Sagem Wireless MA110 MA110 User Manual Installation Guide

Sagem Wireless MA110 Installation Guide

Contents

Installation Guide

Download: Sagem Wireless MA110 MA110 User Manual Installation Guide
Mirror Download [FCC.gov]Sagem Wireless MA110 MA110 User Manual Installation Guide
Document ID706282
Application IDYb2JN0qdv1fsRFO+jgjZ7Q==
Document DescriptionInstallation Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize114.42kB (1430254 bits)
Date Submitted2006-09-19 00:00:00
Date Available2006-09-19 00:00:00
Creation Date2005-12-21 21:49:24
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-12-21 21:49:24
Document TitleMicrosoft Word - Copie de Installation Guide MA2G SK 34370-01.doc
Document CreatorPScript5.dll Version 5.2
Document Author: g073240

MORPHOACCESS
TM
Installation Guide
MA1xx series
MorphoAccessTM 100/110/120
November 2005
SK 0000034370 - 01
2
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
CONTENTS
INTRODUCTION
SAFETY INSTRUCTIONS
GENERAL DESCRIPTION
INSTALLATION PROCEDURE
10
STAGE 1 : DRILLING THE CHASSIS MOUNTING HOLES
STAGE 2 : CABLE ENTRY HOLE LOCATION AND CHASSIS FIXATION
STAGE 3 : CONNECTING THE COVER ASSEMBLY TO THE CHASSIS
STAGE 4: CLOSING MORPHOACCESS™
10
11
12
13
ELECTRICAL INTERFACE
14
TERMINAL BLOCK BOARD WIRING
POWER SUPPLY CABLE
WIEGAND OUTPUT WIRING
DATA CLOCK OUTPUT WIRING
COM RS485 SERIAL PORT
ETHERNET WIRING
OUTPUT RELAY
TAMPER SWITCH
14
16
16
17
17
18
19
19
USER INTERFACE
20
RECOMMENDATIONS
21
APPENDIX 1 - FINGERPRINT PLACEMENT RULES
23
APPENDIX 2 - BIBLIOGRAPHY
24
APPENDIX 3 - DRILLING TEMPLATE
25
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
4
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
INTRODUCTION
Congratulations for choosing the SAGEM MorphoAccess™1 Automatic
Fingerprint Recognition Terminal. MorphoAccess™ provides an innovative
and effective solution for access control applications using Fingerprint
Verification or/ and Identification.
Among a range of alternative biometric techniques, the use of finger
imaging has significant advantages : each finger constitutes an unalterable
physical signature which develops before birth and is preserved until
death. Unlike DNA, a finger image is unique to each individual - even
identical twins.
The MorphoAccess™ terminal integrates SAGEM image processing
and feature matching algorithms (MorphoSoft™ and MorphoImaging™).
This technology is based on lessons learned during more than 20 years of
experience in the field of biometric identification and the creation of literally
millions of individual fingerprint identification records.
We believe you will find the SAGEM MorphoAccess™ fast, accurate, easy
to use and suitable for physical access control.
The SAGEM MorphoAccess™ offers the following advantages:
•
High quality optical sensor.
•
Supports multiple input/output interfaces used in the physical
access control industry.
•
Local area network interface for easy interaction with other host
systems.
•
Very compact size for easy installation and integration into your
available office space.
•
Open architecture, with dedicated applications implemented via
MA1xx Software Development Kit.
To ensure the most effective use of your SAGEM MorphoAccess™, we
recommend that you read this Installation Guide totally.
The SAGEM logo and trademark are the property of SAGEM Défense Sécurité.
All other trademarks or product names are trademarks or product names of the respective title
holders.
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SAFETY INSTRUCTIONS
The installation of this product should be made by a qualified service
Person and should conform to all local codes.
It is strongly recommended to use a class II power supply at 12 V ±5% and
0.5 A. min according with Safety Electrical Low Voltage (SELV). The 12 V
power supply cable length should not exceed 5 meters.
This product is intended to be installed with a power supply conformed to
EN60950, in accordance with the NEC Class 2 requirements ; or supplied
by a listed EN60950 external Power Unit marked Class 2 , Limited Power
source, or LPS and rated 12 V DC, 0.5 A minimum.
