Sagem Wireless MA110 MA110 User Manual DOC MA

Sagem Wireless MA110 DOC MA

Contents

Users Manual

      MorphoAccessTM 100 SeriesUser Guide    Produced by SAGEM Défense Sécurité  Copyright ©2006 SAGEM Défense Sécurité www.sagem.com   MorphoAccessTM 100 Series User Guide  May 2006SK-0000038480-02
 2  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
   Table of content  INTRODUCTION 6 INTERFACES PRESENTATION 7 MAN-MACHINE INTERFACE 7 ELECTRICAL INTERFACES 8 SETTING UP THE TERMINAL IP ADDRESS 9 ACCESS CONTROL PRESENTATION 10 IDENTIFICATION - AUTHENTICATION 10 “HIT OR NO HIT” RESULT COMMUNICATION 12 “PROXY” MODE 13 CONFIGURING A “CONNECTED” MORPHOACCESS 14 INTRODUCTION 14 NETWORK FACTORY SETTINGS 15 CONFIGURING A STANDALONE MORPHOACCESS 16 “USB” KEY ADMINISTRATION 16 PRINCIPLE 17 CHANGING A PARAMETER 18 CONFIGURATION INTERFACE 18 CONFIGURATION ORGANIZATION 18 “CONFIGURATION TOOL” 19 UPGRADING THE FIRMWARE 20 ACCESS CONTROL BY IDENTIFICATION 21 ACCESS CONTROL BY AUTHENTICATION (MA120 / MA110 ONLY) 22 CONTACTLESS AUTHENTICATION WITH TEMPLATES ON A CONTACTLESS CARD 23   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  3
 CONTACTLESS AUTHENTICATION WITH TEMPLATES ON LOCAL DATABASE 24 CONTACTLESS AUTHENTICATION BASED ON CARD MODE 25 BYPASSING THE BIOMETRIC CONTROL IN AUTHENTICATION 26 MERGED MODE 27 MORPHOACCESS 220 320 COMPATIBILITY 28 PROXY MODE 29 RECOGNITION MODE SYNTHESIS 30 SETTING UP RECOGNITION MODE 31 TWO ATTEMPTS MODE 31 PARAMETERS 31 SETTING UP MATCHING PARAMETERS 32 RELAY ACTIVATION 33 LED IN ACTIVATION 34 LOG FILE 35 REMOTE MESSAGES 36 PRESENTATION 36 SUPPORTED PROTOCOLS 36 TAMPER SWITCH MANAGEMENT 37 ALARM ACTIVATION 37 EXAMPLES 38 MAN MACHINE INTERFACE 39 CONVENTION 39 IDENTIFICATION – WAITING FOR A FINGER 39 AUTHENTICATION – WAITING FOR A BADGE 39 FUSION - WAITING FOR A FINGER OR A BADGE 40 CONTROL OK 40 CONTROL FAILED 40 NO DATABASE OR EMPTY DATABASE 40 BIOMETRIC ACQUISITION, BAD PLACEMENT 41 USB KEY CAN BE REMOVED 41 SENSOR FAILED 41 4  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 NETWORK PARAMETERS 42 SECTION [BOOT PROTO] 42 SECTION [PARAMETERS] 42 TERMINAL INFORMATION 43 SECTION [INFO] (READ ONLY) 43 ADMINISTRATION PARAMETERS 44 SECTION [REMOTE MANAGEMENT TCP] 44 SECTION [TERMINAL] 44 ANNEX: CONTACTLESS MODES TABLE 45 ANNEX: REQUIRED TAGS ON CONTACTLESS CARD 46 FAQ 47 TERMINAL IP ADDRESS IS UNKNOWN OR TERMINAL IS NOT REACHABLE 47 SENSOR IS OFF 47 TERMINAL RETURNS ERRATIC ANSWERS TO PING REQUESTS 47 BIBLIOGRAPHY 48    SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  5
 IINNTTRROODDUUCCTTIIOONN  Congratulations for choosing the SAGEM MorphoAccess™ 1XX Automatic Fingerprint Recognition Terminal.  MorphoAccess™ provides an innovative and effective solution for access control or time and attendance applications using Fingerprint Verification or/ and Identification. Among a range of alternative biometric techniques, the use of finger imaging has significant advantages: each finger constitutes an unalterable physical signature which develops before birth and is preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins. The MorphoAccess™ terminal integrates SAGEM image processing and feature matching algorithms. This technology is based on lessons learned during 20 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records. We believe you will find the SAGEM MorphoAccess™ fast, accurate, easy to use and suitable for physical access control or time and attendance. To ensure the most effective use of your SAGEM MorphoAccess™, we recommend that you read this User Guide totally.  6  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 IINNTTEERRFFAACCEESS  PPRREESSEENNTTAATTIIOONN  MMaann--mmaacchhiinnee  iinntteerrffaaccee  The MorphoAccess™ 1XX offers a simple and ergonomic man-machine interface dedicated to access control based on fingerprint recognition:   A high quality optical scanner to capture fingerprints (1).   A multicolor led (8 colors) (2).   A multi-toned buzzer (3).  A MifareTM contactless reader on MA12X, to read reference templates from a contactless card (4).                        SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  7
