SZ PGST PN602 Burglar alarm control panel User Manual
SZ PGST CO., LTD Burglar alarm control panel
SZ PGST >
User Manual
Scan QR code here download and install APP Android App Store Manual Instructions WIFI Alarm System 01 Content 1、Technical Parameters.................................................................................................. 3 1.1 Dimension drawing............................................................................................... 3 2、Features.................................................................................................................... 4 3、Daily Operaion Nouns................................................................................................. 5 4、Panel Indicator Lights................................................................................................. 6 5、Side Panel Jacks and Function keys.............................................................................. 7 6、Buzzer. . ..................................................................................................................... 7 7、Use Beginning. . .......................................................................................................... 8 8、Parameter Initialization.............................................................................................. 8 9、Mobile APP Distribution Network/ Unbinding with Alarm Host. . . . . . . . . . . . . . . . . ..................... 9 9. 1 Mobile APP Distribution Network with Host. . . . . . . . . . . . . . . . . .......................................... 9 9.2 Mobile APP unbinding with host............................................................................. 10 10、Add or Delete Remotes and Detectors. . . . . . . . . . . . . . . . . ....................................................... 10 10. 1 How to add. . . . . . . . . . . . . . . . . ....................................................................................... 10 10. 2 Control the host into learning state by S1 key........................................................ 11 10.3 Control the host into learning state or delete remotes/detectors by SMS. . . . . ........... 11 10.4 Control the host into learning state or delete remotes/detectors by mobile APP. . . . . 11 10.4.1 Mobile APP controls the host to learn remotes. . . . . ..................................... 11 10.4.2 Mobile APP controls the host to learn detectors. . . . . .................................... 12 10.4.3 Mobile APP controls the host to delete remotes learnt. . ............................. 14 10.4.4 Mobile APP controls the host to delete detectors learnt. . . . . . . ...................... 14 11、Learning with External Wireless Siren. . . . . . . .................................................................. 15 11. 1 By S1 button. . ..................................................................................................... 15 11. 2 By mobile APP control. . . . . ......... . .......... . .......... . .......... . .......... . .......... . .......... . ........ 15 12、Parameter Setting and Query. .................................................................................... 16 12. 1 APP query and parameter setting: function switch setting, alarm phone setting, entry delay setting. . . . . . . ....................................................................................... 16 12. 2 Remote SMS setting of parameter. . . . . ................................................................... 17 12. 3 Remote SMS setting of host name. . . . . ................................................................... 19 02 WIFI Alarm System WIFI Alarm System 1. Technical Parameters 12.4 Remote SMS query of parameter set.................................................................... 19 12.4.1 Query system setting................................................................................ 19 12.4.2 Query system setting2.............................................................................. 19 12.4.3 Query alarm phone number setting........................................................... 20 12.4.4 Query various delay setting...................................................................... 20 12.4.5 Query ON/OFF setting............................................................................. 20 12.4.6 Query the quantity of remotes and detectors learnt................................... 20 13、User daily operation................................................................................................. 21 13.1 Arm................................................................................................................... 21 13.2 Stay Arm............................................................................................................ 22 13.3 Disarm.............................................................................................................. 23 13.4 SOS................................................................................................................... 24 1.1 Dimension drawing 13.5 Modify SMS to control user password.................................................................. 