Samsung Electronics Co AIM-D00 DMS ( DATA MANAGEMENT SERVER) User Manual USERS MANUAL

Samsung Electronics Co Ltd DMS ( DATA MANAGEMENT SERVER) USERS MANUAL

USERS MANUAL

 - SEC-SWC WB TMPL-002  Ver. 1.0 2005-05-27       DMS User Manual                             Copyright notice This document is Copyright © Samsung Electronics, Co. – all rights reserved.  Copyright © 1999-2002 Samsung Electronics Co., Ltd.
DMS User Manual Version 1.0 Software Center, Samsung Electronics Co., Ltd.     2Table of Contents 1. GENERAL DESCRIPTION ..........................................................................................................3 1.1. DMS System Feature........................................................................................................3 1.1.1. System Establishment Environment .........................................................................3 1.2. Introduction of DMS Function .........................................................................................3 1.2.1. DMS Main Function.................................................................................................3 1.2.2. Console Function......................................................................................................4 1.2.3. Web Fuction .............................................................................................................4 2. DMS INSTALLATION................................................................................................................5 2.1. Prapration of the installation.............................................................................................5 2.1.1. Confirmation of the package.....................................................................................5 2.1.2. Check list before the installation...............................................................................5 2.1.3. Software Requirements.............................................................................................5 2.2. Installation ........................................................................................................................6 2.2.1. DMS Interface ..........................................................................................................6 2.2.2. DMS Connection ......................................................................................................8 2.3. Check list after installation ...............................................................................................9
 Software Center, Samsung Electronics Co., Ltd. 3   1. General Description 1.1. DMS System Feature 1.1.1. System Establishment Environment   1.2. Introduction of DMS Function 1.2.1. DMS Main Function 1) Wink 2) Tracking 3) DVM Monitoring/Controll 4) Fault/Error History Monitoring 5) DVM item inquiry / setting 6) Environment setting 7) DI / DO 8) Schedule setting / inquiry / execution 9) Power division setting / inquiry / data saving 10) Peak power control / setting / inquiry 11) Joint between the DMS’ Peak power control information
DMS User Manual Version 1.0 Software Center, Samsung Electronics Co., Ltd. 4   12) Information inquiry / settion of the demand controller 1.2.2. Console Function 13) Network information inquiry / setting 14) Information inquiry / setting of the service server 15) Inquiry / setting of the data 16) Inquiry of tracking information / Execution of tracking 17) Setting of DMS cryptograph 18) Master DMS inquiry / setting 19) Inquiry / initialize of the setting information priority order 20) DMS rebooting  1.2.3. Web Function 1) Login 2) Monitoring / contorling 3) Inquiry of the defect history 4) Set / inquiry of the schedule setting 5) Set / inquiry of the peak power   6) Set / inquiry of the power division 7) Set / inquiry of the system circumstance 8) Tracking 9) User management
 Software Center, Samsung Electronics Co., Ltd. 5   2. DMS Installation   2.1. Prapration of the installation 2.1.1. Confirmation of the package    DMS Case(UM 32009L) 1SET / pannel 2EA  DMS Main Board, Sub Board, Cable  Serial Cable 1EA  Power Cable 1EA  Ethernet Cable 1EA    2.1.2. Check list before the installation   Confirmation of the CAUR’ s operation DMS control the DVM System Air conditioner through controlling the CAUR. So, DMS can not control the air conditioner if the communication between the CAUR and outdoor equipments operates normally. And if CAUR can not detect the outdoor equipments, DMS can not detect the outdoor equipments and indoor equipments. So DMS must detect all outdoor and indoor equipments and confirm of the normal communication.  Confirmation of the PC serial port’ s normal operation If you want to use the console function, serial port’ s normal operation is necessary. So, confirm that serial port is operating normally.  Comfirmation of the operation LAN Because DMS communicate with upper controller through TCP/IP, normal operation of the LAN is necessary. If network is not working, you only can use console function. 2.1.3. Software Requirements   DMS can be set by console and web. It is necessary software requirements of below to do normally.  - Serial program to connect the console(Windows’ hyperterminal) - Java Runtime Environment 1.3.1 - Internet Explore 6.0
   2.2. Installation 2.2.1. DMS Interface               DI DO Reset PowerEthernet RS-485 SerialLED PowerDO DI Reset Ethernet RS-485 Serial
DMS User Manual Version 1.0 Software Center, Samsung Electronics Co., Ltd. 7   Item Contents Power  Supply the power. Reset  Used in system reset. DI  Connected to switch to create signal. DO  Control the on/off of the relay. Ethernet  Connected to i-MFC, S-Net and Service Server though LAN cable RS-485  Connected to CAUR, outdoor equipment and indoor equipment through coaxial cable. And then DMS collect the data and control through this. Serial  Used Version Upgrade and checking the defect. LED Display the system status.   Power – Checking the system on / off CPU Alive – Checking the system’s normal operation nLinked / nLanLED – Checking the Ethernet’s connections and operation Tx Data / Rx Data – Checking the RS-485’s status DI 1/2 – Checking the DI’s operation DO 1/2 – Checking the DO’s operation
DMS User Manual Version 1.0 Software Center, Samsung Electronics Co., Ltd. 8   2.2.2. DMS Connection   1) Power : Connect to AC Power through power cable. 2) DI : Connect to external switch. Be careful of +, - sign. 3) DO : Connect to external relay. Becareful of +, - sign. 4) Ethernet : Connect to LAN Cable. 5) RS-485 : Connect to CAUR. Be careful of C1, C2 sign.      DI DO PowerEthernet RS-485 Back sideCaur
DMS User Manual Version 1.0 Software Center, Samsung Electronics Co., Ltd. 9   2.3. Check list after installation Check the LED status displayed on the case after all connection is cleared.  LED name  Contents Power  If the power is supplied, this LED is turn on. Initial state is off. CPU Alive  If the CPU is alive, this LED is twinkling Initial state is off. nLinked  If LAN cable is connected, this LED is turn on. Initial state is off.   nLanLED  If data reception/transmition is occurred through LAN cable, this LED is turn on. Initial state is off. Tx Data  If data transmition is occurred through coaxial cable, this LED is turn on. Initial state is off. Rx Data  If data reception is occurred through coaxial cable, this LED is turn on. Initial state is off. DI 1 / 2  If external switch is pressed, this LED is turn on. Initial state is off. DO 1  Checking the status of indoor equipment. If one of the indoor equipments is turn on, then, this LED is turn on.   Initial state is off. DO 2  Checking the status of indoor equipment. If one of the indoor equipments have a defect, LED is turn on.   Initial state is off.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION   IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY   NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST     ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT   MAY CAUSE UNDESIRED OPERATION.  NOTE:    THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.  SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation.    This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help

Navigation menu