 EElleeccttrriiccaall  iinntteerrffaacceess  The terminal offers multiple interfaces dedicated to administration and control information:   A multiplexed Wiegand / Dataclock / RS485 output (5).   Two LED IN inputs to improve integration in an access control system (6).   A relay to directly command an access (7).   A tamper switch (8).  An Ethernet interface (LAN 10 Mbps), allowing remote management through TCP and sending control result through UDP (9).   A USB Host port dedicated to local configuration (10).                     The  MA1XX Installation Guide describes precisely each interface and connection procedure. 8  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 SSEETTTTIINNGG  UUPP  TTHHEE  TTEERRMMIINNAALL  IIPP  AADDDDRREESSSS  The MorphoAccess™ can run in stand alone mode but a TCP/IP connection is required to download records in the terminal and to configure its recognition mode. It is possible to specify standard TCP parameters: terminal network address, network gateway and mask. These parameters can be set using a USB mass storage key. The complete procedure is described in section Configuring a “standalone” MA1XX. Once connected on the network, the MorphoAccess™ can be configured using (for example) the.Configuration Tool.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  9
 AACCCCEESSSS  CCOONNTTRROOLL  PPRREESSEENNTTAATTIIOONN  IIddeennttiiffiiccaattiioonn  --  aauutthheennttiiccaattiioonn  The MorphoAccess™ works according two biometric recognition modes: identification or authentication. Both identification and authentication can be activated (fusion mode). Identification The captured fingerprint is matched against a database – 1 vs. N. Minutiae are stored in terminal local database. The terminal can store 500 users (2 fingers per user) in its local database. In this mode the sensor will be always switched on, waiting for a finger. The captured fingerprint is matched against the whole database.   Internal database Users Templates 45641    45648 … 35631 … 12544             If the user is matched access is granted. If the user is not recognized access is refused. See section Access Control By Identification. 10  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 Authentication The captured fingerprint is matched against a reference template – 1 vs. 1. In authentication, user minutiae can be stored on a contactless card. It is also possible to store minutiae in terminal local database.    Contactless card containing:   ID   Biometrics           If the user is matched access is granted. If the user is not recognized access is refused. See section Access Control By Authentication.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  11
 ““HHiitt  oorr  NNoo  HHiitt””  rreessuulltt  ccoommmmuunniiccaattiioonn  If access is granted (the user has been recognized) the led lights green and the buzzer emits a high-pitched “beep”. If access is denied (the user has not been recognized) the led lights red and the buzzer emits a low-pitched “beep”.     Control result:  RS485  Wiegand  Dataclock  UDP      Various messages or interfaces can be activated to send the control result: Relay After a successful control the MorphoAccess™ relay may be activated during a given period. Wiegand Id Emission The ID of the recognized user can be sent though the Wiegand output. The format of the frame may be user defined. Dataclock Id Emission The ID of the recognized user can be sent though the Dataclock output. Udp Id Emission The ID of the recognized user can be sent though the Ethernet link using UDP. The administrator may set the port. RS485 Control information can be sent through RS485. Local Diary (log) A local file will store biometric logs. 12  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 ““PPrrooxxyy””  mmooddee  Proxy Mode is not strictly speaking a recognition mode. In this mode, the MorphoAccess™ works as “a slave” waiting for external orders such as: Identification Verification Relay activation Read data on a contactless card. …   Proxy orders:   Identification   Verification   Relay activation    Read card   … TCP IP          Section  Remote Management gives more information about remote management. Please refer to MA100 Series Host System Interface for a complete description of TCP orders possibilites.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  13
 CCOONNFFIIGGUURRIINNGG  AA  ““CCOONNNNEECCTTEEDD””  MMOORRPPHHOOAACCCCEESSSS  IInnttrroodduuccttiioonn  A PC (typically a station with MEMSTM) connected to a MorphoAccess™ can manage the terminal. Available remote operations are: Biometric template addition, Control settings modification, Configuration reading, Local database deletion, Record deletion, Control diary downloading, Firmware upgrade.     TCP IP   Remote management :  Change mode  Add template  Get configuration  …       The MorphoAccess™ works as a server waiting for PC request. The PC will send biometric templates to the terminal and manage the local database. Please refer to MA100 Series Host System Interface for a complete description of TCP administration. This document explains how to create a database and store biometric records in this base. 14  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 NNeettwwoorrkk  ffaaccttoorryy  sseettttiinnggss  By default the terminal IP address is 134.1.32.214. This address can be changed through Ethernet or with a USB mass storage key. The default server port is 11010.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  15
