Sagem Wireless MA110 MA110 User Manual Installation Guide

Sagem Wireless MA110 Installation Guide

Contents

Installation Guide

   MORPHOACCESSTM  Installation Guide MA1xx  series    MorphoAccessTM 100/110/120  November 2005SK 0000034370 - 01
 2 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  3   CONTENTS  INTRODUCTION 5 SAFETY INSTRUCTIONS  6 GENERAL DESCRIPTION  7 INSTALLATION PROCEDURE  10 STAGE 1 : DRILLING THE CHASSIS MOUNTING HOLES 10 STAGE 2 : CABLE ENTRY HOLE LOCATION AND CHASSIS FIXATION 11 STAGE 3 : CONNECTING THE COVER ASSEMBLY TO THE CHASSIS 12 STAGE 4: CLOSING MORPHOACCESS™ 13 ELECTRICAL INTERFACE  14 TERMINAL BLOCK BOARD WIRING 14 POWER SUPPLY CABLE 16 WIEGAND OUTPUT WIRING 16 DATA CLOCK OUTPUT WIRING 17 COM RS485 SERIAL PORT 17 ETHERNET WIRING 18 OUTPUT RELAY 19 TAMPER SWITCH 19 USER INTERFACE  20 RECOMMENDATIONS 21 APPENDIX 1 - FINGERPRINT PLACEMENT RULES  23 APPENDIX 2 - BIBLIOGRAPHY  24 APPENDIX 3 - DRILLING TEMPLATE  25
 4 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  5 IINNTTRROODDUUCCTTIIOONN  Congratulations for choosing the SAGEM MorphoAccess™1 Automatic Fingerprint Recognition Terminal. MorphoAccess™ provides an innovative and effective solution for access control applications using Fingerprint Verification or/ and Identification. Among a range of alternative biometric techniques, the use of finger imaging has significant advantages : each finger constitutes an unalterable physical signature which develops before birth and is preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins. The MorphoAccess™ terminal integrates SAGEM image processing and feature matching algorithms (MorphoSoft™ and MorphoImaging™). This technology is based on lessons learned during more than 20 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records. We believe you will find the SAGEM MorphoAccess™ fast, accurate, easy to use and suitable for physical access control. The SAGEM  MorphoAccess™ offers the following advantages: •  High quality optical sensor. •  Supports multiple input/output interfaces used in the physical access control industry. •  Local area network interface for easy interaction with other host systems. •  Very compact size for easy installation and integration into your available office space. •  Open architecture, with dedicated applications implemented via MA1xx Software Development Kit.  To ensure the most effective use of your SAGEM MorphoAccess™, we recommend that you read this Installation Guide totally.                                              1 The SAGEM logo and trademark are the property of SAGEM Défense Sécurité. All other trademarks or product names are trademarks or product names of the respective title holders.
 6 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 SSAAFFEETTYY  IINNSSTTRRUUCCTTIIOONNSS  The installation of this product should be made by a qualified service Person and should conform to all local codes. It is strongly recommended to use a class II power supply at 12 V ±5% and 0.5 A. min according with Safety Electrical Low Voltage (SELV). The 12 V power supply cable length should not exceed 5 meters. This product is intended to be installed with a power  supply conformed to EN60950,  in accordance with the NEC Class 2 requirements ; or supplied by a listed EN60950 external Power Unit marked Class 2 , Limited Power source, or LPS and rated 12 V DC, 0.5 A minimum. In case of building to building connection it is recommended to connect 0V to ground. Ground cable must be connected with the terminal block 0V GND.   Europe information’s : SAGEM  hereby declares that the SAGEM  MorphoAccess™ has been tested and found compliant with the below listed standards as required by the EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998) , EN300-330 (1999) and by the low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000).   USA information’s : This equipment has been tested and found compliant with Class B digital device requirements, pursuant to part 15 of the FCC Rules. These requirements are designed to ensure reasonable protection against harmful RF interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may interfere with radio communications. If this equipment interferes with radio or television reception - which can be determined by disconnecting and re-connecting the unit – the user is encouraged to try to correct the interference by one or more of the following measures : •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help.
