SZ PGST PN602 Burglar alarm control panel User Manual

SZ PGST CO., LTD Burglar alarm control panel

User Manual

Manual InstructionsManual InstructionsApp StoreAndroidScan   here download and install APPQR code
WIFI Alarm System 01Content                      1、Technical Parameters..................................................................................................       1.1 Dimension drawing...............................................................................................2、Features....................................................................................................................3、Daily Operaion Nouns.................................................................................................4、Panel Indicator Lights.................................................................................................5、Side Panel Jacks and Function keys..............................................................................6、Buzzer.......................................................................................................................7、Use Beginning............................................................................................................8、Parameter Initialization..............................................................................................9、Mobile APP Distribution Network/ Unbinding with Alarm Host......................................      9.1  Mobile APP Distribution Network with Host...........................................................      9.2  Mobile APP unbinding with host.............................................................................10、Add or Delete Remotes and Detectors........................................................................      10.1  How to add........................................................................................................      10.2  Control the host into learning state by S1 key........................................................      10.3  Control the host into learning state or delete remotes/detectors by SMS................      10.4  Control the host into learning state or delete remotes/detectors by mobile APP.....                 10.4.1  Mobile APP controls the host to learn remotes..........................................                 10.4.2  Mobile APP controls the host to learn detectors.........................................                 10.4.3  Mobile APP controls the host to delete remotes learnt...............................                 10.4.4  Mobile APP controls the host to delete detectors learnt.............................11、Learning with External Wireless Siren.........................................................................      11.1  By S1 button.......................................................................................................      11.2  By mobile APP control.........................................................................................12、Parameter Setting and Query.....................................................................................      12.1  APP query and parameter setting: function switch setting, alarm phone setting,                  entry delay setting..............................................................................................      12.2  Remote SMS setting of parameter........................................................................      12.3  Remote SMS setting of host name........................................................................334567788991010101111111112141415151516161719
WIFI Alarm System02       12.4  Remote SMS query of parameter set....................................................................                 12.4.1  Query system setting................................................................................                 12.4.2  Query system setting2..............................................................................                 12.4.3  Query alarm phone number setting...........................................................                 12.4.4  Query various delay setting......................................................................                 12.4.5  Query ON/OFF setting.............................................................................                 12.4.6  Query the quantity of remotes and detectors learnt...................................13、User daily operation.................................................................................................       13.1  Arm...................................................................................................................       13.2  Stay Arm............................................................................................................       13.3  Disarm..............................................................................................................       13.4  SOS...................................................................................................................       13.5  Modify SMS to control user password..................................................................       13.6  SMS operation feedbacks...................................................................................14、Alarm and Remote Monitoring...................................................................................       14.1  SMS alarm.........................................................................................................       14.2  Mobile APP receiving alarm process....................................................................       