 CCOONNFFIIGGUURRIINNGG  AA  SSTTAANNDDAALLOONNEE  MMOORRPPHHOOAACCCCEESSSS  ““UUSSBB””  kkeeyy  aaddmmiinniissttrraattiioonn  MA100 series have no keyboard, no screen. However it is possible to change TCP/IP parameters without connecting the terminal on a network. This operation only requires a standard USB Mass Storage Key (FAT16). A dedicated PC application, USB Network Configuration Tool, allows writing these new parameters on the key.   Please refer to MA100 Series USB Network Tool User Guide. 16  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 PPrriinncciippllee  This feature is available to change network parameters (IP address, mask and gateway). Store a file on a USB Key The administrator creates a configuration file on a PC using the USB Network Configuration Tool. This configuration file contains new network parameters. This file must be stored on a USB Mass Storage Key.   Configuration File:  network parameters       Apply changes on a “stand alone” MorphoAccess The lower protection of the MorphoAccess must be removed to give access to the USB Host Interface of the terminal. The terminal must be powered on. When the USB key is inserted in the MorphoAccess USB interface, the configuration file is read: Ethernet parameters are applied.  Configuration File:  network parameters        At the end of the process a low-pitched “beep” indicates that the key can be removed. Please refer to USB Network Configuration Tool User Guide for more information about this procedure.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  17
 CCHHAANNGGIINNGG  AA  PPAARRAAMMEETTEERR  CCoonnffiigguurraattiioonn  iinntteerrffaaccee  Terminal parameters are stored in files. These files can be retrieved and modified through TCP/IP using ILV commands. For more information about remote management please refer to MA100 Series Host System Interface. CCoonnffiigguurraattiioonn  oorrggaanniizzaattiioonn  The terminal contains four files:  app.cfg.  adm.cfg.  bio.cfg.  net.cfg The  app.cfg file contains the application settings, adm.cfg contains administration parameters, bio.cfg the biometric sensor settings and net.cfg Ethernet parameters. Parameter path has the following structure file_name/section/parameter. For example the relay activation is driven by the app/relay/enabled parameter. 18  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 ““CCoonnffiigguurraattiioonn  ttooooll””  The Configuration Tool allows changing these parameters. This program is an illustration of utilization of the TCP API. Please refer to Configuration Tool User Guide for more information about this program.    SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  19
 UUPPGGRRAADDIINNGG  TTHHEE  FFIIRRMMWWAARREE  It is possible to upgrade your MorphoAccess™ firmware. Two packages type are available. One dedicated to terminal system, another one dedicated to biometric library. Use the MA1XX Downloader to upgrade your terminal system. Use the MA1XX BioLoader to upgrade your terminal biometric library. Please refer to the MA100 Series Upgrade Tools User Guide for more information about upgrade procedures. 20  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 AACCCCEESSSS  CCOONNTTRROOLL  BBYY  IIDDEENNTTIIFFIICCAATTIIOONN  Access control by identification app/bio ctrl/identification  1To configure MorphoAccess™ terminal in this mode, set the parameter app/bio ctrl/identification at 1. After starting the MorphoAccess™ terminal waits for fingerprint detection in identification mode. If the identification is successful, the terminal triggers the access or returns the corresponding ID to central security controller. The ID can be sent through various interfaces. Please refer to MA100 Series Remote Messages Specification for a complete description of “hit” and “no hit” messages. A relay can also be activated. Once the person's identification is done, the terminal automatically loops back and waits for a new finger. At least one fingerprint must be stored in the local database. The terminal can store 500 users with 2 fingerprints each. If the terminal is running in identification mode with an empty database, the sensor is off and the led flashes “yellow”. Set app/bio ctrl/identification at 0 to disable the sensor (Proxy Mode).   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  21
