SYM Technology UWMS-01 Universal Wireless Monitoring System UWMS-01 User Manual

SYM Technology, Inc. Universal Wireless Monitoring System UWMS-01 Users Manual

Users Manual

Download: SYM Technology UWMS-01 Universal Wireless Monitoring System UWMS-01 User Manual
Mirror Download [FCC.gov]SYM Technology UWMS-01 Universal Wireless Monitoring System UWMS-01 User Manual
Document ID1108985
Application IDIyezVrxHmUNeFA79L/FjuQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize76.94kB (961725 bits)
Date Submitted2009-05-12 00:00:00
Date Available2009-05-12 00:00:00
Creation Date2009-01-22 23:55:34
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2009-01-22 23:55:34
Document TitleMicrosoft Word - SYM_UWMS-01_User Manual_V.2.0_Jan.2009
Document CreatorPScript5.dll Version 5.2.2
Document Author: Vincent

User Manual UWMS‐01 Version 2.0
Table of Contents
I.
Introduction
A. What is the UWMS‐01?.............................................................................................
B. What is in the Box?....................................................................................................
C. UWMS‐01 at a Glance…………………………………………………………………………………………….. 4
II. Installation Overview…………………………………………………………………………………………………… 5
III. Setting up the UWMS‐1 Using Graphic User Interface
A. Network Status………………………………………………………………………………………………………
B. Network Connection………………………………………………………………………………………………. 10
C. Dry Contact Set‐up…………………………………………………………………………………………………. 13
D. UWMS‐01 Set‐up……………………………………………………………………………………………………. 15
E. Firmware Update……………………………………………………………………………………………………. 18
F. Administrator…………………………………………………………………………………………………………. 19
G. UWMS‐01 Information…………………………………………………………………………………………… 20
H. Logout……………………………………………………………………………………………………………………. 20
IV. Troubleshooting…………………………………………………………………………………………………………… 21
V. Technical Specifications
A. Electrical Specifications…………………………………………………………………………………………… 22
B. Environmental Specifications…………………………………………………………………………………. 22
C. Mechanical Specifications………………………………………………………………………………………. 22
VI. Safety and Warranty Information
A. General Precaution………………………………………………………………………………………………… 23
B. Radio Frequency (RF) Energy………………………………………………………………………………….
23
C. Specific Absorption Rates (SAR)……………………………………………………………………………..
23
D. FCC Notice………………………………………………………………………………………………………………. 23
E. Manufacturer’s Limited Warranty ………………………………………………………………………….. 24
VII. Glossary ………………………………………………………………………………………………………………........
25
User Manual UWMS‐01 Version 2.0
I. Introduction
A. What is the UWMS‐01?
The Universal Wireless Monitoring System (“UWMS‐01”) enables Sprint to monitor and control its
network devices (“Devices”) such as repeaters and DAS remotely and wirelessly. Due to its universality,
any HTTP‐based devices with standard Ethernet interface can be connected to the UWMS‐01. Using the
UWMS‐01 Sprint will be able to access the Devices connected to the UWMS‐01 to monitor them or
change their parameters without visiting the physical site. This wireless monitoring and control
capability enables Sprint to proactively diagnose and troubleshoot problems remotely even before a
customer complaint is received. This translates into less network management costs and increased
customer satisfaction.
This means anytime, anywhere access to Sprint’s Devices from everywhere.
‐ Higher data throughput using 1xEV‐DO Rev. A wireless module
‐ Managing multiple devices (up to 8 repeaters or 32 DAS remote nodes) simultaneously
‐ Built‐in 10/100 Mbps switching HUB
‐ Eight Ethernet ports
‐ Conversion of dry contact alarms to SNMP alarms
‐ Tested compatibility with the following Devices:
ADRF Repeaters, Andrew ION™‐B, Dekolink Repeaters, GS Teletech Repeaters, LGC Fusion®,
MobileAccess 410, SK Telesys Repeaters, and R‐tron Repeaters.