14.3  Netwoking monitoring centre alarm....................................................................       14.4  Remote monitoring............................................................................................                      14.4.1  Host automatically calls preset phone numbers when alarm.......................                 14.4.2  Preset phone numbers remotely call host..................................................15、Packing List..............................................................................................................                      191919202020202121222324242425252526262626271. Technical ParametersWIFI Alarm System 031.1 Dimension drawingARM90.5 mm80.5 mm28.60 mmUSB 5V S2 S1LEARNMICRO-SIMWIFI/INITHost frontHost side WIFI Alarm System02       12.4  Remote SMS query of parameter set....................................................................                 12.4.1  Query system setting................................................................................                 12.4.2  Query system setting2..............................................................................                 12.4.3  Query alarm phone number setting...........................................................                 12.4.4  Query various delay setting......................................................................                 12.4.5  Query ON/OFF setting.............................................................................                 12.4.6  Query the quantity of remotes and detectors learnt...................................13、User daily operation.................................................................................................       13.1  Arm...................................................................................................................       13.2  Stay Arm............................................................................................................       13.3  Disarm..............................................................................................................       13.4  SOS...................................................................................................................       13.5  Modify SMS to control user password..................................................................       13.6  SMS operation feedbacks...................................................................................14、Alarm and Remote Monitoring...................................................................................       14.1  SMS alarm.........................................................................................................       14.2  Mobile APP receiving alarm process....................................................................       14.3  Netwoking monitoring centre alarm....................................................................       14.4  Remote monitoring............................................................................................                      14.4.1  Host automatically calls preset phone numbers when alarm.......................                 14.4.2  Preset phone numbers remotely call host..................................................15、Packing List..............................................................................................................                      2222222222222222222222
WIFI Alarm System 05WIFI Alarm System04Built-in powerful performance CPU master based on 32-bit Cortex-M3 core Based on uCOS - III operating system multitasking design, with a great user operation experience.WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice monitoring/center network etc. multi-channel alarm ways, to ensure the alarm performance stable and reliable.Reserve remote GPRS TCP/UDP protocol channel, compatible with multi-alarm center network protocol, convenient for network alarm.Support APP/SMS/center remote control and parameter settings.Friendly APP operating experience and user interface, access to latest equipment working status.GPRS real-time on line to get device’s newly working status, auto alarm in off-line state. Up to 100 storage locations for the learning of remotes and wireless detectorsSupport local button, APP remote learning of remote controllers and wireless detectorsSupport many defense zones name such as of the gate, SOS, bedroom, window, balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc. Support many defense zone types setting such as of entry/exit zone, indoor zone, perimeter zone, 24-hour zone, etc.Support external wireless siren.Up to 5 groups preset alarm phone numbers, SMS on/off and voice on/off can be set respectively.3 groups of breathing lights display the Arm/Disarm/Alarm state of the device, GSM/WIFI working state, clear at first glance.Support timing arm and disarmConvenient external SIM slot design.2. FeaturesARM: set security task (Anti-burglar), make the host into alert state, also known as    Arming, Alert or Booting. Stay Arm:  When users at home, only need to alert entrances or perimeter.Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or shutdown.Trigger: In Arm state, detector detects someone or door is opened, it will trigger the detectors and make alarms.Exit delay: after setting the host to be ARM state, in order to avoid making alarms for the users leaving and passing the Arm zones, delay the alarm time. Entry delay: when users come back and pass the Arm zones, the host will not immediately make alarms, allow users to Disarm the host with some time; the host will make alarms if time out beyond the Disarm. 3. Daily Operation Nouns