 AACCCCEESSSS  CCOONNTTRROOLL  BBYY  AAUUTTHHEENNTTIICCAATTIIOONN  ((MMAA112200  //  MMAA111100  OONNLLYY))  Various recognition modes can be applied depending on the templates localization, the required security level. These modes can be combined with a local identification (fusion mode). Following modes are available: Contactless authentication with templates on card: Captured fingerprints are matched against templates read on the card (PK). Identifier and fingerprints must be stored on the card. Contactless authentication with templates on local database: Captured fingerprints are matched against templates read from the local database. Only the identifier is required on the card. Contactless authentication based on card mode: Depending on the card mode either templates are read on the card or the control can be bypassed (visitor mode). The “card mode” tag must be stored on the card. Please refer to MA100 Series Contactless Card Specification for a complete description of card structure and access mode. It is also possible to skip the biometric control: in this case the terminal acts as a badge reader. 22  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 CCoonnttaaccttlleessss  aauutthheennttiiccaattiioonn  wwiitthh  tteemmppllaatteess  oonn  aa  ccoonnttaaccttlleessss  ccaarrdd  Contactless authentication with templates (PK) on card app/bio ctrl/authent PK contactless  1MorphoAccessTM 110 or 120 can work in contactless authentication mode: the user presents its card, the terminal reads the reference biometric templates (PK) on the card and launches a biometric control based on the read templates. In this case the card will contain the user identifier and biometric templates: no local database is required. To change the parameter value use the Set Registry Key ILV command, or directly the Configuration Tool. To enable this mode set app/bio ctrl/authent PK contactless to 1. To disable this mode set app/bio ctrl/authent PK contactless to 0. Required tags on card  ID  CARD MODE  PK1  PK2  PIN  BIOPIN authent PK contactless  Yes No  Yes Yes No No Card structure is described in MA100 Series Contactless Card Specification.    SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  23
 CCoonnttaaccttlleessss  aauutthheennttiiccaattiioonn  wwiitthh  tteemmppllaatteess  oonn  llooccaall  ddaattaabbaassee  Contactless authentication with templates on local database app/bio ctrl/authent ID contactless  1The user identifier can be used as an index in the local database of the MorphoAccess™: in this case the reference biometric templates are stored in the local database. The content of the “ID” tag must match with the user identifier in the terminal database. To enable this mode set app/bio ctrl/authent ID contactless to 1. To disable this mode set app/bio ctrl/authent ID contactless to 0. Required tags on card  ID  CARD MODE  PK1  PK2  PIN  BIOPIN authent ID contactless  Yes  No No No No No Card structure is described in MA100 Series Contactless Card Specification. 24  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 CCoonnttaaccttlleessss  aauutthheennttiiccaattiioonn  bbaasseedd  oonn  ccaarrdd  mmooddee  Contactless authentication with card mode app/bio ctrl/authent card mode  1In this mode the card “decides” on the control progress. The “CARD MODE” tag is required. This tag can take two values: •  PKS [0x02]: user identifier, template 1 and template 2 are required on the card. Biometric authentication is triggered with biometric templates. •  ID_ONLY [0x01]: only the user identifier is required. There is no biometric control, the control is immediately positive. This feature is usefull for visitor requiring an access without enrollment. But it is still possible to store templates on the card. To enable this mode set app/bio ctrl/authent card mode to 1. To disable this mode set app/bio ctrl/authent card mode to 0. Required tags on card If CARD MODE tag value is ID_ONLY.  ID  CARD MODE  PK1  PK2  PIN  BIOPIN authent card mode (ID_ONLY) Yes Yes No No No No  If CARD MODE tag value is PKS.  ID  CARD MODE  PK1  PK2  PIN  BIOPIN authent card mode (PKS)  Yes Yes Yes Yes No No Card structure is described in MA100 Series Contactless Card Specification.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  25