The UWMS‐01 works seamlessly with multiple Devices from the different manufacturers listed above.
For the most recent list of compatible Devices, please visit www.symtechnology.com.
© 2008~2009 SYM. All rights reserved.
Page 2
User Manual UWMS‐01 Version 2.0
B. What is in the Box?
No
Item
UWMS‐01 Main Body
Ethernet Cable
Mounting Screws
Dipole Antenna
N to SMA Connector Adaptor
DC Power Cord
AC Power Cord
DE‐15 male to male Cable
Quick Start Guide
© 2008~2009 SYM. All rights reserved.
Part Number
UWMS01
UWMS01ET
UWMS01SC
UWMS01AT
UWMS01NS
UWMS01DC
UWMS01AC
UWMS01DR
UWMS01QG
Qty
Page 3
User Manual UWMS‐01 Version 2.0
C. UWMS‐01 at a Glance
© 2008~2009 SYM. All rights reserved.
Page 4
User Manual UWMS‐01 Version 2.0
II. Installation Overview
Drawing 1 shows a typical installation when the UWMS‐01 is set up with its supplied dipole antenna.
Make sure the received signal strength is greater than ‐85 dBm at the installation site.
Drawing 1 – Connecting the UWMS‐01 to a DAS using a dipole antenna
If sufficient signal is not present at the installation site, you have a few options: (1) You can couple the
stronger signal from the Device’s donor port using an RF coupler. (See Drawing 2.);
Drawing 2 – Connecting the UWMS‐01 to a repeater of which donor
signal is coupled to the UWMS‐01’s antenna port
© 2008~2009 SYM. All rights reserved.
Page 5
User Manual UWMS‐01 Version 2.0
(2) You can place the UWMS‐01 where there is a Sprint signal greater than ‐85 dBm. But, make sure the
distance between the UWMS‐01 and the Device does not exceed approximately 328 feet (100 meters);
or (3) You can place the UWMS‐01 near the Device but place the supplied dipole antenna where there is
a Sprint signal greater than ‐85 dBm using an extension coaxial cable.
1. In order to set up the UWMS‐01, you have to change the Device’s network configuration first.*
(*Device is the Sprint‐approved network equipment, e.g., repeaters and DAS that you want to monitor
using the UWMS‐01. We assume that all Devices have HTTP‐based local GUI. Please contact the Device
manufacturer if you do not know how to access the local GUI of the Device and how to change its
settings.)
a. Change the Device’s IP address and Site ID (Cascade code) to the following:
IP address: 192.168.1.XX (XX can be any number from 2 to 99)**
Subnet mask: 255.255.255.0
Default gateway: 192.168.1.100
Manager IP: 10.22.25.15
Site ID (Cascade code): Unique Site ID assigned by Sprint
(**When you connect multiple Devices to the UWMS‐01, assign different IP addresses to the
Devices, e.g., 192.168.1.2, 192.168.1.3, and 192.168.1.99. Also, each Site ID (Cascade code)
must be unique for each Device.)
Alternative Set‐up:
IP address: Subnet mask: Default gateway: If the Device does not allow you to change its static
IP address and has the DHCP client feature, the UWMS‐01 will assign the IP address
automatically.
Manager IP: 10.22.25.15
Site ID (Cascade code): Unique Site ID assigned by Sprint
b. Make sure the Device’s heartbeat mode is on and set heartbeat period to 20 minutes.***
(***For testing purposes you may want to set a shorter heartbeat period, e.g., 1 minute. Make
sure to change it back to 20 minutes before you leave the installation site.)
c. Make sure the Device has GPS (latitude/longitude of the site) information stored. If GPS
information is missing, Sprint NOC will not accept heartbeats from the site.
d. Make sure the Device is working properly.
2. Connect the UWMS‐01 to the Device as shown above in Drawing 1 or Drawing 2.
a. Using the supplied Ethernet cable, connect Device to the UWMS‐01’s Ethernet port.
