SZ PGST PN602 Burglar alarm control panel User Manual

SZ PGST CO., LTD Burglar alarm control panel

User Manual

Download: SZ PGST PN602 Burglar alarm control panel User Manual
Mirror Download [FCC.gov]SZ PGST PN602 Burglar alarm control panel User Manual
Document ID3262827
Application IDZzqU361EyPPMi0SIflhMPA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize298.27kB (3728412 bits)
Date Submitted2017-01-18 00:00:00
Date Available2017-01-18 00:00:00
Creation Date2017-01-16 07:59:49
Producing SoftwareCorel PDF Engine Version 14.0.0.653
Document Lastmod0000-00-00 00:00:00
Document TitlePN-602英文说明书-公司标准版 带二维码V1.0 20161116
Document CreatorCorelDRAW
Document Author: Administrator

Scan QR code here
download and install APP
Android
App Store
Manual Instructions
WIFI Alarm System
01
Content
1、Technical Parameters.................................................................................................. 3
1.1 Dimension drawing............................................................................................... 3
2、Features.................................................................................................................... 4
3、Daily Operaion Nouns................................................................................................. 5
4、Panel Indicator Lights................................................................................................. 6
5、Side Panel Jacks and Function keys.............................................................................. 7
6、Buzzer.
.
..................................................................................................................... 7
7、Use Beginning.
.
.......................................................................................................... 8
8、Parameter Initialization.............................................................................................. 8
9、Mobile APP Distribution Network/ Unbinding with Alarm Host.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..................... 9
9.
1 Mobile APP Distribution Network with Host.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.......................................... 9
9.2 Mobile APP unbinding with host............................................................................. 10
10、Add or Delete Remotes and Detectors.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
....................................................... 10
10.
1 How to add.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
....................................................................................... 10
10.
2 Control the host into learning state by S1 key........................................................ 11
10.3 Control the host into learning state or delete remotes/detectors by SMS.
.
.
.
.
........... 11
10.4 Control the host into learning state or delete remotes/detectors by mobile APP.
.
.
.
. 11
10.4.1 Mobile APP controls the host to learn remotes.
.
.
.
.
..................................... 11
10.4.2 Mobile APP controls the host to learn detectors.
.
.
.
.
.................................... 12
10.4.3 Mobile APP controls the host to delete remotes learnt.
.
............................. 14
10.4.4 Mobile APP controls the host to delete detectors learnt.
.
.
.
.
.
.
...................... 14
11、Learning with External Wireless Siren.
.
.
.
.
.
.
.................................................................. 15
11.
1 By S1 button.
.
..................................................................................................... 15
11.
2 By mobile APP control.
.
.
.
.
.........
.
..........
.
..........
.
..........
.
..........
.
..........
.
..........
.
........ 15
12、Parameter Setting and Query.
.................................................................................... 16
12.
1 APP query and parameter setting: function switch setting, alarm phone setting,
entry delay setting.
.
.
.
.
.
.
....................................................................................... 16
12.
2 Remote SMS setting of parameter.
.
.
.
.
................................................................... 17
12.
3 Remote SMS setting of host name.
.
.
.
.