24 13.6 SMS operation feedbacks................................................................................... 24 14、Alarm and Remote Monitoring................................................................................... 25 Host front 14.1 SMS alarm......................................................................................................... 25 80.5 mm 14.2 Mobile APP receiving alarm process.................................................................... 25 14.3 Netwoking monitoring centre alarm.................................................................... 26 14.4 Remote monitoring............................................................................................ 26 14.4.1 Host automatically calls preset phone numbers when alarm....................... 26 90.5 mm 14.4.2 Preset phone numbers remotely call host.................................................. 26 15、Packing List.............................................................................................................. 27 ARM Host side 28.60 mm USB 5V S2 S1 WIFI/ INIT LEARN MICRO-SIM 03 04 WIFI Alarm System 2. Features WIFI Alarm System 3. Daily Operation Nouns Built-in powerful performance CPU master based on 32-bit Cortex-M3 core ARM: set security task (Anti-burglar), make the host into alert state, also known as Based on uCOS - III operating system multitasking design, with a great user Arming, Alert or Booting. operation experience. WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice monitoring/center network etc. multi-channel alarm ways, to ensure the alarm performance stable and reliable. Stay Arm: When users at home, only need to alert entrances or perimeter. Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or shutdown. Reserve remote GPRS TCP/UDP protocol channel, compatible with multi-alarm Trigger: In Arm state, detector detects someone or door is opened, it will trigger center network protocol, convenient for network alarm. the detectors and make alarms. Support APP/SMS/center remote control and parameter settings. Exit delay: after setting the host to be ARM state, in order to avoid making alarms Friendly APP operating experience and user interface, access to latest equipment working status. GPRS real-time on line to get device’s newly working status, auto alarm in off-line state. Up to 100 storage locations for the learning of remotes and wireless detectors Support local button, APP remote learning of remote controllers and wireless detectors Support many defense zones name such as of the gate, SOS, bedroom, window, balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc. Support many defense zone types setting such as of entry/exit zone, indoor zone, perimeter zone, 24-hour zone, etc. Support external wireless siren. Up to 5 groups preset alarm phone numbers, SMS on/off and voice on/off can be set respectively. 3 groups of breathing lights display the Arm/Disarm/Alarm state of the device, GSM/WIFI working state, clear at first glance. Support timing arm and disarm Convenient external SIM slot design. for the users leaving and passing the Arm zones, delay the alarm time. Entry delay: when users come back and pass the Arm zones, the host will not immediately make alarms, allow users to Disarm the host with some time; the host will make alarms if time out beyond the Disarm. 05 06 WIFI Alarm System 4. Panel Indicator Lights WIFI Alarm System 5. Side Panel Jacks and Function keys ARM STA1 STA2 USB 5V S2 MICRO-SIM 6. Buzzer NOTES S1 WIFI/ INIT LEARN 3 groups of indicators display the Arm/Disarm/Alarm state, GSM signal state, WIFI state and working state. Fast flash: 0.1s ON,0.1s OFF; Slow flash: 0.5s ON,0.5s OFF; Pulse flash: flash every 5s for 0.1s. NOTES Long ringing: 0.5s sound, 0.5s mute; Short ringing: 50ms sound, 50ms mute; Alarm sound: keep alarm 50ms, 50ms mute. 07 08 WIFI Alarm System 7.Use Beginning Inset SIM card: insert standard MICRO SIM card at slot according to the diagrams (should be trimmed with big SIM card); Card inserting is OK when there is a ‘tick’ sound. Power on: inert the main power supply at USB 5V jack to power the host. Booting: at shutdown state, click S1 button then loosen, 3 indicator lights on at the same time, booting OK. WIFI Alarm System 9. Mobile APP Distribution Network/ Unbinding with Alarm Host Notes: The following operations are based on iOS APP; There would be some different description with Android APP. 9.1 Mobile APP distribution network with host Ensure the host and mobile phones in the same WIFI network. Shutdown: at working state, long press S1 until 3 indicators flash at the same time, Run mobile APP software, login the registered account at the user login interface then off in 0.1s, shutdown. (new users need to register account number). In the device list interface, press the top right corner "Airlink" button, enter the intelligent configuration interface. Press down S2 button of the host until the WIFI light flashes fast, then release, the 8. Parameter Initialization host enters into configuration state. Enter the WIFI password, press the "OK" button, WIFI indicator light of the host Keep pressing S2 button above 10 times, until the three LEDs turn on at the same stops