© 2008~2009 SYM. All rights reserved.
Page 6
User Manual UWMS‐01 Version 2.0
b. The UWMS‐01 can be powered by the supplied AC adapter (UWMS01AC) or by DC power cord
(UWMS01DC) if Device has a 12VDC outlet. Using AC power is recommended.
c. Using the supplied Ethernet cable, connect your laptop to the UWMS‐01’s Ethernet port.
d. Turn on the UWMS‐01.
3. Change your laptop’s Local Area Connection setting.
a. Go to Network Connections > Local Area Connection > Internet Protocol (TCP/IP) Properties.
Select “Obtain an IP address automatically.” It may take a few minutes to obtain an IP address.
b. Alternatively, you can select “Use the following IP address” and input the following
information:
IP address: 192.168.1.200
Subnet mask: 255.255.255.0
Default gateway: 192.168.1.100
4. Configure the UWMS‐01.
a. Open Microsoft Internet Explorer and type the following URL:
http://192.168.1.100:8888
b. When prompted, input the following User Name and Password:
User Name: sym
Password: sym
c. Go to UWMS‐01 Set‐up menu and input the following information, then click Apply.
Site ID (Cascade code): Change “SYMTEST” to the Site ID provided by Sprint
Latitude: Input the latitude information N/S +ddd.dddddd
Longitude: Input the longitude information E/W –ddd.dddddd
Heartbeat Interval: 20 minutes
Heartbeat On/Off: On
For more detailed instructions, refer to Chapter III. D. UWMS‐01 Set‐up on page 15.
d. Go to Network Device Status menu and check whether the Devices are automatically
registered in the Network Device Status table.
For more detailed instructions, refer to Chapter III. A. Network Status on page 9.
e. Visual inspection: Confirm from the UWMS‐01’s front panel that the LEDs show normal
operation as follows:
© 2008~2009 SYM. All rights reserved.
Page 7
User Manual UWMS‐01 Version 2.0
Power LED is lit in solid green
Status LED blinks periodically when in normal operation
PPP LED is lit in solid green when PPP session is on
Data LED blinks in green only when data is being transmitted
Corresponding CH‐LED(s) to which Devices are connected are
lit in green
f. Congratulations! The Devices can be monitored and controlled through Sprint networks
wirelessly and remotely.
© 2008~2009 SYM. All rights reserved.
Page 8
User Manual UWMS‐01 Version 2.0
III. Setting up the UWMS‐01 Using Graphic User Interface
The UWMS‐01’s GUI consists of eight (8) intuitive, easy‐to‐follow menus. When you logged in as a
Member, you will see seven (7) menus. Only the Administrator can see the Administrator menu.
A. Network Status
Picture 1. Network Status Menu Screenshot
(1) Network Status gives you at‐a‐glance overview of the Devices connected to the UWMS‐01.
(2) You can open/save/print the UWMS‐01’s User Manual.
(3) The Modem Status displays the UWMS‐01’s modem connection status (On‐Line/Off‐Line).
(4) Network Device Status:
The Network Device Status displays the information of the Devices connected to the UWMS‐01. A total
of 32 Devices can be displayed in the table. When the UWMS‐01 receives heartbeats from the Devices
periodically, the Device information is in black. If more than 24 hours pass without receiving a single
heartbeat from a Device, the Device is indicated in red, indicating inactivity. This will turn black again
when the UWMS‐01 starts receiving heartbeats from the previously dormant Device.
© 2008~2009 SYM. All rights reserved.
Page 9
User Manual UWMS‐01 Version 2.0
B. Network Connection
You can add or delete Devices manually.
Picture 2. Network Connection Menu Screenshot
You can add Devices to the UWMS‐01 either automatically or manually. When you connect a Device,
simply wait until the Device starts sending out a heartbeat to the UWMS‐01. If the Device’s Site ID and
Static IP are set up correctly, and the Device is sending out a heartbeat, the UWMS‐01 will receive the
Device’s heartbeat information and register the Device automatically. Alternatively, you can manually
input the Device’s information (Site ID, Static IP, Model, and Type) in the Add New Device table.
