Sagem Wireless MOV001 Handheld Top Up Terminal User Manual Movilway UG EN ES draft8

Sagem Wireless Handheld Top Up Terminal Movilway UG EN ES draft8

MOV001_UG_EN_ES_FCC_r2

Download: Sagem Wireless MOV001 Handheld Top Up Terminal User Manual Movilway UG EN ES draft8
Mirror Download [FCC.gov]Sagem Wireless MOV001 Handheld Top Up Terminal User Manual Movilway UG EN ES draft8
Document ID1329265
Application IDuXZxPqMePLph1pz62g2qDg==
Document DescriptionMOV001_UG_EN_ES_FCC_r2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize349.04kB (4363022 bits)
Date Submitted2010-08-19 00:00:00
Date Available2010-08-19 00:00:00
Creation Date2010-08-19 15:10:58
Producing SoftwareAdobe PDF library 7.77
Document Lastmod2010-08-19 15:10:59
Document TitleMovilway UG_EN_ES_draft8
Document CreatorAdobe Illustrator CS2

Introduction
USER GUIDE
MOV001
Description
Battery & SIM card
Congratulations, you have just purchased new terninal
MOV001.
It is recommended that you read this handbook carefully in order
to use your terninal efficiently and in the best conditions.
Paper compartment
Pull both sides of it to
open, then put into the
paper.
WARNING
Depending on the model, network configuration and associated
subscription cards, certain functions may not be available.
Java™ and all Java™ based trademarks and logos are
trademarks or registered trademarks of Sun Microsystems, Inc.
in the U.S. and other countries.
Large graphic display
Technical features
- Terminal
Weight: 300 g (with pager and battery)
Size: 190.7 X 81 X 54.5 mm
Original battery: Li-ion 900 mAh Battery life (*)
Standby time: up to 280 h
Connector for charger,
handset or USB cable.
Keyboards
- Power Supply Unit
Class equipment: Class II equipment
Electrical mains network: 100-240VCA/47-63 Hz
Power supply unit:
Exterbal detachable power supply unit 200 mA
Max consumption: 650 mA RMS
- For device using condition: Indoor device
Operating temperature: +5°C to +45°C
Operating humidity: 10 to 80 %RH (34°C {93°F} at 80 %,
non-condensing)
Storage temperature: -10°C to +55°C
- For paper roll:
Thermal Paper Specification:
-- Paper type: Single-ply thermal paper roll (Heat-sensitive
surface must be wrapped facing the outer side.)
-- Specified paper: Original Paper
No. TF50KS-E2C NIPPON PAPER INDUSTRIES CO., LTD.
TF50KS-E2D NIPPON PAPER INDUSTRIES CO., LTD.
KF50 KANZAN
P350 KSP
PD150R OJI PAPER CO., LTD.
PD160R OJI PAPER CO., LTD.
-- Size: 57.5 ± 0.5 (width) mm {2.26" ± 0.02"} × 80 mm {3.15"}
or less (outside diameter)
NOTES: Use the specified paper. Otherwise, the proper print
quality cannot be obtained, print head reliability may
decrease, or there may be damage to the print head.
Charge connection
Battery cover
Push and then pull
the battery cover
Battery & SIM card insertion
Switch off and disconnect the charger.
1. Push and then pull the battery cover, Take out battery if
already installed.
2. Slide the SIM card, with cut corner as shown on the terminal,
into the card holder with gold side down.
3. Place the battery by first inserting the upper section into the
opening.
4. Replace the back cover.
Battery charging procedure
1. The terminal is powered by a
rechargeable battery. It can be
recharge by plugging the charger as
shown on the picture.
2. A new battery must be charged for at
least 4 hours before being used for the
first time. It reaches its optimum capacity after a few cycles of use.
When the battery has been
discharged, the terminal displays the
state (empty battery icon flashes).
It is possible that the battery may heat
up slightly during charging, this
phenomenon is normal.
When you charge the battery, the
socket on which the charger is plugged
must be easily accessible.