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  7 GGEENNEERRAALL  DDEESSCCRRIIPPTTIIOONN    Contactless Card reader( depending of the versions)Optical SensorCable entry  Mounting keyholes Tamper switchPower supply cableTrap door Terminal Block
 8 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 MorphoAccess™ supplies :  1 Cover assembly  1 Chassis  1 Trap door   2 screws for cover fixation 1 secured screwdriver Torx 20  1 secured screw for trap door fixation  Qty    1 Cover assembly  1 Chassis
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  9 1 Trap door  2  Screws for cover fixation into the chassis.  1  Secured screw for trap door fixation  1 Secured screwdriver Torx 20   In order to proceed to MorphoAccess installation , you’ll need a standard 2,5mm screwdriver.
 10 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 IINNSSTTAALLLLAATTIIOONN  PPRROOCCEEDDUURREE  SSttaaggee  11  ::  DDrriilllliinngg  tthhee  cchhaassssiiss  mmoouunnttiinngg  hhoolleess   I.  For choice, drill the 4 corners holes (a) for the screws for the mounting keyholes so that the cable entry is in a suitable position for your cabling, using the dimensional drawing above. II.  In case of electric plug connections , MorphoAccess™ terminal may be  installed directly on US or European plugs , with some of the 5 holes (b). So, drill the needed holes. (a) Screw : 4 mm  (b) Screw : 3 mm
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  11 SSttaaggee  22  ::  CCaabbllee  eennttrryy  hhoollee  llooccaattiioonn  aanndd  cchhaassssiiss  ffiixxaattiioonn       I.  Pass the all connecting cables through the 2 cable entry. Be sure during manipulation that power supply from electric source is off.  II.  Fit the screws chassis fixation. The mounting screws must be 4 mm diameter maximum for corner place (a) and 3 mm diameter maximum for other places (b). Small head screws are required.  Cable entryCable entry
 12 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 SSttaaggee  33  ::  CCoonnnneeccttiinngg  tthhee  ccoovveerr  aasssseemmbbllyy  ttoo  tthhee  cchhaassssiiss      I.  Pass all connecting cable into cover entry holes. II.  Put the cover assembly into the chassis hanging III.  Fit the 2 screws chassis fixation , supplied with MorphoAccess™ IV.  Connect cables to terminal blocks (see the detailed instructions in the following sections) Screw chassis fixationScrew chassis fixation( II )
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  13 SSttaaggee  44::  CClloossiinngg  MMoorrpphhooAAcccceessss™™       I.  Push up the trap door  along the cover assembly II.  Fit the M4x20 assembly secured screw ( use screwdriver Torx 20S supplied with MorphoAccess™  )   ( I )( II )
 14 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 EELLEECCTTRRIICCAALL  IINNTTEERRFFAACCEE  TTeerrmmiinnaall  bblloocckk  bbooaarrdd  wwiirriinngg    Power supply sourceUSB master connectorVarious interfaces
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  15  1 2 3 4 5 6 7 8 9 10 11 12 13 14    15 16   Pin 1  TR- / D1  Out  Wiegand D1 or RS485 TX/RX- or CLK Pin 2  TR+ / D0  Out  Wiegand D0 or RS485 TX/RX+ or Data Pin 3  LED1  In  Wiegand LED1 Pin 4  LED2  In  Wiegand LED2 Pin 5  GND    Ground for Wiegand / RS485 / Dataclock Pin 6  Relay C0    Contact Relay  0 Pin 7  Relay C1    Contact Relay  1 Pin 8  TSW0    Tamper switch Contact 0 Pin 9  TSW1    Tamper switch Contact 1 Pin 10  GND    Ground for Ethernet Interface (LAN 10/100 Mbps) Pin 11  RX-    Receive negative Ethernet Pin 12  RX+    Receive positive Ethernet Pin 13  TX-    Transmit negative Ethernet Pin 14  TX+    Transmit positive Ethernet     Pin 15  +12V    Positive 12 Volts , power supply. Pin 16  GND    Ground power supply. USB
 16 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 PPoowweerr  ssuuppppllyy  ccaabbllee  1 2 3 4 5 6 7 8 9 10 11 12 13 14    15 16 Pin 15  +12V    Positive 12 Volts , power supply. Pin 16  GND    Ground power supply.  Power supply : Must be conformed to CEE/EEC EN60950 standard 12 Volts ± 5% (regulated) 0.5 Amp. It could be coming from 12 Volts Wiegand power supply , conforms to the Security Industry Association's Wiegand standard March 1995.  WWiieeggaanndd  oouuttppuutt  wwiirriinngg  1 2 3 4 5 6 7 8 9 10 11 12 13 14    15 16 Pin 1  TR- / D1  Out  Wiegand D1 Pin 2  TR+ / D0  Out  Wiegand D0 Pin 3  LED1  In  Wiegand LED1 ( option ) Pin 4  LED2  In  Wiegand LED2 ( option ) Pin 5  GND    Ground for Wiegand / RS485 / Dataclock  Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible.