flashing; Configuration is OK. time, it means initialization successful, the host cold starts. After initialization, all the After configuration’s OK, in equipment list interface, the APP will show the MAC parameters set already would be back to the factory defaults, and eliminate all the address of the host in the list box , a mobile phone can be configured with remote controllers and detectors learnt as well as network IP. Host would be stay at offline state; If need to be online again and recover central network state, you should send out SMS and re-set IP. The users take cautions using such function, generally you can apply if the host parameter was set in a mess or some unknown remotes or detector were learned. multiple alarm hosts; select the corresponding MAC address to the host, and you can control the different hosts As shown in the figures below: 09 10 WIFI Alarm System WIFI Alarm System 10.2 Control the host into learning state by S1 key First keep pressing button to choose the devices to be learnt, then loosen the button, enter learning state. Refer to below tablet: Device to be learnt 9.2 Mobile APP unbinding with host Keep pressing S2 button of the host five times then release, the WIFI light fast flashes 1 second, the host automatically terminates WIFI binding. In about 10~20s, Keep pressing S1 button to choose the device to be learnt Loosen S1 button to enter learning state of the device 10.3 Control the host into learning state or delete remotes/detectors by SMS By sending an SMS to the host, control the host into the learning state or delete existing remotes or detectors. Specific methods, see SMS settings part. WIFI light flashes slowly which means unbinding is successful. After removing the binding, APP needs distribution network again to match the alarm host. 10.Add or Delete Remotes and Detectors 10.1 How to add Control host enters into the learning state: Host can enter the learning state by three ways: S1 button of the host, SMS, and mobile phone APP(More details please check the three points behind). Please trigger the corresponding wireless devices within 20 seconds or press any key of the remotes. Learning results indicate as follows: ? Learning successful: three indicator lights flash 5 times Already learnt: three indicator lights flash 2 times together, No storage location or timeout (learn failure): 3 indicator lights together, buzzer makes 2 long sounds. buzzer makes 2 short sounds. flash once together, buzzer makes 5 short sounds. 10.4 Control the host into learning state or delete remotes/detectors by mobile APP 10.4.1 Query system setting Enter “System Settings” menu. Press "Remote Setting" and enter the remote controller interface, APP would obtain the Quantity of remotes already learnt with the host. Press "Add Devices" button, enter the remotes learning interface. Press the button "Learning”, send the host learning instructions of remotes. Press any key of the remotes to learn, finish the learning, the host sends the APP information of learning success. APP pops up "Learn OK”, finish the learning. APP returns to the interface of remote controller, and obtain again the quantity of remotes already learnt with the host. 11 12 WIFI Alarm System As shown in the figures below: 10.4.2 Mobile APP controls the host to learn detectors Enter“System Settings" menu. Press "Detector Setting", enter the detector setup interface, APP would obtain the quantity of detectors already learnt with the host. Press the "Add Devices" button to enter the detector coding interface. Press "Detector Name"column, select one name for the detector which is waiting for coding. Press" Zone Mode" column, select the zone type required by corresponding detector. Press the "Learning" to send command to the host. Trigger the detector to finish coding .Then the host sends message to APP to show it's coded successfully. APP pops up “Learn OK”, coding is finished. APP returns to detector setup interface, and obtains again the detectors coded and its quantity learnt with the host. WIFI Alarm System As shown in the figures below: 13 14 WIFI Alarm System WIFI Alarm System 10.4.3 Mobile APP controls the host to delete remotes learnt Keep pressing “Remote Controller” on its setting interface.(In IOS system, press “Delete” symbol) Dialogue window pops up, if user confirm to delete, press “OK”. App sends deleting commands to host APP returns to the remote setup interface, then obtains the quantity of remote controllers coded again. If deleted successfully, the quantity of remote controller would be zero. As shown in the figures below: 11.Learning With External Wireless Siren 11.1 By S1 button Make the wireless siren into learning status. Press“S1”button till the two led lights flash at the same time then loose it ,host will continuously emit one-second signal to the siren. 11.2 By mobile APP control The way of mobile APP control Choose“Wireless Siren Setting”in“System Settings”menu. Press“ Trigger ”button in the interface of wireless siren setup,then App sends wireless triggering signal to host if trigger succeed. 