Each terminal has a specific charger
with the appropriate connectors with
which it is sold. Using any other
charger, or using the charger with any
device other than the terminal will lead
to an exclusion of warranty.
WARNING
There is danger of explosion if the battery is placed in an
incorrect way or if it is exposed to fire.
Do not short circuit it.
The battery does not have any part that you can change. Do not
try to open the battery casing.
Use only the appropriate chargers and batteries as shown in
the phone manufacturer's catalogue.
The use of other types of chargers or batteries may be dangerous and invalidate the warranty.
Used batteries must be disposed of in the appropriate places.
We advise you to take the battery out if you plan not to use the
phone for extended periods.
You are strongly advised not to connect your terminal to the
charger if it doesn’t contain a battery.
The charger is a safety step-down transformer, it is forbidden to
modify, alter or replace it by another component (power supply
plug, etc).
If the battery has been entirely discharged the phone cannot
start. You must plug the charger to the mobile for a while, up to
30 minutes. Once the screen lights up, you can turn on your
terminal by press the START or a long press on the Red key.
Using the terminal
Switching ON
Long press the Red
key to switch ON. A short display
appears.
If access to the SIM card is protected, the terminal prompts you
to enter the PIN number: between 4 and 8 digits given to you
when the SIM card was issued. These digits do not appear on the
screen for security reasons.
WARNING
When a wrong PIN number is entered three times consecutively, your SIM card will be blocked. To unblock it:
- Enter the PUK (Personal Unblocking Key) code provided by
your operator, and validate.
- Enter a new PIN number and validate.
- Enter your new PIN number again and validate.
After 5 or 10 failed attempts (depending on the type of SIM
card), the SIM card is definitely locked. You must then contact
your operator or your SMC to obtain a new card.
Switching OFF
When the terminal is ON, short press the Red
Key to come
back to the idle screen. When at the idle screen, long press the
Red
Key to switch OFF.
Settings
- Phone
Profile: to select the profile as Normal or Silent mode. Silent
mode can also be accessed via the idle screen by holding down
the
key, and it does not remain after switching off your
terminal.
Sounds: to select Keypad beeps as Beep, Tones, Inactive or
Fun. To activate a beep for the Battery Beep.
Display: Select Wallpager to set a background picture from
different options.
Battery status: to display the status of the battery.
Date / Time: to set the date and time, select to set the Display
type, Time zone, Time format etc., select the Automatic update
to set as Automatic, On demand or Manual.
Languages: to select the display language. If select Automatic,
the language used will be the one relative to your SIM card.
- Connectivity
Network: Select Selection to activate Automatic or Manual of
the networks accessible. Select Prelerred to view all the preregistered networks. Select Network type to set the network as
GSM-DCS, PCS or Automatic. Select GPRS to set the way to
be connected on the GPRS network: always or only when
needed.
Java: to set various parameters to download Java applications.
Browser: Select Profiles to set or modify your provider’s
configuration settings or to configure others provider’s settings.
Select Connection time-out to choose the time after which the
call is automatically disconnected if you have forgotten to log off
from a service.
- Security
PIN number: to activate and modify the PIN number. Only after
activated the PIN number, it can be modified.
PIN2 number: you have a second PIN number to allow you to
access certain functions. These functions may or may not be
available depending on you SIM card.
Browsing
The browser navigator is under licence:
The browser navigator and the softwares included are the
exclusive property of Openwave. For this reason, it is forbidden
to modify, translate, disassemble or even decompile all or part of
these softwares.
- Bookmarks
To storebookmarks (addresses of Internet sites). A book mark
stored in the list can be modified, sent or deleted.
- History
Backward and forward navigation of the pages displayed are
kept in memory.
- Browser Reset
Select to clear the memory of Bookmarks, Cache, Cookies as
well as History.
My Files
This menu contains the directories of all the download objects.
This is where new version of the Movilway services will be
recorded after download.
Installing paper roll
- Open the paper compartment by lifting the catch loacted at the
rear of the MOV001 and pull the cover to the rear of the
terminal.
- Insert the paper roll in the compartment
- Pull the pager up to the top of the terminal
- Maintain the paper and close the lid
- Press simultaneously on both ends of the top of the paper flap,
until it clips into position.