(1) Add New Device: Type in the necessary information (Site ID and Static IP address) and
then click the plus sign. You will see the information added in the Network Device Status
table. If the Site ID or Static IP information is missing, the following dialogue box will
appear:
Picture 3. Information Missing Dialogue Box
© 2008~2009 SYM. All rights reserved.
Page 10
User Manual UWMS‐01 Version 2.0
You can add up to 32 different Devices to the UWMS‐01. If you attempt to add more than
32 Devices, the following dialogue box will appear:
Picture 4. Devices Maxed Out Dialogue Box
Site ID: Device’s unique Cascade code provided by Sprint. The Site ID can be up to 35 alpha‐numeric
characters, upper and lower cases. Do not use spaces or special characters. All Site IDs must be unique.
When you input a Site ID that is already registered, the following dialogue box will appear:
Picture 5. Identical Site ID Exists Dialogue Box
Static IP address: Device’s fixed IP address assigned by installer. The Static IP must follow the proper
format and the IP address must be within the range specified, e.g., 192.168.1.XX (XX can be any
number from 2 to 99). (See also II. Installation Overview 1. (a) Change Device’s IP address and Site ID on
Page 6.) When the Static IP is either in the wrong format or out of the range, the following dialogue box
will appear:
Picture 6. Input Correct Static IP Address Dialogue Box
© 2008~2009 SYM. All rights reserved.
Page 11
User Manual UWMS‐01 Version 2.0
Model and Type information are optional. You will be able to register the Device without inputting the
Model and Type information. However, the Site ID and Static IP address must be provided.
Model: Alpha‐numeric up to 25 characters showing Device model name.
Type: Alpha‐numeric up to 20 characters indicating Device type, e.g., RF Repeater, DAS, Router, UPS, etc.
(2) Network Device Status: The table displays all the Devices connected to the UWMS‐01. A
maximum of 32 Devices can be displayed in the table. If you want to remove a Device,
simply click the red button in the Delete column. The following dialogue box will appear to
confirm:
Picture 7. Deletion Confirmation Dialogue Box
© 2008~2009 SYM. All rights reserved.
Page 12
User Manual UWMS‐01 Version 2.0
C. Dry Contact Set‐up
Some legacy Sprint Devices do not have Ethernet interface, e.g., MA 410. Devices which have dry
contact alarms can still be connected to the UWMS‐01 through the UWMS‐01’s dry contact port. The
UWMS‐01 can receive up to four (4) dry contact alarms and convert these to one of the five (5) SNMP
alarms defined in the Sprint MIB.
There are four (4) LEDs on the bottom of the UWMS‐01, matching the four (4) dry contact alarms. When
an alarm event occurs, the corresponding dry contact LED will be lit in solid green. When the alarm
clears, the LED will be off.
Picture 8. Dry Contact Set‐up Screenshot
(1) Add New Dry Contact Alarm: Assign a proper Port number (1~4), input Site ID provided by
Sprint, select one of the 5 alarms with which you want to associate the dry contact alarm,
then click the blue plus sign. If you select “RF Power,” when alarm event occurs, Sprint NOC
will see the event as “RF Power” alarm. Model and Type information are not required.
(2) Dry Contact Alarm Status: The table shows the information of the registered dry contact
alarm. You can delete the Device by clicking the red button in the Delete column.
© 2008~2009 SYM. All rights reserved.
Page 13
User Manual UWMS‐01 Version 2.0
(3) Connector: The UWMS‐01 has a 3‐row DE‐15 female connector, same as the VGA (RGB)
connector.
(4) Connector Pin Map: Please refer to the pin map information in the table when you connect
a Device with dry contact alarm. The supplied DE‐15 male to male cable only works with the
MA 410. You may need a customized cable to have your Device work with the UWMS‐01.
