Sagem Wireless MA520 MA520, OMA520 User Manual DOC MA

Sagem Wireless MA520, OMA520 DOC MA

Contents

Installation Guide

  MorphoAccessTM  Installation Guide MA500 Series        Produced by Sagem Sécurité  Copyright ©2007 Sagem Sécurité www.sagem-securite.com MorphoAccessTM Installation guide OMA520/521 and MA500/520/521 July 2007SK 0000053018-03
 2 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
   CONTENTS  INTRODUCTION 5 SAFETY INSTRUCTIONS 6 EUROPE INFORMATION : 6 USA INFORMATION 7 CANADIAN INFORMATION 7 GENERAL DESCRIPTION 8 MA5XX VERSIONS INSTALLATION PROCEDURE 10 STAGE 1: DRILLING THE MOUNTING HOLES 10 STAGE 2: MOUNTING THE METAL CHASSIS ASSEMBLY 11 STAGE 3: CONNECTING THE CHASSIS ASSEMBLY TO THE COVER ASSEMBLY 12 STAGE 4: CLOSING MORPHOACCESS™ 13 OMA5XX VERSIONS INSTALLATION PROCEDURE 14 STAGE 1: DRILLING THE MOUNTING HOLES 14 STAGE 2 : OMA5XX FIXING 15 STAGE 3 : OMA5XX CABLING 15 STAGE 4 : CLOSING OMA5XX 15 ELECTRICAL INTERFACE 16 MA5XX TERMINAL BLOCK BOARD WIRING 16 OMA5XX REAR VIEW AND CABLES 17 POWER SUPPLY SOURCE 18 WIEGAND OUTPUT WIRING 19 DATA CLOCK OUTPUT WIRING 19 WIEGAND INPUT WIRING 20 DATA CLOCK INPUT WIRING 20 COM RS422 SERIAL PORT 21 COM RS485 SERIAL PORT 21 ETHERNET WIRING 22 OUTPUT RELAY AND SECURITY SWITCHES 23 USER INTERFACE 25 SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  3
 MORPHOACCESSTM MA5XX SERIES TECHNICAL CHARACTERISTICS 26 MAN MACHINE INTERFACE 26 BIOMETRY 26 PERIPHERALS INTERFACES 26 POWER SUPPLY 27 SIZE AND WEIGHT 27 ENVIRONNEMENTAL CONDITIONS 28 RECOMMENDATIONS 29 AREAS CONTAINING COMBUSTIBLES 29 GENERAL PRECAUTIONS 29 SPECIFIC PRECAUTIONS FOR RADIO TERMINALS 29 ETHERNET CONNECTION 30 DATE / TIME SYNCHRONIZATION 30 CLEANING PRECAUTIONS 30 WARNING 30 BIOMETRICS TERMINALS HOT LINE 30 APPENDIX 1 - FINGERPRINT PLACEMENT RULES 31 APPENDIX 2 – RELATED DOCUMENTS 32 APPENDIX 3 - DRILLING TEMPLATE 34 MA5XX VERSIONS 34 OMA5XX VERSIONS 35 SUPPORT 36 CUSTOMER SERVICE 36 HOTLINE 36 4 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 IINNTTRROODDUUCCTTIIOONN  Congratulations for choosing the SAGEM MorphoAccess™1 Automatic Fingerprint Recognition Terminal. MorphoAccess™ provides an innovative and effective solution for access control applications using Fingerprint Verification or/ and Identification. Among a range of alternative biometric techniques, the use of finger imaging has significant advantages: each finger constitutes an unalterable physical signature which develops before birth and is preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins. The MorphoAccess™ terminal integrates SAGEM image processing and feature matching algorithms (MorphoSoft™ and MorphoImaging™). This technology is based on lessons learned during more than 20 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records. We believe you will find the SAGEM MorphoAccess™ fast, accurate, easy to use and suitable for physical access control. The SAGEM MorphoAccess™ offers the following advantages: •  High quality optical sensor ( IQS certified ) •  Supports multiple input/output interfaces used in the physical access control industry. •  Local area network interface for easy interaction with other host systems. •  Compact size for easy installation and integration into your available office space. •  Intuitive man machine interface with keyboard and display, that is easy to use in both setup and operational modes. •  Open architecture, with dedicated applications implemented via MA5xx/1xx Software Development Kit.  To ensure the most effective use of your SAGEM MorphoAccess™, we recommend that you read this Installation Guide thoroughly.                                              1 The SAGEM logo and trademark are the property of SAGEM Sécurité. All other trademarks or product names are trademarks or product names of the respective title holders. SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  5