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  17 DDaattaa  CClloocckk  oouuttppuutt  wwiirriinngg  1 2 3 4 5  6 7 8 9 10 11 12 13 14    15 16 Pin 1  TR- / D1  Out  Clock Pin 2  TR+ / D0  Out  Data Pin 5  GND    Ground for Wiegand / RS485 / Dataclock  The electrical interface is 5V TTL compatible.  CCOOMM  RRSS448855  sseerriiaall  ppoorrtt  1 2 3 4 5  6 7 8 9 10 11 12 13 14    15 16 Pin 1  TR- / D1  Out  RS485 TX/RX- Pin 2  TR+ / D0  Out  RS485 TX/RX+ Pin 5  GND    Ground for Wiegand / RS485 / Dataclock  For a half-duplex RS485 connection, only Tx/Rx+ , Tx/Rx- and ground reference signals are necessary.  Depending on RS485 network , an impedance adaptation may be required. A 120 Ohms resistor termination may be added to the terminal , by strapping pin 1 and pin 2 of the auxiliary connector.  1 2 3 4 5 6 7 8 9 10  1 2 3 4 5 6 7 8 9 10 11 12 13 14    15 16
 18 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 EEtthheerrnneett  wwiirriinngg  1 2 3 4 5 6 7 8 9 10 11 12 13 14   15 16 Pin 10  GND    Ground for Ethernet Interface (LAN 10/100 Mbps) Pin 11  RX-    Receive negative Ethernet Pin 12  RX+    Receive positive Ethernet Pin 13  TX-    Transmit negative Ethernet Pin 14  TX+    Transmit positive Ethernet  RJ 45 cabling  recommendation :       RJ45 plug pinout is compliant with 10 base T , IEEE802.3 Specification.  Pinout Signals  EIA/TIA T568B color EIA/TIA T568A color Corel L120 color 1  TD(+) Transmit Data Plus (Output)  White Orange  White Green  Grey 2  TD(-) Transmit Data Minus (Output)  Orange Green White 3  RX(+) Receive Data Plus (Input)  White Green  White Orange  Pink 4 No connection  Blue  Blue  Orange 5  No connection  White blue  White blue  Yellow 6  RX(-) Receive Data Minus (Input)  Green Orange Blue 7  Ground protection ( option )  White Brown  White Brown  Purple 8 No connection  Brown  Brown  Brown
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  19 OOuuttppuutt  rreellaayy  1 2 3 4 5 6 7 8 9 10 11 12 13 14    15 16 Pin 6  Relay C0    Contact Relay  0 Pin 7  Relay C1    Contact Relay  1  Relay ratings 1 A at 30 VDC according to the safety extra low voltage requirements (42.4 VAC max, 60 VDC max) independently of the power supply.  TTaammppeerr  sswwiittcchh  1 2 3 4 5 6 7 8 9 10 11 12 13 14   15 16 Pin 8  TSW0    Tamper switch Contact 0 Pin 9  TSW1    Tamper switch Contact 1   Tamper-switch ratings 50 mA at 20 VDC max according to the safety extra low voltage.