 BByyppaassssiinngg  tthhee  bbiioommeettrriicc  ccoonnttrrooll  iinn  aauutthheennttiiccaattiioonn  In this mode only the user id is required on the card. This flag must be combined with an authentication mode. Activating this flag means that the biometric verification is bypassed.  When combined “authent ID contactless” the MorphoAccess™ verifies that the identifier read on the card is present on the local database before granting the access. Disabling biometric control, but ID must be present in the local database app/bio ctrl/bypass authentication  1app/bio ctrl/authent ID contactless  1When combined “authent PK contactless” the MorphoAccess™ allways authorizes the access: the MorphoAccess™ works as a “simple” MifareTM or iCLASS™ card reader. Disabling biometric control, access is allways granted app/bio ctrl/bypass authentication  1app/bio ctrl/authent PK contactless  1To bypass biometric control set app/bio ctrl/bypass authentication to 1. To enable biometric control set app/bio ctrl/bypass authentication to 0. Required tags on card  ID  CARD MODE  PK1  PK2  PIN  BIOPIN bypass authentication    Yes No No No No No  26  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 MMeerrggeedd  mmooddee  This mode is the fusion of identification mode and contactless authentication without database mode. So this mode allows: Running an identification if user places his finger (operation identical to identification mode), Running a contactless authentication if user places his contactless card (operation identical to contactless authentication without database mode). If there is no database contactless card presentation is still possible. This mode is activated by enabling one contactless mode and identification. Merged mode app/bio ctrl/identification  1And app/bio ctrl/authent PK contactless app/bio ctrl/authent card mode 0 or 10 or 1Required tag on card depends on the authentication mode.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  27
 MMoorrpphhooAAcccceessss  222200  332200  ccoommppaattiibbiilliittyy  These tables present parameter equivalence between MA320/220 family and MA120 family. Merged mode (/cfg/Maccess/Admin/mode 5 on 220 and 320) is activated when app/bio ctrl/identification is set to 1. MA 220 320  MA 120 Contactless authentication with ID on card, template in local database /cfg/Maccess/Admin/mode 4 app/bio ctrl/authent ID contactless 1 Contactless authentication: Card mode /cfg/Maccess/Contactless/without DB mode 0 /cfg/Maccess/Admin/mode 3 or app/bio ctrl/authent card mode 1  /cfg/Maccess/Admin/mode 5 (merged mode) app/bio ctrl/identification 1 Contactless authentication: Biometric verification /cfg/Maccess/Contactless/without DB mode 2 /cfg/Maccess/Admin/mode 3 or app/bio ctrl/authent PK contactless 1/cfg/Maccess/Admin/mode 5 (merged mode) app/bio ctrl/identification 1 Contactless authentication: ID “only”, no biometric verification /cfg/Maccess/Contactless/without DB mode 1 /cfg/Maccess/Admin/mode 3 or app/bio ctrl/authent PK contactless 1app/bio ctrl/bypass authentication 1 /cfg/Maccess/Admin/mode 5 (merged mode) app/bio ctrl/identification 1  28  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 PPRROOXXYY  MMOODDEE  This mode allows controlling the MorphoAccess™ remotely (the link is Ethernet) using a set of biometric and databasing management function interface access commands. Identification and authentication must be disabled. It means that all control must be turned off: the terminal becomes a “slave”. Proxy mode app/bio ctrl/identification  0app/bio ctrl/authent PK contactless  0app/bio ctrl/authent ID contactless  0app/bio ctrl/authent card mode  0Please refer to refer to MA100 Series Host System Interface: this document explains how to manage a terminal on a TCP network.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  29
 RREECCOOGGNNIITTIIOONN  MMOODDEE  SSYYNNTTHHEESSIISS  The MA100 series operating mode is driven by: •  The authentication or identification mode required: Card Only, Card + Biometric, Biometric only •  Who defined the operating mode: Card or Terminal    Mode defined by Card app/bio ctrl/authent card mode 1 Mode defined by Terminal app/bio ctrl/authent card mode 0 Operating mode    ID in card bypass authentication 1 authent ID contactless 1 Check ID on terminal Authentication Card only  (MA120/MA110) ID in card Card Mode Tag = ID_ONLY ID in card bypass authentication 1 authent PK contactless 1 No ID check on terminal ID and BIO in card bypass authentication 0 authent PK contactless 1 Authentication Card  + Biometric  (MA120/MA110) ID and BIO in Card Card Mode Tag = PKS ID on card and BIO in terminal bypass authentication 0 authent ID contactless 1 Identification Biometric only  (MA1xx)  ID and BIO in termina identification 1  30  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 SSEETTTTIINNGG  UUPP  RREECCOOGGNNIITTIIOONN  MMOODDEE  TTwwoo  aatttteemmppttss  mmooddee  If the recognition fails, it is possible to give a “second chance” to the user. In identification mode if a bad finger is presented the user has 5 seconds to present a finger again. The result is sent if this period expires or if the user presents a finger again. In authentication mode, if the user presents a bad finger, he can replace his finger without presenting his card again. The result is sent only after this second attempt. It is possible to set the finger presentation timeout and to deactivate this “two attempts mode”. PPaarraammeetteerrss  This mode can be configured using the Configuration Tool for example. By default the two attempts mode is activated. Setting up the number of attempts app/bio ctrl/nb attempts  1 (only one attempts)2 (two attempts mode) The period between two attempts in identification (two attempts mode) can be modified. Setting up the identification timeout app/bio ctrl/identification timeout  5 (1-60)  In authentication mode a finger presentation period can be defined. Setting up the authentication timeout app/bio ctrl/authent timeout  (1-60)    SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  31