Please contact our technical support if you need further assistance.
Pin
Function
Pin
Port 3 Normal Open
Port 4 Common
11
Port 1 Common
Port 3 Normal Close
Port 2 Normal Open
12
Port 2 Common
Port 3 Common
Port 1 Normal Close
13
Port 2 Normal Close
Port 4 Normal Open
Not Connected
14
Not Connected
Port 4 Normal Close
10
Not Connected
15
Port 1 Normal Open
© 2008~2009 SYM. All rights reserved.
Function
Pin
Function
Page 14
User Manual UWMS‐01 Version 2.0
D. UWMS‐01 Set‐up
10
Picture 9. UWMS‐01 Set‐up Menu Screenshot
(1) Site ID & Manager IP: Type in the Site ID assigned by Sprint. SNMP Manager IP is the target
IP to which the UWMS‐01’s data is directed. Use 10.22.25.15 (default value) as the SNMP
Manager IP unless you are told otherwise. Click the orange Apply button to effectuate the
change.
(2) Heartbeat Control:
i.
Latitude and Longitude: Type in the GPS information of the site where the UWMS‐01 is
installed. Without the location information, heartbeats will not be generated. The
latitude format is (‘N/S’) (+/‐) ddd.dddddd, e.g., N +39.006957. The longitude format is
(‘E/W’) (+/‐) ddd.dddddd, e.g., W ‐94.532306. To effectuate the change, click Apply.
ii.
Heartbeat Interval: Set the heartbeat interval from 1 to 60 minutes using the drop‐down
box. The default interval is 20 minutes. To effectuate the change, click Apply.
Heartbeat On/Off: You can turn off the heartbeat. However, it is advised that you
always turn on the heartbeat when the UWMS‐01 is in operation. To effectuate the
change, click Apply.
iii.
© 2008~2009 SYM. All rights reserved.
Page 15
User Manual UWMS‐01 Version 2.0
(3) UWMS‐01 IP Address:
i.
IP Address: The UWMS‐01’s default IP address is 192.168.1.100. If you change the
default IP address, the following dialogue box will appear to confirm. In case where you
assigned your laptop’s IP address manually (as opposed to “Obtain an IP automatically”),
you must change your laptop’s Local Area Connection accordingly to connect to the
UWMS‐01. In order to open the UWMS‐01’s GUI program, you will need to login again
and type in the new IP address.
http://192.168.1.100:8888/device_setup.asp (Default)
http://New IP Address:8888/device_setup.asp (New)
Picture 10. UWMS‐01 IP Address Change Dialogue Box
The Member is not allowed to change the UWMS‐01’s IP address. Only the Administrator can change
the IP address.
ii. Subnet Mask: The default Subnet Mask is 255.255.255.0.
(4) DHCP Control: If you cannot assign a Static IP address to the Device and the Device has a
DHCP client, the DHCP server of the UWMS‐01 will automatically assign an IP address to
the Device connected. The IP addresses assigned by the UWMS are within the range from
192.168.1.110 to 192.168.1.199. The default DHCP mode is on.
(5) Apply: To effectuate changes you make in (1) through (4), click Apply then the page will
refresh.
(6) Modem Reset: You can manually force the modem to re‐register on the network by
clicking Modem Reset. When you are connected remotely, you need to login again after
you reset the modem.
Picture 11. Modem Reset Confirmation Dialogue Box
The UWMS‐01 automatically terminates the PPP session and re‐registers every hour automatically.
© 2008~2009 SYM. All rights reserved.
Page 16
User Manual UWMS‐01 Version 2.0
(7) Reboot: You can restart the UWMS‐01 by clicking Reboot. If you click OK, your current
Web browser will be closed, and after 2~3 minutes, you can login again.
Picture 12. Reboot Dialogue Box
The UWMS‐01 automatically reboots itself every 12 hour to protect itself from an unexpected
interruption of operation and memory shortage.
(8) View Log: By clicking View Log, you can see some vitals of the UWMS‐01 in text format.