 SSAAFFEETTYY  IINNSSTTRRUUCCTTIIOONNSS  The installation of this product should be made by a qualified service technician and should conform to all local codes. It is strongly recommended that a class II power supply at 12 V ±5% and 0.75 A. min be used in accordance with Safety Electrical Low Voltage (SELV) parameters. The 12 V power supply cable length should not exceed 5 meters. This product may be installed with a power supply conforming to EN60950, in accordance with the NEC Class 2 requirements; or supplied by a listed EN60950 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12 V DC, 0.75 A minimum. In case of “Power Over Ethernet” use, the POE hub or switch features has to be conformed with IEEE 802.3-af standard. An insulation greater than 2000V is provided between MA5xx terminal and Ethernet network. In case of building to building connection it is recommended to connect 0V to ground. This ground (ground security reference) cable must be connected with the terminal block board fixation screw marked with the universal ground symbol ( see p16 ). EEuurrooppee  iinnffoorrmmaattiioonn  ::  SAGEM hereby declares that the SAGEM MorphoAccess™ has been tested and found compliant with the following listed standards as required by the EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998), EN300-330 (1999) and by the low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000). Caution:  The MA500 terminal is a Class A device. In a residential environment, this device may cause interference. In this case, the user is encouraged to try to correct the interference with appropriated measures such as :  •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help.  6 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 UUSSAA  iinnffoorrmmaattiioonn  Caution:  FCC part 15 certificates are pending. This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Responsible Party : Sagem Morpho Inc, 1145 Broadway Plaza, Suite 200, Tacoma, Washington (USA), 98402, (800) 346-2674. Note : This equipment has been tested and found to comply with the limits for a Class B (MA520, MA521, OMA520, OMA521)  or Class A (MA500) digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help. CCaannaaddiiaann  iinnffoorrmmaattiioonn  Caution:  Industrial Canadian certificates are pending. This Class B (MA520, MA521, OMA520, OMA521)  or Class A (MA500) digital apparatus complies with Canadian ICES-003. Ces appareils numériques de Classe B (MA520, MA521, OMA520, OMA521)  ou Classe A (MA500) sont conformes à la norme NMB-003 du Canada.  SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  7
 GGEENNEERRAALL  DDEESSCCRRIIPPTTIIOONN  MA5xx versions  Display  128 x 64 dots SensorFunction keys  Keyboard MIFARECard reader( MA520 / 521 only )   Mounting keyholes  Cable entry Metal chassisAnti-theftentry MorphoAccess™ supplies: 1 Cover assembly with Chassis and 2 Secured screws for fixation 1 Secured screwdriver Torx 20   1 Chassis fixation kit ( 4 fixations and screws , 1 anti theft block ) 8 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 OMA5xx versions     Display  128 x 64 dots Function keys  Keyboard MIFARECard reader( MA520 / 521 only )SensorProtective visor4 Mounting slots Outdoor MorphoAccess™ supplies: 1 Cover assembly with chassis and protective visor 1 Secured screwdriver Torx 10 1 Chassis fixation kit ( 4 fixations and screws ) SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  9
 MMAA55XXXX  VVEERRSSIIOONNSS  IINNSSTTAALLLLAATTIIOONN  PPRROOCCEEDDUURREE  SSttaaggee  11::  DDrriilllliinngg  tthhee  mmoouunnttiinngg  hhoolleess  Mounting and cable entry hole location (rear view) 10 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03    a) Using  the  dimensional drawing in Appendix 3, drill 2 holes for the mounting keyholes screws so that the cable entry is in a suitable position for cabling. b) Drill the hole for the third screw in the center of the slot so that it is possible to correct the position later, if necessary. c) The mounting screws must be 5 mm diameter maximum.