WIFI Alarm System 07WIFI Alarm System064. Panel Indicator LightsARM STA1 STA2NOTESFast flash: 0.1s ON,0.1s OFF;  Slow flash: 0.5s ON,0.5s OFF;   Pulse flash: flash every 5s for 0.1s.3 groups of indicators display the Arm/Disarm/Alarm state, GSM signal state, WIFI state and working state.5. Side Panel Jacks and Function keys6. BuzzerNOTESLong ringing: 0.5s sound, 0.5s mute;Short ringing: 50ms sound, 50ms mute;Alarm sound: keep alarm 50ms, 50ms mute.USB 5V S2 S1LEARNMICRO-SIMWIFI/INIT
Inset SIM card: insert standard MICRO SIM card at slot according to the diagrams(should be trimmed with big SIM card); Card inserting is OK when there is a ‘tick’ sound. Power on: inert the main power supply at USB 5V jack to power the host. Booting: at shutdown state, click S1 button then loosen, 3 indicator lights on at the same time, booting OK.Shutdown: at working state, long press S1 until 3 indicators flash at the same time, then off in 0.1s, shutdown.WIFI Alarm System 09WIFI Alarm System087.Use Beginning 9. Mobile APP Distribution Network/     Unbinding with Alarm Host8. Parameter Initialization      Keep pressing S2 button above 10 times, until the three LEDs turn on at the same time, it means initialization successful, the host cold starts. After initialization, all the parameters set already would be back to the factory defaults, and eliminate all the remote controllers and detectors learnt as well as network IP. Host would be stay at off-line state; If need to be online again and recover central network state, you should send out SMS and re-set IP.The users take cautions using such function, generally you can apply if the host parameter was set in a mess or some unknown remotes or detector were learned.  Notes: The following operations are based on  APP; There would be some                 different description with Android APP. iOS 9.1 Mobile APP distribution network with hostEnsure the host and mobile phones in the same WIFI network.Run mobile APP software, login the registered account at the user login interface (new users need to register account number).In the device list interface, press the top right corner "Airlink" button, enter the intelligent configuration interface.Press down S2 button of the host until the WIFI light flashes fast, then release, the host enters into configuration state.Enter the WIFI password, press the "OK" button, WIFI indicator light of the host stops flashing; Configuration is OK.After configuration’s OK, in equipment list interface, the APP will show the MAC address of the host in the list box , a mobile phone can be configured with multiple alarm hosts; select the corresponding MAC address to the host, and you can control the different hostsAs shown in the figures below:
Enter “System Settings” menu.Press "Remote Setting" and enter the remote controller interface, APP would obtain the Quantity of remotes already learnt with the host.Press "Add Devices" button, enter the remotes learning interface.Press the button "Learning”, send the host learning instructions of remotes.Press any key of the remotes to learn, finish the learning, the host sends the APP information of learning success.APP pops up "Learn OK”, finish the learning. APP returns to the interface of remote controller, and obtain again the quantity of remotes already learnt with the host.10.4.1 Query system settingWIFI Alarm System 11WIFI Alarm System109.2 Mobile APP unbinding with hostKeep pressing S2 button of the host five times then release, the WIFI light fast flashes 1 second, the host automatically terminates WIFI binding. In about 10~20s, WIFI light flashes slowly which means unbinding is successful. After removing the binding, APP needs distribution network again to match the alarm host.10.Add or Delete Remotes and Detectors10.1 How to addControl host enters into the learning state: Host can enter the learning state by three ways: S1 button of the host, SMS, and mobile phone APP(More details please check the three points behind).Please trigger the corresponding wireless devices within 20 seconds or press any key of the remotes.Learning results indicate as follows:?       Learning successful: three indicator lights flash 5 times            together, buzzer makes 2 long sounds.?        Already learnt: three indicator lights flash 2 times together,            buzzer makes 2 short sounds.?        No storage location or timeout (learn failure): 3 indicator lights            flash once together, buzzer makes 5 short sounds.10.2 Control the host into learning state by S1 keyFirst keep pressing button to choose the devices to be learnt, then loosen the button, enter learning state. Refer to below tablet:Device to be learnt Keep pressing S1 button to choose the device to be learntLoosen S1 button to enterlearning state of the device10.3 Control the host into learning state or     delete remotes/detectors by SMSBy sending an SMS to the host, control the host into the learning state or delete existing remotes or detectors. Specific methods, see SMS settings part.10.4 Control the host into learning state or delete     remotes/detectors by mobile APP
WIFI Alarm System 13WIFI Alarm System12As shown in the figures below:10.4.2 Mobile APP controls the host to learn detectorsEnter“System Settings" menu.Press "Detector Setting", enter the detector setup interface, APP would obtain the quantity of detectors already learnt with the host.Press the "Add Devices" button to enter the detector coding interface.Press "Detector Name"column, select one name for the detector which is waiting for coding. Press" Zone Mode" column, select the zone type required by corresponding detector. Press the "Learning" to send command to the host.Trigger the detector to finish coding .Then the host sends message to APP to show it's coded successfully.APP pops up “Learn OK”, coding is finished.APP returns to detector setup interface, and obtains again the detectors coded and its quantity learnt with the host. As shown in the figures below:
WIFI Alarm System 15WIFI Alarm System1410.4.3 Mobile APP controls the host to delete remotes learntKeep pressing “Remote Controller” on its setting interface.(In IOS system, press “Delete” symbol)Dialogue window pops up, if user confirm to delete, press “OK”. App sends deleting commands to hostAPP returns to the remote setup interface, then obtains the quantity of remote controllers coded again. If deleted successfully, the quantity of remote controller would be zero.As shown in the figures below:As shown in the figures below:10.4.4 Mobile APP controls the host to delete detectors learntIn detector setup interface, Press detector’s “Deleting”icon in the list coded.Dialogue window pops up, if user confirm to delete, press “OK”. App then sends deleting command of corresponding detector to hostAPP return to detector setup interface, then obtains the quantity of all detectors coded again. The detectors deleted would disappear. 11.Learning With External Wireless Siren11.1 By S1 buttonMake the wireless siren into learning status. Press“S1”button till the two led lights flash at the same time then loose it ,host will continuously emit one-second signal to the siren.11.2 By mobile APP controlThe way of mobile APP controlChoose“Wireless Siren Setting”in“System Settings”menu. Press“Trigger”button in the interface of wireless siren setup,then App sends wireless triggering signal to host if trigger succeed. App shows “Trigger OK”.As shown in the figures below:
WIFI Alarm System1612.Parameter Setting and QueryUser can set or query host parameters by SMS or mobile app12.1 App query and parameter setting: function switch          setting, alarm phone setting, entry delay setting      After setting the desired function in setup interface, press“Finish”button,App sends setting command to the host.After setting up, user return to the setting interface again with updated contentsAs shown in the figures below:12.2 Remote SMS setting of parametersUsers only need to edit SMS with the following format and send to the host SIM number to complete the setting.One setting SMS can obtain multiple setting addresses and contents,but must isolate them with *,head and tail must end with*,each address must be two digital,or may occur unexpected setting results.One setting SMS can not be more than 160 characters.We recommend set one SMS with all needed contents.WIFI Alarm System 17NullNullNullNullSN will roll up with the updating of new softwareonceonceNullNullNullNull,Refer to annotation 4
WIFI Alarm System 19WIFI Alarm System18Note:All examples below with default engineer password “6666”(1) Control host into learning status setting format A,BA is for setting detector name,“0-11” O-others, 1-gate, 2-hall, 3-SOS, 4-bedroom,5-window, 6-balconies, 7- perimeter, 8-smoke, 9-gas, 10-carbon monoxide, 11-water leak. B is for setting defense zone type, “0-11”t, 0- stay arm , 1- out arm , 2 -24-hour zone , 3- close all corresponding defense zones.Example:The detector name is hall and defense zone is out arm,set SMS“ *6666*232,1* ”When host receives this SMS,it will enter learning status and trigger detector within 20s,then host will automatically name this detector “hall”(only valid for out arm).(2) Delete detectorExample:Delete all named”window” detector,set SMS to be“ *6666*245* ”.(3) Auto Arm/Disarm setting format: HHMM,hhmmHHMM is disarm time(hour,minute),hhmm is arm time(hour,minute)Example:Set disarm time is 8:20,arm time is 20:30,turn on auto arm/disarm switch, set SMS  “ *6666*411*420820,2030* ”. (4) Parameter initialization:Reserve all learned remotes and detectors ,      the remaining restore factory settings,set SMS “ *6666*43* ”.xxxxxxxxxxx is  phone number ( up to 19 ), A is alarm voice dialing switch (1- ON , 0 -OFF), B is the alarm SMS switch (1 -ON , 0 -OFF) .Example:Set two alarm phone numbers ,number 13912345678 to receive voice dialing and SMS , number  number 075 581 234 567 only receive voice dialing , then set SMS:  *6666 *5113912345678,1,1*52075581234567,1,0*.(5) Alarm Phone Number Setting format xxxxxxxxxxxA,Baaa,bbb,ccc,ddd is IP address,xxxxxis port number,intermediate must be isolated with commasExample:Set GPRS network server IP address 120.24.237.164, port number is 2001 , then set SMS  *6666*90120,24,237,164,2001* .(6) IP Address Setting Format aaa,bbb,ccc,ddd,xxxxxHost support to name host in(up to 20 characters), prefix alarm messages for easy identification of specific host or alarm location.Set SMS: 1234mz,xx district, building , “1234” is user password, “xx district, building”is the setting name12.3 Remote SMS setting of host name12.4 Remote SMS query of parameters set12.4.1 Query system settingSMS format  *6666*62* SYSTEM set:SN:ENGINEER PASSWORD:USER PASSWORD:GSM CSQ:WIFI RSSI:SMS format *6666*90*SYSTEM set2:APN:GPRS IP:NTP IP:12.4.2 Query system setting 2