10.4.4 Mobile APP controls the host to delete detectors learnt In detector setup interface, Press detector’s “Deleting”icon in the list coded. Dialogue window pops up, if user confirm to delete, press “OK”. App then sends deleting command of corresponding detector to host APP return to detector setup interface, then obtains the quantity of all detectors coded again. The detectors deleted would disappear. As shown in the figures below: App shows “Trigger OK”. As shown in the figures below: 15 16 WIFI Alarm System 12.Parameter Setting and Query User can set or quer y host parameters by SMS or mobile app 12.1 App query and parameter setting: function switch setting, alarm phone setting, entry delay setting WIFI Alarm System 12.2 Remote SMS setting of parameters Users only need to edit SMS with the following format and send to the host SIM number to complete the setting. One setting SMS can obtain multiple setting addresses and contents,but must isolate them with *,head and tail must end with*,each address must be two digital,or may occur unexpected setting results.One setting SMS can not be more than 160 characters.We recommend set one SMS with all needed contents. Null Null Null Null SN will roll up with the updating of new software After setting the desired function in setup interface, press“Finish” button,App sends setting command to the host.After setting up, user return to the setting interface again with updated contents once once As shown in the figures below: Null Null,Refer to annotation 4 Null Null 17 18 WIFI Alarm System Note:All examples below with default engineer password “6666” ( 1) Control host into learning status setting format A,B A is for setting detector name,“0-11” O-others, 1-gate, 2-hall, 3-SOS, 4-bedroom, 5-window, 6-balconies, 7- perimeter, 8-smoke, 9-gas, 10-carbon monoxide, 11-water leak. B is for setting defense zone type, “0-11”t, 0- stay arm , 1- out arm , WIFI Alarm System 19 ( 6) IP Address Setting Format aaa,bbb,ccc,ddd,xxxxx aaa,bbb,ccc,ddd is IP address,xxxxxis port number,intermediate must be isolated with commas Example: Set GPRS network server IP address 120.24.237.164, port number is 2001 , then set SMS *6666*90120,24,237,164,2001* . 2 -24-hour zone , 3- close all corresponding defense zones. Example: The detector name is hall and defense zone is out arm,set SMS“ *6666*232,1* ” When host receives this SMS,it will enter learning status and trigger detector within 20s,then host will automatically name this detector “hall”(only valid for out arm). 12.3 Remote SMS setting of host name Host support to name host in(up to 20 characters), prefix alarm messages for easy identification of specific host or alarm location. Set SMS: 1234mz,xx district, building , “1234” is user password, “xx district, building”is the setting name ( 2) Delete detector Example: Delete all named”window” detector,set SMS to be“ *6666*245* ”. 12.4 Remote SMS query of parameters set ( 3) Auto Arm/Disarm setting format: HHMM,hhmm HHMM is disarm time(hour,minute),hhmm is arm time(hour,minute) Example: Set disarm time is 8:20,arm time is 20:30,turn on auto arm/disarm switch, set SMS “ *6666*411*420820,2030* ”. ( 4) Parameter initialization:Reserve all learned remotes and detectors , the remaining restore factory settings,set SMS “ *6666*43* ”. ( 5) Alarm Phone Number Setting format xxxxxxxxxxxA,B xxxxxxxxxxx is phone number ( up to 19 ), A is alarm voice dialing switch (1- ON , 0 OFF), B is the alarm SMS switch (1 -ON , 0 -OFF) . Example: Set two alarm phone numbers ,number 13912345678 to receive voice dialing and SMS , number number 075 581 234 567 only receive voice dialing , then set SMS: *6666 *5113912345678,1,1*52075581234567,1,0*. 12.4.1 Query system setting SMS format *6666*62* SYSTEM set: SN: ENGINEER PASSWORD: USER PASSWORD: GSM CSQ: WIFI RSSI: 12.4.2 Query system setting 2 SMS format *6666*90* SYSTEM set2: APN: GPRS IP: NTP IP: 20 WIFI Alarm System 12.4.3 Query alarm phone number setting SMS format *6666*51* PHONE set: 1: 2: 3: 4: 5: REDIAL COUNTER: WIFI Alarm System 13.User Daily Operation The user can operate the host at any way as follows: Operate by remote controller on site Remotely Sending SMS Remotely using a mobile phone APP Center Remote Control (valid only for GPRS network) 13.1 Arm Remote control operation: Press the remote control Out Arm key [ ]. SMS Operation: Send SMS 1234bf , “1234” stands for the user's password. The host 12.4.4 Query various delay setting will reply to the controlling phone with a message saying "Remote Arm success!". SMS format: *6666*33* APP Operation : In the main menu, press "Arm" icon, then select the delayed arming DELAY set: ENTRY: EXIT: SIREN: time (Exit delay),3 seconds later, the device will return to Arm successfully, APP’s middle status icons is updated as Arm. Host Tip: 3 LED lights flash slowly once, and the buzzer makes long beeps twice, the host indicator light starts blinking in turn in the exit delay status,the red LED light will keep on when delay time is over, please leave the scene before the end of the delay. If the "Arm / Disarm SMS notification switch" has been opened in the setting, 12.4.5 Query ON/OFF setting host will send a message saying "Arm success" to the preset phone. SMS format: *6666*46* SWITCH set: ARM/DISARM BEEP: ALARM BEEP: ARM/DISARM SMS: In Arm state, all defense zones are