 SSEETTTTIINNGG  UUPP  MMAATTCCHHIINNGG  PPAARRAAMMEETTEERRSS  Setting up matching threshold bio/bio ctrl/matching th  1-10The performances of a biometric system are characterized by two quantities, the False Non Match Rate - FNMR - (Also called False Reject Rate) and the False Match Rate - FMR - (Also called False Acceptance Rate). Different trade-off are possible between FNMR and FMR depending on the security level targeted by the access control system. When convenience is the most important factor the FNMR must be low and conversely if security is more important then the FMR has to be minimized. Different tuning are proposed in the MorphoAccess terminal depending on the security level targeted by the system. The table below details the different possibilities. This parameter can be set to values from 1 to 10. This parameter specifies how tight the matching threshold is. Threshold scoring values are identified hereafter 1  Very few persons rejected  FAR < 1% 2    FAR < 0.3% 3  Recommended value (default value) FAR < 0.1% 4    FAR < 0.03% 5  Intermediate threshold  FAR < 0.01% 6    FAR < 0.001% 7   FAR < 0.0001% 8    FAR < 0.00001% 9  Very high threshold (few false acceptances) Secure application FAR < 0.0000001% 10  High threshold for test purpose only  There are very few false recognitions, and many rejections 32  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 RREELLAAYY  AACCTTIIVVAATTIIOONN  If the control is successful, a relay may be activated to directly control a door. This installation type offers a low security level. Relay activation app/relay/enabled  1 The relay aperture time can be defined and is set by default to 3 seconds (i.e. 300). Relay aperture time in 10 ms app/relay/aperture time in 10 ms  300( 50 to 60000 )   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  33
 LLEEDD  IINN  AACCTTIIVVAATTIIOONN  Use this signal to wait a controller “ACK” before granting the access.       User ID  LED1 to GND: Access authorized. LED2 to GND: Access refused.   1- If the user is recognized the MA1XX sends the user identifier to the controller. 2 - The MA1XX waits for a GND signal on LED1 or LED2. A timeout can be defined. 3 - The controller checks the user rights. 4 - The controller sets LED1 to GND to authorize the access or sets LED2 to GND to forbid the access. 5 – The control restarts only when LED1 and LED2 are set to “1” again. This feature improves integration in an access control system (ACS). The ACS through LED IN signals validates result of biometric matching. LED IN mode activation app/led IN/enabled  1When the ACS validates the control a timeout must be specified: it defines the time during which the MorphoAccess™ will wait for an acknowledgement signal from the ACS through LED IN signals LED IN “acknowledgement timeout” in 10 ms app/led IN/controller ack timeout  0 to 268435455 During the time LED1 or LED2 is set to GND the control DOES NOT RESTART. 34  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 LLOOGG  FFIILLEE  MorphoAccessTM is logging its activities app/log file/enabled  1The MorphoAccess™ can log its biometric activities. It stores the result of the command, the date and time, the matching mark, the execution time, and the ID of the user. It is possible to download the diary file. For more information on this feature, refer to the MA100 Series Host System Interface.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  35