In case of building to building connection it is recommended to connect 0V
to ground. Ground cable must be connected with the terminal block 0V
GND.
Europe information’s : SAGEM hereby declares that the SAGEM
MorphoAccess™ has been tested and found compliant with the below
listed standards as required by the EMC Directive 89/336/EEC: EN55022
(1994) / EN55024 (1998) , EN300-330 (1999) and by the low voltage
Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000).
USA information’s : This equipment has been tested and found
compliant with Class B digital device requirements, pursuant to part 15 of
the FCC Rules. These requirements are designed to ensure reasonable
protection against harmful RF interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
interfere with radio communications. If this equipment interferes with radio
or television reception - which can be determined by disconnecting and reconnecting the unit – the user is encouraged to try to correct the
interference by one or more of the following measures :
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
GENERAL DESCRIPTION
Optical Sensor
Contactless Card reader
( depending of the versions)
Terminal Block
Tamper switch
Trap door
Power supply cable
Mounting keyholes
Cable entry
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
MorphoAccess™ supplies :
1 Cover assembly
1 Chassis
1 Trap door
2 screws for cover fixation
1 secured screwdriver Torx 20
1 secured screw for trap door fixation
Qty
Cover assembly
Chassis
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
1
Trap door
Screws for cover fixation
into the chassis.
Secured screw for trap
door fixation
Secured screwdriver
Torx 20
In order to proceed to MorphoAccess installation , you’ll need a standard 2,5mm
screwdriver.
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
INSTALLATION PROCEDURE
Stage 1 : Drilling the chassis mounting holes
(a) Screw : 4 mm
(b) Screw : 3 mm
I. For choice, drill the 4 corners holes (a) for the screws for the mounting
keyholes so that the cable entry is in a suitable position for your cabling,
using the dimensional drawing above.
II. In case of electric plug connections , MorphoAccess™ terminal may be
installed directly on US or European plugs , with some of the 5 holes (b).
So, drill the needed holes.
10
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
Stage 2 : Cable entry hole location and chassis fixation
Cable entry
Cable entry
I. Pass the all connecting cables through the 2 cable entry. Be sure during
manipulation that power supply from electric source is off.
II. Fit the screws chassis fixation.
The mounting screws must be 4 mm diameter maximum for corner place
(a) and 3 mm diameter maximum for other places (b).
Small head screws are required.
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
11
Stage 3 : Connecting the cover assembly to the chassis
( II )
Screw chassis fixation
Screw chassis fixation
I. Pass all connecting cable into cover entry holes.
II. Put the cover assembly into the chassis hanging
III. Fit the 2 screws chassis fixation , supplied with MorphoAccess™
IV. Connect cables to terminal blocks (see the detailed instructions in
the following sections)
12
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
Stage 4: Closing MorphoAccess™
(I)
( II )
I. Push up the trap door along the cover assembly
II. Fit the M4x20 assembly secured screw ( use screwdriver Torx 20S
supplied with MorphoAccess™ )
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
13
ELECTRICAL INTERFACE
Terminal block board wiring
Various interfaces
14
USB master connector
Power supply source
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
1
10
11
12
13
14
USB
15
Pin 1
TR- / D1
Out
Wiegand D1 or RS485 TX/RX- or CLK
Pin 2
TR+ / D0
Out
Wiegand D0 or RS485 TX/RX+ or Data
Pin 3
LED1
In
Wiegand LED1
Pin 4
LED2
In
Wiegand LED2
Pin 5
GND
Pin 6
Relay C0
Contact Relay 0
Pin 7
Relay C1
Contact Relay 1
Pin 8
TSW0
Tamper switch Contact 0
Pin 9
TSW1
Tamper switch Contact 1
Pin 10
GND
Ground for Ethernet Interface (LAN 10/100 Mbps)
Pin 11
RX-
Receive negative Ethernet
Pin 12
RX+
Receive positive Ethernet
Pin 13
TX-
Transmit negative Ethernet