into alert status, at this time once one defense zone is triggered, the control panel generates a local sound and light alarm, and send alarm messages and make phone calls to the pre-set phone numbers , at the same time push the alarm message to phone APP while send alarm information to the network monitoring center. As shown in the figures below: 12.4.6 Query the quantity of remotes and detectors learnt SMS format: *6666*26* DETECTOR learned: REMOTE: DETECTOR: Cancel OK 21 22 WIFI Alarm System WIFI Alarm System 13.2 Stay Arm Remote control operation: press Arm key on the remote control at home [ 13.3 Disarm ]. Remote control operation: Press the [ ] button on the remote control to disarm. SMS Operation: Send SMS 1234zj , “1234” stands for the user's password. The host SMS Operation: Send SMS 1234cf , “1234” stands for the user's password. The host will reply to the controlling phone with a message saying "Stay Arm success!". will reply to the controlling phone with a message saying "disarm success!" APP Operation: In the main menu, press the "Stay Arm" icon for 3 seconds, the APP Operation: In the main menu, press "Disarm" icon for 3 seconds, the device will device will return to stay Arm successfully, APP’s middle state icon is updated as Stay return to disarm successfully, APP’s middle state icon is updated as disarm. Arm. Host Tip: 3 LEDs flash twice slowly, the buzzer makes a long beep once, after disarm, Host Tip: 3 LED lights flash in turn for 1 second, the buzzer makes short beeps twice, all alarms would be stopped, the host will be back to normal state. If the "Arm / and the red indicator light starts breathing display. If the "Arm / Disarm SMS Disarm SMS notification switch" has been opened in the setting ,the host will send a notification switch" has been open in the setting, the host will send a message message saying"disarm success" to the preset phone number. saying "Home Arm success" to the preset telephone. In home Arm state, only stay arm’s effective defense zone is into alert state, if the zone is triggered at this time, the control panel generates a local sound and light alarm, and send alarm messages and make phone calls to a pre-set alarm phone number, meanwhile push alarm message to the phone APP, and send alarm information to the network control center. As shown in the figures below: As shown in the figures below: 23 24 WIFI Alarm System WIFI Alarm System 13.4 SOS 14.Alarm and Remote Monitoring Remote control operation: Press the SOS button on the remote control [ SOS ]. APP Operation: In the main menu, press the "SOS" icon. Host Tip: 3 LED lights flash quickly 10 times, the buzzer makes 5 short sounds quickly , 3 seconds later, the middle icon of the APP is updated as “SOS” icon, generating a local sound and light alarm, meanwhile send an alarm SMS message or dial the preset alarm phone number, meanwhile send alarm information to the network control The host supports multiple alarm types, when the alarm occurs, it would send the corresponding alarm message to the user mobile phone number and push alarm information to the mobile APP through the detector name defined in learning and even send alarm information to network monitoring center while dial the user’s phone number , the user can monitor the scene once the telephone has been got through. The host also supports the following alarm types: center. The host AC power failure (the host AC power fault lasts for 5 seconds, the alarm will Back-up battery low power (in power fault state, if the backup battery voltage is be valid). As shown in the figures below: lower than 3.45V for 10 seconds, this alarm will be valid Door SOS The main power restore 14.1 SMS Alarm When the alarm occurs, the host sends alarm SMS to the preset phone numbers, as follows: <Host’s English name>: The current alarm Current status: Arm / Stay arm / Disarm Power supply status: main power / backup (back-up battery voltage) 13.5 Modify SMS to control user password SMS operation: Send SMS 1234mm5678, “1234” stands for the user's password, “5678” is for the new password, must be four digits. 14.2 Mobile APP receiving alarm process. When the alarm occurs, the host push alarm information to the mobile phone then the user enter the main menu of APP, APP’s middle icon status is changed to” 13.6 SMS operation feedbacks <Host’s name>: Remote Operation Results Current status: Arm / Stay Arm / Disarm Power supply status: main power / backup (backup battery voltage) red bell” symbol, and APP displays the current alarm type. The user can choose "alarm message" icon to query for all user operation records and host alarm records by pressing “Alarm Log”. 25
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Administrator Create Date : D:20170116075949Z Modify Date : 0000:01:01 00:00:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Administrator Title : PN-602英文说明书-公司标准版 带二维码V1.0 20161116 Creation Date--Text : Mod Date--Text : Producer : Corel PDF Engine Version 14.0.0.653 Creator Tool : CorelDRAW Metadata Date : 2017:01:16 17:12:10+08:00 Document ID : uuid:4ef84196-3ebc-4227-8c76-44f79d52a363 Instance ID : uuid:2063e708-739f-46de-b979-11633819d205 Page Count : 15EXIF Metadata provided by EXIF.tools