  SSttaaggee  22::  MMoouunnttiinngg  tthhee  mmeettaall  cchhaassssiiss  aasssseemmbbllyy    Anti theft switch Cable entryTerminal block board Chassis bold receivers  a)  Disconnect the ribbon cable between the motherboard and the terminal block board so that the assembly shown above can be detached from the rest of MorphoAccess™. b)  Pass the connecting cables through the cable entry. c)  Position the chassis assembly against the wall using the two screws in the mounting keyholes. d)  Hold the chassis in place with a screw through the mounting slot. e) Adjust the position, and fix in place by tightening all three screws. f)  Adjust the anti theft block into the hole designed for it, and fix in place the last and fourth screw. Check that nothing is interfering with the anti theft switch ( opto component ) and the anti theft block. g)  Connect cables to terminal blocks with adequate torque conformed to screw dimensions ( see the detailed instructions in the following sections )    Be sure during manipulation that the power supply from the electrical source is off.  SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  11
 SSttaaggee  33::  CCoonnnneeccttiinngg  tthhee  cchhaassssiiss  aasssseemmbbllyy  ttoo  tthhee  ccoovveerr  aasssseemmbbllyy  Ribbon cable connector location  Tamper switch     Cover assembly  Chassis assembly Motherboard/terminal block board ribbon cable connector  Position of the ribbon cable as the case is closed   Cover assemblyChassis assemblyThe ribbon cable must be folded asshown so that the case closeseasily without damaging the cable12 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 SSttaaggee  44::  CClloossiinngg  MMoorrpphhooAAcccceessss™™   SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  13  Catch for the cover assembly lip Lip When the ribbon cable has been connected between the two assemblies (see stage 3), the cover assembly is fitted to the chassis assembly. 1  The lip on the cover slides behind the chassis, to fit over the catch shown on the diagram above. 2  The cover is fitted onto the chassis by rotating it.    Fit the two M4x16 assembly screws. Use screwdriver TORX 20 Assembled MorphoAccessTM
 OOMMAA55XXXX  VVEERRSSIIOONNSS  IINNSSTTAALLLLAATTIIOONN  PPRROOCCEEDDUURREE  SSttaaggee  11::  DDrriilllliinngg  tthhee  mmoouunnttiinngg  hhoolleess  Mounting hole location (rear view)    a) Using the dimensional drawing for OMA5xx in Appendix 3, drill holes for the four mounting bolts, vertically centered within the four slots. b)  The mounting bolts must be 5 mm diameter maximum.  14 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 SSttaaggee  22  ::  OOMMAA55xxxx  ffiixxiinngg  a)  Remove protective visor ( 4 small caps at each corner ) before fixing OMA5xx assembly. Remove the 4 small caps at each corner of the protective visor , with a small screw driver  Remove the 4 screws , with T10 screw driver supplied. b)  Adjust the OMA5xx assembly in front of the 4 holes. c)  Fix the 4 mounting bolts ( 2 in upper zone , 2 in lower zone ) SSttaaggee  33  ::  OOMMAA55xxxx  ccaabblliinngg  a) Connect necessary OMA cables to user wires ( see the detailed instructions in the following sections ) SSttaaggee  44  ::  CClloossiinngg  OOMMAA55xxxx  a)  Mount protective visor with 4 screws and T10 screw driver. b)  Put the 4 small caps. SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  15
 EELLEECCTTRRIICCAALL  IINNTTEERRFFAACCEE  MMAA55xxxx  TTeerrmmiinnaall  bblloocckk  bbooaarrdd  wwiirriinngg   16 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03       Anti theft opto Wiegand IN Dataclock IN Relay Tamper switch Anti theft switch COM RS422 / RS485 Wiegand OUT Dataclock  OUT  Power supply source External +12V DC or Power Over Ethernet Ground security reference Ethernet Terminal blockor RJ45
 OOMMAA55xxxx  rreeaarr  vviieeww  aanndd  ccaabblleess     Power Supply source Tamper switch  RelayCOM RS422/ 485 Wiegand DataClockEthernet RJ45     Wiring ( cables colors and cables positions ) is not exactly the same as previous OMA2xx/3xx family.  In order to be complied with EMC directives ( See p 6 ), all cables coming from Access Control system must be shielded. Both shield wires ( OMA5xx cable , AC system cable ) must be tied together. Shield wire from OMA5xx cable is the wire without insulation.   SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  17