 20 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 UUSSEERR  IINNTTEERRFFAACCEE  MorphoAccess™ terminal works upon three principles : Access control with identification, access control with authentication, and proxy mode.  These three principles consist in five functional modes : •  Mode 0 :  Local identification (fingerprint capture) with a local base, MA100 default mode  •  Mode 1 :   Reserved  •  Mode 2 :  Proxy mode; Command sending to the MorphoAccess™  •  Mode 3 :  Authentication (contactless card reading minutiae) and fingerprint capture MA100 and MA120 default mode  •  Mode 4 :  Authentication (contactless card reading ID) and fingerprint capture with a local base  •  Mode 5 :   Modes 0 and 3, merged  •  Mode 6:   Reserved  The MorphoAccess™ 1xx series manage one base of 500 persons with 2 fingers, locally or remotely.
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  21 RReeccoommmmeennddaattiioonnss  AArreeaass  ccoonnttaaiinniinngg  ccoommbbuussttiibblleess  It is strongly recommended that you do not install your SAGEM  MorphoAccess™ in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials. GGeenneerraall  pprreeccaauuttiioonnss  •  Do not attempt to repair your SAGEM  MorphoAccess™ yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty. •  Do not use your SAGEM  MorphoAccess™ in damp areas (swimming pool...). Protect it from water and other liquids. •  Do not expose your SAGEM  MorphoAccess™ to extreme temperatures. •  Use your SAGEM   MorphoAccess™ with original accessories. Attempts to integrate the MorphoAccess™ with unapproved accessories will void your warranty. •  Due to electrostatic discharge, and depending on the environment, synthetic carpet should be avoided in areas where the SAGEM  MorphoAccess™ has been installed. EEtthheerrnneett  ccoonnnneeccttiioonn  It is recommended to use a category 5 shielding cable (120 OHM). It is also strongly recommended to insert a repeater unit every 90 m. Extreme care must be taken while connecting Ethernet wire to the terminal block board since low quality connection may strongly impact Ethernet signal sensibility. It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with Tx+/Tx- and the other twisted-pair wire). DDaattee  //  TTiimmee  ssyynncchhrroonniissaattiioonn  If you except to use the MorphoAccessTM for application requiring high time precision we recommend to synchronize regularly your terminal time with an external clock. The terminal clock has a 40 10-6  ppm time deviation.
 22 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 CClleeaanniinngg  pprreeccaauuttiioonnss  A dry cloth should be used. WWaarrnniinngg  The manufacturer cannot be held responsible if the above recommendations are not followed or if the SAGEM  MorphoAccess™ is incorrectly used.                       Biometrics Terminals Hot-Line To Access this service, please call us in order to get your login. Please send email rather call the hot-line.  Email: hotline.biometrics@sagem.com Tel : + 33 1 34 30 39 19 (Monday to Friday, 9H00am to 6H00pm )
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  23 AAPPPPEENNDDIIXX  11  --  FFIINNGGEERRPPRRIINNTT  PPLLAACCEEMMEENNTT  RRUULLEESS  To ensure a good quality contact of your finger on the terminal you must leave your finger on the sensor until sensor light is turned off. Fingerprint Placement  Fingerprint Orientation Area containing most of the informationFingerprint Inclination  Fingerprint Rotation
 24 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  SK-0000034370-01 AAPPPPEENNDDIIXX  22  --  BBIIBBLLIIOOGGRRAAPPHHYY   Configration Guide : MA1xx Series This guide gives all informations about  terminal parameters.  MorphoAccess Host System Interface Specifications Describes MorphoAccessTM communication protocol (Serial and Ethernet).  MorphoAccess Remote Messages Specifications Complete specifications describing remote messages send during control (Wiegand, Dataclock, Ethernet and Serial).  Finger Positioning Highlight finger-positioning principles ( See Appendix 1 )  MA2G CFG Editor This tool allows parameters configuration. Use Ethernet link.  MA2G Downloader This software is designated to update MorphoAccessTM firmware.
 SK-0000034370-01  SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.  25 AAPPPPEENNDDIIXX  33  --  DDRRIILLLLIINNGG  TTEEMMPPLLAATTEE    Screw : 4 mm Screw : 3 mm
 SAGEM Défense Sécurité Siège social : Le Ponant de Paris 27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE Société anonyme à directoire et conseil de surveillance au capital de 36 405 229 € 562 082 909 RCS PARIS

Navigation menu