................................................................... 19
02
WIFI Alarm System
WIFI Alarm System
1. Technical Parameters
12.4 Remote SMS query of parameter set.................................................................... 19
12.4.1 Query system setting................................................................................ 19
12.4.2 Query system setting2.............................................................................. 19
12.4.3 Query alarm phone number setting........................................................... 20
12.4.4 Query various delay setting...................................................................... 20
12.4.5 Query ON/OFF setting............................................................................. 20
12.4.6 Query the quantity of remotes and detectors learnt................................... 20
13、User daily operation................................................................................................. 21
13.1 Arm................................................................................................................... 21
13.2 Stay Arm............................................................................................................ 22
13.3 Disarm.............................................................................................................. 23
13.4 SOS................................................................................................................... 24
1.1 Dimension drawing
13.5 Modify SMS to control user password.................................................................. 24
13.6 SMS operation feedbacks................................................................................... 24
14、Alarm and Remote Monitoring................................................................................... 25
Host front
14.1 SMS alarm......................................................................................................... 25
80.5 mm
14.2 Mobile APP receiving alarm process.................................................................... 25
14.3 Netwoking monitoring centre alarm.................................................................... 26
14.4 Remote monitoring............................................................................................ 26
14.4.1 Host automatically calls preset phone numbers when alarm....................... 26
90.5 mm
14.4.2 Preset phone numbers remotely call host.................................................. 26
15、Packing List.............................................................................................................. 27
ARM
Host side
28.60 mm
USB 5V
S2
S1
WIFI/ INIT LEARN
MICRO-SIM
03
04
WIFI Alarm System
2. Features
WIFI Alarm System
3. Daily Operation Nouns
Built-in powerful performance CPU master based on 32-bit Cortex-M3 core
ARM: set security task (Anti-burglar), make the host into alert state, also known as
Based on uCOS - III operating system multitasking design, with a great user
Arming, Alert or Booting.
operation experience.
WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice
monitoring/center network etc. multi-channel alarm ways, to ensure the alarm
performance stable and reliable.
Stay Arm: When users at home, only need to alert entrances or perimeter.
Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or
shutdown.
Reserve remote GPRS TCP/UDP protocol channel, compatible with multi-alarm
Trigger: In Arm state, detector detects someone or door is opened, it will trigger
center network protocol, convenient for network alarm.
the detectors and make alarms.
Support APP/SMS/center remote control and parameter settings.
Exit delay: after setting the host to be ARM state, in order to avoid making alarms
Friendly APP operating experience and user interface, access to latest equipment
working status.
GPRS real-time on line to get device’s newly working status, auto alarm in off-line
state.
Up to 100 storage locations for the learning of remotes and wireless detectors
Support local button, APP remote learning of remote controllers and wireless
detectors
Support many defense zones name such as of the gate, SOS, bedroom, window,
balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc.
Support many defense zone types setting such as of entry/exit zone, indoor zone,
perimeter zone, 24-hour zone, etc.
Support external wireless siren.
Up to 5 groups preset alarm phone numbers, SMS on/off and voice on/off can be
set respectively.
3 groups of breathing lights display the Arm/Disarm/Alarm state of the device,
GSM/WIFI working state, clear at first glance.
Support timing arm and disarm
Convenient external SIM slot design.
for the users leaving and passing the Arm zones, delay the alarm time.
Entry delay: when users come back and pass the Arm zones, the host will not
immediately make alarms, allow users to Disarm the host with some time; the host
will make alarms if time out beyond the Disarm.
05
06
WIFI Alarm System
4. Panel Indicator Lights
WIFI Alarm System
5. Side Panel Jacks and Function keys
ARM STA1 STA2
USB 5V
S2
MICRO-SIM
6. Buzzer
NOTES
S1
WIFI/ INIT LEARN
3 groups of indicators display the Arm/Disarm/Alarm state, GSM signal state, WIFI state
and working state.
Fast flash: 0.1s ON,0.1s OFF;
Slow flash: 0.5s ON,0.5s OFF;
Pulse flash: flash every 5s for 0.1s.
NOTES
Long ringing: 0.5s sound, 0.5s mute;
Short ringing: 50ms sound, 50ms mute;
Alarm sound: keep alarm 50ms, 50ms mute.
07
08
WIFI Alarm System
7.Use Beginning
Inset SIM card: insert standard MICRO SIM card at slot according to the diagrams
(should be trimmed with big SIM card); Card inserting is OK when there is a ‘tick’
sound.
Power on: inert the main power supply at USB 5V jack to power the host.
Booting: at shutdown state, click S1 button then loosen, 3 indicator lights on at the
same time, booting OK.
WIFI Alarm System
9. Mobile APP Distribution Network/
Unbinding with Alarm Host
Notes: The following operations are based on iOS APP; There would be some
different description with Android APP.