 PPoowweerr  SSuuppppllyy  ssoouurrccee           MA5xx  OMA5xx            Power cable 1    Block 1  +12V  In  Positive 12 Volts, power supply.  Red 2   Block 2 GND/ALIM  In  Ground power supply.  Black      Ground  In  Ground security reference  yellow/green Power supply: Must conform to CEE/EEC EN60950 standard 9V to 16 Volts ± 5% (regulated)    1,5 Amp max ( peak ) Power may come from a 12 Volts Wiegand power supply, conforming to the Security Industry Association's Wiegand standard March 1995 , able to deliver 9 Watts. In standard operating activity, typical power consumption is 4,5 Watts. In extreme temperature conditions, with all options ( USB key , 12V output for Wiegand in ), maximum power consumption is up to 9 Watts.  MA5xx terminal make use of POE functionality ; If Ethernet network is POE compatible, power supply may  come from Ethernet wiring.   For systems placed in other building than supervisor one's, the electrical security is guaranteed with a "ground connection" to the terminal. For a higher susceptibility level, we recommend to the installer to connect a "ground connection" to the terminal.  MA5xx : A cable terminal connected to "ground security reference" must be tied to the fixation designed for ( see p 16 ).  OMA5xx : the yellow/green wire in power supply cable must be connected to "ground security reference".  18 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 WWiieeggaanndd  oouuttppuutt  wwiirriinngg           MA5xx  OMA5xx            Wiegand Dataclock cable 1    Block 1  D0  Out  Wiegand D0  Green 2    Block 2  D1  Out  Wiegand D1  White 3    Block 3  LED1  In  Wiegand LED IN 1 (option)  Brown 4    Block 4  LED2  In  Wiegand LED IN 2 (option)  Grey 5    Block 5  GND    Ground for Wiegand  Black  Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible.  DDaattaa  CClloocckk  oouuttppuutt  wwiirriinngg           MA5xx  OMA5xx            Wiegand Dataclock cable 1    Block 1  D0  Out  Data  ( 5V TTL )  Green 2    Block 2  D1  Out  Clock ( 5V TTL )  White 3   Block 3  LED1    NC  NC 4   Block 4  LED2    NC  NC 5    Block 5  GND    Ground for Dataclock  Black SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  19
 WWiieeggaanndd  iinnppuutt  wwiirriinngg           MA5xx  OMA5xx            Wiegand Dataclock cable 1    Block 1  D0  In  Wiegand D0  Blue 2    Block 2  D1  In  Wiegand D1  Yellow 3    Block 3  LED  Out  Wiegand LED OUT 1 (option)  Orange 4    Block 4  +12V  Out  12 Volts Power output  (150 mA max)  Red 5    Block 5  GND    Ground for Wiegand  Black  Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible. DDaattaa  CClloocckk  iinnppuutt  wwiirriinngg           MA5xx  OMA5xx            Wiegand Dataclock cable 1    Block 1  D0  In  Data  ( 5V TTL )  Blue 2    Block 2  D1  In  Clock ( 5V TTL )  Yellow 3   Block 3  LED    NC  NC 4    Block 4  +12V  Out  12 Volts Power output  (150 mA max)  Red 5    Block 5  GND    Ground for Dataclock  Black 20 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 CCOOMM  RRSS442222  sseerriiaall  ppoorrtt           MA5xx  OMA5xx            COM RS422/RS485 cable 1    Block 1  GND    Ground for RS422  Grey or White 2    Block 2  Tx-  Out  RS422 Negative Transmit  Orange 3    Block 3  Tx+  Out  RS422 Positive Transmit  Orange/White 4    Block 4  Rx-  In  RS422 Negative Receive  Green 5    Block 5  Rx+  In  RS422 Positive Receive  Green/White  RS422 interface is a full duplex communication.  CCOOMM  RRSS448855  sseerriiaall  ppoorrtt           MA5xx  OMA5xx            COM RS422/RS485 cable 1    Block 1  GND    Ground for RS485  Grey or White 2    Block 2  Tx-  Out  RS485 Negative Transmit  Orange 3    Block 3  Tx+  Out  RS485 Positive Transmit  Orange/White 4   Block 4         5   Block 5          RS485 implementation is limited to half-duplex communication. So only Tx+ and Tx- and ground reference signals are necessary.  Depending on the RS485 network, an impedance adaptation may be required. For farthest terminal, a 120 Ohms resistor termination may be added to the terminal, by strapping block 2 and block 3. SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  21