Pin 14
TX+
Transmit positive Ethernet
Pin 15
+12V
Positive 12 Volts , power supply.
Pin 16
GND
Ground power supply.
SK-0000034370-01
16
Ground for Wiegand / RS485 / Dataclock
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
15
Power supply cable
10
11
12
13
14
Pin 15
+12V
Positive 12 Volts , power supply.
Pin 16
GND
Ground power supply.
15
16
Power supply :
Must be conformed to CEE/EEC EN60950 standard
12 Volts ± 5% (regulated) 0.5 Amp.
It could be coming from 12 Volts Wiegand power supply , conforms to the
Security Industry Association's Wiegand standard March 1995.
Wiegand output wiring
10
11
12
Pin 1
TR- / D1
Out
Wiegand D1
Pin 2
TR+ / D0
Out
Wiegand D0
Pin 3
LED1
In
Wiegand LED1 ( option )
Pin 4
LED2
In
Wiegand LED2 ( option )
Pin 5
GND
13
14
15
16
Ground for Wiegand / RS485 / Dataclock
Electrical interface conforms to the Security Industry Association's Wiegand standard
March 1995, and it is 5V TTL compatible.
16
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
Data Clock output wiring
Pin 1
TR- / D1
Out
Clock
Pin 2
TR+ / D0
Out
Data
Pin 5
GND
10
11
12
13
14
15
16
15
16
Ground for Wiegand / RS485 / Dataclock
The electrical interface is 5V TTL compatible.
COM RS485 serial port
10
Pin 1
TR- / D1
Out
RS485 TX/RX-
Pin 2
TR+ / D0
Out
RS485 TX/RX+
Pin 5
GND
11
12
13
14
Ground for Wiegand / RS485 / Dataclock
For a half-duplex RS485 connection, only Tx/Rx+ , Tx/Rx- and ground reference
signals are necessary.
Depending on RS485 network , an impedance adaptation may be required.
A 120 Ohms resistor termination may be added to the terminal , by strapping pin 1
and pin 2 of the auxiliary connector.
SK-0000034370-01
10
11
12
10
13
14
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
15
16
17
Ethernet wiring
10
11
12
13
14
15
Pin 10
GND
Ground for Ethernet Interface (LAN 10/100 Mbps)
Pin 11
RX-
Receive negative Ethernet
Pin 12
RX+
Receive positive Ethernet
Pin 13
TX-
Transmit negative Ethernet
Pin 14
TX+
Transmit positive Ethernet
16
RJ 45 cabling recommendation :
RJ45 plug pinout is compliant with 10 base T , IEEE802.3 Specification.
Pinout
Signals
EIA/TIA
T568B color
EIA/TIA
T568A color
Corel L120
color
TD(+) Transmit Data Plus
(Output)
White Orange
White Green
Grey
TD(-) Transmit Data Minus
(Output)
Orange
Green
White
RX(+) Receive Data Plus
(Input)
White Green
White Orange
Pink
No connection
Blue
Blue
Orange
No connection
White blue
White blue
Yellow
RX(-) Receive Data Minus
(Input)
Green
Orange
Blue
Ground protection ( option )
White Brown
White Brown
Purple
No connection
Brown
Brown
Brown
18
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
Output relay
10
11
Pin 6
Relay C0
Contact Relay 0
Pin 7
Relay C1
Contact Relay 1
12
13
14
15
16
Relay ratings
1 A at 30 VDC according to the safety extra low voltage requirements
(42.4 VAC max, 60 VDC max) independently of the power supply.
Tamper switch
10
11
12
Pin 8
TSW0
Tamper switch Contact 0
Pin 9
TSW1
Tamper switch Contact 1
13
14
15
16
Tamper-switch ratings
50 mA at 20 VDC max according to the safety extra low voltage.
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
19
USER INTERFACE
MorphoAccess™ terminal works upon three principles : Access control
with identification, access control with authentication, and proxy mode.
These three principles consist in five functional modes :
• Mode 0 : Local identification (fingerprint capture) with a local base,
MA100 default mode
• Mode 1 : Reserved
• Mode 2 : Proxy mode; Command sending to the MorphoAccess™
• Mode 3 : Authentication (contactless card reading minutiae) and
fingerprint capture
MA100 and MA120 default mode
• Mode 4 : Authentication (contactless card
fingerprint capture with a local base
reading
ID)
and
• Mode 5 : Modes 0 and 3, merged
• Mode 6:
Reserved
The MorphoAccess™ 1xx series manage one base of 500 persons with 2
fingers, locally or remotely.
20
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
Recommendations
Areas containing combustibles
It is strongly recommended that you do not install your SAGEM
MorphoAccess™ in the vicinity of gas stations, petroleum processing
facilities or any other facility containing flammable or combustible gasses