9.1 Mobile APP distribution network with host
Ensure the host and mobile phones in the same WIFI network.
Shutdown: at working state, long press S1 until 3 indicators flash at the same time,
Run mobile APP software, login the registered account at the user login interface
then off in 0.1s, shutdown.
(new users need to register account number).
In the device list interface, press the top right corner "Airlink" button, enter the
intelligent configuration interface.
Press down S2 button of the host until the WIFI light flashes fast, then release, the
8. Parameter Initialization
host enters into configuration state.
Enter the WIFI password, press the "OK" button, WIFI indicator light of the host
Keep pressing S2 button above 10 times, until the three LEDs turn on at the same
stops flashing; Configuration is OK.
time, it means initialization successful, the host cold starts. After initialization, all the
After configuration’s OK, in equipment list interface, the APP will show the MAC
parameters set already would be back to the factory defaults, and eliminate all the
address of the host in the list box , a mobile phone can be configured with
remote controllers and detectors learnt as well as network IP. Host would be stay at offline state; If need to be online again and recover central network state, you should send
out SMS and re-set IP.
The users take cautions using such function, generally you can apply if the host
parameter was set in a mess or some unknown remotes or detector were learned.
multiple alarm hosts; select the corresponding MAC address to the host, and you
can control the different hosts
As shown in the figures below:
09
10
WIFI Alarm System
WIFI Alarm System
10.2 Control the host into learning state by S1 key
First keep pressing button to choose the devices to be learnt, then loosen the button,
enter learning state. Refer to below tablet:
Device to be learnt
9.2 Mobile APP unbinding with host
Keep pressing S2 button of the host five times then release, the WIFI light fast
flashes 1 second, the host automatically terminates WIFI binding. In about 10~20s,
Keep pressing S1 button to
choose the device to be learnt
Loosen S1 button to enter
learning state of the device
10.3 Control the host into learning state or
delete remotes/detectors by SMS
By sending an SMS to the host, control the host into the learning state or delete existing
remotes or detectors. Specific methods, see SMS settings part.
WIFI light flashes slowly which means unbinding is successful. After removing the
binding, APP needs distribution network again to match the alarm host.
10.Add or Delete Remotes and Detectors
10.1 How to add
Control host enters into the learning state: Host can enter the
learning state by three ways: S1 button of the host, SMS, and mobile
phone APP(More details please check the three points behind).
Please trigger the corresponding wireless devices within 20 seconds
or press any key of the remotes.
Learning results indicate as follows:
?
Learning successful: three indicator lights flash 5 times
Already learnt: three indicator lights flash 2 times together,
No storage location or timeout (learn failure): 3 indicator lights
together, buzzer makes 2 long sounds.
buzzer makes 2 short sounds.
flash once together, buzzer makes 5 short sounds.
10.4 Control the host into learning state or delete
remotes/detectors by mobile APP
10.4.1 Query system setting
Enter “System Settings” menu.
Press "Remote Setting" and enter the remote controller interface, APP would
obtain the Quantity of remotes already learnt with the host.
Press "Add Devices" button, enter the remotes learning interface.
Press the button "Learning”, send the host learning instructions of remotes.
Press any key of the remotes to learn, finish the learning, the host sends the APP
information of learning success.
APP pops up "Learn OK”, finish the learning.
APP returns to the interface of remote controller, and obtain again the quantity of
remotes already learnt with the host.
11
12
WIFI Alarm System
As shown in the figures below:
10.4.2 Mobile APP controls the host to learn detectors
Enter“System Settings" menu.
Press "Detector Setting", enter the detector setup interface, APP would obtain the
quantity of detectors already learnt with the host.
Press the "Add Devices" button to enter the detector coding interface.
Press "Detector Name"column, select one name for the detector which is waiting
for coding.
Press" Zone Mode" column, select the zone type required by corresponding
detector.
Press the "Learning" to send command to the host.
