alarm LED isreduced, replace all three batteries with new ones.To replace batteries1.Remove the two screws on the back of the Pendant and lift off the front of the casing.2.Pry out the old batteries with a pen or small screwdriver.3.Place the new batteries into position, being sure to align the polarities correctly.  Match the “+” sign on the batteries with the “+” marked in the battery compartment.4.Before screwing the front of the unit back into place, press the blue circle to be sure the batteries have been installed correctly and are operational.  The LED should go on.5.Reprogram the device if necessary (see below).ProgrammingThe Pendant can activate the Receiver after being programmedas described below:1.Press and hold the PROGRAM button of the Receiver until the green PROGRAM LED lights up.  The LED indicating the first empty station location will flash.2.Press the PROGRAM button to select the desired empty location.  The LED of each empty station will light up in turn each time the button is pushed.1
3.Press and hold the ALARM button (blue circle) on the Pendant until you hear a long beep from the Receiver and the station LED stops flashing.  4.Press the PROGRAM button to program the next empty station, ORPress CONFIRM on the Receiver to return to normal monitor mode. OperationIn an emergency, the Receiver can be activated using the Pendant. Pressing the ALARM button once will transmit the alarm signal tothe Receiver for approximately 3 minutes.  The alarm sound on theReceiver will be activated.  The LED on the Pendant will flash to help the caregiver identify the source of the alarm signal.To stop the alarm sound on the Receiver, press the ALARM RESETbutton on the Receiver.  The corresponding location LED will also go off.  The Pendant will be disabled for about 6 seconds after sendingthe alarm signal.  After this time, the Pendant will reset itselfautomatically and can then be used again.For more details on the operation of the Wireless Sentry system,see the Operator’s Manual included with the Receiver. 2
FCC WarningChanges or modifications to this unit not expressly approved by theparty responsible for compliance could void the user’s authority tooperate the equipment.Radio Frequency InterferenceThis equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation.  This equipmentgenerates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may causeharmful interference to radio communications.However, there is no guarantee that interference will not occur in aparticular installation.  If this equipment does cause harmfulinterference to radio or television reception which can bedetermined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of thefollowing measures.•Increase the separation between the equipment andreceiver.•Connect the equipment into an outlet on a circuit differentfrom that on which the receiver is needed.Consult the dealer or an experienced radio/TV technician for help.3
Limited WarrantyUNIVERSAL MEDICAL PRODUCTS, INC., guarantees the qualityand workmanship of the Wireless Sentry™ Receiver and eachTransmitter (including Pendant) and Charger for a period of one (1)year from date of purchase.  This warranty is in force provided thereis no evidence of misuse or improper installation.Under the conditions of this warranty, UNIVERSAL MEDICALPRODUCTS, INC., agrees to repair and return any defective orinoperative Wireless Sentry™ units, components, or parts within 30days without charge.Units, components or parts that are determined not to be covered by this warranty because of time, abuse/misuse, or improperinstallation, will be repaired or replaced on an established costrepair basis within 30 days.UNIVERSAL MEDICAL PRODUCTS, INC., DOES NOT CLAIMTHAT THE WIRELESS SENTRY™ SYSTEM WILL PREVENTBED- AND CHAIR-RELATED FALLS WITHOUT FAIL.  IT DOESCLAIM THAT, WITH A COORDINATED EFFORT FROM THEINSTITUTION NURSING STAFF AND AN ACCEPTABLE FALLSPREVENTION PROGRAM, THE WIRELESS SENTRY™ SYSTEMCAN HELP TO REDUCE THE NUMBER OF FALLS THAT OCCURWITHIN AN INSTITUTION.All questions or inquiries should be directed to:UNIVERSAL MEDICAL PRODUCTS, INC.1620 N. 20th CircleLincoln, NE 68503-1103Tel.: (888) 716-0077 (Toll Free)  or  (718) 499-0020    Fax: (732) 583-6923  or  (718) 499-64944Printed in China

Navigation menu