or materials.
General precautions
•
Do not attempt to repair your SAGEM MorphoAccess™
yourself. The manufacturer cannot be held responsible for any
damage/accident that may result from attempts to repair
components. Any work carried out by non-authorized personnel
will invalidate your warranty.
•
Do not use your SAGEM MorphoAccess™ in damp areas
(swimming pool...). Protect it from water and other liquids.
•
Do not expose your SAGEM
temperatures.
•
Use your SAGEM MorphoAccess™ with original accessories.
Attempts to integrate the MorphoAccess™ with unapproved
accessories will void your warranty.
•
Due to electrostatic discharge, and depending on the
environment, synthetic carpet should be avoided in areas where
the SAGEM MorphoAccess™ has been installed.
MorphoAccess™ to extreme
Ethernet connection
It is recommended to use a category 5 shielding cable (120 OHM). It is
also strongly recommended to insert a repeater unit every 90 m.
Extreme care must be taken while connecting Ethernet wire to the terminal
block board since low quality connection may strongly impact Ethernet
signal sensibility.
It is recommended to connect Rx+ and Rx- with the same twisted-pair wire
(and to do the same with Tx+/Tx- and the other twisted-pair wire).
Date / Time synchronisation
If you except to use the MorphoAccessTM for application requiring high
time precision we recommend to synchronize regularly your terminal time
with an external clock.
The terminal clock has a 40 10-6 ppm time deviation.
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
21
Cleaning precautions
A dry cloth should be used.
Warning
The manufacturer cannot be held responsible if the above
recommendations are not followed or if the SAGEM MorphoAccess™ is
incorrectly used.
Biometrics Terminals Hot-Line
To Access this service, please call us in order to get your login. Please send email
rather call the hot-line.
Email: hotline.biometrics@sagem.com
Tel : + 33 1 34 30 39 19 (Monday to Friday, 9H00am to 6H00pm )
22
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
APPENDIX 1 - FINGERPRINT PLACEMENT RULES
To ensure a good quality contact of your finger on the terminal you must
leave your finger on the sensor until sensor light is turned off.
Area containing most of the information
SK-0000034370-01
Fingerprint Placement
Fingerprint Orientation
Fingerprint Inclination
Fingerprint Rotation
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
23
APPENDIX 2 - BIBLIOGRAPHY
Configration Guide : MA1xx Series
This guide gives all informations about terminal parameters.
MorphoAccess Host System Interface Specifications
Describes MorphoAccessTM communication protocol (Serial and
Ethernet).
MorphoAccess Remote Messages Specifications
Complete specifications describing remote messages send during
control (Wiegand, Dataclock, Ethernet and Serial).
Finger Positioning
Highlight finger-positioning principles ( See Appendix 1 )
MA2G CFG Editor
This tool allows parameters configuration. Use Ethernet link.
MA2G Downloader
This software is designated to update MorphoAccessTM firmware.
24
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000034370-01
APPENDIX 3 - DRILLING TEMPLATE
Screw : 4 mm
Screw : 3 mm
SK-0000034370-01
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
25
SAGEM Défense Sécurité
Siège social : Le Ponant de Paris
27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE
Société anonyme à directoire et conseil de surveillance
au capital de 36 405 229 € 562 082 909 RCS PARIS

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2005:12:21 21:49:24+01:00
Modify Date                     : 2005:12:21 21:49:24+01:00
Page Count                      : 26
Creation Date                   : 2005:12:21 20:49:24Z
Mod Date                        : 2005:12:21 20:49:24Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : g073240
Metadata Date                   : 2005:12:21 20:49:24Z
Creator                         : g073240
Title                           : Microsoft Word - Copie de Installation Guide MA2G SK 34370-01.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M9H-MA110

Navigation menu