Trigger the detector to finish coding .Then the host sends message to APP to show
it's coded successfully.
APP pops up “Learn OK”, coding is finished.
APP returns to detector setup interface, and obtains again the detectors coded and
its quantity learnt with the host.
WIFI Alarm System
As shown in the figures below:
13
14
WIFI Alarm System
WIFI Alarm System
10.4.3 Mobile APP controls the host to delete remotes learnt
Keep pressing “Remote Controller” on its setting interface.(In IOS system, press
“Delete” symbol)
Dialogue window pops up, if user confirm to delete, press “OK”. App sends deleting
commands to host
APP returns to the remote setup interface, then obtains the quantity of remote
controllers coded again. If deleted successfully, the quantity of remote controller
would be zero.
As shown in the figures below:
11.Learning With External Wireless Siren
11.1 By S1 button
Make the wireless siren into learning status. Press“S1”button till the two
led lights flash at the same time then loose it ,host will continuously emit
one-second signal to the siren.
11.2 By mobile APP control
The way of mobile APP control
Choose“Wireless Siren Setting”in“System Settings”menu.
Press“ Trigger ”button in the interface of wireless siren setup,then App
sends wireless triggering signal to host if trigger succeed.
10.4.4 Mobile APP controls the host to delete detectors learnt
In detector setup interface, Press detector’s “Deleting”icon in the list coded.
Dialogue window pops up, if user confirm to delete, press “OK”. App then sends
deleting command of corresponding detector to host
APP return to detector setup interface, then obtains the quantity of all detectors
coded again. The detectors deleted would disappear.
As shown in the figures below:
App shows “Trigger OK”.
As shown in the figures below:
15
16
WIFI Alarm System
12.Parameter Setting and Query
User can set or quer y host parameters by SMS or mobile app
12.1 App query and parameter setting: function switch
setting, alarm phone setting, entry delay setting
WIFI Alarm System
12.2 Remote SMS setting of parameters
Users only need to edit SMS with the following format and send to the host
SIM number to complete the setting.
One setting SMS can obtain multiple setting addresses and contents,but must isolate
them with *,head and tail must end with*,each address must be two digital,or may
occur unexpected setting results.One setting SMS can not be more than 160
characters.We recommend set one SMS with all needed contents.
Null
Null
Null
Null
SN will roll up with
the updating of new
software
After setting the desired function in setup interface, press“Finish”
button,App sends setting command to the host.After setting up, user return
to the setting interface again with updated contents
once
once
As shown in the figures below:
Null
Null,Refer to annotation 4
Null
Null
17
18
WIFI Alarm System
Note:All examples below with default engineer password “6666”
(
1) Control host into learning status setting format A,B
A is for setting detector name,“0-11” O-others, 1-gate, 2-hall, 3-SOS, 4-bedroom,
5-window, 6-balconies, 7- perimeter, 8-smoke, 9-gas, 10-carbon monoxide,
11-water leak. B is for setting defense zone type, “0-11”t, 0- stay arm , 1- out arm ,
WIFI Alarm System
19
(
6) IP Address Setting Format aaa,bbb,ccc,ddd,xxxxx
aaa,bbb,ccc,ddd is IP address,xxxxxis port number,intermediate must be isolated
with commas
Example:
Set GPRS network server IP address 120.24.237.164, port number is 2001 , then set
SMS *6666*90120,24,237,164,2001* .
2 -24-hour zone , 3- close all corresponding defense zones.
Example:
The detector name is hall and defense zone is out arm,set SMS“ *6666*232,1* ”
When host receives this SMS,it will enter learning status and trigger detector within
20s,then host will automatically name this detector “hall”(only valid for out arm).
12.3 Remote SMS setting of host name
Host support to name host in(up to 20 characters), prefix alarm messages for easy
identification of specific host or alarm location.
Set SMS: 1234mz,xx district, building , “1234” is user password, “xx district, building”is
the setting name
(
2) Delete detector
Example:
Delete all named”window” detector,set SMS to be“ *6666*245* ”.