WIFI Alarm System 21WIFI Alarm System2012.4.3 Query alarm phone number settingSMS format *6666*51*PHONE set:1:2:3:4:5:REDIAL COUNTER:SMS format: *6666*33*DELAY set:ENTRY:EXIT:SIREN:12.4.4 Query various delay settingSMS format: *6666*46*SWITCH set:ARM/DISARM BEEP:ALARM BEEP:ARM/DISARM SMS:12.4.5 Query ON/OFF settingSMS format: *6666*26*DETECTOR learned:REMOTE:DETECTOR:12.4.6 Query the quantity of remotes and detectors learnt13.User Daily OperationThe user can operate the host at any way as follows:?       Operate by remote controller on site?       Remotely Sending SMS?       Remotely using a mobile phone APP?       Center Remote Control (valid only for GPRS network)13.1 ArmRemote control operation: Press the remote control Out Arm key [    ].SMS Operation: Send SMS 1234bf , “1234” stands for the user's password. The host will reply to the controlling phone with a message saying "Remote Arm success!".APP Operation : In the main menu, press "Arm" icon, then select the delayed arming time (Exit delay),3 seconds later, the device will return to Arm successfully, APP’s middle status icons is updated as Arm.Host Tip: 3 LED lights flash slowly once, and the buzzer makes long beeps twice, the host indicator light starts blinking in turn in the exit delay status,the red LED light will keep on when delay time is over, please leave the scene before the end of the delay. If the "Arm / Disarm SMS notification switch" has been opened in the setting, host will send a message saying "Arm success" to the preset phone.In Arm state, all defense zones are into alert status, at this time once one defense zone is triggered, the control panel generates a local sound and light alarm, and send alarm messages and make phone calls to the pre-set phone numbers , at the same time push the alarm message to phone APP while send alarm information to the network monitoring center.As shown in the figures below:Cancel OK
WIFI Alarm System 23WIFI Alarm System2213.2 Stay ArmRemote control operation: press Arm key on the remote control at home ].SMS Operation: Send SMS 1234zj  , “1234” stands for the user's password. The host will reply to the controlling phone  with a message saying "Stay Arm success!".APP Operation: In the main menu, press the "Stay Arm" icon for 3 seconds, the device will return to stay Arm successfully, APP’s middle state icon is updated as Stay Arm.Host Tip: 3 LED lights flash in turn for 1 second, the buzzer makes short beeps twice, and the red indicator light starts breathing display. If the "Arm / Disarm SMS notification switch" has been open in the setting, the host will send a message saying "Home Arm success" to the preset telephone.[     In home Arm state, only stay arm’s effective defense zone is into alert state, if the zone is triggered at this time, the control panel generates a local sound and light alarm, and send alarm messages and make phone calls to a pre-set alarm phone number, meanwhile push alarm message to the phone APP, and send alarm information to the network control center.As shown in the figures below:13.3 DisarmRemote control operation: Press the [     ] button on the remote control to disarm.SMS Operation: Send SMS 1234cf  , “1234” stands for the user's password. The host will reply to the controlling phone with a message saying "disarm success!"APP Operation: In the main menu, press "Disarm" icon for 3 seconds, the device will return to disarm successfully, APP’s middle state icon is updated as disarm.Host Tip: 3 LEDs flash twice slowly, the buzzer makes a long beep once, after disarm, all alarms would be stopped, the host will be back to normal state. If the "Arm / Disarm SMS notification switch" has been opened in the setting ,the host will send a message saying"disarm success" to the preset phone number.As shown in the figures below:
WIFI Alarm System 25WIFI Alarm System2413.4 SOSRemote control operation: Press the SOS button on the remote control [         ].APP Operation: In the main menu, press the "SOS" icon.Host Tip: 3 LED lights flash quickly 10 times, the buzzer makes 5 short sounds quickly , 3 seconds later, the middle icon of the APP is updated as “SOS” icon, generating a local sound and light alarm, meanwhile send an alarm SMS message or dial the pre-set alarm phone number, meanwhile send alarm information to the network control center.As shown in the figures below:SOS13.5 Modify SMS to control user passwordSMS operation: Send SMS 1234mm5678, “1234” stands for the user's password, “5678” is for the new password, must be four digits.13.6 SMS operation feedbacks<Host’s name>:Remote Operation ResultsCurrent status: Arm / Stay Arm / DisarmPower supply status: main power / backup (backup battery voltage)14.1 SMS Alarm14.Alarm and Remote MonitoringThe host supports multiple alarm types, when the alarm occurs, it would send the corresponding alarm message to the user mobile phone number and push alarm information to the mobile APP through the detector name defined in learning and even send alarm information to network monitoring center while dial the user’s phone number , the user can monitor the scene once the telephone has been got through.The host also supports the following alarm types:?    The host AC power failure (the host AC power fault lasts for 5 seconds, the alarm will         be valid).?    Back-up battery low power (in power fault state, if the backup battery voltage is        lower than 3.45V for 10 seconds, this alarm will be valid?    The main power restore<Host’s English name>:The current alarmCurrent status: Arm / Stay arm / DisarmPower supply status: main power / backup (back-up battery voltage)     When the alarm occurs, the host sends alarm SMS to the preset phone numbers, as follows:14.2 Mobile APP receiving alarm process.      When the alarm occurs, the host push alarm information to the mobile phone then the user enter the main menu of APP, APP’s middle icon status is changed to” red bell” symbol, and APP displays the current alarm type. The user can  choose "alarm message" icon to query for all user operation records and host alarm records by pressing “Alarm Log”.DoorSOS

Navigation menu