 EEtthheerrnneett  wwiirriinngg  2 ways  for Ethernet wiring : - Terminal block connection ( MA5xx only )          MA5xx OMA5xx            Ethernet cable 1   Block 1  RX-  In  Receive negative Ethernet  RJ45 Pin 62    Block 2  RX+  In  Receive positive Ethernet  RJ45 Pin 33    Block 3  TX-  Out  Transmit negative Ethernet  RJ45 Pin 2 4    Block 4  TX+  Out  Transmit positive Ethernet  RJ45 Pin 1 5    Block 5  GND    Ground for shield Ethernet  RJ45 Pin 7  - RJ 45 cabling connection    RJ45 Pinout  Signals  EIA/TIA T568B color EIA/TIA T568A color Corel L120 color 1  TX(+) Transmit Data Plus  White Orange White Green  Grey 2  TX(-) Transmit Data Minus  Orange  Green White 3  RX(+) Receive Data Plus  White Green  White Orange  Pink 4 No connection  Blue  Blue  Orange 5  No connection  White blue  White blue  Yellow 6  RX(-) Receive Data Minus  Green  Orange Blue 7  Ground protection (option)  White Brown  White Brown  Purple 8 No connection  Brown  Brown  Brown  RJ45 plug pinout is compliant with 10/100 base T, IEEE802.3 Specification. RJ45 plug and Ethernet terminal block connections are compliant with Power Over Ethernet ( POE ) IEEE802.3 af  Specification. See details page 27. 22 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03Default IP address from factory setting is : 134.1.32.214
 OOuuttppuutt  rreellaayy  aanndd  sseeccuurriittyy  sswwiittcchheess          MA5xx OMA5xx           Switch/relay cable1    Block 1  CRO    Contact relay normally open  Red 2    Block 2  CRC    Contact relay normally closed  Orange 3    Block 3  CR    Contact relay common  Yellow 4    Block 6  TSW2_1    Tamper switch Contact 1  White 5    Block 7  TSW2-0    Tamper switch Contact 0  Green 6    Block 4  ATSW1_1    Anti theft switch Contact 1  Not available 7    Block 5  ATSW1_0    Anti theft switch Contact 0  Not available      Ground   Not connected  Black (*)   (*) : For this interface connection , it is not recommend to connect black wire to Ground. Various ground reference are not recommended.    This terminal is part of security system. In order to prevent unauthorized access into this terminal it is the customer’s responsibility to connect the tamper switch and the anti theft switch ( MA5xx only )  to the physical access controller (connected mode).  Anti-theft and tamper switchs ratings 2 A at 30 VDC according to the safety extra low voltage requirements (62.5 VAC max, 220 VDC max and 125 VAC max) independently of the power supply. The tamper function is activated with the proper screw positioning, between cover and chassis. Terminal closed :  Tamper switch ON Terminal open :  Tamper switch OFF  The anti theft function is activated by the anti theft block positioning in front of the opto component  ( not available with OMA5xx ) Terminal on wall :  Anti theft switch ON Terminal out wall :  Anti theft switch OFF SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  23
  “Security Loop” connection example : TSW1_0 TSW1_1 ATSW1_0 ATSW1_1"Security Loop"Physical Access Controler   Relay  ratings 2 A at 30 VDC according to the safety extra low voltage requirements (62.5 VAC max, 220 VDC max and 125 VAC max) independently of the power supply.  Inductive charge management require a parallel diode for a better contact lifetime.  Connection example about electrical door lock focus : MorphoAccessMA5xxCROPin 1CRPin 3+VCC( < 30 V )Electrical DoorLockOverswingDiodeBackside doorbutton 24 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 UUSSEERR  IINNTTEERRFFAACCEE  The MorphoAccess™ terminal functions in three operational modes: access control with identification, access control with authentication or verification, and proxy mode. These various modes are detailed in the MA500 Series User Guide. Terminal configuration may be done locally ( keyboard , USB key ) or remotely (using the configuration Tool or MEMS software) , by modifying key parameter. For MA5xx terminal management , MEMS software release must be at least v6.2.  MEMS™ : MorphoAccess Enrolment and Management System   SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  25