12.4 Remote SMS query of parameters set
(
3) Auto Arm/Disarm setting format: HHMM,hhmm
HHMM is disarm time(hour,minute),hhmm is arm time(hour,minute)
Example:
Set disarm time is 8:20,arm time is 20:30,turn on auto arm/disarm switch, set SMS
“ *6666*411*420820,2030* ”.
(
4) Parameter initialization:Reserve all learned remotes and detectors ,
the remaining restore factory settings,set SMS “ *6666*43* ”.
(
5) Alarm Phone Number Setting format xxxxxxxxxxxA,B
xxxxxxxxxxx is phone number ( up to 19 ), A is alarm voice dialing switch (1- ON , 0 OFF), B is the alarm SMS switch (1 -ON , 0 -OFF) .
Example:
Set two alarm phone numbers ,number 13912345678 to receive voice dialing and
SMS , number number 075 581 234 567 only receive voice dialing , then set SMS:
*6666 *5113912345678,1,1*52075581234567,1,0*.
12.4.1 Query system setting
SMS format *6666*62*
SYSTEM set:
SN:
ENGINEER PASSWORD:
USER PASSWORD:
GSM CSQ:
WIFI RSSI:
12.4.2 Query system setting 2
SMS format *6666*90*
SYSTEM set2:
APN:
GPRS IP:
NTP IP:
20
WIFI Alarm System
12.4.3 Query alarm phone number setting
SMS format *6666*51*
PHONE set:
1:
2:
3:
4:
5:
REDIAL COUNTER:
WIFI Alarm System
13.User Daily Operation
The user can operate the host at any way as follows:
Operate by remote controller on site
Remotely Sending SMS
Remotely using a mobile phone APP
Center Remote Control (valid only for GPRS network)
13.1 Arm
Remote control operation: Press the remote control Out Arm key [ ].
SMS Operation: Send SMS 1234bf , “1234” stands for the user's password. The host
12.4.4 Query various delay setting
will reply to the controlling phone with a message saying "Remote Arm success!".
SMS format: *6666*33*
APP Operation : In the main menu, press "Arm" icon, then select the delayed arming
DELAY set:
ENTRY:
EXIT:
SIREN:
time (Exit delay),3 seconds later, the device will return to Arm successfully, APP’s
middle status icons is updated as Arm.
Host Tip: 3 LED lights flash slowly once, and the buzzer makes long beeps twice, the
host indicator light starts blinking in turn in the exit delay status,the red LED light
will keep on when delay time is over, please leave the scene before the end of the
delay. If the "Arm / Disarm SMS notification switch" has been opened in the setting,
12.4.5 Query ON/OFF setting
host will send a message saying "Arm success" to the preset phone.
SMS format: *6666*46*
SWITCH set:
ARM/DISARM BEEP:
ALARM BEEP:
ARM/DISARM SMS:
In Arm state, all defense zones are into alert status, at this time once one defense zone is triggered, the
control panel generates a local sound and light alarm, and send alarm messages and make phone calls to
the pre-set phone numbers , at the same time push the alarm message to phone APP while send alarm
information to the network monitoring center.
As shown in the figures below:
12.4.6 Query the quantity of remotes and detectors learnt
SMS format:
*6666*26*
DETECTOR learned:
REMOTE:
DETECTOR:
Cancel
OK
21
22
WIFI Alarm System
WIFI Alarm System
13.2 Stay Arm
Remote control operation: press Arm key on the remote control at home [
13.3 Disarm
].
Remote control operation: Press the [
] button on the remote control to disarm.
SMS Operation: Send SMS 1234zj , “1234” stands for the user's password. The host
SMS Operation: Send SMS 1234cf , “1234” stands for the user's password. The host
will reply to the controlling phone with a message saying "Stay Arm success!".
will reply to the controlling phone with a message saying "disarm success!"