(9) Load Configuration: By clicking Load Configuration, you can download the configurations
that you had previously saved. It is especially convenient when you have to replace an
UWMS‐01 with a new unit. You do not need to set up the UWMS‐01 again. By simply
downloading the saved configuration, you can restore the configuration that you had
previously saved.
(10) Save Configuration: You can save the current UWMS‐01 configurations to your laptop for
future reference.
© 2008~2009 SYM. All rights reserved.
Page 17
User Manual UWMS‐01 Version 2.0
E. Firmware Update
You can update the UWMS‐01’s firmware.
Picture 13. Firmware Update Menu Screenshot
(1) File Name: Click Browse and locate the firmware on your laptop. Then click the Update
button.
(2) Update: When the firmware is downloaded and updated successfully, the following
dialogue box will appear. When you click OK, the UWMS‐01 will restart.
Picture 14. Update Successful Dialogue Box
© 2008~2009 SYM. All rights reserved.
Page 18
User Manual UWMS‐01 Version 2.0
F. Administrator
You can manage user accounts that can access the UWMS‐01 by assigning different levels of access
rights.
Picture 15. Administrator Menu Screenshot
The Administrator Menu is only available when you are logged in as the Administrator (Super User).
When a Member logs in, the Member cannot access the Administrator Menu.
(1) Account Management: Displays the User Name and Password of all the registered
accounts. To delete an account, click the red button under the Edit column.
(2) New Account: To create a new account, click New Account, type in new User Name and
Password, then click Apply. User Name and Password can be up to 15 alpha‐numeric
characters. They are case‐sensitive. Do not use any spaces or special characters.
(3) Administrator: You can change the Administrator’s account information only when you
are logged in as the Administrator. The default User ID and Password are admin for both.
© 2008~2009 SYM. All rights reserved.
Page 19
User Manual UWMS‐01 Version 2.0
G. UWMS‐01 Information
Picture 16. UWMS‐01 Information Menu Screenshot
(1) UWMS‐01 Information: Displays the UWMS‐01’s system information, including its
firmware version and serial number. Please have the information handy, when you
contact SYM’s technical support.
(2) EVDO Module Information:
Model: Displays the manufacturer and the model of the module which resides in
the UWMS‐01.
MDN: Displays the Modem Directory Number.
ESN: Displays the modem’s Electronic Serial Number.
Channel: Displays the channel number which was assigned by the nearest BTS.
RSSI: Displays the received signal strength for voice (CDMA) and data (EVDO)
separately.
H. Logout
When you logout, you will see a confirmation pop‐up window. When you hit OK, you will be directed to
the login page automatically.
© 2008~2009 SYM. All rights reserved.
Page 20
User Manual UWMS‐01 Version 2.0
IV. Troubleshooting
Description
Power LED is not lit
PPP LED is not lit
Status LED is not blinking
Can’t access UWMS‐01’s GUI
Can’t access Device’s GUI
Device is not registered
automatically in Network
Device Status table
Heartbeat is not generated
Can’t change the Device’s
Static IP address
Try this
Make sure the power cord is properly connected to the UWMS‐01.
Make sure the power adapter is properly connected to a functioning
power outlet. If the power is supplied by other Devices using the DC
power cord, make sure the Device is properly powered.
Make sure the modem’s received signal strength is greater than ‐85
dBm. If the signal is not sufficient, place the UWMS‐01 in a place where
it has better signal strength, e.g., by a window. If you are using the
supplied dipole antenna, couple the antenna port with an external donor
antenna of the system to which the UWMS‐01 is connected.
Make sure the Power LED is lit. Turn off the UWMS‐01 and turn it back
on.
Make sure the Ethernet cable is connected securely both to the UWMS‐
01 and your laptop. The small green status light next to the Ethernet
port should be lit. Make sure you changed your laptop’s TCP/IP settings
to Obtain an IP Address Automatically. When you type in the URL, do
not forget the port number at the end, e.g., http://192.168.1.100:8888.