 MMOORRPPHHOOAACCCCEESSSSTTMM  MMAA55XXXX  SSEERRIIEESS  TTEECCHHNNIICCAALL  CCHHAARRAACCTTEERRIISSTTIICCSS  MMaann  MMaacchhiinnee  IInntteerrffaaccee  LCD display 128 x 64 pixels Alphanumeric and function keyboard ( 12 + 4 keypad ) Color LED for information Multi tone Buzzer Clock : +/- 4sec / day ( typical conditions ) , minimum 24 hours backup BBiioommeettrryy  Based on SAGEM MSO Biometric Module, FIPS IQS certified: 500dpi optical sensor Template Data base: 3000 persons with 2 fingers 5 x 10000 pers with 2 fingers and MA-X license option Identification: < 1,5s  ( 1000 persons in database ) Authentication / verification:  < 1s PPeerriipphheerraallss  iinntteerrffaacceess  Ethernet 10/100 Base T for remote control mode (terminal management) RS422 for remote control mode (terminal management)  Wiegand (output) or Dataclock ISO2 (output) or COM (RS485 2 wires) for output information. Wiegand Input Or Dataclock Input  to  interface an external reader  USB host for additional configuration Relay : 1 contact (open and closed) Tamper switch : Internal use (alarm message) and external contact. Anti theft : External contact (indoor MA5xx only) 26 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 PPoowweerr  ssuuppppllyy  9 to 16 Volts ± 5% and 1,5A peak power supply   Cable cross section depends on the length 0. 75mm2 recommended. Consumption :  750mA maximum rms @12V  ( < 1,5 A peak )   350mA typical rms @12V Power Over Ethernet compatibility ( IEEE802.3 af ) : Class 0 or Class 3 hub/switch equipment mandatory ( 15,4W )  MA5xx configurations   POE Alternative A compliant with RJ45 and terminal blocks POE Alternative B compliant with RJ45 only  OMA5xx configuration   POE Alternative A compliant only  “POE Alternative A” means power on data lines : Only 2 pairs are needed. “POE Alternative B” means power on 2 extra pairs lines : 4 pairs are required.  SSiizzee  aanndd  wweeiigghhtt  MA5xx version    160 x 145 x 75 mm 0,800 Kg  OMA5xx version  289 x 218 x 99 mm 2 Kg SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  27
 EEnnvviirroonnnneemmeennttaall  ccoonnddiittiioonnss  Operating temperature  -10 °C to + 50 °C. Operating humidity  10 % < RH < 80 %. Storage temperature  -20 °C to + 70 °C. Storage humidity  RH < 95 %. Hardness  MA5xx : IP30 ( indoor use only ) OMA5xx : IP65 (protection against rain and dust ) Light  We recommend MorphoAccess™ installation within controlled lighting conditions. Avoid direct exposure of sensor to sunlight. Avoid intensive UV lights.    28 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 RReeccoommmmeennddaattiioonnss  AArreeaass  ccoonnttaaiinniinngg  ccoommbbuussttiibblleess  It is strongly recommended that you do not install your SAGEM MorphoAccess™ in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials. GGeenneerraall  pprreeccaauuttiioonnss  •  Do not attempt to repair your SAGEM MorphoAccess™ yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty. •  Use your SAGEM MorphoAccess™ with original accessories. Attempts to integrate the MorphoAccess™ with unapproved accessories will void your warranty. •  Do not use your MA5xx SAGEM MorphoAccess™ in damp areas (swimming pool...). Protect your MA5xx from water and other liquids. •  Do not expose your SAGEM MorphoAccess™ to extreme temperatures. •  Do not expose MorphoAccess™ sensor to direct sunlight. OMA visor is able to mask sunlight. With MA terminals, a complementary visor may be added. •  Due to electrostatic discharge, and depending on the environment, synthetic carpet should be avoided in areas where the SAGEM MorphoAccess™ has been installed. SSppeecciiffiicc  pprreeccaauuttiioonnss  ffoorr  rraaddiioo  tteerrmmiinnaallss  It is recommended to install radio terminals ( MA520, MA521 , OMA520 and OMA521 ) at 30cm or more away from metallic elements, such as iron fixation or lift gate. Performances, in term of Contactless badges reading distance will decrease when metallic elements are in close proximity to the terminal. We advise persons with pacemaker or other electronic disposals against using this MA5x1 and OMA5x1 versions of MorphoAccess™ terminal. SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  29