APP Operation: In the main menu, press the "Stay Arm" icon for 3 seconds, the
APP Operation: In the main menu, press "Disarm" icon for 3 seconds, the device will
device will return to stay Arm successfully, APP’s middle state icon is updated as Stay
return to disarm successfully, APP’s middle state icon is updated as disarm.
Arm.
Host Tip: 3 LEDs flash twice slowly, the buzzer makes a long beep once, after disarm,
Host Tip: 3 LED lights flash in turn for 1 second, the buzzer makes short beeps twice,
all alarms would be stopped, the host will be back to normal state. If the "Arm /
and the red indicator light starts breathing display. If the "Arm / Disarm SMS
Disarm SMS notification switch" has been opened in the setting ,the host will send a
notification switch" has been open in the setting, the host will send a message
message saying"disarm success" to the preset phone number.
saying "Home Arm success" to the preset telephone.
In home Arm state, only stay arm’s effective defense zone is into alert state, if the zone is triggered at
this time, the control panel generates a local sound and light alarm, and send alarm messages and make
phone calls to a pre-set alarm phone number, meanwhile push alarm message to the phone APP, and
send alarm information to the network control center.
As shown in the figures below:
As shown in the figures below:
23
24
WIFI Alarm System
WIFI Alarm System
13.4 SOS
14.Alarm and Remote Monitoring
Remote control operation: Press the SOS button on the remote control [ SOS ].
APP Operation: In the main menu, press the "SOS" icon.
Host Tip: 3 LED lights flash quickly 10 times, the buzzer makes 5 short sounds quickly ,
3 seconds later, the middle icon of the APP is updated as “SOS” icon, generating a
local sound and light alarm, meanwhile send an alarm SMS message or dial the preset alarm phone number, meanwhile send alarm information to the network control
The host supports multiple alarm types, when the alarm occurs, it would send the
corresponding alarm message to the user mobile phone number and push alarm
information to the mobile APP through the detector name defined in learning and even
send alarm information to network monitoring center while dial the user’s phone
number , the user can monitor the scene once the telephone has been got through.
The host also supports the following alarm types:
center.
The host AC power failure (the host AC power fault lasts for 5 seconds, the alarm will
Back-up battery low power (in power fault state, if the backup battery voltage is
be valid).
As shown in the figures below:
lower than 3.45V for 10 seconds, this alarm will be valid
Door
SOS
The main power restore
14.1 SMS Alarm
When the alarm occurs, the host sends alarm SMS to the preset phone numbers,
as follows:
<Host’s English name>:
The current alarm
Current status: Arm / Stay arm / Disarm
Power supply status: main power / backup (back-up battery voltage)
13.5 Modify SMS to control user password
SMS operation: Send SMS 1234mm5678, “1234” stands for the user's password,
“5678” is for the new password, must be four digits.
14.2 Mobile APP receiving alarm process.
When the alarm occurs, the host push alarm information to the mobile phone
then the user enter the main menu of APP, APP’s middle icon status is changed to”
13.6 SMS operation feedbacks
<Host’s name>:
Remote Operation Results
Current status: Arm / Stay Arm / Disarm
Power supply status: main power / backup (backup battery voltage)
red bell” symbol, and APP displays the current alarm type. The user can choose
"alarm message" icon to query for all user operation records and host alarm records
by pressing “Alarm Log”.
25


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : D:20170116075949Z
Modify Date                     : 0000:01:01 00:00:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : Administrator
Title                           : PN-602英文说明书-公司标准版 带二维码V1.0 20161116
Creation Date--Text             : 
Mod Date--Text                  : 
Producer                        : Corel PDF Engine Version 14.0.0.653
Creator Tool                    : CorelDRAW
Metadata Date                   : 2017:01:16 17:12:10+08:00
Document ID                     : uuid:4ef84196-3ebc-4227-8c76-44f79d52a363
Instance ID                     : uuid:2063e708-739f-46de-b979-11633819d205
Page Count                      : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AIT9-PN602

Navigation menu