When your laptop is operated on battery, some laptops automatically
disable the LAN card. Enable the LAN card when operating on battery.
You should turn off Wi‐Fi since this may cause the LAN to disable. You
can also try the following: (1) disconnect the LAN cable and connect it
again; (2) disable Local Area Connection and then enable it again; or (3)
reboot the UWMS‐01.
Make sure the distance between the UWMS‐01 and the Device is less
than 328 feet (100 meters). If the problem persists, contact the Device
manufacturer.
Check the device’s heartbeat setting. Heartbeat must be turned on.
Turn off the UWMS‐01 and turn it back on. Turn off the Device and turn
it back on. Check the Device’s IP settings.
Make sure the Device has latitude and longitude information stored
correctly. Make sure Device’s heartbeat is turned on. Make sure PPP
LED is lit in solid green.
If the Device won’t allow you to change its IP address and has the DHCP
client feature, make sure the UWMS‐01’s DHCP is on. Contact the
Device manufacturer.
© 2008~2009 SYM. All rights reserved.
Page 21
User Manual UWMS‐01 Version 2.0
V. Technical Specifications
A. Electrical Specifications
Power Supply
„ AC Power Supply
Input: AC 100 ~ 240V 50/60Hz
„ DC Power Supply (Direct DC Supply)
Input: 12V±1V, 2A
„ Power Consumption
12[W] Max
Ethernet
Standard Compatibility: IEEE802.3 CSMA/CD
„ Ethernet Link: MDI/MDI‐X, auto‐crossover
„ Data Rate: 10/100MBps Auto Negotiation, half/full‐duplex
„ Address Database Size: 1024 MAC addresses
„ Switching Capacity: 1Gbps
„
B.
Environmental Specifications
„
„
C.
Operating Temperature: 14 ~ 158°F
Operating Humidity: 0 ~ 90%
Mechanical Specifications
„
„
Dimension (inches): W: 10.55 D: 6.22 H: 1.77
Weight (lbs): 3.2
© 2008~2009 SYM. All rights reserved.
Page 22
User Manual UWMS‐01 Version 2.0
VI. Safety and Warranty Information
A. General Precaution
There are several simple guidelines to operating the UWMS‐01 properly and safely.
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Avoid exposing the UWMS‐01 to extreme temperatures, either hot or cold. The UWMS‐01 is for
indoor use only.
Keep the unit in a clean, well‐ventilated and dust‐free place.
Avoid exposing the UWMS‐01 to rain or liquid spills. If the UWMS‐01 gets wet, immediately turn
off the power and dry the unit completely.
Use only the power supply adapter that comes with the unit. Replacement power supply
adapters may be ordered from SYM Technology.
Treat the UWMS‐01 with care. Avoid dropping, throwing, or sitting on it. Rough treatment may
damage the unit and void the warranty.
Do not attempt to disassemble your unit. If the warranty seal has been broken, the warranty is
no longer valid.
Any changes or modifications to your unit not expressly approved in this document could void
your warranty.
B. Radio Frequency (RF) Energy
The UWMS‐01 is a radio transmitter and receiver, just like your mobile phone. When it is turned on, it
receives and transmits radio frequency (RF) signals. The RF power level can range from 0.006 watt to
0.25 watt. Please avoid working in close proximity (within 20 cm) to the UWMS‐01.
For more information about RF exposure, visit the FCC Web site at
www.fcc.gov
C. Specific Absorption Rates (SAR)
The SAR is a value that corresponds to the relative amount of RF energy absorbed in the head of a user
of a wireless device. SAR values at or below the federal standard of 1.6 W/kg are considered safe for
use by the public.
Although the UWMS‐01 is to be mounted or placed at a specific location, take caution not to have
prolonged exposure to the UWMS‐01 in close proximity.
D. FCC Notice
This system complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this system may not cause harmful interference, and (2) this system must accept any
interference received, including interference that may cause undesirable operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
© 2008~2009 SYM. All rights reserved.