 RREEMMOOTTEE  MMEESSSSAAGGEESS  PPrreesseennttaattiioonn  The MorphoAccessTM terminal can send status messages in real time to a controller by different means and through different protocols. This information, called Remote Messages can be used, for instance to display on an external screen the result of a biometric operation, the name or the ID of the person identified…depending on the role of the controller in the system.             UDPRS485 The MA100 Series Remote Messages Specification describes the different solutions offered by the MorphoAccess™ to dialog with a controller, and how to make use of them. SSuuppppoorrtteedd  PPrroottooccoollss  The terminal can send messages about the biometric operations performed by the MorphoAccess™ to a controller through the following protocols: Wiegand Dataclock RS485 Ethernet (UDP) 36  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 TTAAMMPPEERR  SSWWIITTCCHH  MMAANNAAGGEEMMEENNTT  AAllaarrmm  aaccttiivvaattiioonn  The MorphoAccess™ can detect that the back cover has been removed. The device can send an alarm to the central controller in case of intrusion. It can also play a sound alarm whilst sending the alarm.                Sound alarm Alarm message •UDP •RS485 •Wiegand •Dataclock To send an alarm on an output (UDP, Wiegand, Dataclock or RS485), the corresponding interface must be activated otherwise no alarm will be sent. Because Wiegand, Dataclock, and RS485 are multiplexed on the same lines, only one of these protocols shall be enabled at one time, else priority is given to Wiegand, then Dataclock, then RS485. These keys are: app/send ID wiegand/enabled app/send ID dataclock/enabled app/send ID RS485/enabled app/send ID UDP/enabled   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  37
 Tamper switch management feature is configured by setting the key app/tamper alarm/level to an appropriate value. Tamper Alarm Level app/tamper alarm/level 0 No Alarm. 1 Send Alarm (No Sound Alarm). 2 Send Alarm and Activates Buzzer (Sound Alarm) 0-2The key app/failure ID/alarm ID defines the value of the alarm ID to send in Wiegand or Dataclock. This ID permits to distinguish between an user ID and a error ID. Tamper Alarm Level app/failure ID/alarm ID  0- 65535 In Wiegand and Dataclock the alarm ID is sent like other Failure IDs, see the documentation MA100 Series Remote Messages Specification for a description of the packet format in UDP and RS-485. EExxaammpplleess  Example 1: Send an alarm ID (62221) in Wiegand, and play sound warning, in case of intrusion detection. To send an alarm in Wiegand, the key app/send ID wiegand/enabled must be set to 1.and the key app/tamper alarm/level must be set to 2 (alarm and buzzer.) The key app/failure ID/alarm ID must be set to 62221 to link the intrusion event to this identifier. Example 2: Send an alarm in UDP quietly in case of intrusion detection. To send an alarm in UDP, the key app/send ID UDP/enabled must be set to 1. Then the key app/tamper alarm/level must be set to 1 (quiet alarm.)  38  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 MMAANN  MMAACCHHIINNEE  IINNTTEERRFFAACCEE  CCoonnvveennttiioonn  Intermittent “Pulse”: led is 1 second OFF, 0.05 second ON. For example: Intermittent blue “Pulse”   Fast “Pulse”: led flashes quickly. The rhythm is the same than when a hard drive works. Fast orange “Pulse”   Slow intermittent “Pulse”. led is 1 second OFF, 1 second ON. For example: Slow intermittent red “Pulse”.  IIddeennttiiffiiccaattiioonn  ––  wwaaiittiinngg  ffoorr  aa  ffiinnggeerr  Sensor  ON  Led  OFF   AAuutthheennttiiccaattiioonn  ––  wwaaiittiinngg  ffoorr  aa  bbaaddggee  Sensor  OFF  Led  Intermittent blue “Pulse”      SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  39
 FFuussiioonn  --  wwaaiittiinngg  ffoorr  aa  ffiinnggeerr  oorr  aa  bbaaddggee  Sensor  ON  Led  Intermittent blue “Pulse”   CCoonnttrrooll  OOKK  Sensor  ON  Led  Green 1 second   Buzzer  ON 0.1 second - High-pitched   CCoonnttrrooll  ffaaiilleedd  Sensor  ON  Led  Red 1second   Buzzer  ON 0.7 second - Low-pitched   NNoo  ddaattaabbaassee  oorr  eemmppttyy  ddaattaabbaassee  Sensor  OFF  Led  Slow intermittent orange “Pulse”.   40  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 BBiioommeettrriicc  aaccqquuiissiittiioonn,,  bbaadd  ppllaacceemmeenntt  Sensor  ON  Led  Fast intermittent orange “Pulse”.   UUSSBB  kkeeyy  ccaann  bbee  rreemmoovveedd  Sensor  - - Led  Fast intermittent blue “Pulse”.   Buzzer  ON 0.7 second - Low-pitched   SSeennssoorr  ffaaiilleedd  Sensor  OFF  Led  Slow intermittent red “Pulse”.     SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  41
 NNEETTWWOORRKK  PPAARRAAMMEETTEERRSS  These parameters can be changed using the Configuration Tool or by implementing ILV commands. Network parameters are stored in a file named “net.cfg”.  A change is applied after rebooting the terminal. SSeeccttiioonn  [[bboooott  pprroottoo]]  DHCP activated 0 NO 1 YES SSeeccttiioonn  [[ppaarraammeetteerrss]]  host name “MA-1234567890” network address “134.1.32.214” by default, static address. network mask “255.255.240.0“by default. default gateway “134.1.6.20“ by default.  42  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 TTEERRMMIINNAALL  IINNFFOORRMMAATTIIOONN  These parameters can be changed using the Configuration Tool or by implementing ILV commands. The “app.cfg” file contains information about your terminal configuration. SSeeccttiioonn  [[iinnffoo]]  ((rreeaadd  oonnllyy))  Type 120: MorphoAccess™ with local database and MifareTM contactless reader 110: MorphoAccess™ with local database and ICLASSTM contactless reader 100: MorphoAccess™ with local database. Minor Software revision (minor) Major Software revision (major) Release Release version.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  43