 EEtthheerrnneett  ccoonnnneeccttiioonn  It is recommended to use a category 5 shielded cable (120 OHM). It is also strongly recommended to insert a repeater unit every 90 m. Extreme care must be taken while connecting Ethernet wire to the terminal block board since a low quality connection may strongly impact the Ethernet signal sensitivity. It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with the Tx+/Tx- using different twisted-pair wire). DDaattee  //  TTiimmee  ssyynncchhrroonniizzaattiioonn  If you expect to use the MorphoAccessTM for application requiring time precision we recommend that you synchronize your terminal time with an external clock at regular intervals. The terminal clock has a +/- 40 10-6 ( ppm ) typical time deviation at +25°C. Roughly , +/- 4 sec per day. At +50°C, the time deviation may be up to –8 sec per day CClleeaanniinngg  pprreeccaauuttiioonnss  A dry cloth should be used, specially for fingerprint sensor. Acid liquids, alcohol or abrasive materials are forbidden. WWaarrnniinngg  The manufacturer cannot be held responsible if the above recommendations are not followed or if the SAGEM MorphoAccess™ is incorrectly used.  BBiioommeettrriiccss  TTeerrmmiinnaallss  HHoott  Liinnee  To Access this service, please contact us in order to get your login. Please send an email rather than call the hot line.  Email: mailto:hotline.biometrics@sagem.comPhone : + 33 1 58 11 39 19 ( 9H00am to 5H00pm French Time , Monday to Friday )  30 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 AAPPPPEENNDDIIXX  11  --  FFIINNGGEERRPPRRIINNTT  PPLLAACCEEMMEENNTT  RRUULLEESS  To ensure a good quality contact of your finger on the terminal you must leave your finger on the sensor until the sensor light is turned off. Fingerprint Placement  Fingerprint Orientation Area containing most of the informationFingerprint Inclination  Fingerprint Rotation  SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  31
 AAPPPPEENNDDIIXX  22  ––  RREELLAATTEEDD  DDOOCCUUMMEENNTTSS  Administrator Information MA500 Series User Guide This document describes operating mode and terminal settings MA500 Series Configuration Application User Guide This document describes the configuration application processing MA500 Series Parameters Guide The complete description of terminal configuration files and registry keys This document gives also parameters default values. MA500 Series Enrolment application User Guide This document describes the local enrolment process and features MA500 Series Log viewer User Guide This document describes the log viewer process and features Developer Information MorphoAccess™ Host Interface Specification A complete description of remote management commands MorphoAccess™ Remote Messages Specification Details how the MorphoAccessTM sends the access control result to a Central Security Controller MorphoAccess™ Contactless Card Specification This document describes the MorphoAccessTM contactless card feature Support Tools Configuration Tool User Guide Configuration Tool user guide, via Ethernet USB Tool User Guide Configuration Tool user guide, via USB key 32 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
 MA500 Series Upgrade Tools User Guide Upgrade Tool user guide about firmware upgrading procedures Terminal Licence Management Download a licence in MorphoAccessTM  using “Terminal Licence Manager.exe” PC application. SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  33
 AAPPPPEENNDDIIXX  33  --  DDRRIILLLLIINNGG  TTEEMMPPLLAATTEE  34 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03MMAA55xxxx  vveerrssiioonnss    Anti theft block position     Scale :  1  ( Real dimensions )
 OOMMAA55xxxx  vveerrssiioonnss   70 135256  Attention : the above image dimensions do not match reality.  SK-53018-03  SAGEM Sécurité document. Reproduction and disclosure forbidden.  35
 SSUUPPPPOORRTT  CCuussttoommeerr  sseerrvviiccee  SAGEM Sécurité SAV Terminaux Biométriques Boulevard Lénine - BP428  76805 Saint Etienne du Rouvray  FRANCE  Tel: +33 2 35 64 55 05 HHoottlliinnee  SAGEM Sécurité  Support Terminaux Biométriques  24, Av du gros chêne  95610 Eragny – FRANCE  hotline.biometrics@sagem.com Tel: + 33 1 58 11 39 19  https://www.sagem-ds.com/biometrics-customersupport/Copyright ©2007 SAGEM Sécurité http://www.sagem-securite.com/36 SAGEM Sécurité document. Reproduction and disclosure forbidden.  SK-53018-03
   Siège social: Le Ponant de Paris 27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE

Navigation menu