Page 23
User Manual UWMS‐01 Version 2.0
Note: This system has been tested and found to comply with the limits for a Class B digital device,
pursuant to the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This system generates uses and can radiate RF energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this unit does cause
harmful interference to radio or television reception, which can be determined by turning the unit off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
ƒ
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna
Increase the separation between the unit and receiver
Connect the unit to an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician.
E. Manufacturer’s Limited Warranty
SYM Technology, Inc. (“SYM”) offers a limited warranty that the enclosed unit (“Product”) will be free
from defects in material or workmanship as follows:
FIVE (5) YEAR LIMITED WARRANTY: For a period of five (5) years from the date of original purchase, SYM
will, at its option, either repair or replace a defective Product (with new or rebuilt parts/replacement).
LIMITED WARRANTY ON REPAIRED/REPLACED PRODUCTS: After SYM repairs or replaces the Product,
the repaired or replaced Product shall be covered by warranty for the remaining time of the original
warranty period or for ninety (90) days from the date of repair, whichever is longer. Repair or
replacement may include the use of functionally equivalent reconditioned units. Replaced faulty parts or
components will become the property of SYM Technology.
This limited warranty does not cover and is void with respect to the following: (i) Products which have
been improperly installed, maintained, modified, or repaired; (ii) Products which have been subject to
outdoor use, misuse, physical damage, abnormal use or operation, improper handling or storage,
exposure to fire, water, excessive moisture or extreme temperature; (iii) Products operated outside
published maximum ratings; (iv) Products on which warranty seals or Product serial numbers have been
removed, broken, or altered; (v) cost of installation, set up, removal or reinstallation; (vi) signal
reception problems or network problems (unless caused by defect in material or workmanship); (vii)
damage as a result of fire, flood, power surge, lightening, acts of God or other acts which are not the
fault of SYM and which the Product is not specified to tolerate; (viii) any Products which have been
opened, modified, or repaired by anyone other than SYM or a SYM authorized service center.
REPAIR OR REPLACEMENT, AS HEREINABOVE PROVIDED, IS YOUR SOLE AND EXCLUSIVE REMEDY FOR
BREACH OF THE LIMITED WARRANTY. SYM SHALL HAVE NO LIABLITY FOR ANY INCIDENTAL OR
CONESQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF SALES, OR
LOSS OF USE OF THE PRODUCT. SYM MAKES NO OTHER EXPRESS WARRANTY, EITHER WRITTEN OR
© 2008~2009 SYM. All rights reserved.
Page 24
User Manual UWMS‐01 Version 2.0
ORAL, WITH RESPECT TO THE PRODUCTS. THE DURATION OF IMPLIED WARRANTIES, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED
TO THE DURATION OF THIS EXPRESS WARRANTY.
SYM Technology, Inc.
Attention: Customer Service
Phone: (626) 394‐6630
Email: support@symtehcnology.com
VII. Glossary
BTS
DAS
DHCP
ESN
GPS
GUI
MDN
NOC
PPP
RSSI
UWMS
Base Transceiver System
Distributed Antenna System
Dynamic Host Configuration Protocol
Electronic Serial Number
Global Positioning System
Graphic User Interface
Modem Directory Number
Network Operation Center
Point to Point Protocol
Received Signal Strength (RSS)
Universal Wireless Monitoring System
© 2008~2009 SYM. All rights reserved.
Page 25

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 25
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:0218375f-3963-44cb-93d4-3149ea4447fc
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2009:01:22 23:55:34-08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:01:22 23:55:34-08:00
Document ID                     : uuid:098f7f7b-7fe3-4427-8add-72ffd4c7daf5
Format                          : application/pdf
Creator                         : Vincent
Title                           : Microsoft Word - SYM_UWMS-01_User Manual_V.2.0_Jan.2009
Author                          : Vincent
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W74UWMS-01

Navigation menu