 AADDMMIINNIISSTTRRAATTIIOONN  PPAARRAAMMEETTEERRSS  The “app.cfg” file contains advanced parameter to modify the host port and the connection mode. This parameter must not be changed. SSeeccttiioonn  [[rreemmoottee  mmaannaaggeemmeenntt  TTCCPP]]  Inactivity timeout Must be set to 0. Port 11010 by default, defines the socket server port. SSeeccttiioonn  [[tteerrmmiinnaall]]  Group Must be set to 255. 44  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 AANNNNEEXX::  CCOONNTTAACCTTLLEESSSS  MMOODDEESS  TTAABBLLEE  Operation Authent card mode Authent PK contactless Authent ID contactless Bypass authentication Authentication with templates in database Read ID on contactless card. Retrieve corresponding templates in database. Biometric authentication using these templates.  Send ID if authentication is successfull. 0 0 1  0 Authentication with templates on card Read ID and templates on contactless card. Biometric authentication using these templates.  Send ID if authentication is successfull. 0  1  0 0 Card mode authentication Read card mode, ID, templates (if required by card mode) on contactless card. If card mode is « ID only », send ID. If card mode is « Authentication with templates on card », biometric authentication using templates read on card, then send ID if authentication is successfull. 1  0 0 0 Authentication with templates in database – biometric control disabled Read ID on contactless card. Check corresponding templates presence in database. Send ID if templates are present. 0 0 1 1 Authentication with templates on card – biometric control disabled Read ID on contactless card. Send ID. 0  1  0  1 Card mode authentication – biometric control disabled Read card mode, ID, templates (if required by card mode) on contactless card. Whatever card mode, send ID. 1 0 0 1   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  45
 AANNNNEEXX::  RREEQQUUIIRREEDD  TTAAGGSS  OONN  CCOONNTTAACCTTLLEESSSS  CCAARRDD  Operation  ID  CARD MODE  PK1  PK2  PIN  BIOPIN Authentication with templates in database  Yes  No No No No No Authentication with templates on card  Yes No  Yes Yes No No Card mode authentication (ID_ONLY)  Yes Yes No No No No Card mode authentication (PKS)  Yes Yes Yes Yes No No Authentication with templates in database – biometric control disabled Yes  No No No No No Authentication with templates on card – biometric control disabled Yes No No No No No Card mode authentication (ID_ONLY) – biometric control disabled Yes Yes No No No No Card mode authentication (PKS) – biometric control disabled Yes Yes Yes Yes No No   46  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 FFAAQQ  TTeerrmmiinnaall  IIPP  aaddddrreessss  iiss  uunnkknnoowwnn  oorr  tteerrmmiinnaall  iiss  nnoott  rreeaacchhaabbllee  Use  USB Network Configuration Tool to set a valid network address in your terminal. See section Configuring a standalone MorphoAccess.SSeennssoorr  iiss  ooffff  Verify that the base contents at least one record. Check that identification is enabled. TTeerrmmiinnaall  rreettuurrnnss  eerrrraattiicc  aannsswweerrss  ttoo  ppiinngg  rreeqquueessttss  Check the subnet mask. Ask to your administrator the right value.   SAGEM Défense Sécurité document. Reproduction and disclosure forbidden  47
 BBIIBBLLIIOOGGRRAAPPHHYY  MA100 Series Installation Guide This document describes terminal electrical interfaces and connection procedures.  MA100 Series Standard Host Interface Specification A complete description of remote management commands.  MA100 Series Remote Messages Specification A description of the MA1XX communication interfaces.  MA100 Series Contactless Card Specification This document describes the MA12X Contactless card feature.  MA100 Series Configuration Tool User Guide Configuration Tool user guide , via Ethernet  MA100 Series USB Network Tool User Guide Configuration Tool user guide , via USB key  MA100 Series Upgrade Tools User Guide Upgrade Tool user guide about firmware upgrading procedures.  MA100 Series Configuration Guide The complete description of terminal configuration files. 48  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden
 Siège social : Le Ponant de Paris 27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE

Navigation menu