Movilway
System Login
This login form will look as:
When the user has selected to load the
application, the login form will appear
on the screen. This is the first form and
can take some time to show to the user
because previously, the application
must check if there is a newer version
in the Movilway Repository. If so, the
application will perform the auto
update.
if the user press “Ok”, the application will try to log the user with
the system. If for some reason appear a problem with the login
process, the application will show an alert describing the problem
as showed next:
In this case “Login Incorrecto” means the system does not
recognize User/Password pair and reject the user. In this case,
the user must accept the notification pressing “Done”, the system
will go to the login screen again.
If the user can be logged without problems, the application will
show the Main Menu Form Discussed in next section.
Main Menu
The main menu form shows what
options are available to the user. The
form is showing next:
Each options means:
- New Sale
- Available Sale Capacity
- Sale Status
- Additional Sale Capacity Request
In order to do any task, the user must
move to the desired option, select it
and press “Ok” soft button. If the user
press “Exit” soft button, the application
leave this screen and go to the login
form previously described.
New Sale
As its name means, this option allow to
the user to do a new sale operation.
Only one product can be sold on each
sell process. The screen is showed
next:
This form has the necessary fields to
do a sale. There are three fields
described as:
- Producto: Is the product/services list
available to be sold, represented by
a Combo Box. When user select it,
the application allow to traverse the list in order to select what
product/service will be sold.
- Numero: Is the number used by recognize the client. If as
example, the client is trying to pay its phone account, this field
will contain the phone number. If the client is trying to pay its
electricity bill, the number will be the subscriber number and so
on.
- Monto: Is the amount in local money the client is paying.
When the user has filled all fields, in order to continue the sale
process, the key “Ok” must be pressed. If the user wants to
cancel operation he/she can press “Exit” button.
When the user choose to continue the sell process (pressing
Ok), the system will submit the sell request to the system, and in
some cases, the response will take some time to appear. The sell
transaction can be successful or not. If there is a problem with
the transaction in progress, the application will show an Alert as
show next (1):
In the above example, the application inform user about a
communication problem with the product provider. See the
number code “69” in the example. It is the response error code.
When transaction is approved, the screen showed to the user is
something like (2):
Safety
Declaration of conformity
Powering down the MOV001
Disconnect the MOV001 power supply unit from the electrical
mains network.
Lithium battery
The MOV001 is fitted with a lithium battery, which can only be
accessed and serviced by a qualified technician.
Electrical power outlet
The electrical outlet must meet the following criteria:
- Must be installed near the equipment and easily accessible;
- Must meet standards and regulations in the country where
used;
- EFT Smart can be connected to a power distribution system of
the IT type (tested for Norway only)
SAR (RF Exposure Information)
Terminal network
The terminal jack must comply with standards and regulations in
the country where used.
Opening up the terminal
The MOV001 must not be opened by the user.
The joins are sealed by labels. These must not be torn. They
provide proof that the terminal has not been opened.
Only the paper flap, battery cover can be opened and closed by
the user for routine servicing described in this guide.
(1)
(2)
Showing the incoming successfully transaction data
(unformatted until now).
If for any reason there is not clear if the transaction has been
successful or not, the user can use the option “Estado de Venta”
(Sale Status) located in the main menu. We will explain later how
to use that option.
Session Expiration Time
By default, the application has a session time limit where the user
can communicate to the system. This time begin to count when
the user log in in the system, and after the time expires, when the
user tries to do a new sale, the application redirect him/her to the
login screen.
Cleaning the terminal
Remove all cords from the terminal.
Use a soft cloth that is very slightly soaked with soapy water to
clean the outside of the terminal.
Do not clean the electrical connections.
Shipping and storage
Use the original packaging whenever shipping or storing the
terminal.
It is advisable to disconnect the cables from the terminal during
shipping.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
The antenna(s) used for this transmitter must not be co-located
or operating in conjunction with any other antenna or transmitter.
FCC Compliance
This mobile device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
This mobile device has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiated radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation If this equipment does cause
harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
This device meets the government’s requirements for exposure
to radio waves.
This device is designed and manufactured not to exceed the
emission limits for exposure to radio frequency (RF) energy set
by the Federal Communications Commission of the U.S. Government.
The exposure standard for wireless mobile devices employs a
unit of measurement known as the Specific Absorption Rate, or
SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR
are conducted using standard operating positions accepted by
the FCC with the device transmitting at its highest certified power
level in all tested frequency bands.
Although the SAR is determined at the highest certified power
level, the actual SAR level of the device while operating can be
well below the maximum value. This is because the device is
designed to operate at multiple power levels so as to use only the
poser required to reach the network. In general, the closer you are
to a wireless base station antenna, the lower the power output.
The highest SAR value for these device as reported to the FCC
when tested Body SAR at GPRS mode for all bands by separating 0cm from the device (both front and rear) to flat phantom. As
described in this user guide, the value is 1.170W/kg.
While there may be differences between the SAR levels of
various devices and at various positions, they all meet the
government requirement.
For body worn operation, to maintain compliance with FCC RF
exposure guidelines, use only accessories that contain no
metallic components and provide a separation distance of 15mm
(0.6 inches) to the body. Use of other accessories may violate
FCC RF exposure guidelines and should be avoided.
The FCC has granted an Equipment Authorization for this device
with all reported SAR levels evaluated as in compliance with the
FCC RF exposure guidelines. SAR information on this device is
on file with the FCC and can be found under the Display Grant
section of www.fcc.gov/oet/ea/fccid/ after searching on FCC ID:
M9HMOV001.
This device is compliance with SAR for general population
/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had
been tested in accordance with the measurement methods and
procedures specified in OET Bulletin 65 Supplement C.
End of life
The product belongs to the family of electrical and electronic
equipment. Therefore, it is subjected to the WEEE directive,
which requires the collection and the recycling at the end of life
product.
The movilway products present the symbol for the marking of
electrical and electronic equipment as required by the WEEE
Directive.
The crossed-out wheeled bin printed on the product gives
the information about the requirement not to dispose of
WEEE as unsorted municipal waste and to collect such
WEEE separately.
To assure that the product is collected and recycled with respect
to the environment, you must contact your supplier (in defect,
contact the movilway local office or the commercial head office in
charge of your country on www.movilway.com).
The abandonment or uncontrolled disposal of waste can cause
harm to environment and to human health. So, by recycling your
product in a responsible manner, you contribute to the preservation of natural resources and to the protection of human health.
Troubleshooting
The terminal does not turn on or does not connect to the
telephone line
- Check the power supply and telephone line cables
- Check for electrical power network
The terminal fails to establish a telephone connection
- Check that the tone of the phone line is free
- Check the configuration of the phone line and number to call
- Get technical support
The ticket is not printed
- Check the presence and proper positioning of the paper roll.
- Check the type of paper used (thermal paper must be used)
www.sagemwireless.com
Sagem Wireless
38 Rue de Berri, 75008 Paris
Capital 1 590 652, 10 € - 508 671 401 R.C.S Paris


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1.1-111
Format                          : application/pdf
Title                           : Movilway UG_EN_ES_draft8
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2010:08:19 15:10:58+08:00
Modify Date                     : 2010:08:19 15:10:59+08:00
Metadata Date                   : 2010:08:19 15:10:59+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 40
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 6151 bytes, use -b option to extract)
Document ID                     : uuid:A38420DA60ABDF1193ED82005324A60D
Instance ID                     : uuid:35c361ed-6e49-4d87-a1bc-14e0891b7990
Derived From Instance ID        : uuid:A28420DA60ABDF1193ED82005324A60D
Derived From Document ID        : uuid:D8B7DC523B69DF11885097AC3BE82A06
Producer                        : Adobe PDF library 7.77
Page Count                      : 1
Creator Version                 : 12
Container Version               : 9
Creator                         : Adobe Illustrator(R) 12.0
For                             : w xf, SMRDN
Bounding Box                    : -1309 140 1954 654
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M9HMOV001

Navigation menu